11
0
Pitkin County Environmental Health Department
Permit for an Individual Sewage Disposal System
0405 Castle Creek Road, Suite 10, Aspen, Colorado 81611
Phone 970-920-5070 / FAX 970-920-5077
REPLACES PERMIT 04050
Permit# 05044 Parcel ID# 2465-331-01-005
Type of permit New( x ) Repair( ) Addition/Remodel to House( )
Name of Owner Robert Mandich
Street Address 0805 Sopris Mt. Ranch RA
Property legal description Lot 30, Sopris Mountain Ranch
Size of lot 35+ acres
Water source Private Well
Total square footage of the house 5508
# of bedrooms in house 4 # of offices, lofts & similar sized rooms in house
Caretaker unit Total square footage of the caretaker unit
# of bedrooms in caretaker unit # of offices, lofts & similar sized rooms in caretaker unit
Designed for what # rooms (list) (4) FOUR bedrooms
Permit information
Designed by Pinnacle Design Consulting Group
Mailing Address 0232 Woods Rd, Aspen CO 81612
Perc rate 22 Profile hole depth 8ft Depth to groundwater or bedrock <8 ft
Minimum Septic tank capacity 1.750 gallon Minimum Absorption area 1313 sq
Comments
Septic permit approved per compliance with the engineer revised design and specifications stamped and dated
7/8/05 based on new perc rates. Any changes must be approved by this department and the design engineer prior
to them being made. Minimum horizontal distances between components of the system and physical features shall
conform to the Pitkin County ISDS regulations.
Design is for one 1000 gallon single compartment concrete septic tank followed by a 1000 gallon two compartment
concrete septic tank with a Biotube effluent filter. A flow splitter basin distributes the flow to two beds of standard
gravelless chambers, each bed is 6 rows of 8 chambers for a total of 96 chambers.
This department does not endorse any brand of products. This permit must be kept on-site during installation.
The engineer must do a final inspection of the installation and submit an as -built letter to this department. This
department must also be called for an inspection with a minimum of 48 hours advanced notice.
'Revegetation over the area of the field is very important for the functioning of the system. Pitkin County has guidelines that must be
followed to assure the plants that are introduced are appropriate for the conditions of the area. The use of native plants is strongly
Permit approved by: e Date:
Plans and specifications of the prb osed individual sewage disposal system have been reviewed and are considered
satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin
County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was
l�sued} Ness system construction has commenced or an extension has been approved in writing by the Department.
_S�
As -built drawings must be included with this permit before the final approval will be issued. 1
Installer: V�—
lFinal approval: /1�� Date: 7 eb
'- - 04,�C eo-- A4-47u-Q't.,-ry,'f-> 4= �' L , y1,p
0 a
Pitkin County Environmental Health Department
Permit for an Individual Sewage Disposal System
0405 Castle Creek Road, Suite 10, Aspen, Colorado 81611
Phone 970-920-5070 / FAX 970-920-5077
Permit# 04050 ParcelID# 2465-331-01-005
Type of permit New(x ) Repair( ) Addition/Remodel to House( )
Name of Owner Robert Mandich
Street Address 0805 Sopris Mt. Ranch
Property legal description Lot 30, Sopris Mountain Ranch
Size of lot 35+ acres Total square footage of the house 5508
Water source Private Well
# of bedrooms in house 4 # of offices, lofts & similar sized rooms in house
Caretaker unit Total square footage of the caretaker unit
# of bedrooms in caretaker unit # of offices, lofts & similar siz rooms i
aretaker unit
Designed for what # rooms (list) (4) FOUR bedrooms
Permitinformatio
D'
�I
Designed by Pinnacle Design Consultin -
Mailing Address 0232 Woods Rd, Ase 81612
Perc rate 200 Profile hole depthft Depth to gro dwater or bedrock
<8 ft
Minimum Septic tank capacity ,750 gallon Minimum bsorption area
'see engineer design
Comments
Septic permit approved per complia ce with th ngineer design nd specifications stamped 7/15/04. Any
changes must b approved by this deVartment an the designngineer prior to them being made. Minimum
horizontal distanco between compon6rits of the sy physical features shall conform to the Pitkin County
ISDS regulations
Design is for one 1000 ga n single compment concrete septic tank followed by a 1000 gallon two compartment
concrete septic tank with a Bi be pump v It, a duplex pumping system a distribution valve vault, and a 23,424
sq ft drip irrigation field.
This department does not endorse any%ndp oducts. This permit must be kept on-site during installation.
The engineer must do a final inspectionstallation and submit an as -built letter to this department. This
department must also be called for an iwith a minimum of 48 hours advanced notice.
'Revegetation over the area of the field is very important far the functioning of the system. Pitkin County has guidelines that must be
followed to assure the plants that are introduced are appropriate for the conditions of the area. The use of native plants is strongly
Permit approved by: , Date:_��
Plans and specifications of the proposed individual sewage disposal system have been reviewed and are considered
satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin
County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was
issued unless system construction has commenced or an extension has been approved in writing by the Department.
As -built drawings must be included with this permit before the final approval will be issued.
Installer:
Final approval: Date:
PITKIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM
0405 Castle Creek Road, Suite 10, Aspen Colorado 81611
Phone (970) 920-5070 Fax (970) 920-5077
Name of OWNER
Owners Mailing Address ot
City, State, Zi , 2 Business Phone: -(
Home Phone: Z E-mail Address:
Primary Contact Person (all communication regarding this permit will go through this person)
Name J
Company 4 l �
Contact Mailing Address 6oX
City, State, Zi l_D K L % �Z Business Phone: C�ItZ
Cell Phone: = z Fax :`(,Z E-mail Address:
Parcel ID # (available from assessor's officeII
at 920-5160 or at www.pitkinassessor.org) �- c3 ' _ _ 1 -__
Street address of property 7-S D. o g0 5
Legal Description: Lot ,Block Filing Subdivision
Size of lot: -t acres. �2 Type of proposed structure: RAS t p��t AL
Total square feet of house Z5�0S # of bedrooms (potential) in house -14
Caretaker Unit: Attached ( ) Detached ( ) t-?
of
# of
'A
Permit is for: New Home (X-�, Repair due to failure ( ) Remodel/Addition ( ) Emergency use ( )
Water: Private well (� ) Spring ( ) Stream ( ) Community/Public Water System ( )
If community system: Name of system
The fee for a ISDS application is $600 for a permit that takes 6 hours or less for the department to approve. If approval takes
longer than 6 hours, a rate of $100 per hour will be charged. The maximum fee is $1000. The basic fee of $600 is due at the
time of application. The remainder, if any, will be due in two stages: first, at the time of issuance of the ISDS permit; second,
before final approval of the ISDS permit.
Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information is true and
accurate and that I have provided true and accurate information on locations of all existing and proposed wells, contour
intervals, buildings, property lines, ditches, slopes, waterlines, springs, suction or irrigation lines, drinking water cisterns, drain
tiles, irrigation ditches, lakes, water courses, streams, floodplains, dry gulches, and existing septic systems. I hereby certify
that any such features not shown on attached site map are not present. Issuance of the permit does not imply the approval of
any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all
approvals and permits have been obtained.
The Pitkin County Environmental Health Department, Pitkin County and employees of these agencies will be held harmless
should the individual sewage disposal syste uPAAiQn. The permit to construct is issued on information submitted by
the applicant or his/her repres�tatwya�Pecg sumes ful onsibility in case of failure of the system.
Signature of applicant
Received by
IG9sds\isds applic\isdsapp Rev050103.doc
J
tj 13100 /
Date
7 /�Xrj
Receipt # / Data
7 N .�
---------------------------------
REASON FOR ERROR
E-3) NONANS.E UP OR LINE FAIL
• •
------------------------------
E -'1I SUSY
E-4) NO FACSIMILE CONNECTION
PITIQN COUNTY ENVIRONMENTAL HEALTH & NATURAL RESOURCES
DATE: 11/8/2006
Send to: Robert Mandich From: Alicia Gomez
Fax Number: 925-9173 Phone Number: 920-5087
CC: Pinnacle Design consulting Group Number of Pages, including Cover. 2
CC Fax Number: 704-0215
O URGENT O REPLY ASAP 0 PLEASE COMMENT a PLEASE REVIEW ® FOR YOUR
INFORMATION
COMMENTS:
Septic Permit #05044 for parcel 2465-331-01-005, owner
Mandich, has been finalized
you have any questions.
fax cover
Please feel free to call 920-5070 if
Pitkin County Environments] Health and Natural Resources
0405 Castle Creek Road Suite #10, Aspen, CO 81611.
Phone (970) 920.5070 i Fax (970) 920_5077
Web site v .aspenpitkin_com/ehnr
P. 1
x
t t COMIGICATION
RESULT REPORT
( NOV. 8.246 8:49AM )
t t
x
FAX HEADER: ENVIRO
HEALTH
NAT RESOURCE
TRANSMITTED/STORED
NOV. 8.2006 8:46AM
FILE MODE
-------------------------------------------------------------------------------------------------
OPTION
ADDRESS
RESULT
PAGE
772 MEMORY TX
9259173
OK
2/2
7040215
OK
2/2
---------------------------------
REASON FOR ERROR
E-3) NONANS.E UP OR LINE FAIL
• •
------------------------------
E -'1I SUSY
E-4) NO FACSIMILE CONNECTION
PITIQN COUNTY ENVIRONMENTAL HEALTH & NATURAL RESOURCES
DATE: 11/8/2006
Send to: Robert Mandich From: Alicia Gomez
Fax Number: 925-9173 Phone Number: 920-5087
CC: Pinnacle Design consulting Group Number of Pages, including Cover. 2
CC Fax Number: 704-0215
O URGENT O REPLY ASAP 0 PLEASE COMMENT a PLEASE REVIEW ® FOR YOUR
INFORMATION
COMMENTS:
Septic Permit #05044 for parcel 2465-331-01-005, owner
Mandich, has been finalized
you have any questions.
fax cover
Please feel free to call 920-5070 if
Pitkin County Environments] Health and Natural Resources
0405 Castle Creek Road Suite #10, Aspen, CO 81611.
Phone (970) 920.5070 i Fax (970) 920_5077
Web site v .aspenpitkin_com/ehnr
C
October 19, 2006
•
PINNACLE DESIGN
CONSULTING GROUP, INC.
Mrs. Nancy MacKenzie 0005 BUCKPOINT ROAD .
0405 Castle Creek Road, Suite 10 CARBONDALE, CO 0762
Aspen, Colorado 81611 970-963-2170.970.7040215 FAX
RE: CERTIFICATION OF SOPRIS MOUNTAIN RANCH PARCEL 30
ISDS PERMIT # 05044
Dear Nancy:
This letter represents construction certification of Sopris Mountain Ranch, Parcel 30
ISDS pursuant to the plans and specifications prepared by Pinnacle Design Consulting
Group, Inc.
The Parcel 30 ISDS was installed under the Pitkin County Environmental Health
Department ISDS Permit Number 05044, on file with your records.
The new ISDS system was designed to serve the recently completed residence located in
unincorporated Pitkin County. The drain fields were designed as a gravel -less chamber
beds and were separated into two separate fields as depicted on the "drawing of record"
plan included herewith. I personally inspected the installation of the gravel -less
chambers, septic tanks, distribution box, and effluent piping. I observed the installation
of the system including site preparation, septic tanks, gravel -less chambers, and manifold
piping as shown on our plan and detail sheets.
The enclosed "drawing of record" plan represents the proposed ISDS improvements with
respect to the subject residence.
I trust that this letter provides adequate certification of the Parcel 30, Sopris Mountain
Ranch ISDS installation pursuant to the plans and specifications prepared by my firm.
Please feel free to contact me if you have any questions.
Sincerely,
Hans E. Brucker, PE
PINNACLE DESIGN
CONSULTING GROUP, INC.
HEB/heb
Enclosures:
LD
• • Page 1 of 2
Nancy Mackenzie
From: pinnacledesign@sopds.net
Sent: Wednesday, October 25, 2006 7:45 PM
To: Nancy Mackenzie
Subject: Re: Lot 30 Sopris Mt Ranch Mandich
Nancy;
1. I did not take any pictures of the distribution box. However, it has an access manway on top of it so it is still accessible.
2. The installer was Metcalf Concrete. Jason Metcalf is the owner. He runs an excavation business as part of his concrete
business, which is based in New Castle, Colorado.
3. The system was installed in the fall of 2005. I believe sometime in October. The photos that I took were developed from a
disposable camera and therefore were not dated until March of 2006 when I needed other photos from the same camera for
another septic system asbuilt drawing.
Give me a call on my cell phone at 618-4427 if you have any other questions or need any other information.
Hans E. Brucker, PE
----- Original Message -----
From: Nancy Mackenzie
To: pinnacledesigrtna.sonris.net
Sent: Tuesday, October 24, 2006 9:18 AM
Subject: RE: Lot 30 Sopris Mt Ranch Mandich
Hans,
1) Do you have any pictures of the Distribution box?
2) Who was the installer
3) What the approximate date.of the installation
The pictures of the bed are good. Thanks
Nancy
No virus found in this incoming message.
Checked by AVG Free Edition.
11/7/2006
_:.
k , c��y,'-..
' �_�1r
i
rms
@mo aI �'��
I
Ll
July 8, 2005
Nancy MacKenzie
Pitkin County Environmental Health Dept.
0405 Castle Creek Road
Aspen, Colorado 81611
RE: PARCEL 30 - SOPRIS MOUNTAIN RANCH
REVISED SEPTIC SYSTEM DESIGN
Dear Nancy;
F
PINNACLE DESIGN
CONSULTING GROUP, INC.
0803 BUCK POINT ROAD . ASPEN, CO
81812
870.983-2170.970.7040215 FAX
Enclosed please fmd a revised OWS plan and calculations for the Parcel 30 of the Sopris
Mountain Ranch. As you know, we conducted percolation tests in an alternate area and
obtained better absorption results than the original percolation test conducted by HP
Geotech.
The alternate test locations seemed to contain more alluvial deposits and less clay than
the original percolation test holes.
Our percolation test results and revised system calculations are shown on Sheet 2 of 2
enclosed
Please feel free to give us a call if you have any questions or comments or require any
additional information.
Sincerely,
Hans E. Brucker, PE
PINNACLE DESIGN
CONSULTING GROUP, INC.
HEB/heb
Enclosures:
1U
RECEIVED
""1 0 8 2005
Pt F)(44 COUNTY
ENV ' V#1ENTA1 HEALTH
0
July 14, 2004
0
PINNACLE DESIGN
CONSULTING GROUP, INC.
0232 WOODS ROAD. ASPEN, CO 61612
Nancy MacKenzie 970.923-9495.970-923-9694 FAX
Pitkin County Environmental Health Dept. 96 -.211760405 Castle Creek Road
Aspen, Colorado 81611
RE: SOPRIS MOUNTAIN RANCH - LOT 30 OWS MODIFICATIONAS
Dear Nancy,
Enclosed are two copies of the revised OWS for the subject parcel. We have modified
the drain field in accordance with the standards from the Tri -County Health Department
for drip irrigation systems. We used an allowable application rate (R), in this case, of
0.06 gal/sflday which is based on an infiltration rate of 0.01 gal/sf/day and an evaporation
rate of 0.05 gaUsf/day (assuming 32" of evaporation per year). The calculations have
been shown on the new set of plans.
Please feel free to give me a call if you have any questions or comments concerning this
matter.
Sincerely,
f
Hans E. Brucker, PE
PINNACLE DESIGN
CONSULTING GROUP, INC.
HEB/heb
Enclosures:
RECEIVED
JUL 1 5 M4
PITKIN COUN i
ENVIRONMENTAL HEALTH
Warren Brown, 12:05 PM 6/8/2004, Fes: Water Balance Spreadsheets for sizi4vapotranspiration sy Page 1 of 2
From: "Warren Brown" <wbrown@tchd.org>
To: "Nancy MacKenzie \(E-mail\)" <nancym@ci.aspen.co.us>
Subject: FW: Water Balance Spreadsheets for sizing evapotranspiration systems
Date: Tue, 8 Jun 2004 12:05:02 -0600
X -Mailer: Microsoft Outlook CWS, Build 9.0.2416 (9.0.2911.0)
Importance: Normal
X -MX -Spam: exempt
X -MX -MAIL -FROM: <wbrown@tchd.org>
X -MX -SOURCE -IP: [216.58.160.44]
X-MailScanner-Information: Please contact the ISP for more information
X-MailScanner: Found to be clean
Nancy: I am forwarding you my email to Hans. Warren
-----Original Message -----
From: Warren Brown [mailto:wbrown@tchd.org]
Sent: Tuesday, June 08, 2004 12:03 PM
To: Hans Brucker (E-mail)
Subject: Water Balance Spreadsheets for sizing evapotranspiration systems
June 8, 2004
Hans:
Attached, please find the water balance spreadsheets. Section VIII C. d.
(2) on Page 26 of the State Guidelines on ISDS has a Long Term Acceptance
Rate of 0.20 gallons/sq.ft./day for percolation rates in excess of 60
minutes per inch; however, I recommend 0.10 gallons/day/square foot for
percolation rates in excess of 120 minutes per inch.
Section VIII C. 4 g. and h. discuss requirements for sizing ET beds -Use the
formula or the water balance method.
I will also fax you the information on the design of drip irrigation
systems. Keep in mind that Pitkin County may require a different equation
and loading rates than indicated in the information I will fax you.
Please call if you have questions.
Warren S. Brown, P.E.
Public Health Engineer
Tri -County Health Department
7000 E. Belleview Avenue
Suite 301
Greenwood Village, CO 80111-1628
Phone: (303) 846-6225
Fax: (303) 220-9208
wbrown@tchd.org
is
Printed for Nancy MacKenzie <nancym@co.pitkin.co.us>
6/8/2004
ASPEN/PITKIN ENANMENTAL HEALTH DEPARIONT
ISDS DESIGN CALCULATIONS
Owner's Name Mandich Parcel ID # -
House Size (sq. ft.) 48W (75 gpd,100 gpd, or 130 gpd) 100
Number of Bedrooms in Main House 4
Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House
Number of Bedrooms in Detached Caretaker unit
Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit
(If the caretaker unit is ATTACHED, treat as if part of main house.)
Average Daily Waste Flow 800
State Review Required? no
Perc Rate 200 (F)
Design Flow (Q) = # potential bedrooms X 2 people/ bedroom X gpd X 1.75
Q= 1400
Absorption Area (=Q/5 X SQRT perc rate)
A = 3959.798 sq. ft. of absorption area required
255 gravelless chamber units without reduction
# of Perc Holes Required: 3.2998316
1 in every soil type? Spaced uniformly over proposed area?
A nmrimum 30% reduction is allowed for use of deep gravel or gravelless chambered system,
only if the lot size and soil conditions are optimal.
If a reduction is being proposed, describe why lot size and soil conditions are optimal:
A = 2771.8586 sq.ft. w/30% bed reduction 1979.89899 sq.ft. w/ 50% trench reduction
179 gravelless chamber units 128 gravelless chamber units
Type of system: OAbsorption trenches []Absorption bed [] Gravelless chambers
[]Dry well OSeepage Pit []Other (type)
Minimum tank capacity 1750 gallon%
SETBACK FROM WELL
# of feet = 132
SETBACK FROM POND, STREAM OR IRRIGATION DITCH
# of feet = 82
SETBACK FROM DRY GULCH
# of feet = 57
/ , � Printed on Recycled Paper
PITKIN ENVIRORMENTAL HEALTH DEPARTMEO
ISDS DESIGN CALCULATIONS
Owner's Name Parcel ID # !'
House Size (sq. ft.) (75 gpd, 100 gpd, or 130 gpd) 100
Number of Bedrooms in Main House
Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House
Number of Bedrooms in Detached Caretaker unit
Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit
(If the caretaker unit is ATTACHED, treat as if part of main house.)
Average Daily rite Flow
State Review/Required?
Perc Rate (T)
Design Flow (Q) = # potential bedrooms X 2 people/bedroom X gpd X 1.75
Q= 1400
Minimum tank capacity 1750 gallons
Absorption Area (=Q/5 X SQRT perc rate)
A = 1313.3164 sq. ft. of absorption area required
85 gravelless chamber units without reduction
# of Perc Holes Required: 3
1 in every soil type? Spaced uniformly over proposed area?
QUICK 4 9_8
A = 656.65821 sq.ft. with 5o% reductionTRENCHEs
67 gravelless chamber units with reduction
STANDARD
A— 656.65821 sq.ft with 5o% reductionTRENCHES
42 gravelless chamber units with reduction
EQ 36
41 EQ36 units in TRENCHES
SETBACK FROM WELL
# of feet = 132
SETBACK FROM POND, STREAM OR IRRIGATION DITCH
# of feet = 82
SETBACK FROM DRY GULCH
# of feet = 57
I LI
DICK 4 9.2
919.32149 sq ft 30% reduction BED
100 chamber units with reduc.
919.32149 sq ft 30% reduction BED
59 chamber units with red=.
74 EQ36 units in a BED
L
�J
" rAech
HEPWORTH-PAWLAK GEOTECHNICAL
, August 6, 2003
Mandron Group
Attn: Bob Mandich
P.O. Box 7964
Hepworth-Pawlak Geotecimicad, Inc.
5020 County Rout 154
Glenkvwd Springs, C ,Iorido 51601
Phone: 970.945-7958
Fax: 970-945-6454
email: hpgw@hpgentech.com
Aspen, Colorado 81621 Job No. 103 469
Subject: Preliminary Subsoil Study for Foundation Design and Percolation
Testing, Proposed Residence, Lot 30, Sopris Mountain Ranch, Pitkin
County, Colorado
Dear Mr. Mandich:
As requested, Hepworth-Pawlak Geotechnical, Inc. performed a subsoil study and
percolation testing for preliminary foundation and septic disposal designs at the subject
site. The study was conducted in accordance with our agreement for geotechnical
engineering services to you dated July 21, 2003. The data obtained and our
recommendations based on the proposed construction and subsurface conditions
encountered are presented in this report.
Proposed Construction: Design plans for development of the lot were conceptual at the
time of this study. We understand that the proposed residence will be a single family
residence with a full basement level located in the area of the exploratory boring and
pits shown on Figure 1. Ground floors could be slab -on -grade or structural above
crawlspace. Cut depths are assumed to range between about 4 to 10 feet. Foundation
loadings are assumed to be relatively light and typical of the proposed type of
construction. The septic disposal system is proposed to be located northeast and
downhill of the proposed residence. The irrigation ditch is proposed to be relocated
around the building footprint.
If building conditions or foundation loadings are significantly different from those
described above, we should be notified to re-evaluate the recommendations presented in
this report.
Site Conditions: The lot was vacant at the time of our field exploration and is located to
the south and uphill of the subdivision road which crosses the north end of the lot. The
building area is accessed via a rough graded dirt road. A live irrigation ditch flows
northeast through the proposed building footprint and continues along the east side of
the building envelope. The ground surface in the building envelope is irregular but
mostly flat with typically a moderate slope down to the northeast. Vegetation consists
Parker 303-841-7119 ® Colorado Springs 719-633-5562 9 Silverthorne 970-468-1989
Mandron Group
August 6, 2003
Page 2
of grass and weeds with sage and oak brush. Scattered cobbles and boulders were
observed on the ground surface.
Subsurface Conditions: The subsurface conditions at the site were evaluated by
drilling one exploratory boring, and excavating two exploratory pits in the building area
and one profile pit in the septic disposal area at the approximate locations shown on
Figure 1. The logs of the boring and pits are presented on Figure 2. The subsoils
encountered, below about 1 foot of organic topsoil, consist of a shallow depth of stiff to
very stiff sandy clay with scattered rock fragments up to cobbles size overlying dense
gravel, cobble and boulder size rock fragments in a sandy clay matrix down to the
maximum explored depth of 6 to 8 feet. Results of swell -consolidation testing
performed on relatively undisturbed samples of the upper sandy clay, presented on
Figures 4 and 5, indicate low compressibility under existing moisture conditions and
light loading and high expansion potential when wetted. Results of a gradation analysis
performed on a sample of the underlying gravel and cobble rock fragments (minus 6
inch fraction) obtained from Pit 2 are presented on Figure 6. The laboratory test results
are summarized in Table 1. No free water was observed in the boring or pits at the
time of drilling or excavation and the soils were slightly moist to moist.
Foundation Recommendations: Considering the subsoil conditions encountered in the
exploratory boring and pits, and the nature of the proposed construction, we
recommend spread footings placed on the natural coarse granular subsoils and designed
for an allowable soil bearing pressure of 3,000 psf for support of the proposed
residence. Footings may need to be designed for a minimum dead load if expansive
soils are encountered in footing areas. Due to the variable nature and settlementfheave
potential of the subsoils, bearing conditions in footing areas should be evaluated at the
time of construction. Footings should be a minimum width of 16 inches for continuous
walls and 2 feet for columns. The upper clay soils and loose disturbed soils
encountered at the foundation bearing level within the excavation should be removed to
expose the undisturbed natural soils. Exterior footings should be provided with
adequate cover above their bearing elevations for frost protection. Placement of
footings at least 42 inches below the exterior grade is typically used in this area.
Continuous foundation walls should be reinforced top and bottom to span local
anomalies such as by assuming an unsupported length of at least 10 feet. Foundation
walls acting as retaining structures should be designed to resist a lateral earth pressure
based on an equivalent fluid unit weight of at least 55 pcf for the on-site granular soil as
backfill. Rock larger than about 6 inches, topsoil and clay soils should not be included
in the backfill.
Job #103 469
C�teCh
I��
0
Mandron Group
August 6, 2003
Page 3
Floor Slabs: Due to the variable settlement/heave potential of the subsoils, the
feasibility of slab -on -grade construction should be evaluated at the time of construction.
Structural floors over a crawlspace are commonly used where expansive subgrade soils
are encountered. The following recommendations should be followed if slabs -on -grade
are proposed.
To reduce the effects of some differential movement, interior slabs should be separated
from all bearing walls and columns with expansion joints which allow unrestrained
vertical movement. Floor slab control joints should be used to reduce damage due to
shrinkage cracking. The requirements for joint spacing and slab reinforcement should
be established by the designer based on experience and the intended slab use. A
minimum 4 -inch layer of free -draining gravel should be placed beneath basement level
slabs to facilitate drainage. This material should consist of minus 2 -inch aggregate with
less than 50% passing the No. 4 sieve and less than 2% passing the No. 200 sieve.
All fill materials for support of floor slabs should be compacted to at least 95% of
maximum standard Proctor density at a moisture content near optimum. Required fill
can consist of the on-site granular soils devoid of vegetation, topsoil, and rock larger
than about 6 inches or road base.
Underdrain System: Although free water was not encountered during our exploration,
it has been our experience in the area that local perched groundwater can develop
during times of heavy precipitation or seasonal runoff. Frozen ground during spring
runoff can create a perched condition. We recommend below -grade construction, such
as retaining walls, crawlspace and basement areas, be protected from wetting and
hydrostatic pressure buildup by an underdrain system.
The drains should consist of drainpipe placed in the bottom of the wall backfill
surrounded above the invert level with free -draining granular material. The drain
should be placed at each level of excavation and at least 1 foot below lowest adjacent
finish grade and sloped at a minimum 1 % to a suitable gravity outlet. Free -draining
granular material used in the underdrain system should contain less than 2% passing the
No. 200 sieve, less than 50% passing the No. 4 sieve and have a maximum size of
2 inches. The drain gravel backfill should be at least 11/2 feet deep.
Surface Drainage: The following drainage precautions should be observed during
construction and maintained at all times after the residence has been completed:
1) Inundation of the foundation excavations and underslab areas should be
Job #1 03 469
0
Mandron Group
August 6, 2003
Page 4
avoided during construction. Drying could increase the expansion
potential of the clay soils.
2) Exterior backfill should be adjusted to near optimum moisture and
compacted to at least 95% of the maximum standard Proctor density in
pavement and slab areas and to at least 90% of the maximum standard
Proctor density in landscape areas. Free -draining wall backfill should be
capped with about 2 feet of the on-site, finer graded soils to reduce
surface water infiltration.
3) The ground surface surrounding the exterior of the building should be
sloped to drain away from the foundation in all directions. We
recommend a minimum slope of 12 inches in the fust 10 feet in unpaved
areas and a minimum slope of 3 inches in the first 10 feet in pavement
and walkway areas. A swale may be needed uphill to direct surface
runoff around the residence.
4) Roof downspouts and drains should discharge well beyond the limits of
all backfill.
5) Landscaping which requires regular heavy irrigation should be located at
least 10 feet from the building. Consideration should be given to the use
of xeriscape to limit potential wetting of soils below the building caused
by irrigation.
Percolation Testing: Percolation tests were conducted on July 25, 2003 to evaluate the
feasibility of an infiltration septic disposal system at the location designated by Mr.
Mandich. One profile pit and three percolation holes were dug at the locations shown
on Figure 1. The test holes (nominal 12 inch diameter by 12 inch deep) were hand dug
at the bottom of shallow backhoe pits and were soaked with water one day prior to
testing. The soils exposed in the percolation holes are similar to those exposed in the
Profile Pit shown on Figure 2 and consist of dense gravel and cobble rock fragments in
a sandy clay matrix. Percolation testing indicates infiltration rates of 120 to 240
minutes per inch. The percolation test results are presented in Table 2. A civil
engineer should design the infiltration septic disposal system.
Limitations: This study has been conducted in accordance with generally accepted
geotechnical engineering principles and practices in this area at this time. We make no
warranty either express or implied. The conclusions and recommendations submitted in
this report are based upon the data obtained from the exploratory boring and pits located
as shown on Figure 1, the proposed type of construction and our experience in the area.
Our findings include interpolation and extrapolation of the subsurface conditions
Job #103 469
E
Mandron Group
August 6, 2003
Page 5
identified at the exploratory boring and pits and variations in the subsurface conditions
may not become evident until excavation is performed. If conditions encountered
during construction appear different from those described in this report, we should be
notified at once so re-evaluation of the recommendations may be made.
This report has been prepared for the exclusive use by our client for preliminary design
purposes. We are not responsible for technical interpretations by others of our
information. As the project evolves, we should provide continued consultation and field
services during construction to review and monitor the implementation of our
recommendations, and to verify that the recommendations have been appropriately
interpreted. Significant design changes may require additional analysis or modifications
to the recommendations presented herein. We recommend on-site observation of
excavations and foundation bearing strata and testing of structural fill by a
representative of the geotechnical engineer.
If you have any questions or if we may be of further assistance, please let us know.
Sincerely,
H^EPWORTH - PAWLAK GEOTECHNICAL, INC.
Trevor L. Knell
Reviewed by:
Steven L. I'm
TLK/djb
attachments
Figure 1 - Location-Wrkploratory Boring and Pits
Figure 2 - Logs of Exploratory Boring and Pits
Figure 3 - Legend and Notes
Figures 4 and 5 - Swell -Consolidation Test Results
Figure 6 - Gradation Test Results
Table 1 - Summary of Laboratory Test Results
Table 2 - Percolation Test Results
Job !#103 469 C-095ba ch
0
rI
n TO SOPRIS
/ \ MOUNTAIN RANCH
/ \ \ ROAD
/ \
7820
BUILDING
ENVELOPE
/ T y
7820
�i \ LOT 30
//% �
amoP f/, 7830
PROPOSED
00
LEACH
FIELD // /
7830 / \ Q / // / 7840
\\ / P2 P3
\\ P 1
7840 PROFILE
\ PIT ■
7850
7850
I BORING 1 /PIT 2)
I
le /� /
I / �,0000AXREA OF PROPOSED /
I
PIT 1 RESIDENCE /
I � ■ /
7860
I / / APPROXIMATE SCALE
/
7870 1"=80'
I � /
—7(-
7860 7870
103 469 I GEO ECHNICAL,WINC_ I LOCATION OF EXPLORSTORY BORING AND I Figure 1
BORING 1 PIT 1 PIT 2 PROFILE PIT
ELEV.=7854' ELEV.=7858' ELEV.=7852' ELEV.=7846'
7860
7855
7840
7835
ao
20/12
7855
WC=9.7
•.A
DD= 119
7850
-'T
1
T •..
50/7
0
0
0
7845
w
7840
7835
ao
7855
•.A
:d.
T•6,
6'
WC=14.9
7850
DD=110
m
8'
+4=77
-200-8
0
LL=32
--
P1=17
7845 7845
a'
w
a,
t•Q
7840
NOTE: Explanation of symbols is shown on Figure 3.
7835
103 469 HEPWORTH—PAWLAK LOG OF EXPLORATORY BORING AND PITS Figure 2
GEOTECHNICAL, INC.
9
LEGEND:
® TOPSOIL; sandy clay, organic, dark brown.
CLAY (CL); slightly sandy to sandy, scattered rock fragments up to cobble size, stiff to very stiff,
slightly moist, dark brown, blocky.
GRAVEL AND COBBLES (GC); sandy clay matrix, with boulders, dense, slightly moist, brown, medium
plastic fines, subangular rock.
bRelatively undisturbed drive sample; 2—inch I.D. California liner sample.
Drive sample; standard penetration test (SPT), 1 3/8 inch I.D. split spoon sample, ASTM D-1586.
1/12 Drive sample blow count; indicates that 20 blows of a 140 pound hammer falling 30 inches were
required to drive the California or SPT sampler 12 inches.
Hand driven liner sample.
Disturbed bulk sample.
TPractical rig refusal. Where shown above bottom of log, indicates multiple attempts were made
to advance the boring.
NOTES:
1. Exploratory boring was drilled on July 21, 2003 with a 4—inch diameter continuous flight power auger.
Exploratory pits were excavated on July 23, 2003 with a Komatsu PC60 trackhoe.
2. Locations of exploratory boring and pits were measured approximately by pacing from the features
shown on the site plan provided.
3. Elevations of exploratory boring and pits were obtained by interpolation between contours shown on the
site plan provided.
4. The exploratory boring and pit locations and elevations should be considered accurate only to the
degree implied by the method used.
5. The lines between materials shown on the exploratory logs represent the approximate boundaries
between material types and transitions may be gradual.
6. No free water was encountered in the boring or pits at the time of drilling or excavation.
Fluctuations in water level may occur with time.
7. Laboratory Testing Results:
WC = Water Content ( % )
DD = Dry Density ( pcf )
+4 = Percent retained on No. 4 sieve.
—200 = Percent passing No. 200 sieve.
LL = Liquid Limit ( % )
PI = Plasticity Index ( % )
1103 469 I HEPWORTH—PAWLAK I LEGEND AND NOTES I Figure 3 I
GEOTECHNICAL, INC.
•
Moisture Content = 9.7 percent
Dry Density = 119 Pcf
Sample of: Sandy Clay
From: Boring 1 at 2 Feet
9
8
7
6
b\
c 5
°
Expansion
m
o
upon
o 4
wetting
LJ
I
o 3
m
m
m
a
0 2
U
1
0
1
2
0.1 1.0 10 100
APPLIED PRESSURE — ksf
103 469
HEPWORTH—PAWLAK
GEOTECHNICAL, INC.
SWELL—CONSOLIDATION TESTRESULTS
Figure 4
9
•
Moisture Content = 14.9 percent
Dry Density = 110 pcf
Sample of: Sandy Clay
From: Pit 2 at 1.5 Feet
3
2
c
0
m 1
a
n
w
0
Expansion
upon
wetting
C
O
m
0 1
a
E
0
U 2
3
0.1 1.0 10 100
APPLIED PRESSURE - ksf
103 469
HEPWORTH—PAWLAK
GEOTECHNICAL, INC.
I SWELL—CONSOLIDATION TEST RESULTS
Figure 5
HEPWORTH-PAWLAK GEOTECHNICAL, INC.
TABLE 1 JOB NO. 103 469
SUMMARY OF LABORATORY TEST RESULTS
•
•
NAl'NWI.
MOISTURP:
CONTENT
00
NATLIWL
DRY
DENSI'r)
(Pd)
GIUDA'I'ION
PERCENT'
PASSING
NO. 3N
SIEVE
A'11'ERRERGLPIITS
UNCONFINED
COMPRESSIVE
STRENGTII
IPSP)
SOIL MT.
S.UII'LP:
LOCA! '10N
DEM11
(het)
GRAVEL
IR)
SAND
(81
LIQ171)
LPIIl'
19E)
PLASTIC
INDEX
(901
Boring 1
2
9.7
119
sandy clay
Pit 2
1'L
14.9
110
sandy clay
5 to 6
77
15
S
32
17
slightly clayey sandy gravel
and cobbles
•
•
C,
J
HEPWORTH-PAWLAK GEOTECHNICAL, INC.
TABLE 2
PERCOLATION TEST RESULTS JOB NO. 103 469
HOLE NO.
HOLE DEPTH
LENGTH OF
WATER DEPTH
WATER
DROP IN
AVERAGE
(INCHES)
INTERVAL
AT START OF
DEPTH AT
WATER
PERCOLATION
(MIN)
INTERVAL
END OF
LEVEL
RATE
(INCHES)
INTERVAL
(INCHES)
(MIN./INCH)
(INCHES)
9
9
0
P-1
54
30
9
83/4
114
83/4
83/4
0
240
8 3/4
8 1/2
1/4
10 1/4
10
1/4
P-2
49
30
10
10
0
10
9314
1/4
240
93/4
93/4
0
9 1/4
9
114
P-3
48
30
9
83/4
1/4
8314
8 1/2
114
120
8 1/2
8 1/4
1/4
Note: Percolation test holes were hand dug in the bottom of backhoe pits and soaked on July
24, 2003. Percolation tests were conducted on July 25, 2003. The average percolation
rates were based on the last two readings of each test.
970-927-3801
F
p.I
WELL CONSTRUCTION W TEST REPORT OFFICE USE OM.Y
STATE
OF COLORADO, OFFICE OF THE STATE ENGINEER
I-
WELL PERMIT NUMBER 253838
2.
Owner Name(s): Robert Mandich
Mailing Address_ 100 Dean St. #3F
City, Stale, Zip: Aspen, Co. 81611
Phone # : 970-925-8029
WELL nrw APPROVAL # GWS31-91-03
3
TION AR ORII r Fri
DISTANCES FROM SEC. LINES NW 1/4 NE 1/4 Sec: 33 Twp: 8 S Range: 87 W
1320 R from North Sec. line and 2345 R tram East Sec. line OR Northing- Esstin _
8
SUBDIVISION: Sopris Mountain Ranch LOT: 30 BLOCK PILING (UNrI'):
STREET ADDRESS AT LOCATION
4
GROUND SURFACE ELEVATION R DRILLING METHOD Air Rotary
DATE COMPLETED: 429/2004 TOTAL DEPTH: 600 DEPTH COMPLETION: 822
5. GEOLOGIC LOC 6. HOLE DIANWTER (in) FROM (a) TO (a)
T ai'Material Si Color. and 9.0 0
48
8
000 to 030 Boulders, CI 6.5
48 6
030 to 600 Manors Shile
7. PLAIN CASING
OD (m) Rad Wall se Fn (a) To (a)
7.0 Steel 0240 -1 4F-
55 PVC 0.250 40 280
5.5 PVC 0.250 320 600
PERF. CASING : Screen Slot Size
5.5 PVC 0250 280 320
8. Filter Pack 9. Packer Placement
Water Located: 280 - 300
Material Type ;
Size : Depth
Remarks Interval
10. GROUTING RECORD
htdand Aao®1 Dmstr ItQaral
Plaralet
Cement 5 sks 6 aUsk 10-40
IL DISINFECTION Type HTH Amt. Used: 23 oz -
12. WELL TEST DATA : () Check Box If Test Data Is Submined On Supplemental
TESTING METHOD: Air Compressor
Static Level : 32 fl. Datefrime Measured 4/29/2004 Production Rate 3 Wo
Pumping Level: Total ft. Datelrime Measured 4/29/2004 Test Length : 2 bars
Test Remarks :
13. 1 lase rod de. �aV 1por se arab amr, addr ibj a<oa b ey ta.
ue9ie+el pntr bae se�aAc WnpmY ..".? ii meaac) �6-(P�troSasa lei-1./(Dx�)OtS-14 uiuf Wfilse mtevnr
CONTRACTOR : Shelton Drilling Corp. Phone: (970) 927-4182
Mailing Address : P.O. Box 1059 Basalt, Co. 81621 Lic. No. 1095
Name / Title (Please Type or print)
Signature
Date
Wayne Shelton / President
5/10/2004
Form„`No. OFFICE OFTHEIZTATE ENGINEER
-8WS-25 COLORADO DIION OF WATER RESOURC*
818 Centennial Bldg., 1313 Sh rman St., Denver, Colorado 80203
(303) 866-3581
APPLICANT
ROBERT MANDICH
100 DEAN ST #3F
ASPEN, CO 81611 -
(970)925-8029
1095
WELL PERMIT NUMBER 253838 _
DIV. 5 WD 38 DES. BASIN MD
J
.,.,, ,.,,, mvuN Ir IN "Ncr1
APPROVED WELL LOCATION
PITKIN COUNTY
NW 1/4 NE 1/4 Section 33
Township 8 S Range 87 W Sixth P.M.
DISTANCES FROM SECTION LINES
Ft. from Section Line
Ft. from Section Line
UTM COORDINATES
Northing: Easting:
ISSUANCE OF THIS PERMIT DOES NOT CONFER A WATER RIGHT
CONDITIONS OF APPROVAL
1) This well shall be used in such a way as to cause no material injury to existing water rights. The issuance of this permit
does not assure the applicant that no injury will occur to another vested water right or preclude another owner of a vested
water right from seeking relief in a civil court action.
2) The construction of this well shall be in compliance with the Water Well Construction Rules 2 CCR 402-2, unless approval
of a variance has been granted by the State Board of Examiners of Water Well Construction and Pump Installation
Contractors in accordance with Rule 18.
3) Approved pursuant to CRS 37-92-602(3)(b)(II)(A) as the only well on a tract of land of 35.03 acres described as lot 30,
Sopris Mountain Ranch division of land, Pitkin County.
4) The use of ground water from this well is limited to fire protection, ordinary household purposes inside not more than
three (3) single family dwellings, the irrigation of not more than one (1) acre of home gardens and lawns, and the watering
of domestic animals.
5) The maximum pumping rate of this well shall not exceed 15 GPM.
6) The return flow from the use of this well must be through an individual waste water disposal system of the
non -evaporative type where the water is returned to the same stream system in which the well is located.
7) Pursuant to Rule 6.2.3 of the Water Well Construction Rules, the well construction contractor shall submit the as -built well
location on work reports required by Rule 17.3 within 60 days of completion of the well. The measured location must be
accurate to 200 feet of the actual location. The location information must include either the 1/4, 1/4, Section, Township,
Range, and distances from section lines, or a GPS location pursuant to the Division of Water Resources' guidelines.
NOTICE: This permit has been approved for a well located pursuant to Rule 6.2.3. The location provided by the applicant
did not place the proposed well on applicants property. Proposed well must be located in NW 1/4, NE 1/4, Section 33. You
are hereby notified that you have the right to appeal the issuance of this permit, by filing a written request with this office
within sixty (60) days of the date of issuance, pursuant to the State Administrative Procedures Act. (See Section 24-4-104
through 106, C.R.S.)
NOTE: Parcel Identification Number (PIN): 49-2465-331-01-005
NOTE: Assessor Tax Schedule Number: R006966
(fit_ /a/283
APPROVED
MBC L� -
Aineer
Receipt No. 9501682 [
Vicki Monge, 02:08 PM 8/2/2004, Rot 30 Sopris Mt Ranch - Robert Manlo
X -Sender: vickim@sam
X -Mailer: QUALCOMM Windows Eudora Pro Version 4.2.0.58
Date: Mon, 02 Aug 2004 14:08:41 -0600
To: Nancy MacKenzie <nancym@ci.aspen.co.us>, jima@ci.aspen.co.us,
vickim@ci.aspen.co.us, tonyf@ci.aspen.co.us, nancyb@ci.aspen.co.us,
stephd@ci.aspen.co.us
From: Vicki Monge <vickim@ci.aspen.co.us>
Subject: Re: Lot 30 Sopris Mt Ranch - Robert Mandich
X-MailScanner-Information: Please contact the ISP for more information
X-MailScanner: Found to be clean
Address is 805 Sopris Mountain Ranch Road. Permit number #0482.2004.prrb.
Vicki
A 01:21 PM 8/2/2004, Nancy MacKenzie wrote:
I am ready to issue the septic permit for this residence, so it is okay to issue the Building Permit.
(Do you have a street address for this property?)
Thanks- Nancy
Nancy MacKenzie
Pitkin County Environmental Health
Senior Environmental Health Specialist
0405 Castle Ck Rd, Suite 10
Aspen, CO 81611
970-920-5076
970-920-5077 fax
nancym@ci.aspen.co.us
�v
Printed for Nancy MacKenzie <nancym@co.pitkin.co.us>
Page 1 of I
8/2/2004
To: Rick Magill, Community Development' Dept.
From: Mary Engelmann,'Environmental Health Officer '
Through: Lee Cassin, Assistant Environmental Health Director X'K.
Date: November 29,1996
Re`. Heller/Moss 1041 Hazard Review & Lot Line Adjustment.
Parcel ID # 2465,331-01-005
The Aspen/Pitkin Environmental Health Department has reviewed the details of the
Heller/Moss application under the -authority of the Pitkin County Code, Title II,- Land Use
Code and has the following comments.
ADEQUATE PROVISIONS FOR WATER NEEDS: Sections 2-170 and 3=110.4::
'It Is the policy of the county to Insure the availability of awater supply of adequate quality, quantity, pressure and dependability for fire protection
and support of a proposed land use prior to approval of the use. The County shall require land uses'to hook up to existing public rsystems ,If service is
available.•.. - This Department needs adequate information on the quantity/quallty of water available.
This can be done from. tests of wells present on-site by a water engineer's or well
driller's report. The applicant.must ensure that the water quality Is acceptable by having
it tested by'a lab .such as the Snowmass water and Sanitation District,or Aspen
Consolidated Sanitation District. water of acceptable quantity has been obtained in
other lots In this area. Before a septic permit can .be issued, the well must be drilled to
assure that setback requirements from the well to. the sewage disposal system can tie
maintained. Pitkin County Land use Code requires that the weir site be within the
.building envelope..
It is, recommended that low water landscaping (xeriscaping) be used and that,the timing
of.any sprinkler systems be decreased for low water. plants. The Colorado State
University cooperative Extension office can be contacted for more Information on
xe.riscaping.
t
A condition of approval for -this application is the receipt of information
documenting that the locations of the wells meet setback requirements
and can be placed within 'the building envelopes and that quantity/quality .
of the well water are adequate. 'Without meeting these requirements;
sewage disposalsYstem permits and building permits. can not be issued.
1
0
■
SEWAGE TREATMENT AND COLLECTION: Sections 2-180 and 3-110.5:
'Itis the policy of the County to ensure that adequate sewage treatment fwiitles are available to serve existing and new developments. Public and.
private Sewage disposal systems and connections to Such systems Shall comply wlth the sewage disposal guidelines of Pitkin County's Individual Sewage
Disposal System Regulation'
Lots in the SopriS Mountain Ranch area are served by individual -sewage disposal
systems: All such systems installed within Pitkin County require septic permits issued by
the Environmental Health Department, and must comply with the County's sewage
disposal regulations. To receive a septic permit, the applicant will need to submit a.
septic permit application and appropriate fee with.a completed soil data information
including percolation test results•and profile hole information as'weli as site piamand
building floor plans... it must be, possible to design an adequate sewage disposal system
before a, building perniit.can -be issued.'
The Aspen/Pitkin Environmental. Health Department will design the system for
the applicant as part of the permit fee, .if an engineered system is not required...-
We
equired.•.We will do a site visit, advise the applicant about the best location for the system and
provide a system design. We will determine if an engineered system is.needed based on
soiltest results. -An engineered system is required if any one.of the following
conditions exists: a percolation rate faster than 5 mpi or slower than 60 mpi; maximum
seasonal level of the he table or bedrock less than four feet below the
bottom of the proposed absorption system; or a slope in excess of 30%.. Prior to
initiating any tests at the site, the applicant should Contact this office.
'No percolation test resUlts.were provided, so it is unknown at..this time what types of.
systems will be required. it is likely, that sewage disposal systems can be installedon
these lots, however, the applicants should be aware that there are some lots in the
Sopris Mountain Ranch area.that have had to- have engineered systems installed. Site
specific soil data will have to be obtained, and the applicants will need to adhere to. -
minimum horizontal setback requirements for placement of sewage disposal system
components. A setback chart has been Included with these comments. They -will need .
to: locate the leach field sites.a minimum of 100 feetfrom their wells and from any-.
neighboring wells. 'Depending on the size of the homes and the number of -bedrooms _.
or rooms of similar size, there is the possibility that the .distances will have to be greater
than 100 feet between wells.and sewage disposal systems. For. example,.a home :of.
between 2,000 4 6,000 sq. ft. with 5.bedrooms or rooms of similar size will need to:be.at
least 156 feet from any wells, The proposed building envelopes are large so there
shouldn't.be a problem maintaining the required distances from _the.well and sewage
disposal system components. Placement of the wells should be considered prior to
drilling to insure that there will be no problems with maintaining these setbacks. 1
It is desirable to locate the system downhill from the house so that the systerp can
operate by gravity:.. The leaching area itself should-be.on an area that is as level as
possible. According to the information provided, the. building envelopes range...'
M
between 10 to 25% slopes. Since no soil absorption system shall be permitted in areas
where the ground slope is in excess of 30% unless designed by an engineer, this
Department may need sufficient information to document that the area for the sewage
disposal systems) is not in excess of 30%. If the sewage disposal systems) is installed in
separate trenches terraced down the slope, the system(s) should function properly.
According to the information provided in the application, the lot line adjustment has
created a new building envelope where the slopes are less.severe. From the standpoint
of this Department, that has allowed for a more suitable location for a sewage disposal
system to be installed.
The area for the leach fields should be located in an area of no traffic, planted with dry
land grass, and should not be watered. The applicants should refer to the Pitkin County
Sewage Regulations for detailed information, or call our office to discuss this site.
If the well permit states that the sewage disposal system must be of the non-
evaporative type where the water is returned to the same stream system in which the
well is located, a completely lined field, such as an evapo-transpiration bed, is not
allowed unless the applicant contacts the Colorado Division of water Resources and a
new well permit is in place or a plan of augmentation is created.
A condition of approval for this application is the receipt and approval of
the sewage disposal permits by the Environmental Health Department
before building permits can be issued. The sewage disposal systems must
be located within the building envelopes.
WATER QUALITY IMPACTS: Sections 2-140 and 3-70.5 and 3-70.10:
-It is the policy of the County to preserve and protect its present water resources, recognizing the County's semi -arid character and that significant
transmountain and transbasin diversions and the vested rights of senior appropriators in the basin have materially curtailed the availability of an
already scarce water resource. To this end it is the policy of the County that no land use be initiated which would adversely affect the quantity, quality.
or accessibility of the County's water resources; or which would occur at the expense of established water -dependent agricultural activities; or which
would result In increased saIinization of water resources, loss of minimum stream flows, further destruction of wildlife habitat, or major expenditures
to reacquire or redistribute major water resources. It is also the policy of the County to maintain a natural vegetative buffer along its surface waters
such that the surface and groundwaters of the area are not encroached upon by land uses or other human activities which could cause deterioration of
water quality or impair the natural treatment processes provided by meadows and wetlands.' .
The Environmental Health Department is charged with preserving and protecting the
quality of Pitkin County's water resources. Since a large percentage of the population is
dependent upon water from wells, elimination of groundwater pollution, and
protection of aquifers and their drainage areas are of utmost importance.
Surface water and groundwater contamination can also be caused by inadequate
setback distances from sewage disposal systems to proximate wells, rivers, creeks,
ponds, ditches and reservoirs. Minimum horizontal distances between components of a
sewage disposal system and physical features must be in accordance with the Pitkin
County Sewage Regulation. This Department reserves the right to require water quality
sampling at the homeowner's expense.
123
A condition of approval for this application is that all setback distances be
maintained between sewage disposal system components and wells, rivers,
creeks, ponds, ditches and reservoirs.
AIR QUALITY: sections 2-130 and 3-602:
'Only that development is permitted which will not contribute significantly to degradation of air quality.
This project is not expected to contribute significantly to degradation of air quality in
Pitkin County.
Activities such as road building and landscaping require a Fugitive Dust Plan. This plan
would need to include, but is not limited to, fencing, watering of haul roads and
disturbed areas, daily cleaning of adjacent paved roads to remove mud that has.been
carried out, speed limits, or other measures necessary to prevent windblown dust from
crossing the property line or causing a nuisance,
A condition should be approval by the Aspen/Pitkin Environmental Health
Department of the fugitive dust control plan, containing enough measures
to ensure that dust does not become a nuisance or blow onto adjacent
property.
The applicant must file a fireplace/woodstove permit with the Environmental Health
Department before the building permit will be issued.
The less densely populated parts of the county like Sopris Mountain Ranch may have
two devices per building: a maximum of one wood burning fireplace and a second
device which can be either a gas log fireplace or a certified.woodstove. In addition,
unlimited numbers of decorative gas appliances are allowed. Coal may not be burned in
any device. No wood burning device maybe installed in barns or agricultural buildings.
A condition of approval for this application is the receipt and approval of
the fireplace/woodstove permits by the Environmental Health Department
before the building permits can be issued.
CONFORMANCE WITH OTHER ENVIRONMENTAL HEALTH LAWS: section 2-70:
"It is [Me policy of the County to ensure that no use or development of land is peryitted which is In violation of the laws of the County, the State of
Colorado. or the United States of America.-
This Department is not aware of any Issues lof concern regarding other environmental
health laws.
3Li
DRAWN 8 DESIGNED BY.
N.E.B.
CHECKED BY.
H.E.B.
REVIEWED BY.-
DATE.
FEET 20 0 20 FEET
GRAPHIC SCALE
I inch 20 ft.
CONTOUR INTERVAL = 2 FEET
ri7;J
NO TE:
1. SEE SECTIONS, DETAILS AND GENERAL NOTES
ON SHEET 2 OF 2.
CONSUL TING ENGINEERS • 0805 BUCK PRINT ROAD
CARBONDALE, CO 81623 • (970) 963-2170
REVISION DATE I DESCRIPTION
1 7-8-05 REVISED SEPlC SYSTEM DESIGN BASED ON NEW
PERCC, RATES
RECEIVED
8 2005
"'LINTY
ENViR(; tl441:N ML HEI i
BY 22 ROBERT MANDICH ASPEN, COLORADO SCALE JOB N0: DATE
N.E.B. H.E.B. l" = 20' 2004.0/0 8-8-05
SHEET NO:
LOT 30 SOPRIS MOUNTAIN RANCH - O WS PLAN / OF 2
FAVAL'l W012-I14:ils
1. HOUSE SIZE — 4 BEDROOMS, <6000 SF
2. LOADING — 100 GAL/PERSON/DAY
3. A VERA GE LOADING — 800 GPD
4. PERCOLA TION TEST RESUL TS.•
P T-1 = 30 MPI
PT -2 = 15 MPI
PT -3 = 21 MPI
A VERA GE PERCOLA TION TEST RA TE = (30f 15+21)/3
PERCOLA TION RA TE = 22 MPI
5. PEAK HYDRAULIC LOADING RATE (Q) = 1.75 X 800 = 1400 GPD
6. REQUIRED PERCOLA TION AREA = (Q X (50)'� 5)/5
(14 00 X (50) ^ 5)15 = 1313 SF
7. ZERO REDUCTION IN ABSORBTION FIELD AREA TAKEN
GRA VELLESS CHAMBER BED SPECIFICA TIONS.
1. TOTAL AREA INFIL TRA TION AREA REQUIRED = 1313 SF
2. EACH CHAMBER AREA = 2.5 FT X 6.25 FT = 15.625 SF
J. TOTAL NUMBER OF CHAMBERS = 1,311 SF / 15.625 SF = 84
4. USE 2 CHAMBER BEDS EACH WITH 48 CHAMBERS — 96 TOTAL CHAMBERS
5. TOTAL ABSORPTION AREA OF CHAMBER BEDS = 96 X 15.625 = 1500 SF
6. GROSS WIDTH OF EACH BED = 18 FT (3 FT PER CHAMBER)
7. GROSS LENGTH OF EACH BED = 50 FT (6.25 FT PER CHAMBER)
SEPTIC TANK TREA TMENT SPECIFICA TIONS -
1. TOTAL MINIMUM CAPACITY = Q X (30 HRS/24 HOURS) _
= 140OX (30 HRS/24 HOURS)
= 1750 GAL.
USE (2) 1000—GALLON SEPTIC TANKS (SEE TANK DETAIL ON THIS SHEET)
FINISHED GRADE
NATJVE BACKFILL
/ 4" ASTM 3034 — SDR 35
OBS ERVA110NIIIENT PIPE
WITH CAP (TYP)
DRAWN & DESIGNED 9)"
H. E. B.
CHECKED 9)-
H. E. B.
25'
3"
3'
SLOPE FOR ORq/VAGE
3'
3'
T
0
0
Qd
GRA VELLESS CHAMBER (TYP.)
— SDR 35
LINES
aPS ON
'PI CA L PLAN VIEW - GRA VEL
GRAVELLESS CHAMBER (TYP.)
Y X 6.25'
CHA MBER
INLET —�
OUTLET
PLAN VIEW
D 3034 — SDR 35
'TRIBUT/ON BOX
ADE MIN.
MANIFOLD
INSTALLED LEVEL
BED
FIBERGLASS LID WITH
fINAL GRADE �� 30" STAINLESS STEEL BOLTS
AND URETHANE GASKET
RIBBED PVC BASIN
4' PVC PIPE, EFFZUENT DISCHARGE
ADJACENT FIELD FROM P sEPnc
TANK
TYPICAL CROSS SECTION - GRA VEL L ESS CHAMBER BED
N. TS.
GENERAL NOTES
1. ALL MATERIALS, INSTALLATION PRACTICES, SETBACK REQUIREMENTS, E.TC,
SHALL COMPLY WITH THE PITKIN COUNTY INDIVIDUAL SEWAGE DISPOSAL
SYSTEM REGULA TIONS
2. PROVIDE ADEQUA TE SURFACE & SUBSURFACE WA TER DIVERSION TO ASSURE
THAT RUN—OFF DOES NOT ENTER THE ABSORPTION BED AREA.
J. ALL SEWER LINES AND SEPTIC TANKS SHOULD BE INSTALLED SO THA T THEY ARE
WA7ER TIGHT WHERE REQUIRED AND FROST PROOF.
4. THE ENGINEER AND THE PITKIN COUNTY HEAL TTI' DEPARTMENT SHALL BE N077FIED
48 HOURS PRIOR TO CONS TRUC77ON IN ORDER TO MAKE THE NECESSARY ACCOMMODATIONS
FOR INSPECTION OF THE DRAIN FIELD, SEWER LINES, AND SEP77C TANKS.
5. ALL PVC GRAVITY SEWER PIPE SHALL BE SDR 3.5 (ASTM D 3034) UNLESS 07HERWlSE NO7FD.
REVIEWED BY.
DATE
FOR
CONSUL TING ENGINEERS i 0805 BUCK PL7INT ROAD
CARBONDALE, CO 81623 • (970) 963-2170
INLET TEE
EFFLUENT FROM 4'" PVC
SEWER SERVICE 9 —29
MIN.
ELENA AON 4' PVC DISCHARGE
PIPE
30" FLOW SPLITTER BASIN
N. T.S.
FIBERGLASS GASKETED LID WITH
STAINLESS STEEL BOL IS —
OR SEALED CONCRETE LIDS 1
LIQUID LEVEL
SLOPE GROUND
AWAY FROM RISER
TANK NO. I
PVC RISER WITH GROMMETS
(BOND TO TANK ADAPTER WITH
RECOMMENDED ADHESIVE)
OR CONCRETE RISER WITH
RUBBER—NEK
TANK ADAPTER
(CAST OR BOL TED)
/INLET TEE
EFFLUENT FROM 1000 GAL. TANK ® —29 MIN.
OUTLET TEE
FLOW TO
BEO.S
N.T.S
CLEAN-OUT DETAIL
N. T.S.
LIQUID LEVEL ALARM
1. LIQUID LEVEL ALARM SHALL BE AN ORENCO
AMSENTI OR APPROVED EQUAL
POWER SOURCE 115 VAC
ENCLOSURE 4'X4 "XJ
SNCL OSURE RATING NEMA I
TEST SWI TCH SPD T
U010 ALARM 85 dB AT 12"
AUDIO SILENCE FEATURE SWI TCH
VISUAL ALARM RED LED
USE INDOOR ONLY
FIBERGLASS GASKETED LID WITH
STAINLESS STEEL BOL IS �}
OR SEALED CONCRETE LIDS
SLOPE GROUND
A WA Y FROM RISER
CONDUIT TO _.—
ALARM PANEL
CONDUIT SEAL
LIQUID LEVEL
2"
TANK NO.
HIGH LEVEL _
ALARM FLOAT
1 000 GAL. SINGLE COMPARTMENT SEPTIC TANK IN SERIES WITH
1 000 GAL COMPARTMEN T SEP TIC TANK EFFL DENT FIL TER
N T. S
FzOw
FROM
HOUSE
PVC SPLICE BOX WITH CORD GRIPS
PVC RISER WITH GROMMETS
(BOND TO TANK ADAPTER WITH
— RECOMMENDED ADHESIVE)
OR CONCRETE RISER WITH
RUBBER—NEK
FILTER CARTRIDGE HANDLE
(FIELD CUT TO DESIRED HEIGHT)
TANK ADAPTER (CASTOR BOLTED)
VENT ORIFICE
EFFLUENT DISCHARGE 0 —27. GRADE
MODULATING DISCHARGE ORIFICES
VA UL T INLET PORTS
— FIL TER CARTRIDGE
ORENCO FT0400 SERIES
4" BIO TUBE EFFLUENT FIL TER
REVISION DATE XSCRIPRON BY CHD ROBERT MAND/CH ASPEN, COLORADO SCALE• ✓08 NO: DATE.
1 7-8-05 REVISED SEPTY' SYSTEM DESIGN BASED ON NEW H.E.B. H.E.B. N. TS. 2004.1/ 7-08-05
PERC. RATES SHEET NO:
L 0 T 30 SOPRIS MOUNTAIN RANCH - OWS 2 OF 2
SECTIONS, DETAILS, AND GENERAL NOTES