Loading...
HomeMy WebLinkAboutpitkin.eh.246322100020 (1999)Document Layout (From Most Recent to Oldest Permit) Permit Application Log Sheet/Notes & Photos Communications As -built Design Engineer Design Soil Information Water Permit & Information Second System on property Third System etc. Floor Plans Please See Building and Land Use Approvals Files for additional information. Permit # 99102 Aspen/Pitkin Environmental Health Department Permit for an Individual Sewage Disposal System 130 S. Galena St. Aspen, Colorado 81611 Phone 970-920-5070 / FAX 970-920-5074 Parcel ID # 2463-221-00-020 Type of permit New( x ) Repair( ) Addition to House( ) Name of Owner William Street Address 316 N. Thomas Rd, Carbondale Properly legal description Size of lot 37 acres Water source private well Total square footage of the house # of bedrooms in house If of offices, lofts & similar sized rooms in house Caretaker unit yes Total square footage of the caretaker unit 400 sq feet # of bedrooms in caretaker unit 0 # of offices, lofts & similar sized rooms in caretaker unit Designed for what # rooms (list) 2 (two) Designed by Mailing Address Perc rate 23 Permit information Dave Powell, Timberline En PO Box 631, Carbondale, CO 81623 Profile hole depth 8ft Depth to groundwater or bedrock Septic tank capacity 1000 gallons Absorption area 353 square feet Comments unknown Septic permit approved per compliance with the engineer design and specifications dated November 21,1999. Any changes must be approved by this department and the design engineer prior to them being made. Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin County ISDS regulations. This department does not endorse any brand of products. System designed for the caretaker unit includes a 1000 gallon tank and 24 Infiltrator Units (6x4) in a bed configuration. Setback from irrigation ditch and must be at least 50 feet. Horse traffic over the absorption bed should be kept to a minimum. Permit approved by: 6216 LOLL _ Date:I�kq�— Plans and specifications of the proposed individual sewage disposal system have been reviewed and are considered satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was issued unless system construction has commenced or an extension has been approved in writing by the Department. As -built drawings must be included with this permit before the final approval will be issued. Installer: 0Ur7 � O�OT 1 ' y�11 j ma nspection approval: h � n fl dL Date: OCT -25',99 MON 02:51 PM ASPEIITKIN ENV HEALTH FAX:970 920 5074 ASPEN 1 l KIN ENVIRONMENTAL HEALTH DEPAR I MENT APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM 130 S. Galena St., Aspen Colorado 81611 Phone 970-920-5070/Fax 970-920-5074 WUF Name of OWNER / r/r/i�yEjj�C / Owner ,/, //zi/s Mailing Address _0,16 — r AV �bp? , 5216Z3 Business Phone: Home Phone: — 96,? S -7,Z/ 063 /678 Primary Contact Person (all communication regarding this permit wi0 go through this person) Name Contact Mailing Address Business Phone 463 S// - Cell // - Cell Phone eU gi< 3 /6'78 rarcei to a tavanacte from assessors orrice at 920.5160 or at www.aspen.comlas/sissor� �- 6 3 - 2 / - O O - D Z- O Street address of property 3/6 — A/o, lo�d _CQLZ41 Legal Description: Lot _ ,Block ,Filing ,Subdivision Size of lot. -37-t acres. Type of proposed structure: CDL/ Size of 3Idg. envelope: D. Total square feet of house # of bedrooms in house 4112w- 9 of offices, lofts B similar sized rooms in house Caretaker Unit: Attached( ) Detached( //) Total area(sq. R.) of caretaker tnfit _ # of bedrooms in caretaker unit O n e- X of offices. lofts and similar size rooms of caretaker unit Permit is for: New Home ( ) Repatr due to failure ( ) Remodel/Addhion ( !f) Emergency use ( ) Water. Private wen ( Spring ( ) Stream ( ) Community/Public Water System ( ) If community system: Name of system The fee for a ISDS application is $330 for a permit that takes 6 hours or less for the department to approve. If approval takes longer than 6 hours, a rate of $55 per tour will be charged. The maximum fee is 51000. The basic fee of $330 is due at the bine of application, The remaindw, if any, will be due in two stages: first, at the time of issuance of the ISDS permit; second. before final approval of the ISDS permit. Application for an individual sewage disposal syst- - is hereby submitted. I hereby certify that the above information is true and accurate and that I have provided true and accur 3 information on locations of all existing and proposed wells, contour intervals, buildings. property lines, ditches, 310pds. waterlines, springs, suction or irrigation lines, drinking water cisterns, drain tiles. imgation ditches, lakes, water courses, streams, floodplams, dry gulches, and existing septic systems. I hereby certify that any such features riot shown On attached site map are not present. Issuance of the pennil does not imply the approval of any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all approvals and permits have been obtained. The Aspen/Pitkin Environmental Health Department. Pdkm County and employees of these agencies will be held harmless should the individual sewage disposal system fad or malfunction. The permit to construct is issued on information submitted by the applicant or hlslher representatives. The owner assumes full responsibility in case of failure of the system. Signature of applicant Received by 000002 Date /a/g. Receipt # j 3 Date 1 11�1IG31=.11 .11. IME IF: .\( fl, 1011: 0 STRUCTI.IRAII./CEVU, IENGENIE]ERIING ♦ CONTRACTIING ♦ CERTMED`)uN ERGY DESIGN PROIFIESSIIONAIL August 8, 2000 Pitkin County Environmental Health Attn: Nancy MacKenzie �7 130 South Galena Aspen, Colorado 81611 AUG 1 0 2000 Re: LSDS Installation ENVIRONMENTAL HEALTH Permit # 99102 ASPEN / PITYJN Myers Residence 0316 North Thomas Road Carbondale, CO 81623 Dear Nancy: The installation of the ISDS for the above residence has been completed and has been installed in accordance with applicable county specifications and the approved plan. Enclosed is the as - built drawing for the system. If you have any questions, please call me at 963 -9869 - Sin �rely�, David A. Powell, PE Reg. No. 25851 cc: Myers Residence 0316 North Thomas Road Carbondale, CO 81623 000003 P.O. BOX 631 CARBONDALE, CO. 81623 PHONE 970 963 9869 / FAX 970 963 9003 July 24, 2000 To: Pei A do, Yi WM 1 RE: CC: Dear Prrtax COUNTY ENVIRONMENTAL HEALTH DEPARTMENT This letter is to advise you the we have not been able to final the Individual Septic Disposal System (ISDS) permit for the above stated residence/property. It is of utmost importance for the Environmental Health Officer to final all ISDS permits once proper installation and required inspections are complete. We cannot sign the Certificate of Occupancy for this property without the "As Built" letter. It is mandatory that this, office receive an "As Built" letter from the engineer who designed the system. An "As Built" letter will confirm that they observed the installation of the system as designed. Any changes to the system must be noted in the "As Built" letter or by a new set of plans. This office must receive the "As Built" letter from the engineer no later th 15 2000. Please contact me with any questions. Thank you, in advance, for your help and co-operation in this matter. Sincerely, 00 Madelyn Blumenthal Pitkin County Environmental Health 46 000004 130 SOuTH GALENA STREET • ASPEN, COLORADO 81611-1975 - PHONE 970.920.5070 - FAx 970.9205074 w .npmgov.com/ehnm/cowry/indexJitml FMW wRe WPepe November 15, 1999 Bill Meyers 316 North Thomas Road Hep,O Pawlak Geotechnical, Inc. 5020 County Road 154 Glenwood Springs, Colorado 81601 Phone: 970.945-7988 Fax: 970-945-8454 hpgeo@hpgeotech.com Carbondale, Colorado 81623 Job No. 199 872 Subject: Percolation Testing, Proposed Art Studio, 316 North Thomas Road, South of Carbondale, Pitkin County, Colorado Dear Mr. Meyers: As requested, we have conducted percolation testing at the subject site to evaluate the feasibility of an infiltration septic disposal system. The results of our work are presented in this report. The work was done in accordance with our agreement for Professional Services to you dated November 5, 1999. A profile pit and three shallow backhoe pits were excavated on November 5, 1999. The septic area is located to the southeast of the two proposed buildings as shown on Fig. 1. Percolation test holes (about 12 inches in diameter and 12 inches deep) had been dug in the bottom of backhoe pits and soaked by the client one day prior to testing. The soils exposed in the percolation test holes and profile pit consist of about 3 feet of topsoil overlying silty gravel and cobbles with occasional boulders to the profile pit depth of 8 feet.. No free water was encountered in the pits and the subsoils were slightly moist to moist. The percolation holes appeared to be in topsoil. The holes were deepened into the underlying gravels and re -soaked on November 7, 1999. Percolation tests were performed in the percolation test holes on November 8, 1999 by a representative of Hepworth-Pawlak Geotechnical, Inc. The percolation test results are presented on Table I. The percolation test results indicate an infiltration rate between 13 and 36 minutes with an average of 23 minutes per inch. Based on the subsurface conditions encountered and percolation test results, a conventional infiltration septic disposal system appears feasible at the tested location. 000005 C C Bill Meyers November 15, 1999 Page 2 u If you have any questions or if we can be of further assistance, please call our office. Sincerely, HEPWORTH - PAWLAK Jordy Z. Adamson, Jr. .E. Rev. By: DEH JZA/sd attachments cc: 000006 INC. RE iv 2970 � `• FSS �N A���G� Timberline Engineering - Attn: Dave Powell A?PROXIMATE SCALE t"=50' TO T NOMAS Rn . _ 199 872 HEPWORTH - PAWLAKHNICALI LOCATION OF PROFILE PIT AND I Fig. 1 I GEOTEC, INC. PERCOLATION TEST HOLES 000007 HEPWORTH-PAWLAK GEOTECHNICAL, TABLE I PERCOLATION TEST RESULTS HOLE NO. HOLE DEPTH (INCHES) LENGTH OF INTERVAL (MIN) WATER DEPTH AT START OF INTERVAL (INCHES) WATER DEPTH AT END OF INTERVAL (INCHES) DROP IN WATER LEVEL (INCHES) AVERAGE PERCOLATION RATE (MIN./INCH) P-1 50 15 water added 7 51/4 1 3/4 20 5 1/4 4 1 14 7 1/4 6 1/4 1 6 1/4 5 112 3/4 5 1/2 43/4 3/4 43/4 4 3/4 P-2 53 15 8 7 1 36 7 6 1/2 1/2 6 1/2 5 3l4 3/4 53/4 5 1/4 1/2 5 1/4 4 3/4 1/2 43/4 41/2 1/4 P-3 52 15 water added water added 7 5 1/4 1 3/4 13 51/4 3 1/2 1 3/4 7 3/4 6 1 3/4 7 1/2 6 1/4 1 1/4 6 1/4 5 1 1/4 5 4 1 Note: Percolation test holes were hand dug and soaked by the client on November 7, 1999. Percolation tests were conducted on November £, 1999. The average percolation rate was based on the last three readings of each test. • 119111111!1 111111 IIII 111111 IIII I. _;l III IIIII IIII IIII 435781 09/22/1999 12:50P RESOLiTI onvIs SILVI 1 of 5 R 0.00 0 0.00 N 0.00 PITKIN COUNTY CO RESOLUTION OF THE BOARD OF COUNTY COMMISSIONERS OF PITKIN COUNTY, COLORADO, GRANTING A MINOR AMENDMENT TO A BUILDING ENVELOPE AND SPECIAL REVIEW APPROVAL OF A DETACHED CARETAKER DWELLING UNIT AND MINOR BUILDING ENVELOPE EXPANSION ON THE MYERS PROPERTY Resolution No. 99-11-53 RECITALS I. Bill Myers, lherea@er "applicant " has applied to the Board of County Commissioners of Pitkin County, Colorado, hereafter, "Board," for a special review approval of detached caretaker dwelling unit and a minor building envelope expansion. 2. The Property, described in Exhibit A, is located at 3 16 N. Thomas Rd. 3. The lot is 37 acres and zoned RS -30. 4. The Board heard this application at a public hearing on August 25, 1999 at which time evidence and testimony were presented with respect to the application. 5. The Board finds that the application complies with the applicable Code Sections. NOW, THEREFORE, BE IT RESOLVED by the Board that it does hereby grant approval of the Myers detached caretaker dwelling unit and minor building envelope expansion subject to the following conditions which shall run with the land and be binding on all successor in interest: 1. The applicant shall adhere to all material representations made during the application process. 2. A caretaker dwelling unit deed restriction shall be recorded with the Housing Office prior to issuance of a building permit for the CDU. The applicant shall comply with all Housing Authority guidelines for CDUs. Floor plans of the proposed unit calculating the net livable square footage shall be submitted to and approved by the Housing Office prior to building permit approval. 3. There shall be one off-street parking space on the property for each bedroom in the CDU. 4. Prior to issuance of any building permits the applicant shall obtain approval of an ISDS permit from the Environmental Health Department. The septic system must comply with all minimum horizontal setback requirements between its components and physical features. A qualified professional engineer must design the system. The septic system shall be located within the building envelope. 5. No building permits for residential use shall be submitted until the intersection of Highway 133 and Thomas Road has been improved to ensure the safety of the traveling public to the satisfaction of the Colorado Department of Transportation (CDOT) and the County Engineer. If the owners of the property illegally construct the caretaker unit, the use will be revoked and no longer allowed on the property. 6. Prior to the submittal of building permits, the Applicant shall be in compliance with Resolution PZ 91-33 and BOCC Resolution 91-83. Y 1 MI q9 -asp O 111111111111111111 "l 111111 IT 11111111111111111VIS 11 IN LVI 2 of 5 R 0.00 D 0.00 N 0.00 PITKIN COUNTY CO Myers Caretaker Dwelling Unit Page 2 of 3 7. The Applicant shall comply with the following wildfire mitigation conditions with regard to development in the lower building envelope (the "barn envelope"): A. Applicant shall establish and maintain a ten foot perimeter around all structures in the barn envelope where vegetation is no taller than six inches. Woody vegetation shall not be planted nor shall flammable material be stored within this perimeter. B. A ten foot spacing shall be maintained between the outside edges of the crowns of all trees (including future landscaping) for a thirty foot perimeter around the caretaker unit/agricultural structure buildings complex. C. Roots shall have a Class A, non-combustible roof system. Flat roofs (up to a 4:12 pitch) and wood shake shingles shall be prohibited. D. Vents shall be screened with corrosive resistant wire mesh with mesh 'A inch maximum. E. All development associated with the proposed affordable housing unit shall ineet all code requirements of the Carbondale and Rural Fire Protection District. F. The proposed pond shall be accessible to Fire Department Vehicles in the event of a wildfire. G. Roofs and gutters shall be kept clear of debris. H. Yards shall be kept clear of all litter, slash, and flammable debris. L All flammable materials shall be stored on a parallel contour a minimum of 15' from any structures. J. Firewood shall be stacked on a parallel contour a minimum of 15 feet away from any structure. K. Propane tanks shall be installed according to NFPA 48 standards and on a contour away from the structure with standard defensible space vegetation mitigation around any above- ground tank. Any wood enclosures around the tank shall be constructed with materials approved for 2 hour fire -resistive construction on the exterior side of the walls. L. Fences shall be kept clear of brush and debris. M. Wood fences shall not be connected to the structure. N. Fuel tanks shall be installed underground with an approved container. O. Each structure shall have a minimum of one 10 Ib. ABC fire extinguisher. P. Addresses shall be clearly marked and visible with minimum 2" non-combustible letters and shall be clearly visible at the primary point of access from the public or common access road and installed on a non-combustible post. Q. Any outbuildings or additional buildings shall adhere to the same standards as structures. 8. No development, including grading, landscaping, vegetation removal or disturbance, and septic system shall occur outside of the approved access and building envelope except as may be necessary to implement the wildfire mitigation measures required elsewhere in this approval. 9. The Applicant shall adhere to all material representations made in the application and public meetings. 10. The vested rights established pursuant to this approval shall expire on August 25, 2002. 000010 435781 09/22/1999 12:50P RESOLUTI DAVIS SILVI 3 of 5 R 0.00 D 0.00 N 0.00 PITKIN COUNTY CO Myers Caretaker Dwelling Unit Page 3 of 3 NOTICE OF PUBLIC HEARING PUBLISHED IN THE ASPEN TIMES ON JULY 24,1999. APPROVED AND ADOPTED ON THE 25TH DAY OF AUGUST, 1999. NOT)CE OF STABLISHMENT OF A VESTED RIGHT published in Aspen Times Weekly on the J5�dayor.: rirj` , 1999. ATTEST: L , ee ean, Deputy Clerk and Recorder APPROVED AS TO FORM John Ely, Coue ttorney Case #P80-99 Parcel I.D. # 2645-143-00-017 carevm109/01/99 000011 BOARD OF COUNTY COMMISSIONERS OF PITKIN COUNTY, COLORADO APPROVED AS TO CONTENT "n, Cindy Houben Community Development Director " Leslie 1. Lamo t Chair,gy �^i %� a 1 I.C , APPROVED AS TO CONTENT "n, Cindy Houben Community Development Director .342699 B-784 P-701 06/27/95 10:40A PG 2 OF 3 J - Exhibit "A" 388690 B-803 P-519 12/29/9� 02; N H .,�0P PG 2 OF*3 -N Z M f� ®au 71n land rePcztad to in the Ca,,itlent is ecwsr>ng the larxi in the State of Z Colorafb, Cotarty of Pi-. ki, , de,=ibed as folla+s: j F A Parcel of land situatod in Section 22 and Section 23, 4txttsh3 e South, Barge Bo '.rest of t. -e 6th Principal Neridlan, b Log mc¢a p ®N Particularly de_sclbed as follows: Sa#ryring at a point -frrr:m thn North 1/4 correr of said SaoUm 22 ecce 4. t9 Josars Morth 65" 25' 40" Wast, 3.413.28 feet; tttttttttt•B�j = trrnm South 35'11'11" 'test, 673.42 feet to a mint m the forth Lira � CD of thO Pitt n rcu tr^a-- �aRamcLjptlon to, 254931 of the ztamrt'a -m trrzn, alorg the North lire of said Psxptim No. 254931 North 62.18'00" West, 663.86 feet alarl said K7rth Nim: thence Norh 35' 11'33" East, 23.32 feet to a fence comer; CD thace North 58.04'35" West, 90.26 feet al crq ®No t`Iarce North 64.15'26" lees t, 145.48 fent al a canoe; eg a fero,; =mo theme North 62'53'38':, 11295.20 feet alar3 a fence to a hint on m cc the Ear6Crly lira of a ParcelBook of lard krsa n a, 1`arer:l A, ear-...-.. In � Recorder; ttttttttttw Sat FaOe 613 01 Via co=rds of t1r Pitkin County Cork aryl o- rp =tn ° _thence, aloYj tin East line cf said ?arcx•1 A the following live (5) -vv I. North 32"11'59" East, 8.60 feet; 2. theme North 42'08'47" East, 36.29 feet: 3. thence. North 62' 52' 28' East, 109.44 fent: 4. UW100 North 36'13'16' East, 123.14 feet: 5. the oO t+octh 18'44'09" East. 55.00 feet to tin Sorthaast cor*+er of pcel of Sind kr as Parcel C desrsionl in 0.vk 459 at P tarhe records of VY! Pitkin County .Clerk and launder; °g° 298 of then almcl tln Fast lira of Will ParQ1.C, Nbr",;h 18'44'09" Fast, 24.57 feet; the South 89'56'33" Fist, 1.90 feet to ten Swtheast corgi of a pazoal of lard krw as Parcel 8 dos.:ibed 1n Sock 372 at Page 615 of Lica records of the Pitkin C-3i,ty C=ork and pnocceer; thcrze alerr3 the East line of aid ParCL1 B Vv following Eour (4) coarses; 1, North 18'M'09" East, 47,06 fmt; 2. thence mot-th 15,48,01" aat, 116.25 feet: 3. therm North 29'33'27" East, 63.55 foot: 4. tnCrOM North 12'15'49' :.Cat, 28.40 feet to a point m tha Scxrth line of a parm t of land deo✓il cd in Bock 222 at P.�30 9 of tha recactis of tha Pit}cin Ccunt7 Clark and REmrtfcr; thcsre along the South lire of :aid Por ' dCrib3d In Boat 222 at PaOe 9, South 73'42'20" Eye, 121.47 feet to the south st cornof said parcel: .Vxsce alma the East line Of said par NU th 19.04'05" East, 176.50 feet; thnnoa Scarth 77'22'41" Fast, 157.54 fee L-; thence South 57.34'58' East, 1,846.33 foet; throe South 57"34'58" East, 161.04 feet to the Pjint of BcglmLr3. 70=tER with a na:-exLlusive SIDDICrt for inane arta dress PurPO =s, voxe pnrlcilar:y deEct bog as follows: M easenent for arose slhratod in Section 22, 7tcnship 8 South, Range 88 West of ter 6tn PrirriPal Yerrdlan be-ing onto p3rtiorla.1y descxi.tnd as follows: Bcgirnixg at the Southeast mars of a pore l of lard k>own as Patrn1 A. desc'1bed in Dock 372 at Page 615 of the records of the Pitkin County Clerk end Retcrder; the North 62.39'00" 14est, 25.60 feet along the South bxentary of said Parcel A to the Seuthw_st acne of -said Parcel A; 000012 tl-rce Sarah 25'10'00" gest, 75.00 feet; Noone Nath 62" ?6'23" Last, 91.75 fact to to e„00th lire of a parce.1 of land recorded in Plat Bookty _ at Parge of the :ecord3 of tee Pr tkln Ccun Cleric and -7:7= Vtc'rce Narth 62.53'38" Wast, 30.00 feet wenn said South line trr the Point of Ie3irnirn; (Gentinuei) aryl 3 of Section 22, ' tip 8 RangeSruth, rp 88 of the 6th Principal Meridian, `rSng feet �,••,• in width and lyi ) feet on each side of the foll .ing degl, Abed e�> o ' ' 'Centerline: _JU �N >- Beginning at a point wherne the hhrth 1/4 comer of said Section 22 H j bears North 01.28"lo' west, 1,119.80 feet; �> o thence South 00'26146" Fast, 12.90 feet; Sao cr thence South 23.47'07" East, 38.32 feet; =N M thence South 05.48'46" East, 190.43 feet; le thcmce South 19.39'13" Wast, 96.01 feet; thence South 00.2614G" Fast, 397.86 feet; -'� IL ttrs;ce South 38.35'34•' Fast, 18.97 feet; V1 thence South 67.00116 East, 45.65 feet; � WK m thence South 78'20141 Fast, 77.40 feat; ttvr , South 90'00'0.•' East, 142.22 font to the point of ending, _am m said wl�rco id North 1/4 comerbears North bNorth 09'11116" Nast, 1,918.02 � to Z Feet; C4 CQ ;. I m and �M o A load easamnt- situate in Lots 1, 2 arts 3 of Section 22, Township 8 _\ m South, Range 88 West of the 6th Principal tMsidian, being 40 feat in =gj m width aid lying 20 feet on each side of the following described. �� to centerline: in m Cc ter, in Beginning at a point in the right-or-way Of Stats Highway No. 133 =at whence the north 1/4 Corner of said Section 22 bears North 03'45148" o in c West, 931.97 .feet; _(q n thence South 05.24115" Wast, 49.02 feet, - thence South C0.26146" East, 543.63 feet, said oa;rse baing parallel to and 20 feet C•astrrly of the kiest lime of said Int 2; om tes outh 21'41118" Fast, 85.61 feet;. therm South 23'47'07" East, 59.06 feet; 'thence South 05'48'46" East, 128.61 feet; ther=e South 21.53'10" Nast, 176.10 fact; thence South 00.26046" East, 398.00 feet; thence South 38.35'34" Fast, 18.97 feet; 'thence South 67.00'16" Fast, 45.65 feet; thence South 78.20141" East, 79.40 feet; theme north 90.00'00" Last, 161.58 feet; thaiw North 20'50'11" East, 16.76 feet; thescO North 22.33915" East, 160.79 feet; thence North 24'17'24" Fast, 286.36 feet; rn ttlerNorth 24'36110" East, 354.39 feet; thence North 21'04'10" East, 240.04 feet; thence North 25'10'00" East, 280.00 feet; thence North 27'14149" East, 24,59 foet; thence North 25'10'00" Fast 260.63 feet; then;oa North 24.11'00" Fast 366.16 feat to the point of ereing whence said North 1/4 mars bears North 86.03'05" West, 1140.24 feet-; and An a0cess easmmt Ming 40.00 feet in width and lying 20 feet on each side of the following desaibod oentarlino. Beginning at a point whence the North 1/4 corner of Section 22, owrllh 82 8 South, trt Nga 88 West of the 6th Principal Varidian bears bltit 02.50'14" West, 1,098.68 feet; thence South 69'00'00" East, 201.26 feet; them South 02.00'00" East, 107.92 feet; t M2599 B-784 P-702- 06/227/95 10:40A PC 3 OF 3 388691 B-803 P-520 12/29/95 02:50P PC 3 OF 3 000013 Bill & Jo Ellen My* l/- py 316 N. Thomas Rd. Carbondale, Colorado 81623 970.963.5721 000014 EAST ELEVATION V4". 110.1 WEST ELEVATION 1/4". 1W 000015 UPPER RIDGE _ -II IIAW T.O. LO F 0-L/4" T.O. PLATE -1® 1/4_LOFT FLO( 00'-0" Lo SLAB 19�-b^ G_RgpE Y NORTH ELEVATION 1/4". 1'0" a 12 /—� 13 �O SOUTH ELEVATION 1/4"• 1'0" } ryngg pe„ VOO C) C _ REVISIONS cuyysFa HJ.J' F I PFR K!N H fODLNE MU99 THK DRAWN: THK cNccFFo: E � m 0 � R � N 199y m m SHM A.1 A.3 000016 e SNEU A.'4 36.814 AC f/— BUILDING ENVELOPE FOR C.4REFfIXING D#ELI,CNC UNIT/ IRRIG.4FIOXV BOLDING POND 0.9.2 ACRES PLAN C TEE INSTALLED TO lBLE FROM MANHOLE 6 IN, MAX. BACKFILL OVER OPENING COVER OF MANHOLE FLUID TRANSFER SECTION NOTIFY ENGINEEROF HIGH NWATER TABLE ORF LINE F�ONNNIIONS 700 TANK. TANK SEPTIC TANK DETAIL NOT TO SCALE PPAYIR SYSTEHTF\ _ I -_ II CROSS HATCH REPRESENTS DITCH & POND SETBACK AREAS LEGEND AND NOTES i➢Ju' WWI W LS..110 0 ry rvn � 4 W u, 44su B ¢T N REMR Ni ENVEIfPE Ctli�ER -EpiE � N[M➢ —Onw LENiEPo.IIE a 5CAL-E; I" -- 200' 50.0' IRRIGATION DITCH SETBACK v 09 /0 I I 8 � I I I I I I I I I I I I I I \ I I \ \ DITCH S€TBAOv\ \\ \ \ \\ ` SEP\\TIC LINES 5\\PORT CONWRETl \ DI�TRIBU TION BOX \ \ \ JFIL TRA `AOR ARRAY \\ INFILTRATION BED \ \ INSTAL. INSPECTION \` PORTS @ ALL 4 CORNERS \ \ \ NOTE: WATERLINE CROSSINGS REQUIRE THAT THE DRINKING WATER OR WASTEWATER PIPE BE ENCASED FOR AT LEAST TEN (10) FEET OF EACH SIDE OF THE CROSSING OR PLACE WHERE COMPONENTS ARE CLOSER THAN TEN (10') FEET. PIPE OF SCHEDULE 40 RATING OR BETTER MUST BE USED, OF SUFFICIENT DIAMETER TO EASILY SLIDE OVER AND COMPLETELY ENCASE THE LINE. RIGID END CAPS OF AT LEAST SCHEDULE 40 RATING MUST BE GLUED OR SECURED IN A WATER -TIGHT FASHION TO THE ENDS OF THE ENCASEEMENT PIPE. THERE MUST BE A HOLE OF SUFFICIENT SIZE TO ACCOMMODATE THE PIPE IN THE LOWERMOST SECTION OF THE RIGED CAP SO THAT THE CONVEYANCE PIPE RESTS ON THE BOTTOM OF THE ENCASEMENT PIPE. THE AREA IN WHICH THE PIPE PASSES THROUGH THE ENDCAPS MUST BE SEALED WITH AN APPROVED UNDERGROUND SEALANT COMPATIBLE WITH THE PIPING USED. 1+� NATiRAL BACKFILL �Zv VAS%'i' A/SAA//AA//AA/ �VA /VA/vV�VA/VA�VA/VA VEVA/VA/VA/VA/ ; VA,/ z ///�X\ X� //A///A//A /�X j g Q pOOG'O( ��,o cr cO�G'O a O off' °a 'O'.c o A'G'O a Oa {n cO O �J0a °0vO 000 °�'OoI_��04O� �O(D' C) aoQ L)o OOQQO��C o°OG�a �'V QCo� °o�U� N ANDEEXET riEE�N� SHALL BE _ _ - _ - -__ aUUO a° Oo O �, DOC-�. <�� oo 0•OO° Oo�O�o�OO�'��O WITHIN i IN. OF TOP OF TANK 0•� O"Q �'� 00 G TYPICAL GRAVELS BOTTOM OF BED TO BE FT SECTION "A" - TYPICAL INFILTRATION BED PLACED ON GRAVELS NOT LESS THAN NOT TO SCALE (QTY MAY VARY) 9 INCHES OR MORE NOT AN 14. INFILTRATOR UNIT NATURAL BACKFILL - 0aG -0G THIS DRAWING SHOWS ALL EXISTING WELLS WITHIN SETBACK -- a 'cam - v `. X00 DISTANCES (INCLUDING ON SURROUNDING PROPERTIES), CONTOUR INTERVALS, --\:\ ALL PROPOSED AND EXISTING BUILDINGS, PROPERTY LINES, DITCHES, SLOPES OF GREATER THAN 157, WATER LINES, SPRINKLER SYSTEMS, SPRINGS, SUCTION SECTION "B" INFILTRATION BED (IRRIGATION) LINES, DRINKING WATER CISTERNS, DRAIN TILES, IRRIGATION DITCHES, PLACED ON GRAVELS \\ NOT TO LAKES, PONDS, WATER COURSES, STREAMS, FLOODPLAINS, FLOODWAYS, DRY GULCHES, OR EXISTING SEPTIC SYSTEMS, AND ALL SUCH FEATURES ON NEIGHBORING PROPERTIES WITHIN SETBACKS. fg \ \ 9v x \ \ LINE BEAM MUANCE \ \ \ L 1 N 35.UME MR, \ L 2 N 5&04'35'V 9026' \ \ \ L 3 N 32W'59E B6V \ \ L 4 N 4MW47-E 3629' \ \ L 5 N 626 &E 109.44' \ \ \ L 6 L 7 N 1&M'9'E N 19W'09'E SW 5' EAU, � \ L B S 0&56'33E 1.90' \ L 9 N 1004'P3'E 47.06' L 10 L N N L%Q%E N 2&33'3PE 11625' MY L 12 N ENI 49N 2640' 36.814 AC f/— BUILDING ENVELOPE FOR C.4REFfIXING D#ELI,CNC UNIT/ IRRIG.4FIOXV BOLDING POND 0.9.2 ACRES PLAN C TEE INSTALLED TO lBLE FROM MANHOLE 6 IN, MAX. BACKFILL OVER OPENING COVER OF MANHOLE FLUID TRANSFER SECTION NOTIFY ENGINEEROF HIGH NWATER TABLE ORF LINE F�ONNNIIONS 700 TANK. TANK SEPTIC TANK DETAIL NOT TO SCALE PPAYIR SYSTEHTF\ _ I -_ II CROSS HATCH REPRESENTS DITCH & POND SETBACK AREAS LEGEND AND NOTES i➢Ju' WWI W LS..110 0 ry rvn � 4 W u, 44su B ¢T N REMR Ni ENVEIfPE Ctli�ER -EpiE � N[M➢ —Onw LENiEPo.IIE a 5CAL-E; I" -- 200' 50.0' IRRIGATION DITCH SETBACK v 09 /0 I I 8 � I I I I I I I I I I I I I I \ I I \ \ DITCH S€TBAOv\ \\ \ \ \\ ` SEP\\TIC LINES 5\\PORT CONWRETl \ DI�TRIBU TION BOX \ \ \ JFIL TRA `AOR ARRAY \\ INFILTRATION BED \ \ INSTAL. INSPECTION \` PORTS @ ALL 4 CORNERS \ \ \ NOTE: WATERLINE CROSSINGS REQUIRE THAT THE DRINKING WATER OR WASTEWATER PIPE BE ENCASED FOR AT LEAST TEN (10) FEET OF EACH SIDE OF THE CROSSING OR PLACE WHERE COMPONENTS ARE CLOSER THAN TEN (10') FEET. PIPE OF SCHEDULE 40 RATING OR BETTER MUST BE USED, OF SUFFICIENT DIAMETER TO EASILY SLIDE OVER AND COMPLETELY ENCASE THE LINE. RIGID END CAPS OF AT LEAST SCHEDULE 40 RATING MUST BE GLUED OR SECURED IN A WATER -TIGHT FASHION TO THE ENDS OF THE ENCASEEMENT PIPE. THERE MUST BE A HOLE OF SUFFICIENT SIZE TO ACCOMMODATE THE PIPE IN THE LOWERMOST SECTION OF THE RIGED CAP SO THAT THE CONVEYANCE PIPE RESTS ON THE BOTTOM OF THE ENCASEMENT PIPE. THE AREA IN WHICH THE PIPE PASSES THROUGH THE ENDCAPS MUST BE SEALED WITH AN APPROVED UNDERGROUND SEALANT COMPATIBLE WITH THE PIPING USED. 1+� NATiRAL BACKFILL �Zv VAS%'i' A/SAA//AA//AA/ �VA /VA/vV�VA/VA�VA/VA VEVA/VA/VA/VA/ ; VA,/ z ///�X\ X� //A///A//A /�X j g Q pOOG'O( ��,o cr cO�G'O a O off' °a 'O'.c o A'G'O a Oa {n cO O �J0a °0vO 000 °�'OoI_��04O� �O(D' C) aoQ L)o OOQQO��C o°OG�a �'V QCo� °o�U� N ANDEEXET riEE�N� SHALL BE _ _ - _ - -__ aUUO a° Oo O �, DOC-�. <�� oo 0•OO° Oo�O�o�OO�'��O WITHIN i IN. OF TOP OF TANK 0•� O"Q �'� 00 G TYPICAL GRAVELS BOTTOM OF BED TO BE FT SECTION "A" - TYPICAL INFILTRATION BED PLACED ON GRAVELS NOT LESS THAN NOT TO SCALE (QTY MAY VARY) 9 INCHES OR MORE NOT AN 14. INFILTRATOR UNIT NATURAL BACKFILL - 0aG -0G 'cam - v `. X00 900 GRAVELS BOT -OM OFBED TO BE SECTION "B" INFILTRATION BED PLACED ON GRAVELS NOT TO SCALE (QTY MAY VARY) 0 i\ WATER -LINE CLEANOUT S " =10' A. CALCULATIONS 1. PERCOLATION RATE = 23 MPI AVG. (H.P. GEOTECH JOB NO. 199 872) 2. DESIGN FLOW CARETAKER= 2 BEDROOMS X 2 X 75 X 1.75 = 525 GALLONS PER DAY (-2,000 SF RESIDENCE) 3. REQUIRED SEPTIC TANK CAPACITY = 525 X 1.25 = 657 GALLONS USE ONE - 1,000 GALLON TWO COMPARTMENT CONCRETE SEPTIC TANK 4. ABSORBTION BED REQUIRED = A= (525/5) *231/2=504 SF DEDUCT 30% FOR INFILTRATOR BED = 353 SF 5. INFILTRATOR BED INSTALLATION: 353 SQ. FT./ 15.5 SOFT PER UNIT = 23 UNITI Iii USE 4 UNIT X E UNIT INFILTRATOR ARFAY 124 PROviDED) 6. WELL SETBACK DISTANCE 100 + 8 * ((525-1000)/100) = 100 FEES 7. DITCH, STREAM AND POND SETBACK DISTANCE 50 + 8 * ((525-1000)/100) = 50 FEET B. WATERLINE SETBACK DISTANCE 10 FEET TO TANK, 25 FEET TO FIELD B. GENERAL NOTES 1. THE INFILTRATOR BED SHALL BE LEVEL (+/- 0.1 INCHES), ON NATURAL GROUND (NOT IN FILL AND MUST PROVIDE POSITIVE DRAINAGE AWAY FROM THE BED, 2. THE SEPTIC TANK SHALL BE LOCATED AT LEAST FIVE FEET AWAY FROM THE RESIDENCE 3. THE PIPE FROM THE RESIDENCE TO THE TANK MUST BE INSTALLED AS FOLLOWS: THE PIPE MUST BE INSTALLED STRAIGHT IN ALIGNMENT AND GRADE, IF A CHANGE IN ALIGNMENT OR GRADE IS NECESSARY, A CLEANOUT WILL BE REQUIRED AT THE CHANGE. THE MINIMUM GRADE OF THE PIPE MUST BE 1/4" PER FOOT. THE PIPE MUST BE A MINIMUM OF ASTM 3034 PVC PIPE, A MINIMUM OF i CLEANOUT SHALL BE INSTALLED AT THE LOCATION WHERE THE PIPE LEAVES THE RESIDENCE. THE PIPE SHALL BE A MINIMUM OF 4" IN DIAMETER. 4. THE PIPE FROM THE SEPTIC TANK TO THE INFILTRATOR BED SYSTEM MUST BE INSTALLED AS FOLLOWS: THE MINIMUM SLOPE OF THE LINE MUST BE 1/4" PER FOOT. THE PIPE SHALL BE A MINIMUM OF ASTM 3034 PVC PIPE. THE PIPE SHALL BE A MINIMUM OF 4" IN DIAMETER. 5. USE RISERS TO BRING THE SEPTIC TANK ACCESS WITHIN 6" OF FINAL GRADE, 6. ALL MATERIALS, INSTALLATION PRACTICES AND SETBACK REQUIREMENTS SHALL COMPLY WITH PITKIN COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS. 7. INFILTRATOR COMPONENTS TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS, 8. PLACE DISTRIBUTION BOX AND DISTRIBUTION PIPING ON 3/4" SCREENED ROCK. SEAL ALL PIPES ENTERING DISTRIBUTION BOX WITH WATERPROOF MATERIAL 9. PROVIDE INSPECTION PORTS AT ALL 4 CORNERS 00003i q,►,DO Rf�j �,, 'cPPoO^?Q1pOp��. O �I9q` f f. wen COf'YRIGIfi 0 �GX ® la �i DRAWN �Y Of' � O a 0 Z O DArt 11/2//99 RPVl51ON5 SGN.P f�5 SnOWN L)PAYING I5U51'LAN N07 -f-'5 and OETiAIL5 5acer 0 PORT CONCRETE '-)-'iSTRIBUTION BOX 6 INFILTRATOR ARRAY INFILTRATION BED INSPECTION PORTS. @ ALL COR"�EF`� CLEANOUT 111J4 �SEPTIC LINES M 00 N O 00 5GAL-E 1" _ f5' 0000�� -_�rt,�.�u fir;;;'^�•, COPYR�GIfI" .� P _-- rl)� DRi{NN HY j t O � � O =;/o RCV/5iC1N5 /5 SnOwN 'FAJ DRAWlN'G �rccr I