Loading...
HomeMy WebLinkAboutpitkin.eh.246725200590 (2004)(Barn/CDU)Document Layout (From Most Recent to Oldest Permit) Permit Application Log Sheet/Notes & Photos Communications As -built Design Engineer Design Soil Information Water Permit & Information Second System on property Third System etc. Floor Plans Please See Building and Land Use Approvals Files for additional information. 0 4 Pitkin County Environmental Health Department Permit for an Individual Sewage Disposal System 0405 Castle Creek Road, Suite 10, Aspen, Colorado 81611 Phone 970-920-5070 / FAX 970-920-5077 Permit # 4091 Parcel ID # 2467-252-00-590 Type of permit New(X ) Repair( ) Addition/Remodel to House( ) BARN w/ Caretaker Name of Owner Barry Wehmiller Group/Last Chance Ranch Street Address 1703 Lower River Road (formerly 300 East River Road) Property legal description Lot 11 River Valley Ranch Size of lot 27 acres Total square footage of the house 2,250 Barn Water source # of bedrooms in house # of offices, lofts & similar sized rooms in house Caretaker unit Total square footage of the caretaker unit 871 sq ft # of bedrooms in caretaker unit 1 # of offices, lofts & similar sized rooms in caretaker unit Designed for what # rooms (list) 4 horse stalls+ toilet/sink for 6 employees+ 2 bedroom caretaker unit Permit information Designed by Church & Associates Mailing Address 4501 Wadsworth Boulevard, Wheat Ridge, CO 80033 Perc rate 24 Profile hole depth 8 ft Depth to groundwater or bedrock >8 ft Minimum Septic tank capacity 1488 gallons Minimum Absorption area 1166 sq ft Septic permit approved per compliance with the engineer design and specifications dated October 27, 2004. Any changes must be approved by this department and the design engineer 21i2l to them being made. Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin County ISDS regulations. Design is for one 2000 gallon, two compartment concrete septic tank with a Biotube pump vault in the second compartment. There are five trenches of Infiltrator Quick4 t chambers, each trench 12 chambers long for a total of 60 chambers. This department does not endorse any brand of products. This permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an as -built letter to this department. This department must also be called for an inspection with a minimum of 48 hours advanced notice. 'Revegetation over the area of the field is very important for the functioning of the system. Pitkin County has guidelines that must be followed to assure the plants that are introduced are appropriate for the conditions of the area. The use of native plants is strongly Permit approved by: Date: l Plans and specifications of the proposed individual sewage disposal system have been reviewed and are considered satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was issued unless system construction has commenced or an extension has been approved in writing by the Department. As -built drawings must be included with this permit before the final approval will be issued. Installer: SL"', Lr ._, z _ G� �� `-/✓-.-� L Fit approval: d� c� CiL ����„c� Date: a— OS M ft PITKIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM 0405 Castle Creek Road, Suite 10, Aspen Colorado 81611 Phone (970) 920-5070 Fax (970) 920-5077 Name of OWNER q - V✓k r /le, Gn/f n CC Ranch Owner's Mailing Address 90,20 0/v City, State, Zi / v / C 3 /0s Business Phones Home Phone: E-mail Address: J Primary Contact Person (all communication regarding this permit will go through this person) Name ni L/ -rt I / Company r C rA Contact Mailing Address o t La h City, State, Zi A r"' Co /` / / Business Phone: Cell Phone: j j y �k Fax: ), — 6 a E-mail Address: Parcel ID # (available from assessor's office at 920-5160 or at www.oitkinassessor.org) Street address of property /7'OJ —vwe, lC/v"� K-( ( yUrr�tRfv ,Spo to Legal Description: Lot ,Block Filing Subdivision Ver Size of lot: i_— acres. Type of proposed structure: pg r /t h Total square feet of 4R � SV # of bedrooms (potential) in house Caretaker Unit: Attached ( ) Detached ( ) Total area(sq, ft.) of caretaker unit # of bedrooms (potential) in caretaker unit Permit is for: New Home (✓< Repair due to failure ( ) Remodel/Addition ( ) Emergency use ( ) Water: Private well (, <,Spring ( ) Stream ( ) Community/Public Water System ( ) If community system: Name of system The fee for a ISDS application is $600 for a permit that takes 6 hours or less for the department to approve. If approval takes longer than 6 hours, a rate of $100 per hour will be charged. The maximum fee is $1000. The basic fee of $600 is due at the time of application. The remainder, if any, will be due in two stages: first, at the time of issuance of the ISDS permit; second, before final approval of the ISDS permit. Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information is true and accurate and that I have provided true and accurate information on locations of all existing and proposed wells, contour intervals, buildings, property lines, ditches, slopes, waterlines, springs, suction or irrigation lines, drinking water cisterns, drain tiles, irrigation ditches, lakes, water courses, streams, floodplains, dry gulches, and existing septic systems. I hereby certify that any such features not shown on attached site map are not present. Issuance of the permit does not imply the approval of any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all approvals and permits have been obtained. The Pitkin County Environmental Health Department, Pitkin County and employees of these agencies will be held harmless should the individual sewage disposal system fail or malfunction. The permit to construct is issued on information submitted by the applicant or his/her representatives. The owner a s f II r onsibility i e of failure of the system. Signature of applicant Q t ! Date Received by Receipto� Date J s GNsdslisds appli6isdsapp Rev050103.doc �' Name: V ParcelID#: Pitkin County Environmental Health Department Contact Log Sheet Comments / Action to be Taken 1 GL 0 0 PITKIN COUNTY ENVIRONMENTAL HEALTH & NATURAL RESOURCES DATE: 16 IS I OS Send to:—\al% !- 'vrvl� Fax Number: 9,, - 6'% -6 CC: 3A,-Vo�A -� As��A6-1� CC Fax Number: From: A \ C �&�/] �Z Phone Number: qab _SD- -7 Number of Pages, Including Cover: ❑ URGENT ❑ REPLY ASAP ❑ PLEASE COMMENT ❑ PLEASE REVIEW H FOR YOUR INFORMATION COMMENTS: VNOL'SL" Pitkin County Environmental Health and Natural Resources 0405 Castle Creek Road Suite #10, Aspen, CO 81611 Phone (970) 920.5070 1 Fax (970) 920.5077 Web site www.aspenpitkin.com/depts/12/ 41 i 0 CHURCH & Associates. Inc. ENGINEERS & GEOLOGISTS December 20, 2004 Michael Fuller do Bob Chapman 23400 Two Rivers Road Basalt, Colorado 81621 Subject: Installation Observation, Proposed Fuller Barn Tract 11, Aspen River Valley Ranch Subdivision RECEIVED Last Chance Ranch Pitkin County, Colorado Job No. 16085W Mr. Fuller, JUL 2 9 2005 PITKIN COUNTY ENVIRONMENTAL HEALTH As requested, we observed the installation of the onsite wastewater system for the subject site on Novem- ber 19, 2004. The system was designed under our Job No. 16085W, last revised October 27, 2004. The system includes the installation of a 2000 -gallon, two-compartment, concrete septic tank with a pump in a Biotube® pump vault and a gravelless chamber -trench drain field. The drain field was installed in four trenches, each with one row of 15 Infiltrator® Quick4TM chambers for a total of 60 chambers and 588 i12 of infiltrative area. A concrete distribution box was installed to distribute effluent to the drain field. An as - built drawing is included as Figure 1. The components of the OW S design were installed in conformance with our plans and specifications. Final electrical connections must be made by a licensed electrician. The construction foreman may activate the pumping system at his discretion. If there are questions or if we may be of further service, please call. CHURCH & Associates, Inc. Eric R. Burns Field Technician EOC/erb 3 copies sent, via Priority Mail Copy to PCEHD, Attn: Nancy MacKenzie Copy to Byrnes & Associates, Attn: Tim Byrnes, 90 Clay Lane, Aspen, Colorado 81611 _ DENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 80033 www.goo-church.com S 303.463.9317 Fax: 303.463.9321 Toll Free -1.877.248.3123 ±25.56 AC S TRACT 11 , -kormz.14 RIVER VALLEY RANCH SUBDIVISION LAST CHANCE RA - H PITKIN COUNTY, COLORADO \ \ , \ 588 SF OF INFILTRATIVE AREA IN FOUR INFILTRATOR(TM) QUICK4(R) GRAVELLESS \ CHAMBER -TRENCHES. EACH TRENCH HAS ONE ROW OF 15 CHAMBERS FOR A TOTAL OF 60 CHAMBERS.---�, / i SCALE . 1"=20' R •1 2000 -GALLON, TWO-COMPARTMENT, CONCRETE SEPTIC TANK WITH A/ BIOTUBE(R) PUMP VAULT IN \\ THE SECOND COMPARTMENT. y\100, o ' \ 2' 'PURE CORE' / PR SED BARN WITH \ \ 4 HORSE STALLS \ \\ AND I -BEDROOM \ APARTMENT 4' SEWER LINE WITH CLE EXISTING WELL JOB NO. 16085W AS -BUILT DRAWIN/ 12/20/04 FIGURE 1 PIT'KIN ENVIRONMENTAL HEALTH DEPARTMENT• ISDS DESIGN CALCULATIONS QUICK 4 SIZING Owner's Name Parcel ID # House Size (sq. ft.) (75 gpd, 100 gpd, or 130 gpd) Number of Bedrooms in Main House Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House Number of Bedrooms in Detached Caretaker unit Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit (If the caretaker unit is ATTACHED, treat as if part of main house.) Average Daily Waste Flow 680 State Review Required? no Perc Rate � (T) Design Flow (Q) = # potential bedrooms X 2 people/ bedroom X gpd X 1.75 Q= 1190 Minimum tank capacity 1487.5 gallons Absorption Area (=Q/5 X SQRT perc rate) A = 1165.9571 sq. ft. of absorption area required 75 gravelless chamber units without reduction # of Perc Holes Required: 3 1 in every soil type? Spaced uniformly over proposed area? A maximum: 50% only if the lot size and soil conditions are optimal. If a reduction is being proposed, describe why lot size and soil conditions are optimal: QUICK q_gUSl ICh4 92 A = 582.97856 sq.ft with 50% reductioniRENCHES 816.16998 sq ft 30% reduction BED 59 gravelless chamber units with reduction 89 chamber units with reduc. Type of system: []Absorption trenches OAbsorption bed a Gravelless chambers aDry well aSeepage Pit DOther (type) SETBACK FROM WELL # of feet = 115.2 SETBACK FROM POND, STREAM OR IRRIGATION DITCH # of feet = 65.2 SETBACK FROM DRY GULCH # of feet = 40.2 FPCrI : 0 FRx NO. : 0c,629 2004 08=15RM P2 CHURCH & Associates, Inc. ENGINEERS & GEOLOGISTS October 27, 2004 Michael Fuller do Bob Chapman 23400 Two Rivers Road Basalt, Colorado 81621 Subject Subsurface Investigation and OWS Design, Proposed Fuller Barn Tract 11, Aspen River Valley Ranch Subdivision Last Chance Ranch Pitkin County, Colorado Job No. 16085W Mr Fuller, As requested, we have prepared a revised onsite wastewater system (OWS) design for the proposed residence The revisions arc based on an increase in the living area square footage of the caretaker unit above the bam Brom our latest revised design, dated September 15, 2004, under Job No. 16085W. The subsurface investigation was performed on June 24, 2004. SITE CONDITIONS The property is in a rural residential area of Pitkin County, where OWS are required. The proposed drain field area slopes approximately 5% to the southwest The drain field area has a full cover of native grasses and weeds. Water is supplied to the site by an existing well located greater than 100 fleet to the southwest of the proposed drain field area PROPOSED CONSTRUCTION A horse bam with four horse stalls, a powder room to serve up to six employees, and a one -bedroom apartment with a 5ving area of 800 ftz, is proposed at the location presented on Figures J and 2. A structure with a living area greater than 700 ft1 must be sized for a minimum of two bedrooms, The OWS was sized based on 680 gallons per day (GPD) using Pitkin County Environmental Health Department (PCEM) loading of 50 GPD per horse stall, 30 GPD per employee for a toilet and sink in the powder room, and 75 GPD per person per bedroom. The sewage loading with a peaking factor of 1.75 is 1 190 GPD. This loading includes washing machines and garbage grinders if additional fixtures in unfinished areas are possible, it is suggested that the OWS be constructed to handle the additional loading. The installation of a properly engineered OWS to serve future build -out can be cost effective DENVER 4601 Wadsworth Boulevard Wheat nldae, CO 60033 www.goo•church.com 303,163.9317 Fax: 303.463.6321 TO rre6-1.677.246.3123 FROM • FPX N0. 0cj*29 2004 08:15RM P3 Revised OWS Desi6m Job So. 16085W, 10/27/04 Page 2 SUBSURFACE CONDITIONS A subsurface investigation was performed by digging four percolation holes, 29 to 40 inches deep and one test pit at the locations indicated on Figure 1. Subsurface materials in the test pit consisted of I foot of clayey, sandy topsoil, underlain by slightly clayey, silty sand to the maximum depth explored of 8 feet. Ground water was not encountered. Percolation tests indicate percolation rates of 20 to 27 minutes per inch (MPU. The average percolation rate is 24 MPI. Percolation data is included as Table 1. RECOWi4ENDAIIONS The installation must. include a septic tank, an effluent pump, and a graveness chamber -trench drain field at the locations presented on Figure 2 The OWS design is based on an average sewage load of 680 GPD and a percolation rate of 24 MPI. The installation must include one 2000 -gallon, two-compartment, concrete septic tank with a pump in a Biotube® pump vault in the second compartment and live Infittrator"m QuiWO chamber -trenches. Each trench must have one row of 12 chambers for a total of 60 chambers and 588 ftZ of infiltrative area. A now splitter basin, or equivalent, is required to distribute effluent to the field. Pump specifications are included as Figure S. Based on soil conditions and evaluation of risk of contamination of surface water and ground water, it is not necessary to add 8 feet additional distance for each 100 gallons of wastewater per day of design now over 1000 gallons per day as specified in the table to prevent contamination. The 100 -foot separation between the proposed absorption arca and the well is appropriate to prevent contamination. Vehicle movement over the drain field area during construction should be kept at a minimum to minimize compaction of the receiving soils. The bottom of the trenches should be scarified with a pick, shovel, or backhoe bucket teeth prior to the addition of chambers. The surface of the field should be seeded after installation of the fields. A native seed mix should be sown at the drain field to revegetate the surface. These mixes do not require irrigation and develop a growth 10 to 15 inches high. No automatic sprinkler system should be installed over the trenches. OPERATION AND MAINTENANCE The owner must realize an OWS is different from public sewer service. The owner must be aware of and assume responsibility for maintenance of the system. In the absence of a monitoring program, the septic tank should be pumped every two years. Effluent filter and screened vaults, as applicable, are to be cleaned during pumping There are daily considerations such as not putting plastic or other nonbio- degradable materials into the septic system. Garbage disposal use should be minimized. The backwash of a water softener may be harmful to the OWS. A separate drywell should be constructed for the backwash waste, if a softener is installed. Chemically treated water from a swimming pool or spas should not be introduced to the OWS. LIMITATIONS A contractor experienced in OWS installation should be hired for the construction. Our investigation, layout, design and recommendations are based on data submitted. If subsurface conditions different from those described in this report are encountered, we should be notified to evaluate the change on the proposed cI FROM • FR`: 1,10. 029 2004 08:16AM P5 40 jtLR-ised OW$ Dc91gn Tob No.16085W,10l27/04 Page 3 be d to e the impact performance ofethe OWS T6 countyandour 6 m must be coes this design, we ntacted upon ompletiontof he OWS on the P All construction is to be in accordance with the ISDS regulations. Pipe type and size, burial requirements, septic tank construction, and other specifications, which are not depicted in our report, are to onform to the requirements of the ISOS regulations The installer of the system is to have demonstrated knowledge of the PCEHD ISDS regulations and requirements. or if we may be of further service, please call. Of/Sri If there are questions OQP O� 10 Sincerely, �,�i 13172 CHURCH & Associates, Inc.,Z7.0 Review d by ONA4E Eric R. Burns Edward O. Church, P.E. Design Technician EOC/erb z Y copies sent 2 copies via FedEx to Byrnes & Associates, Attn: Jun Byrnes, 90 Clay Lane, Aspen, Colorado 81611 Faxed to Byrnes & Associates, Attn: Jim Byrnes, 970-923-6888 Faxed to PCEHD, Attn Nancy MacKenzie, 970-920-5077 FROMFRX N0, 0 29 2004 08:16AM P6 *26.66 ACRES • SCALE TRACT 11, ASPEN RIVER VALLEY RANCH SUBDIVISION 1" = 100' LAST CHANCE RANCH PrVN COUNTY, COLORADO A bb TIE LOCATION OF EXSTNO AND PAOFOSED IMPROVEMENTS :.MOWN IEREN MID Tlf WELL MD/Op'•:; •., ORAN FIELD LOCATIONS STAKED AT TME .ITE ARE NOT TME PF,SIAT OF A IADPCRTY SUIVlT. IMPROVEMENT LOCATIONS ME WT'ROANWTE. 17 LR THE { OPERTY OIWER'S RESPONSIBILITY TO DEFINE PROFERTY POIFvDARIES AM EW4M ALL UNS"E IMPROVEMENTS ARE LOCATED WITHN THE PLATTED SITE AND DDT OF INMPROPMATE CASEMENTS. ALL SETARATgN DISTANCES ARC TO PE VERIFIED P" TD EXCAVATION. o�jr WSTINO m / \. \ RESIDENCE EXISTING DRIVEWAY TEST PIT PROPOSED MORSE BARN EXISTING WELT- `��' WITN I-REDROOM APARTMENT SITE PLAN AND LOCATION OF JOB NO. 1 B0B6W PERCOLATION HOLES 10,27104 REVISED FIGURE 1 FROM: 0 F111 M* 0 29 2004 08:16AN P-1 1 *26.68 . ACRES C6 SCALE TRACT 11. ASPEN RIVER VALLEY RANCH SUBDNOON 30' LAST CHANCE RANCH PMN COUNTY, COLORADO \ \�\ \ \ %ftNCE ZQ . . ....... . \OW SPLITT 8 SIN EOLIrVALEW) SCTeA TO DRA- FPFJ-D ZODO�,ALITCK AR I M\ENT 'A, A . M Mot: . . . . . . . . . . . N��C RETE So WITH BIOTLOIE(R) Pt AULI INI�Tlli SfCONO C ILTR T C AGFA -C" I OF TMENT. IN FZ 4-r TM) GUICK401) CRAVELLESS C TRENCHES. E MIST HAVE ONE ROW 2 CHAMBER'.. FOR A TOTAL 00 CH PS. v TBACK TO TIC TAW 0 • .00 0 EX. ING WUL\ \'` PROPOSED BARN Wlt ii. `� / /. HORSSTALLS AM i-86ROOM APARTMENT OF ED OW, ONO. 1`&86W VENT PIPES (TYr) PVC Pump LME V SEWER LINE WITH CLEANOUT REVISED FIGURE 2 0 O TYPICAL PLAN VIEW - N.T.S. w SPLITTER BASIN (OR EOJ!VA'1NT) QUICK4(R) ENO CAPS ' TR J. 055FJtVATOH/ WENT PIPES 4' PVC HEADERS 2lNnLTItAT0R(TM)OUlCgK4�R)O Y PVC PJM? LINE A O TYPICAL CROSS-SECTION - N.T.S. TOTAL - FIVE TRENCHES nolra1mn24m• t' SDR 35 PVC FUR BSERVATION/VFNT PIPE GRAVITY PLOR WITH CAP BMA1�'(E ]JOE w •�-=..w 1 E9Awnu {' RX I ==o= 1 .w 4n'E `� MIN. OR,�HA�`= 1.5 Ma NFlLTRAT3R(IM) QUIM4(R) i s.Re amm. EXTENT OF EXCAVATM GRAVnMLES5 CHAMBER. 3' X {' CALCULATIONS AND SPECIFICATIONS DESGK CRITMA INCH SPECIFICATIONS TREAT/.ENT UNIT SPECPICATKINS SAM - A HORSE SCALLS, 1 PO'AOER ROOM FOR 6 OAP:OYEFS, & 1 -BEDROOM KUMBER OF TRENCHES - 5 LENGTH OF EACH TR - 48 FEET. 17 CHAMBER TOTAL MIMMUM CAPAgTY = 1.75 X q X (JO HOURS/24 HX%S) APARTMENT, 800 SF LOADING - q - (t • 60 GPD) + IS G 30 GPD) + (2 G 2 x -HCH 75 CPD) - 680 GPD WIDTH OF EACH TRENCH = 3 FM. 1 CHAMBER - 1486 GALLONS ✓ PERCOLATION TEST - L - 24 MPI / TOTAL NUMBER OFF CKAM376 - 60 CHAMBERS I/ RECOMMENDATION: ONE I003 -GALLON, TWO-COMPARMEAT, AREA - 0.75 x q . Vq t t) / 5 - 1165 SF •/ GONCRETE SEPTIC TANK MM A 80TUE(R) PUMP VAULT M 502 REDUCTION FOR CHAMBER-TRENCRM - 563 SF THE SECOND COAPARMENT DRAIN FIELD DETAILS 10/27/04 JOB NO.. lO0 W REVS RGUEE 3- M l 2000 -Gallon, Two -Compartment, Concrete Septic Tank with Effluent Pumping System 0� AULT INLET PORTS CLEAR ZONE OPENING IN LOW INDUCER 24' Dl A. PVC RISER WITH FIBERGLASS GASKETED LID ACCEPTABLE ALTERNATIVE GROMMET(S) (BOND To CARTRIDGE WITH STAINLESS STEEL BOLTS k!FILTER TANK ADAPTER WITH AND 2' INSULATION - RECOMMENDED ADHESIVE)orewoSystem ?4' DIA. PVC RISER WITH 1 �,p„�,d PVC SPLICE BOX M (BONDTO SLOPE GROUND W/CORD GRIPS TAN 4 A 871 All AVDFA AWAY FROM RISERS (TVP.) CONDUIT SEAL RECOMMENDED ADHESIVE) SUREIOIA 01®011 _III—I =1 I I—III— I—Ti—• . COi1�UVT �0 E .. DISCHARGE ASSEMBLY 971A-9014 CONTROL PANEL FLEXIBLE HOSE EFFLUENT DISCHARGE (541) 49-449 INLET 1/4' WEEP HOLE (50) R BAFFLE 45 -29114 TANK ADAPTER (CAST OR BOLTED) o LIQUID LEVEL LEVEL CONTROL FLOAT ASSEMBLY __ft��nyy If 4,439,323 t 5.402,615 g'amign POW Amd" 1997, Orwm Sylr9rs. Im DISCLOSURE: THE PRESIDENT OF CHURCH B ASSOCIATES, INC. IS A NON -PARTICIPATING OWNER OF SCG ENTERPRISES, INC. WHICH IS A LOCAL DISTRIBUTOR CF ORENCO SYSTEMS, INC. PRODUCTS. THIS DRAWING WAS PROVIDED BY OSI AND HAS BEEN MODIFIED BY CHURCH FOR THIS PROJECT. CHURCH a Assodatm hto. 10/27/04 4501 wro Bow d TYPICAL SEPTIC TANK WITH PUMP JOB NO. 16085W Wheat Ridge, Colorado I REVISED FIGURE 4 I AULT INLET PORTS CLEAR ZONE OPENING IN LOW INDUCER THE BAFFLE IS AN SI EFFLUENT PUMP ACCEPTABLE ALTERNATIVE CARTRIDGE TO PVC TEES k!FILTER RAIN PORT IOTUBEOPLPIP VAULT __ft��nyy If 4,439,323 t 5.402,615 g'amign POW Amd" 1997, Orwm Sylr9rs. Im DISCLOSURE: THE PRESIDENT OF CHURCH B ASSOCIATES, INC. IS A NON -PARTICIPATING OWNER OF SCG ENTERPRISES, INC. WHICH IS A LOCAL DISTRIBUTOR CF ORENCO SYSTEMS, INC. PRODUCTS. THIS DRAWING WAS PROVIDED BY OSI AND HAS BEEN MODIFIED BY CHURCH FOR THIS PROJECT. CHURCH a Assodatm hto. 10/27/04 4501 wro Bow d TYPICAL SEPTIC TANK WITH PUMP JOB NO. 16085W Wheat Ridge, Colorado I REVISED FIGURE 4 I Pump Selection for a Non -Pressurized System Input Parameters 0.0 feel Design Flaw Rate 30 Wm DistnbNchg Valve Model None Lift to Discharge 20.0 feel Transport Length 75.0 feel Transport Line Size 2.00 inches Transport Pipe Class/Scnedule 40 Discharge Assemtify Sue 1.25 inches Flow Meter None incres 'Add-on' Friction Losses U 1en Head Loss Through Distributing Valve 0.0 feel Head loss in Transport Pipe 11 feet Head Loss Thmugh Discharge 45 feet Head Loss Through Flow Meer 0.0 feet 'Add-crh' Frictron Losses 0.0 leer Total Flow Rate 30.0 gpm TDH 25.7 feet Job No. 16065W Revised Figure 5,10x27/04 B 12— Net Discharge, gpm Ca Irene Systems* IncaCcraled Al f AMM AY AVNJF SU-IiEHI1fl, OFECON 97579 • TOLL FRff 7 X1396 -9&t7 ci TELEPHONE .. CA11454W FAGSMU C,n1uB IDBa NYIW.01Yr1C0.CVT J m SECTION VIEW SIDE VIEW INFILTRATOR(R) QUICK4(TM) CUT SHEET • 9 N ID N m m CD m mD 3 FROP1 �y Fi : N0. 0 29 2004 08:18RM P12 TABLE 1 - PERCOLATION TEST RESULTS Tract 11, Aspen River Valley Ranch Subd. DATE OF TEST: 6/24/04 Pitkin County, Colorado TP -1: 2-1 !Topsoil, sand, clayey, moist, root zone 1 -8 Sand, silt ,all htl cls a ,moist, red, with occasional cobbles NO GROUNDWATER WAS ENCOUNTERED WITHIN EXCAVATION INTERVAL AVG. DEPTH TIME DEPTH DEPTH CHANGE, PERC, HOLE HOLE NUMBER OF HOLE, INTERVAL, START, END, (INCHES) RATE PERC. (INCHES) (MINUTES) (INCHES) (INCHES) (MPI) RATE, IMPII 2 31 10 4.50 5.13 0.63 16 10 4.00 4.50 0.50 20 10 3.38 4.00 0.63 16 10 4.00 4.38 0.38 27 10 4.38 4.75 0.38 27 10 4.75 5.13 0.38 27 27 JOB NO. 16085W FPDrl : • FAX N0. : 01029 2004 08:18AM P13 TABLE 1 - PERCOLATION TEST RESULTS Tract 11, Aspen River Valley Ranch Subd. Pltkln County, Colorado TP•1: tan} daerrinllnn DATE OF TEST: 8124/04 0 - 1 To soil sand, clayey, moist root zone 1 -8 i1band, silty,611ghtly clayey, moist rod, with occasional Cobbles NO GROUNDWATER WAS ENCOUNTERED WITHIN EXCAVATION HOLE DEPTH TIME DEPTH DEPTH INTERVAL AVG. HOLE HOLE OF HOLE, INTERVAL, NUMBER START, END, CHANGE, PERC, (INCHES) (MINUTES) (INCHES) (INCHES) (INCHES) RATE RATE, (MPI) JOB NO. 16085W I�iliil!• JOB NO. 16085W 0 17 0 -- ] t o 9g Z W z UZ Z Q 2m LUU) 1/�/)i1 < O 2 PERMIT SET ai MMlpb. ub, wmp•�bb N Nb Mwb >�.P ba.V.Uk w.MMM' tlbMSRpMMI.Yp W p..bblb mrMvs.rC M.Mw 'Mlb bN.bw YW W pw.MomwwMC dmwW.NbbM �b.wMybl M✓ .M4np MMf4FCOnvbmrw.yl-.bM p M.uY PROJECT NO: 21009 DRAWN BY: EE CHECKED BY: ISSUE DATE: FEBRUARY 9.29a FILE NAME: -LOOR PLAN A.101 • • o o_ Ow q m ----------------- 6 p Aay :: r ao � A.102 904MM April 19, 2004 Jim Byrnes 300 East River Ranch Rd. Snowmass, CO 81654 ATTN: Jim On April 16, 2004, a well test was conducted on a well on the Byme's (300 E. River Ranch Rd.) Property. The following information was obtained; Well Depth------------------------- Approx 60' Casing Size--------------- 7 x 5" Standing water level------------------- 23.23' Total test time------------------- I Hour Drawdown to ----------------------- 23.65' Production is ------------------ 20 GPM This test was conducted with Existing 114 Hp pump. The well recovered back to 23.23' in ! , Minutes. If you have any questions please call me, Raun Samuelson at 970-945-6309. Sincerely;' Raun E Samuelson Samuelson Pump Co. P.O. Box 297 • Glenwood Springs, CO 81602 • (970) 945-6309 • Fax (970) 947-9448 Water Systems • Sales, Service & Installation Form No. OFFICE OF TH ATE ENGINEER • GWS -25 COLORADO DIV ION OF WATER RESOURCES 818 Centennial Bldg., 1313 Sherman St., Denver, Colorado 80203 !3031 ARA 45A1 APPLICANT MIN LIC WELL PERMIT NUMBER 235481 _ DIV. 5 WD 38 DES. BASIN MD Lot: 11 Block: Filing: Subdiv: ASPEN RIVER VALLEY RANCH ROBERT CHAPMAN % PATRICK MILLER & KROPF PC 730 E DURANT STE 200 ASPEN, CO 81611- (970)920-1028 APPROVED WELL LOCATION PITKIN COUNTY NW 1/4 SW 1/4 Section 25 Township 8 S Range 86 W Sixth P.M DISTANCES FROM SECTION LINES 2695 Ft. from North Section Line 880 Ft. from West Section Line UTM COORDINATES ISSUANCE OF THIS PERMIT DOES NOT CONFER A WATER RIGHT CONDITIONS OF APPROVAL 1) This well shall be used in such a way as to cause no material injury to existing water rights. The issuance of this permit does not assure the applicant that no injury will occur to another vested water right or preclude another owner of a vested water right from seeking relief in a civil court action. 2) The construction of this well shall be in compliance with the Water Well Construction Rules 2 CCR 402-2, unless approval of a variance has been granted by the State Board of Examiners of Water Well Construction and Pump Installation Contractors in accordance with Rule 18. 3) Approved pursuant to CRS 37-92-602(3)(b)(II)(A) as the only well on a tract of land of 38.30 acres described as lot 11, Aspen River Valley Ranch division of land, Pitkin County. 4) The use of ground water from this well is limited to fire protection, ordinary household purposes inside not more than three (3) single family dwellings, the watering of poultry, domestic animals and livestock on a farm or ranch and the irrigation of not more than one (1) acre of home gardens and lawns. 5) The maximum pumping rate of this well shall not exceed 15 GPM. 6) The return flow from the use of this well must be through an individual waste water disposal system of the non -evaporative type where the water is returned to the same stream system in which the well is located. 7) This well shall be constructed not more than 200 feet from the location specified on this permit. Qj $1Cy'I"7 APPROVED JSG State Engineer 14