Permit # 99102
Aspen/Pitkin Environmental Health Department
Permit for an Individual Sewage Disposal System
130 S. Galena St. Aspen, Colorado 81611
Phone 970-920-5070 / FAX 970-920-5074
Parcel ID # 2463-221-00-020
Type of permit New( x ) Repair( ) Addition to House( )
Name of Owner William
Street Address 316 N. Thomas Rd, Carbondale
Properly legal description
Size of lot 37 acres
Water source private well
Total square footage of the house
# of bedrooms in house If of offices, lofts & similar sized rooms in house
Caretaker unit yes Total square footage of the caretaker unit 400 sq
feet
# of bedrooms in caretaker unit 0 # of offices, lofts & similar sized rooms in caretaker unit
Designed for what # rooms (list) 2 (two)
Designed by
Mailing Address
Perc rate 23
Permit information
Dave Powell, Timberline En
PO Box 631, Carbondale, CO 81623
Profile hole depth 8ft Depth to groundwater or bedrock
Septic tank capacity 1000 gallons Absorption area 353 square feet
Comments
unknown
Septic permit approved per compliance with the engineer design and specifications dated November 21,1999. Any
changes must be approved by this department and the design engineer prior to them being made.
Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin
County ISDS regulations. This department does not endorse any brand of products.
System designed for the caretaker unit includes a 1000 gallon tank and 24 Infiltrator Units (6x4) in a bed
configuration. Setback from irrigation ditch and must be at least 50 feet.
Horse traffic over the absorption bed should be kept to a minimum.
Permit approved by: 6216 LOLL _ Date:I�kq�—
Plans and specifications of the proposed individual sewage disposal system have been reviewed and are considered
satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin
County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was
issued unless system construction has commenced or an extension has been approved in writing by the Department.
As -built drawings must be included with this permit before the final approval will be issued.
Installer: 0Ur7 �
O�OT 1 ' y�11 j
ma nspection approval: h � n fl dL Date:
OCT -25',99 MON 02:51 PM ASPEIITKIN ENV HEALTH FAX:970 920 5074
ASPEN 1 l KIN ENVIRONMENTAL HEALTH DEPAR I MENT
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM
130 S. Galena St., Aspen Colorado 81611
Phone 970-920-5070/Fax 970-920-5074
WUF
Name of OWNER / r/r/i�yEjj�C /
Owner ,/, //zi/s Mailing Address _0,16 — r AV �bp? , 5216Z3
Business Phone: Home Phone: — 96,? S -7,Z/ 063 /678
Primary Contact Person (all communication regarding this permit wi0 go through this person)
Name
Contact Mailing Address
Business Phone 463
S// -
Cell
// -
Cell Phone
eU gi<
3 /6'78
rarcei to a tavanacte from assessors orrice
at 920.5160 or at www.aspen.comlas/sissor� �- 6 3 - 2 / - O O - D Z- O
Street address of property 3/6 — A/o, lo�d _CQLZ41
Legal Description: Lot _ ,Block ,Filing ,Subdivision
Size of lot. -37-t acres.
Type of proposed structure: CDL/ Size of 3Idg. envelope: D.
Total square feet of house # of bedrooms in house 4112w-
9 of offices, lofts B similar sized rooms in house
Caretaker Unit: Attached( ) Detached( //) Total area(sq. R.) of caretaker tnfit _
# of bedrooms in caretaker unit O n e- X of offices. lofts and similar size rooms of caretaker unit
Permit is for: New Home ( ) Repatr due to failure ( ) Remodel/Addhion ( !f) Emergency use ( )
Water. Private wen ( Spring ( ) Stream ( ) Community/Public Water System ( )
If community system: Name of system
The fee for a ISDS application is $330 for a permit that takes 6 hours or less for the department to approve. If approval takes
longer than 6 hours, a rate of $55 per tour will be charged. The maximum fee is 51000. The basic fee of $330 is due at the bine
of application, The remaindw, if any, will be due in two stages: first, at the time of issuance of the ISDS permit; second. before
final approval of the ISDS permit.
Application for an individual sewage disposal syst- - is hereby submitted. I hereby certify that the above information is true and
accurate and that I have provided true and accur 3 information on locations of all existing and proposed wells, contour
intervals, buildings. property lines, ditches, 310pds. waterlines, springs, suction or irrigation lines, drinking water cisterns, drain
tiles. imgation ditches, lakes, water courses, streams, floodplams, dry gulches, and existing septic systems. I hereby certify
that any such features riot shown On attached site map are not present. Issuance of the pennil does not imply the approval of
any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all
approvals and permits have been obtained.
The Aspen/Pitkin Environmental Health Department. Pdkm County and employees of these agencies will be held harmless
should the individual sewage disposal system fad or malfunction. The permit to construct is issued on information submitted by
the applicant or hlslher representatives. The owner assumes full responsibility in case of failure of the system.
Signature of applicant
Received by
000002
Date /a/g.
Receipt # j 3 Date
1 11�1IG31=.11 .11. IME IF: .\( fl, 1011: 0
STRUCTI.IRAII./CEVU, IENGENIE]ERIING ♦ CONTRACTIING ♦ CERTMED`)uN ERGY DESIGN PROIFIESSIIONAIL
August 8, 2000
Pitkin County Environmental Health
Attn: Nancy MacKenzie �7
130 South Galena
Aspen, Colorado 81611 AUG 1 0 2000
Re: LSDS Installation ENVIRONMENTAL HEALTH
Permit # 99102 ASPEN / PITYJN
Myers Residence
0316 North Thomas Road
Carbondale, CO 81623
Dear Nancy:
The installation of the ISDS for the above residence has been completed and has been installed
in accordance with applicable county specifications and the approved plan. Enclosed is the as -
built drawing for the system.
If you have any questions, please call me at 963 -9869 -
Sin �rely�,
David A. Powell, PE
Reg. No. 25851
cc: Myers Residence
0316 North Thomas Road
Carbondale, CO 81623
000003
P.O. BOX 631 CARBONDALE, CO. 81623 PHONE 970 963 9869 / FAX 970 963 9003
July 24, 2000
To:
Pei A do,
Yi WM
1
RE:
CC:
Dear
Prrtax COUNTY
ENVIRONMENTAL HEALTH DEPARTMENT
This letter is to advise you the we have not been able to final the Individual Septic Disposal System
(ISDS) permit for the above stated residence/property.
It is of utmost importance for the Environmental Health Officer to final all ISDS permits once proper
installation and required inspections are complete. We cannot sign the Certificate of Occupancy for this
property without the "As Built" letter.
It is mandatory that this, office receive an "As Built" letter from the engineer who designed the system.
An "As Built" letter will confirm that they observed the installation of the system as designed. Any
changes to the system must be noted in the "As Built" letter or by a new set of plans.
This office must receive the "As Built" letter from the engineer no later th 15 2000.
Please contact me with any questions. Thank you, in advance, for your help and co-operation in this
matter.
Sincerely,
00
Madelyn Blumenthal
Pitkin County Environmental Health
46
000004
130 SOuTH GALENA STREET • ASPEN, COLORADO 81611-1975 - PHONE 970.920.5070 - FAx 970.9205074
w .npmgov.com/ehnm/cowry/indexJitml
FMW wRe WPepe
November 15, 1999
Bill Meyers
316 North Thomas Road
Hep,O Pawlak Geotechnical, Inc.
5020 County Road 154
Glenwood Springs, Colorado 81601
Phone: 970.945-7988
Fax: 970-945-8454
hpgeo@hpgeotech.com
Carbondale, Colorado 81623 Job No. 199 872
Subject: Percolation Testing, Proposed Art Studio, 316 North Thomas Road,
South of Carbondale, Pitkin County, Colorado
Dear Mr. Meyers:
As requested, we have conducted percolation testing at the subject site to evaluate the
feasibility of an infiltration septic disposal system. The results of our work are
presented in this report. The work was done in accordance with our agreement for
Professional Services to you dated November 5, 1999.
A profile pit and three shallow backhoe pits were excavated on November 5, 1999. The
septic area is located to the southeast of the two proposed buildings as shown on Fig.
1. Percolation test holes (about 12 inches in diameter and 12 inches deep) had been dug
in the bottom of backhoe pits and soaked by the client one day prior to testing. The
soils exposed in the percolation test holes and profile pit consist of about 3 feet of
topsoil overlying silty gravel and cobbles with occasional boulders to the profile pit
depth of 8 feet.. No free water was encountered in the pits and the subsoils were
slightly moist to moist. The percolation holes appeared to be in topsoil. The holes
were deepened into the underlying gravels and re -soaked on November 7, 1999.
Percolation tests were performed in the percolation test holes on November 8, 1999 by
a representative of Hepworth-Pawlak Geotechnical, Inc. The percolation test results are
presented on Table I. The percolation test results indicate an infiltration rate between
13 and 36 minutes with an average of 23 minutes per inch. Based on the subsurface
conditions encountered and percolation test results, a conventional infiltration septic
disposal system appears feasible at the tested location.
000005
C
C
Bill Meyers
November 15, 1999
Page 2
u
If you have any questions or if we can be of further assistance, please call our office.
Sincerely,
HEPWORTH - PAWLAK
Jordy Z. Adamson, Jr. .E.
Rev. By: DEH
JZA/sd
attachments
cc:
000006
INC.
RE
iv 2970 � `•
FSS �N A���G�
Timberline Engineering - Attn: Dave Powell
A?PROXIMATE SCALE
t"=50'
TO
T NOMAS Rn . _
199 872 HEPWORTH - PAWLAKHNICALI LOCATION OF PROFILE PIT AND I Fig. 1 I
GEOTEC, INC. PERCOLATION TEST HOLES
000007
HEPWORTH-PAWLAK GEOTECHNICAL,
TABLE I
PERCOLATION TEST RESULTS
HOLE NO.
HOLE DEPTH
(INCHES)
LENGTH OF
INTERVAL
(MIN)
WATER DEPTH
AT START OF
INTERVAL
(INCHES)
WATER DEPTH
AT END OF
INTERVAL
(INCHES)
DROP IN
WATER
LEVEL
(INCHES)
AVERAGE
PERCOLATION
RATE
(MIN./INCH)
P-1
50
15
water added
7
51/4
1 3/4
20
5 1/4
4
1 14
7 1/4
6 1/4
1
6 1/4
5 112
3/4
5 1/2
43/4
3/4
43/4
4
3/4
P-2
53
15
8
7
1
36
7
6 1/2
1/2
6 1/2
5 3l4
3/4
53/4
5 1/4
1/2
5 1/4
4 3/4
1/2
43/4
41/2
1/4
P-3
52
15
water added
water added
7
5 1/4
1 3/4
13
51/4
3 1/2
1 3/4
7 3/4
6
1 3/4
7 1/2
6 1/4
1 1/4
6 1/4
5
1 1/4
5
4
1
Note: Percolation test holes were hand dug and soaked by the client on November 7, 1999. Percolation tests were conducted
on November £, 1999. The average percolation rate was based on the last three readings of each test.
•
119111111!1 111111 IIII 111111 IIII I. _;l III IIIII IIII IIII
435781 09/22/1999 12:50P RESOLiTI onvIs SILVI
1 of 5 R 0.00 0 0.00 N 0.00 PITKIN COUNTY CO
RESOLUTION OF THE BOARD OF COUNTY COMMISSIONERS OF PITKIN COUNTY,
COLORADO, GRANTING A MINOR AMENDMENT TO A BUILDING ENVELOPE AND
SPECIAL REVIEW APPROVAL OF A DETACHED CARETAKER DWELLING UNIT AND
MINOR BUILDING ENVELOPE EXPANSION ON THE MYERS PROPERTY
Resolution No. 99-11-53
RECITALS
I. Bill Myers, lherea@er "applicant " has applied to the Board of County Commissioners of Pitkin
County, Colorado, hereafter, "Board," for a special review approval of detached caretaker dwelling
unit and a minor building envelope expansion.
2. The Property, described in Exhibit A, is located at 3 16 N. Thomas Rd.
3. The lot is 37 acres and zoned RS -30.
4. The Board heard this application at a public hearing on August 25, 1999 at which time evidence and
testimony were presented with respect to the application.
5. The Board finds that the application complies with the applicable Code Sections.
NOW, THEREFORE, BE IT RESOLVED by the Board that it does hereby grant approval of the
Myers detached caretaker dwelling unit and minor building envelope expansion subject to the following
conditions which shall run with the land and be binding on all successor in interest:
1. The applicant shall adhere to all material representations made during the application process.
2. A caretaker dwelling unit deed restriction shall be recorded with the Housing Office prior to issuance
of a building permit for the CDU. The applicant shall comply with all Housing Authority guidelines
for CDUs. Floor plans of the proposed unit calculating the net livable square footage shall be
submitted to and approved by the Housing Office prior to building permit approval.
3. There shall be one off-street parking space on the property for each bedroom in the CDU.
4. Prior to issuance of any building permits the applicant shall obtain approval of an ISDS permit from
the Environmental Health Department. The septic system must comply with all minimum horizontal
setback requirements between its components and physical features. A qualified professional
engineer must design the system. The septic system shall be located within the building envelope.
5. No building permits for residential use shall be submitted until the intersection of Highway 133 and
Thomas Road has been improved to ensure the safety of the traveling public to the satisfaction of the
Colorado Department of Transportation (CDOT) and the County Engineer. If the owners of the
property illegally construct the caretaker unit, the use will be revoked and no longer allowed on the
property.
6. Prior to the submittal of building permits, the Applicant shall be in compliance with Resolution PZ
91-33 and BOCC Resolution 91-83.
Y
1 MI
q9 -asp O 111111111111111111 "l 111111 IT 11111111111111111VIS 11 IN
LVI
2 of 5 R 0.00 D 0.00 N 0.00 PITKIN COUNTY CO
Myers Caretaker Dwelling Unit
Page 2 of 3
7. The Applicant shall comply with the following wildfire mitigation conditions with regard to
development in the lower building envelope (the "barn envelope"):
A. Applicant shall establish and maintain a ten foot perimeter around all structures in the barn
envelope where vegetation is no taller than six inches. Woody vegetation shall not be
planted nor shall flammable material be stored within this perimeter.
B. A ten foot spacing shall be maintained between the outside edges of the crowns of all trees
(including future landscaping) for a thirty foot perimeter around the caretaker
unit/agricultural structure buildings complex.
C. Roots shall have a Class A, non-combustible roof system. Flat roofs (up to a 4:12 pitch)
and wood shake shingles shall be prohibited.
D. Vents shall be screened with corrosive resistant wire mesh with mesh 'A inch maximum.
E. All development associated with the proposed affordable housing unit shall ineet all code
requirements of the Carbondale and Rural Fire Protection District.
F. The proposed pond shall be accessible to Fire Department Vehicles in the event of a wildfire.
G. Roofs and gutters shall be kept clear of debris.
H. Yards shall be kept clear of all litter, slash, and flammable debris.
L All flammable materials shall be stored on a parallel contour a minimum of 15' from any
structures.
J. Firewood shall be stacked on a parallel contour a minimum of 15 feet away from any
structure.
K. Propane tanks shall be installed according to NFPA 48 standards and on a contour away from
the structure with standard defensible space vegetation mitigation around any above-
ground tank. Any wood enclosures around the tank shall be constructed with materials
approved for 2 hour fire -resistive construction on the exterior side of the walls.
L. Fences shall be kept clear of brush and debris.
M. Wood fences shall not be connected to the structure.
N. Fuel tanks shall be installed underground with an approved container.
O. Each structure shall have a minimum of one 10 Ib. ABC fire extinguisher.
P. Addresses shall be clearly marked and visible with minimum 2" non-combustible letters and
shall be clearly visible at the primary point of access from the public or common access
road and installed on a non-combustible post.
Q. Any outbuildings or additional buildings shall adhere to the same standards as structures.
8. No development, including grading, landscaping, vegetation removal or disturbance, and septic
system shall occur outside of the approved access and building envelope except as may be necessary
to implement the wildfire mitigation measures required elsewhere in this approval.
9. The Applicant shall adhere to all material representations made in the application and public
meetings.
10. The vested rights established pursuant to this approval shall expire on August 25, 2002.
000010
435781 09/22/1999 12:50P RESOLUTI DAVIS SILVI
3 of 5 R 0.00 D 0.00 N 0.00 PITKIN COUNTY CO
Myers Caretaker Dwelling Unit
Page 3 of 3
NOTICE OF PUBLIC HEARING PUBLISHED IN THE ASPEN TIMES ON JULY 24,1999.
APPROVED AND ADOPTED ON THE 25TH DAY OF AUGUST, 1999.
NOT)CE OF STABLISHMENT OF A VESTED RIGHT published in Aspen Times Weekly on the
J5�dayor.: rirj` , 1999.
ATTEST:
L , ee ean,
Deputy Clerk and Recorder
APPROVED AS TO FORM
John Ely,
Coue ttorney
Case #P80-99
Parcel I.D. # 2645-143-00-017
carevm109/01/99
000011
BOARD OF COUNTY COMMISSIONERS
OF PITKIN COUNTY, COLORADO
APPROVED AS TO CONTENT
"n,
Cindy Houben
Community Development Director
" Leslie 1. Lamo t
Chair,gy
�^i %�
a
1 I.C ,
APPROVED AS TO CONTENT
"n,
Cindy Houben
Community Development Director
.342699 B-784 P-701 06/27/95 10:40A PG 2 OF 3
J - Exhibit "A"
388690 B-803 P-519 12/29/9� 02;
N H .,�0P PG 2 OF*3
-N Z
M f�
®au 71n land rePcztad to in the Ca,,itlent is ecwsr>ng the larxi in the State of
Z Colorafb, Cotarty of Pi-. ki, , de,=ibed as folla+s:
j F A Parcel of land situatod in Section 22 and Section 23, 4txttsh3 e
South, Barge Bo '.rest of t. -e 6th Principal Neridlan, b Log mc¢a p
®N Particularly de_sclbed as follows:
Sa#ryring at a point -frrr:m thn North 1/4 correr of said SaoUm 22
ecce 4. t9 Josars Morth 65" 25' 40" Wast, 3.413.28 feet;
tttttttttt•B�j = trrnm South 35'11'11" 'test, 673.42 feet to a mint m the forth Lira
� CD of thO Pitt n rcu tr^a-- �aRamcLjptlon to, 254931 of the ztamrt'a
-m trrzn, alorg the North lire of said Psxptim No. 254931 North
62.18'00" West, 663.86 feet alarl said K7rth Nim:
thence Norh 35' 11'33" East, 23.32 feet to a fence comer;
CD thace North 58.04'35" West, 90.26 feet al
crq ®No t`Iarce North 64.15'26" lees t, 145.48 fent al a canoe;
eg a fero,;
=mo theme North 62'53'38':, 11295.20 feet alar3 a fence to a hint on
m cc the Ear6Crly lira of a ParcelBook of lard krsa n a, 1`arer:l A, ear-...-.. In
� Recorder;
ttttttttttw Sat FaOe 613 01 Via co=rds of t1r Pitkin County Cork aryl
o- rp
=tn ° _thence, aloYj tin East line cf said ?arcx•1 A the following live (5)
-vv
I. North 32"11'59" East, 8.60 feet;
2. theme North 42'08'47" East, 36.29 feet:
3. thence. North 62' 52' 28' East, 109.44 fent:
4. UW100 North 36'13'16' East, 123.14 feet:
5. the oO t+octh 18'44'09" East. 55.00 feet to tin Sorthaast cor*+er of
pcel of Sind kr as Parcel C desrsionl in 0.vk 459 at P
tarhe records of VY! Pitkin County .Clerk and launder; °g° 298 of
then almcl tln Fast lira of Will ParQ1.C, Nbr",;h 18'44'09" Fast,
24.57 feet;
the South 89'56'33" Fist, 1.90 feet to ten Swtheast corgi of a
pazoal of lard krw as Parcel 8 dos.:ibed 1n Sock 372 at Page 615 of
Lica records of the Pitkin C-3i,ty C=ork and pnocceer;
thcrze alerr3 the East line of aid ParCL1 B Vv following Eour (4)
coarses;
1, North 18'M'09" East, 47,06 fmt;
2. thence mot-th 15,48,01" aat, 116.25 feet:
3. therm North 29'33'27" East, 63.55 foot:
4. tnCrOM North 12'15'49' :.Cat, 28.40 feet to a point m tha Scxrth
line of a parm t of land deo✓il cd in Bock 222 at P.�30 9 of tha
recactis of tha Pit}cin Ccunt7 Clark and REmrtfcr;
thcsre along the South lire of :aid Por ' dCrib3d In Boat 222 at
PaOe 9, South 73'42'20" Eye, 121.47 feet to the south st cornof
said parcel:
.Vxsce alma the East line Of said par NU th 19.04'05" East, 176.50
feet;
thnnoa Scarth 77'22'41" Fast, 157.54 fee L-;
thence South 57.34'58' East, 1,846.33 foet;
throe South 57"34'58" East, 161.04 feet to the Pjint of BcglmLr3.
70=tER with a na:-exLlusive SIDDICrt for inane arta dress
PurPO =s, voxe pnrlcilar:y deEct bog as follows:
M easenent for arose slhratod in Section 22, 7tcnship 8 South, Range
88 West of ter 6tn PrirriPal Yerrdlan be-ing onto p3rtiorla.1y
descxi.tnd as follows:
Bcgirnixg at the Southeast mars of a pore l of lard k>own as Patrn1
A. desc'1bed in Dock 372 at Page 615 of the records of the Pitkin
County Clerk end Retcrder;
the North 62.39'00" 14est, 25.60 feet along the South bxentary of
said Parcel A to the Seuthw_st acne of -said Parcel A;
000012 tl-rce Sarah 25'10'00" gest, 75.00 feet;
Noone Nath 62" ?6'23" Last, 91.75 fact to to e„00th lire of a parce.1
of land recorded in Plat Bookty _ at Parge of the :ecord3 of
tee Pr tkln Ccun Cleric and -7:7=
Vtc'rce Narth 62.53'38" Wast, 30.00 feet wenn said South line trr the
Point of Ie3irnirn;
(Gentinuei)
aryl 3 of Section 22, ' tip 8
RangeSruth, rp 88 of the 6th Principal Meridian, `rSng feet
�,••,• in width and lyi ) feet on each side of the foll .ing degl, Abed
e�> o ' ' 'Centerline:
_JU
�N
>- Beginning at a point wherne the hhrth 1/4 comer of said Section 22
H j bears North 01.28"lo' west, 1,119.80 feet;
�> o thence South 00'26146" Fast, 12.90 feet;
Sao cr thence South 23.47'07" East, 38.32 feet;
=N M thence South 05.48'46" East, 190.43 feet;
le
thcmce South 19.39'13" Wast, 96.01 feet;
thence South 00.2614G" Fast, 397.86 feet;
-'� IL
ttrs;ce South 38.35'34•' Fast, 18.97 feet;
V1 thence South 67.00116 East, 45.65 feet;
� WK m thence South 78'20141 Fast, 77.40 feat;
ttvr , South 90'00'0.•' East, 142.22 font to the point of ending,
_am
m said wl�rco id North 1/4 comerbears North bNorth 09'11116" Nast, 1,918.02
�
to Z Feet;
C4 CQ
;. I m and
�M o A load easamnt- situate in Lots 1, 2 arts 3 of Section 22, Township 8
_\ m South, Range 88 West of the 6th Principal tMsidian, being 40 feat in
=gj m width aid lying 20 feet on each side of the following described.
�� to centerline:
in
m Cc
ter,
in Beginning at a point in the right-or-way Of Stats Highway No. 133
=at whence the north 1/4 Corner of said Section 22 bears North 03'45148"
o in c West, 931.97 .feet;
_(q n thence South 05.24115" Wast, 49.02 feet, -
thence South C0.26146" East, 543.63 feet, said oa;rse baing parallel
to and 20 feet C•astrrly of the kiest lime of said Int 2;
om
tes outh 21'41118" Fast, 85.61 feet;.
therm South 23'47'07" East, 59.06 feet;
'thence South 05'48'46" East, 128.61 feet;
ther=e South 21.53'10" Nast, 176.10 fact;
thence South 00.26046" East, 398.00 feet;
thence South 38.35'34" Fast, 18.97 feet;
'thence South 67.00'16" Fast, 45.65 feet;
thence South 78.20141" East, 79.40 feet;
theme north 90.00'00" Last, 161.58 feet;
thaiw North 20'50'11" East, 16.76 feet;
thescO North 22.33915" East, 160.79 feet;
thence North 24'17'24" Fast, 286.36 feet;
rn
ttlerNorth 24'36110" East, 354.39 feet;
thence North 21'04'10" East, 240.04 feet;
thence North 25'10'00" East, 280.00 feet;
thence North 27'14149" East, 24,59 foet;
thence North 25'10'00" Fast 260.63 feet;
then;oa North 24.11'00" Fast 366.16 feat to the point of ereing whence
said North 1/4 mars bears North 86.03'05" West, 1140.24 feet-;
and
An a0cess easmmt Ming 40.00 feet in width and lying 20 feet on each
side of the following desaibod oentarlino.
Beginning at a point whence the North 1/4 corner of Section 22,
owrllh 82 8 South, trt
Nga 88 West of the 6th Principal Varidian bears
bltit 02.50'14" West, 1,098.68 feet;
thence South 69'00'00" East, 201.26 feet;
them South 02.00'00" East, 107.92 feet;
t
M2599 B-784 P-702- 06/227/95 10:40A PC 3 OF 3
388691 B-803 P-520 12/29/95 02:50P PC 3 OF 3
000013
Bill & Jo Ellen My* l/- py
316 N. Thomas Rd.
Carbondale, Colorado 81623
970.963.5721
000014
EAST ELEVATION
V4". 110.1
WEST ELEVATION
1/4". 1W
000015
UPPER RIDGE _
-II IIAW T.O. LO F
0-L/4" T.O. PLATE
-1® 1/4_LOFT FLO(
00'-0" Lo SLAB
19�-b^ G_RgpE
Y
NORTH ELEVATION
1/4". 1'0"
a 12 /—� 13
�O
SOUTH ELEVATION
1/4"• 1'0"
}
ryngg
pe„
VOO
C) C
_
REVISIONS
cuyysFa HJ.J' F
I PFR K!N H fODLNE
MU99 THK
DRAWN: THK
cNccFFo:
E
� m
0
� R �
N
199y m m
SHM
A.1 A.3
000016
e
SNEU
A.'4
36.814 AC f/—
BUILDING ENVELOPE FOR
C.4REFfIXING D#ELI,CNC UNIT/
IRRIG.4FIOXV BOLDING POND
0.9.2 ACRES
PLAN
C TEE INSTALLED TO
lBLE FROM MANHOLE
6 IN, MAX. BACKFILL OVER
OPENING COVER OF MANHOLE
FLUID
TRANSFER
SECTION
NOTIFY ENGINEEROF HIGH NWATER TABLE
ORF LINE F�ONNNIIONS 700 TANK. TANK
SEPTIC TANK DETAIL
NOT TO SCALE
PPAYIR SYSTEHTF\
_ I
-_ II
CROSS HATCH REPRESENTS
DITCH & POND SETBACK AREAS
LEGEND AND NOTES
i➢Ju' WWI W LS..110
0 ry rvn � 4 W u, 44su
B ¢T N REMR Ni ENVEIfPE Ctli�ER
-EpiE � N[M➢
—Onw LENiEPo.IIE a
5CAL-E; I" -- 200'
50.0'
IRRIGATION DITCH SETBACK
v 09
/0 I I
8 � I
I I
I
I I I
I I
I I
I I I \
I I \
\ DITCH S€TBAOv\ \\ \ \
\\ ` SEP\\TIC LINES
5\\PORT CONWRETl \
DI�TRIBU TION BOX \ \ \
JFIL TRA `AOR ARRAY \\
INFILTRATION BED \
\
INSTAL. INSPECTION \`
PORTS @ ALL 4 CORNERS
\
\
\
NOTE:
WATERLINE CROSSINGS REQUIRE THAT THE DRINKING WATER OR
WASTEWATER PIPE BE ENCASED FOR AT LEAST TEN (10) FEET
OF EACH SIDE OF THE CROSSING OR PLACE WHERE COMPONENTS
ARE CLOSER THAN TEN (10') FEET. PIPE OF SCHEDULE 40 RATING
OR BETTER MUST BE USED, OF SUFFICIENT DIAMETER TO EASILY
SLIDE OVER AND COMPLETELY ENCASE THE LINE. RIGID END CAPS
OF AT LEAST SCHEDULE 40 RATING MUST BE GLUED OR SECURED
IN A WATER -TIGHT FASHION TO THE ENDS OF THE ENCASEEMENT
PIPE. THERE MUST BE A HOLE OF SUFFICIENT SIZE TO ACCOMMODATE
THE PIPE IN THE LOWERMOST SECTION OF THE RIGED CAP SO THAT
THE CONVEYANCE PIPE RESTS ON THE BOTTOM OF THE ENCASEMENT
PIPE. THE AREA IN WHICH THE PIPE PASSES THROUGH THE ENDCAPS
MUST BE SEALED WITH AN APPROVED UNDERGROUND SEALANT
COMPATIBLE WITH THE PIPING USED.
1+� NATiRAL BACKFILL
�Zv
VAS%'i'
A/SAA//AA//AA/
�VA /VA/vV�VA/VA�VA/VA VEVA/VA/VA/VA/ ; VA,/ z
///�X\ X� //A///A//A /�X j g
Q pOOG'O( ��,o cr cO�G'O a O off' °a 'O'.c o A'G'O a Oa {n cO
O �J0a °0vO 000 °�'OoI_��04O� �O(D' C) aoQ L)o OOQQO��C o°OG�a �'V QCo� °o�U� N
ANDEEXET riEE�N� SHALL BE _ _ - _ - -__ aUUO a° Oo O �, DOC-�. <�� oo 0•OO° Oo�O�o�OO�'��O
WITHIN i IN. OF TOP OF TANK 0•� O"Q �'� 00 G
TYPICAL
GRAVELS
BOTTOM OF BED TO BE
FT SECTION "A" - TYPICAL INFILTRATION BED PLACED ON GRAVELS
NOT LESS THAN NOT TO SCALE (QTY MAY VARY)
9 INCHES OR MORE
NOT
AN 14.
INFILTRATOR UNIT
NATURAL BACKFILL
-
0aG -0G
THIS DRAWING SHOWS ALL EXISTING WELLS WITHIN SETBACK
-- a
'cam - v `. X00
DISTANCES (INCLUDING ON SURROUNDING PROPERTIES), CONTOUR INTERVALS,
--\:\
ALL PROPOSED AND EXISTING BUILDINGS, PROPERTY LINES, DITCHES, SLOPES
OF GREATER THAN 157, WATER LINES, SPRINKLER SYSTEMS, SPRINGS, SUCTION
SECTION
"B"
INFILTRATION BED
(IRRIGATION) LINES, DRINKING WATER CISTERNS, DRAIN TILES, IRRIGATION DITCHES,
PLACED ON GRAVELS
\\
NOT TO
LAKES, PONDS, WATER COURSES, STREAMS, FLOODPLAINS, FLOODWAYS, DRY
GULCHES, OR EXISTING SEPTIC SYSTEMS, AND ALL SUCH FEATURES ON
NEIGHBORING PROPERTIES WITHIN SETBACKS.
fg
\ \
9v
x
\ \
LINE
BEAM
MUANCE
\ \
\
L 1
N 35.UME
MR,
\
L 2
N 5&04'35'V
9026'
\ \ \
L 3
N 32W'59E
B6V
\ \
L 4
N 4MW47-E
3629'
\ \
L 5
N 626 &E
109.44'
\ \
\
L 6
L 7
N 1&M'9'E
N 19W'09'E
SW
5'
EAU,
�
\
L B
S 0&56'33E
1.90'
\
L 9
N 1004'P3'E
47.06'
L 10
L N
N L%Q%E
N 2&33'3PE
11625'
MY
L 12
N ENI 49N
2640'
36.814 AC f/—
BUILDING ENVELOPE FOR
C.4REFfIXING D#ELI,CNC UNIT/
IRRIG.4FIOXV BOLDING POND
0.9.2 ACRES
PLAN
C TEE INSTALLED TO
lBLE FROM MANHOLE
6 IN, MAX. BACKFILL OVER
OPENING COVER OF MANHOLE
FLUID
TRANSFER
SECTION
NOTIFY ENGINEEROF HIGH NWATER TABLE
ORF LINE F�ONNNIIONS 700 TANK. TANK
SEPTIC TANK DETAIL
NOT TO SCALE
PPAYIR SYSTEHTF\
_ I
-_ II
CROSS HATCH REPRESENTS
DITCH & POND SETBACK AREAS
LEGEND AND NOTES
i➢Ju' WWI W LS..110
0 ry rvn � 4 W u, 44su
B ¢T N REMR Ni ENVEIfPE Ctli�ER
-EpiE � N[M➢
—Onw LENiEPo.IIE a
5CAL-E; I" -- 200'
50.0'
IRRIGATION DITCH SETBACK
v 09
/0 I I
8 � I
I I
I
I I I
I I
I I
I I I \
I I \
\ DITCH S€TBAOv\ \\ \ \
\\ ` SEP\\TIC LINES
5\\PORT CONWRETl \
DI�TRIBU TION BOX \ \ \
JFIL TRA `AOR ARRAY \\
INFILTRATION BED \
\
INSTAL. INSPECTION \`
PORTS @ ALL 4 CORNERS
\
\
\
NOTE:
WATERLINE CROSSINGS REQUIRE THAT THE DRINKING WATER OR
WASTEWATER PIPE BE ENCASED FOR AT LEAST TEN (10) FEET
OF EACH SIDE OF THE CROSSING OR PLACE WHERE COMPONENTS
ARE CLOSER THAN TEN (10') FEET. PIPE OF SCHEDULE 40 RATING
OR BETTER MUST BE USED, OF SUFFICIENT DIAMETER TO EASILY
SLIDE OVER AND COMPLETELY ENCASE THE LINE. RIGID END CAPS
OF AT LEAST SCHEDULE 40 RATING MUST BE GLUED OR SECURED
IN A WATER -TIGHT FASHION TO THE ENDS OF THE ENCASEEMENT
PIPE. THERE MUST BE A HOLE OF SUFFICIENT SIZE TO ACCOMMODATE
THE PIPE IN THE LOWERMOST SECTION OF THE RIGED CAP SO THAT
THE CONVEYANCE PIPE RESTS ON THE BOTTOM OF THE ENCASEMENT
PIPE. THE AREA IN WHICH THE PIPE PASSES THROUGH THE ENDCAPS
MUST BE SEALED WITH AN APPROVED UNDERGROUND SEALANT
COMPATIBLE WITH THE PIPING USED.
1+� NATiRAL BACKFILL
�Zv
VAS%'i'
A/SAA//AA//AA/
�VA /VA/vV�VA/VA�VA/VA VEVA/VA/VA/VA/ ; VA,/ z
///�X\ X� //A///A//A /�X j g
Q pOOG'O( ��,o cr cO�G'O a O off' °a 'O'.c o A'G'O a Oa {n cO
O �J0a °0vO 000 °�'OoI_��04O� �O(D' C) aoQ L)o OOQQO��C o°OG�a �'V QCo� °o�U� N
ANDEEXET riEE�N� SHALL BE _ _ - _ - -__ aUUO a° Oo O �, DOC-�. <�� oo 0•OO° Oo�O�o�OO�'��O
WITHIN i IN. OF TOP OF TANK 0•� O"Q �'� 00 G
TYPICAL
GRAVELS
BOTTOM OF BED TO BE
FT SECTION "A" - TYPICAL INFILTRATION BED PLACED ON GRAVELS
NOT LESS THAN NOT TO SCALE (QTY MAY VARY)
9 INCHES OR MORE
NOT
AN 14.
INFILTRATOR UNIT
NATURAL BACKFILL
-
0aG -0G
'cam - v `. X00
900
GRAVELS
BOT -OM OFBED TO BE
SECTION
"B"
INFILTRATION BED
PLACED ON GRAVELS
NOT TO
SCALE (QTY MAY VARY)
0
i\
WATER -LINE
CLEANOUT
S " =10'
A. CALCULATIONS
1. PERCOLATION RATE = 23 MPI AVG. (H.P. GEOTECH JOB NO. 199 872)
2. DESIGN FLOW CARETAKER= 2 BEDROOMS X 2 X 75 X 1.75 = 525 GALLONS PER DAY (-2,000 SF RESIDENCE)
3. REQUIRED SEPTIC TANK CAPACITY = 525 X 1.25 = 657 GALLONS
USE ONE - 1,000 GALLON TWO COMPARTMENT CONCRETE SEPTIC TANK
4. ABSORBTION BED REQUIRED =
A= (525/5) *231/2=504 SF
DEDUCT 30% FOR INFILTRATOR BED = 353 SF
5. INFILTRATOR BED INSTALLATION:
353 SQ. FT./ 15.5 SOFT PER UNIT = 23 UNITI Iii
USE 4 UNIT X E UNIT INFILTRATOR ARFAY 124 PROviDED)
6. WELL SETBACK DISTANCE
100 + 8 * ((525-1000)/100) = 100 FEES
7. DITCH, STREAM AND POND SETBACK DISTANCE
50 + 8 * ((525-1000)/100) = 50 FEET
B. WATERLINE SETBACK DISTANCE
10 FEET TO TANK, 25 FEET TO FIELD
B. GENERAL NOTES
1. THE INFILTRATOR BED SHALL BE LEVEL (+/- 0.1 INCHES),
ON NATURAL GROUND (NOT IN FILL AND
MUST PROVIDE POSITIVE DRAINAGE AWAY FROM THE BED,
2. THE SEPTIC TANK SHALL BE LOCATED AT LEAST FIVE FEET AWAY FROM THE RESIDENCE
3. THE PIPE FROM THE RESIDENCE TO THE TANK MUST BE INSTALLED AS FOLLOWS:
THE PIPE MUST BE INSTALLED STRAIGHT IN ALIGNMENT AND GRADE,
IF A CHANGE IN ALIGNMENT OR GRADE IS NECESSARY, A CLEANOUT WILL BE REQUIRED AT THE CHANGE.
THE MINIMUM GRADE OF THE PIPE MUST BE 1/4" PER FOOT.
THE PIPE MUST BE A MINIMUM OF ASTM 3034 PVC PIPE,
A MINIMUM OF i CLEANOUT SHALL BE INSTALLED AT THE LOCATION WHERE THE PIPE LEAVES THE RESIDENCE.
THE PIPE SHALL BE A MINIMUM OF 4" IN DIAMETER.
4. THE PIPE FROM THE SEPTIC TANK TO THE INFILTRATOR BED SYSTEM MUST BE INSTALLED AS FOLLOWS:
THE MINIMUM SLOPE OF THE LINE MUST BE 1/4" PER FOOT.
THE PIPE SHALL BE A MINIMUM OF ASTM 3034 PVC PIPE.
THE PIPE SHALL BE A MINIMUM OF 4" IN DIAMETER.
5. USE RISERS TO BRING THE SEPTIC TANK ACCESS WITHIN 6" OF FINAL GRADE,
6. ALL MATERIALS, INSTALLATION PRACTICES AND SETBACK REQUIREMENTS SHALL
COMPLY WITH PITKIN COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS.
7. INFILTRATOR COMPONENTS TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS,
8. PLACE DISTRIBUTION BOX AND DISTRIBUTION PIPING ON 3/4" SCREENED ROCK.
SEAL ALL PIPES ENTERING DISTRIBUTION BOX WITH WATERPROOF MATERIAL
9. PROVIDE INSPECTION PORTS AT ALL 4 CORNERS
00003i
q,►,DO Rf�j �,,
'cPPoO^?Q1pOp��.
O �I9q`
f f.
wen
COf'YRIGIfi
0
�GX
® la
�i
DRAWN �Y
Of'
� O
a
0
Z O
DArt
11/2//99
RPVl51ON5
SGN.P
f�5 SnOWN
L)PAYING
I5U51'LAN
N07 -f-'5
and
OETiAIL5
5acer
0
PORT CONCRETE
'-)-'iSTRIBUTION BOX
6 INFILTRATOR ARRAY
INFILTRATION BED
INSPECTION PORTS.
@ ALL COR"�EF`�
CLEANOUT 111J4
�SEPTIC LINES
M
00
N
O
00
5GAL-E 1" _ f5'
0000��
-_�rt,�.�u fir;;;'^�•,
COPYR�GIfI" .�
P
_-- rl)�
DRi{NN HY
j
t
O
� � O
=;/o
RCV/5iC1N5
/5 SnOwN
'FAJ
DRAWlN'G
�rccr
I