Loading...
HomeMy WebLinkAboutpitkin.eh.246334102042 (1998)Document Layout (From Most Recent to Oldest Permit) Permit Application Log Sheet/Notes & Photos Communications As -built Design Engineer Design Soil Information Water Permit & Information Second System on property Third System etc. Floor Plans Please see Building and Land Use Approvals Files for additional information. R( +n/Pitkin Environmental Heak..i Depr- ont Pe`N,1a for an individual Sewage Disposal „-Otem 130 S. Galena St. Aspen, Colorado 81611 Phone 970-920-5070 / FAX 970-920-5197 Permit #D Parcel ID #(3 Type of permit e1<2 (Jame of Owner� J �N Street Address PaQ0>'g 5- ce;'o- Property legal description %44 /v. gel/ C/' —AV ' �!✓��`��lp, �/� �`� y3 Size of lot ' - Total square footage of the house Water source t' 4 C�rh male C`7 # of bedrooms in house # of offices, lofts & similar sized rooms in house Caretaker unit A) 1,4 Total square footage of the caretaker unit iUIIif # of bedrooms in caretaker unit y1 # of offices, lofts & similar sized rooms in caretaker unit Designed for what #bedrooms L{- �f^AYrls Permit information Designed by So P/ Fi�ru�� i2'� �4NG/�z �J Mailing Address Sp groundwater or bedrock to Z lei S Perc rate 60 Profile hole depth �_ Depth P 9 Septic tank capacity 2"2-00 Q41101-) Absorption area 27/0 Ar i) ire =5l1s n�cysT 6 ° iN3TQ/!gid wi�,:v s�r6 s d�fi iti 1 N e4�f-� a_r_ %leis 7-;l`/97&, 2,)Tlvo Snzil/er SB�j7c7�ir�los,�a//icy Z2oo��!/o.vS,isac/B pp_v vi din� The // Date: _ , rte_ lL i� ,( �i S Permit approved by:. —Y Plans and specifications of the proposed individual sewage disposal system have been reviewed and are considered satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin icounty ISDS ssued unless e ' permit was system construction has commenced or anexte extension has n been approved w ting by the Department. As-built drawings must be included with this permit before the final approval will be issued. installer: Final inspection appy Val: ate: 52t�8 000001 c ASPEN/PI-1 J ENVIRONMENTAL HEALTH D' %RTMENT APPLICATION FOR INDIVIDUAL SEWAGE DISPuziAL SYSTEM 130 S. Galena St., Aspen Colorado 81611 Phone 970-920-5070/Fax 970-920-5039 &r 1LOA111 Name of OWNER r Owner's Mailing Address Business Phone: Home Phone:: ` 61 O Primary Contact Person (all communication regarding this permit will go through this person) Name Company ( / Contact Mailing Address Business Phone: Cell Phone: Fax : tJ✓ 3- S Parcel ID # (available from assessor's office -1 j j - / / _ -.D T at 920-5160 or at www.aspen.rcoMassessor n c fin/ i /Ln' Street address of property ! / I� \) %(' l ` ,rer r � '20,-A` ' Legal Description: Lot Block Filing Subdivision Size of lot: acres. Type of proposed structure: Size of bldg. envelope: Total square feet of house # of bedrooms in house <� *of offices, lofts & similar sized rooms in house Caretaker Unit: Attached ( ) Detached ( ) Total area(sq. ft.) of caretaker unit # of bedrooms in caretaker unit # of offices, lofts and similar size rooms of caretaker unit Permit is for: New Home( Repair due to failure ( ) Remodel/Addition ( ) Emergency use ( ) '. ) P Water: Private well ( ) Spring ( ) Stream ( ) Community/Public Water S stem / "` If community system: Name of system ` �b"04/"� The fee for a ISDS application is $330 for a permit that takes 6 hours or less for the department to approve. If approval takes longer than 6 hours, a rate of $55 per hour will be charged. The maximum fee is $1000. The basic fee of $330 is due at the time of application. The remainder, if any will be due in two stages: first, at the time of issuance of the ISDS permit; second, before final approval of the ISDS permit. Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information is true and accurate and that I have provided true and accurate information on locations of all existing and proposed wells, contour intervals, buildings, property lines, ditches, slopes, waterlines, springs, suction or irrigation lines, drinking water cisterns, drain tiles, irrigation ditches, lakes, watercourses, streams, floodplains, dry gulches, and existing septic systems. I hereby certify that any such features not shown on attached site map are not present. Issuance of the permit does not imply the approval of any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all approvals and permits have been obtained. The Aspen/Pitkin Environmental Health Department, Pitkin County and employees of these agencies will be held harmless should the individual sewage disposal system fail or malfunction. The permit to construct is issued on information submitted by the applicant or his/her representatives. The owner assumes full responsibility in case of failure of the system. Signature of applicant G (� Date J�LG c nnnnn,) Aspe Pitkin Environmental Health Department Contact Log Sheet H nnnnr,n Aspen / Pitkin Environmental Health Departmer , Contact Log Sheet 615f wlkStOtdir lhs.kw tHlte pl a leue[�iJoofite�-�prgetwd�{ 0�00[l 1 PJA Viet-. V --C— f Wwu I,- .Y --1 � i --a de 61 lug ivrPra►- r *JJ I+LTial.I�L:. d , � r 1 M -, TMR _ " i. , • cr r :- TMINI Wi MM"W's W, to �; "amu .:. ��.'- �.►.' �. � 615f wlkStOtdir lhs.kw tHlte pl a leue[�iJoofite�-�prgetwd�{ 0�00[l 1 PJA Viet-. V --C— f Wwu I,- .Y --1 � i --a de 61 lug ivrPra►- r *JJ Aspen / Pitkin Environmental Health Department Contact Log Sheet Flow, Parcel • • Address: • P Date PersonSpoken To • e Action to beTakenlip� 1111111111 - Eli MI � � - �aD� � ` YY lei ■ r � [ Jill Ili 51IJIM cue iiiiiiiijii ilii"i[�a • • � _ � �'�-�- Jill / l PIN W11,111,11111, won ��1 �� .. �4�I a ,:/ �i.•r_� 'r1.GY ;vim_ I I �L 000005 o� �c�k� will, corlcd►vwu� `N +� 6tt # d .- ,�_W)Oyii X a,_,l_ LO V C4J. W#_ ca.at�rvl 91vt Abpen / Pitkin Environmental Health Department Contact Log Sheet Name: Parcel ID#: Date t H -i .5 - 3c{(._ 7 Person Spoken To _ n Address: — Comments / Action to be Taken Initials ' 3�t "1 U'r Old ML h G c_ 1 A � C L L/1 G �` L G C v n I I I I I I Nancy Mackenzie Aspen/ Pitkin Environmental Health Department 130 Galena Street Aspen CO 81611 RE: Terry & Jean Mobley ISDS SE Job No. 98013.01 Dear Nancy: December 30, 1998 i ENVIROWE"1TAL-EALTti ASPEN / A;T N I apologize I didn't get this to you sooner. I field inspected and As -Built the ISDS for Terry & Jean this summer. The leach field was built the same as the plans except it was 11.5' from the North property line instead of 10' as shown on the plan. Two septic tanks were used instead of one as shown on the plans. A 1250 gallon tank 5'-2" from the house and a 1000 gallon tank 6 feet from the leach field were installed. Attached is a copy of the site plan with As -Built information on it. If you need any additional information or have any question please give me a call. Sincerely, SOPRIS ENGINEERING, LLC Yancy Nichol, P.E. Project Engineer cc Jean Mobley 502 Main Street • Suite A3 • Carbondale, CO 81623 • (970) 704-0311 • Fax (970) 704-0313 SopRis ENGINEERING • LLC civil consultants 000009 August 19, 1998 Jean & Terry Mobley P.O. Box 856 Carbondale, CO 81623 RE: ISDS at 114 N. Bill Creek Road Dear: Mr. & Mrs. Mobley: I have included an invoice for the four (4) additional hours this Department spent reviewing the application and inspections. The initial permit fee covers six (6) hours of review and inspections. This Department will not sign the final inspection approval until the following items are received: X. The $220.00 for the additional time spent on this permit. 2. The engineer's inspection letter. 3. The as built drawing on the installation. Please call this Department if you have any questions. Sincerely, Jannette Whitcomb, REHS Environmental Health Specialist 000010 ro w m CT 1 n ;000011 w rrHrrrrrrrrrrrrrrrr l� Irol G�l III H H r r r r r H r o 0 0 0 0 0 0 0 0 o b b b b b b b b 10 I m I W � I I 4444444444444444444444444444444ig a I w I 14+ I rt 4444444444444444444444444444444 01 N (D(D M M(D M M M M M M M M M M M M M M rf M M M M M M n M M n mmmmm(D (D mmmmmmmmm("Dm m (D (D m m m m m m (D (D m m ml I rt nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnl�l m mmmmmmmmmmmmmmmmmmmmmmmmmmmmmmml I •• r-YY-wY-Y-Y-Y-Y-Y-Y-Y•Y-Y-r-Y-wr-Y-r-Y-Y-Y-r-wwwY-Y-Y•Y- I m I rorororovrorororororororororororororororororororororororororol 1 R rt R R R rt R R R R R R R R rt R R R R R R R R rt rt R R R R R R 1 I I I I I I I I I I I r r r H r r r r r r H H Y r r r r H H H Y r 0 0 0 0 0 0 0 0 0 1 d I N N N r r r r r r H H H 0 0 0 0 0 0 0 0 0 0 b b b b b b b b b I N O O N r 0 0 0 0 0 0 0 N N N N N N O 0 0 0 W N r r r H 0 0 0 1 IP WIP IP 00101 VINW WmbW W WNrWNNrOHW W W WbW W I r rrrHHrrrrrrHrrrrrrrrrrrrrrrrrrl O b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b I b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b I O W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W I O I r H H r r r r r H H H H r r r r r r H H H r r 0 0 0 0 0 0 0 0 1 N N N N r r r r r r r H 0 0 0 0 0 0 0 0 0 0 0 b b b b b b b b I N r O O r 0 0 0 0 0 0 0 W N N N N N r O 0 0 0 N N N N N N N N 1 W 01 J W 01 b b b b b b b O J J J J J N J J J J W W W W W W W W I r r H Y r r r r r r r r H r r r r r r r r r H H r H H r H r r l b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b I b b b b b b b b b b b b b b b b b b b b b b b b b b b b b 1010 I W W W W W W W W WWW WWW W W WWW W W W W W W W W W W W W I aawwwwwwwawwwwwwwawaawaawwwwwaw < < < < < C C C C C < C < < < < < C C < < < < < < < < < < < C I r-wr-r-r•Y-r-Y-Y-Y-wY-r-r-r-r-r-r-wY-wr-w wY•r-r-r-www I r n w rt O n d fwi m lal O 1 m 1 R 1 d I 1 rt I m I n G ro ✓NNNJNJaF1F1 rT r'T r'T r'T FT 'T 'S'S5rT'S. I P- P•FT FF . I G G G G G G G G G G G G G G G G G F G C G G G G G G G G G G G 1 I m I w I n I R 0000000000000000000000000000000lMY- rHrrrrrrrrrHrrrrrrrrrrrrrrHHHrrlmO I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I MIS N IP IP IP iP IP IP IP IP IP IP IP IP IP IP IP IP IP W W W W W W W W W W W W W I m NWW0I IP IP IP IP IP IP IP IPWWNNNNbbbbbJJJ0101N VI VII MO O VIObwNrrrrHH W Obb W WHIPIP W W V1001PIP W N0 I m m NJ W W WO bIP IP W W W ONW W W N W0101WNJOOHObIP W I p rt to IP IP W 00 W W ObJ W V101N rrPrWmWIP W W b W ObJ W O I n w I m r - I H I I I I H rxH HHeK1K3b�HW4(1roH3xWt+7 romn3roxnmW 1 t] 1 >200 O>OmH MgmITJ Hmo7yxb MoC Gloom 1 m 1 L'J C7 zWnr rroo r Ct7W H. D< W roHK I m 1 n WHztnxrrmW rorWgDo7HMHro CCrzlroth 1 n I Oxo\HHSU'KH[>:JZ\WHCm q\ zIW C7 t+7 I M I ,'0 $N[+z[+JJZ-9 ZPd > WronH \UKHHK H 'T]I�<NDyOyH 'yyCI!4 n1 C m � W H Mit ZHW IIc I HW W[ zWHt-• I �yK .'CIW I C7 H(tlAHW H0In w 1 W\ OmW\H H ,3,W W W0 WW 10 1 UHHO H HMOW P7 QHHW H 0H0M 0 I 1 W W W H W W z W K n H m 0] r W W W I I tJ0 Wti W xW d ro r y I I W W tW7 W nD I-3 M N t7 H W [+ H b7 74 0 I 1 nH H NW W H R7 l7 I W HH WG n\ m �n Yr i W Pro ti H x Km z o i x7 H 7. W a W N I 1 C7 ED O IBJ N R1 I I m K C I I t•D I 1 M I I m W W W W W W W W W H W W W W W W W W W W W W W r W N r W W W W O W W W W W W W W W r W W W W W W W W W W W W W r W N VI W W W W UI 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn I I I I I I 1 1 I I I 0 1 Q I I R I I I I d I \ I nl 0 R m a n nGpoG �rt OH �] Z yO m�ro zR O G ro w w IT nRtrnw 11 ' 1 ' ro' Ip d+IPWWWWNr,mn,� H Ort r I ro 1 Obm�101 N,PWNr.,,M r r r r 1 k I bbbb1m1 r r a 0 p 11 O II � w 00k w n1 I bbbbla, bb O.mGrt it mrt IP1nm�1n1 �m,n1 Iwi�mn � ii �ro 4 i i m I 1 I , , 1 aY-nH I lOn 1 (]y]CC� f,] M 4444444441, i i nom z n b p. m P. I 444444444 I I I I I J•. II .. .. .. kzon r II m m m m m m m m m' 0 0 0 0 0 0 0 0 0 mmmmmmmmm 'R7 I I , 1 1 I 1 ltl II Y-Y-Y•Y'F"Y-W Y•Y�, m l I I 1 1 I I robrovrovrovrol 1 , , �, O II n rt R rt rt n n rt n 1 I , 1 1 I I I 0 0 11 o u 0 o o u 1 , oat I p n � o000oo0ooipi 1, ,, 1 1 n r n ApIPW W W WNr , O, 1 I , I 1 1 N N II 1 0r�a+Hwoo�7arH1 1 d, 101 10, I p I •• I rrrrrrrrr I R 1 PHI , Fj , bbbbbbbbb 1 m I , Y- 1 I Y- 1 1l0 I 1 bbbbl0bbbb I 1 W W, (O 1 H 1 {Q 1 , m, II 1 mmmmmmmmm I I UI VI , I r0101O 1 I I n, I 000000000 , ro t m 01 1 0 1 cJmiPm I m, , P7 , n 1 NAAIP IP IpW N N 1 0 1 O 0101 N OUIO 1 G, , m 1 II 1 0 0 0 0 0 0 0 0 0 0 0 0 0 1 O.1 0 0 0 0 1 ONNOOOrN01n, • • • 0000..... 1w, .... 1(0, • • IY-1. II 0000000000001 mq 00001 m l oo 1- 1 II CJ 1 O 0000000000001 rt0 0000 , R'y' 00 1 II 1 r r r r H r r r r w 1 1 I (j 1 I 11 I bbbb1010bbb 1 rt 1 1 O 0 1 0 1 1 II I b b b b b b b b b I m I 1 , O 1 m 11 1 m m m m m m m m m 1 1 , 1 G n I 1 1 " I o.aaaaaRRRInI rt w ii wwwaawaWyWpIln1 n i rt ' <C 1 0 1 x 11 01 r^G�Y^G�anYG�YnG�nGY�nn(w* ilOH G, i WtR" i am 1 ro 11 y 1 JJ�JMD 1 n ,u.< Iu.R , n n n 1 G G G G G G a w w I ay I G w Pro m II m 339, p Imrt Imffjj , ro n no rt'< , R'< , w H It H G At M I , 0 O 0 0 0 0 0 0 0 0 0 0 0 0 1 M, 0 0 0 0, 1 0 0, W rt II K rt R 1 0, , 0 1 1 rt H II 0 0 0 0 0 0 0 0 0 1 'p0 W. O 0 0 0 0 0 0 0 0 0 o o 0 1 R 1 00001 " 1 0 0 1 P. m It O H 1 r r r r H r r r r 1 m o 0 o o O o o o o o o o o o 1 m 1 a O o o, m, o o 1 O •• II 't7 o ' rrrrrr000 1 m 1 VIU I M I Uf IP WHU1N WbH WHW"Wwl" M m m ro 11 ro3 J U1 m v, a o rm 1 , , , , 1 , m H 11 w iP J N O VI W �P VI 1 0 w 0 W I 1 , 1 , R7 R H II 7. rt z Y -O mL,P-m n11 W p 0 G O rG it O 1 mmRm qq 1 In NWNNNriP NH 1 `M 1 IOOrN 1 z n m, 1 1 m (D 1 I m m m n [930707 OIOHH, m 1 b .ro , m 1 0\ O bit WlP mOlb iPrWWW 1 < 1 W l m, W�&O: L' , UI �l IP01 m, 1 L -JIM I 1 m 1 0 '101 -Q 0 rt•J w II O7 II HC" Hk , 0 , VI 000010 00(floNW OOOOOOOU100001 'fi I OUINO 1 1 00 1 rt 1 0 •J II am P-4 M kMz p7w 1 n I I .7 ,�7 1 z(9 7. dy mzn 07 , Y-, a7mzla7, O o Oo00aaa0000o 1 m 1 000000000000lm, 0000 , m , 0000,m, 001 3 001I .. .. .. .. H II H II 1 1 z�!: m z0 d0 1 R 1 k nm y' m 1 W, , , , 1 1 1 zzk ii I Mr c((7 1 0 1 1 1 1 1 1 1 11 1 [) n M H H 1 0 1 �0rok b o 1 I I I 1 1 u <z[��j I , H(n Lv Ea� 1 1 1 1 1 1 1 k m 11 n I H U.$ 0 11 I 1 1 1 , w 11 I n n I I I I I I I I n 1 ro H x I I , I I I , I I n , I r r r H N N N W W W W, 1 „ I 1 1 , 0] 1 O 1 I bOW iib NIP 01H W IP In , 1 H NW 1 1 1 , ',7 II 1 n 1 I bb�101PWbbIP V1bN I w 1 bNOr 1 w 1 , 1 II 1 O , I bmWWbUtb �lJbIPJ1 r1 O�ib01 r1 , , 07 11 , I VI UI UI UI VI VI OI U10000, 1 OV,NO 1 , , 1 � •00.00101 1 , 000000000000,01 00, 1 P. It I 1, o000000000001ml 0000,m, oo, I 3 n 1 , , 1 1 w u I 1 I I 1 1 •• 11 I n 1 O 1 I 1 I I 1 I�j I m I n I m I 1 1 w 1 W I w 11 1 1 , (91 k u I , 1 0 0, m 1 m n I wwHwwwwwwlgl oo,rt, w n I mwrwwmwww,31 ,Y-, n n 1 000000000,01 00131 •• n I o00000000,pl r n 0 0 0 0 0 0 0 0 0 1 rt 1 O b II b 11 ro o m n 'ao w1 o 11 l0 1 1 iJ 1 11 LCI M nnnnnnnnnl\1 11 M m fln1 n i H I j UnL. m / POLE ap r RISE IHC AREA f !• f) x a sEpnC r r ESLD o � P ANE 1 I yrj T K 1 O/ O 24' h4 C� 4' v hw QOM !u� V� 7 11 18• /. :.--V.:. a J i W y -- - 30 SE pox. 2a x . R C 6 �o / A7 cR JNE o 95 CRSS/ / j WdL1C iC �1AP x %CORAL JutY 21 S eW 1 ZAGTS / . - 7:'.00' •� / x 12- AR TACH UGH ' BRUSH/ 1 S� fi Vr THIS AhkEA1 / METAL S ' R f P�GJt /•.A WAP EEC . OU11FjC OF>_'BEARING Y C T BRUSH ,l `��0.Ofv°' N%C •jcq�, \O THIS EA 3 6 Jill REBAR C:AP . ~.. ' L.S..ICLEGABI E ,JoL :X80 /s c, <" 81A ELEVA"goN t040 4 f .7w ... ~ <:� : rt ' :;3. �is.L•'�;r`>.'a'.; �-:' - s�jx'• :� r •�T.M�4"ts�. •'`�-'•� ... _f .1- _ ... .. -4:_' Jean and Terry Mobley ISDS Design Recommendations May 20, 1998 Page 2 We recommend the surface of the field be seeded using a native seed mix available at seed stores. No landscaping or automatic sprinkler system is allowed over the field. Livestock should not be confined in the field area. Our design and recommendations are based upon data supplied to us by others. If subsurface or site conditions are found to be different from those described in this report, we should be notified to evaluate the effect it may have on the proposed ISDS. If the County Environmental Health Department requests changes or modifications to this design, we should be contacted to evaluate the effect on the ISDS. All construction shall be in accordance with the ISDS Regulations. If you have any questions, or need any additional information, please call. Sincerely, SOPRIS ENGINEERING, LLC Yancy Nichol, P.E. Project Engineer 000014 a Jean and Terry Mobley P.O. Box 856 Carbondale, CO 81623 RE: ISDS Design, New Home, 114 North Bill Creek Road, Pitkin County, Colorado SE Project No. 98013.01 Dear Mr. and Mrs. Mobley: 20, 1998 As you requested, we have reviewed the report by Hepworth Pawlak Geotechnical, Inc., dated May 6, 1998 under Job No. 197 575, in which they determined the average percolation was 60 minutes per inch for the new leach bed area. We also reviewed an improvement survey prepared by the Sexton Survey Co. dated October 10, 1997 under Job No. 97013, which shows the site conditions. It is our understanding the existing trailer house is to be removed and a new home with four bedrooms to be constructed. We have designed an individual sewage disposal system (ISDS) based upon the above-mentioned information fora fhve bedroom house. The site sloped from the east to west at a moderate slope of 10% to 15%. An existing sewage leach field is located approximately 10 feet north of an existing garage. This design was based upon a new leach field and the old field to be abandoned. The location of the proposed leach field is shown on the attached Exhibit A. The sewage load for a five bedroom home is 1,000 gallons per day (gpd). A peaking factor of 1.75 for design loading equals 1750 gpd. We recommend a standard seepage bed for the ISDS to be installed as shown on Exhibit A. Design Criteria: No. of bedrooms: 5 Loading - Q - 1000 gpd Percolation Rate - T - 60 minutes per inch Area - (1.75xQx4T)/5 Total Area - 2710 s.f. For bed specifications, see attached Exhibit B. Septic Tank: 30 hour retention required 1.25xl000x1.75=2187 gallon We recommend a 2200 gallon, two-compartment, pre -cast concrete septic tank and a distribution box to be installed to distribute effluent on both ends of the field. The dispersal gravel to be covered with a Mirafi 140n geotextile fabric or approved equal. 502 main street • suite A3 • carbondale, CO 81623 • (970) 704-0311 • fax (970) 704-0313 opRIS ENGINEERING • LLC civil consultants 00001E ASPEN/PITQ COMMUNITY DEVELOPMENTaEPARTMENT 130 South Galena Street Aspen, Colorado 81611 (970) 920-5090 FAX# (970) 920-5439 April 30, 1998 Terry & Jean Mobley P.O. Box 856 Carbondale, Colorado 81623 Re: Mobley Minor 1041 Hazard Review Case #P056-98 Dear Terry & Jean, The Planning staff has completed its preliminary review of the captioned application. We have determined that this application is complete. After a more detailed review of the submittal information, additional information specific to the application may be requested in order to adequately review and process the application. The planner in charge of the review will request the information from you directly. We have scheduled this application for review at a public hearing by the Pitkin County Hearing Officer on Thursday, June 11, 1998 at a meeting to begin at 10:00 a.m. in the Commissioners Meeting Room in the Courthouse. Should this date be inconvenient for you please contact me within 3 working days of the date of this letter. After that the agenda date will be considered final and changes to the schedule or tabling of the application will only be allowed for unavoidable technical problems. The Monday before the meeting date, we will call to inform you that a copy of the memo pertaining to the application is available at the Community Development Department. Please note that it is your responsibility to post the subject property with a sign within 15 days of the public hearing and to remove it from the property within one week following the hearing. Please submit the enclosed Affidavit of Notice by Posting as proof of compliance with the Code prior to or at the hearing. We have forwarded a copy of this application to the Colorado State Forest Service for referral comments. Please contact them directly at (970) 248-7325 to arrange for payment of their fees. Comments will not be released until payment is received. If you have any questions, please call Tamara Pregl, the planner assigned to your case, at 920-5103. Sincerely, Sharon Hirman Administrative Assistant 000016 C O HEI'WORTH-PAWLAK GEOTECHNICAL, INC. 502 iRoo d Springs, CO 8740I May 6, 1998 Fax 970 945-8454 y Phone 970 945-7988 Terry and lean Mobely 0114 North Bill Creek Road Job No. 197 575 Carbondale, Colorado 81623 Subject: Additional Percolation Testing for Leach Field Design, Proposed New Residence, 0114 North Bill Creek Road, Pitkin County, Colorado Dear Mr. & Mrs. Mobely: As requested, a representative of Hepworth-Pawlak Geotechnical, Inc. performed percolation testing at the subject site. The results of our work are presented in this report. We previously performed percolation testing of the northwest portion of the site reporting our findings on October 3, 1997, Job No. 197 575. A profile pit and three shallow backhoe pits had been excavated in an area about 100 feet northeast of the existing residence as shown on Fig. 1. The pits had been excavated and the shallow pits had reportedly been hand dug and pre-soaked by the client one day prior to our site visit. The subsoils observed in the profile pit consisted of about 'h foot of topsoil overlying clayey silty sand with gravel and scattered cobbles to the pit depth of 81h feet. No free water was encountered in the profile pit and the subsoils were moist. Percolation tests were performed in the, silty sand with gravels on May 4, 1998 by a representative of Hepworth-Pawlak Geotechnical, Inc. The testing was conducted in the bottom of the shallow backhoe pits that were about 3 feet deep. The percolation test results are summarized on Table I. The percolation test results indicate infiltration rates of 60 minutes per inch. The percolation rates were based on the last 3 readings of each test. Based on the subsurface conditions encountered and percolation test results, the tested site appears suitable for a conventional infiltration septic disposal system. If you have any questions, please call our office. Sincerely, HEPWORTH - David A. Young, Rev. By: DEH DAY/ksm attachment 32-216 O Q ZONAUF INC. cc: Sopris Engineering - Attn: Yancy Nichol 000017 APPROXIMATE SCALE 1' = 40' NORTH BILL CREEK ROAD LOT BOUNDARIES �_J EXISTING GA AQE_ - - 1010 1010 ---------------'-- \ PREVIOUS- - - - REVIOUS---- - - "-1 TEST EXISTING SITE RESIDENCE 1020 ��------------ 1030 - t - P 1 PROPOSED RESIDENCE 1040 -- 0 197 575 HEPWORTH - PAWLAK GEOTECHNICAL, INC. Q PROFILE \ 1 1020 PIT ■_ P 3 A% 1030 LOCATION OF PERCOLATION TEST HOLES I Fig. 1 HEPWORTH-PAWLAK GEOTECHNICAL, TABLE I PERCOLATION TEST RESULTS HOLE NO. HOLE DEPTH (INCHES) LENGTH OF INTERVAL (MIN) WATER DEPTH AT START OF INTERVAL (INCHES) WATER DEPTH AT END OF INTERVAL (INCHES) DROP IN WATER LEVEL (INCHES) AVERAGE PERCOLATION RATE (MIN.IINCH) P-1 46 30 8 7 1 60 7 6'/2 /2 61/2 6 '/2 6 5'/2 /2 P-2 48 30 8 7 1 60 7 6'/2 '/2 6'h 6 /2 6 51/2 Y, P-3 43 30 6% 5'/4 1'/4 5'/4 43/4 '/2 43/4 4'/4 '/2 NOTE: Percolation tests were performed in nominal 12 inch diameter by 12 inch deep hand dug holes in bottom of shallow backhoe pits dug and pre-soaked on May 3, 1998 by client. Percolation tsting condicted on May 4, 1998 by H -P Geotech. 000019 06/11/1998 16:43 000020 97096335 4 June 1998 To whom it may concern: Town of Carbondale 511 Colorado Avenue Carbondale, CO 81623 PAGE 01 (970) 963-2733 FAX (970) 963-9140 The Mobley residence at 0114 Hill Creek Road, Carbondale, CO 81623 is tapped onto the Town of Carbondale's wale: system. If you need addidoml information, please fed ftee to can me at. (970) 963-2733. Sincerely, JUN t t 1998 ENVIRONtviEN;R! HEALTH I{ste Marra N ; OT Assistant Finance Director ASPEN/PITKIN COMMUNITY DEVELOPMENT DEPARTMENT 130 South Galena Street Aspen, Colorado 81611 Phone (970) 920-5090 FAX (970) 920-5439 MEMORANDUM TO: County Attorney County Engineer Zoning Crystal River Caucus Colorado State Forest Service Env. Health, County Wildlife Biologist Division of Wildlife Carbondale & Rural Fire Protection District FROM: Tamara Pregl, Community Development Department RE: Mobley Minor 1041 Hazard Review Parcel ID 42643-341-02-042 DATE: April 30, 1998 000021 Attached for your review and comments is an application submitted by Terry & Jean Mobley. The Hearing Officer will review this application. Please return your comments to me no later than May 29, 1998. Thank you. =0 (t 7C!uf'X HEPWORTH-PAWLAK GEOTECHNICAL, INC. October 3, 1997 5020 Road 154 Glenwood Springs, CO 81601 Fax 970 945-8454 Phone 970 945-7988 Jean and Terry Mobely 114 North Bill Creek Road Carbondale, Colorado 81623 Job No. 197 575 Subject: Percolation Testing, Proposed Leach Field, Proposed New Modular Home, 114 North Bill Creek Road, Pitkin County, Colorado Dear Mr. & Mrs. Mobely: As requested, a representative of Hepworth-Pawlak Geotechnical, Inc. performed percolation testing at the subject site. The results of our work are presented in this report. The work was done in accordance with our agreement for geotechnical engineering services to you dated September 23, 1997. A profile pit and three shallow backhoe pits had been excavated in an area about 30 to 40 feet northwest of the existing residence as shown on Fig. 1. The pits had been excavated and the shallow pits had reportedly been pre-soaked by the client one day prior to our site visit. The subsoils observed in the profile pit consisted of about 1/2 foot of topsoil ove depth explored of 8 feet. No free water was encountered in the profile pit and the subs- o`er were moist. Percolation tests were performed in the silty sandy gravels on September 26, 1997 by a representative of Hepworth-Pawlak Geotechnical, Inc. The testing was conducted in the bottom of the shallow backhoe pits that were about 3 feet deep. The percolation test results are summarized on Table I. The percolation test results indicate an infiltration rate between 36 and 60 minutes per inch with an average at about 47 minutes per inch. The percolation rates were based on the last 3 readings of the test. Based on the subsurface conditions encountered and percolation test results, the tested site appears suitable for a conventional infiltration septic disposal system. If you have any questions, please call our office. Sincerely, HEPWORTH - PAWLAK � fiQiBWeC &L, INC. David A. Young, P.E. ��'., 3� 21 a Rev. By: DEH i��z''/Owt� DAY/kw attachment 000022 HEPWORTH-PAWLAK GEOTECHNICAL, INC. TABLE I PERCOLATION TEST RESULTS JOB NO. 197 575 HOLE NO. HOLE DEPTH (INCHES) LENGTH OF INTERVAL (MIN) WATER DEPTH AT START OF INTERVAL (INCHES) WATER DEPTH AT END OF INTERVAL (INCHES) DROP IN WATER LEVEL (INCHES) AVERAGE PERCOLATION RATE (MIN./INCH) P-1 48 15 1072 9'h 1 45 9'/z 8% 3/< 83/4 87a 72 8'/a 7 3/4 y2 7% 7'/2 '/4 7'h 7'% '/4 P-2 46 15 refilled 8 71/. % 36 7'A 6 72 3/a 6 72 6 /2 8% 874 8'/4 7% '/2 73/4 7 72 'A P-3 48 15 9 8'/2 '/2 60 8 72 8 /2 8 7'/2 /2 91/4 9 /4 9 83/ 74 83/4 8'/2 74 NOTE: Tests conducted in 12 inch diameter by 12 inch deep hand dug holes in bottom of backhoe pits excavated and soaked by client on 9-26-97. Percolation testing performed on 9-27-97 by H -P Geotech. 000023 P 2 0 ■ PROFILE PIT P 3 rrcvry cu Q SEPT C P 1 DISPOS L Q SITE .J EXISTING GARAGE EXISTING FENCE APPROXIMATE SCALE 1' = 20' EXISTING RESIDENCE ( TO BE REMOVED ) NORTH BILL CREEK ROAD 197 575 I GEOTECHNICAL, ZINC. I LOCATION OF PERCOLATION TEST HOLES I Fig. 1 nnnn,)A MEMORANDUM To: Tamara Pregl, Community Development Department From: Thomas S. Dunlop, Director Environmental Health Department Date: June 3, 1998 Re: Mobley Minor 1041 Hazard Review Parcel ID # 2643-341-02-042 The Aspen/ Pitkin Environmental Health Department has reviewed the details of the Mobley Minor 1041 Hazard Review application under the authority of the Pitkin County Land Use Code and has the following comments. ADEQUATE PROVISIONS FOR WATER NEEDS: Sections 2-17 and 3-1104: "It is the policy of the County to insure the availability of a water supply of adequate quality, quantity, pressure and dependability for fire protection and support of a proposed land use prior to approval of the use. The County shall require land uses to hook up to existing public systems if service is available." The applicant has agreed to serve the project with potable water provided by the Carbondale City Water System, but has not yet provided a "...letter of intent to service the proposal...'.' as defined in the Pitkin County Code. A condition of approval for this application is the receipt of written confirmation from the Carbondale City Water Department stating they can serve the Mobley residence. Without meeting this requirement a septic permit and building permit can not be issued. SEWAGE TREATMENT AND COLLECTION: Sections 2-18 and 3-1105: "it is the policy of the County to ensure that adequate sewage treatment facilities are available to serve existing and new developments. Public and private sewage disposal systems and connections to such systems shall comply with the sewage disposal guidelines of Pitkin County's Individual Sewage Disposal System Regulation." Lots in the area are served by individual septic systems. All such systems installed within Pitkin County require septic permits issued by the Environmental Health Department, and must comply with the County's septic regulations. To receive a septic permit, the applicant will need to submit a septic permit application through a Registered Professional Engineer who will design the domestic wastewater system. Included in the packet must be percolation test results and profile hole information, site plan with pertinent physical features, floor plan for the dwelling and Pmted Re kd Pap r 000025 ON caretaker unit (if applicable) and a copy of the County's 1041 approval. Once the completed application is received, this Department will analyze and review the proposed septic design. The applicant will need to adhere to minimum horizontal setback requirements for placement of septic system components. The leach field will need to be located a minimum of 100 feet from any and all wells. A condition of approval for this application is the septic system designed by Sopris Engineering shall be installed as designed, or with agreed to modifications of the original design. Issuance of the septic permit by the Environmental Health Department must occur prior to a building permit being issued. WATER OUALITY IMPACTS: Sections 2-14 and 3-705 and 3-710: "It is the policy of the County to preserve and protect its present water resources. To this end it is the policy of the County that no land use be initiated which would adversely affect the quantity, quality, or accessibility of the County's water resources; or which would occur at the expense. of established water -dependent agricultural activities; or which would result in increased salinizaflon of water resources, loss of minimum stream flows, further destruction of wildlife habitat, or major expenditures to reacquire or redistribute major water resources. It is also the policy of. the County to maintain a natural vegetative buffer along its surface waters such that the surface and groundwaters of the area are not encroached upon by land uses or other human activities which could cause deterioration of water quality or impair the natural treatment processes provided by meadows and wetlands." The Environmental Health Department will be addressing water quality impacts on down stream water quality. This application is not expected to impact .down stream water quality if the Ird imum horizontal distances between components of the septic system and physical features are in accordance with the Pitkin County Sewage Regulations. The Environmental Health Department is charged with preserving and protecting the quality of Pitkin County's water resources. Since a large percentage of the population is dependent upon water from wells, elimination of groundwater pollution, and protection of aquifers and their drainage areas are of utmost importance. Roofs and asphalt areas can be nonpoint sources of water discharge which can contaminate water supplies. This Department recommends that nonpoint sources of discharge be retained on the property of origin which can be accomplished through landscaping, drainage patterns, detention ponds, and dry wells for water runoff from buildings. A condition of approval for this application is: None AIR QUALITY: Sections 2-13 and 3-602: "Only that development is permitted which will not contribute significantly to degradation of air quality in Pitkin County. Developments may not constitute an indirect or direct air pollution source under Federal, State or County regulations." This project is not expected to contribute significantly to degradation of air quality in Pitkin County. rnn�"a "� a"drdea r"r". 000026 A condition of approval for this application is: None FUGITIVE DUST Activities such as road building and landscaping require a Fugitive Dust Plan. This plan would need to include, but is not limited to; fencing, watering of haul roads and disturbed areas, daily cleaning of adjacent paved roads to remove mud that has been carried out, speed limits, or other measures necessary to prevent windblown dust from crossing the property line or causing a nuisance. A condition of approval for this application is: None, since this is a request for a single family dwelling with a small proposed driveway. FIREPLACE The applicant must file a fireplace/woodstove permit with the Environmental Health Department before the building permit will be issued. The less densely populated parts of the county, like this site, may have two devices per building: a maximum of one wood burning fireplace and a second device which can be either a gas log fireplace or a certified woodstove. In addition, unlimited numbers of decorative gas appliances are allowed. Coal may not be burned in any device. No wood burning device may be installed in barns or agricultural buildings. A condition of approval for this application is: None, since the applicant has submitted the required fireplace registration permit. ASBESTOS Private Residential: Prior to demolition the applicant should have the building tested for asbestos, and if any is present, should contact this Department regarding proper removal. Condition of approval of this application is: None, since no demolition is proposed for the existing mobile home. CONFORMANCE WITH OTHER ENVIRONMENTAL HEALTH LAWS: Section 2-7: "It is the policy of the County to ensure that no use or development of land is permitted which is in violation of the laws of the County, the State of Colorado, or the United States of America." This Department is not aware of any issues of concern regarding other environmental health laws. lur.mobley.doc PenxW u" R¢ kd P.p 000027 RW—lb-1998 15:35 DATE: April 16, 1998 FROM RSPEWPITKIN COM DEV C3 TO PTTKIN COUNTY PRF. -APPLICATION CONFERENCE SUMMARY PROJECT: Mobley Minor 1041 Hazard Review LOCATION: The property is located in the Seven Oaks Tracts in the Crystal River Valley. address of the property is 114 N. Bill Creek Road. APPLICANT: lean Mobley PLANNER: Tamara Pregl PHONE/FAX: 963-3581 PHONE: 920-5103 1. Type of Application: Minor 1041 Hazard Review and General Submission 2. Description of Project/Development: The applicant is requesting approval of a Minor 1041 Hazard Review to construct a single family residence. The property is mapped for deer and elk winter range and low wildfire. In the area of proposed development, the property contain slopes of greater than 15%. 3. Areas in which the Applicant has been requested to respond, types of reports requested: Land Use Code Sections to be address in letter of request (application): 3-80.*C) Geologic Hazard Areas 3-80.70 Wildfire .Areas 3-80.80 Wildlife Habitat Areas 3-110 Improvements and Services 4-50 Procedure 5-70 Submission Contents 4. Staff will refer the application to the following agencies: a. County Attorney b. County Engineer c. Zoning d. Crystal River Caucus e. Colorado State Forest Service f Environmental Health Department g. County Wildlife Biologist h. Division of Wildlife i. Carbondale & Rural Fire Protection District 5. Review by: Hearing Officer 6. Public hearing? Yes. The Applicant must post a sign on the property for the public hearing pursuant to Section 4-90 of the Code. 000023 RPR -16-1998 15:35 FROM RSPEN/PITKIN COM DEU Pre -Application: Mobley Minor 1041 Hazard Review April 16, 1998 Page 2 Adjacent Property Owners: The Applicant is required to submit a list of adjacent property owners (one copy) and an addressed envelope for each owner. 8. Number of copies of the application and maps to be submitted: 10 9. What fee was the applicant requested to submit: $780 ($460 for Planning; $160 Environmental Health Department, $160 County Engineer). 10. For a complete application, please include the following in each packet: a. Letter of request (application) addressing Code Sections listed above; b. Consent from owner(s) to process application and authorizing the representative (if applicable); e. Parcel description, including legal description and vicinity map; d. Proof of ownership (from a title company or attorney licensed in the State of Colorado); e. A site plan delineating a building envelope which should include the proposed dwelling unit, septic system, proposed landscaping, etc; f. Copy of this pro -app form; 11. Application fee and the agreement to pay form (2 copies) shall be submitted with complete application. NOTE: This preapplication conference summary is advisory in nature and not binding on the County The information provided in this summary, is based on current zoning standards and staffs interpretations based upon representations of the applicant. Additional information may be required upon complete review of the application. 000029 ADJOINING 20D9-27 T01a001 ItTW 1 t TRACT D IT11A1�l7TRACT IJ12.K 9 o >< 6 as i,r. .10, � I✓� rr K. 4 >bat� bL t IOU A S 1 ®{ 11 w T3(5 ACT • rnAR c IR Slr® ran a oO °TRAR ]0 fa yT wb , as i•T' r calm & f r �'�TRAer L».:• TUC 0 • �y ,la u< 00 � TRACT 6 I A.D. oo 22 TK1; r rRAiCr i' (� // •`• at 26 . a• ,ear 1 O xs ti _ • aTA ®6TI 25 WK AD . TGUI CT , _ T • � ®l O / ba0 �T'aO �TRACT 6 a S ® a (005i E Is. K ., waaC. Y TRACT 24 ", 1 4 aiaw .yl. ^ 1R� p 'C pf TRACT y� \ V I l.il'' 1 R TRACT as la _ i iex» ej J N zs e R�4 .aaa ACT An.11 ooz 23� a iso x TRACT 2 enK . TRACT I .• " p TRACT 19' w w Nei i •�• MM P a \ r _ aOln ro iy a K wrn/7nr® A`ag Cc U1 "rP p. iilj ,SIgT 9' @�JROlaaT " O C 006 a�Na , Ip•� y a 'e— TRACT uaNa AC T'lid.a0 .•r� � 'I>n aC F TRACT 10 T • {' iofzO TRACT IIT 6 � w 000030 A �' 7 ACT I a A 14 we;r • fa • a ALTA OWNER'S POLICY — 10/21/87 POLICY OF TITLE INSURANCE ISSUED BY STEWART TITLE GUARANTY COMPANY SUBJECT TO THE EXCLUSIONS FROM COVERAGE, THE EXCEPTIONS FROM COVERAGE CONTAINED IN SCHEDULE B AND THE CONDITIONS AND STIPULATIONS, STEWART TITLE GUARANTY COMPANY, a Texas corporation, herein called the Company, insures, as of Date of Policy shown in Schedule A, against loss or damage, not exceeding the Amount of Insurance stated in Schedule A, sustained or incurred by the insured by reason of� 1. Title to the estate or interest described In Schedule A being vested other than as stated therein, 2. Any defect in or lien or encumbrance on the title, 3. Unmarketability of the title, 4. Lack of a right of access to and from the land. The Company will also pay the costs, attorneys' fees and exper4a InrSUtred In defense of the title, as insured, but only to the extent provided In the Conditions and Stipulations. IN WITNESS WHEREOF, Stewart Title Guaranty Company has caused this policy to be signed and sealed by Its duly authorized officers as of the Date of Policy shown In Schedule A. Fes:... CrK.irman o :Ol41d / A ts/ Company STEWART TITLI ovARAnrr COMPANY city, state EXCLUSIONS FROM COVERAGE The following matters are expressly excluded from the coverage of this policy and the Company will riot pay loss or damage, costs, attorneys' fees or expenses which arise by reason ot: 1. (a) Any law, ordinance or governmental regulation (Including but not limited to building and zoning laws, ordinances, or regulations) restricting, regulating, prohibiting or relating to (1) the occupancy, use, or enjoyment 1N the land; (II) the character, dimensions or location of any Improvement now or hereafter erected on the land; (III) a separation in ownership or a change In the dimensions or area of the land or any parcel of which the land Is or was a part; or (Iv) environmental protection, or the effect of any violation of these laws, ordinances or governmental regulations, except to the extent that a notice of the enforcement thereof or a notice of a defect, lien or encumbrance resulting from a violation or alleged violation affecting the land has been recorded In the public records at Date of Policy. (b) Any governmental police power not excluded by (a) above, except to the extent that a notice of the exercise therol or a notice of a defect, lien or encumbrance resulting from a violation or alleged violation affecting the land has been recorded in the public records at Date of Policy. 2. Rights of eminent domain unless notice of the exercise thereof has been recorded In the public records at Date of Policy, but not excluding from coverage any taking which has occurred prior to Date of Policy which would be binding on the rights of a purchaser for value without knowledge. 3. Defects, liens, encumbrances, adverse claims or other matters: (a) created, suffered, assumed or agreed to by the insured claimant; (b) not known to the Company, not recorded in the public records at Date of Polley, but known to the insured claimant and not disclosed in writing to the Company by the insured claimant prior to the date the insured claimant became an insured under this policy; (c) resulting In no loss or damage to the insured claimant; (d) attaching or created subsequent to Date of Policy; or (e) resulting In loss or damage which would not have been sustained if the insured claimant had paid value for the estate or interest insured by this policy. 1 of Opt )R... 10/21/8]) 000031 S C H E D U L E ORDER NO.: 00017151 0 A POLICY NO.: 0-9941456551 DATE OF POLICY: December 19, 1.989 at 2:51 P.M. AMOUNT OF INSURANCE: $ 50,000.00 1. NAME OF INSURED: TERRY LEE MOBLEY AND JEAN MARIE KLOSSNER-MOBLEY 2. THE ESTATE OR INTEREST IN THE LAND WHICH IS COVERED BY THIS POLICY 1S: Fee Simple 3. TITLE. TO THE ESTATE OR INTEREST IN THE LAND IS VESTED IN: TERRY LEE MOBLEY AND JEAN MARIE KLOSSNER-MOBLEY 4. THE LAND REFERRED TO IN THIS POLICY IS DESCRIBED AS FOLLOWS: SEE LEGAL DESCRIPTION ATTACHED HERETO & MADE A PART HEREOF. AUTHORIZED SIGNATURE oct000m'"o) 000032 Stewart Title of Aspen, Inc. 602 E. Hyman Aspen, CO 81611 303-925-3577 STEWART TITLE GUARANTY COMPANY S C H E D U L E ft 0 POLICY NO.: 0-9941456551 THIS POLICY DOES NOT INSURE AGAINST LOSS OR DAMAGE (AND THE COMPANY WILL NOT PAY COSTS, ATTORNEYS' FEES OR EXPENSES) WHICH ARISE BY REASON OF: 1. RIGHTS OR CLAIMS OF PARTIES IN POSSESSION NOT SHOWN BY THE PUBLIC RECORDS. 2. EASEMENTS, OR CLAIMS OF EASEMENTS, NOT SHOWN BY THE PUBLIC RECORDS. 3. DISCREPANCIES, CONFLICTS IN BOUNDARY LINES, SHORTAGE 1N AREA, ENCROACHMENTS, AND ANY FACTS WHICH A CORRECT SURVEY AND INSPECTION OF THE PREMISES WOULD DISCLOSE AND WHICH ARE NOT SHOWN BY THE PUBLIC RECORDS. 4. ANY LIEN, OR RIGHT TO A LIEN, FOR SERVICES, LABOR OR MATERIAL HERETOFORE OR HEREAFTER FURNISHED, IMPOSED BY LAW AND NOT SHOWN BY THE PUBLIC RECORDS. 5. UNPATENTED MINING CLAIMS; WATER RIGHTS, CLAIMS OR TITLE TO WATER. 6. ANY AND ALL UNPAID TAXES AND ASSESSMENTS AND ANY UNREDEEML;D TAX SALES. 7. THE EFFECT OF INCLUSIONS IN ANY GENERAL OR SPECIFIC WATER CONSERVANCY, FIRE PROTECTION, SOIL CONSERVATION OR OTHER DISTRICT OR INCLUSIONS IN ANY WATER SERVICE OR STREET IMPROVEMENT AREA. 8. Right of the proprietor of a vein or lode to extract and remove his ore therefrom, should the same be found to penetrate or intersect the premises hereby granted, as reserved in United States Patent recorded January 6, 1903 in Book 55 at Page 117. 9. Right of way for ditches or canals constructed by the authority of the United States, as reserved in United States Patent recorded September 10, 1952 in Book 180 at Page 49 as ReCePtiOn No. 99558. 10. All uranium, thorium or any other material which is or may be determined to be peculiarly essential to the production of fissonable materials as reserved in United States Patent recorded September 10, 1952 in Book 180 at Page 49 as Reception No. 99558- 11. Easement and right of way for an easement for the construction, operation, maintenance and reconstruction of electric Continued on next page STEWART TrrEE OUAKANTT COMPANY 9C(OMM 19-99) 000033 AM i 12 13. C ATTACHED TO AND MADE A PART OF STEWART TITLE GUARANTY COMPANY CONTINUATION OF SCHEDULE B ft POLICY NO.: 0-9941456551 transmission line as granted to Public Service Company of Colorado by R.O. Sewell, Nellie Sewell and The Federal Land Bank of Wichita, in the instrument recorded March 23, 1960 in Book 190 at Page 190, affecting the following described property: over and across portion 27 and Township 8South, Range88 Westof the S6th 1on 21, � PrincipalMeridiani4 Easement and right of way for the construction, reconstruction, operation, and maintenance of an underground water transmission pipeline for transmission of water as granted to Town of Carbondale by R.O. Sewell and Nellie Sewell in the .instrument recorded March 6, 1964 in Book 206 at Page 162 as Reception No. 117244, affecting the following described property: An easement twenty (20) feet in width, said easement lying Ten (10) feet on each side of the following described centerline as same extends across Lot 4, Section 3, Township 9 S., R. 86 W. of the 6th P.M., and NE 1/4 SW 1/4, SE 1/4 NW 1/4, and the W 1/2 NE 1/4 of. Section 34, Township 8 S., R. 88 W. of the 6th P.M. Easement and right of way for the right to construct, operate, maintain, replace, enlarge, reconstruct, improve, repair and remove such communication line facilities and appurtenances as granted to The Mountain States Telephone and Telegraph Company by R.O. Sewell in the instrument recorded July 23, 1969 in Book 242 at Page 324 as Reception No. 136264, affecting the foll.owing described property: A strip of land five (5) feet in width on each side of a centerline in Section 34, Township 8 South, Range 88 West of the 6th Principal Meridian. 14. Restrictions, as referred to in instument recorded October 16, 1970 in Book 251 at Page 339. 15. Easement or right of way 10 feet in width over and across the easterly 10 feet and westerly 10 feet of subject property as disclosed by document recorded October 16, 1970 in Book 251 at Page 339. 16. Right of way for the Bain -Thomas Ditch insofar as it may affect subject property. 17. A Deed of Trust dated December 19, 1989, executed by Terry Lee Mobley and Jean Marie Klossner-Mobley, to the Public Trustee of Pitkin County, to secure an indebtedness of $45,000.00, in favor of Robert Von Dette and Virginia M. Von Dette, recorded December 19, 1989 in Book 610 at Page 128 as Reception No. 318324. i4TEWART TITLE GUARANTY C(IMYANY we :eooM 10-69: 000034 SCHEDULE A PROPERTY DESCRIPTION ORDER NO: 00017151 A tract of land situated in the SW 1/4 NE 1/4 and SE 1/4 NW 1/4 of Section 34, Township 8 South, Range 88 West of the 6th Principal Meridian, described as follows: Beginning at a point whence an iron post with a brass cap properly marked for the center of said Section 34 bears S. 01 degrees 49 minutes 59 seconds E. 871.02 feet; thence N. 20 degrees 42 minutes E. 140.05 feet; thence N. 14 degrees 44 minutes 30 seconds E. 15.68 feet; thence S. 89 degrees 50 minutes E. 306.38 feet; thence S. 33 degrees 47 minutes W. 175.07 feet; thence N. 89 degrees 57 minutes W. 262.51 feet to the point of beginning. County of Pitkin, State of Colorado STEWART TITLE GUARANTY COMPANY "=6 ■ ASPEN/r YIN ENVIRONMENTAL HEALTH' PARTMENT APPLICATIuO FOR INDIVIDUAL SEWAGE DISr JSAL SYSTEM 130 S. Galena St., Aspen Colorado 81611 Phone 970-920-5070/Fax 970-920-5039 Name of OWNER/ L 1 U b55V(�- Y t C e Owner's Mailing Address 7,16 Business Phone Home Phone: vl 70 903 3 V f Primary Contact Person (all communication regarding this permit will go through this person) Name ��elo I fb r✓ Company p���77 // -- /nl / Contact Mailing Address D Jlo Civ P C� �tiJ� Phone : Parcel ID # (available from assessor's otttce at 920-5160 or at www.aspen.com/assessorn Street address of property I I -} N a li)� (,K Legal Description: Lot —LO-- ,Block Filing Size of lot: acres. Type of proposed structure: � ZAMZr -L „3- 3 14 -L-0 > , -Q q- � ,Subdivision Size of bldg. envelope: Total square feet of house # of bedrooms in house # of offices, lofts & similar sized rooms in house Caretaker Unit: Attached ( ) Detached ( )oms in caretaker unit # of office: Total area(sq. ft.) of caretaker unit imilar size rooms of caretaker unit Permit is for: New Home (✓) Repair due to failure ( ) Remodel/Addition ( ) Emergency use ( ) Water: Private well ( ) Spring ( ) Stream ( ) Community/Public Water System (� �,(Q)If community system: Name of system &%do/C (1 l/ The fee for a ISDS application is $330 for a permit that takes 6 hours or less for the department to approve. If approval takes longer than 6 hours, a rate of $55 per hour will be charged. The maximum fee is $1000. The basic fee of $330 is due at the time of application. The remainder, if any will be due in two stages: first, at the time of issuance of the ISDS permit; second, before final approval of the ISDS permit. Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information is true and accurate and that 1 have provided true and accurate information on locations of all existing and proposed wells, contour intervals, buildings, property lines, ditches, slopes, waterlines, springs, suction or irrigation lines, drinking water cisterns, drain tiles, irrigation ditches, lakes, water courses, streams, floodplains, dry gulches, and existing septic systems. I hereby certify that any such features not shown on attached site map are not present. Issuance of the permit does not imply the approval of any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all approvals and permits have been obtained. The Aspen/Pitkin Environmental Health Department, Pitkin County and employees of these agencies will be held harmless should the individual sewage disposal system fail or malfunction. The permit to construct is issued on information submitted by the applicant or his/her representatives. The owner assumes full responsibility in case of failure of the system. 000034gnature of applicant Date 1t -2,1'�0( C, march 26, 1998 Jean and Terry Mobley P.O. Box 856 Carbondale, CO 81623 RE: ISDS Design, New Home, 114 North Bill Creek Road, Pitkin County, Colorado SE Project No. 98013.01 Dear Mr. and Mrs. Mobley: As you requested, we have reviewed the report by Hepworth Pawlak Geotechnical, Inc., dated October 3, 1997 under Job No. 197 575, in which they determined the average percolation was 47 minutes per inch. We also reviewed an improvement survey prepared by the Sexton Survey Co. dated October 10, 1997 under Job No. 97013, which shows the site conditions. It is our understanding the existing trailer house is to be removed and replaced with a new home with four bedrooms. We have designed an individual sewage disposal system (ISDS) based upon the above-mentioned information for a four bedroom house. The site sloped from the east to west at a moderate slope of 10% to 15%. An existing sewage leach field is located approximately 10 feet north of an existing garage. This design was based upon a new leach field and the old field to be abandoned. The location of the proposed leach field is shown on the attached Exhibit A. The sewage load for a four bedroom home is 800 gallons per day (gpd). A peaking factor of 1.75 for design loading equals 1400 gpd. We recommend a standard seepage bed for the ISDS to be installed as shown on Exhibit A. Design Criteria: No. of bedrooms: 4 Loading - Q - 800 gpd Percolation Rate - T - 47 minutes per inch Area - (1.75xQx�T)/5 Total Area - 1920 s.f. For bed specifications, see attached Exhibit B. Septic Tank: 30 hour retention required 1.25x800xl.75=1750 gallon We recommend a 1750 gallon, two-compartment, pre -cast concrete septic tank and a distribution box to be installed to distribute effluent on both ends of the field. The dispersal gravel to be covered with a Miraft 140n geotextile fabric or approved equal. 000037 502 main street • suite A3 • Carbondale, CO 81623 • (970) 704-0311 • fax (970) 704-0313 SopRis ENGINEERING 9 LLC civil consultants Jean and Terry Moble ISDS Design Recommendations March 26, 1998 Page 2 We recommend the surface of the field be seeded using a native seed mix available at seed stores. No landscaping or automatic sprinkler system is allowed over the field. Livestock should not be confined in the field area. Our design and recommendations are based upon data supplied to us by others. If subsurface or site conditions are found to be different from those described in this report, we should be notified to evaluate the effect it may have on the proposed ISDS. If the County Environmental Health Department requests changes or modifications to this design, we should be contacted to evaluate the effect on the ISDS. All construction shall be in accordance with the ISDS Regulations. If you have any questions, or need any additional information, please call. Sincerely, SOPRIS ENCjA{jjhfi4 yG, LLC 3 i� nnn03� PEG. POUND #5 REBAR 000039 SET REBAR & CAP P LS 31944 6y SAI-Ve-1 Cd. 262.51' - - BASIS OF BEARING ..77 RACY 6 951 ACRES Z:7 T� 9'RaI of I0/4., ll;.e , / ) ra ) /'�Zo m GIM tcX tl �e �R Vr1 C Qr G�q�QraJtd Py4�' � — a Ff 6 / uat '(a S t /a-le4 a --Jr o w � PPr o.a l k jp -50 pp 06sr. y4f�.. /ire S_i (��%l 5� - ! q- tout - v4y raSS 5c- � P A4 )rat;) / �Zo N G e) i k -� T=_ _ —= t40 0SJe.uc4" / r/ O)SPersof Graue. r D) a �f S 6 u trete Cuk L 414 rn Fd)6;f �' 3&0� l r �al-lz ASPEN/PITKI, . _NVIRONMENTAL HEALTH DEPARTMEN ISDS DESIGN REQUIREMENTS DEPARTMENT USE ONLY Name Mobley Terry & Jean House Size 2582 Number of Bedrooms, Lofts, Offices, Number of Bedrooms, Lofts, Offices, Average Daily Waste Flow State Review Required? no Perc Rate 47 (T) Permit # Parcel I D # 2463-341-02-042 (75 gpd, 100 gpd, or 130 gpd) 100 Similar Rooms, Main House 5 Similar Rooms, Caretaker unit 750 # bedrooms X 2 people/br X 75 (make sure to use state # of bedrooms) Design Flo w (Q) = # bedrooms X 2 people/bedroom X gpd X 1.75 Q= 1750 > 6t Absorption Area (A= Q/5 X SORT) 161D A = 2399.479 sq. ft. of absorption area required 155 infiltrator units without reduction or 799.8264 lineal feet of S wide trenches The maximum 30% reduction is allowed for use of deep gravel or gravelless chambered system. ONLY if lot and soil conditions are optimal, which they are not on this lot, due to the poor soil percolation rate. Type of system: []Absorption trenches []Absorption bed U Gravelless chambers []Dry well []Seepage Pit []Pumping Chamber Minimum tank capacity 2187.5 gallons SETBACK FROM WELL # of feet = 160 Remember: 8 feet of additional distance for each 100 gallons/day of design flow over 1,000 gal/da should be added unless an RPE can verify that it is not necessary to prevent contamination. V APPROVED FOR ISSUE BY: DATE: SYSTEM INSTALLED BY: DATE OF FINAL INSPECTION REQUEST: FINAL INSPECTION BY: DATE: Printed on Recycled Paper 000041 0130 000042 550 ASPEN/PITKuv ENVIRONMENTAL HEALTH DEPARTMEii I ISDS DESIGN REQUIREMENTS DEPARTMENT USE ONLY Name Mobley, Terry & Jean Permit # Parcel ID # 2463-341-02-042 House Size 2582 (75 gpd, 100 gpd, or 130 gpd) 100 Number of Bedrooms, Lofts, Offices, Similar Rooms, Main House 4 Number of Bedrooms, Lofts, Offices, Similar Rooms, Caretaker unit Average Daily Waste Flow 600 # bedrooms X 2 people/br X 75 State Review Required? no (make sure to use state # of bedrooms) Perc Rate 47 (T) Design Flo w (Q) = # bedrooms X 2 people/bedroom X gpd X 1.75 Q= 1400 Absorption Area (A= Q/5 X SORT) A = 1919.583 sq. ft. of absorption area required 30 x aO 124 infiltrator units without reduction 30'!L or 639.8611 lineal feet of 3' wide trenches The maximum 30% reduction is allowed for use of deep gravel or gravelless chambered system. ONLY if lot and soil conditions are optimal, which they are not on this lot, due to the poor soil percolation rate. Type of system: []Absorption trenches (]Absorption bed 0 Gravelless chambers []Dry well []Seepage Pit []Pumping Chamber Minimum tank capacity 1750 gallons SETBACK FROM WELL # of feet = 132 1 Lk-'kI '�O 0Q) Remember: 8 feet of additional distance for each 100 gallons/day of design flow over 1,000 gal/da should be added unless an RPE can verify that it is not necessary to prevent contamination. APPROVED FOR ISSUE BY: SYSTEM INSTALLED BY: DATE OF FINAL INSPECTION REQUEST: FINAL INSPECTION BY: Printed on Recycled Paper 000043 DATE: DATE: �.,., � � 1��� I'• ' PITKIN COUI`ITY TAX NOTICE For 1997 , due in 1998 `�� ��XHdA99.YNal:]ih1d61y J:U19�aA'1 A TRACT OF LAND SITUATED IN SW4NE4 NO SE4NW4 OF SEC. 34-8-88, FULLY DESCRIBED BY METES AND BOUNDS, SEE DEED IN BOOK 473 PAGE 871. PITKIN COUNTY RECORDS. SEE BOOK 610, PAGE 125 PITKIN COUNTY RECORDS. SUB:LOWER SEWELL TRACTS LOT:6 BK:0522 PG:0928 Without state legislative fundingour school general fund mill levy would have boon 48.4 . A mill levy is the lax rate per $1.000 of assessed valuation. PROPERTY ACTUAL VALUE I LAND VALUATION 1BURLDINGVALLIATION PITKIN COUNTY TREASURER 506 E. MAIN ST., SUITE 201 ASPEN, COLORADO 81611-1993 PHONE # (970) 920-5170 FAX # (970) 920-5174 PITKIN COUNTY 3.771 0.245 $33.99 OPEN SPACE 8 TRAILS 2.519 $24.28 COUNTY HOUSING DEBT 0.450 $4.34 CARBONDALE FIRE PROTECTIO 5.035 $48.54 ROARING FORK SCHOOL DIST 43.424 $418.61 COLORADO MTN COLLEGE 3.997 0.053 $38.02 COLORADO RIVER WATER CONS 0.307 $2.96 PITKIN COUNTY LIBRARY 1.406 0.087 $12.72 IS YOUR ADDRESS CORRECT? Please check the box on the COUPON tot Change of address. MOBLEY TERRY LEE MOBLEY JEAN MARIE KLOSSNER PO BOX 856 CARBONDALE, CO 81623-0856 PLEASE SEE REVERSE SIDE OF THIS FORM FOR ADDITIONAL INFORMATION. 000045 CHG/CITY LIENISPECIAL 0 TAX NOTICE $0.00 $291.73 $291.73 rO IT DUE APRIL 30 ' Make checks payable to:PITKIN COUNTY TREASURER Post-dated checks are not accepted. If your property tax is to be paid by a mortgage company, please forward this notice to them. If you have sold this property, please forward this statement to the new owner or return it to this office marked "property sold"(and include the Name and Address of the new owner if known). RETAIN TOP PORTION FOR YOUR RECORDS. la" -6�- �o h �� Wit- . - • 1 +- k.(�oe 6-paL div AQ 49 --- LO he lowe<c(4t1v�5. . -- -Ujo I/- 000048 000049 - - - - -- --- O 6'2 O r—i -- — C= 0 c c LT x WX 000052 aror 6oXCS n1' s y � d A/' /%he M � � 000053 ,3v * 1 6 36' f f 0 s y � d A/' /%he M � � 000053 ,3v * O 36' f s y � d A/' /%he M � � 000053 ,3v * AREA U • x h SCPFl4DC N P ANE r w T K 24" 18" 79 8, 735, LI j �E9�4 T. �LCIt! / t W4LK IC MAP U71L m SEW POLE ,o D 8AS1S . 0E.z-BEARING ON o e= 6pr Q�u`''yo •.. AREA U • x h SCPFl4DC N P ANE r w T K 24" 18" 79 8, 735, LI j �E9�4 T. �LCIt! / t W4LK IC MAP . /112' SEW 12AGTS / METAL S 39 SO. % 30 .38' R, C 6 95 CRES ZL// R O 00 TgOK SHED 144 S4 C� Ar x OOCORAL ../I'T 16c, UGH BRUSH X / THIS A EA .. Oo vy / J JO �= 877 e yb6�yi sow SE RE RMAR• &- ..FOUND EAP,. :.. P.LS Ju ECABLE:�78013.v __ •. Faz ;t "J. ti. .^�_ i'G .J..•J -ew: _ .��,•'�y,. .+•.'•`i . .?.S - 'a...:'• _x'.� .. z_ 'f' a-:a'Tea, .. _-..26251' "• 8AS1S . 0E.z-BEARING •.. •La•^f il�l�l�r}'..n.L/�"':Yl. Y�..af Sir... e. S' - v��J'�. A�'� C� Ar x OOCORAL ../I'T 16c, UGH BRUSH X / THIS A EA .. Oo vy / J JO �= 877 e yb6�yi sow SE RE RMAR• &- ..FOUND EAP,. :.. P.LS Ju ECABLE:�78013.v __ •. Faz ;t "J. ti. .^�_ i'G .J..•J -ew: _ .��,•'�y,. .+•.'•`i . .?.S - 'a...:'• _x'.� .. z_ 'f' a-:a'Tea, 000055 000056 O 555p111 ''1 Q r � � of X O Stv /�y Q� I , PEA �. e 000057 CAPREBAR do �- • P.LS. 31944 �y /. POLE so O 555p111 ''1 Q r � � of X O Stv /�y Q� I , PEA �. e 000057 GRAVELRIVE & PARKI C AREA 1. . FOUND #5 RESAR S�pr 1A .e,o4Kol 6y 9 ! 7 1 �— c — o_ k F ��CL' /QIIr 10 a 4,7Z if �. +JU+ / 2f3 s w l r 5c•ow 1= `t 0 21 ;L.�TfZALTS / 1 1 IJ �l ae METAL S 7 S X50' 30,6.3IS 77 t RA6 / OHO 951CRES/ 1^- CEDAR -12.00' Nt / o 4au• Yu O WOOD IN TACSHED 144 SOFT UVER THIS 3�e a" VALLOW a 262.51' BASIS OF BEARING — / 4c /-/47y Toz 41 (q, )tT1-x n" v ' �y o !' 14" I GRAVELRIVE & PARKI C AREA 1. . FOUND #5 RESAR S�pr 1A .e,o4Kol 6y 9 ! 7 1 �— c — o_ k F ��CL' /QIIr 10 a 4,7Z if �. +JU+ / 2f3 s w l r 5c•ow 1= `t 0 21 ;L.�TfZALTS / 1 1 IJ �l ae METAL S 7 S X50' 30,6.3IS 77 t RA6 / OHO 951CRES/ 1^- CEDAR -12.00' Nt / o 4au• Yu O WOOD IN TACSHED 144 SOFT UVER THIS 3�e a" VALLOW a 262.51' BASIS OF BEARING — / 4c /-/47y Toz 41 (q, )tT1-x n" 20 0 I I I U i V e I � i I I i GRAPHIC SCALE I I 20 .0 ( IN Frye ) I inch = 20 ft SET REBAR & CAP P.L.S. 31944 UTIL. e / POLE � -- / AFFric , Y z k F1ELU O l'A00 60 Y "o /� r NFr0y• 20, f'4nPANE / '^ WANT -LR kINE T " SMT. S &2ROV✓ t W4 K Q MAP 60 J�1�'� t1 1966 24' ( SEWTZAC Q� } 14" eS& / t v a � 14" O v I Ur 'wry 0 I 0 wOODE N 8004, OF'CH . 7.3 p / Y GRAVEL RIVE 4< .5 p1 & PARKI G AREA 12 m I 1 z� 8" vr.I uaw K.w PED. 262.51' FOUND #5 REBAR BASIS OF BEARING PROPERT DESCRIPTION A TRACT OF LAND SITUATED IN THE SW1/4NE1/4 AND SE1/4NW1/4 OF SECTION 34, TOWNSHIP 8 SOUTH, RANGE 88 WEST OF THE 6TH PRINCIPAL MERIDIAN, DESCRIBED AS FOLLOWS: BEGINNING AT A POINT WHENCE AN IRON POST WITH A BRASS CAP PROPERLY MARKED FOR THE CENTER OF SAID SECTION 34 BEARS St'49'59'E 871.02 FEET; THENCE N20'42'E 140.05 FEET; THENCE N14'44'30'E 15.68'; THENCE S89'50'E 306.38 FEET; THENCE S33'47'W 175.07 FEET; THENCE N89'57'W 262.51 FEET TO THE POINT OF BEGINNING TOGETHER WITH AN EASEMENT OF RIGHT—OF—WAY OVER AND ACROSS EXISTING ROADS FOR ACCESS PURPOSE FROM THE ABOVE DESCRIBED PROPERTY TO 0114 NO. BILL CREEK RD., COLORADO STATE HIGHWAY #133 SAID PROPERTY CONTAINS 0.951 ACRES AS DESCRIBED I I I I J A_yN�lyl �? �' i'��Ji " 30,6.38` xY R A C 6�p �p .951 CRES w60� ��'Q xr x CORAL 1'1,�, / + / SHED 12,00* 12" DAR 1 + / 14 S�F �c i ji WA R DUET ji l:4' ELEC OUTL LA / LIGfi' BRUSH p OjIER THIS EA NOTES: - SURVEY ORIENTATION BASED ON MONUMENTS FOUND AND SHOWN HEREON. - EASEMENTS SHOWN ARE FROM BOOK 522 PAGE 928 PITKIN,''OUNTY, CO. THIS SURVEY WAS DONE WITHOUT THE BENIFIT OF A TITLE COMMITMENT INDICATES DECIDIOUS TREE UNLESS OTHERWISE NOTED - ELEVATIONS ARE BASED ON AN ASSUMED ELEVATION OF 1040.4' ON TOP OF A REBAR & CAP ILLEGABLE AT THE SE CORNER OF TRACT 6 THE SEXTON SURVEY CO. 819 WEST 3RD STREET RIFLE, COLORADO 81650 (970) 625-3711 OR 945-4700 Fax (970) 625-3711 LIGH R OVEff Tyt S AS2EA j C`}�' ^ +/C / 0,0 FOUND REBAR & CAP P.L.S. ILLEGABLE BM ELEVATION 1040.4' SET REBAR & CAP .L. S. 31944 SURVEYOR'S CERTIFICATE 1, BRIAN A. STEINWINDER, BEING A REGISTERED LAND SURVEYOR IN THE STATE OF COLORADO, DO HEREBY CERTIFY THAT THIS IMPROVEMENT SURVEY WAS MADE UNDER MY SUPERVISION AND IS TRUE AND CORRECT TO THE BEST OF MY BELIEF AND KNOWLEDGE. I FURTHER CERTIFY THAT THE IMPROVEMENTS ON THIS DATE, SEPT. 14, 1997, EXCEPT UTILITY CONNECTIONS ARE ENTIRELY WITHIN THE BOUNDARIES OF THE PARCEL. EXCEPT AS SHOWN, THAT THERE ARE NO ENCROACHMENTS UPON THE DESCRIBED PREMISES BY IMPROVEMENTS ON ANY ADJOINING PREMISES EXCEPT AS INDICATED, AND THAT ,THERE IS NO APPARENT EVIDENCE OR SIGN OF ANY EASEMENT CROSSING OR BURDENING ANY PART OF SAID PARCEL, EXCEPT AS NOTED. `a���O�POpnRE��s,,o \�� Q iy ��� gyp••• PN STFi 'TF9 , BRIAN A. ST fF #NDER P.L. 44 DATE • f�,�ss,�NAI LAN�,aJ�\\` IMPR0 VEMENT SURVEY TRACT -6 SECTION -34 T8S, R88W—.6THP. M. PITKIN COUNTY, CO. • I job No. 9701.3 Drown by: BAS Dote: 10/10/97 Rev., Rev., 1 OF' 1 000053