HomeMy WebLinkAboutpitkin.eh.246721201004 (1994)NOTE IT IS THE RECOMMENDATION OF THE ENGINEER THAT A )OSING SYSTEM BE USED FOR THE SEPTIC SYSTEM. HOWEVER, IF IS NOT REQUIRED BY THE STATE OF COLORADO HEALTH DEPAR°TRENT OR THE PITKIN ENVIRONMENTAL HEALTH DEPARTMENT. IT Hi,S BEEN SHOWN THAT A DOSING SYSTEM HAS A LONGER LIFE SPAN THAN CONVENTIONAL GRAVITY OPERATED TRICKLE SYSTEMS. GRAVITY SYSTEMS HAVE BEEN SHOWN TO CONCENTRATE EFFLUENT AT ONE SPECIFIC AREA OF THE LEACH FIELD, THEREFORE CAUSING A LOSS IN THE ABSORPTION RATE AT THE SPECIFIC AREA. THIS TYPE OF SOIL FAILU'tE IS PERMANENT. THE EFFLUENT IS THEN CONCENTRATED ONTO THE SURROUNDING AREA EVENTUALLY CAUSING TOTAL FAILU tE OF THE SEPTIC SYSTEM. USING A DOSING SYSTEM, A MORE UNIFORM DISTRIBUTION OF THE EFFLUENT IS ASSURED. THE DOSING SYSTEM INUNDATES THE LEACHING AREA AND THEN ALLOWS THE SOIL TO REST AFTER THE LIQUID LEVEL OF THE DOSING TANK HAS BEEN SIPHON TO A LEVEL BELOW THE SIPHON INTAKE. IF A GRAVITY SYSTEM IS USED: DRILL 2" PVC FEEDER PIPE O 5 O'CLOCK AND O 7 O'CLOCK EVERY 1 FOOT ALONG PIPE INSIDE CHAMBERS. DRILL ONE 3/8' HOLE 0 6 O'CLOCK IN THE PIPE AT THE END OF EACH LEACH CHAMBER TO ALLOW PIPES TO DRAIN I;OMPLETELY. CALCULATIONS FOR LEACH FIELD :;ISE CURRENT PROPOSED RESIDENCE IS A THREE BEDROOM HOUSE ASSUME 2 PEOPLE PER BEDROOM ANU ;'4 :"?AGE ]AJLY A:WAGE FLOW OF 75 GALLONS PER PERSON PER DAY ACCORDING T(I THE COLORADO STATE DEPARTMENT OF HEALTH: THEREFORE: (3 BEDROOMS) X (2 PEOPLE/BEDROOM) — 6 PEOPLE (6 PEOPLE) X ( 75 GPD/PERSON) - 450 GALLONS PER DA,' (AVERAGE DAILY FLOW) MAXIMUM DAILY FLOW — 150% OF AVERAGE DAILY FLOW, THEREFORE: MAXIMUM DAILY FLOW - (1.50) X (450 GPD) - 675 GAL)NS PER DAY --------------------------------------"-------------- THREE PERCOLATION IESTS WERE CONDUCTED BY JEROME CAMBA AND ASSOC., INC THE RESULTS ARE A" FOLLOWS: TEST PIT NUMBER P aF U A„� TION RATI(MIN NCH) TEST PIT 01 20 MINUTES.iNCH TEST PIT 02 8 MINUTES,1NCH TEST PIT r3 10 MINUTF.SjINCH MINIMUM BOTTOM ARLA FOR ABSORPTION BEDS SHALL BE CALCULATED AS PER PITKW COUNTY ENVIRONMENTAL HEALTH DEPARTMENT USING. THE FOLLOWING FORMULA. A - (1.85)X(Oi — .055(0) WHERE 0 — AVERAGE DAILY SEWAGE FLOW — 450 GALLONS PE& DAY L - LOADING RATE (AS DETERMINED BY PITION COUNTY TABLE 5-6.5(o)) t - AVERAGE PERCOLATION RATE - 13 MINUTES PER TECH THEREFORE A - (1 941X( AO) _ ,055(450) - 1,194 S.F. 0.72 CONSERVATIVELY, 1,200 SQUARE FEET WILL BE USED AS R - ABSORPTION AREA FOR A NORMAL LEACH FIELD. ACCORDING TO THE STATE DEPARTMENT OF HEALTH, WHEN THE INFILTRATOR LEACHING CHAMBER IS INSTALLED IN A BED CONFIGURATION A REDUCTION OF 4Ox W THE SIZE OF THE ABSORPTION AREA IS ALLOWED. BECAUSE OF THE POSSIBILITY OF HIGH GROUND WATER ASSOCIATED WITH THE SOIL TYPE FOUND A' THIS LOCATION, IT IS OUR OPINION THAT A REDUCTIO/ OF ONLY 35x BE APPUED IN THIS ARE, THEREFORE: (0.65) X (1200 SQ.FT.) - 780 SQUARE FEET OF INFILTRATLRS THE AREA OF ONE INFILTRATOR UNIT - 18.75 SOFT. THEREFORE: THE NUMBER OF INFIRTRATOR UNITS REQUIRED - (760 SQJM,AIB.75 SQ,FT.) - 42 UNITS THE INFILTRATOR BW WILLBE E L � Y TME�?�NGG CTOR NTO RENES. THE INFILTRATOR BED WILL CONSIST OF B WFlI G. THE 80 WILL HAVE A MINIMUM OF 24' COVER OVER THE -iE ENTIRE INFILTRATOR BED. MINIMUM SEPTIC TANK SIZE FOR A THREE BEDROOM RESIDEICE AS REQUIRED BY PITKIN COUNTY IS 1000 GALLONS. MINIMUM HORIZONTAL DISTANCES BETWEEN SEPTIC SYSTEM :OMPONENTS: ABSORPTION 80 TO ANY DITCHES OR WATER COURSES: 50 Ft. ABSORPTION BED TO POTABLE WATER SUPPLY OR SUPPLYUNE: 25 FL ABSORPTION BED TO PROPERTY IJNES 10 Ft. ABSORPTION BED TO SEPTIC TANK: 10 Ft ABSORPTION BED TO RESIDENCE. 20 Ft ABSORPTION BED TO SPRING OR WELL 100 Ft ALL COMPONENTS OF THE SEPTIC SYSTEM SHALL BE INSTAI.ED ACCORDING TO PITKIN COUNTY ENVIRONMENTAL HEALTH CODES AND ACCORDING TO "NURCTURERS SPECIFICATIONS. REV I DATE 0 / 1000 GAL. SEPTIC TANK DOSING CHAMBER REVISION 4"x4'x4' TEE 2"404' TEE (BOTH SIDES) 20 0 20 40 60 GRAPHIC SCALE IN FEET 1 INCH - 20 FEET / / / / 7-7 0 0 40x2" REDUCER COUPLING (BOTH SIDES) 2" 90% BEND (TYP) I 2"x2'x2' TEE (BOTH SIDES) l DOSING SYSTEM RECOMMENDED SYSTEM MADE ICHKD I APi'D BY BY B'v' �I 4" RISER PIPE / r / r / r r / _ / r r SITE PLAN �s-�j(..l.tt�i ��AvlllAJCr NOLLI*D H I LLB ;oAn O KADOTA 5' MIN. \ \C o 01 45% BEND 1000 GAL SEPTIC TANK \� 4" DISTRIBUTION UNE ,,ADS 1369DB DISTRIB!ITION BOX OR APPROVED EQUAL ' I4" PVC -DISTRIBUTION PIPE -�✓ I LEACH BED TO BE 6 1NFI_TRATOR UNITS WIDE BY 7 UNITS LONG (TOTAL OF 4� INFILTRATOR UNITS) 01 20'/ MIN 4"IRISER PIPE 10' MIN. GRAVITY SYSTEM r / MINIMUM PERMITTED SYSTEM r / / SEPTIC DISPOSAL SYSTEM SITE PLAN & NOTES SCALE: DATE: SHEET 1" = 20' OCTOBER 26, 1993 I 1 OF 2 DRAWN BY: CHKD BY: APPD BY: PLAN N0. CWS MJG 1 MUG I 93204\SEPTIC ISD O TA RESIDENG'E LOT 39 HOLLAND HILLS PITKIN COUNTY, COLORADO I WHILLOCK-BUCKINCHAM PARTNERSHIP I COMUNG BIC EERS & LAND SIIHVEI'ORS POST OFFICE BOX 1458 113 NINTH STREET, SUITE 214 GLENWOOD 945-2550 SHEET N0. PROJECT: 93204 4" PVC SEWER PIPE E` MINIMUM SLOPE = 4% PVC FEEDER PIPE. DRILL 3/8" HOLES ® 3 O'CLOCK AND 9 0"CLOCK EVERY I' ALONG PIPE INSIDE CHAMBERS. DRILL ONE 3/8" HOLE O 6 O'CLOCK AT THE END OF EACH LEACH CHAMBER TO ALLOW PIPES TO DRAIN COMPLETELY. INVERTS TO BE AT THE SAME ELEV. IN EACH DISTRIBUTION BOX. 4z2" F 1 -A —1 � 1� I E I T)--1 I 1� I BACKFILL WITH EXCAVATED wrcRIAL (SEE INFILTRATOR INSTALLATION IN'.:TRUCTIONS) CIYnRL LCMVnu4U JURI-MVC IV ['_ LGVCL V"IIllll\ i U.UJ BCCI. `I I U E c_, R c_i' f. (_. I L_ N v f W SCALE. ,• - _ _ ---.-- --- ---- "" "'SER W/ PLASTIC VALVE BOX COVER " OF PVC TO BE PERFORATED (TYP) INFILTRATOR LEACHING CHAMBERS OR EQUAL. LEACH BED SHALL BE 6 UNITS WIDE BY 7 UNITS WIDE. NATURAL GROUND r 4"x2"x2" TF -1, _. 2"x2"x2" 1 INFILTRATOR LEACHING CHAMBERS OR EQUAL. LEACH BED SHALL BE 6 UNITS WIDE BY 7 UNITS LONG. F RUN 1 S� ALL I = _ 4" PVC RISER W/ PLASTIC VALVE BOX COVER. TO BE PLACED ® APPROX CENTER OF TRENCH BOTTOM 8" OF PVC TO BE PERFORATED (TYP.) Lai;•m I Lei I rem • m to.•• THE SEPTIC TANK SHOULD BE PUMPED ANNUALLY TO PREVENT THE BUILDUP OF FLOATING SOLIDS AND SLUDGE. FAILURE TO DO SO WILL RESULT IN SOLIDS ENTERING THE LEACH FIELD CAUSING THE LEACH FIELD TO FAIL.