Permit # 00013
Type of permit New( x) Repair( ) Addition to House( )
Name of Owner Doreen Goldyn
Street Address 710 N Bill Creek Rd
Property legal description SW1/4 SE1/4 Sec 27 T85 R88W
Size of lot 40 acres Total square footage of the house
Aspen/Pitkin Environmental Health Department
Permit for an Individual Sewage Disposal System
130 S. Galena St. Aspen, Colorado 81611
Phone 970-920-5070 / FAX 970-920-5074
Parcel ID # 2463-274-00-011
Water source Private well
# of bedrooms in house
Caretaker unit detached
# of bedrooms in caretaker unit
Designed for what '# rooms (list)
# of offices, lofts & similar sized rooms in house
Total square footage of the caretaker unit 750 square feet
1 # of offices, lofts & similar sized rooms in caretaker unit
2
Permit information
Designed by Church and Associates
Mailing Address 4501 Wadsworth Blvd., Wheat Ridge, CO 80033
Perc rate 14 Profile hole depth 8 ft Depth to groundwater or bedrock
Septic tank capacity 1250 gallon Absorption area 279 square feet
Comments
Unknown
L
Septic permit approved per compliance with the engineer design and specifications dated January 13, 2000. Any
changes must be approved by this department and the design engineer prior to them being made.
Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin
County ISDS regulations. This department does not endorse any brand of products.
The engineer must do a final inspection of the installation and submit an as -built letter to this department. This
department must also be called for an inspection with a minimum of 48 hours advanced notice.
System design calls for a 1250 gallon two compartment tank with a pump in the biotube vault in the second
compartment. Distribution box must have a baffle. Two lines running into two trenches, each having 1 row of 9
chambers. Trenches must have a minimum of 6 feet of undisturbed soil between them. A setback of at least 50
feet to the irrigation ditch must be maintained from the absorption field. The area where the absorption field is
installed should not be used as a horse corral. This area should remain free of traffic of any kind.
10111101
Permit approved b /C�m 1 lT( �i� Date: �_�> 31 I s
n and specifications of the proposed individual sewage disposal system have been revieJ�hnfteedohsiWred
Plans p p p 9
satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin
County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was
issued unless system construction has commenced or an extension has been approved in writing by the Department.
As -built drawings must Lbe included with this permit before the final approval will be issued.
Installer: ��ll I IR 6,V iVI 0lit 11 9 '% i �q 000001 �� ��•/
Date:
Final inspection approval: �'3 '7
3.
E
TUE 11:57 AM ASPEN/PITKIN ENV HEALTH FAX:970 920 5074f PACE 3
ASPEfN►.. SKIN ENVIRONMENTAL HEALTH DEPA , ,AENT
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM
130 S. Galena St., Aspen Colorado 81611
Phone 970-920-5070/Fax 970-920-5074
-k - nn
Name of OWNER _Dore, e. v\ Cr o I d y yn
Owner's Mailing Address f3 a X ) 1 a ) IB n A, w, } C- O 1
8s-.ne5s 03 1 Home Phone: 511p 9 -
Primary Contact Person (all communication regarding this permit will go through this person)
-dame d
Comoany o r -y
Cortaet Mailing Address (3 1 C.- 0 ) (o
Business Phone : Cell Phone: Fax: — 3
Parcec ID # (available from assessor's office
at 920-5160 or at www.aspon.com/assessort)
Street address of property
-1 q -4,3--�L1Z.�(-- o d -a-.)
sw� 5
Legal Description: Lot Block Filing H
Sec DM T85
Size of lot: 1- p acres. Type of proposed structure: F r ckyft Size of oldg. envelope: S
Total square feet of house_
x of offices. lofts & similar sized rooms in house
# of bedrooms in house N I f9
Caretaker Unit: Attached ( ) Detached( X ) Total area(sq. ft.) of caretaker unit 1� s 0
9 of `zpdrnnms in rnretaker unit f # of offices. lofts and similar size rooms of coretaker unit O
1
Permit is for: New Home ( X ) Repair due to failure ( ) Remodel/Addition ( ) Emergency use ( )
Water. Private well ()<) Spring ( ) Stream ( ) Community/Public Water System ( )
If community system: Name of system
r^e fee for a ISDS application is $330 for a permit that takes 6 hours or less for the department to approve. If approval -takes
longer than 6 hours, a rate of $55 per hour will be charged. The maximum fee is $1000. The basic fee of S330 is due at the time
of application. The remainder, if any, will be due in two stages: first, at the time of issuance of the ISDS permit: second, before
finai approval of the ISDS permit.
Application for an individual sewage disposal systf -, is hereby submitted. I hereby certify that the above information is true and
accurate and that I have provided true and accur 3 information on locations of all existing and proposed wells. contour
intervals, buildings, property lines, ditches, slopes, waterlines, springs, suction or irrigation lines, drinking water cisterns, drain
tiles, irrigation ditches, lakes, water courses, streams, floodplains, dry gulches. and existing septic systems. I hereby certify
teat any such features not shown on attached site map are not present. Issuance of the permit does not imply the approval of
any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all
approvals and permits have been obtained.
The Aspen/Pitkin Environmental Health Department. Pitkin County and employees of these agencies will be held harmless
should the Individual sewage disposal system fail or ction. The permit to construct is issued on information submitted by
the applicant or hislher representatives. The Dwn ssum s full responsibility in case of failure of the system.
Signature of applicant Date / 7 c) v
Received by Receipt # o l Date p C�
G:\ehkisds\isdsapp.doc
000002
CHURCH & Associates, Inc.
ENGINEERS & GEOLOGISTS
December 21, 2001
Todd Haberman
PO Box 1210
Basalt Colorado, 81621
GOI&AJ6
Subject: Installation Observation, Proposed Habemfw Residence
710 Bill Creek Road
Pitkin County, Colorado
Job No. 11948W
Mr. Haberman,
RECEIVE®
DEC 2 7 2001
PITKIN COUNTY
ENVIRONMENTAL HEALTH
As requested, we observed the installation of the onsite wastewater system (OWS) for the subject site on
December 12, 2001. The system was designed under our Job No. 11948W, dated April 25, 2000.
The system includes the installation of one 1250 -gallon, two-compartment, precast concrete septic tank
with a pump in a BiotubeTM pump vault in the second compartment. Two gravelless chamber trenches
were installed, each with one row of nine chambers, as indicated on Figure 1. A concrete distribution box
was used to distribute effluent to the beds. An as -built drawing is included as Figure 1.
The pump and BiotubO'm vault were in place at the time of our site visit. The OWS construction foreman,
Tony with Haberman Construction, may activate pumping system at his discretion. The components of
the OWS were installed in conformance with our plans and specifications.
If there are questions or if we may be of further service, please call.
Sincerely,
CH
Ed`
EOC/trp
2 copies sent
copy to APEHD, Attn: Madelyn
DENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 80033 CASTLE ROCK 303.660.4358
303.463.9317 Fax: 303.463.9321 EVERGREEN 303.816.1455
LOVELAND 970.663.2124
WESTERN SLOPE 970.948.5803
O
W O
U II
V)
co
ODM
c
co
i�0
tV Q
ZCC
<a0
cr W
W�
oCf)0
O
r Y
H
�cna
t°
a
U.W
Q z
z
ro
3w
0
.Ja
3IL
IL
O n.
z0
•
w �.
z
W
C>
Z_
0
CLt
w
cry o
W L L
>_jco <�z W
Q � LU o
Q �Z-fir J
Q U Q a a a w LU
JAZ= Z >� Z
F= W LIJ LU
Z � Z Ir OJ - Q
O!— LuwC)o dnLLI -i-LU w0z S
�-zU�� C?CL LUF0 >
cOQZz= ��nowZn
�LYEL'QU NY Z
(\j< WOE OU�o
Z�o�w
of-ucLo
LIJ
X CL
CL
Z U
0
CL
CO
cV
CL
j o
o zo�
Q / w O
/ -IL
U Q o
V)W
(DCL
zo
D J
J
m Z
w
Z
� Q
13K
J
w
L
0
z
co
O
000005
a
F' z
�U
U r'
m�
z
W O
0
LU
—
W
LL Of
w �.
z
W
C>
Z_
0
CLt
w
cry o
W L L
>_jco <�z W
Q � LU o
Q �Z-fir J
Q U Q a a a w LU
JAZ= Z >� Z
F= W LIJ LU
Z � Z Ir OJ - Q
O!— LuwC)o dnLLI -i-LU w0z S
�-zU�� C?CL LUF0 >
cOQZz= ��nowZn
�LYEL'QU NY Z
(\j< WOE OU�o
Z�o�w
of-ucLo
LIJ
X CL
CL
Z U
0
CL
CO
cV
CL
j o
o zo�
Q / w O
/ -IL
U Q o
V)W
(DCL
zo
D J
J
m Z
w
Z
� Q
13K
J
w
L
0
z
co
O
000005
Apr 25 00 02:28p CH'iRCH & Assocaties 303-463-9321 p•2
CHURCH & Associates,lnc.
ENGINEERS & GEOLOGISTS
April 25, 2000
Todd Haberman
PO Box 1210
Basalt, Colorado 81621
Subject: Clarification of Existing Corral, Proposed Haberman Residence
710 Bill Creek Road
Pitkin County, Colorado
Job No. 11948
Dear Mr. Haberman,
As requested, by the Aspen Pitkin Environmental Health Department (APEHD), we must clarify the use of
the existing corral, as indicated on Figure 1, of our original design, dated January 13, 2000.
It is our understanding livestock will not be confined in the existing corral. It is to be used as a drain field
with small native plants and grass beds.
If there are questions or if we can be of further service, please call.
Sincerely,
CHURCH & AssociatesI l p R$�
:r' a
Edward O. Church, P. '
EOC/trp
1 copies sent
fax copy to APEHD, Attn: Carla, 970-920-5074
000006
DENVER 4501 Wadsworth Boulevard Wheat Ridge, Co 80033 CASTLE ROCK 303.660,4358
303.463.9317 Fax: 303.463.9321 EVERGREEN 303.816.1455
ASPEN/PITKIN EIRRONMENTAL HEALTH DEPAPd-MENT
ISDS DESIGN CALCULATIONS
Owner's Name -,17A>#MAf y�� ORYN, Parcel ID # ,57,0'
'YiNSp.�f � YK
House Size (sq. (75 gpd, 100 gpd, or 130 gpd) 75
Number of Bedroo sin Main H V W,
Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House "kti� Ferri; Q
Number of Bedrooms in Detached Caretaker unit
Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit
(If the caretaker unit is ATTACHED, treat as if part of main house.)
Average Daily Waste Flow 300
State Review Required? no
Perc Rate 2 !,!5
Design Flow (Q) = # potential bedrooms X 2 people/bedroom X gpd X 1.75
Q= 525
Absorption Area (A= Q/5 X SQRT)
A = 393 sq. ft. of absorption area required
25 infiltrator units without reduction
A maArnuwn 30% reduction is allowed for use of deep gravel or gravelless chambered system,
only if the lot size and soil conditions are optimal.
If a reduction is being, proposed, describe why lot size and soil conditions are optimal:
GOOD SOIL CONDITIONS, DOSING TRENCHES
A = 275 sq.ft with reduction
18 infiltrator units with reduction
Type of system: []Absorption trenches GAbsorption bed [x] Gravelless chambers
[]Dry well []Seepage Pit flOther
Minimum tank capacity 656 gallons'
SETBACK FROM WELL
# of feet = 100
SETBACK FROM POND, STREAM OR IRRIGATION DITCH
# of feet = 50
SETBACK FROM DRY GULCH
# of feet = 25
FINAL INSPECTION BY:
000007
DATE:
Engineer's Submittal for Septic Permit in Pitkin County
Owner's Last Name: HABERMAN Location: 710 BILL CREEK ROAD
Summary of information regarding new septic system:
Type of system being proposed: SEPTIC TANK AND GRAVELLESS CHAMBERS
Other treatment processes being used: NONE
Does the system use any mechanical parts? (Prohibited unless there is no alternative)YES
If yes, explain why there are no alternatives A PUMP IS REQUIRED DUE TO ELEVATION
DIFFERENCE FROM SEPTIC TANKS TO DRAIN FIELD
Does the system require any maintenance other than routine pumping? YES
If yes, who will do the maintenance? CLEAN FILTER WHEN SEPTIC TANK IS PUMPED
Are any reductions being proposed? YES
If yes, what makes the lot and soil conditions optimal?
GOOD SOIL CONDITIONS AND DOSING TRENCHES
Which of the following are on the site or within setbacks?
Closest distance of septic system to each feature
100 year floodplain NLA
H well(s) >100 FEET
[] irrigation ditches >50 FEET
[] streams >50 FEET
[] ponds NLA
[] other features NLA
What was the profile hole depth? N/A
What is the depth to groundwater? N/A
What is the depth to bedrock? NLA
What assumptions, if any, were made in system sizing and design? (Include any local, site-
specific data, such as months without snow cover, ratio of evaporation to absorption, etc. that are
relevant.)
If there are any variations from normal design, please explain how they can be demonstrated to
improve treatment and protect water quality. NONE
000003
CHURCH & Associates, Inc.
ENGINEERS & GEOLOGISTS
January 13, 2000
Todd Haberman
PO Box 1210
Basalt, Colorado 81621
Subject: OWS Design, Proposed Haberman Residence
7'10 Bill Creek Road
Pitkin County, Colorado
Job No. 11948
Dear Mr. I laberman,
As requested, we have reviewed the subsurface conditions reported by HP Geotech for the subject site and
prepared an onsite wastewater system (OWS) design for the proposed residence. The subsurface
investigation was performed on October 18, 1999.
SITE CONDITIONS
The property is located in a rural residential area in Pitkin County where OWS are required. There are
several existing buildings located on the property with a two-bedroom residence proposed as indicated on
Figure 1. The Crystal River flows south to north along the western portion of the property and there is a
seasonal irrigation ditch flowing through the center part of the property from south to north. The proposed
drain field area is relatively flat, and has thin cover of native grasses. The proposed residence will be located
topographically lower than the drain field. There are two existing wells located 500+ feet from the
proposed drain field.
PROPOSED CONSTRUCTION
A two-bedroom residence with an area less than 2000 square feet (SF) is proposed as presented on Figure
1. We have sized the OWS based on 2 bedrooms and 300 Gallons Per Day (GPD) using Aspen/Pitkin
Environmental Health Department (APEHD) loading of 75 gallons per day per person. The design sewage
loading with a peaking factor of 1.75 is 525 GPD. This loading includes washing machines and garbage
grinders. The drain field is to be a minimum of 100 feet to all wells and 50 feet from the irrigation ditch.
SUBSURFACE CONDITIONS
HP Geotech performed a subsurface investigation by digging 3 percolation holes, 50 to 62 inches deep, and
one profile pit at the locations indicated on Figure 1. Subsurface conditions in Profile 1 consisted of 1.5 feet
of topsoil, underlain by silty sand to 4.5 feet, underlain to the maximum depth explored of 8 feet by silty
sandy gravel with scattered cobbles. Percolation tests indicate percolation rates of 12 to 17 minutes per inch
(MPI). The average percolation rate is 14 W1. Percolation data is presented in Appendix A.
RECOMMENDATIONS
We recommend the installation of a septic tank, a pump, and two chamber -type trenches installed at the
locations presented on Figure 1. The OWS design is based on a design sewage load of 525 GPD and a
percolation rate of 14 MPI. The installation requires one 1250 -gallon two-compartment precast concrete
DENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 80033 CASTLE ROCK 303.660.4358
303.463.9317 0
00009 Fax: 303.463.9321 EVERGREEN 303.816.1455
OWS Design
Job No. 11948
Page 2
septic tank with a pump in a Biotube vault in the second compartment, as indicated on Figure 3. Total flow
rate of 25 Gallons Per Minute (GPM) and a Total Dynamic Head of 46.5 feet is needed for the pump. Pump
details are present on Figure 4. We recommend the installation of two trenches, each with 1 row of 9
chambers with 4" PVC perforated pipe place on the surface of the ground. A distribution box is required to
distribute effluent to the fields.
Vehicle movement over the drain field area during construction should be kept at a minimum to
prevent compaction of the receiving soils. We recommend the bottom of the bed be scarified with a
pick, shovel, or backhoe bucket teeth prior to the addition of chambers.
The surface of the field should be seeded after installation using a native seed mix available at seed stores.
These mixes do not require irrigation and develop a growth 10 to 15 inches high. No automatic sprinkler
system should be installed over the field.
OPERATION AND MAINTENANCE
The owner must realize an OWS is different from public sewer service. The owner must be aware of
and assume responsibility for maintenance of the system. In the absence of a monitoring program, we
recommend the septic tank be pumped every two years. Effluent filter and screened vaults, as
applicable, are to be cleaned during pumping. There are daily considerations such as not putting plastic
or other nonbiodegradable materials into the septic system. Garbage disposal use should be minimized.
The backwash of a water softener may be harmful to the OWS. A separate drywell should be constructed
for the backwash waste, if a softener is installed. Chemically treated water from a swimming pool or spas
should not be introduced to the OWS.
LIMITATIONS
An OWS design should be installed by a contractor who is experienced in its installation. Our investigation,
layout, design and recommendations are based on data submitted. If subsurface conditions considerably
different from those described in this report are encountered, we should be notified to evaluate the effect on
the proposed OWS. If the health department makes modifications to this design, we should be contacted to
evaluate the impact on the performance of the OWS. The county and our firm must be contacted upon
completion of the OWS
All construction is to be in accordance with the ISDS regulations. Pipe type and size, burial requirements,
septic tank construction, and other specifications, which are not depicted in our report, are to conform to
the requirements of the ISDS regulations. The installer of the system is to have demonstrated knowledge of
the APEHD ISDS regulations and requirements.
CHURCH & Associat V • : O O C �ST�
hGH S
:` 13172 s;
Edward O. Church, t0
�F •'•••.....••'N
ss�0 N AL EAG
EOC/trp
3 copies sent
000010
710 BILL CREEK ROAD
SW1 /4 & SE1 /4, SECTION 27, T8S, R88W
PITKIN COUNTY, COLORADO
0
0
0
0
F-`
1 PROPOSED BUILDING ENVELOPE
1 �
AREA TO BE USED
\ FOR FUTURE OWS
BUILD -OUT
I \
JONE 1250 -GALLON
TWO-COMPARTMENT'
PRECAST CONCRETE�•,��
SEPTIC TANK WITH
` PUMP IN BIOTUBE VAULT
IN SECOND
`COMPARTMENT
DISTRIBUTION
\ BOX
2" Pvc
PUMP LINE \
1
CLEANOUT
APPROX '"/ATE LOCATION OF
TWO BVDROOM PROPOSED
RFCIIIiN('F
EXISTING BUILDINGS
AND ENVELOPES
AL RIVER
WELL %!J
• •, ra
100 YEAR FLOOD PL
5iUALL
1 " = 100'
NO WELLS WITHIN 500 FEET
OF PROPOSED DRAIN FIELD
SITE PLAN, LOCATION OF
PERCOLATION HOLES, AND
LOCATION OF PROPOSED
OWS
1
IRRIGATION
` DITCH
l
Ii
279 SF OF INFILTRATIVE
AREA IN TWO
GRAVELLESS TRENCHES
I WITH CHAMBERS. EACH
I TRENCH MUST HAVE 1
ROW OF 9 CHAMBERS
I IN50 FEET SETBACK TO
IRRIGATION DITCH
1
�E---DRIVEWAY ENVELOPE
I
I
I
i
STING DRIVEWAY
JOB NO. 11948 FIGURE 1
El
r-.13
TYPICAL PLAN VIEW - N.T.S.
4" SDR 35 PERFOR,
PLACED ON GROUN[
TO MANUFACTURER!
3'T_
TYPICAL CROSS-SECTION -N.T.S.
4' SDR 35 PVC TOTAL - TWO TRENCHES
__-------OBSERVATION/VENT PIPE
WITH CAP
ACKFILL EXTENT OF EXCAVATION
3' MAX
S
' MIN. LOPE FOR DRAINgGE
1.5' MIN
GRAVELLESS CHAMBER
3' BY 6.25'
CALCULATIONS AND SPECIFICATIONS
DESIGN CRITERIA
RESIDENCE — 2 BEDROOMS, <2000 SF
LOADING — 75 GAL/DAY/PERSON
TOTAL LOADING — 300 GPD
PERCOLATION TEST — 14 MPI
AREA — (1.75 X Q XRT)/5
AREA — 393 SF
REDUCTION FOR USE OF CHAMBERS — 30%
TOTAL AREA — 275 SF
ON BOX
TYPICAL DISTRIBUTION BOX - N.T.S.
3' APPROXI
PLAN
VIEW Z
r—
im
1
1' APFROX.
TRENCH SPECIFICATIONS
NUMBER OF TRENCHES — 2
LENGTH OF EACH TRENCH — 56.25 FEET, 9 CHAMBERS
WIDTH OF EACH BED — 3 FEET, 1 CHAMBERS
TOTAL NUMBER OF CHAMBERS — 18 CHAMBERS
TOTAL AREA — 279 SF
DRAIN FIELD DETAILS
CONCRETE DISTRIBUTION
BOX
4" SDR 35
PVC PIPE
r—INLET
INLET OUTLET
VIEW MEW
�5
* MINIMUM OF FOUR OUTLETS NEEDED
TREATMENT UNIT SPECIFICATIONS
TOTAL CAPACITY — 1.75 X 0 X (30 HOURS/24 HOURS) _
657 GALLONS
RECOMMENDATION — ONE 1250 GALLON TWO COMPARTMENT
PRE—CAST CONCRETE SEPTIC TANKS WITH A PUMP IN A
BIOTUBE VAULT
TO 8"
1.5' APPROX.
1' APf ROX.
s
INLET OUTLET
VIEW MEW
�5
* MINIMUM OF FOUR OUTLETS NEEDED
TREATMENT UNIT SPECIFICATIONS
TOTAL CAPACITY — 1.75 X 0 X (30 HOURS/24 HOURS) _
657 GALLONS
RECOMMENDATION — ONE 1250 GALLON TWO COMPARTMENT
PRE—CAST CONCRETE SEPTIC TANKS WITH A PUMP IN A
BIOTUBE VAULT
co
E
a>
litT
(m so
C
000013
A_'
'dC
U
O
V
E
w D
u w = o
cL
((N .0ZX[]
07 •V
O 1i W
n
y
€ ^
0
a
\ a
v ri LL
t
.Q-
CEL
CL
rL
Q
c
yy
T
UW 7
a�
0 _]
C 0y7
FDS J6
Q' U ?
M W
a
O
O
r? .1-11 rr)
vo
oC' w
1� v�
W LZ
w
to
2
N
C" U
to
E
N C
rn W
a
M ch
� o
ao
Q1
6
z
a
a
Or
0
v
v�
N
0
O
N
Y) O
1030H011 PeaH aiweu'SO P101
O
QJ
Q
LL7
N
O
O
O
V
O
M
O
O
O
L LU
(]
d
r"
W
i
4l N (U )
N (D 0) Q) O L±1
<t r O O 117 LO
N 4
M M O O
v
CL
0
v
QZ:
u�,
0
(ll O
Q
Q1
z
a
o o
O
O
U
y
(]
D
3
S J
Cf1
_1
d
s
w
v
o
J =
O
i -
I,
d
y
E
iAooia
moll
I'll
0.
1
I
mill
in
I
Emilio
I
INF
Ell
oil
Us
on
on
v�
N
0
O
N
Y) O
1030H011 PeaH aiweu'SO P101
Q>
O
QJ
Q
LL7
N
O
O
O
V
O
M
O
O
O
L LU
(]
d
r"
W
4l N (U )
N (D 0) Q) O L±1
<t r O O 117 LO
N 4
M M O O
v
CL
0
v
QZ:
u�,
0
(ll O
Q
Q1
z
Q>
N C N
QJ
0
.�
N
4
4>
Q. .a
� N
L LU
(]
d
W
CL
CV G>
v
QZ:
u�,
(ll O
Q
Q1
a
o o
O
O
U
y
(]
D
3
S J
Cf1
_1
d
s
w
v
o
J =
O
i -
I,
d
y
E
iAooia
0
h
0
M
='l
E
APPENDIX A
HP GEOTECH
SUBSOIL STUDY AND PERCOLATION TEST
HABERMAN RESIDENCE
710 BILL CREEK ROAD
P1TKIN COUNTY, COLORADO
JOB NO. 199 827
NOVEMBER 15, 1999
000015
Todd Haberman Construction
November 15, 1999
Page 5
Percolation Testing: Percolation tests were conducted on 1:9, :4999 to evaluate
the feasibility of an infiltration septic disposal system at the site. One profile pit and
three percolation holes were dug at the locations shown on Fig. 1. The test holes
(nominal 12 inch diameter by 12 inch deep) were hand dug at the bottom of shallow
backhoe pits were soaked with water one day prior to testing. The soils exposed in the
percolation holes are similar to those exposed in the Profile Pit shown on Fig'. 2 and
consist of about 1'/z feet of topsoil and 3 feet of medium dense silty sand overlying
relatively dense silty sandy gravel with cobbles. The percolation test results are
presented in Table II. The percolation test results indicate an infiltration rate between
12 and 17 minutes per inch with an average of`' ° JWh. Based on the
subsurface conditions encountered and the percolation test results, the tested area should
be suitable for a conventional infiltration septic disposal system.
Limitations: This study has been conducted in accordance with generally accepted
geotechnical engineering principles and practices in this area at this time. We make no
warranty either expressed or implied. The conclusions and recommendations submitted
in this report are based upon the data obtained from the exploratory pits excavated at the
locations indicated on Fig. 1, the proposed type of construction and our experience in
the area. Our findings include interpolation and extrapolation of the subsurface
conditions identified at the exploratory pits and variations in the subsurface conditions
may not become evident until excavation is performed. If conditions encountered
during construction appear different from those described in this report, we should be
notified at once so re-evaluation of the recommendations may be made.
This report has been prepared for the exclusive use by our client for design purposes.
We are not responsible for technical interpretations by others of our information. As
the project evolves, we should provide continued consultation and field services during
construction to review and monitor the implementation of our recommendations, and to
H -P GEOTECH
000016
6' �at, 642 6430 6440 6450 6460
A \ Z�
c— — -----1 \ \6460
BUILDING
VELOPE
7� 6450
AN �\
--
��! / DEVELOPMENT
_ N ENVELOPE
P 3 �
I P 2A J
\ PROFILE
P 1 PIT
� J
r�
L J
EXISTING
CARETAKER
UNIT
IT 1�
FXISTINC;
/%A / ] "r OU I HUILDHIGS
r
I
�. EXISTING
STABLE
rr
. /
EXISTING
/ ( � RESIDENCE
._ J APPROXIMATE SCALE
1 6390 6400 6410 6420 <--�30 6440 1 " = 100'
199 ,277HEPWORTH - PAWLAK LOCATION OF EXPLORATORY PIT Fig. 1
GEOTECHNICAL, INC. I AND PERCOLATION TEST HOLES
000017
--r
r Disturbed bulk sample.
NOTES:
1. Exploratory pits were excavated on October 18, 1999 with a trackhoe.
2. Locations of exploratory pits were measured approximately by pacing from features on the site
plan provided.
3. Elevations of exploratory pits were measured by instrument level and refer to the Bench Mark
shown on Fig. 1. Logs of exploratory pits are drawn to depth.
4. The exploratory pit iocation5 ono elevubuns anu—u oc w„sidcred uceu;-o.c cr,:y t:, :i
implied by the method used.
5. The lines between materials shown on the exploratory pit logs represent the approximate
boundaries between material types and transitions may be gradual.
6. No free water was encountered in the pits at the time of excavating.
Fluctuations in water level may occur with time.
7. Laboratory Testing Results:
WC = Water Content ( % )
DD = Dry Density ( pcf )
-200 = Percent passing No. 200 sieve
199827 I HE WOECHNIC PAWLA I LOGS OF EXPLORATORY PITS I Fig. 2 I
=1
PIT 1
PROFILE PIT
ELEV. = 94'
ELEV. = 99'
0
0
We=e.2
: DO -106
'
�
-
o- -200=34
1
5 � `•a
'' _r
:o 0
5
.o`••
.. •
•a.
WC=4.4
DD -105
O 4•
, aE
10
10
LEGEND:
TOPSOIL; silty sandy clay, stiff, moist,
brown, organic.
-•
SAND (SM); silty, with gravelly lenses,
medium dense, slightly moist to moist,
light reddish brown,
slightly calcareous.
GRAVEL (GM); in a silty sand matrix with scattered cobbles, medium dense to
dense, slightly
'°•
moist to moist, light reddish brown, slightly
calcareous.
2" Diameter hand driven liner sample.
--r
r Disturbed bulk sample.
NOTES:
1. Exploratory pits were excavated on October 18, 1999 with a trackhoe.
2. Locations of exploratory pits were measured approximately by pacing from features on the site
plan provided.
3. Elevations of exploratory pits were measured by instrument level and refer to the Bench Mark
shown on Fig. 1. Logs of exploratory pits are drawn to depth.
4. The exploratory pit iocation5 ono elevubuns anu—u oc w„sidcred uceu;-o.c cr,:y t:, :i
implied by the method used.
5. The lines between materials shown on the exploratory pit logs represent the approximate
boundaries between material types and transitions may be gradual.
6. No free water was encountered in the pits at the time of excavating.
Fluctuations in water level may occur with time.
7. Laboratory Testing Results:
WC = Water Content ( % )
DD = Dry Density ( pcf )
-200 = Percent passing No. 200 sieve
199827 I HE WOECHNIC PAWLA I LOGS OF EXPLORATORY PITS I Fig. 2 I
=1
.. .
HEPWORTH-PAWLAK GEOTECHNICAL, INC.
TABLE it
PFRCOLATION TEST RESULTS JOB NO. 199 827
Note: Per'ColdtiorI ta3t hUles were hand dug in 6::.......-1 �i LLKIIUt: ,P:.:- alli jod:G(_PLi . _ , I "':.19. -1,110 ? I:
were protected from freezing overnight with rigid foam insulation. Percolation tests were conducted on October 19,
1999. The average percolation rates shown were based on the last three readings of each test.
000019
WATER DEPTH
AT END OF
INTERVAL
(INCHES)
DROP IN
WATER
LEVEL
(INCHES)
AVERAGE
PERCOLATION
RATE
(MIN./INCH)
HOLE NO.
HOLE DEPTH
(INCHES)
LENGTH OF
INTERVAL
(MIN)
WATER DEPTH
AT START OF
INTERVAL
(INCHES)
P-1
50
10
101/4
81/4
2
12
81/4
63/4
1 1/2
6 314
5314
1
53/4
43/4
1
43/4
4
3/4
4
31/4
3/4
P-2
62
10
93/4
81/4
1 1/2
17
81/4
7
1 1/4
7
6
1
6
51/4
3/4
51/4
43/4
1/2
43/4
41/4
1/2
P-3
56
10
83/4
63/4
2
13
63/4
51/4
1 1/2
51/4
41/4
1
41/4
31/2
3/4
3 112
21/2
1
21/2
2
1/2
Note: Per'ColdtiorI ta3t hUles were hand dug in 6::.......-1 �i LLKIIUt: ,P:.:- alli jod:G(_PLi . _ , I "':.19. -1,110 ? I:
were protected from freezing overnight with rigid foam insulation. Percolation tests were conducted on October 19,
1999. The average percolation rates shown were based on the last three readings of each test.
000019
0
DOTED EDGE REPRESENT
WERE THE GROUND SL❑F
DOWN TO THE RIVER
VALLEY FLOOR,
@400F
IS PLAN
s 00 i•=w'—o•
DOTED LINE REPRESENTS TOP
h 11 OFBOULDAER WALL ANDle N
DRIVE
000020
z
Q
Z
❑ 5 10 20
1u, _ 10'
BASIS Cr HEARING = EXISTING STRUCTURE
CONTOUR INTERVAL > V
NORTH
NOTES: 0
I. DIMENSIONS ARE TO FACE OF ROUGH FRAMING
Jim
CA
v
uil
l7j
W
jV
.� �.
q1l
Limits Of Mapping.
.r+'
1•"94 x
ti7C it1.n yC.
—~
o e e a e
e
o t Df B ild
nx
�u
v
_
a.
a
o6 a
t,
i 0 �, �✓
otal /
Ao
1
Orth Bill
reek Roa
B>ildiag ve •
\ to Hwy 133
/
A30
6
� 100w.Ye
iY9
p
y,
64 DO
6390
0
Current ge o River,
®
M
ami
a�
S�
N
O
L0
a
N O O
r
t ^.
y
rwwH BRASS CAP
S 1/4 COR.. SEC. 27
POUND REHA11 W 63g0
Property Boundar
'
Property Boundary
w.
0022
(D
o
a
a
DESIGN WORKSHOP
120 East Main Street
ASPEN,COLDRAD30 61611
Facalmle )(970) 920-1387
Albuawrque . Aspen• Deliver
Jackson Sao Paula- Santa Fe
Temps • Lake Tahoe. Vol
Lands kchlteauue • Lana Planning
Ikbm Dedr . TamWn Planep
H!
li
r1
SITE
UTILIZATION
PLAN
111111110
PROPOSE
DEVELOPMENT
PLAN
LEGAL
DESCRIPTION:
SWI/4 SE1/4
SEC 27 T8S
R88W/SURVEY BY1
LINES IN SPACE
BOX 121
CARB❑NDALE
DATE DESCRIPTION
10.9198
T--
REV.-
ISSUE
—REV:ISSUE
DATE:
DRAWN:... REVIEWED
scale 1."=50'
0 25 50 100
PROJECT NUM: 1912
DOREEN
GOLDYN 1041
REVIEW
SHEET NUNBER
4 OF 4
QW.Yea,T eeneeraawQr lxc, n..r
1 FOUNDATION PLAN
SCALE: 1/4"=1'-0"
0000123
NOTES: 0
I. DIMENSIONS ARE TO FACE OF ROUGH FRAMING
r'r'I ■
■
■ Inlllllll ■
MCOTTLEYAW■
■GRAYBEAL
■
LTD
■ ■
■510 EAST HYW ■
■ASPEN, CO. 81611■
■P 970)925-2867■
■ �970)925-3736■
■
P,O.BOX 3507■
■107 NORTHTEMURI■
■ ' 81435
, ■
■ 'I F 970)728-3236■
■■■■■■■■■■
momon ONE
■■■■■■■■■■
■■n■■■■■■■
■■■n■n■■nn
■■■■■■■n■■
■■■■■■■■■■
■■■■■■■■■■
GOLDYN
RESIDENCECARETAKER
■ITKIN1
UNTY
COLORADO
11
SEEM 3- 311SEEM■I
■■■■■i
■■■■■■■■■■
■■■■■■■■■■
iiiiiiiiii
■■■■■■■■■■
iii■moiin■ii
■■■■■■■■■■
mostolloom
■■■■■■■■■■
■■■■o■■■■■
■■■■■
sono■■■■■■
■■s■no■■■n
M■■■■■■■■M
� Er
■ ■
r-^
■m■■M■■■■N
a\
1
+t
17
1
NEW
NEWS:ZIP MR AM i -
� . - • � � -fib '�.
MCA
w
fill
i) G
DESIGN WORKSHOP
120 East Main Street
ASPEN. COLORADO 81811
(970) 925-8354
FaosimBe (970) 920-1387
Albuquerque . Aepen• :Denver
Jadroon Bao Poulo• Santo Fe
Tempe • Lake Toho. Voll
Laedeowo Arahiteotun • Lmd Planning
Urban Door . T—M. Plannhq
islMoNdo
WI
A �I�
a
V �
�I
SITE
UTILIZATION
PLAN
LEGAL
BASEMENTS
LEGAL
DESCRIPTIONI.
SW1/4 SE1/4
SEC 27 TSS
R88W/SURVEY BYi
LINES IN SPACE
BOX 121
CARBONDALE
# DATE DESCRIi TION
ins/ii/isee
_ H0I9i98
REV:_
ISSUE
DATE:
DRAWN:,. RENEWED::
Scale
0 25 so 100
MISSION
PROJECT NUM: 1912
DOREEN
GOLDYN 1041
REVIEW
SHEET IA111But
1
OF 4
H'JaOrTel Oni O[EWNNp11WHpp IeO. Heel /
a
m
t,
,�,� ♦.
�� 10
4
,'
`Alm
EdI��
-rIL�
ti
I e•
1
DESIGN WORKSHOP
120 East Moln Street
ASPEN, CDLDRADO 81811
Foctimlle (970) 920-1387
1387
Albuquerque • Aspen- Dwwr
Jadawn Soo Paulo- Santo Fe
Tempo • Lake Toho. Val
Lawefmpe ArehMckrte • law Phminq
alae owls . Tpf1e plelnfq
i
Q � �
a �
�j
SITE
UTILIZATION
PLAN
SLopir
LEGAL
DESCRIPTIONI
SWI/4 SEI/4
SEC 27 T8S
R88W/SURVEY BY,
LINES IN SPACE
BOX 121
CARBONDALE
# DATE DESCMOON
1W..'8 T
_ TI
REV:_ I
ISSUE
DATE:
DRANN:_REMEWED;
a
scile 1."=S0'
b zS .. So100
PROJECT NUM: 1912
DOREEN
GOLDYN 1041
REVIEW
%UT NUMBER
3 OF 4
n11eNf l•eleNeeeffllef INC. few
w
1ESIGN WORKSHOP
20 East Main Street
ASPEN, COLORADO 81811
FaasM(rlle )(970) 9820--1387
UMpuergre • Asper- Denwr
ICkson Bao Paulo. Santa Fe
Temps • Lake Toho Val
nee•epe ArdebeWn • Lend Plaxi•q
UPoon Dwp • T—f— Pww"
W
Z.
HI
TqI
JJ 1
1i
SITE
UTILIZATION
PLAN
ITE ANALYSIS
EXISTING
CONDITIONS
LEGAL
DESCRIPTI❑Ni
SW1/4 SE1/4
SEC 27 T8S
R88W/SURVEY BYI
LINES IN SPACE
BOX 121
CARB❑NDALE
# DATE DESCRIF TON
s_e/ay/tope
IM"
REV:
ISSUE
DATE:
ORANN**:���� REVIEWED.
i�
Scale
0 25 50 100
PROJECT NDN° 1912
DOREEN
GOLDYN 1041
REVIEW
91m NuwetER -
2 OF 4
cow ran owawawiwoP do, 1#0 - �
l
e
�
lir► �r/►' �-------�
i��l�t_�
,'� r. ;•r�••.>•rt t tR�s
� �
�
�
_
-
/,
',�_
/ / t �
`-' -.-- "rases-
Lam._
� �
-
��•
,•` �A�
�
�
)I •' F
`C a�i "�"',9!7"'r �! T�^7�
, �.='-
_�Ir7�_�7.� R.'C�i`�'e ��aT�r� .
�`SAM
a
'�—..�� -moi.•; ��
�:\�
Is WSMC
-M
WINDS
am
IT,
LOW
1 r r r. ME
,-
WE,
r —�
tea,
Rive'r As Per
1ESIGN WORKSHOP
20 East Main Street
ASPEN, COLORADO 81811
FaasM(rlle )(970) 9820--1387
UMpuergre • Asper- Denwr
ICkson Bao Paulo. Santa Fe
Temps • Lake Toho Val
nee•epe ArdebeWn • Lend Plaxi•q
UPoon Dwp • T—f— Pww"
W
Z.
HI
TqI
JJ 1
1i
SITE
UTILIZATION
PLAN
ITE ANALYSIS
EXISTING
CONDITIONS
LEGAL
DESCRIPTI❑Ni
SW1/4 SE1/4
SEC 27 T8S
R88W/SURVEY BYI
LINES IN SPACE
BOX 121
CARB❑NDALE
# DATE DESCRIF TON
s_e/ay/tope
IM"
REV:
ISSUE
DATE:
ORANN**:���� REVIEWED.
i�
Scale
0 25 50 100
PROJECT NDN° 1912
DOREEN
GOLDYN 1041
REVIEW
91m NuwetER -
2 OF 4
cow ran owawawiwoP do, 1#0 - �
Now
q'141 - ;ZPy-00 �7 88
PITKIN COUNTY HEALTH DEPARTMENT
PERMIT NUMBER / Z RECEIPT NUMBER ?),/Jg-*S;Z
Owner ��"� Phone No. 91/3- 3179
Owner's Mailing Address ®147'x-'"
Contractor'''"-� !'ifs-� c c_c�& s� Phone No.
Address SW GG 3 - ��� (� �� cf�L1 3
System's Contractor's Name
Address
Legal Description sW S ,Q��.• 017, `�yu"w` y� S - q�" +�� ��
Lot Size �D aC a� Type of Building by Use U�
Number of Bedrooms '3 Type of Water Supply
i
Owner's Signature ��' Date
PLOT PLAN: ATTACHED AS RE I RED
Type of Individual Sewage Disposal System ,�/c �iga/fc
Type of Soil or Soil Classification -51ld-I-X45j;y
Proximal Location of Bedrock LX°T r%E���l-E�IT %f g FT
Proximal Location of Ground Water Table /J®T QET /��I_**�Tfe 72ZO(40 15;,F_7._
Percolation Test Date 9"2_7- 7L - 17 Minutes Per Inch
Minimum Recommended Absorption System Size l 3D —`4 - FT
Minimum Recommended Tank Size A'DOD GAI-1-DAIS
Special Conditions of Issue: NOTICEP � When properly signed for issuance, this application
becomes your permit. Application valid one year from
date. If an individual sewage disposal permit Is issued
for property on which no building permit has been
A issued, the individual sewage disposal permit shall
expire 120 days after its issuance If construction has
not been commenced. Any change in plans or speci-
fications after the permit has been issued invalidates
the permit, unless approval is secured from the Health
Officer for such changes.
Approved for Issuance By Date
/O /5--,79
dF 1! iF iF 1F iF iF �F iF * * ik 1F iF iF M k iF dF it iF it dF �F �F it it it # it it it it iE lF if # iF it iF * iF it it �: it it t * it it if it * it it it iF it iF it it it * it it it it it M'i�t/1i/fit iF it it iF it it 1t iF �F �F iF it N dk it it iF
�winnr�T�nLI Anil Mn\/AI I��IlI/.�`nta
(Drawing of System on Back) U0G I '.1 �,UUOU
0
E&
506 E. MAIN STREET
P
I
T
K
I
011
)002 T
Mr. Jim Stevens
P.O. Box 663
Carbondale, Colorado 81623
ASPEN, COLORADO 81611
October 3, 1979
Re: Individual sewage disposal system for the
Pat Taylor residence
Dear Jim:
Enclosed please fine a sewage disposal permit
application for the referenced property. This
should be completed and returned to us as soon
as possible. The permit fee is $75.00.
We have already completed the percolation test,
andthe rate was 17 minutes per inch. This means
for a three bedroom house, the county regulations
require approximately 630 square feet of Littom
area for any leach field.
If your have any further questions, please call.
RFN/mh
Sincerely,
Robert F. Nelson,
County Sanitarian
Y
14