Loading...
HomeMy WebLinkAboutpitkin.eh.246522200004 (1997)14S 128 C 126 V� Af I1� 1'A �I• �� 8 � 10 " '\ fl' � yD p• - UNDERGROUND14 PROPANE n 124 ENCLOSEDC TERRACE INSPECTION WELL (TYP) — ' _ ... - e� Is� r 7'-0" STONE WALL \ Z.�' WELL 1000 GAL. PRECAST CONCRETE SEPTIC TANK 118 �,: F°,r, , , � f 1 _ �'�..,-�,�:,i—s� ' � " • ,rl ,6iil�, , 1 PROPOSED HOUSE 1 28 116 VICINITY MAP 112 SECTION 22, T 8 S., R. 87 W. BASALT QUADRANGLE _ SCALE-. 1"-4000' , ) F PATIO + �- - E. I / LDISTRIDUTION GRAPHIC SCALE 8.,)X 0 5 10 20 / 11'?, GENERAL NOTES 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE _ / PITKIN COUNTY REGULATIONS OF INDIVIDUAL SEWAGE DISPOSAL IN FEET ) SYSTEMS, EVEN THOUGH ALL SUCH REQUIREMENTS ARE NOT - - SPECIFICALLY NOTED ON THE DRAWINGS. THE CONTRACTOR SHALL BE \ 1 inch = 10 (L RESPONSIBLE FOR SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN THE ABOVE-MENTIONED REGULATIONS. eau 2- FLOW: 3 BEDROOMS •2 PERSONS/BEDROOM •75 GALLONS/PERSON/DAY IS p" % ; " 225 GPD AVERAGE DAILY FLOW. 8 ,; / A,yn% DESIGN = 1.75° AVERAGE = 788 GPD (FOR A BED SYSTEM) A %;+• a o'" 8 SEPTIC TANK: MINIMUM TANK SIZE IS 1000 GALLONS. •. •FIELD SIZE: PER PITKIN COUNTY EQUATIONS: o; �� / 8 1'I ,`•, "�"• t3�r ;;�� A Q DESX � 0 - MAXIMUMGN FLOWLOW FLOW A = 788 X ' = 704 S.F. It PERC RATE 5 01 6 - - Nom" 72" „3a•n ;; PER COUNTY REOU!R-MENTS FOR USE OF "INFILTRATOR" SYSTEMS -REDUCTION 1 N IN BED, AREA = (0.7)•A AREA REQUIRED = 704 S.F. - 30% = 493 SO.FT. - •y y `'• - 0 18 SQ. FT. PER UNIT = 27 UNITS it u 3. TOPSOIL: SOIL EXCAVATED FROM SITE ACCEPTABLE IF NO CLAY IS II !j I. PRESENT. 'lt 4. VEHICULAR TRAFFIC IS PROHIBITED ON THE FIELD. 5. CLEANOUTS ARE REQUIRED AT ALL BENDS AND AT LEAST EVERY 100 108 FEET ALONG THE HOUSE SEWER. , 6. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS TO WITHIN 1/2 -FOOT OF FINAL GRADE. PROPERTY MAP Q� SCALE ^"_-.a 7. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED. X46 . 8PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM 1O� ABSORPTION AREA USING DRAINAGE SWALES AS NECESSARY. 9. PERCOLATION RATE OF 20 MPI BASED ON REPORT BY HIGH COUNTRY 1� ENGINEERING DATED JUNE 27, 1996. \ - GENERAL ABSORPTION TRENCH NOTES 10. THIS DRAWING DOES NOT CONSTITUTE AN ISDS PERMIT. PERMIT MUST BE OBTAINED FROM APPROPRIATE CITY OR COUNTY OFFICIALS. O \ 1. TRENCH LENGTH SHALL NOT EXCEED 100 FEET. 11. THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH OR Qk UNDERGROUND WATER STORAGE 2. THE BOTTOM OF EACH TRENCH SHALL BE LEVEL. FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM. 25' MIN. TO SEPTIC TANK 3 DRAINAGE DITCHES ARE TO BE PROVIDED ABOVE AND AROUND AND ABSORPTION TRENCHES TRENCHES, AS NECESSARY, TO PREVENT SURFACE RUNOFF FROM REMOVABLE CAF ENTERING ABSORPTION AREA. j/�/ Q 4. TRENCHES SHALL FOLLOW CONTOURS. J NATURAL BACKFILL \\/\ /\/• TOP OF ATOR UNIT t2" MIN. COVER `V��►11t1tl91ptJ/p>jfz j . FOR INSTALLATIONCUT OF INSPECTION TION WELL�����Q..� •Eri%j SOLID PIPE plpE •��f\ COUPLING \ j% II�,^�.r, -- 12" 0 PERFORATED PIPE //\\/\ k" M1110" NO. DATE REVISION BY A. E. LEONHARDT INFILTRATOR UNIT- I PITKIN COUNTY, COLORADO vr r INDIVIDUAL SEWAGE DISPOSAL SYSTEM NATURAL GROUND -° --- -- 36' — - --- TRENCH BOTTOM LEVEL INSPECTION WELL DETAIL AND ROUGHENED lm STONE ROAD I'' -` —� EMMA, COLORADO N. T. TRENCH CROSS SECTION TYP F4GFi COUNTRY E� Imo. --, ---- -- . 923 COOPER AVENUE N T.S GLENWOOD SPF940S, CO 81M DES. TPB CK. FILE NO. SHEET 1 16LE0 (303) 94,5-8876 -- DR. DJW (DATE 7/8/96 9&004.l6 OF 1 14S