Pitkin Count�vironmental Health & Natural Reso s Department
Pe for an Individual Sewage Disposal Joem
0405 Castle Creek Road, Suite 10, Aspen, Colorado 81611
Phone 970-920-5070 / FAX 970-920-5077
Permit# 05037 Parcel ID# 2467-174-01-005
Type of permit New( X ) Repair( ) Addition/Remodel to House( )
Name of Owner Hedy Longworth — Tom Misner
Street Address Holland Hills Road
Property legal description Lot Z
Size of lot 72 acres
Holland Hills at Basalt Subdivision
Total square footage of the house 3,629
Water source Holland Hills Water System
# of bedrooms in house 4 # of offices, lofts & similar sized rooms in house
Caretaker unit
# of bedrooms in caretaker unit
Designed for what # rooms (list)
Total square footage of the caretaker unit
# of offices, lofts & similar sized rooms in caretaker unit
4 bedrooms
Permit information
Designed by Schmueser Gordon Meyer
Mailing Address 118 W. 6'" Street, Suite 200, Glenwood Springs, CO 81601
Perc rate 15 Profile hole depth 8 ft Depth to groundwater or bedrock Greater than 8 ft
Minimum Septic tank capacity 1750 gallons Minimum Absorption area 542 sq ft wl 50% reduction
Comments
Septic permit approved per compliance with the engineer design and specifications dated May 4, 2006. Any
changes must be approved by this department and the design engineer prior to them being made.
Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin
County ISDS regulations. The engineer has stated that using minimum setback criteria is sufficient to prevent
contamination. The any ditch must be lined within 50 feet of the field. There must be at least a 10' setback to the
property line. Location of trenches should be staked out prior to excavation to assure the 50'setback can be
met.
This system will consist of one 2000 gallon two-compartment tank with an effluent filter on the outlet. A distribution
box will be used to split the flow to two trench systems. The first row of parallel trenches will have 14 Quick 4
chambers, and each row will overflow to another set of trenches with the same number of chambers for a total of 53
gravelless chamber trenches. There must be at least 6 feet of undisturbed soil between each trench.
This department does not endorse any brand of products. This permit must be kept on-site during installation.
The engineer must do a final inspection of the installation and submit an as -built letter to this department. This
department must also be called for an inspection with a minimum of 48 hours advanced notice.
'Revegetation over the area of the field is very important for the functioning of the system. Pitkin County has guidelines that must be
followed to assure the plants that are introduced are appropriate for the conditions of the area. The use of native plants is strongly
Permit approved by: ('CULCQ_ ,N_,C) Cly Date: c I I
Plans and specifications of the proposed individual sewage disposal system have been reviewed and are considered
satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin
County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was
issued unless system construction has commenced or an extension has been approved in writing by the Department. As -built
wings must be included with this permit before the final approval will be issued. Expiration Date: 11, 1 r— I o('
Cyr
Gc, C2
InStafler: eV�O��vo Qf_1Lnf(iA_r, License Number: C)Ap
Final approval: 1 zi g O Date: T an tN
Permit # 06024
Pitkin CountfA�nvironmental Health & Natural Reso s Department
Pell! for an Individual Sewage Disposal Skem
0405 Castle Creek Road, Suite 10, Aspen, Colorado 81611
Phone 970-920-5070 / FAX 970-920-5077
Parcel ID # 2467-174-01-005
Type of permit New( X ) Repair( ) Addition/Remodel to House( )
Name of Owner Hedy Longworth — Tom Misner
Street Address Holland Hills Road
Property legal description Lot 28, Holland Hills at Basalt Subdivision
Size of lot .72 acres Total square footage of the house 3,629
Water source Holland Hills Water System
# of bedrooms in house
Caretaker unit
# of offices, lofts & similar sized rooms in house
Total square footage of the caretaker unit
# of bedrooms in caretaker unit # of offices, lofts & similar sized rooms in caretaker unit
Designed for what # rooms (list) 4 bedrooms
Permit information
Designed by Schmueser Gordon Meyer
Mailing Address 118 W. 6'" Street, Suite 200, Glenwood Springs, CO 81601
Perc rate 20 Profile hole depth 8 ft Depth to groundwater or bedrock Greater than 8 ft
Minimum Septic tank capacity 1750 gallons Minimum Absorption area 876 sq ft w/ 30% reduction
Comments
Septic permit approved per compliance with the engineer design and specifications dated December 19, 2005.
Any changes must be approved by this department and the design engineer prior to them being made.
Minimum horizontal di ances between components of the system and physical features shall conform to the Pitkin
County ISDS regulations. The field must be at least 10 feet from the lined ditch, with the lining extending at least 82
feet from any portion of the absorption field. Any water fine within 25 feet of the field myet be encased. If the ditch
on the southwest side of the property carries water, it must also be 82 feet from the,681d or 10 feet if it is lined.
This system will consist of one 2000 gallon two-compartment tank and a bed consisting of 95 Quick 4 gravelless
chambV units (5 rows of 19) connected via a level manifold. A 10 mil PVC liner will be placed to the north and west
sides of field because of the proximity to the retaining wall.
This departrAbrlt does not endorse any brand of products. This permit must be kept on-site during installation.
The engineer nWst do a final inspection of the installation and submit an as -built letter to this department. This
department must also be called for an inspection with a minimum of 48 hours advanced notice.
'Revegetation over the area of the field is very important for the functioning of the system. Pitkin County has guidelines that must be
followed to assure the plants that are introduced are appropriate for the conditions of the area. The use of native plants is strongly
Permit approved by: Date: y 1 ILL
Plans and specifications of (he propos individual sewage disposal system have been reviewed and are considered
satisfactory. Permission fs herebynted to the owner or the agent to perform the work indicated in accordance with the Pitkin
County ISDS Regulation in effec),d the time of issue. This permit becomes invalid 6 months from the date that the permit was
issued unless system construction has commenced or an extension has been approved in writing by the Department. As -built
drawings must be included with this permit before the final approval will be issued. Expiration Date: t U, (-1W-
Instal ler:
a Final approval:
License Number:
Date:
•
PITKIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM
0405 Castle Creek Road, Suite 10, Aspen Colorado 81611
Phone (970) 920-5070 Fax (970) 920-5077
Name of OWNER /
Owner's Mailing Address 6
City,State,Zp Business Phone: 1z -
Home Phone: 22 7 eQ E-mail Address: /
/ � i
Primary Contact Person (all communication regarding this permit will go through this person)
Name
Com an
Contact Mailing
Address D D
City, State, Zi
Q
O7J
C �Business Phone: Z
Cell Phone :%
��
Fax: Z 7 U E-mail Address: .4 /J'A7 � /✓
Parcel ID # (available from assessor's office
at 920-5160 or at www.pitkinassessor.orq)
Street address of property Z 0Q/
Legal Description: Lot Block Filing Subdivision awl
Size of lot: , 7L acres. Type of proposed structure: � c
Total square feet of house f r # of bedrooms (potential) in house
r
Caretaker Unit: Attached ( ) Detached ( )
Total area(so. ft.) of caretaker unit # of bedrooms (potential) in caretaker unit
Permit is for: New Home ( Y.) Repair due to failure ( ) Remodel/Addition ( ) Emergency use ( )
Water: Private well ( ) Spring ( Stream ( ) Community/Public Water System
If community system: Name of system
The fee for a ISDS application is $600 for a permit that takes 6 hours or less for the department to approve. If approval takes
longer than 6 hours, a rate of $100 per hour will be charged. The maximum fee is $1000. The basic fee of $600 is due at the
time of application. The remainder, if any, will be due in two stages: first, at the time of issuance of the ISDS permit; second,
before final approval of the ISDS permit.
Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information is true and
accurate and that I have provided true and accurate information on locations of all existing and proposed wells, contour
intervals, buildings, property lines, ditches, slopes, waterlines, springs, suction or irrigation lines, drinking water cisterns, drain
tiles, irrigation ditches, lakes, water courses, streams, floodplains, dry gulches, and existing septic systems. I hereby certify
that any such features not shown on attached site map are not present. Issuance of the permit does not imply the approval of
any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all
approvals and permits have been obtained.
The Pitkin County Environmental Health Department, Pitkin County and employees of these agencies will be held harmless
should the individual sewage disposal system fail or malfunction. The permit to construct is issued on information submitted by
the applicant or his/her representatives. The ner assumes full responsibility in case of failure of the system.
Signature of applicant ��&68jV tj Date
Received by Receipt # 1 Date A"4
3
G:Vsdslisds appliclisdsapp Rev050103.doc
�D
•
Nancy Mackenzie
To: Matt Webster
Subject: RE: Holland Hills Lot 28
Matt,
40
1) Regulations allow us to waive the 4 times horizontal setback from a cut bank if a RPE can demonstrate that a
mechanical /natural barrier will prevent lateral effluent surfacing. So if it makes sense, we would allow you to do
this.
2) The HP soil testing was done Nov 22, 2002. So even though the ditch was on, there was minimal flow and it
appreared that the vegetation on the property was the type that likes water! That is why we require additional
profile/groundwater during spring run off.
3) The Ditch
a) We would need verification from the HOA & the Ditch company that the ditch can be lined or culverted.
b) I would need to know the "ownership" since there is a note in our file that the owner of the lot 29?, to the
north, said part of the ditch is on his property and he didn't want it culverted.
c) The ditch is really deep, can it practically be lined?
d) The draft design with the new house location and that large circular driveway doesn't appear to leave any
room for error in the location and the size of the system, especially if a partial raised mound is required.
So the best practice would be to get the ditch lined/culverted before the ditch is opened this spring (where it
encroaches on the 50ft plus the 8ft rule.
Nancy
From: Matt Webster [mailto:mattw@sgm-inc.com]
Sent: Monday, February 06, 2006 10:43 AM
To: Nancy Mackenzie
Subject: Holland Hills Lot 28
Hello Nancy,
As we had discussed on the phone about a month ago, I am working on an ISIDS design for Tom Misner's
property - Lot 28 at Holland Hills. They are looking at putting in a driveway downhill from the drain field. The cuts
required for the driveway would be several feet deep, resulting in the need for a retaining wall. Due to site
constraints, we are not able to obtain a horizontal separation of 4 times the vertical drop from the bed to the
driveway. However, we were going to design the bed with a liner around the downhill sides to prevent lateral
movement of the effluent. This should satisfy the requirement of a mechanical barrier to prevent lateral effluent
surfacing, but I wanted to check with you to see if you had any concerns with this approach.
Also, Tom has indicated that the ditch was most likely flowing when HP did their original subsoil investigation (and
did not find any standing water in their test pits). If we can verify that the ditch was in fact flowing at that time,
would this suffice as evidence that groundwater will not be an issue for the ISDS. Or would you still require
another test pit after the ditch is lined?
Let me know if you have any questions about any of this.
Thanks for your help,
Matt Webster
2/6/2006
0 0
SCNMUESER GORDON, MEYER
c M O I N c c n S SURVEYORS
1 18 WEST 6TH STREET. SUITE 200
GLENWOOD SPRINGS, CO 81601
970-945-1004 / FAX: 970-945-5948
WWW.SGWINC.COM
No virus found in this outgoing message.
Checked by AVG Free Edition.
Version: 7.1.375 / Virus Database: 267.15.2/251 - Release Date: 2/4/2006
2/6/2006
0 0
Matt,
I have talked to Tom Misner in the past, but I'm not exactly sure which job that was for.
Generally, lots in Holland Hills are small and soils are pretty consistent. If the field will be in any
proximity to a ditch (there are many in Holland Hills), we could require a spring/early summer
profile hole to be sure runoff or irrigation water will not influence the groundwater table in the area
of the field. I guess we need to look at the site and analyze whether or not the peres from 2002
would be representative in the proposed new field location. Could we do a site visit? There is
quite a bit of snow on the ground now, but as I mentioned before, Holland Hills lots are generally
small and I bet we could get a better feel for it by checking it out. Let me know when you might
want to do that.
cb
Carla Block, REHS
Pitkin County
Environmental Health and Natural Resources
970-920-5438
From: Matt Webster [mailto:mattw@sgm-inc.com]
Sent: Friday, December 16, 2005 3:09 PM
To: Carla Block
Subject: NOT Pitkin Iron Related!
Carla,
I just got handed a project with an ISDS design for a homesite in Holland Hills. A Subsoil Study
was conducted by HP Geotech for the former owner, and included percolation tests and a profile
pit. Upon reviewing the report, I was concerned with two issues: 1) the perc test locations may
not match where the current owner wants the ISDS, and 2) the percolation tests were conducted
on November 22, 2002 (i.e., after the November 15 deadline). I am wondering if this subsoil
study will be adequate for the design of this system.
Apparently, the previous owner had been through a certain amount of permitting/approval with
the County, although I'm not sure how much interaction he had with your office. The relevant
information is as follows:
Site Location: Lot 28, Holland Hills, Pitkin County, CO
Previous Owner: Bill Swanson, 914 Water Avenue #17, Aspen, CO 81611
Current Owner: Tom Misner, PO Box 393, Basalt, CO 81612
The HP Report is dated December 6, 2002 and the project is HP Job No. 102754
Are you aware of this project and/or subsurface study by HP? I'm not sure if the profile pit is still
available for observation but could visit the site to check (granted, it will have been exposed for 3
years). Also, given the date of the percolation tests, will we be able to use this information in the
design?
Let me know if you have any questions or if there is other information I can provide
Thanks,
Matt Webster
4/4
Z/Z
3DVd
0
• •
PITPUN COUNTY ENVIRONMENTAL HEALTH & NATURAL RESOURCES
DATE: 8/30/2006
Send to: Tom Misner From: Alicia Gomez
Fox Number; 927-3280 Phone Number: 920-5087
CC: All Service SepitcNumber of Pages, Including Cover: 2
CC Fax Number: I
O URGENT O REPLY ASAP 0 PLEASE COMMENT E3 PLEASE REVIEW ® FOR YOUR
INFORMATION
COMMENTS:
Septic Permit # 06037 for parcel 2467-174-01-005, owner
Longworth -Misner, has been finalized. Please feel free to call
920-5070 if you have any questions.
fax cover
Pitkin County Environmental Health and Natural Resources
0905 Castle Creek Road Sulte ✓L10, Aspen, CO 81611
Phone (970) 920.5070 1 Fax (970) 920.5077
Web site w .aspenpftkin.com/ehnr
NOIID3NNOD 311NISDv3 ON (Y-3 M3MSNV ON (E-3
ASno (Z-3 11tld 3N11 Mo in D'ON (l-3
NONN3 NOi Nosv3w
---------------------------------------------------------------------------------
NO 08Z£LZ6
N0 Z13d WIl
----------8-----------------------------------V---------------------
ilnS
Wd00: Z 900Z '0£ 'DTIV
3DaNOS38 1vN H11V3H 08IAN3 :a3MH XV3
* * * ( Wd£0 Z 0Z '0£ 'Dnv ) AWH 1111S38 NOIIVDIWWOD #
l 'd
Xl AWNM £L5
------------------
300104 31I3
03HOIS/0311IMN" I
------------------------------
REASON FOR ERROR
E-1) NANO UP O0. LINE FAIL
E-3) NO ANSWER
• •
----------------------
E-2) BUSY
E-4) NO FACSIMILE
PITKIN COUNTY ENVIRONMENTAL HEALTH & NATURAL RESOURCES
DATE: 5/17/2006
Send to: Tom Misner From: Alicfa Gomez
Fax Number: 927-3280 Phone Number: 920-5087
CC: All Semite Septic Number of Pages, Including Cover: 2
CC Fax Number:
O URGENT L3 REPLY ASAP Q PLEASE COMMENT O PLEASE REVIEW ® FOR YOUR
INFORMATION
COMMENTS:
A septic permit (# 06037) has been issued for parcel 2467-174-01-005,
Holland Hills Road, owner Misner. This replaces permit #06024. Please
feel free to call 920-SO70 if you have any questions.
NOTE: Effective April 8, 2006 a licensed Installer must Install the ISDS
System and EH/NR must be notified prior to installation who that
Person/company is to check for installer's compliance with our new
regulations.
fax cover
Pitkfn County Environmental Health and Natural Resources
0405 Castle Creek Road Suite 410, Aspen, CO 81611
Phone (970) 920.5070 I Fax C970) 920.5077
Web site www.aspenPitkin.com/ehnr
Cl
P. 1
x
s x CONDICATION RESULT REPORT
( MAY. 17. 2• 2:53PM )
x x x
FAX HEADER: ENVIRO
HEALTH NAT
RESOURCE
TRANSMITTED/STORED
MAY.17.2006 2:50PM
FILE MODE
OPTION ADDRESS
RESULT
PAGE
----------------------------------------------------------------------------------------------------
240 MEMORY TX
TIM PETZ
OK
2/2
9273280
OK
2/2
------------------------------
REASON FOR ERROR
E-1) NANO UP O0. LINE FAIL
E-3) NO ANSWER
• •
----------------------
E-2) BUSY
E-4) NO FACSIMILE
PITKIN COUNTY ENVIRONMENTAL HEALTH & NATURAL RESOURCES
DATE: 5/17/2006
Send to: Tom Misner From: Alicfa Gomez
Fax Number: 927-3280 Phone Number: 920-5087
CC: All Semite Septic Number of Pages, Including Cover: 2
CC Fax Number:
O URGENT L3 REPLY ASAP Q PLEASE COMMENT O PLEASE REVIEW ® FOR YOUR
INFORMATION
COMMENTS:
A septic permit (# 06037) has been issued for parcel 2467-174-01-005,
Holland Hills Road, owner Misner. This replaces permit #06024. Please
feel free to call 920-SO70 if you have any questions.
NOTE: Effective April 8, 2006 a licensed Installer must Install the ISDS
System and EH/NR must be notified prior to installation who that
Person/company is to check for installer's compliance with our new
regulations.
fax cover
Pitkfn County Environmental Health and Natural Resources
0405 Castle Creek Road Suite 410, Aspen, CO 81611
Phone (970) 920.5070 I Fax C970) 920.5077
Web site www.aspenPitkin.com/ehnr
Cl
P. 1
x x x COM6ICATION RESULT REPORT ( APR.19.20 10:22AM ) x x x
FAX HEADER: ENVIRO HEALTH NAT RESOURCE
TRANSMITTED/STORED APR.19.2006 10:21AM
FILE MODE OPTION ADDRESS RESULT PAGE
---------------------------------------------------- -------------------------------------
164 MEMORY TX 9273280 OK 2/2
-----------------------------------------
REASON F)OR ERROR
E 3) NONANSWE RR LINE FAIL
4D 40
-----------------------------
E-23 BUSY
E-4 NO FACSIMILE CONNECTION
PITIQN COUNTY ENVIRONMENTAL HEALTH 8t NATURAL RESOURCES
DATE: 4/19/06
Send to: Tom Misner
From: Alicia Gomez
Fax Number: 927-3280
Phone Number: 920-5087
CC:
Number of Pages, Induding Cover: 2
CC Fax Number:
O URGENT E3 REPLY ASAP
0 PLEASE COMMENT O PLEASE REVIEW On FOR YOUR
INFORMATION
COMMENTS:
Tom,
Here is a copy of the permit Carla tried to give you yesterday. She also asked that I
Inform you that the setback to any ditch that is unlined must be 82 ft. If the ditch is
lined, the setback Is only 10 feet but the ditch must be lined within 82 feet of the
absorption field. You should (or have SGM) double check the distance from the
proposed leachfield — the one that was permitted — to the ditch that has already been
Ilned/culverted to be sure it extends far enough from the proposed field (82 feet).
And as a general reminder: Effective April 8, 2006 a licensed installer must install
the ISIS system and EH/NR must be notified prior to Installation who that
person/company Is to check for installer's compliance with our new regulations.
Let us know If you need any additional information, or have any questions. You can
call us at 920-5070.
-Alicia
fax cover
Pitkin County Environmental Health and Natural Resources
0405 Castle Creek Road Suite #10, Aspen, CO 81611
Phone (970) 920.5070 I Fax (970) 920.5077
Web site ww .aspenpitkln.com/ehnr
F1
COMMOCATION RESULT REPORT
APR.
Fax Number:
P. 1
• ■ •
( 17. 20.1:08PM )
IK*
0 URGENT O REPLY ASAP
FAX HEADER: ENViRO
HEALTH
NAT RESOURCE
TRANSMITTED/STORED APR.17.2006 1:07PM
FILE MODE OPTION ADDRESS
RESULT
PAGE
----------------------------------------------------------------------------------------------------
158 MEMORY TX SGM
OK
2/2
--------------------------------------------
IFASON F)OR ERROR
E-91 NOF
NANSWERR LINE FAIL
• • f"k
--------------------------------
E -H BUSY
E-4 NO FACSIMILE CONNECTION
PITKIN COUNTY ENVIRONMENTAL HEALTH & NATURAL RESOURCES
DATE: 4/17/2006
Send to: SGM
From: Alicia Gomez
Fax Number:
Phone Number: 920-5087
CC:
Number of Pages, Including Cover: 2
CC Fax Number:
0 URGENT O REPLY ASAP
Q PLEASE COMMENT O PLEASE REVIEW ® FOR YOUR
INFORMATION
COMMENTS:
A septic permit (# 06024) has been issued for parcel 2467-174-
01-005, Holland Hills Road, owner Heady Longworth — Tom
Misner. Please feel free to call 920-5070 If you have any
questions.
NOTE: Effective April 8, 2006 a licensed installer must install
the ISDS system and EH/NR must be notified prior to installation
who that person/company Is to check for installer's compliance
with our new regulations.
fax cover
Pitkin County Environmental Health and Natural Resources
0405 Castle Creek Road Suite #10, Aspen, CO 81611
Phone (970) 920.5070 1 Fax (970) 920.5077
6, C)
fill
ro�2014
6l ",4swing,,coa1602
SENYI� 90970616-S033
'I W303-2162796
August 11, 2006 Project No. 1181
Tom Misner, Inc.
PO Box 393
Basalt, CO 81621
Installation Observation, Proposed Residence
Lot 28, Holland Hills Road
Pitkin County, Colorado
Mr. Misner,
WEIVED
AUG 2 g 2006
PITXIN CUw1 r
HEALTH g MTURAL RESOURCES
ALL SERVICE septic, LLC and Pitkin County performed installation observations on August 41h and
I Os' 2006, for the subject property.
The installation included one 2000 -gallon, two-compartment precast concrete septic tank with an
effluent filter on the outlet, and six `Quick -4' chamber trenches. Two trenches had 14 chambers, two
trenches had 10 chambers, and two trenches had 4 chambers, for a total of 56 `Quick4' chambers
and 553 SF of infiltrative area. A distribution box and serial distribution will be used to distribute
effluent. An as -built drawing is included.
Upon fugal grading surrounding the residence, two risers and lids should be installed to bring the
septic tank to grade.
The OWS was installed according to specifications. This observation is not a guarantee of
workmanship and/or parts and materials. ALL SERVICE septic, LLC should be notified if changes
are made to the OWS.
Sincerely,
ALL SERVICE septic, LLC
�, r..,.
Timothy R. Petz
Reviewed
Richard H.
2 copies sent
Copy sent to Pitkin County Health Department, Attn: Carla Ostberg
I3
•OWS AS -BUILT
2000 -GALLON,
TWO-COMPARTMENT PRECAST
CONCRETE SEPTIC TANK, WITH
EFFLUENT FILTER ON OUTLET
4" PVC EFFLUENT LINE
DISTRIBUTION BOX,
553 SF OF INFILTRATIVE AREA IN 6
GRAVELLESS TRENCHES. \
TWO TRENCHES HAVE 14 CHAMBERS
TWO TRENCHES HAVE 10 CHAMBERS
TWO TRENCHES HAVE 4 CHAMBERS 4" PVC
LINES
FOR A TOTAL OF 56'QUICK-' CHAMBERS
PVC OVERFLOW LINES WIWERE
SLEEVED NTH SCHED 40 PV
AND INSULATED WITH
SCALE
1"='V'
NORTH
0
Holland Hills Metropolitan District
517 East Hopkins Avenue, Aspen, Colorado 81611 Tel. 970-925-3475 Fax 970-925-4754
Board of Directors
Kent Schuler Peter Abplanalp Barb Schutz Tom Misner
Carla Block
Pitkin County Environmental Health
0405 Castle Creek Road
Aspen, Colorado 81611
Re: Lot 28 Holland Hills Road
Dear Carla:
April 12, 2006
This letter will confirm that the property at Lot 28 Holland Hills Road has completed work to
partially line and partially pipe a section of the Kester Ditch above Lot 28. This ditch work was
completed to satisfy setback requirements of the Environmental Health Department. The
improvements include a buried 40 mill polyethylene liner in combination with a buried 36" ADS
"N-12 polyethylene pipe.
At the request of Mr. Tom Misner, I inspected the ditch today and have found the improved
sections have been constructed in a sound and complete manner and the improvements should
adequately prevent water from seeping from the ditch.
Should you have any questions regarding the installation, please give me a call.
Sincerely,
By
Gary . each
District Manager
1'Ir
Email to HHMD@beachresource.com
0276 Misner ditch improvempd
I l�
• • Page I of 1
Carla Block
From:
Matt Webster (mattes@sgm-inc.coml
Sent:
Tuesday, December 20, 2005 10:00 AM
To:
Carla Block
Subject:
Holland Hills Lot 28
Attachments: Lot 28 Subsoil Study.pdf; Improvement Survey.pdf; site plan.pdf
Carla,
I've attached the HP Geotech soils report, the Improvement Survey and a site plan with topography and a rough
location of where the house may be located.
It looks like the Kester Ditch runs along the eastern edge of the property. The perc test holes and test pit were
located in the center of the property. Based on the desired house location, the gas line that runs along the
western side of the property, and the driveway (the owner wants a circular drive although the location is not
currently known) - we are probably looking at locating the drain field in the southern/southeastern portion of the
property. I think the owner wanted it along the western edge, but I'm not sure we can accomodate that given the
constraints. In any case, a substantial portion of it should be within about 50-75' of the original perc tests.
The perc test results were 20, 15 and 9 MPI for an average of approximately 15 MPI. No free water was
observed in the pits, which ranged from 6.5' to 9' deep.
Let me know if you have any questions or need any other information
Thanks,
Matt
^Webster
SCHMUESER GORDON MEYER
[ N O I N [LRS OURVEYORS
1 18 WEST 6TH STREET, SUITE 200
GLENWOOD SPRINGS. CO 8 1601
970-945-1004 / Fix: 970-945-5948
WWW.SGWINC.COM
No virus found in this outgoing message.
Checked by AVG Free Edition.
Version: 7.1.371 / Virus Database: 267.14.1/207 - Release Date: 12/19/2005
12/20/2005
y
rEntT o.
LOT 26
Z5' UIWRY EASEMFNY a \ A
w
GRAPHIC SCALE
+ form)
L IM6-m n
E2KD64' A23rER prAl
LOT 29
I R-239.34
L-170.40 \\\
CB -N54 12-W \� `h •,\\ \
0166.63
ZAz
g f
�]' s L ♦ ILT
1 I
VOW
414,
SITE MAP
SCALE: 1 INCH = 20 FEET
NOR N Wn MVROOYAM, P O M. W1WWAL MTML w
W r`.0 mEA. 1MFN WLQ IWm 111111NE f UTA A "A"A-m
YATpDK Rq MKIO TAY.
TYPICAL LINED DITCH CROSS SECTION
ICTAL
9
Legend and Notes'
0 A~As /wne mwvm.nr o: Wwzee
- 9[anpa e. Dwse uyM o /s .,Dw w/n v pao. Palk cqo cS 195"
/Dune N Me ,arMruMy eanx mE o /5 nOw N!M1 a np LS 11J1
hone ul A svuMvlY G>ilf .1 --1— boll a A,6A0 4.1 TG
tir9 . L , a/ S 114 6T A.1— xre mw+uns/fi
- MA . net 11 m hrprPlNrrN+f ,[ y>
Fyro f bmrM —11AAAh.
awe mgpiry Aa D rryoygMkH Y.IeY rnrp Al MI 2A n.d MN,
[f Ba»YI DY Iufrve Sww/Yr0 .SNA[., oafM pecwnDs fT TP]T
T.s avwy sl[he if eJ nol ryvefMl Olith ,awM Dy Me
eeaenm 9c Nwremrne v.nxen6 w h eircv.s
f/rx sravmymcef oI rKpy. M n/mm[lim
OxfIX+)rq a,nNH{+, ,e 1. n eller 21.
bw numb. o/ rxae
Demr faY¢v bmr w Impownsr! ]Lr Y MDy NryM
Nipf Cawhy CngirwA4 k[.. Jafee A.. 21. TGtl].
- Mb p .,, h fv0/ , h eppwwrr ewmnwrh (w
ealsfh9 Ililn.
mA�v°rtA>y r. � r ry .v+emenrA o,nr .1 .vr
none A Ine �xvEe n/nrne RIFM CwnlY bei 0
PRCPOSFD A &T OIX AY
\ PRONOE AO' L04 M a lr
R1MM rM pRIYEYIAY WUKAA E
ADB -N12
QA FEF113F55 L11MW1 SETBACK INFVI(YAIIAI:
3 R MCC LDOE 01' OSS E ENT
B R 8201E OMW11VAY
6 R SEPMATON BEIYEEN (NAAUB S
n, AP k LOLATIM M(XILkPM HOLE
❑ APMOk LO TM PiNIRLE RT
"AM
I PLC LINED INTIM
10
00
b' R1CN d)LMLRT
,31
m AWE
ASE
�ASME M
Y6LY
REEK
.E SrfID .]R
MIA ... RMES VIE MSTE WTWµ YAA RA00LL)
12' 91. 1lr W1 ..F
r ASTM. A ESSSIE RR TIdd1011FN[M W
MS -MS RPE KALA ELSlllq gi01 f1ElIEK AT .1.1 9Y
/ IY
P09nVE 9.a M. MO LOA PONn YLL ; KLYSm N ME iV£
AE .8118 91KL SE MNIELEO YM 0.9380 AMIOS
TYPICAL PIPED DITCH CROSS SECTION NMMMTNa( R'Al
N L.S TEAM m11M SIAL BE ILA AM
WlIII1K CIMR9 Dt mUM IMCPY.CIW AlIEA2
NOIU WrII rWT AWiK M lIW1 SOTTOI V)O Ipl LOIYATU
TRENCH CRQATSECTION (TYP.)
IOgYME W
WrMIX N w w NL1MT113 IMT
RSI NSLYlA1{N 6 WAI qt
RPE
0
INSPECTION WELL DETAIL
I. TA... 91.1LL NOT 1. 1. AIT.
2. ME BOTTW W EMN TleN MTA1 WE IEKL.
]. OPANA. g1OlEs ME ro WE rRONDFO IHJK MA MXIIMD TgppES
. KE£SWT. ro MEgIT RM1(E MNOR IA91 ENnAWC
A Tw MEA
.. NSTA 1 MLTUTtlI N .b]'YS WIQ NM Y.WIfI.C11MEs 16LOYENO,nMS
ppLpY. pr[S
T. PFR[nArrM WR A.INY M Tri rOLLwrM TEsrs IpEOR[D M aITE ry
NFROf1Y-P/�M' oEDRONILY..
r NnE •hl' m..w,Ww
RAC MLE •FE' IS YIN/Ilpl
RRL 1rLE •N• r YIM/IMOI
•VEWLE VR ATIM RATE • Ir MIM RR I.; IR M .1. RR INTI
]. YOMSE SNS NOO L R. At IW 60
] BEOROO6 M YMI IW.{
1 BmRMI N OR G AAA IMT
Ld.K Olt. RAR R(I! M ORI
VRK RATE ID YN. /LOI
OEYp iLOI (0) I ✓ AD nAL 6fpR016 A 2 PEVIE / 91 A Op A I'M
o- rnu
ASS 1011 YEA (� =91 rml WlE)
ll QA'•EIlF53 MAIIINR MIR MMJIT REMICIIPI
A WCYWT. A/. A.
TAJtTA
TYPE OE SIShTF. WilN£5] p415EA]
YEYM T. EAP... I.I. QYlOR
SC,6.C11 FlIYI .ELL: Y/A
sETRN2I fAM YSIFX oTOA W PQi (oTp1 WSr B£ 1im W IJId Y1Y FWT.
]. ALL ORIRFTIM WAALL K IN ACEM RIM TIE NKW WLNn
MR 0014W OPMT[IR or IEKM (WMI) REIiEATIOTM ar w RYL
sERIM 0190iµ SYSTEM. EMI TIYMI ALL SVM I IAEMERis .N[ w
VFLIrIGLv NONTI M 1. AWWWW' E. TIE OMMILTM WALL H
690MIM S . AMA MC.I:C DETAILS A AME IET.. TO Ix
rIE AWL�EIrr IC1E0 IECIR.Lnpe.
A. T .I: ..L EMI 1. V. WV AN WE .1.E Ir AT Is N .MT
S. NT. NI SRWEMT MM (•MpW Mlfld' a 90TAIE EiRLEnT M. M
MPR?�f0 E1 ) AT WM MD IF >mM i/lIK
A. 9VM TNq. RE W (M "AAW M , DYT' PIASTO p.01CT 10
R1Y11 MMIY! EWWWXWS I➢PRO'
). OYM '•We HMPAO Tp Mix AAmi LLM MT E TExS N ELgETE M
S. WRIm WTA N IFAOI rRD AREA MMT WE MMTIM .T LEAST iRIII RQ13
MRI
Wife IS FL= N M MINTER MIX
A. WWICA O ONrr1L IS Rm1111M M M SVrw rlm M rMFt AREA,
LO. MEATdTS ME AEW 1RE0 AT /LL rum AM AT LEAST COUNT 100
rLET µpfi M MORE 01A11n XIR.
11. INSTALL RISEM M MRSSMT R MIM µL AE M MINTS TO
MIMIN 1/SiSOr W SINE WOE.
12. LWATIU6 W ALL LOWMNTS WT R VMI W M NEOES9M A LO
M ALL MINI" OISTAIAMS M9 KMS WET 1 E REWIRED.
IS. PNEI. VWIT.W 941NAW w 9MIL5 WAM AWT TEA
PR011 A
MINIM ME AIMVWALE, A WaSSMT.
1A. MIS .1. OO LS NTT UNIrITMTE M NSW FERNY. PMIT
Y5T 4MTAIIm IIWIF
ARPI11.lE CIIT M QAMY 6
rISIM3.
EWIMER MAT O®IYL MWIIYILTM SKIM STEW RATEILL
YO RWIM IEIVIT r000/RT.
IS. Is MIDI IS SISW M r111GL p0(SrIC W3rF5 MT. 6VHYM M
rWAIIW RTM PM REMAIN (MAEGIS WITS M WEA MWTEMA6 M
r TEM M4LLO WET WE NOm110m .Mrs sYSiFY.
1A. WINE MMI. PAW0WWW LA.... W,
- 3
41L1
11,.111,111"DS
0
JAN.21.2003 11:51PM
MSDN 343 ASPEN
Mrs
P.2
Request to pipe the Kester Ditch on Lot # 28 Holland Hills Dr.
I, William E Swanson Jr. have a contract to purchase Lot # 28 on Holland
Hills Dr. in Basalt Co. contingent upon being able to pipe the irrigation ditch
that you maintain and that runs through Lot # 28. The ditch is highlighted on
the enclosed survey.
I am requesting permission to pipe this ditch in its entirety. I would use 36"
ADS Plastic Pipe and connect it into the 36" ADS Plastic Pipe that currently
runs under Holland Hills Dr. and into Lot # 28. The pipe would run from this
point to the end of lot # 28 to where it connects with Lot # 26. The ditch
would then be backfilled, tamped, covered and graded.
!, SWAA- GR-t'ste wtLi- qui. pw.re.h Nr rtrt fws( ttw� P<v steP�n{. C.th-
The work will commence and be completed during the period the ditch is
shut down Nov, to April. Please provide the date's water will not be running
in the ditch,
All of the work, including materials and labor will be done at Mr. Swanson's
expense.
By signing this letter both parties acknowledge this agreement, agree to it
and The Kesler Ditch Co. grants William E Swanson Jr. and his agents the
right to pipe the ditch as described.
Signed:
William E Swanson Jr. ',Ad- -, � Dated A Z` �
7
The Kesler Ditch Co. ' Dated /Y D 3
Printed name of signer.- vl0 p ({yl
Position:
V-,(�S,RA () <* T -din oV-F pV-c. -AO-N> Z-O-Ic,-L jo,
Holland Hills Metropolitan District
517 East Hopkins Avenue, Aspen, Colorado 51611 Tel. 970-925-3475 Fax 970-925-4754
Board of Directors
Kent Schuler Peter Abplanalp Barb Schutz Tom Misner
r•�siiU)yMor.
Suzanne Wolff
Pitkin Community Development Dept.
130 S. Galena Street
Aspen, Colorado 81611
Re: Water Service to Tom Misner Property
Dear Suzanne:
This letter will confirm that the Misner property lies within the corporate Boundaries of the
Holland Hills Metropolitan District. The Holland Hills Metro District provides potable water
service to properties within the District through a Colorado State approved public water system.
The system identification number is PWSID # CO 0149352 and a ground water source has been
adjudicated Under Case Nos. 99CW319 in Water Court Division 5, and the water supply meets
or exceeds all federal and state water quality standards and a fully operational pumping,
treatment and distribution system is in place to deliver water to all properties currently within the
District.
The Misner property is therefore eligible for water service from the District upon completion of a
water service application, payment of processing and inspection fees and the installation of a
District approved water service line and water meter.
The Misner Property is also served by District maintained asphalt roads including Holland Hills
Road and Bishop Lane. Misner is eligible to access these roads, and use of the roads during
construction by heavy vehicles is permitted according to the rules of the District. All proposed
cuts to the road and access points must be pre -approved by the District.
Sincerely,
By
ach
Distract Manager
i7
Email to HHN4D@beachresource.com
0276"s niL i .wpd
� r
IMP'I20VEMNT SURVEY
LOT 2 , HO HILLS AT BASALT
ACCORDING TO THE PLAT RECORDED MARCH 27, 1970 IN .PLAT BOOR 4 AT PAGE 252
COUNTY OF PITEIN, STATE OF COLORADO
5
i
N�U12-24-. w 77
a
\ 4N �`. ` .. �`. `� �� - '"wpm us -� � ��1.: ��'t— -- -- � ..�.;.. "'��Y'.•.
o-tesns � ti [6
J
\\ �1 w➢E mol`��`�Iesd,{Vn1,twww ��.
.. " tma lam\ \`; •wsR'.`°�•' � � 'u M�(zN
�. � .. - .yo* �•:' � ` .sat�,c:.^�.°tr°°xms•'�o� A rjg �8
S.E�a Tom'
Hill
un" �"'
0
0
HOLLAND HILLS AT BASALT
SUBDIVISION PROPERTY OWNERS ASSOC.
C/o Beach Resource Management
715 W. Main
Aspen, Colorado 81611
January 27, 2003
Pitkin County
Environmental Health Department
130 South Galena Street
Aspen, Colorado 81611
Attn: Nancy McKenzie
RE: Swanson CDU Special Review
(PID# 2467-174-01-005 CASE# P005-03)
Dear Ms. McKenzie,
RECEIVED
FEB 3 2003
PITKIN COUNTY
EPAIJIRON�)ENTAL HEALTH
Thank you for including us in your review of this application. Enclosed please find our
Architectural Control Committee pre -approval stipulation letter to Mr. Swanson- Your
attention is directed to page 5 of our stipulation letter and the following language:
"SPECIAL REVIEW FOR CARETAKER DWELLING UNIT
We have reviewed your submittal to Pitkin County, Swanson CDU Special
Review (PID# 2467-174-01-005 CASE# P005-03) and are submitting comments
at their request. We disagree with your responses to Section 3-210-020 General
Standards and Criteria, i.e.
Sections D, E & G.2.: Based on the exterior fagade, colors and refinishing
techniques you indicated in conversation and the elevations you provided to
us. Without revision, your project will not be in harmony with the
surrounding area, and will negatively effect the neighborhood
Section G.1.: The public health, safety or welfare cannot be guaranteed unless
you agree to all of the stipulations regarding lining or culverting of the Kester
ditch.
In summary, we cannot support your special review application without first
receiving your signed approval and agreement to all of the stipulations included
herein."
91 r
0 0
We have shared this letter with Mr. Swanson and are awaiting his reply. We appreciate
the support of the Community Development Department in our efforts to maintain a
quality neighborhood environment while protecting our investments.
As per your request, we have measured the Kester Ditch culvert under Holland Hills
Road. It is indeed 36" inside diameter. Please call if we can be of further service.
Sincerely
Monroe Sui
Committee
Enclosure
Cc: Board of Directors
Contiguous property owners
Environmental Health Department
as
9 0
HOLLAND HILLS AT BASALT
SUBDIVISION PROPERTY OWNERS ASSOC.
C/o Beach Resource Management
715 W. Main
Aspen, Colorado 81611
January 27, 2003
Pitkin County
Community Development Department
130 South Galena Street
Aspen, Colorado 81611
Attn: Ezra Louthis
RE: Swanson CDU Special Review
(PID# 2467-174-01-005 CASE# P005-03)
Dear Mr. Louthis,
Thank you for including us in your review of this application.
Enclosed please find our Architectural Control Committee pre -approval stipulation letter
to Mr. Swanson. Your attention is directed to page 5 of our stipulation letter and the
following language:
"SPECIAL REVIEW FOR CARETAKER DWELLING UNIT
We have reviewed your submittal to Pitkin County, Swanson CDU Special
Review (PID# 2467-174-01-005 CASE# P005-03) and are submitting comments
at their request. We disagree with your responses to Section 3-210-020 General
Standards and Criteria, i.e.
Sections D, E & G.2.: Based on the exterior fagade, colors and refinishing
techniques you indicated in conversation and the elevations you provided to
us. Without revision, your project will not be in harmony with the
surrounding area, and will negatively effect the neighborhood.
Section G.1.: The public health, safety or welfare cannot be guaranteed unless
you agree to all of the stipulations regarding lining or culverting of the Kester
ditch.
In summary, we cannot support your special review application without first
receiving your signed approval and agreement to all of the stipulations included
herein."
0
0
We have shared this letter with Mr. Swanson and are awaiting his reply. We appreciate
the support of the Community Development Department in our efforts to maintain a
quality neighborhood environment while protecting our investments.
Sincerel
Monroe Summ
Committee Chairperson
Enclosure
Cc: Board of Directors
Contiguous property owners
Environmental Health Department
aq
0
0
HOLLAND HILLS AT BASALT
SUBDIVISION PROPERTY OWNERS ASSOC.
C/o Beach Resource Management
715 W. Main
Aspen, Colorado 81611
January 27, 2003
Mr. Bi11 Swanson
914 Waters Avenue
Aspen, Colorado 81611
RE: Lot 28
Holland Hills at Basalt Subdivision
Architectural Review
Dear Mr. Swanson,
In accordance with the covenants and by-laws of the Holland Hills at Basalt Subdivision,
our Architectural Control Committee met with you and your representatives on the
evening of Thursday, January 9, 2003. The purpose of the meeting was to review the
plans and specifications for structures you wish to build on Lot 28. We have 30 days
from this meeting to provide this response to your application.
Contiguous property owners were invited to provide input and comments as well as voice
any concerns they may have about the project. All contiguous property owners were
represented either in person or by proxy. A representative of the Kester Ditch Company,
Darwin Barta, was also present to provide input on your desire to alter the ditch.
Members of the committee present included:
Monroe Summers
Peter Abplanalp
Rich Walker
Kent Schuler, President of our Homeowners Association, and also a member of the
Architectural Review Committee was present as a contiguous homeowner but recused
himself from final review of the application. This was done because the current owners
of Lot 28 feel he has a conflict of interest. We disagree with this assessment but
acquiesce to it in the interest of goodwill and expedience. I have agreed to chair the
committee in Kent's absence.
After review and consideration the committee makes the following observations and
conditions our approval of your application on your signed and notarized acceptance of
the stipulations noted:
0
SITE
1. That all Pitkin County Setbacks will be observed
2. That all Holland Hills at Basalt Subdivision recorded Easements will be properly
utilized, protected and restored to a grassed state as required by covenants.
3. That no encroachments will be installed in such a way as to block further utilization
of any easement.
4. That no Mercury vapor, halogen, or direct incandescent flood, the bulb of which is
visible from any public street, trail or right of way, will be utilized for outdoor
lighting. All outdoor lighting will be low level and indirect.
5. That a landscape plan, including automated irrigation system, be submitted to the
committee for review and approval. Community regulations prohibit the use of
domestic water for irrigation and mandate the use of the ditch water provided for that
purpose. The rational for this is to conserve treated water and utilize the surface
water irrigation resource for beautification and the establishment of acceptable
ground covers which will inhibit weeds and the encroachment of non-native
destructive plant species. You indicated that you intended to leave the lot in a natural
state. This is unrealistic and unacceptable in as much as there will be nothing natural
about the lot after the completion of earthmoving and construction. Culverting or
lining of the ditch will only serve to further the desertification of the property and
encourage the encroachment of noxious weeds. Covenants mandate the planting and
maintenance of vegetative groundcovers and outlaw the propagation and acceptance
of noxious weeds. We have a very valuable resource in our irrigation water rights
that other subdivisions would die for. You are paying for it in your property taxes.
Use it to your advantage and enhance your property values.
SUBDIVISION AND ROAD DISTRICT
This application calls for the moving of an existing log house, on subdivision roads, to
the site on Lot 28. Approval of this application is further conditioned on your acceptance
of the following:
1. That any damage occasioned to the subdivision roads, overhead or underground
utility infrastructure or street lighting, irrigation ditches or drainage structures and
ditches within the subdivision will be repaired to the satisfaction of the Holland Hills
Metropolitan District and the Holland Hills Homeowners Association at your
expense.
2. That the structures will not be stored on site. That means that the existing building
structures will not be moved to the site under any circumstances until the footings,
foundation walls, and load bearing walls have been erected sufficiently to allow the
buildings to be set in place immediately and without delay in a continuous operation.
BUILDINGS
3. That the project be completed in its entirety, from groundbreaking to landscaping, in
the 18 months allowed under subdivision regulations.
4. That the project be constructed according to all governing Pitkin County codes and
building and zoning regulations and that no structural, electrical or plumbing changes
will occur after the delivery of the certificate of occupancy without additional review
by the Architectural Control Committee and additional Pitkin County permits.
5. That the combined buildings be confined to one primary and one accessory dwelling
unit for a total of two dwelling units and no more.
6. That all existing windows and doors be scrapped and replaced with new windows and
doors incorporating energy efficient glass and insulation to current code.
7. That the entire roof be replaced with new roofing material, either metal or asphalt
shingle.
EXTERIOR FINISHES
8. That the entire exterior surface of the existing log buildings be stripped and refinished
to clean and expose the beauty of the natural wood beneath. Merely covering the
existing old log buildings, as you indicated in our meeting with you, with a dark solid
color stain, will not be acceptable.
9. You indicated that you wish to paint the buildings with a solid color, "special
Walnut" stain. This stain is the darkest stain in the color spectrum short of ebony
(black). Choose a semi -transparent, much lighter stain, which allows the grain and
feel of the log structure to show through and resubmit a sample of that stain. Painting
logs to hide the age of their finish and their imperfections is, as observed, "dated and
dreary" as well as a poor indicator of your unstated but surely existing desire to be a
positive addition to our neighborhood.
10. Placing an old structure made of horizontal logs on top of a new structure made of
horizontal 1 x 8 cedar siding, next to a new structure with shingles on the second
level and horizontal lx 4 cedar siding on the first level is hodgepodge and
unimaginative.. Painting both structures in their entirety in one almost solid, nearly
black color compounds the issue and is totally out of the question. These treatments
will only detract from your property value. Don't take our word for it. Ask any
licensed Architect or uncompromised Realtor for their opinion. Reconsider and
resubmit your exterior finish choices with an eye toward dissimilar treatments and
dissimilar colors between levels that will tie the two buildings together thematically
and be esthetically pleasing to the eye.
IRRIGATION DITCHES
You indicate in your application that you wish to enclose the Kester Ditch in a culvert for
the purpose of containing leakage. Discussions with the Pitkin County Environmental
Health Department indicate that your septic problems can be resolved with the
installation of a less expensive ditch lining. Polling of the contiguous neighboors and the
mo
Board members indicates a majority desire to see the ditch remain open for aesthetic and
safety reasons. Approval of this application is further conditioned on your acceptance of
the following conditions regarding the irrigation ditch:
1. That you Provide proof in writing of your approval from the Kester Ditch Company.
2. That the enclosure be accomplished by either lining the ditch for it's entire length
across your property in accordance with Pitco Environmental Health regulations and
Kester Ditch requirements regarding type, thickness, and placement methods for the
liner membrane or;
3. That the enclosure be accomplished by enclosing same in the same size, type and
manufacture of plastic or Polyvinyl culvert that currently exists where the ditch
crosses Holland Hills road at the upstream end of Lot 28.
If your choice is culvert you further agree:
4. That the culvert will be installed in accordance with manufacturer specifications and
to a depth and level that will maintain the same flow line that currently exists across
the property.
S. That the culvert will be engineered and installed in such a way that will maintain an
airspace in at least the upper 33 1/3 % of the pipe from inlet to outlet under the
maximum possible CFS flow of the Kester Ditch. This is for safety purposes in the
event that children, pets or wildlife are swept into the pipe.
6. That a cleanable permanent angled steel grate, anchored on a pivot in concrete, be
installed at the upstream entrance to the culvert sufficient to inhibit small children,
pets or wildlife from entering the culvert. The design shall be similar to the culvert
entrance on the Roaring Fork Club property further downstream on the Kester Ditch.
That the Kester Ditch Company and Holland Hills Homeowners Architectural
Control Committee exercise final approval over the design of the entrance grate.
7. That you and your heirs, successors or assigns of Lot 28 accept, by deed restriction
and in a written document filed with the Kester Ditch Company and the Holland Hills
Metro District, responsibility for perpetual maintenance and repair of the culvert and
cleaning of the steel grate entrance sufficient to avoid backup or flooding of any kind
on any public or private property in the subdivision. This document must further
state that you accept liability for any flooding occasioned by the lack of maintenance
or cleaning of the culvert or it's protective grates.
8. That you install an intermediate access point in the culvert, such as an inverted "T"
with manhole cover or protective grating sufficient to allow an individual to enter the
Pipe at or near the midpoint for cleaning and maintenance.
9. That the upstream end of the culvert begin at a point no closer than 140' downstream
from the eastern most lot comer of Lot 28.
10. That an additional "T" with protective grating be installed to pickup the lateral ditch
which extends from the Arbaney ditch, downhill along the northwest lot line of Lot
29 and the flow be directed and contained into the Kester Ditch through this tee.
Failure to do this will cause intermittent and unacceptable flooding on Lot 28 and the
properties below.
0?6
11. That the culvert backfill cover be smoothed into a natural appearing contour of the
existing slope, seeded with grass seed and irrigated with the permanently installed
irrigation system.
HOLLAND HILLS METROPOLITAN DISTRICT
Final approval is predicated on payment of the required tap fee of $5,100.00.
SPECIAL REVIEW FOR CARETAKER DWELLING UNIT
We have review your submittal to Pitkin County, Swanson CDU Special Review (PID#
2467-174-01-005 CASE# P005-03) and are submitting comments at their request. We
disagree with your responses to Section 3-210-020 General Standards and Criteria, i.e.
Sections D, E & G.2.: Based on the exterior fagade,,colors and refinishing
techniques you indicated in conversation and the elevations you provided to us.
Without revision, your project will not be in harmony with the surrounding area, and
will negatively effect the neighborhood.
Section G. I.: The public health, safety or welfare cannot be guaranteed unless you
agree to all of the stipulations regarding lining or culverting of the Kester ditch.
In summary, we cannot support your special review application without first receiving
your signed approval and agreement to all of the stipulations included herein.
This concludes our observations and stipulations. Please indicate your acceptance by
initialing each page and signing Page 6 in the presence of a Notary. Our final letter of
acceptance will be issued only upon receipt of your executed copy of this document,
satisfactory resolution of stipulations requiring further submittal, and proof of compliance
with any of the other affiliated agencies listed above or involved in the governmental
review process.
Sincerely,
Ol't"'u
Mo oe Summers, erson
Cc: Pitkin County Community Development Department
Pitkin County Environmental Health Department
Holland Hills Metropolitan District
Holland Hills Homeowners Association Board of Directors
Contiguous Property Owners
9y
C
ATTEST:
C
I (We) the Owner(s) of Lot 28
agree with and consent to be bound by all of the protective covenants, by-laws, and
articles of incorporation, either existing or promulgated by, the Board of Directors of the
Holland Hills at Basalt Subdivision Property Owners Association (HHABSPOA) and it's
Architectural Control Committee as well as the Holland Hills Metropolitan District.
I further understand and agree that in accordance with paragraph 9C. of the third
amendment to the protective covenants of the HHABSPOA:
"The HHABSPOA membership collectively and/or individually shall have the
right to prosecute any action to enforce the provisions of all of these Protective
Covenants by injunctive relief or prosecute any action for injunctive relief,
specific performance, and for damages by reason of any violation of these
Protective Covenants." And further that in accordance with paragraph 18 of the
covenants "....it shall be lawful for the HHABSPOA ..........to institute and
prosecute proceedings at law or in equity to prevent, abate or terminate such
improper uses and to recover damages or obtain such other relief as may be by
law provided. Including recovery of collection costs and reasonable attorney's
fees to the prevailing party."
I (We),
lawful and sole owner (s) of Lot No.
Street Address
the
hereby approve, execute and consent to the stipulations for approval described above.
Dated: , 20
STATE OF COLORADO )
SS.
COUNTY OF )
Subscribed and sworn to before me this day of
20� by
Witness my hand and official seal.
My Commission expires:
Notary Public
36
PITKIN ENVIRONMENTAL HEALTH DEPARTM.
ISDS DESIGN CALCULATIONS
Owner's Name
Parcel ID #
House Size (sq. ft.) (75 gpd, 100 gpd, or 130 gpd)
Number of Bedrooms in Main House
Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House
Number of Bedrooms in Detached Caretaker unit
Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit
(If the caretaker unit is ATTACHED, treat as if part of main house.)
Average Daily Waste Plow 800
State Review Required? no
Perc Rate ® (1)
Design Flow (Q) = # potential bedrooms X 2 people/bedroom X gpd X 1.75
Q= 1400
Minimum tank capacity
1750 gallons
Absorption Area (=Q/5 X SQRT perc rate)
A = 1084.4353 sq. ft. of absorption area required
70 gravelless chamber units without reduction
# of Perc Holes Required: 3
1 in every soil type? Spaced uniformly over proposed area?
QUICK 4 9_8
A = 542.21767 sq.ft. with 50% reductionlRENCHES
55 graveBess chamber units with reduction
STANDARD
A= 542.21767 sq.ft. with 50% reductionTRENcims
35 gravelless chamber units with reduction
EO 36
34 EQ36 units in TRENCHES
SETBACK FROM WELL
# of feet = 132
SETBACK FROM POND, STREAM OR IRRIGATION DITCH
# of feet = 82
SETBACK FROM DRY GULCH
# of feet = 57
31
100
QUICK 4 9.2
759.10474 sq ft 30% reduction BED
83 chamber units with reduc.
759.10474 sq ft 30% reduction BED
49 chamber units with red=.
61 EQ36 units in a BED
H116. L L PO�2664
GNnwood SpriWC081602
IN
Ph97"18.5033
Fu 303-I16.2796
May 11, 2006
Tom Misner, Inc.
Attn: Tom
PO Box 393
Basalt, Colorado 81621
Irrigation Ditch Clarification Letter, Proposed Residence
Lot 28, Holland Hills Subdivision
Holland Hills Road
Pitkin County, Colorado
Tom,
Project No. 1181
ALL SERVICE septic, LLC reviewed the onsite wastewater system plans, dated May 4, 2006,
prepared by our firm.
The irrigation ditch displayed on the OWS plans is incorrect. 21a,451chI;iea tldn:tbafa[.aide-of twieid
t4AW 1'O -6f to pwpanp The 50 -foot setback distance between the drain field and the irrigation
ditch must be maintained. A 20-mii litter can be plated in the ditch to reduce setback to 10 foot if s
All other recommendations in the report must be followed.
LIMITS:
The design is based on information submitted. If soil conditions encountered are different from
conditions described in report, ALL SERVICE septic, LLC should be notified. All OWS construction
must be according to the county regulations. Requirements not specified in this report must follow
county regulations. The installer should have documented and demonstrated knowledge of the
requirements and regulations of the county in which they are working.
Please call with questions.
Sincerely,
ALL SERVICE septic, LLC
Timothy R. Petz, P.G.
3a
flLL'p��
all r��
PhfrQ61tS033
hc30i716779f
May 4, 2006
Tom Misner, Inc.
Attn: Tom
PO Box 393
Basalt, Colorado 81621
RECEIVED
MAY 1 1 2006
PITKIN COUNTY ENVIRONMENTAL
HEALTH& NATURAL RESOURCES
Project No. 1181
Subsurface Investigation and Onsite Wastewater System Design, Proposed Residence
Lot 28, Holland Hills Subdivision
Holland Hills Road
Pitkin County, Colorado
Tom,
ALL SERVICE septic, LLC evaluated the subsurface investigation prepared by HP Geo -tech, Job No
102 754, and prepared an onsite wastewater system (OWS) design for the subject residence. The
property is located in Holland Hills, in an area where OWS are necessary. This letter is to be used in
conjunction with plans provided. Ths4oc,%L-vm r•disiri"jmvidervawa
A 4 -bedroom
approximately
ate residence. F
SITE CONDITIONS
residence is proposed as indicated on Figure 1. The property is vacant and slopes
5% to the southwest. There is a large irrigation ditch that is a+ittsted, to the north of
wA�n
,Qt WY - aiSo chi+c In v -o �C" S. Ss&s
SUBSURFACE
P'LD° P -F j� cc e Loss
HP Geo -tech investigated the subsurface by excavating ane proSle pit end holes as
indicated on attached plans. HP Geo -tech indicated the test pit has a 6 -inch topsoil layer, underlain by
sandy, silt and clay to the maximum depth explored of feel! Groundwater or bedrock was not
encountered. Percolation rates ranged from 9 t 20 minutes per inch (MPI). A 15 MPI M* will be
used to design the OWS.
DESIGN SPECIFICATIONS
The OWS design is based on 4 -bedrooms and an average sewage load of 800 GPD. The installation
must include a 2000-gmthn two partnaent, precast eon jewsaptir. aek, with the addition of a
iia 0te second campmhaent. Tank alternatives may be considered. Fete-gmvaRez& chamber
trenettestrust be-instatled as indicated ea plans provided. Fenn rows-ef-14-`Qt i 4` cha,nbers; fors
totai-e&56 chernbem, mitt 553 square feet{SF) of iefiihative area, is required. A dist9bution box and
serial overflow should be used to distribute effluent. Construction must be accomng to the county
ISDS regulations, the septic permit provided by Pitkin County Environmental Healtji Department, and
this design.
'v
33
• • OWS Design
Project No. 1181
5/04/06
Page 2
GEOLOGY
ALL SERVICE septic, LLC reviewed the local soil conditions and geology at the subject site. The
soils consisted of a 6 -inch silty, sandy root zone, underlain by silty sandy clay to the maximum depth
explored of 8 feet. Due to the silty, sandy matrix of the soils proper treatment of effluent will take
place within 4 feet of soil and effluent interface. The soils will provide adequate treatment of effluent,
hence a very low risk of onsite well contamination._
Based on geological conditions and evaluation of risk of contamination of surface water and ground
water, it is not necessary to add 8 feet additional distance for each 100 gallons of wastewater flow
over 1000 gallons per day as specified in the table to prevent contamination.
d4fcH may be redncerlm 96 feek PF �atiaer
betweem .lie"-i6serp in area—ate !hw-i*rigntien. di --is' app -0 late tw` Prevell&
-aaataminatiun. It is understood that the irrigation ditches will be lined, and hence will only be lined
within 50 feet of proposed drain field.
OPERATION INFORMATION AND MAINTENANCE
The surface of the drain field should be seeded upon completion. Vegetation is an important factor in
drain field performance. Geo -fabrics or plastics should not be used over the drain field. Livestock
should not graze on the drain field. Plumbing fixtures should be checked to ensure that no additional
water is being discharged to OWS. For Example, a running toilet or leaky faucet can discharge
hundreds of gallons of water a day and harm a drain field.
The homeowner should pump the septic tank every two years and clean the effluent filter as needed.
Garbage disposal use should be minimized, and non -biodegradable materials should not be placed
into the OWS. Grease should not be placed in household drains. Loading from a water softener
should not be discharged into the OWS. No hazardous wastes should be directed into the OWS.
Mechanical room drains should not discharge into the OWS. The OWS is engineered for domestic
waste only.
ADDITIONAL CONSTRUCTION NOTES
If design includes a pump, air release valves and weep holes should be installed to allow pump lines
to drain to minimize risk of freezing. Excavation equipment must not drive in excavation of drain
field due to the potential to compact soil. Extensions should be placed on all septic tank components
to allow access to them from existing grade. Precast concrete tanks and distribution boxes should be
used, unless plastic or fiberglass is required. Septic tank risers should extend to grade. Access to all
tank compartments and distribution devices is optimal. Easements will be encroached will the OWS
installation. The client must be aware of potential problems. We can be notified to discuss these.
INSTALLATION OBSERVATIONS
ALL SERVICE septic, LLC, and the county must view the OWS during construction. The OWS
observation should be performed before backfill, after placement of chambers and distribution pipes.
Septic tanks, distribution devices, pumps, dosing siphons, and other plumbing, as applicable, must
also be observed. ALL SERVICE septic, LLC should be notified 48 hours in advance to observe the
installation.
S61
• • OWS Design
Project No. 1181
5/04/06
Page 3
The design is based on information submitted. If soil conditions encountered are different from
conditions described in report, ALL SERVICE septic, LLC should be notified. All OWS construction
must be according to the county regulations. Requirements not specified in this report must follow
county regulations. The installer should have documented and demonstrated knowledge of the
requirements and regulations of the county in which they are working.
Please call with questions.
Sincerely,
ALL SERV:
Timothy R.
3 copies
3S
Reviewed
Richard
0
Bill Swanson
December 6, 2002
Page 4
is
runoff around the residence and garage.
4) Roof downspouts and drains should discharge well beyond the limits of
all backfill.
5) Landscaping which requires regular heavy irrigation should be located at
least 5 feet from the buildings. Consideration should be given to the use
of xeriscape to limit potential wetting due to irrigation.
Percolation Testing: Percolation tests were conducted on November 22, 2002 to
evaluate the feasibility of an infiltration septic disposal system at the site. One profile
pit and three percolation holes were dug at the locations shown on Fig. 1. The test holes
(nominal 12 inch diameter by 12 inch deep) were hand dug at the bottom of shallow
backhoe pits and were soaked with water one day prior to testing. The soils exposed in
the percolation holes are similar to those exposed in the Profile Pit shown on Fig. 2 and
consist of slightly gravelly sandy silt and clay. The percolation test holes were
protected from freezing with rigid foam insulation and were free of frost or ice at the
time of testing. The percolation test results are presented in Table H. Based on the
subsurface conditions encountered and the percolation test results, the tested area should
be suitable for a conventional infiltration septic disposal system. Pitkin County requires
.a civil engineer design the infiltration septic disposal system. Pitkin County should be
contacted for specific design requirements.
Limitations: This study has been conducted in accordance with generally accepted
geotechnical engineering principles and practices in this area at this time. We make no
warranty either expressed or implied. The conclusions and recommendations submitted
in this report are based upon the data obtained from the exploratory pits excavated at the
locations indicated on Fig. 1, the proposed type of construction and our experience in
the area. Our findings include interpolation and extrapolation of the subsurface
conditions identified at the exploratory pits and variations in the subsurface conditions
may not become evident until excavation is performed. If conditions encountered
during construction appear different from those described in this report, we should be
notified at once so re-evaluation of the recommendations may be made.
This report has been prepared for the exclusive use by our client for design purposes.
We are not responsible for technical interpretations by others of our information. As
the project evolves, we should provide continued consultation and field services during
construction to review and monitor the implementation of our recommendations, and to
verify that the recommendations have been appropriately interpreted. Significant design
changes may require additional analysis or modifications to the recommendations
H -P GEOTECH
2 CP
WORTH-PAWLAK GEOTECHNIC,, INC.
TABLE II
PERCOLATION TEST RESULTS JOB NO. 102 754
HOLE NO.
HOLE
DEPTH
(INCHES)
LENGTH OF
INTERVAL (MIN)
WATER DEPTH
AT START OF
INTERVAL
(INCHES)
WATER DEPTH
AT END OF
INTERVAL
(INCHES)
DROP IN
WATER
LEVEL
(INCHES)
AVERAGE
PERCOLATION
RATE
(MIN./INCH)
P-1
41
15
water added
7
6
1
20
6
5 1/4
314
7 1/4
6 1/2
3/4
6 112
5 314
3/4
5 3/4
5
3/4
5
41/4
3/4
P-2
42
15
water added
water added 1
B
61/4
1 3/4
15
6 1/4
5
1 1/4
7 1/4
6
1 1/4
6
5
1
5
4
1
6 112
5 1/2
1
P-3
52
15
water added
water added
water added
10
6 3/4
3 1/4
9
9 1/4
7
2 1/4
9 1/4
7 112
1 3/4
7 1/2
5 3/4
1 3/4
9 1/4
7 1/2
1 3/4
7 1/2
6
1 1/2
Note: Percolation test holes were hand dug in the bottom of backhoe pits and soaked on
November 21, 2002. Percolation tests were conducted on November 22, 2002. The
average percolation rate is based on the last two readings of each test. The holes were
protected from freezing overnight with rigid foam insulation and were free of ice and
frozen soils at the time of the test.
PIT 1 We PIT 2 PRO PIT
0
0
4'S
WC-15.0AD WC -3.3
WC -14.9 OD -94
1i
DD -109
-200-52 DD -10e 5
5 -200-49
L
Y
LL -23
wc-16.0n
R-7
a
a
W
DD 104 WC -12.1
O
00-116
L
10
10
LEGEND:
TOPSOIL; sandy silt and clay, organic, soft, moist, dark brown.
SILT AND CLAY (ML—CL); sandy to very sandy, slightly gravelly, medium stiff, moist, red.
2" Diameter hand driven liner sample.
NOTES:
1. Exploratory pits were excavated on November 21, 2002 with a backhoe.
2. Locations of exploratory pits were measured approximately by pacing from features on the site plan
provided.
3. Elevations of exploratory pits were measured by instrument level and refer to the Bench Mark shown
shown on Fig. 1.
4. The exploratory pit locations and elevations should be considered accurate only to the degree implied
by the method used.
5. The lines between materials shown on the exploratory pit logs represent the approximate boundaries
between material types and transitions may be gradual.
6. No free water was encountered in the pits at the time of excavating. Fluctuations in water level may
occur with time.
7. Laboratory Testing Results:
WC = Water Content ( % )
DO = Dry Density ( pcf )
—200 = Percent passing No. 200 sieve
LL = Liquid Limit ( % )
PI = Plasticity Index ( % )
102 754
HEPWORTH-PAWLAK
LOGS OF EXPLORATORY PITS
Fig. 2
GEOTECHNICAL, INC.
APPROXIMATE SCALE
1"=40'
`J
PIT 1
LOT 28
LOT 26
�l
I
I
■ I
PIT 2
I I
I (
I �
I PROPOSED '
I ARAGE
I /
P 11 A ■PROFILE
PI 2 PIT /
0 /
P 3 /
If
I �l
BUILDING
ENVELOPE/
EXISTING
IRRIGATION
DITCH
LOT 29
I102 754 I GEOTEOCHNICAL,N AONDAPERCOLATIONLOTEST HOLES S I Fig. 1
W
Nt7V-18-2005 15:57 HOLEOTECH
G( Ftech
HEPWORTH-PAWLAK GEOTECHNICAL
December 6, 2002
ii
LJ
Hcpu'orth•Pawlak Gcotcch„cxi, inc.
5020 Cour,' Road 154
Glenwood Spris, Colon& 8160
Phone: 970-945.7988
Fax: 970845-8454
em 0: hpgaoWh.pgcoreeh.coa:
$ill Swanson
914 Water Avenue, n17
Aspen, Colorado 81611 Job No_ 102 754
Subject: Subsoil Study for Foundation Design and Percolation Test, Proposed
Residence, Lot 23, Holland Hills, Pitkin County, Colorado
Dearivu. Swanson:
As requested, Hepworth-Pawlak Geotechnical, Inc. performed a subsoil study and
percolation test for foundation and septic disposal designs at the subject site. The study
was conducted in accordance with our agreement for bcotechnical engineering services
to you dated November 19, 2002. The data obtained and our recommendations based
on the proposed construction and subsurface conditions encountered are presented in
this report. Evaluation of potential geologic hazard impacts on the site are beyonc the
scope of this study.
Proposed Construction: The proposed residence will be a single story wood frame
structure above a walkout basement and located on the site as shown on Fig. 1. A
detached garage is proposed southeast of the residence. Ground floors are proposed to
be slab -on -grade. Cut depths are expected to range between about 3 to 8 feet_
Foundation loadings for this type of construction are assumed to be relatively, light and
typical of the proposed type of construction. The septic disposal system is proposed to
be located downhill and south of the garage.
If building conditions or foundation loadings are significantly different from those
described above, we should be notified to re-evaluate the recommendations presented in
this report.
Site Conditions: Lot 28 is located on the north side of Holland Hills Drive. The ground
surface in the building area has a moderate slope down to the south with about 4 feet of
elevation difference across the residence. The lot is vegetated with grass and weeds. An
existing irrigation ditch crosses the lot above the proposed building areas. We
understand the ditch will be piped across the site during development.
Subsurface Conditions: The subsurface conditions at the site were evaluated by
excavating two exploratory pits in the residence area and one profile pit near the garage
in the septic disposal area. The pit locations are shown on Fig. I. The logs of the pits
Parker 303.841-7119 a Colorado Springs 719.633-5562 • Silverthotne 970-458-1989
P.02/12
NOU-1e-2005 1557 H-P'UEOTECH
�
�e�
• P.01/12
'HE?WOF'ri-PAWLAK GEolECHNICAL, INU.
50;C ,^,curay Road 154
G{snwoop Sprint=. Colorado E1601
Pnone: 670-945-798E
Fax: 670-945-6454
r. -mad: hp9�o�"p9aote°h-tom
FAX TRANSMITTAL FORM
PROJECT NO-: �a
DATE: ' `
FAX NO:
r
TO: �—
FROM:
Number of Pages= tnclua g this pe9e1
MESSAGE:
The original of this transmittal will be sent by:
Ordinary Mail I
Overnight
Other '0
Fax On1Y
len rete ved this communication un error, or If
he information contained m this facsimile message is confidential and intended for the sole use o e
lease notify us at 970 -945 -7988 -
problems
rained above • If you are not the intended reoip
problems o=ur with transm ssion, p
sent
1 NOV718-2005 15:58 H--OGEOTECH • P. e3/12
Bill Swanson
December 6, 2002
Page 2
are presented on Fig. 2. The subsoils encountered, below about 1 foot of topsoil,
consist of slightly gravelly sandy silt and clay. Results of swell -consolidation testing
performed on relatively undisturbed samples of the sandy silt and clay, presented on
Figs. 3 and 4, indicate low compressibility under existing low moisture conditions and
light loading and typically low to moderate compressibility upon wetting and additional
loading. The sample from the Profile Pit showed a moderate collapse potential when
wetted under loading. No free water was observed in the pits at the tine of excavation
and the soils were moist.
Foundation Recommendations: Considering the subsoil conditions encountered in the
exploratory pits and the nature of the proposed construction, we recommend spread
footings placed on the undisturbed natural soil designed for an allowable soil bearing
pressure of 1,200 psf for support of the proposed residence. The soils tend to compress
when wetted underload and there could be some post -construction foundation
settlement. Footings should be a minimum width of 20 inches for continuous wails and
2 feet for columns. Loose and disturbed soils and any existing fill encountered at the
foundation bearing level within the excavations should be removed to expose the
undisturbed natural soils_ The, subgrade should then be moistened and compacted.
Exterior footings should be provided with adequate cover above their bearing elevations
for frost protection. Placement of footings at least 42 inches below the exterior grade is
typically used in this area. Continuous foundation walls should be reinforced top and
bottom to span local anomalies such as by assuming an unsupported length of at least
12 feet. Foundation walls acting as retaining structures should be designed to resist a
lateral earth pressure based on an equivalent fluid unit weight of at least 50 pcf for the
on-site soil as backfill.
Floor Slabs: The natural on-site soils, exclusive of topsoil, are suitable to support
lightly leaded slab -on -grade construction with a low potential for differential settlement
To reduce the effects of some differential movement, floor slabs should be separated
from all bearing walls and columns with expansion joints which allow unrestrained
vertical movement. Floor slab control joints should be used to reduce damage due to
shrinkage cracking- The requirements for joint spacing and slab reinforcement should
be established by the designer based on experience and the intended slab use. A
minimum 4 inch layer of free -draining gravel should be placed beneath basement level
slabs to facilitate drainage. This material should consist of minus 2 inch aggregate with
less than 50% passing the No. 4 sieve and less than 2% passing the No. 200 sieve.
GEOTECH
NOV-18-2005 15 58
Bill Swanson
December 6, 2002
Page 3
H 0 GEOTECH • P.04i12
All fill materials for support of floor slabs should be compacted to at least 95% of
maximum standard Proctor density at a moisture content near optimum. Required fill
can consist of the on-site soils devoid of vegetation, topsoil and oversized rock.
Underdrain System: Although free water was not encountered during our exploration,
it has been our experience in the area that local perched groundwater can develop during
times of heavy precipitation or seasonal runoff. Frozen ground during spring runoff can
create a perched condition. We recommend below -grade construction, such as retaining
walls and basement areas, be protected from wetting and hydrostatic pressure buildup
by an ut:derdrain system.
The drains should consist of drainpipe placed in the bottom of the wall backfi'U
surrounded above the invert level with free -draining granular material. The d.rain
should be placed at each level of excavation and at least 1 foot below lowest adjacent
finish grade and sloped at a minimum 1% to a suitable gravity outlet. Free -draining
granular material used in the underdrain system should contain less than 2% passing the
No. 200 sieve, less than 50% passing the No. 4 sieve and have a maximum sine of
2 inches. The drain gravel backfill should be at least 1'4 feet deep. An impervious
membrane such as 20 mil PVC should be placed beneath the drain gravel in a trough
shape and attached to the foundation wall with Masticto prevent wetting of the bearing
S0115.
Surface Drainage: The following drainage precautions should be observed during
construction and maintained at all times after the residence and garage have been
completed.
1) Inundation of the foundation excavations and underslab areas should be
avoided during construction.
2) Exterior backfill should be adjusted to near optimum moisture and
compacted to at least 95% of the maximum standard Proctor dc:asiry in
pavement and slab areas and to at least 90% of the maximum standard
Proctor density in landscape areas. Free -draining wall backfill should be
capped with about 2 feet of the on-site, finer graded soils to reduce
surface water infiltration.
3) The ground surface surrounding the exterior of the building should be
sloped to drain away from the foundation in all directions. We
recommend a minimum slope of 12 inches in the first 10 feet in unpaved
areas and a minimum slope of 3 inches in the first 10 feet in pavement
and walkway areas. A Swale may be needed uphill to direct surface
h'-? GEOTECH
N06718-2005 15:58 * GEOTECH • P.05i12
:Bill Swanson
December, 6, 2002
Page 4
runoff around the residence and garage.
4) Roof downspouts and drains should discharge well beyond the limits of
all backfill.
5) Landscaping which requires regular heavy irrigation should be located at
least 5 feet from the buildings. Consideration should be given to the use
of xeriscape to limit potential wetting due to irrigation.
Percolation Testing. percolation tests were conducted on November 22, 2062 to
evaluate the feasibility of an infiltration septic disposal system at the site. One profile
pit and three percolation holes were dug at the locations shown on Fig. 1. The test holes
(nominal 12 inch diameter by 12 inch deep) were hand dug at the bottom of shallow
backhoe pits and were soaked with water one day prior to testing. The soils exposed in
the percolation holes are similar to those exposed in the Profile Pit shown on Fig. 2 and
consist of slightly gravelly sandv silt and clay. The percolation test holes were
protected from freezing with rigid foam insulation and were free of frost or ice at the
time of testing. The percolation test results are presented in Table IL Based or, the
subsurface conditions encountered and the percolation test results, the tested area should
be suitable for a conventional infiltration septic disposal system. Pitkin County requires
.a civil engineer design the infiltration septic disposal system. Pitkin County should be
contacted for specific design requirements.
Limitations: This study has been conducted in accordance with generally accepted
geotechnical engineering principles and practices in this area at this time. We make no
warranty either expressed or implied. The conclusions and recommendations submitted
in this report are based upon the data obtained from the exploratory pits excavated at the
locations indicated on Fig. 1, the proposed type of construction and our experience in
the area. Our findings include interpolation and extrapolation of the subsurface
conditions identified at the exploratory pits and variations in the subsurface conditions
may not become evident until excavation is performed. If conditions encountered
during construction appear different from those described in this report, we should be
notified at once so re-evaluation of the recommendations may be made.
This report has been prepared for the exclusive use by our client for design purposes.
We. are not responsible for technical interpretations by others of our information. As
the project evolves, we should provide continued consultation and field services during
construction to review and monitor the implementation of our recommendations, and to
verify that the recommendations have been appropriately interpreted. Siglificant design
changes may require additional analysis or modifications to the recommendations
p -P GsorEcrt
Nt3V718-2005 1558 HIVEOTECH • P. 06/12
Bill Swanson
December 6, 2002
Page 5
Presented herein. We recommend on-site observation of excavations and foundation
bearing strata and testing of structural fill by a representative of the geotechnical
engineer.
If you have any questions or if we may be of further assistance, please let us know.
SinWely,
HEPWORTH - PAWLAK GEOTECHNICAL, INC.
Louis E. Eller
Reviewed by.
X , 222
Steven L. Pawlak, P.E. k it
LEE/ksw
attachments
cc: Boundaries Unlimited - Atm: Bruce Lewis
H -P GEOTECH
Nrxi-IR-2005 1558 *GEOTECH • P.07i12
NOtJ-1H-2005 15 59
,
P. 08/12
NOTES:
1. Exploratory pits were excavated on November 21, 2002 with a backhoe.
2 Locations of exploratory pits were measured approximately by pacing from features on the site plan
provided.
3. Elevations of exploratory pits were measured by instrument level and refer t0 the Bench Mark shown
shown on Fig. 1.
4. The exploratory pit locations and elevations should be considered accurate only to the degree implied
by the method used.
5. The lines. between materials shown on the exploratory pit logs represent the approximate boundaries
between material types and transitions may be gradual.
6. No free water was encountered in the pits at the time of excavating. Fluctuations in water level may
occur with time.
7. Laboratory Testing Results:
WC = Water Content ( R )
DD — Dry Density ( pcf )
—200 — Percent passing No. 200 sieve
LL : Liquid Limit ( % )
PI Plasticity Index ( R )
102 754 HEP WORTH—PAWLAK I LOGS OF EXPLORATORY PITS Fig. 2
GEOTECHNICAL, INC.
ti,
PIT
2 PROFILE PIT
PIT 1
0
0
m
c
4
m
p
.
WC -15.0
DD94
we=1s,o =94
DD-Ia6
X106 5
5
-200-52
_200-49
LL -23
a
t
wO-16.0
R-7
m
D0 -1o4
we -12.1
C
o
OD -116
10
10
LEGEND:
®
TOPSOIL; sandy silt and
clay, organic,
soft, moist, dark brown.
SILT AND CLAY (ML—CL);
sandy to very sandy, slightly gravelly, medium stiff, moist, red.
2" Diameter hand driven
liner sample.
NOTES:
1. Exploratory pits were excavated on November 21, 2002 with a backhoe.
2 Locations of exploratory pits were measured approximately by pacing from features on the site plan
provided.
3. Elevations of exploratory pits were measured by instrument level and refer t0 the Bench Mark shown
shown on Fig. 1.
4. The exploratory pit locations and elevations should be considered accurate only to the degree implied
by the method used.
5. The lines. between materials shown on the exploratory pit logs represent the approximate boundaries
between material types and transitions may be gradual.
6. No free water was encountered in the pits at the time of excavating. Fluctuations in water level may
occur with time.
7. Laboratory Testing Results:
WC = Water Content ( R )
DD — Dry Density ( pcf )
—200 — Percent passing No. 200 sieve
LL : Liquid Limit ( % )
PI Plasticity Index ( R )
102 754 HEP WORTH—PAWLAK I LOGS OF EXPLORATORY PITS Fig. 2
GEOTECHNICAL, INC.
ti,
NOV718-2005 15:59 GEOTECH • P.09i12
M
7
2
r
E 4
U
5
C.
0 1.
2
0
Q 3
4
moisture Content - 16.0 percent
Dry Density - 104 pct
Sample of:Sondy Silt and Cloy
From: Pit 1 at 5 Feet
No movement
upon
wetting
I
1.0 10 1
0.1 gppUED PRESSURE — kef
MEN so
Mill
No movement
IM upon
MEN 0 wetting
on
0.1 1.0
t02 754 HEP WORTH—PAWLAK
GEOTECHNICAL. INC.
Zt
00
APPuED PRESSURE — ksf
SWELL CONSOLIDATION TEST RESULTS Fig. 3
�y9
Cl
V
HEPWORTH-PAWLAK GEOTECHNICAL, mc.
TABLE 1 JOB NO. 102754 Ij
SUMMARY OF LABORATORY TEST RESULTS N
SAMPLELOCATION
NATURAL
KRYSTURC
CONTENT
('KI
NATURAL
DRY
DSITY
EN
(oNl
GRAOATNIN
PERCENT
PASSING
NC. ITA
SIEVE
ATTERRERGLIMGS__
!
UNCONTr1ED
GOMPRESSNf'
STRENGTII
IPSFr
-
FON. JR
BEDROCK TYPE
PITOCPnI
P.0
_
GRA\£L —T
M
SAND
1T4
LIQUID
LIMIT
Ixl
PLASTIC
040"
(F)
1
3
15.0
109
52
sandy silt and clay
5
16.0
104
sandy silt and clay
2
4'F.
14.9
108
49
23
7
slightly gravelly sandy silt
and clay
6%
12.1
116
sandy silt and clay
Profile
Pit
3
3.3
94
sandy silt and clay
LJ
G
m
0
m
m
It
N
.NOV-18-2905 15:59 V -P GEOTECH 14111' P. 12/12
HEPWORTH-PAWLAK GEOTECHNICAL, INC.
TABLE II
PERCOLATION TEST RESULTS
JOB NO. 102 75,e
HOLE N0. HOLE
DEPTH
(INCHES(
LENGTH OF
INTERVAL (MINI
WATER DEPTH
AT START OF
INTERVAL
(INCHES)
WATER DEPTH
AT END OF
INTERVAL
(INCHES)
DROP IN
WATER
LEVEL
(INCHES)
AVERAG
PERCOLATION
RATE
IMIN.lINCHI
P-1
I
I
'
1
li
41
is
water added
7
6
1
20
8
51/4
3/4
7 1/4
6 112
3/4
6 1/2
5 314
314
53/4
5
3/4
5
41/4
314
P.2
42
!II
I
If
15
water added
water added
8
61/4
'1 314
15
61/4
5
1 114
7 114
6
1 114
6
5
1
8
4
1
6 112
5 112
1
P.3
52
(9
i
1s
water added
water added
water added
10
63/4
3 114
9
1/4
7
2 114
9 114
7 112
'1-314
7 112
S3/4
'. 314
9 114
7 112
314
7 112
1 6
1/2
Note: Percolation test holes were hand dug in the bottom of backhoe pits and soaked on
November 21, 2002. Percolation tests were conducted on November 22, 2002. The
average percolation rate is based on the last two readings of each test. The holes were
protected from freezing overnight with rigid foam insulation and were free of ice anc
frozen soils at the time of the test.
1 BTAL P.12
\ LONGWOR
LEGEND AND NOTES
LOTT" IOtI.N
• .,,V ALB,° A 1 11 1 5 111.
P IVO. PFBN <.., I I I'll.
❑ 5..[E <, oeL.
O u V n.'. u
s ..I .NPT
m rf rf PApi .� u
..It. IA H
D] EL Ef 1.IC IA.Aa ..M .
r <fNtF LTM[
.QNT
- -.. TCH
- au l.nlNO fnvf.•II II.E
CD°Xipii`oi[a eia°Irercfx n°1mL.
X"OPEf KA VSLO F 1,159 DIM.°`I-
LN*WMf ENPULOIF 5"4( F.IENU 1. u1,'Of.TY LTM.
t
H 1 0 4 1 HAZARD REVIEW SITE P LA ��P' 3�
ITKIN
U111r1Y ASEXENf
Lot 9B
\ 9_
Ott CENTERLIMEx�
UTILITY
VRVE DELTA ANGLE RADIUS ARC TANGENT CNORD CHORD BEARING
C 1 40.47 40' 239.34 170 41' 89.00' 166.83 N 54.36 08"W
LINE BEARING DISTANCE
L I N 34.12'24'W 3 03'
L 2 5 45* 34'W IN 7.00'
LINE$ IN SPACE
LAND SURVEYS
Sa
COUNTY, COLORADO.
VICINITY MAP
SCALE: 1".2.000
'e.e':.h
1}.e: :.: }n. [ r' , ° Iran .n. '•i.�.°. .1 n. ben
.. ......... ... a:P.nr P..,n n.nil^ dl.1n 8.tl .Y
6.. 11y.r ;:i:ilb nen r..nn b• ..d q.. nF.• qr. oq • n•. °
wP <S..Y..
<:Y.r °° rAi°!:.eL �I�r .:a: •••i of 6..13. y ..P :mu °n .ler.• .IrA i. •u<A .. base
111,1.
s n. 1:11:}':1 }w .. ..3r.� a •°.°I::.i°:}r ........e.
i........ :V
}I rl :..:...I°:'P-i:°:. 1:: rn v:•p. •• }`rbi. .. yr i...n°
n .. i::::e ..:}}: •: °:.b°r:n.b.
, MA}l°i .} ..elq D ,a}." • i°o. lln b° .i n° ....d .r 11.1 .°.I
It
r°
... L.n .. W
u°} . °r 1°°.r ie' ..... .e
.
<...M d . •� .. .... rAa r...e. .i ....m ...: .d .1.11 ...
° Aq LgM.r -!<.°f RIIeI J.
V. Rd°o C..nlnr.. e r qurid bIrSOCC
D.d...... CIO; 'E u.11^.Fu R. d'a ..e Sl..d.r lr ItIT ° L. A. u u n el
Flali[..' .Fell b..•.e ° . P•P lY TL n. e. rrui -6.3.19 Prw °.d .FnW .Fell b.
<
TI, l.Il11by ..111..• u. gn......un .r. r......I
Dd.nlbl. Spu.. Y
Th A
....... iii.• .... r I..M IYdu 3A°r FS:'aa°}::'°':n:l}n•n a`i3 Ir.r ll:i:i..rin3 •1ST teen
.p< ..eb:: ::::•:: IV
.6.11 s° ......e .,rn.. .
areap e...a.a ..a w.. m..a
ao i.°r ......1 ......
hell . fill
P.,
fF......... P., U
x....-
}�...
..... }
.......
r. . .. A.. rA. ]0" ... ....r..
y; .I r . 111k. A.q°ii. }..i Wa... di..a....h Clay
F. F.rgn, .f rnhe
dl° M.
111 °Ir..er1... rr . a.a br.•A .i.A 1. rM a0 '•'�... hall h }.111.1
r3Ad
.... .an ...<..I f l.da.. 1,d• lr.. are. a r...
ee b .. e. I,.IA.. ... e. .MTI h.... 111111. a
.I .. . :°r °... °I sr° r ,e. °r ..r.. .. .... 1°ee°.
ud. n . • °•P .yen •n n°.. rM q.<uq gr.41u .
i r:•<}i.yA }e^ .b.� lana 1.i °e:: 111 °d ..l ..
a .non b° ia...°°e .11
1. .h:ll a°•.....i .1 .n. n..[r u... .h.11 b.
A, 1.} e°:I.:ii• :" n,. ., ., K
i°"X1e <.°°i:..a ............1
.A.
n... I ... I DAVIS. °.a Er r.<li.. R°1 .n°.....
era... lure It ..r.:.{iP1::°:`:dei d.11 .,.. •m a 1,1}::.l d r W..e
:. r° I::i:°:Mlii. .✓ r.e .. A A PI......r3 L °.a y .. .•<I. < :i*, sIY .
Reil:°I I. n° l.noa}°nli 1;1111. cad° : < 1 n '!Os p I. s..°.° x.°°.e o}:ib°
.TA
r°:°CI.... rsa s•.N IY M.'...b....b 1. :.}.. .F. 11 A. el -h-,
.lab ..r.... e< ... lat ., A.3r•
•1.1..A..g3.. a. .r I •° fr. rile a.A.< ..... ..d r .I •°(, -
.b..r.bl..°1. 1.} °`.::i .A.:... I. P. •. i :..a nq• ..
.i... r 1x ped .. r.•„r.e ..1.., r3�f.
II V....el • ru<r < .1 non <..bu.r.br..°r.r..l. °N
.n.,.n.e . . a..... Y°:::::31st° ....... °
<Lar i. xM .ee.MA °°I •n ^h wl.<u rAu Is[•In.r. . h a va I
°f
Clea. uy °r Iain ..... °b... .n. rsa l'}°i v::x.: P•I°. .. p-NITn°dl.
:t nI1.d • •.d br IF. n r :.P°B..Idlnq Cad°
h...
..e .1.1... a...I LN'. :. iv.
yl war. id A. ...I Luq, esw .n91 .1. .• .e.n
q mblIulu
•pallled Y.ry.nd by 'A. IIn W.•hal plu 1° 11611 nlr.! bu ltl.n...
".Prliea l.. r Ir. r •lent are . n
Von .n°II ..
S.rre4rn MII ug1Y u F .ry t°.aY npruo.0 ...xln�Ae.' .p lnLlu
..... ..i ° f°1x1° °11•.11" 1., •. "A.11 b. b... ..... .I 1.b- ..ed
.yo . °: <
L� i°•r° d J:u i" [q.1:�..:; :}; .1,.A °.e ....ybl Jahr.
•.. ;l° .... eri.a rel° A°.} be er °. °e ..
..........
°•r•e `.d .n ..:h. rh 10 °I.r... n•Y.hell°O:..re...d �. ° high
••iq i:: Bry .Aal h r al.d na ry.°od In .° .pr•• d .........
e
° n... M[A .6. ° e°.i. °.e
:::r . i.»`u./ .d 3:}°"::31....... ; ::1.... .. e
:i1"Ay . i ... i..........a ...II 6.}; i:: <
.tn ...e r.. x -A... .,.*.I
f° -r...... IT
i; f.:F r.e .. Mn h.o ° onbr. d . "•IO IbO:AC lv.. r..qu nae
b.°:}.e .. i, x' .
In °P•:i.<. L. .e, .<[
nl w. .rll ler 11 n. .nal
it. b°.i.d. >
'.. ., ier<} M,1: sip. }.el, : .I, 1,.. 611.1'. puuilil . l.ppio sill nl..d le Ih 1. Pr °p.ny
° y r .r 11.1 '1 q. ,
a...1. ° ... . At.. .... <. °I s.
i..., .. ..b.}..f.. d ..y .. bv.l3i:y°} ... sees y..... `e.M1.n .nb°'. .
....... r Ir.. o or .r y'ly.0 Lyud .. .NOePe.as.I .e. •Irll
e:.... r..o 1P° V. ...::3'i. '3.....d na ° ..r ren rn..... , n....a 1 $ .n.
.ha. M . . OI Ii. r. a°a .ler.. •Y •°.3.1,163 'i1 ..:.......'A° ` li.[:LO1� •F 1 .I.
..r. y..... 3....•. AIF ... L..i.r..... <:ro ... .ye..
SEC. 17. T.8 S.,
R.86 W., 6th P.M.
N
W + E
S
SCALE: I".20'
CONTOUR INTERVAL: 2'-0"
LEGAL DESCRIPTION
LOT 28. rWLL.<ND HILLS AT B.SAI1 1111111 COUNTY. COLORADO
DISCLAIMER
I1041 MPROVEMENTS SAND THE HAZARD
UYE AND OCCUPANCYxAI TXEREOET AFFECT ME PROPERTY All'
WAIVER
THE PROMSIONS OF THESE REOULATI ONS DO NOT IN A2Y WAY ASSUR£ 0R IMPLY IIInI
AREA OUTSIDE OF DE5I GNATED HAZARD AREAS WILL yE FREE FROM HPZARDY. OR
I HAT APPROVED A IIGA1ION NEASUR E5 WILL GUARANTEE SY Y OF ANY
PRO PEN
Gc
OWNER LONGWOR iN �
COMMUNITY DEVELOPMENT DIRECTOR APPROVAL
IXIY 0<1 XAZARO REVIEW 51TE PLAN FOR LONGRORTH HAS BEEN
REV IEREO AMD APPROVED 01 THE P IMIX COUNTY COWUNI TY DE VELOPNENT DIRECTOR
OFFICER TNIS (RnAAY OF � P00f MK
NT AC iBylY
PiTn rn COU YY � uA/FRwsB'Y nB✓EdPPMtNr AiR�.Q
POu�•�
'AD 711A7•rW-oICEa$
ACCEPTANCE FOR RECORDING
THIS 1041 HAZARD REVIEW SITE ?LAM HAS BEEN ACCEPTED FOR
PFIONGIN THE
OflgAlxECLERK 300VFPLIITOCEDO1Bx
�TIfA.D. IXBOOK AS RECEPTION
V AND WEC DE
ISN®IDA. jU 1, o .,
Be
(LS 1411
LRWVT
S%
0 0
;
_
§ �
§
o
<0
f
°o �
$
�
N -M.
|
-
�
§
■.
�
,
�
7
|
|�
-
k�
°
%
.
: §
�
,
|
.
\
���.....,..
�i����Il
|
p
` §
\
M
||
MZM
| |
}
w
.z
: ,
gym,
@
|;/
)
;
..�{
.
0
0
Pitkin County Environmental Health Department
Permit for an Individual Sewage Disposal System
0405 Castle Creek Road, Suite 10, Aspen, Colorado 81611
Phone 970-920-5070 / FAX 970-920-5077
Permit# 03002 Parcel ID# 2467-174-01-005
Type of permit New( X ) Repair( ) Addition/Remodel to House( )
Name of Owner William Swanson, Jr.
Street Address Holland Hills Drive, B
Property legal description Lot
Size of lot .66
Water source Public Water System
# of bedrooms in house
Caretaker unit Detached
# of bedrooms in caretaker unit
Designed for what # rooms (list)
Designed by
CO lwoS1 S
. Holland Hills
Total square footage of the house
2390
# of offices, lofts & similar sized rooms in house
Total square footage of the caretaker unit
700
# of offices, lofts & similar sized rooms in caretaker unit
FOUR: 3 BR's in main house and 1 in a proposed caretaker unit
Boundaries Unlimited, Inc.
Permit information
Mailing Address 923 Cooper Avenue, Suite. 102, Glenwood Springs, CO 81601
Perc rate 20 Profile hole depth 8ft Depth to groundwater or bedrock
Minimum Septic tank capacity 1640 gal. minimum Minimum Absorption area
:. usiTiid�ifC?
Need to reconfirm
1174 so ft
This septic permit is approved per compliance with the engineer design and specifications stamped 1/16/03. Any
changes must be approved by this department and the design engineer prior to them being made. Minimum
horizontal distances between components of the system and physical features shall conform to the Pitkin County
ISDS regulations. Before there is water in the irrigation ditches in the spring, the ditch is to be lined or piped
the length that does not meet the 75 ft setback required from the absorption area. This department shall be
called for an inspection of this work. Then the department is to be called to check the depth to groundwater
during the period of spring runoff/high ground water to insure that there is no subsurface ground water. If
groundwater is found above an 8 ft depth, this permit is not valid.
The engineer design is for a minimum 1750 gallon water tight two-compartment tank with an effluent filter. The
effluent is split two ways each to two sets of gravelles chamber trenches in series (each set has a total of 20
chambers for a total of 40 chambers.)
This department does not endorse any brand of products. This permit must be kept on-site during installation.
The engineer must do a final inspection of the installation and submit an as -built letter to this department. This
department must also be called for an inspection with a minimum of 48 hours advanced notice.
Permit approved by: +. Date: 2 3
Plans and specifications of the prop sed individual sewage disposal system have been reviewed and are considered
satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin
County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was
issued unless system construction has commenced or an extension has been approved in writing by the Department.
As -built drawings must be included with this permit before the final approval will be issued.
Installer:
Final approval: Date:
PITKIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM
0405 Castle Creek Road, Suite 10, Aspen Colorado 81611
Phone 970-920-5070/Fax 970-920-5077
Primary Contact Person (/all communication regarding this permit will go through this Person)
Name m Y/jjp
Company
Contact Mailing Address /xkr/—exi�5 lk7&—
City, State, Zip / / Business Phone :
Cell Phone:AV-,6W3 Fax : 9 - - S/$ 3 3 E mal Addrasa: ��• S
Parcel ID p (available from assessor's office
at 920-5160 or at www.oitkinassess Z
or.org )
Street address of propertf1D51-5/-A//Q'o/
Legal Description: Lot �$ ,Block ,Filing Z Subdivision /Y(oi/ovr f
Size of lot: _� �� acres. Type of proposed sWcture: (eoyr; 8ti
Total square feet of house ZrLWO Of of bedrooms (potential) In house 3
Caretaker Unit: Attached ( ) Detached ( Y, )
of caretaker
Permit is for New Home (/y
Repair due to failure ( )
Remodel/Addition ( )
Emergency use ( )
Water: Private well ( ) Spring (
) Stream ( ) Community/Public
Water S'y/stem ( )
If community system: Name of system
` /
k1011akr Ax'/8�l�ln
CQ /' (-o✓i 0.1sTC;
/-
p�
The fee for a ISDS application is $330 for a permit that takes 6 hours or less for the department to approve. If approval takes
longer than 6 hours, a rate of $65 per hour will be charged. The maximum fee is $1000. The basic fee of $330 is due at the time
of application. The remainder, if any, will be due in two stages: first, at the time of issuance of the ISDS permit; second, before
final approval of the ISDS permit.
Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information is true and
accurate and that I have provided true and accurate information on locations of all existing and proposed wells, contour
intervals, buildings, property lines, ditches, slopes, waterlines, springs, suction or irrigation (Ines, drinking water cisterns, drain
tiles, irrigation ditches, lakes, water courses, streams, Floodplain, dry gulches, and existing septic systems. I hereby certify
that any such features not shown on attached site map are not present. Issuance of the permit does not imply the approval of
any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all
approvals and permils have been obtained.
The Aspen/Pitkin Environmental Health Department, Pitkin County and employees of these agencies will be held harmless
should the individual sewage disposal system fail or malfunction. The permit to constnr is issued on Information submitted by
the applicant or his/her representatives. The owner assumes full responsibilll r se failure of the system.
Signature of appl' Date 2—
Received by Receipt #_ Date ,G2��
G:lisdsUsdsappUsd .riot
RECEIVED TIME OCT.30. 2:56AM
M
sfiQ.k�L b4 ,
f
Pitkin County Environmental Health Department
Contact Log Sheet
0 0
®
..
. .
ewr�
W.
--
V. 12 M V... P�. VAMI
w■■
���VM
�■fi1111111=
, A
MM
VMS
OR—
M WIN
MI
Fr
wWilliamDevelopment
■Construction,
■Dan
:.
&
Inc.
Finn
Vice President
.',�ftCHSTSUITE106 89"
,.8161t
.ter■■
HEMPSTEAD surrE 2n
HOUSTON, TEXAS 77M
TomMisner■
artist in metals - aesign A fabrication
■■
�t
0 0
SCALE
1.=20,
NORTH
.f
u,
2000-GALLON,y`
TWO-COMPARTMENT PRECAST0,
CONCRETE SEPTIC TANK, WITH \.,
EFFLUENT FILTER ON OUTLET `'•
,\
r / 4 `.IVu SE LI#�1``
4" PVC EFFLUENT LINE ' �. '
\ &, ' CL T k \ \
DISTRIBUTION RIBUTION BOX `\
-I
I \
< 6 ml
3 `4
553 SF OF INFILTRATIVE AREA IN 10, mjn \ ;
GRAVELLESS TRENCHES. EACH TRENCH
MUST HAVE 14'QUICK-4' CHAMBERS.
4" PVC OVERFLOW LINES \"
4" OBSERVATION PORTS _
ALL DITCHES MUST BE
LINED WITH 20 MIL PVC
WITHIN 50' OF DRAIN FIELD
THE LOCATION OF EXISTING AND PROPOSED
IMPROVEMENTS SHOWN ARE NOT THE RESULT OF A
PROPERTY SURVEY. THE LOCATIONS ARE APPROXIMATE,
IT IS THE HOMEOWNERS DUTY TO ENSURE ALL
CONSTRUCTION AND IMPROVEMENTS LOCATIONS ARE
ACCURATE. ALL SETBACK DISTANCES SHOULD BE
R -IF CONFIRMED PRIOR TO EXCAVATION.
MAY 1 6 2006
PITKIN COUNTY ENVIRONMENTAL
HEALTH& NATURAL RESOURCES
IRRIGATION DITCH
ALL SERVICE septic, LLC �Ly T 28,/�HOLLAND HILLS
�SUBDIVISION
�UBDI IS N
GLENWOPO BOX 844 PI COUNTY, COLORADO
GLENWOOD SPRINGS, CO 81602
970-618-5033 0
ROP�SED RESlDENGE
COrnpartl'n nt Septic Tank with 4" Dia. Blotuble
Effluent Filter
PVC or Concrete Rivas will, Crofnmel(s)
(bond to tank adapter with
recommended adhesive)
ndhesrve)�
ZA,I
e Ground
From Risers
" " Conduit to
± '... Alarm Pone1
Cana_uit
Inlet Tae ^— ,.•••-• ,_-„_„_,_.,,,,,,__......�
i_ ....... ...._._.,_- ......
__._.._.._--_..__.„.__ ...___..._-.
t L
Liquid Level I
I
i High Level
lilt [ Norm Float
( (optional)
IWC Splice Boz wAOrd Grips
Fiberglass Gaskeled Lid with
^� Stainless Steel Bolts
/'---- Filter Cartridge Handle
(field cut to deferea height)
Tank Adapter (Cost or bolted)
..--_.—Vent Orifice,
”) Cffluent Discharge
_._ ..,. Modulating pleaharga orlftae6
-•--•—Voull Inlet Parts
Orenco Systemsa'
InmrPcrated
814 AIRWAY AVENUE
5UTHERLIN, OREGON
97479-9012
TELEPHONE;
(541) 459-4449
FACSIMILE,:
(541) 459-2884
TANK
SPECIFICATIONS rifler Carh,;dge
.__Cffluent I"iher
CAPACITY REQUIRED = q X 1,75 X (SO HOURS/24 HOURS) =1750 GALLONS
REQUIRED TANK(S) = 2000 -GALLON, TWO-COMPARTMENT, CONCRETE SEPTIC TANK WITH AN EFFLUENT FILTER IN THE SECOND COMPARTMENT.
AN ALARM IS OPTIONAL
TYPICAL PLAN VIEW - N.T.S.
CONCRETE DISTRIBUTION
BOX WITH BAFFLE
4" PVC EFFLUENT
LINES
6' MIN.
SERIAL OVERFLOW LINES
TO ADDITIONAL 2
OBSERVATION/VENT PIPES (TYP.) TRENCHES
INFILTRATOt(...{UIK(TM) —.._._..-.__i_
CHAMBERS, 3' X 4' QUICK4(TM)
END CAPS
CROSS SECTION OF TYPICAL CHAMBER -TRENCHES
- 4" SDR 35 PVC
OBSERVATION/VENT
PIPE WITH CAP BACKFILL
SLOPE
I SLOPE FOR
V MAX
jam,... ............. 61 MIN. — --
1J 2' MIN
INFILTRATOR(R)
-EXTENT OF QUICK4(TM)
EXCAVATION CHAMBER, 3'X 4'
TRENCHES MUST BE LEVEL SCARIFY SURFACE
NOTES:
TRENCHES MUST BE ANGLED TO FIT TOPOGRAPHY AND TO
MINIMIZE REMOVAL OF EXISTING VEGETATION. INFILTRATOR(R)
QUICK4(TM) CHAMBERS ARE CONSTRUCTED WITH A PIVOT
POINTS FOR THIS PURPOSE.
THE SLOPE AT THE PROPOSED DRAIN FIELD 1S APPROXIMATELY 5% TO
THE. SOUTHWEST. VEGETATION CONSISTS OF A FULL COVER OF
NATIVE GRASSES.
LIMITATIONS • THESE PLANS MUST BE USED IN CONJUNCTION WITH
LETTER AND SOILS DATA FORM PROVIDED. THE DESIGN IS BASED UPON
INFORMATION SUBMITTED. IF SOIL CONDITIONS ENCOUNTERED ARE
DIFFERENT FROM CONDITIONS DESCRIBED IN REPORT, ALL SERVICE
SEPTIC L.L.C. SHOULD Be NOTIFIED. ALL OWS CONSTRUCTION MUST BE
ACCORDING TO COUNTY REGULATIONS, THE INSTALLER SHOULD HAVE
DEMONSTRATED KNOWLEDGE OF THE REQUIREMENTS AND REGULATIONS
OF THE COUNTY IN WHICH THEY ARE WORKING. THE COUNTY AND ALL
FVICE SPT1C L_ Mµ� ,C,MUS-1- VIEW INSTALLATION
INFILTRATOR(R) QUICK4(TM) CUT SHEET
46"
} ? (EFFECTIVE LEND-nq)
34" --- s
I
DESIGN
4-BEDR00M RESIDENCE, <6000 SF =100 GALLONS PER DAY
TOTAL LOADING = q =800 GALLONS PER DAY
PERCOLATION RATE = 15 MINUTES PER INCH
CALCULATED AREA;;; ((1.75 X q) X sgrt 15)15 = 1085 SF
REDUCTION OF 50% = 543 SF
TRENCH SPECIFICATIONS
WIDTH OF TRENCHES = 3 FEET = 1 CHAMBER
LENGTH OF TRENCHES = 56 FEET = 14 CHAMBERS
TOTAL NUMBER OF CHAMBERS - 56
TOTAL PROPOSED INFILTRATIVE AREA =553 SF
FOUR TOTAL TRENCHES
ONSITE WASTEWATER SYSTEM DESIGN
Project No. 1181
05-04-06
1�
;I
COrnpartl'n nt Septic Tank with 4" Dia. Blotuble
Effluent Filter
PVC or Concrete Rivas will, Crofnmel(s)
(bond to tank adapter with
recommended adhesive)
ndhesrve)�
ZA,I
e Ground
From Risers
" " Conduit to
± '... Alarm Pone1
Cana_uit
Inlet Tae ^— ,.•••-• ,_-„_„_,_.,,,,,,__......�
i_ ....... ...._._.,_- ......
__._.._.._--_..__.„.__ ...___..._-.
t L
Liquid Level I
I
i High Level
lilt [ Norm Float
( (optional)
IWC Splice Boz wAOrd Grips
Fiberglass Gaskeled Lid with
^� Stainless Steel Bolts
/'---- Filter Cartridge Handle
(field cut to deferea height)
Tank Adapter (Cost or bolted)
..--_.—Vent Orifice,
”) Cffluent Discharge
_._ ..,. Modulating pleaharga orlftae6
-•--•—Voull Inlet Parts
Orenco Systemsa'
InmrPcrated
814 AIRWAY AVENUE
5UTHERLIN, OREGON
97479-9012
TELEPHONE;
(541) 459-4449
FACSIMILE,:
(541) 459-2884
TANK
SPECIFICATIONS rifler Carh,;dge
.__Cffluent I"iher
CAPACITY REQUIRED = q X 1,75 X (SO HOURS/24 HOURS) =1750 GALLONS
REQUIRED TANK(S) = 2000 -GALLON, TWO-COMPARTMENT, CONCRETE SEPTIC TANK WITH AN EFFLUENT FILTER IN THE SECOND COMPARTMENT.
AN ALARM IS OPTIONAL
TYPICAL PLAN VIEW - N.T.S.
CONCRETE DISTRIBUTION
BOX WITH BAFFLE
4" PVC EFFLUENT
LINES
6' MIN.
SERIAL OVERFLOW LINES
TO ADDITIONAL 2
OBSERVATION/VENT PIPES (TYP.) TRENCHES
INFILTRATOt(...{UIK(TM) —.._._..-.__i_
CHAMBERS, 3' X 4' QUICK4(TM)
END CAPS
CROSS SECTION OF TYPICAL CHAMBER -TRENCHES
- 4" SDR 35 PVC
OBSERVATION/VENT
PIPE WITH CAP BACKFILL
SLOPE
I SLOPE FOR
V MAX
jam,... ............. 61 MIN. — --
1J 2' MIN
INFILTRATOR(R)
-EXTENT OF QUICK4(TM)
EXCAVATION CHAMBER, 3'X 4'
TRENCHES MUST BE LEVEL SCARIFY SURFACE
NOTES:
TRENCHES MUST BE ANGLED TO FIT TOPOGRAPHY AND TO
MINIMIZE REMOVAL OF EXISTING VEGETATION. INFILTRATOR(R)
QUICK4(TM) CHAMBERS ARE CONSTRUCTED WITH A PIVOT
POINTS FOR THIS PURPOSE.
THE SLOPE AT THE PROPOSED DRAIN FIELD 1S APPROXIMATELY 5% TO
THE. SOUTHWEST. VEGETATION CONSISTS OF A FULL COVER OF
NATIVE GRASSES.
LIMITATIONS • THESE PLANS MUST BE USED IN CONJUNCTION WITH
LETTER AND SOILS DATA FORM PROVIDED. THE DESIGN IS BASED UPON
INFORMATION SUBMITTED. IF SOIL CONDITIONS ENCOUNTERED ARE
DIFFERENT FROM CONDITIONS DESCRIBED IN REPORT, ALL SERVICE
SEPTIC L.L.C. SHOULD Be NOTIFIED. ALL OWS CONSTRUCTION MUST BE
ACCORDING TO COUNTY REGULATIONS, THE INSTALLER SHOULD HAVE
DEMONSTRATED KNOWLEDGE OF THE REQUIREMENTS AND REGULATIONS
OF THE COUNTY IN WHICH THEY ARE WORKING. THE COUNTY AND ALL
FVICE SPT1C L_ Mµ� ,C,MUS-1- VIEW INSTALLATION
INFILTRATOR(R) QUICK4(TM) CUT SHEET
46"
} ? (EFFECTIVE LEND-nq)
34" --- s
I
DESIGN
4-BEDR00M RESIDENCE, <6000 SF =100 GALLONS PER DAY
TOTAL LOADING = q =800 GALLONS PER DAY
PERCOLATION RATE = 15 MINUTES PER INCH
CALCULATED AREA;;; ((1.75 X q) X sgrt 15)15 = 1085 SF
REDUCTION OF 50% = 543 SF
TRENCH SPECIFICATIONS
WIDTH OF TRENCHES = 3 FEET = 1 CHAMBER
LENGTH OF TRENCHES = 56 FEET = 14 CHAMBERS
TOTAL NUMBER OF CHAMBERS - 56
TOTAL PROPOSED INFILTRATIVE AREA =553 SF
FOUR TOTAL TRENCHES
ONSITE WASTEWATER SYSTEM DESIGN
Project No. 1181
05-04-06
PROJECT NAME
N11SNaF?/LCUNGwCORTH
DRAWING TITLE
»,1
RAWING NO.
A.2.1