Loading...
HomeMy WebLinkAboutpitkin.eh.246315400007 (2003)Document Layout (From Most Recent to Oldest Permit) Permit Application Log Sheet/Notes & Photos Communications As -built Design Engineer Design Soil Information Floor Plans Water Permit & Information Land Use Approvals Second System on property Third System etc (All relevant older documents in the same order as above) (A red sticker will be placed on both sides of the file tab when doc. is scanned) Pitkin County Environmental Health Department Permit for an Individual Sewage Disposal System 0405 Castle Creek Road, Suite 10, Aspen, Colorado 81611 Phone 970-920-5070 / FAX 970-920-5077 Permit # 03048 Parcel ID # Type of permit 2463-154-00-007 New( ) Repair( x ) Addition/Remodel to House( ) Name of Owner Kearns Kelly Street Address 0638 N. Thomas Road Property legal description Size of lot 1.5 acres Water source Privates wall # of bedrooms in house 4 Caretaker unit N/a # of bedrooms in caretaker unit Designed for what # rooms (list) Designed by Mailing Address Perc rate 7 Total square footage of the house 3500 sq ft # of offices, lofts & similar sized rooms in house Total square footage of the caretaker unit # of offices, lofts & similar sized rooms in caretaker unit 4 bedrooms Permit information Dave Powell, Timberline Engineering Pr) Rnv 931 r:arhnnriale C0 81623 Profile hole depth 8 ft Depth to groundwater or bedrock Minimum Septic tank capacity 1750 -using existing 1500 Minimum Absorption area Comments Greater than 8 ft 370 w/ 50% reduction Septic permit approved per compliance with the engineer design and specifications dated August 6, 2003. Any changes must be approved by this department and the design engineer prior to them being made. Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin County ISDS regulations. There must be a minimum 132 foot setback between the wells and the field. There must also be a minimum 82 foot setback between the ditch and the field. These distances must be confirmed. This system will be using the existing 1500 gallon tank pending the engineer's confirmation of structural integrity. An effluent filter must be added to the outlet. The effluent will be distributed by serial distribution with 24 EQ -36 Infiltrator chambers. This department does not endorse any brand of products. This permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an as -built letter to this department. This department must also be called for an inspection with a minimum of 48 hours advanced notice. Permit approved by: Date: 2� Plans and specifications of the proposed individual sewage disposal system have been reviewed and are considered satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was issued unless system construction has commenced or an extension has been approved in writing by the Department. As -built drawingsust be Installer: this permit before the final approval will be issued. (`�, Final apploval Date:Abol) ow 000001 Aug 03 O 1 : 44p T i �r` -r� 1 i rte Engineering 970 963 9003 'Jul C -L ua u�:uua in 4n tnv. nea!rn i���cu-amurI PITKIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT APPLICATION FOR IN,DNI®UAL SEWAGE DISPOSAL SYSTEM 0405 Castle Creek Road, Suite 10, Aspen Colorado 8161.1 Phone (970; 9201-5770 Fax (870) 920-5077 Name of OWNERft-c Owner's klailing Addras � �j� Iv ��/UdiM3S -1--Va l9 City, State zip -- - �A�✓b 1t1!Ldle�Q_ 91(1122,e3 s., i S ness Phori@_ l t dome Pur �'G �j iDr3 O YI�I oil B �c1 pY ► S , v�-e >�� Primary Conw%, �1 connmunieaition regarding tlwis permit will go through this person) Name OwlK� Contact Mailing Address.__ Swvness Phone - _ � Gell Phone Fax,,, 'fw�rns t Address: ' Parcel !D il (available fmm assessors office + 0t 92G-5150 ®r at ww„ vt,Qitkirta. r Z 1 3 f 45 Stfeet audrr ss :;f property N, 1 V vv\A s C -C-,? _d Legal Size of lot. Iii _ acre, Total square feet of tlti�t.i; ``7.'��0__ - C W_ iv�tty rY of oedrx{r;s t 'r: i a o :,i rause -- .:�i�iaker t>n�i: Attact?Fd 1 ) t3etaGhed ( ) c" (potelntialLyl unit Perm it is for: New Home (Repair due to hit uE;x) _ RemarleUAddition ( j.�- Emergency use V1iatef: Private weil (x) Ser >g ( } Strea n ( ) C:ornrminity'Pubiic ltiater 3ystet" ( } I If co tttrur,ity system: Name of system The lee for a !SDS application i3 $600 for a permit that lal..es 6 hour- or les:; tar the department to approve. If approval takes ,cnger Tran 6 he s, a rate of $10Q per hour Will be charged The maximum fee is $1000. The basic fee of $600 is due at the tirree of apptication. T'he remainder, if any, will be due in rive eyes: first. at the time of Lsswance of the ISDS permit; secwid, before final approval of the ISIDS perni'. pplication for an irdivid;;a; Sewage disposal sysiterii is hereby submitted. l hereby certify that the above information is true and accurate jnd that i have provided true and accurate information on locations of all existing and proposed wells, contour intervals, buildings, property lines, ditches, slopes, waterlines, springs, suci; ; or irrigation Eines, drinking water cisterns, drain files, irr!gation ditches, takes, water courses, streams, fioodplains, dry gulches, and existing septic systems l hereby certify that any such features not shown on attached site strap are not present- issuance of the permit does nct imply the apprcval of any other permit required for construction pursuant to Pitkin County codes. No consUtrtion may be undertaken unt all approvals and perrnits have been obtained. The Pitkin County Env:ronmer!al Health Department, Pb:fn County and employees of these agencies will be held harmiess should the individual sewage disposal system fail or malfunction. The permit to construct is issued on information submitted by the applicant or hislher repro, entatives. The owner assumes full responsibility in use of failure of the a;'stem. rattire ofpplicart Date `3 Req iced by Receipt # G:ti:sds48d ptic'isdsLipp RevOd0101doc 000002 L p.3 P. -t C PITKIN COUNTY ENVIRONMENTAL HEALTH & NATURAL RESOURCES DATE: 11/16/05 Send to: Kearns Kelly From: Alicia Gomez Fax Number: 963-7099 Phone Number: 920-5087 CC: Number of Pages, Including Cover: 2 CC Fax Number: ❑ URGENT ❑ REPLY ASAP ❑ PLEASE COMMENT ❑ PLEASE REVIEW 0 FOR YOUR INFORMATION COMMENTS: Septic Permit # 03048 for parcel 2463-154-00-007, owner Kelly, has been finalized. Please feel free to call 920-5070 if you have any questions. fax cover Pitkin County Environmental Health and Natural Resources 0405 Castle Creek Road Suite #10, Aspen, CO 81611 Phone (970) 920.5070 1 Fax (970) 920.5077 Web site www.aspenpitkin.com/depts/12/ 000001 Pitkin County Environmental Health Department Contact Log Sheet Name: Parcel I D#: Address: Date Person Spoken To Comments / Action to be Taken Initials Time 000005 TIM:10, II- 100 1IEto, IM, 01,I STRU C'II'Q.JRAL/CP,nL IBNcGH,,TEIERIiN G + CONTRACTING ♦ (CERTIFIED ENERGY DIESE G14 PROFESSIONAL September 1, 2005 Pitkin County Environmental Health 0405 Castle Creek Road, Suite 10 Aspen, Colorado 81611 Re: ISDS Installation Parcel ID #2463-154-00-007 0638 N. Thomas Road Kelly Residence Dear Environmental Health: The installation of the ISDS for the above residence has been completed and has been installed in accordance with applicable county specifications and the approved plan. Enclosed is the as -built drawing for the system. If you have any questions, please call me at 963-9869. Sincerel .�\D A David A. Lcuell, Reg. No. 2.1. RECEIVED SEP 0 ; 2005 PITKIN COUNTY ENVIRONMENTAL HEALTH 000001 I P.O. BOX 631 cCARB®iDAIL]E, CO. 81623 PHONE 970 963 9869 / FAX 970 963 9003 Kearns Kelly 638 North Thomas Road Carbondale, Colorado 8 Co Hepworth-Pawlak Geotechnical, Inc. 5020 County Road 154 Glenwood Springs, Colorado 81601 Phone: 970-945-7988 Fax: 970-945-8454 hpgeo@hpgeotech.com Job No. 103 334 Percolation Testing, Replacement Septic System, 638 North Thomas Road, Pitkin County, Colorado. Dear Mr. Kelly: As requested, Hepworth - Pawlak Geotechnical, Inc., performed percolation testing at the subject site. The testing was done in accordance with our agreement for professional services to you, dated May 21, 2003. A profile pit and three percolation holes were excavated at the locations shown on Figure 1. The test holes were dug in the bottom of shallow backhoe pits and were soaked by the client prior to our testing. The subsoils exposed in the percolation holes are similar to those exposed in the profile pit and consist of about'/2 foot of topsoil overlying slightly silty sandy gravel with cobbles and boulders to the pit depth of 8 feet. No free water was observed in the pits and the soils were slightly moist. Percolation testing was conducted on July 25, 2003, by a representative of Hepworth - Pawlak Geotechnical, Inc. The percolation test results are summarized on Table 1. The percolation test results indicate infiltration rates of 6 and 7 minutes per inch. Based on the subsurface conditions encountered and the percolation test results, the tested area should be suitable for a conventional infiltration septic disposal system. If you have any questions or need further assistance, please call our office. Sincerely, HEPWORTH - PAWLAK GEOT , INC. tPp0 � Jordy Z. Adamson, Jr.,S129707 � 1, Rev. By: SLP a.��.., 3 JG3 .••��a�' 0NA1 JZA/ksw SS�.EN attachments Figure 1 - Location of Percolation Test Holes Table 1 - Percolation Test Results cc: Timberline Engineering - Attn: Dave Powell 000008 m EASEMENT I EXISTING SHED i / Z.Z . �P / APPROXIMATE SCALE 1 " = 40' I 103 334 HEPWORTH—PAWLAK LOCATION OF PERCOLATION TEST HOLES Figure 1 GEOTECHNICAL, INC. 000009 JVORTH-PAWLAK GEOTECHN INC. TABLE 1 PERCOLATION TEST RESULTS JOB NO. 103 334 HOLE NO. HOLE DEPTH (INCHES) ! LENGTH OF INTERVAL (MIN) WATER DEPTH AT START OF INTERVAL (INCHES) WATER DEPTH AT END OF INTERVAL (INCHES) DROP IN WATER LEVEL (INCHES) AVERAGE PERCOLATION li RATE (MIN./INCH) P-1 32 10 water added 13 11 2 6 11 9 1/2 1 1/2 9 112 8 1 112 8 6 1/2 1 1/2 6 112 4 2 112 13 11 2 11 9 112 1 1/2 9 112 8 1 112 P-2 37 10 water added water added 8 5 112 2 1/2 7 5 1/2 4 1 112 9 8 1 8 6 1/2 1 1/2 6 1/2 5 1 1/2 5 3 1/2 1 1/2 7 5 112 1 1/2 5 1/2 4 1 1/2 P-3 27 10 water added 10 1/2 8 2 1/2 7 8 6 112 1 1/2 6 1/2 5 1 1/2 5 3 1/2 1 112 10 8 2 8 6 1/2 1 112 6 1/2 5 1 1/2 5 1 3 1/2 1 1/2 Note: Percolation test holes were dug in the bottom of backhoe pits and soaked by the client prior to our testing. Percolation tests were conducted on July 28, 2003. The average percolation rates were based on the last three readings of each test. 000010 . • ' A. Received by (Please Print Clearly) B. Date of Delivery ■ Complete items 1, 2, and 3. Also complete Delivery is desired. item 4 if Restricted ■ Print your name and address on the reverse C Sig, tyre Agent so t at we can return the card to you. this card to the back of the mailpiece, (/A X ❑ Addressee Ye ❑Yes ■ Attach oro permits. i the front if space p s delive a ss different from items below:No 0 If YES, enter delivery address G . Article Addressed to: / 1 O O O 01 1 AJ 3. Sef ice Type ress Mail Certified Exp ® Mail [3 Return Receipt for Merchandise CO [3Registered ❑ C.O.D. p ❑ Insured Mail C� iv 3 v 4. Restricted Delivery? Fee) ❑Yes Q. Arty . umber (Conv from service label) 7 0 0 2 0 510 0003 5497 18 71 102595-00-M-0952 PS Form 3811, July 1999 Domestic Return Receipt Pitkin County. '`'" `""' EnoifonmentalHealth November 2, 2004 Kearns Kelly 0638 N. Thomas Road Carbondale, CO 81623 Re: Kelly Residence Parcel ID # 2463-154-00-007 Dear Mr. Kelly: On June 2, 2004, a letter was sent to you and your engineer (Timberline Engineering), a copy of which is enclosed, stating that we still had not received an "As Built" letter from the engineer who designed the individual sewage disposal system for the fore mentioned property. . The "As ,Built" .letter should confirm that they observed the installation of the system as designed and any changes in the system must be noted in the letter or by a new set of plans. Without this, we have been unable to complete the processing of this permit. Therefore, we regret to inform you that a copy of this letter will be attached to the property deed indicating that there is an open issue with the property unless the "As Built" letter is received by November 16, 2004. - When Pitkin County Environmental Health receives documentation have beenmet, steps will be taken to reflect on your deed(s) that the property no longer pertain.. - Sincerely, , Matt Kuhn Pitkin County.Environmental Health cc: Dave Powell, Timberline Engineering 000012 0405 Castle Creek Road, Suite 10 Aspen, Colorado 816 1 (970) 920-5070 fax 920-5077 . ,www.pitkingoy.com l June 2, 2004 Kearns Kelly 0638 N. Thomas Rd Carbondale, CO 81623 RE: ISDS Permit Approval Dear Mr Kelly: This letter is to advise you that we have not been able to final the Individual Sewage Disposal System (ISDS) permit for the above stated residence/property. It is mandatory that this office receives an "As Built" letter from the engineer who designed the system. The letter will confirm that they observed the installation of the system as designed. Any changes to the system must be noted in the letter or by a new set of plans. We cannot sign the Certificate of Occupancy for this property without the "As Built" letter. This office must receive the "As Built" letter from the engineer no later than 30 days from the date of this letter. Please contact me with any questions. Thank you, in advance, for your help and co- operation in this matter. Sincerely, Erena Miller Administrative Assistant Pitkin County Environmental Health Department cc: Timberline Engineering 000013 000014 ASPEN/PITKIN EN—V _.ONMENTAL HEALTH DEPARTt._.:NT ISDS DESIGN CALCULATIONS Owner's Name Parcel ID # House Size (sq. ft.) (75 gpd, 100 gpd, or 130 gpd) 100 Number of Bedrooms in Main House 4 Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House Number of Bedrooms in Detached Caretaker unit Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit (If the caretaker unit is ATTACHED, treat as if part of main house.) Average Daily Waste Flow 800 State Review Required? no Perc Rate 7 (T) Design Flow (Q) = # potential bedrooms X 2 people/bedroom X gpd X 1.75 Q= 1400 Absorption Area (=Q/ 5 X SQRT perc rate) A = 740.81037 sq. ft. of absorption area required 48 gravelless chamber units without reduction # of Perc Holes Required: 3 1 in every soil type? Spaced uniformly over proposed area? A maximum 30% reduction is allowed for use of deep gravel or gravelless chambered system, only if the lot size and soil conditions are optimal. If a reduction is being proposed, describe why lot size and soil conditions are optimal: A = 518.56726 sq.ft. w/30% bed reduction 33 gravelless chamber units -�u0 g3 23.E = Z4 370.405184 sq.ft. w/ 50% trench reduction 24 gravelless chamber units Type of system: []Absorption trenches []Absorption bed [] Gravelless chambers []Dry well []Seepage Pit []Other (type) Minimum tank capacity 1750 gallons SETBACK FROM WELL � � s h # of feet = j 132 SETBACK FROM"'T\ , STREAM OR IRRIGATION DITCH # of feet = 82 SETBACK FROX4-DRY GULCH # of feet = 57 0 0 0 01 1 Printed on Recycled Paper ---- ---------- -- ------- ----------- ',w 3eir`c'St!'-`.-t+kw'r.--------------------------------- - - �a, 01920-5077 p. l i' i , f `:1 C' a 3:.. t..s E:.,.1 :fie ._,.44e.� •..� % LL j_-tfIU Peu-nit Application required: J.1 fl -,e ISDS is designed b\ the owner/budder, he/she must sign an a6;nojyledgment assuming full responsibility for costs delays incurred O cau,,'I of errinrs result'nb from his,/her lack of ki - ledge of the pertinent lF�:r�r?a+i,:,,>,_,r r, .properly design and build an SDS in conformance with <� - n_s: ,ronsibihty for costs Ot aela_,'s incur_ed because of errors res<z tip c- }ro � mfr lack of knowled e otl�C F�errirc�r:t R �ulat; ,.1, or . l' p c g S DI it -_. tLe tvt:il tzze -ail.ire toproperly erl - desi n and built �n'� �� .1 Regulation. 0,,,v ,er % udder Signature 000016 May 21 03 00:42a Timberline Engineering 970 963 9003 P.1 n oa vv w r: � -V -- - ------ 108 76 w, o. SPUT 90� FND kap WICAP L -S P3710. wmm CM jr lk- 16.30, S?VW ►At (rw-) STAIR / _ o 7Q q \ J aNE STORY cauc5lwY Nal c1 )ate ./ J N Affil V IMA MR ! A coo SPLIT RAI Frfiwt A Is y� / CSS �E 1G�11S CCWV.. PATIO i �* 410 �' ��'` AQQX k2,Z7 PAGE' 5.28 1.481 Acres Tf/O.il,1.S �• - � (SCNAltiESER-e � S i� WtCAP _Vvr RAN -55v7,42- aFry 1 a; r_a3 ,t4 MMP k Post -it" Fax Note 7671 Date � �sges► caws f +/ ,f` r • To � � From s' Ito, Go -Meet. Co. o� s V Phone # �} a� Phone # — 4 -7 �` Fax a.-7.)pax# f[(��i'C6fS 3 a,,{ 3 wad , n `C r-ivc C -i en n4�-f 000011 �, 3� _ ► (1'z)was Od - May 21 03 08:43a Timberline Engineering 970 963 9003 0 0 • - 000018 p.3 May 21 03 08:43a 000019 Timberline Engineering 970 963 9003 p•2 0 0 J n. a r0, A. CALCULATIONS FOR REPLACEMENT SYSTEM 1. PERCOLA77ON RATE = 7 MPI AVG. (H.P. GEOTECH JOB NO. 103 334) 2. DESIGN FLOW = 4 BEDROOMS X 2 X 100 X 1.75 = 1,400 GALLONS PER DAY (< 6,000 SF LIVING AREA) 3. EXISTING SEPTIC TANK CAPACITY = 1,500 GAL - 2 COMPARTMENT CONCRETE TANK VERIFY STRUCTURAL INTEGRITY OF EXISTING TANK, INSTALL "T's" PER SPECIFICATIONS AND INSTALL EFFLUENT FILTER PER SPECIFICATIONS 4. ABSORPTION =100 / 5N)y AREA ^ 112 = REQUIRED4F 5. INFILTRATOR TRENCH INSTALLATION (EQ 36): 741 SQ. F7 / 31.93 SQ.FT PER UNIT = 24 UNITS MIN. 24 UNITS * 8.4375 LF / UNIT = 203 LF OF TRENCH MINIMUM. INSTALL TRENCHES IN 100 MAXIMUM REACH LENGTHS (11 UNITS). 6. WELL SETBACK DISTANCE 100 + 8 * ((1400-1000)/100) = 132 FEET Z DITCH, STREAM AND POND SETBACK DISTANCE 50 + 8 * ((1400-1000)/100) = 82 FEET 8. WATERLINE SETBACK DISTANCE 10 FEET TO TANK, 25 FEET TO FIELD B. GENERAL NOTES / 1 THE INFILTRATOR TRENCHES SNATURAL GROUND (NOT INHALL FILL)BAND BACLEVELK( 0.1 FEET), ON MUST PROVIDE POSITIVE DRAINAGE AWAY FROM THE TRENCH SYSTEM, 2. REUSE EXISTING 1,500 SEPTIC TANK. VERIFY STRUCTURAL INTEGRITY OF EXISTING TANK, INSTALL "Ts" PER SPECIFICATIONS AND INSTALL EFFLUENT FILTER PER SPECIFICATIONS 3. THE PIPE FROM THE RESIDENCE TO THE TANK MUST BE INSTALLED AS FOLLOWS: THE PIPE MUST BE INSTALLED STRAIGHT IN ALIGNMENT AND GRADE. IF A CHANGE IN ALIGNMENT OR GRADE IS NECESSARY, A CLEANOUT WILL BE REQUIRED AT THE CHANGE. THE MINIMUM GRADE OF THE PIPE MUST BE 1/4" PER FOOT. THE PIPE MUST BE A MINIMUM OF ASTM 3034 PVC PIPE. A MINIMUM OF 1 CLEANOUT SHALL BE INSTALLED AT THE LOCATION WHERE THE PIPE LEAVES THE RESIDENCE. THE PIPE SHALL BE A MINIMUM OF 4" IN DIAMETER. 4. THE PIPE FROM THE SEPTIC TANK TO THE INFILTRATOR TRENCH SYSTEM MUST BE INSTALLED AS FOLLOWS: THE MINIMUM SLOPE OF THE LINE MUST BE 114- PER FOOT. THE PIPE SHALL BE A MINIMUM OF ASTM 3034 PVC PIPE. THE PIPE SHALL BE A MINIMUM OF 4" IN DIAMETER. 5. USE RISERS TO BRING THE SEPTIC TANK ACCESS WITHIN 6" OF FINAL GRADE. 6. ALL MATERIALS, INSTALLATION PRACTICES AND SETBACK REQUIREMENTS SHALL COMPLY WITH PITKIN COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS. Z INFILTRATOR COMPONENTS TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. 8. PROVIDE INSPECTION PORTS AT THE END OF EACH TRENCH. 9. PROVIDE EFFLUENT FILTER IN SEPTIC TANK OR EFFLUENT LINE TO FIELD. THIS DRAWING SHOWS ALL EXISTING WELLS WITHIN SETBACK DISTANCES (INCLUDING ON SURROUNDING PROPERTIES), CONTOUR INTERVALS, ALL PROPOSED AND EXISTING BUILDINGS, PROPERTY LINES, DITCHES, SLOPES OF GREATER THAN 15%, WATER LINES, SPRINKLER SYSTEMS, SPRINGS, SUCTION (IRRIGATION) LINES, DRINKING WATER CISTERNS, DRAIN TILES, IRRIGATION DITCHES, LAKES, PONDS, WATER COURSES, STREAMS, FLOODPLAINS, FLOODWAYS, DRY GULCHES, OR EXISTING SEPTIC SYSTEMS, AND ALL SUCH FEATURES ON NEIGHBORING PROPERTIES WITHIN SETBACKS. NOTE: WATERLINE CROSSINGS REQUIRE THAT THE DRINKING WATER OR WASTEWATER PIPE BE ENCASED FOR AT LEAST TEN (10) FEET OF EACH SIDE OF THE CROSSING OR PLACE WHERE: COMPONENTS ARE CLOSER THAN TEN (10') FEET. PIPE OF SCHEDULE 40 RATING OR BETTER MUST BE USED, OF SUFFICIENT DIAMETER TO EASILY SLIDE OVER AND COMPLETELY ENCASE THE LINE. RIGID END CAPS OF AT LEAST SCHEDULE 40 RATING MUST BE GLUED OR SECURED IN A WATERTIGHT FASHION TO THE ENDS OF THE ENCASEMENT PIPE. THERE MUST BE A HOLE OF SUFFICIENT SIZE TO ACCOMMODATE THE PIPE IN THE LOWERMOST SECTION OF THE RIGID CAP SO THAT THE CONVEYANCE PIPE RESTS ON THE BOTTOM OF THE ENCASEMENT PIPE. THE AREA IN WHICH THE PIPE PASSES THROUGH THE ENDCAPS MUST BE SEALED WITH AN APPROVED UNDERGROUND SEALANT COMPATIBLE WITH THE PIPING USED. PLAN 'C TEE INSTALLED TO _ ISLE FROM MANHOLE 6 IN. MAX. BACK FILL OVER OPENING COVER OF MANHOLE. SECTION NOTIFY ENGINEER OF HIGH WATER TABLE BEFORE FINAL INSTALLATION OF TANK OR LINE CONNECTIONS TO TANK. SEPTIC TANK DETAIL NOT TO SCALE NATURAL BACKFILL EQUALIZER 36 UNIT 12" MIN COVER N 65"06'00 -Ill ll1=1J1—ll1-1 NATURAL GROUND 22" EQ36 TRENCH DETAIL NOT TO SCALE I r � ' ' WATER WE 30 CONC. ET. WAIL v 4 1 FIVO REBAR W/C l.s. #15710 � 0 �5 RR B S 308'26" W, G AJLL JOET411 _.2 SPLIT Rm \ENCE FND REBAR W/CAP LS. ,415710, WITNESS COR. BEARS N 645753" W, 215' �t'2s S 56001'55" if �\ �r 16.30 i STONE WALL (TYR) FND ` BEAAS SrAIR 53.0 o \ \ ONE STORY NOOS51. °)4 ,WOOD FRAME N ONE SFRAMtl A5 ROA \ A.D.U. N m CONC. °638 NOR GRAIL WATER -RV�\ l ' f W ( UNG �� SPLIT RAIL FES .. L.P 4� :. ti/ g o �° , ,� , GALLON coroc P ` o 2 -COMPARTMENT R ./� 93 CONC. SEPTIC TANK SrSE NOT 1 yy / fgfGl� �h� k0 N p� 11 / INFILTRATOR ENCHES: / THOJfAS CR, 203 LF ( INFILTRATOR UNITS) (SCHHUESER-COR, 11 UNITS t,N F)R5T,2 TRENCHES, / STP_ A. 2 IN ETHIRD. - v., f N0 RE6'AR W/CAP SPLIT F NJLLEG LE BEAK'S S 55'0742" W, 1:03 IN FALL INSPECTION PORTS ALL TRENCH ENDS / ANSFM PIPES TO BE FOUNDED ATIVE SOILS OR BEDDED IN p �• `1 1,3/4"'SCREENED ROCK. 109 �vFND !(£BAR W/CAP + S. )/15710 SES' fJET4'fl. l q�e GRAPHIC SCA. gy 30 0 13 30 60 0 yo ( IN FEET ) FiVD REBAR W/CA 1 inch = 30 ft P LS 415710 7 r nnn �L.nT DL.rT/`IJ.VA AY SCALE: V = 30' COPYRIGHT `Z M N �g w x f O 1�1 W Q1 P'oo Qd w � a w UPPER EXTENSIOV OF INLET U� M � AND EXIT 'TEES SHALL BE oD wQ�z�� WITHIN I IN. OF TOP OF TANK. pUHO. INSTALL OUTLET FILTER IN TANK OR � a U BETWEEN TANK AND FIELD, w oc x 14' INVERT TO BOTTOM OF - EXTENSION J x :E 865 rlWDER, ' x -Ill ll1=1J1—ll1-1 NATURAL GROUND 22" EQ36 TRENCH DETAIL NOT TO SCALE I r � ' ' WATER WE 30 CONC. ET. WAIL v 4 1 FIVO REBAR W/C l.s. #15710 � 0 �5 RR B S 308'26" W, G AJLL JOET411 _.2 SPLIT Rm \ENCE FND REBAR W/CAP LS. ,415710, WITNESS COR. BEARS N 645753" W, 215' �t'2s S 56001'55" if �\ �r 16.30 i STONE WALL (TYR) FND ` BEAAS SrAIR 53.0 o \ \ ONE STORY NOOS51. °)4 ,WOOD FRAME N ONE SFRAMtl A5 ROA \ A.D.U. N m CONC. °638 NOR GRAIL WATER -RV�\ l ' f W ( UNG �� SPLIT RAIL FES .. L.P 4� :. ti/ g o �° , ,� , GALLON coroc P ` o 2 -COMPARTMENT R ./� 93 CONC. SEPTIC TANK SrSE NOT 1 yy / fgfGl� �h� k0 N p� 11 / INFILTRATOR ENCHES: / THOJfAS CR, 203 LF ( INFILTRATOR UNITS) (SCHHUESER-COR, 11 UNITS t,N F)R5T,2 TRENCHES, / STP_ A. 2 IN ETHIRD. - v., f N0 RE6'AR W/CAP SPLIT F NJLLEG LE BEAK'S S 55'0742" W, 1:03 IN FALL INSPECTION PORTS ALL TRENCH ENDS / ANSFM PIPES TO BE FOUNDED ATIVE SOILS OR BEDDED IN p �• `1 1,3/4"'SCREENED ROCK. 109 �vFND !(£BAR W/CAP + S. )/15710 SES' fJET4'fl. l q�e GRAPHIC SCA. gy 30 0 13 30 60 0 yo ( IN FEET ) FiVD REBAR W/CA 1 inch = 30 ft P LS 415710 7 r nnn �L.nT DL.rT/`IJ.VA AY SCALE: V = 30' COPYRIGHT C: L i `Z M N �g w � M Ct O 1�1 W Q1 P'oo Qd w � a w r� 00 xa U� M � oD wQ�z�� �Z pUHO. C: L i U Ct P'oo W � a HO oD wQ�z�� pUHO. � a U w oc M O J DATE 08/06/03 REVISIONS SCALE AS SHOWN DRAWING ISDS PLAN NOTES and DETAILS SHEET 000020 A. CALCULATIONS FOR REPLACEMENT SYSTEM 1. PERCOLATION RATE = 7 MPI AVG. (H.P. GEOTECH JOB NO. 103 334) 2, DESIGN FLOW = 4 BEDROOMS X 2 X 100 X 1.75 = 1,400 GALLONS PER DAY (< 6,000 SF LIVING AREA) 3. EXISTING SEPTIC TANK CAPACITY = 1,500 GAL - 2 COMPARTMENT CONCRETE TANK VERIFY STRUCTURAL INTEGRITY OF EXISTING TANK, INSTALL "T's" PER SPECIFICATIONS AND INSTALL EFFLUENT FILTER PER SPECIFICATIONS 4. ABSORPTION (P1400 TRENCH 5 AREA R 1% =741 REQUIRED F 5. INFILTRATOR TRENCH INSTALLATION (EQ 36): 741 SQ. FT. / 31.93 SQ.FT. PER UNIT = 24 UNITS MIN. 24 UNITS * 8.4375 LF / UNIT = 203 LF OF TRENCH MINIMUM. INSTALL TRENCHES IN 100 MAXIMUM REACH LENGTHS (11 UNITS). 6. WELL SETBACK DISTANCE 100 + 8 * ((1400-1000)/100) = 132 FEET 7. DITCH, STREAM AND POND SETBACK DISTANCE 50 + 8 * ((1400-1000)/100) = 82 FEET 8. WATERLINE SETBACK DISTANCE 10 FEET TO TANK, 25 FEET TO FIELD B. GENERAL NOTES 1. ONE ENATURAL GROUND INFILTRATOR PNOT INHFILL) AHES SAL ND BACKILL 0.1 FEET), MUST PROVIDE POSITIV DRAINAGE AWAY FROM THE TRENCH SYSTEM. 2. REUSE EXISTING 1,500 SEPTIC TANK. VERIFY STRUCTURAL INTEGRITY OF EXISTING TANK, INSTALL "T's" PER SPECIFICATIONS AND INSTALL EFFLUENT FILTER PER SPECIFICATIONS 3. THE PIPE FROM THE RESIDENCE TO THE TANK MUST BE INSTALLED AS FOLLOWS: THE PIPE MUST BE INSTALLED STRAIGHT IN ALIGNMENT AND GRADE. IF A CHANGE IN ALIGNMENT OR GRADE IS NECESSARY, A CLEANOUT WILL BE REQUIRED AT THE CHANGE. THE MINIMUM GRADE OF THE PIPE MUST BE 1/4" PER FOOT. THE PIPE MUST BE A MINIMUM OF ASTM 3034 PVC PIPE. A MINIMUM OF 1 CLEANOUT SHALL BE INSTALLED AT THE LOCATION WHERE THE PIPE LEAVES THE RESIDENCE. THE PIPE SHALL BE A MINIMUM OF 4" IN DIAMETER. 4. THE PIPE FROM THE SEPTIC TANK TO THE INFILTRATOR TRENCH SYSTEM MUST BE INSTALLED AS FOLLOWS: THE MINIMUM SLOPE OF THE LINE MUST BE 1/4" PER FOOT. THE PIPE SHALL BE A MINIMUM OF ASTM 30334 PVC PIPE. THE PIPE SHALL BE A MINIMUM OF 4" IN DIAMETER. 5. USE RISERS TO BRING THE SEPTIC TANK ACCESS WITHIN 6" OF FINAL GRADE. 6. ALL MATERIALS, INSTALLATION PRACTICES AND SETBACK REQUIREMENTS SHALL COMPLY WITH PITKIN COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS. 7. INFILTRATOR COMPONENTS TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. 8. PROVIDE INSPECTION PORTS AT THE END OF EACH TRENCH. 9. PROVIDE EFFLUENT FILTER IN SEPTIC TANK OR EFFLUENT LINE TO FIELD. THIS DRAWING SHOWS ALL EXISTING WELLS WITHIN SETBACK DISTANCES (INCLUDING ON SURROUNDING PROPERTIES), CONTOUR INTERVALS, ALL PROPOSED AND EXISTING BUILDINGS, PROPERTY LINES, DITCHES, SLOPES OF GREATER THAN 157, WATER LINES, SPRINKLER SYSTEMS, SPRINGS, SUCTION (IRRIGATION) LINES, DRINKING WATER CISTERNS, DRAIN TILES, IRRIGATION DITCHES, LAKES, PONDS, WATER COURSES, STREAMS, FLOODPLAINS, FLOODWAYS, DRY GULCHES, OR EXISTING SEPTIC SYSTEMS, AND ALL SUCH FEATURES ON NEIGHBORING PROPERTIES WITHIN SETBACKS, NOTE: WATERLINE CROSSINGS REQUIRE THAT THE DRINKING WATER OR WASTEWATER PIPE BE ENCASED FOR AT LEAST TEN (10) FEET OF EACH SIDE OF THE CROSSING OR PLACE WHERE COMPONENTS ARE CLOSER THAN TEN (10') FEET. PIPE OF SCHEDULE 40 RATING OR BETTER MUST BE USED, OF SUFFICIENT DIAMETER TO EASILY SLIDE OVER AND COMPLETELY ENCASE THE LINE. RIGID END CAPS OF AT LEAST SCHEDULE 40 RATING MUST BE GLUED OR SECURED IN A WATERTIGHT FASHION TO THE ENDS OF THE ENCASEMENT PIPE. THERE MUST BE A HOLE OF SUFFICIENT SIZE TO ACCOMMODATE THE PIPE IN THE LOWERMOST SECTION OF THE RIGID CAP SO THAT THE CONVEYANCE PIPE RESTS ON THE BOTTOM OF THE ENCASEMENT PIPE. THE AREA IN WHICH THE PIPE PASSES THROUGH THE ENDCAPS MUST BE SEALED WITH AN APPROVED UNDERGROUND SEALANT COMPATIBLE WITH THE PIPING USED. PLAN 'C TEE INSTALLED TO ISLE FROM MANHOLE 6 IN. MAX, BACK FILL OVER OPENING COVER OF MANHOLE, FLUID SECTION BEFORE FINAL INSTALLARON OFTANKH OR LINE CONNECTIONS TO TANK. SEPTIC TANK DETAIL NOT TO SCALE NATURAL BACKFILL Amil �� ����11=1I I�IIII EQUALIZER 36 UNIT 7 12 MIN. COVER IIA NATURAL GROUND —J 11 17111-1; 22" UPPER EXTENSION OF INLET AND EXIT 'TEE'S SHALL BE MTHIN I IN. OF TOP OF TANK. INSTALL OUTLET FILTER IN TANK OR BETWEEN TANK AND FIELD. 14' INVERT TO BOTTOM OF EXTENSION EQ36 TRENCH DETAIL NOT TO SCALE /V 65°06'00" —� 34.13' ( x I I' 1 x FND REBAR W/C % L.S. 115710 � � 0 D SREAR o B S 30826" If 0. SPLIT RAIL EN( WATER WE Ac Ik STONE WALL (rYP.) STAIR N 30. 53.0 IY1 oE wall TORY NCDNST- I NE 5 AME OMA5 y0y000ORTH 1N (0638 f wki�� ,SEE jMF- Ill .2 FND REBAR W/CAP L.S. ,/'15710, W77NESS COR, BEARS N 64 57 53" W, 215' S 56°01'55" IF 16.30' ONE STORY + \ \ WOOD FRAME \ A. D.1! WA7ER WELL &�\ SRA WATER SERV. FND BEAR �o AT70 / UNC SPUr RAIL FE94et L. P. L'e CONC.. P 0 o GALLON \ R s 2 -COMPARTMENT CONC. SEPTIC TANK + ! SEe NOT -es j e o / 5" 5 6 INFILTRATORITRENCHES• / THOTIAS CR 203 LF (�74 INFILTRATOR UNITS) / (SCwt UESE)?-00R 11 UNITS''tN FIRST.2 TRENCHES, STR4. 2 IN% THE'THIRD. + fND REBAR W/CAP / OLLEf' L£ BEAPS S 5517742' If 1.03 '� IN ALL INSPECTION PORTS ALL TRENCH ENDS / ANSFER PIPES TO BE FOUNDED NATIVE SOILS OR BEDDED IN p SCREENED ROCK. 6 +D WEBAR W/CAP L.57/'157)0 + / 'D1��� / b � / i -ASYE OF -r fL 1 mo 0 1 0 tiP \FND REBAR W/CA P L.S. ,/15710 f nnn ID/+T AL+AT/'U.UAAY GRAPHIC SCA. 30 0 15 30 60 ( IN FEET ) 1 inch = 30 ft SCALE: FT = 301 COPYRIGHT DRAWN BY DA zM N txoc o Ute° ctt 0 QQ w W >--� 0 �oc �W F Um z r� M � W WQHZu o0 �x z° � a DRAWN BY DA DATE 08/06/03 /REVISIONS ==�ZWN DRAWING ISDS PLAN NOTES and DETAILS SHEET nnnn7l uuww" Ute° ctt Wcf� W >--� 0 Q� oQo� z r� WQHZu z° W 00 M DATE 08/06/03 /REVISIONS ==�ZWN DRAWING ISDS PLAN NOTES and DETAILS SHEET nnnn7l uuww"