DISTRIBYITION PIPE TO BE INSTALLED
WITH A/ MAXIMUAM/SEPARATION OF 6'
BETWEEN PDIS E TI /THE OUTSIDEI EDGE3OF BED. /
GRADE ADJAC,ENT UPGFRADIENT -
SLOPE TO DIVERT POTENTIAL
DRAINAGE -AWAY FROM FIELD /
EXISTING TREES
YOO, HEADER, PIPE
i ��TRI Eg (TYP.
/
SEWAGE UNE
FROM HOU �-
/TWA-yvAY // EXIST. GARAGE Q-
i C/L/E 0vt /
(ISTING SEPTI
T TO BE i
REMOVED
i
II PROPOSED 200 GAI
SEPTIC TAN ' W/
EFFLUENT Fl TER
(PROOSEDDIl7 / \I
EXISTING PARKING
/ / J
EXIST. HOUSE \ /
/ I
\
\ 1 I I\
GROUND SURFACE
DRAINAGE SWA I
TO KEEP RUNG
FROM THE FIELD
24' OVERALL WIDTH
OF NEW ABSORPTON
3UON UNE
NSPECTION PORT (TYP.)
lo'ADD ADDITIONAL SOLID
�4" PVC HEADER PIPE
\ ADD AN ADDITONAL 426 SF OF ABSORPTION AREA TO
EXISTING FIELD. PLACE NEW 6' WIDE BY 71' LONG
ROW OF GRAVEL AND APPROX. 65' OF PERFORATED
/ DISTRIBUTION PIPE TO PROVIDE A TOTAL OF 1704 SQ.
FT. OF ABSORPTION BED AREA. INSTALL NEW
GRAVEL AND PIPE LEVEL TO AND ADJACENT TO
/ EXISTING BED. THE EXPANDED BED MUST MEET ALL
COUNTY SETBACK REQUIREMENTS. THE EXISTING
HEADER PIPE TO BE MODIFIED TO PROVIDE FOR NEW
DISTRIBUTION PIPES FROM A NEW DISTRIBUTION BOX.
/ XI�T. DGE LOCATION OF EXISTING ABSORPTION FIELD IS
STING OF GRA EL APPROXIMATE. ACTUAL LOCATION WILL BE
ABSO 10 XIST. PERF. DETERMINED DURING CONSTUC)16N AND WILL BE
24'
F x71' DIST. PIPET\ DELINEATED ON RECORD DRAWING. SOIL
1 / \ / CONDITIONS WILL BE VERIFIED DURING
CONSRUCTION OF ADDITIONAL ABSORPTION AREA.
\ WIDTH AND LENGTH/ OF ADDITIONAL BED
/ EXISTING TREES AREA MAY BFyADJUSTED IN SYMETRIC
i � \
RELATION Tff THE EXISTING FIELD AS
LONG AS A MINIMUM OF 1704 SQ. FT.
\ OF ARjX IS PROVIDED.
/ EXISTING DRIVEWAY
FLOW SPUTTER
r i DISTRIBUTION BOX / �72 /
/
AS REQUIRED
SLOPE TO D
REVEGATATION
TOPSOIL LAYER
-2„
DIAM. PERF. PV
SCHEDULE 40 (TYP.) SCREENED BACKFILL LAYER
FILTER FABRIC NATURAL ONSITE SOILS FREE
MIRAFI N-140 BOTTOM OF BED 12" GRAVEL BED OF GRAVEL AND ROCKS IN
(OR APPROVED EQUAL) EXCESS OF 2 1/2" DIAMETER
UNDISTURBED SOIL
CROSS SECTION ABSORPTION BED DETAIL
N. T. S.
DISTRIBUTION BOX LID
AT GROUND SURFACE
110/1111 Y:N
1
a
4" DISTRIBUTION
GRAVITY LINE "SOLID PVC GRAVITY
FROM SEPTIC TANK NVERT IN DISTRIBUTION LATERALS (TYP.)
TO ABSORPTION TRENCHES
FLOW SPLITTER BASIN DETAIL
N.T.S.
TWO WAY CLEAN OUT
PROPOSED GRADE—
EXISTING GRADE
EFFLUENT FILTER �\
OU=ET TEE \
EFFLUENT DISCHARGE LINE
AT MINIMUM 2% SLOPE
FLOW SPITTER BASIN
DISTRIBUTION LINES
AT MINIMUM 27 SLOPE
PROPOSED HOUSE
-EFFLUENT DRAIN LINE
AT MINIMUM 2% SLOPE
TANK
CROSS SECTION SLOPE DETAIL
N.T.S.
GENERAL NOTES:
1. THE OWS SYSTEM AS SHOWN ON THE PLAN AND THE DETAILS WERE
DESIGNED BY SOPRIS ENGINEERING. THE EXISTING LOT CONDITIONS
AND SURVEY INFORMATION WAS PROVIDED FROM A SURVEY
BY ASPEN SURVERY ENGINNERS.
2. THE CONTOUR INTERVAL ON THIS MAP IS 2 FEET.
23046.01 23048-OW,.MVC 15/12/03
ISDS SYSTEM NOTES
1. ADD A TWO-WAY CLEAN OUT ON THE SERVICE LINE FROM THE HOUSE.
2. ALL MATERIALS AND INSTALLATION SHALL CONFORM TO PITKIN COUNTY
INDIVIDUAL SEWAGE DISPOSAL SYSTEM (ISDS) REGULATIONS.
3. ALL SEWER LINES TO BE SDR -35 OR SCHEDULE 40 P.V.C. PIPE UNLESS
NOTED OTHERWISE.
4. THE CONTRACTOR SHALL ENSURE ALL SEWER LINES AND SEPTIC TANKS
ARE WATERTIGHT. ANY POTENTIAL PLUMBING LEAKS SHALL BE
REPAIRED TO AVOID EXCESSIVE WATER ENTERING THE SEPTIC SYSTEM.
5. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CONTACT ALL
UTILITY COMPANIES FOR FIELD LOCATIONS OF UTILITIES PRIOR TO
CONSTRUCTION AND EXCAVATION.
6, THE ABSORPTION FIELD MUST BE MARKED AND PROTECTED TO
PREVENT DAMAGE FROM VEHICULAR AND LIVESTOCK TRAFFIC.
7. THE TANK SHALL BE INSTALLED LEVEL ON COMPACTED EARTH. INSTALL
WATERTIGHT RISERS AS NECESSARY TO BRING ALL REQUIRED ACCESS
POINTS TO THE FINISHED SURFACE GRADE.
INSTALL THE INLET AND OUTLET TEES TO BE EASILY INSPECTED AND
MAINTAINED FROM THE TANK RISERS AND ACCESS LIDS.
8. THE ENTIRE ABSORPTION FIELD SURFACE MUST BE SODDED OR
RE -VEGETATED WITH GROUND COVER,
9. THE ABSORPTION FIELD SURFACE MUST BE GRADED TO DIVERT
SURFACE DRAINAGE AWAY FROM THE FIELD.
10. THE DIMENSIONS SHOWN ON THE PLAN INDICATE MINIMUM AREA AND
SEPARATION DISTANCES FOR THE ABSORPTION FIELD.
11. THE FIELD SHALL BE LEVEL AND PLUMBED FOR EQUAL
DISTRIBUTION. THE ADDITIONAL ABSORPTION FIELD AREA TO BE
INSTALLED ADJACENT TO THE EXISTING FIELD AT THE SAME LEVEL.
12. THE MINIMUM DEPTH OF GRAVEL TO BE 12" OR MATCH EXISTING FIELD IF
GREATER. THE UPGRADIENT SLOPE ADJACENT TO THE FIELD TO BE
GRADED TO DIVERT POTENTIAL RUNOFF AWAY FROM THE FIELD.
13. THE PIPE AND GRAVEL BED WILL BE BACKFILLED WITH EXCAVATED
MATERIAL VOID OF ROCKS, THE BACKFILL MATERIAL SHALL NOT EXCEED
2 1/2" DIAMETER AND SHALL BE PLACED TO AT LEAST 6 INCHES ABOVE
THE TOP OF THE GRAVEL. THE TOP OF THE PLACED GRAVEL DISTRIBUTION
LAYER SHALL BE COVERED WITH A LAYER OF FILTER FABRIC. A
MINIMUM 4" DEPTH OF TOPSOIL IS TO BE PLACED ABOVE THE BACKFILL
TO THE SURFACE. THE EXISTING FIELD GRAVEL SHALL BE REPLACED AS
NEEDED IF CONTAMINATION BY EXCAVATED BACKFILL OCCURS.
14. VERTICAL INSPECTION PORTS SHALL BE INSTALLED FROM THE ENDS OF
THE PERFORATED DISTRIBUTION PIPE INSTALLED IN THE NEW ABSORPTION
AREA. (TYP. EACH END). AN ADDITIONAL INSPECTION PORT TO BE
INSTALLED AT THE HEAD OF THE OPPOSITE SIDE OF THE FIELD.
15, THE CONDITION OF THE EXISTING FIELD TO BE INSPECTED DURING
INSTALLATION OF NEW DISTRIBUTION LINES TO THE HEAD OF EACH
EXISTING PERFORATED DISTRIBUTION PIPE.
DISTRIBUTION SYSTEM NOTES:
1. AN EFFLUENT FILTER SHALL BE INSTALLED,QAI- THE...DISCHARE TEE
IN THE SECONDARY COMPARTMENT OF THE.,1000 GAL+ SEPTIC TANK.
FILTERED EFFLUENT WILL DISCHARGE TO A DISTRIBUTION BOX.
EFFLUENT WILL BE EQUALLY DISTRIBUTED TO THE ABSORPTION
BED'S PERFORATED DISTRIBUTION PIPES VIA INDIVIDUAL 4" DISTRIBUTION
LINES.
2. WE RECOMMEND THE INSTALLATION OF AN ORENCO SYSTEMS 4"
EFFLUENT FILTER CONTAINED IN A 4" BAFFLE OUTLET TEE.
THE FILTER SHOULD BE INSPECTED EVERY SIX MONTHS.
MAINTENANCE SHALL INCLUDE CLEANING THE FILTER EVERY SIX
MONTHS MINIMUM AND AFTER PERIODIC PUMPING OF THE TANK.
3. THE DISTRIBUTION SYSTEM SHALL DISTRIBUTE FLOW EVENLY TO
EACH BED ROW. THE MINIMUM SLOPE OF THE
DISCHARGE LINE FROM THE TANK TO THE DISTRIBUTION BOX
SHALL SHALL BE INSTALLED AT A MINIMUM 2% SLOPE. THE
INDIVIDUAL DISTRIBUTION LINES SHALL BE INSTALLED AT A
MINIMUM OF 2% SLOPE.
4. ALL DISTRIBUTION PIPING, CONNECTIONS AND FITTINGS SHALL BE
TIGHT AND INSTALLED TO INSURE EQUAL DISTRIBUTION
THROUGH THE SYSTEM.
ADDITIONAL NOTES:
1. THE PERFORATED DISTRIBUTION LINES IN THE MOUND NEED TO
BE LAID IN A 12" LAYER OF WASHED GRAVEL WITH DIAMETERS
BETWEEN 0.75" AND 1.5".
2. THE PERFORATED PIPES NEED TO BE LAID WITH THE TOP OF PIPE
2" BELOW THE TOP OF THE GRAVEL LAYER AND WITH AT LEAST
6" OF GRAVEL BELOW THE BOTTOM OF THE PIPES.
3. A MINIMUM OF 2' OF SUITABLE ONSITE MATERIAL, NEEDS TO BE
PLACED BELOW THE GRAVEL DISTRIBUTION LAYER IF LARGE
BOULDERS ARE ENCOUNTERED THAT NEED TO BE REMOVED..
4 THE DISTRIBUTION BOX WILL BE INSTALLED TO INSURE EQUAL
DISTRIBUTION TO THE BED'S PERFORATED DISTIBUTION PIPES.
WE RECOMMEND THE INSTALLATION OF AN ORNECO SYSTEMS FLOW
SPLITTER BASIN WITH THE RISER EXTENDING TO THE SURFACE.
5. GRAVEL AND FILL MATERIALS TO BE APPROVED BY THE ENGINEER.
OPRIS ENGINEERING, LLC.
502 MAIN STREET, SUITE A3
CARBONDALE, CO 81623
(970) 704-0311
NO.1 DATE I REVISION BY
LOTS 2 & 3 NYSTROM SUBDIVISION
909 W. SOPRIS CREEK ROAD
PITKIN COUNTY, COLORADO
KELLY OWS SYSTEM
ONSITE WASTEWATER SYSTEM
SITE PLAN AND SYSTEM DETAILS
DES. PER CK. YTN I FILE NO. 1OF
SHEET 1
DR. PER DATE 5/12/03 23046.01 1