1 /c
Pitkin County Environmental Health Department
Permit for an Individual Sewage Disposal System
130 S. Galena St., Aspen, Colorado 81611
Phone 970-920-5070 / FAX 970-920-5074
Permit # 00074 Parcel ID # 2467-324-00-009
Type of permit New( ) Repair( ) Addition to House() REMODEL OF OLD HOUSE
Name of Owner Biddle LLC / Land and Cattle Co LLC
Street Address 5459 E. Sopris Ck Rd
Property legal description
Size of lot 300 acres Total square footage of the house 2,658
Water source Private Well
# of bedrooms in house
Caretaker unit
# of offices, lofts & similar sized rooms in house
Total square footage of the caretaker unit
# of bedrooms in caretaker unit # of offices, lofts & similar sized rooms in caretaker unit
l9es# ^ttit1R'rooFrls^�Ij - THRE'�edroom's : ^ >' ... ,NOW
Permit information
Designed by Timberline Engineering
Mailing Address PO Box 631, Carbondale, CO 81623
Perc rate 34 mpi Profile hole depth 8 ft Depth to groundwater or bedrock
5-1/2 ft
Septic tank capacity 1500 Absorption area *see engineer design
Comments
Septic permit approved per compliance with the engineer design and specifications dated 8/18/00. Any changes
must be approved by this department and the design engineer prior to them being made. Minimum horizontal
distances between components of the system and physical features shall conform to the Pitkin County ISDS
regulations.
Design is for a 1500 gal. Two compartment concrete septic tank, a sand mound with a sand bed area of 54 X 32.33
= 1746 sq ft, and an infiltrator bed of 8 units X 10 units = 80 units total. The sand must conform to Section 12-5
of the Pitkin County ISDS regulations and an invoice to document the sand material must be submitted.
This department does not endorse any brand of products. The engineer must do a final inspection of the installation
and submit an as -built letter to this department. This department must also be called for an inspection with a
minimum of 48 hours advanced notice. An acceptable water quality test is required before this permit can be finaled.
Permit approved by: Date: a 5-10 e)
Plans and specifications of the pr osed individual sewage disposal system have been reviewed and are considered
satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin
County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was
issued unless system construction has commenced or an extension has been approved in writing by the Department.
As -built drawings must be included with this
rinstaller: ( nn k,�y�r�•_-✓
approval will be issued.
D�te�: lc
ASPEAKIN ENVIRONMENTAL HEALTH ARTMENT
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM
130 S. Galena St., Aspen Colorado 81611
Phone 970-920-5070/Fax 970-920-5074
Name of OWNER
_
Q'/& q
Owner's Mailing Address
Business Phone: Q
30 A
- p
BG oj rn el&n I (
Home Phone: 3
Primary Contact Person (all communication regarding this permit will go through this person)
Name
Company
1} T ✓\
CilDnl
Contact Mailing Address
Business Phone :IRZ$
3 O le -L'
(J& CelPhone:TOb
S t^b 01&11
2(,0 Fax: ZS-,a)e)q
at 920-5160 or at www.aspen.com/assessor/)
Street address of property
Legal Description: Lot
Size of lot: 392 acres.
a-�- /-,-7_�24_0 0.00
,Block Filing Subdivision
Type of proposed structure: �-A7-6.44;6Size of bldg. envelope:
Total square feet of house # of bedrooms in house
# of offices, lofts & similar sized rooms in house O
Caretaker Unit: Attached ( ) Detached (
# of bedrooms in caretaker unit # of
Total area(sq. ft.) of caretaker unit
lofts and similar size rooms of caretaker unit
Permit is for: New Home ( ) Repair due to failure ( X ) emo /Addition ( ) Emergency use ( )
Water: Private well ( )< ) Spring ( ) Stream ( ) Community/Public Water System ( )
If community system: Name of system
The fee for a ISDS application is $330 for a permit that takes 6 hours or less for the department to approve. If approval takes
longer than 6 hours, a rate of $55 per hour will be charged. The maximum fee is $1000. The basic fee of $330 is due at the time
of application. The remainder, if any, will be due in two stages: first, at the time of issuance of the ISDS permit: second, before
final approval of the ISDS permit.
Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information is true and
accurate and that I have provided true and accurate information on locations of all existing and proposed wells, contour
intervals, buildings, property lines, ditches, slopes, watedines, springs, suction or irrigation lines, drinking water cisterns, drain
tiles, irrigation ditches, lakes, water courses, streams, floodplains, dry gulches, and existing septic systems. I hereby certify
that any such features not shown on attached site map are not present. Issuance of the permit does not imply the approval of
any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all
approvals and permits have been obtained.
The Aspen/Pitkin Environmental Health Department, Pitkin County and employees of these agencies will be held harmless
should the individual sewage disposal system fail or malfunction. The permit to construct is issued on information submitted by
the applicant or his/her representatives. The owner assumes full responsibility in case of failure of the system.
Signature of applicant �17�/L Date r!9 .,!10
Received by A Receipt # r? -�2 r 7_) Date 9 -/
G:\eh\ i sds\isdsa p p. do
3
ASPEN/PITKIN ENVIRONMENTAL HEALTH DEPARTMENT
SEPTIC SYSTEM APPLICATION CHECKLIST
NOTE: SEPTIC PERMIT APPLICATIONS CANNOT BE ACCEPTED UNTIL ALL OF THE
INFORMATION BELOW IS INCLUDED.
The soils test and system design must be done by a Registered Professional Engineer. You
should plan to meet with the RPE at your site to discuss where the soils tests should be done
to meet all of the County regulations and where you want to put your house. The RPE will be
your contact for issues you want to discuss about your system's size and location. The RPE
should check each box to indicate the following have been submitted before the application
can be accepted.
® CoMRleted application form
Engineer design stamped by a RPE registered in the State of Colorado.
Site map showing locations of, or stating that the following do not exist: all existing
and proposed wells within setback distances (including on surrounding properties),
contour intervals, all proposed and existing buildings, property lines, ditches, slopes
of greater than 15%, water lines, sprinkler systems, springs, suction (irrigation) lines,
drinking water cisterns, drain tiles, irrigation ditches, lakes, ponds, water courses,
streams, floodplains, floodways, dry gulches, or existing septic systems. This must
include all such features on neighboring properties within setbacks.
Complete building floor plans. Floor plans should be 11x17.
Proof of adequate water supply: for private wells, recent well driller's pump test
showing gpm actually produced, well permit showing legal supply, and test showing
good quality; for community systems, proof there is adequate water for all houses
served by the system; for other systems, proof of adequat$c i ' and number of
gallons/ minute. Well must be drilled before septic permit can be issued.
Env. Health has been called to look at profile hole
�Ulf Percolation tests (make sure to do lesser of 3 holes or one/1200 sq. ft. of field
17 Permit fee
NA
Copy of county approval (1041 approval, subdivision approval, etc.)
��A
Check if your septic em is within th uildin envelo nd no part of the
system is more tha 30" Bove grade. If both of these conditions are not met, you
must obtain writrT7A/F11-TR,f
proval from Community Development before submitting
this application.ND FV 7-AER
g:\eh\isds\isdschck /
joRS _ ?'48vVc'O&DE
SO14 COww
O)As
pen / Pitkin Environmental Health Department
Contact Log Sheet
E
•
11
' : Address:
" 4_
1_J •_
Person Spoke'n To
Comments I Action to be Taken
-�/
O
Y//L'///l4MII
E
•
11
4?V
/ 1 4
!,
,.
.. , -.
a
I
r
r: rl
1
t
1•
r
ok
s�
� Mr.
I
STRU ]CIIJ UUCRII L ENGRRUW3NG # CONTRACTII G # CERTIFIED ENERGY DESIGN PROFESSIONAL
October 15, 2000
Pitkin County Environmental Health
Attn: Nancy MacKenzie
130 South Galena
Aspen, Colorado 81611
Re: ISDS Installation
Light Ranch
5459 East Sopris Creek Road
Pitkin County
Dear Nancy:
The installation of the ISDS for the above residence has been completed and has been installed
in accordance with applicable county specifications and the approved plan. Enclosed is the as -
built drawing for the system.
If you have any questions, please call me at 963-9869.
Sincerely,.
David A. Powell, PE � �1
t
Reg. No. 25851
cc: John McBride
303 E AABC
Aspen, CO 81611
]P.O. BOX 63 R CARBO2DALE, CO. 81623 ]PHONE 970 963 9869 / FAX 970 963 9003
August 15, 2000
,rth•Paulak Geotechnical. Inc.
'ounn Road 154
Glenuro,d Springs Colorado S16ol
P!vme: 9711-945-79.48
�':,.: •1711.945-x454
:a:cc•�•• I:»gcotrch.cum
Kate McBride
303 East Aspen Airport Business Center
Aspen, Colorado 81611 Job No. 100 641
Subject: Percolation Testing, Proposed Septic Disposal System, 5459 East Sopris
Creek, Pitkin County, Colorado.
Dear Ms. McBride:
As requested. a representative of Hepworth-Pawlak Geotechnical, Inc. conducted
percolation testing at the subject site to evaluate the feasibility of an infiltration septic
disposal system. The results of our work are presented in this report. The work was
done in accordance with our agreement for professional services to you, dated August
2, 2000.
A profile pit and three shallow backhoe pits had been excavated at the locations shown
on Fig. 1. Percolation test holes were hand dug in the bottom of the backhoe pits. The
test holes were soaked one day prior to testing. The soils exposed in the percolation
holes are similar to those exposed in the profile pit and consist of about 1 foot of topsoil
and 3 feet of medium dense clayey sand with gravel overlying relatively dense slightly
silty sandy gravel with occasional cobbles to the profile pit depth of 6 feet.
Groundwater was observed in the profile pit at a depth of 51/2 -feet and the upper soils
were slightly moist to moist.
Percolation tests were performed on August 4, 2000 by a representative of Hepworth-
Pawlak Geotechnical, Inc. The percolation test results are presented on Table 1. The
percolation test results indicate an infiltration rate between about 14 and 60 minutes per
inch. Based on the subsurface conditions, particularly the shallow groundwater, we
recommend a civil engineer be engaged to design the infiltration septic disposal system.
If there are any questions or if we may be of further assistance, please let us know.
Sincerely,
HEPWORTH WLAK G MCA
�N AO j�
Jordy Z. Adamson, r., ,t
Rev. bys DEHJZA
...L,
attachments c �c/0NAL E �'
cc: High Country Engineering - Attn: Deric Walter
is
Roaring Fork Sand & Gravel
Carbondale Pit
1415E Highway 82
Carbondale, CO 81623
DATE: 09/28/00 TICKET: 345335
CUSTOMER: HART J Jerry Hartman Constriction
HAULER: Sochovka Trucking
TRUCE',: S0qH 9
DRIVER: my OFF
ORDER: 5459 East Sopris Creek
PRODUCT: ISDS Individual Sewage Disposl
GROSS: 53800 LBS
TARE : 25080 LBS QUANTITY: 14.3E TON
NET 28720 LRS
* Manual Weight
TIME: 15:14
Loads Today: 7
Gty. Today: 99.84
WSW*4
RATE
FREIGHT:
TAX
TOTAL
AMOUNT
WeighMaster• UWA11&1 l
I
INVOICE EDITOSTING THROUGH 09/28/00 - GALS DETAIL
09/29/00 09:12 am Roaring Fork Sand & Gravel Page 1
RESTRICT TO CREDIT TICKETS
BILLING GROUPS: GROUP A GROUP B GROUP C GROUP D GROUP E
TICKET DATES: 09/01/00 TO 09/28/00
LOCATION: 1 CUSTOMER: HART J ORDER: PRODUCT:
HART J Jerry Hartman Construction
TICKET
DATE
ORDER LOCATION P.O.
DELIVER
PRODUCT
QTY
MAIL
FREIGHT
OTHER
FEE
TAX
TOTAL
345127 M
09/27/00
5459
SOP 1
5459
East
Delivery
3.50
0.00
192.50
0.00
0.00
0.00
192.50
345143 M
09/21/00
5459
SOP 1
5459
East
Delivery
9.00
0.00
495.00
0.00
0.00
0.00
495.00
345363 M
_________________
09/28/00
5459
SOP 1
5459
East
Delivery
9.50
0.00
522.50
0.00
0.00
0.00
522.50
SUBTOTAL
________
5459
________ _______
SOP 1
__________
________ _________
0.00
__________
0.00
__________
1,210.00
__________
0.00
______
0.00
______
0.00
___________
1,210.00
344995
09/27/00
5459
SOP 1
5459
East
3/4" Scr
14.74
71.49
0.00
0.00
0.00
2.86
74.35
_________________
SUBTOTAL
________
5459
_______________
SOP 1
__________
_________________
3/4• Scr
14.74
__________
71.49
__________
0.00
__________
0.00
______
0.00
______
2.86
___________
74.35
344998
09/27/00
5459
SOP 1
5459
East
Individu
14.43
324.68
0.00
0.00
0.00
12.99
337.67
345018
09/27/00
5459
SOP 1
5459
East
Individu
14.30
321.75
0.00
0.00
0.00
12.87
334.62
345024
09/27/00
5459
SOP 1
5459
East
Individu
14.91
335.48
0.00
0.00
0.00
13.42
348.90
345043
09/27/00
5459
SOP 1
5459
East
Individu
15.52
349.20
0.00
0.00
0.00
13.97
363.17
345047
09/27/00
5459
SOP 1
5459
East
Individu
16.11
362.48
0.00
0.00
0.00
14.50
376.98
345062
09/27/00
5459
SOP 1
5459
East
Individu
14.73
331.43
0.00
0.00
0.00
13.26
344.69
345078
09/27/00
5459
SOP 1
5459
East
Individu
14.86
334.35
0.00
0.00
0.00
13.37
347.72
345094
09/27/00
5459
SOP 1
5459
East
Individu
13.19
296.78
0.00
0.00
0.00
11.87
308.65
345104
09/27/00
5459
SOP 1
5459
East
Individu
14.25
320.63
0.00
0.00
0.00
12.63
333.46
345125
09/27/00
5459
SOP 1
5459
East
Individu
14.21
319.73
0.00
0.00
0.00
12.79
332.52
345165
09/28/00
5459
SOP 1
5459
East
Individu
14.19
319.28
0.00
0.00
0.00
12.77
332.05
345205
09/28/00
5459
SOP 1
5459
East
Individu
14.05
316.13
0.00
0.00
0.00
12.65
328.78
345214
09/28/00
5459
SOP 1
5459
East
Individu
12.94
291.15
0.00
0.00
0.00
11.65
302.80
345230
09/28/00
5459
SOP 1
5459
East
Individu
13.95
313.88
0.00
0.00
0.00
12.56
326.44
345251
09/28/00
5459
SOP 1
5459
East
Individu
14.00
315.00
0.00
0.00
0.00
12.60
327.60
345273
09/28/00
5459
SOP 1
5459
East
Individu
13.65
307.13
0.00
0.00
0.00
12.29
319.42
345290
09/28/00
5459
SOP 1
5459
East
Individu
13.55
304.88
0.00
0.00
0.00
12.20
317.00
345314
09/28/00
5459
SOP 1
5459
East
Individu
13.78
310.05
0.00
0.00
0.00
12146--
322.45
345320
09/28/00
5459
SOP 1
5459
East
Individu
16.55
372.38
0.00
0.00
0.00
14.90
387.28
345335
09/28/00
5459
SOP 1
5459
East
Individu
14.36
323.10
0.00
0.00
0.00
12.92
336.02
345347
09/28/00
5459
SOP 1
5459
East
Individu
13.70
308.25
0.00
0.00
0.00
12.33
320.58
345364
09/28/00
5459
SOP 1
5459
East
Individu
13.90
312.75
0.00
0.00
0.00
12.51
325.26
_________________
SUBTOTAL
________
5459
________ _______
SOP 1
__________
________ _________
Individu
315.13
__________
7,090.49
__________
0.00
__________
0.00
______
0.00
______
283.65
___________
7,374.14
_______________________________________________________________
INVOICE TOTALS -
-------------------------------------------------------------------------------------------------------------------"'-__________---
26
TICKETS
_________
329.87
__________
7,161.98
__________
1,210.00
__________
0.00
______
0.00
______
286.51
___________
8,656.49
t' #06 1 Tor! %TriL
NORT TO SCALE
EXISTING
GUEST
HOUSE
P 2 A
I
"-.z� , ,
Vi �tv
cJ
j-3
py L
(ZYl1;uti[ — � Or EwsnNG
FENCE
P 3
I100 641 I GEOTECHNICAL, INC. I LOCATION OF PERCOLATION TEST HOLES I Fig. 1
WORTH-PAWLAK GEOTECHP*L, INC.
TABLE
PERCOLATION TEST RESULTS JOB NO. 100 641
Page No. 1 of 2
HOLE NO.
HOLE DEPTH
(INCHES)
LENGTH OF
INTERVAL
(MIN)
WATER DEPTH
AT START OF
INTERVAL
(INCHES)
WATER DEPTH
AT END OF
INTERVAL
(INCHES)
DROP IN
WATER
LEVEL
(INCHES)
AVERAGE
PERCOLATION
RATE
(MINJINCH)
P-1
50
15
9
8 '/4
/.
60
8 3/4
8 '/2
8 'h
8
/.
8
7%
%
7 3/.
7 'h
/.
7'h
7'h
/4
7 '/4
7
/.
7
8 %/4
P-2
29
15
water added
7 'h
6 'h
1
7
14
6 'h
4 %
l %
4 %
3 'A
1 %a
8 'h
7 %
1 '/4
7 '/4
6
1 '/4
6
5
1
5
3%
1'/4
3%
2%
1
P-3
47
15
10
9
1
30
9
8 1111
/I
8 'h
8
'A
8
7X
h
7 'h
71/,
%
7 '/.
6 %
h
6 Y.
6 'h
h
6 Y4 1
5 '/4
Y: 1
Note: Percolation test holes were hand dug in the bottom of backhoe pits and soaked on August
3, 2000. Percolation test were conducted on August 4, 2000. The average percolation
rates were based on the last three readings of each test.
PWORTH-PAWLAK GEOTECH 'WL, INC.
TABLE
PERCOLATION TEST RESULTS JOB NO. 100 641
Page No. 2 of 2
HOLE NO.
HOLE DEPTH
(INCHES)
LENGTH OF
INTERVAL
(MIN)
WATER DEPTH
AT START OF
INTERVAL
(INCHES)
WATER DEPTH
AT END OF
INTERVAL
(INCHES)
DROP IN
WATER
LEVEL
(INCHES)
AVERAGE
PERCOLATION
RATE
(MINANCH)
P-4
32
15
1014
9 '/.
1
30
8 '/2
8
Y:
8
7 '/:
/,
7 '/a
7
h
7
6 '/2
%
6 '/2
6
/2
6
5'/,
h
Note: Percolation test holes were hand dug in the bottom of backhoe pits and soaked on August
3, 2000. Percolation test were conducted on August 4, 2000. The average percolation
rates were based on the last three readings of each test.
i
Sep -07-00 03:50A
%MUELSON PUMP CO. INC.0
P.O. BOX 297 WATER SYSTEMS
GLENWOOD SPRINGS SALES, SERVICE 8 INSTALLATION
COLORADO 61602 945-6309
July 7, 2000
Kate McBride
303E AABC
Aspen, Co. 81611
Attn: Kate
On June 29, 2000 a well test was conducted on a well on the Light Ranch
at 5459 E. Sopris Creek Rd. The following information was obtained;
Well Depth approx------------------------------- 30'-0"
Casing size(top)------------------------------- 5"(steel)
Standing water level ----------------------------- 8.35'
Drawdown ® 21 gpm---------------------------10.1'
Total test time------------------------------------ 2 hrs.
Production is -------------------------------------21 gpm.
This test was conducted with the existing pump and related equipment.
The well recovered back to 8.90' in 6 min. If you have any questions please
call me, Raun Samuelson at 970-945-6309.
Sincerely;
le2 „w
Raun Samuelson
FAx- 425-21011
(Ci
THIS DRAWING SHOWS ALL EXISTING WELLS WMTHIN SETBACK A. CALCULATIONS GENERAL NOTES
--DIS7I+NCFS INCLUDING ON SURROUNDING PROPERhES), CONTOUR INTERVALS, D 1 -7 1. THE INFILTRATOR BED SHALL BE, LEVEL (+ 0.1 FEET
\ ALL PROPOStD AND EXISTING BUILDINGS, PROPERTY LINES, DITCHES, SLOPES 1. STANDARD FLOW = 3 BDRM X 2 PERSONS/BDRM X 100 GPD/PERSON = 600 GPD d E1✓y BACKFILL MUST PROVIDE POSITIVE DRAINAGE AWAY FROM THE BED.
OF GREATER THAN 15% WATER LINES, SPRINKLER SYSTEMS, SPRINGS, SUCTION Z. DESIGN FLOW = 600 X 1.75 = 1,050 GPD
(IRRIGATION)lLINES, DRINKING WATER CISTERNS, DRAIN POLES, IRRIGATION DITCHES, Q I 6 ✓ P
.. \ LAKES, PffNDS, WATER COURSES, STREAMS, LOOJPLAiNS, FLOOD WA YS, DRY 3. REQUI6ED•SEPTIC TANK CAPACITY = 7,050 X 1.25 = 1,313 GALLONS THE SEPTIC TANK SHALL BE LOCrATED AT LEAST FIVE FEET AWAY FROM THE RESIDENCE
c AE` 7W0 COMPA CRETE SEPTIC TANK 3 THE PIPE FROM THE RESIDENCE TO THE TANK MUST BE INSTALLED AS FOLLOWS:
GULCHES, OR EXISTING SEPTIC S'Y5TZM-SS, -IND ALL SUCH FEATURES ON THE PIPE MUST BE INSTAL ED STRAIGHT IN ALIGNMENT AND GRADE.
NEIG✓yBORING PROPERTIES WYFHIN SETBACKS. 2 ll,
4. REQUIRED SAND BED AREA = 2 600 / ( 0.95 GALLONS / SF / DAY) = 63 SF T A CHANGE T E I ALIGNMENT OR GRADE IS NECESSARY, A CLEAN OUT WILL BE REQUIRED AT THE CHANGE.
SAND BED AREA PROVIDED = 4 * 32. = 1746 v!' \ THE MINIMUM GRADE OF THE PiPE MUST BE 1/4" PER FOOT.
5. ABSORSTION AREA REQUIRED = A = 1050/5 : / 1 0 = 1.225 SF THE PIPE MUST BE A MINIMUM OF ASTM 2729 PVC PIPE, IF THE LINE CROSSES A VEHICULAR ACCESS,
THE PIPE SPECIFICATION SHALL BE CHANGED 70 ASTM 3034 PVC OR BETTER.
1 / 7
6. INFILTRATOR BED INSTALLATION: 1� \ A MINIMUM OF 1 CLEAN 0 T SHALL BE INSTALLED AT THE LOCATION WHERE THE PIPE LEAVES THE RESIDENCE.
/
\
\ PER UNIT = 79 UNITS MIN. 1,225 S0. FTHE PIPE SHALL BE A MINIMUM OF 4" IN DIAMETER.
T./ 15.5 SOFT. T'•\
THE PIPE FROM THE SEPTIC TANq TO THE INFILTRATION BED SYSTEM MUST BE INSTALLED AS FOLLOWS:
80 UNITS PROVIDED IN A 8 UNIT X 10 UNIT CONFIGURATION
8. WELL SETBACK DISTANCE NF\��P qD\NO` \ THE MINIMUM SLOPE OF THE LINE MUST BE 1/4" PER FOOT.
THE PIPE SHALL BE A MINIMUM OF ASTM 2729 PVC PIPE. IF THE LINE CROSSES A VEHICULAR ACCESS,
\ 100 + 8 ` ((1050-1000)/100) = 104 FEET OE Or THE PIPE SPECIFICATION SHALL BE CHANGED TO ASTM 3034 PVC OR BETTER.
\ 7 o- THE PIPE SHALL BE A MINIMUM OF 4" IN DIAMETER.
/ 9. DITCH, STREAM AND POND SETBACK DISTANCE 0 60
\ \ 50 + 8 A ((1050-1000)/100) = 52 FEET SRPSGR C5 OE��� \ USE RiSERS TO BRING THE SEPTIC TANK ACCESS WITHIN 6" OF FINAL GRADE.
0, WATERLINE SETBACK DISTANCE Q \NF\� �QR 5a r6. ALL MATERIALS, INSTALLATION PRACTICES AND SETBACK REQUIREMENTS SHALL
\ \ 10 FEET TO TANK, 25 FEET TO FIELD LVDN \�1RP - \ COMPLY WITH PITKIN COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS.
OF \NF 7. INFILTRATOR COMPONENTS TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS.
1 P 8°jj0M
oP SYSTEM DESCRIPTION
THIS SYSTEM IS AN INFILTRATOR SAND BED FILTER TYPE.
\ f !{ CONCRETE I: TANK IS PEOUIRED
EFFLUENT IS TRANSFERRED FROM'SEPi1C TANK TO A DISTRIBUTION BOX AND FROM THERE
O r' IS DISTRIBUTED THRU A 4" 0 PIP'NG MANIFOLD TO THE INFILTRATOR ARRAY ON A SAND BED
AS SHOWN ON THE PLAN.
INSTALL INSPECTION PORTS AT ALL 4 CORNERS / \ e 1 GENERAL INSTALLATION PROCEDURES
s jj\ _/ J POPE OFF THE SITE TO PREVENT DAMAGE TO THE AREA DURING OTHER CONSTRUCTION ACTIVITY ON THE LOT.
VEHICULAR TRAFFIC OVER THE AREA SHOULD BE PROHIBITED TO AVOID SOIL COMPACTION.
STAKE OUT FIELD PERIMETER AND INFILTRATOR BED IN THE PROPER ORIENTATION AS SHOWN.
`�\ �, �` �\ ` CUT AND REMOVE ANY EXCESSIVE VEGETATION, TREES SHOULD BE CUT AT GROUND SURFACE AND THE STUMPS
i i t Y Q LEFT IN PLACE
11 T ` 4. REMOVE SOIL TO PROVIDE FOR SAND BED TO EXTEND 2 F7 BEYOND INFILTRATOR ARRAY.
/ DITCH k CREEK SETBACKJ"'� � I � �
/ D i 5. PLACE THE SAND FILL OVER THE BASAL AREA, KEEP TRUCKS OFF THE ROUGHENED AREA. MOVE THE FILL INTO PLACE
y USING A SMALL TRACK TYPE TRACTOR WITH A BLADE OR A LARGE BACKHOE WITH ENOUGH REACH TO ACCOMMODATE
THE DIMENSIONS OF THE SAND BED. FINAL SAND DEPTH IS FOUR (4) FEET ABOVE THE MOTTLED LAYER.
. INSTALL PERF PIPE CONTAIN SAND EDGES WITH BACY,FILL MATERIAL AND FLOOD THE SAND TO SETTLE AND CONSOLIDATE
\ \ a FOR IST 10 FEET LEVEL THE SAND BED AND INSTALL INFILTRATORS AND DISTRIBUTION PIPING PER INFILTRATOR RECOMMENDATIONS
FIELD LOCATION _' , WELL SE TBA -K cr I PLACE THE DISTRIBUTION BOX ONI CRUSHED ROCK. INSTALL THE DISTRIBUTION PIPES FROM THE DISTRIBU7ON BOX.
4 ` 0 O �•, 1 Q BACKFILL BETWEEN INFfLTRATORS BY "WALKING IN" THE TOPSOIL AND COMPLETE MOUND SLOPES.
PROVIDE FOR FROST PROTEC71ON BY ADEQUATE BACKFILL AROUND PIPING AND EFFLUENT LINE OR PROVIDE
# INSTALL ON 3" SCREENED ROCK FILL o ALTERNATE PROTECTION WITH INSJLATION.
WELL SETBACK o APPROXIMATE MOUND EDGE PROVIDE POLYLOK FLOW ADJUSTERS a , PROVIDE DITCHES ABOVE THE FIELD TO DIVERT WATER FLOWS AROUND THE FIELD.
/►' �i, \� _� ON ALL DISTRIBUTION PIPES PLANT NATIVE GRASSES OVER THE ENTIRE MOUND. SHRUBS CAN BE PLANTED AROUND THE BASE AND UP THE SIDE
SLOPES SHRUBS SHOULD BE SOMEWHAT MOISTURE TOLERANT SINCE DOWN SLOPE PERIMETER MAY BECOME WET DURING
UH EARLY SPRING AND LATE FALL. PLANTINGS ON TOP OF THE MOUND SHOULD BE DROUGHT TOLERANT, AS THE UPPER
4" SCHED 40 3
, PORTION OF THE MOUND CAN BECOME DRY DURING THE SUMMER
INSULATE AS REOD� M
SEPTIC TANKS
1 ONE 7,500 GALLONW-n"FIF WICOMPA1f'FMFN•T, SEPfi'C !AHK IS REQUIRED FOR THIS SYSTEM.
THE SEPTIC TANK SHALL BE LOCATED AT LEAST FIVE FEET AWAY FROM THE RESIDENCE
CLEANOUT WITHIN 2' OF' -OUSE \ 3. USE RISERS TO BRING THE SEPTIC TANK ACCESS WITHIN 6" OF FINAL GRADE.
_ 1
4 THE INLET INVERT SHALL BE A7 LEAST 3 INCHES HIGHER THAN THE OUTLET INVERT.
I THE DISTANCE FROM THE OUTLETINVERT TO THE UNDERSIDE OF THE TANK TOP SHALL BE AT LEAST 10 INCHES.
7. LIE UNDERSIDE-
DEED FTHE �A�MICiUG OF 30 INCHFS�ANGE HEMAX�'IM14 INCHES 9E{ALLO J07 E ET INCH OF
I WITHIN ONE
J CE Si �;TAI�1�°d6£ 01�' 7 INVERT. _
1 THE TANK LENGTH OR 60 INCHES WHICHEVER IS LESS.
THE TRANSFER OF LIQUID FROM 'NE FIRST COMPARTMENT TO THE SECOND SHALL BE MADE A7 A LIQUID
�I( \
SEE TANK DE7Ali_ C I \ DEPTH OF AT LEAST 14 INCHES OELOW THE OUTLET INVERT, BUT NOT IN THE SLUDGE ZONE.
BE PROVIDED IN EACH COMPARTMENT
THE CLEAN OUT MUST BE LOCATED WITHIN TWO FEET OF THE RESIDENCE
I FT MINIMUM COVER OVER INFILTRATOR THE PIPE SHALL BE A MINIMUM OF 4" IN DIAMETER.
I FT MINIMUM COVER OVER INFILTRATOR
a LTH�E� PIPE FROM THE SEPTIC TANK TO THE DISTRIBUTION BOX SHALL 8E 4 INCH DIAMETER.
5 [tE {3T,1iitBUTION MORE INSIDE 71 IN BIlA6� HOLES ORIENTED DOWNWARD
j:l MAxIMUM SLOPE - 3:1 MAXIMUM SLOPE 6. THE DISTRIBUTION PIPE SHALL BE PLACED AS SHOWN IN DETAILS. PROVIDE OPENING AT THE BASE Q"
POSITIVE DRAINAGE 4% r POSITIVE DRAINAGE 4% 1 / THE INFILTRATOR END PLATES TC ALLOW THE DISTRIBUTION PIPING TO LAY ON THE SAND SURFACE
--- �// INFILTRATORS
INFILTRATORS TO BE H-10 STYLE
�- 2. INFILTRATOR INSTALLATION TO COMPLY WITH MANUFACTURERS RECOMMENDATIONS
3. INSTALL INSPECTION PORTS AT THE CORNERS OF THE FIELD.
I
INSTALL PERF PIPE FOR 151 tC Fr
FF,7A7
T
" IN STALL I,-ry
9.
LEAST ONE ACCESS NO LESS THAN 20 INCHES ACROSS SHALL
TOP OF SAND TO BE 56' BELOW BOTTOM OF SIDING
SEE SPECS, FOR SAND GRADE
10.
ALL MATERIALS, INSTALLATION PF,'ACTICES AND SETBACK REQUIREMENTS SHALL COMPLY WITH
J \
\
\
c-
�a I
PITKIN COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS.
I
W
PLASTIC TEE INSTALLED TO
UPPER �XTENSIOIN OF INLET
__7LEEES
7
BE VISIBLE FROM MANHOLE
6 IN. MAX BACKFlIL !
PIPING
z�
o
/ OPENING COVER OF M
TYYPPICAL
i
WATER LE -TO
THE WALL SHALL
jANHOLE
BOTTOM OF FLUID
XTENSION TRANSFE-
1.
WHERE PLASTIC PIPE AND FITTINGS ARE USED, MINIMUM THICKNESS OF THE PiPE
.
°'SITIVE POji7,rE MAXIMUM SL CPE
°FAI,NAGE DRAINAGE
CONFORM TO ASTM STANDARD .5034, SDR35 OR EQUIVALENT.
TANK !DIODEP.
TTTIIIOL�N�A
\
@ "� t 0 43 s
\
p�Fp [EEFNN'�q LEE�pRESC
HIOnypy WA
pTFERT
AWL
2
ALL WASTEWATER LINES SHALL PE CONSTRUCTED OF COMPATIBLE PIPE, BONDING AGENT AND FITTINGS.
\
SEPTIC TANK DETAIL
3
THE PIPE FROM THE RESIDENCE tO THE TANK MUST BE INSTALLED AS FOLLOWS.
SAISTING GRubND-
/ i
\
\..4 FT SAND BED 0" EXISTING MOTTLED LAYER
\
THE PIPE MUST BE INSTALLED STRAIGHT IN ALIGNMENT AND GRADE.
% � l SGitL�- III
� ZJVr
1'-0' MIN. SEE SPECS. F)R SAND GRADE. 1•-G' MIN.
I
5GAIX:Irl 20'
Ter -
IF A CHANGE IN ALIGNMENT OR (sRADE IS NECESSARY, A CLEAN OUT WILL BE REQUIRED AT THE CHANGE.
SEC TI ON B
1
-iLALE- _ I.
THE MINIMUM GRADE OF THE PIPrr MUST BE 1/8" PER FOOT, THE MAXIMUM GRADE IS 1/4" PER FOOT
7
A MINIMUM OF I CLEAN OUT SHALL BE INSTALLED AT THE LOCATION WHERE THE PIPE LEAVES THE RESIDENCE
THE CLEAN OUT MUST BE LOCATED WITHIN TWO FEET OF THE RESIDENCE
I FT MINIMUM COVER OVER INFILTRATOR THE PIPE SHALL BE A MINIMUM OF 4" IN DIAMETER.
I FT MINIMUM COVER OVER INFILTRATOR
a LTH�E� PIPE FROM THE SEPTIC TANK TO THE DISTRIBUTION BOX SHALL 8E 4 INCH DIAMETER.
5 [tE {3T,1iitBUTION MORE INSIDE 71 IN BIlA6� HOLES ORIENTED DOWNWARD
j:l MAxIMUM SLOPE - 3:1 MAXIMUM SLOPE 6. THE DISTRIBUTION PIPE SHALL BE PLACED AS SHOWN IN DETAILS. PROVIDE OPENING AT THE BASE Q"
POSITIVE DRAINAGE 4% r POSITIVE DRAINAGE 4% 1 / THE INFILTRATOR END PLATES TC ALLOW THE DISTRIBUTION PIPING TO LAY ON THE SAND SURFACE
--- �// INFILTRATORS
INFILTRATORS TO BE H-10 STYLE
�- 2. INFILTRATOR INSTALLATION TO COMPLY WITH MANUFACTURERS RECOMMENDATIONS
3. INSTALL INSPECTION PORTS AT THE CORNERS OF THE FIELD.
I
GROUND
1. THE SAND SHALL BE CLEAN, CO;RSE SAND, ALL PASSING A SCREEN HAVING 4 MESHES TO THE INCH
2. THE SAND SHALL HAVE AN EFFE,-TIVE SIZE BETWEEN .25 AND .6 MILLIMETER (mm).
3. THE UNIFORMITY COEFFICIENT SHALL BE 4.0 OR LESS.
4. THE SAND SHALL BE AT LEAST fGYMT DEEP ABOVE THE MOTTLED LAYER, 58' BELOW THE BOTTOM OF HOUSE
5 THE SAND SHALL EXTEND 2 FEE' BEYOND THE EDGE OF THE INFILTRATORS.
6. THE SAND MUST BE TH0POJGH--9PLED BY FLOODING BEFORE THE IHkiLTRATORS ARE PLACED
7. THE TOP OF THE SAND RED ShIA 3L LLbE.
FINISH GRADING
TOPSOIL COVERING THE INFILTRATORS MUST HAVE A MINIMUM DEPTH OF 1 FOOT AT EDGES
SEE DETAILS A AND B.
THE FINAL SLOPE OF BACKFILL SHALL BE NO GREATER THAN 2:1 (RUN:RISE).
3. FOLLOW INFILTRATOR RECOMMENIA77ONS FOR BACKFILL PROCEDURES,
4 ALL MATERIALS, INSTALLATION PF;ACTiCES AND SETBACK REQUIREMENTS SHALL
COMPLY WITH PiTKIN COUNTY INDVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS,
NOTE:
WATERLINE CROSSINGS REQUIRE THAT THE DRINKING WATER OR
WASTEWATER PIPE BE ENCASED FOR AT LEAST TEN (10) FEET
OF EACH SIDE OF THE CROSSING OR PLACE WHERE COMPONENTS
ARE CLOSER THAN TEN (11') FEET. PIPE OF SCHEDULE 40 RATING
OR BETTER MUST BE USED OF SUFFICIENT DIAMETER TO EASILY
SLIDE OVER AND COMPLETELY ENCASE THE LINE, RIGID END CAPS
OF AT LEAST SCHEDULE 40 RATING MUST BE GLUED OR SECURED
IN A WATERTIGHT FASHION TO THE ENDS OF THE ENCASEMENT
PIPE. THERE MUST BE A, MOLE OF SUFFICIENT SIZE TO ACCOMMODATE
THE PIPE IN THE LOWERMOST SECTION OF THE RIGID CAP SO THAT
THE CONVEYANCE PIPE RESTS ON THE BOTTOM OF THE ENCASEMENT
PIPE. THE AREA IN WHICH THE PIPE PASSES THROUGH THE END CAPS
MUST BE SEALED WITH AN APPROVED UNDERGROUND SEALANT
COMPATIBLE WITH THE PIR,,IG USED.
®�DRhDo I FC/s lil
rFOi
OPC11410 N :SII
1 c�.o �
5 �5
i Oa
�h A•` IGEN
COPYRIGHT
( I DRAWN BY
DP7
DATE
9//8/00
REVISIONS
SCALE
h5 ShOWN
DRAWING
5, 0, 5,
1�f5/6IV
L)frA/LS
Of NN 7-f -`5
SHEET
INSTALL PERF PIPE FOR 151 tC Fr
2'-G' MIN. 4 FT SAND BED OVER MOTTLED LAYER 2-O MNJ,
TOP OF SAND TO BE 56' BELOW BOTTOM OF SIDING
SEE SPECS, FOR SAND GRADE
SECTION A
" = 10'
�a I
i
PLAN
-
W
PLASTIC TEE INSTALLED TO
UPPER �XTENSIOIN OF INLET
__7LEEES
7
BE VISIBLE FROM MANHOLE
6 IN. MAX BACKFlIL !
ANp EX SHALL BE
WITHIN 1 MI. OF TOP OF TANK
z�
o
/ OPENING COVER OF M
TYYPPICAL
i
WATER LE -TO
jANHOLE
BOTTOM OF FLUID
XTENSION TRANSFE-
- `-T
OF
tiDON
.
°'SITIVE POji7,rE MAXIMUM SL CPE
°FAI,NAGE DRAINAGE
TANK !DIODEP.
TTTIIIOL�N�A
@ "� t 0 43 s
p�Fp [EEFNN'�q LEE�pRESC
HIOnypy WA
pTFERT
AWL
?IR L.RNE CO�MECTIONS TO TANK.
SEPTIC TANK DETAIL
_ 4�E
SAISTING GRubND-
\
\..4 FT SAND BED 0" EXISTING MOTTLED LAYER
TOP OF SAND TO BE 58• BELOW BOTTOM OF SIDING
1'-0' MIN. SEE SPECS. F)R SAND GRADE. 1•-G' MIN.
Ter -
SEC TI ON B
-iLALE- _ I.
GROUND
1. THE SAND SHALL BE CLEAN, CO;RSE SAND, ALL PASSING A SCREEN HAVING 4 MESHES TO THE INCH
2. THE SAND SHALL HAVE AN EFFE,-TIVE SIZE BETWEEN .25 AND .6 MILLIMETER (mm).
3. THE UNIFORMITY COEFFICIENT SHALL BE 4.0 OR LESS.
4. THE SAND SHALL BE AT LEAST fGYMT DEEP ABOVE THE MOTTLED LAYER, 58' BELOW THE BOTTOM OF HOUSE
5 THE SAND SHALL EXTEND 2 FEE' BEYOND THE EDGE OF THE INFILTRATORS.
6. THE SAND MUST BE TH0POJGH--9PLED BY FLOODING BEFORE THE IHkiLTRATORS ARE PLACED
7. THE TOP OF THE SAND RED ShIA 3L LLbE.
FINISH GRADING
TOPSOIL COVERING THE INFILTRATORS MUST HAVE A MINIMUM DEPTH OF 1 FOOT AT EDGES
SEE DETAILS A AND B.
THE FINAL SLOPE OF BACKFILL SHALL BE NO GREATER THAN 2:1 (RUN:RISE).
3. FOLLOW INFILTRATOR RECOMMENIA77ONS FOR BACKFILL PROCEDURES,
4 ALL MATERIALS, INSTALLATION PF;ACTiCES AND SETBACK REQUIREMENTS SHALL
COMPLY WITH PiTKIN COUNTY INDVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS,
NOTE:
WATERLINE CROSSINGS REQUIRE THAT THE DRINKING WATER OR
WASTEWATER PIPE BE ENCASED FOR AT LEAST TEN (10) FEET
OF EACH SIDE OF THE CROSSING OR PLACE WHERE COMPONENTS
ARE CLOSER THAN TEN (11') FEET. PIPE OF SCHEDULE 40 RATING
OR BETTER MUST BE USED OF SUFFICIENT DIAMETER TO EASILY
SLIDE OVER AND COMPLETELY ENCASE THE LINE, RIGID END CAPS
OF AT LEAST SCHEDULE 40 RATING MUST BE GLUED OR SECURED
IN A WATERTIGHT FASHION TO THE ENDS OF THE ENCASEMENT
PIPE. THERE MUST BE A, MOLE OF SUFFICIENT SIZE TO ACCOMMODATE
THE PIPE IN THE LOWERMOST SECTION OF THE RIGID CAP SO THAT
THE CONVEYANCE PIPE RESTS ON THE BOTTOM OF THE ENCASEMENT
PIPE. THE AREA IN WHICH THE PIPE PASSES THROUGH THE END CAPS
MUST BE SEALED WITH AN APPROVED UNDERGROUND SEALANT
COMPATIBLE WITH THE PIR,,IG USED.
®�DRhDo I FC/s lil
rFOi
OPC11410 N :SII
1 c�.o �
5 �5
i Oa
�h A•` IGEN
COPYRIGHT
( I DRAWN BY
DP7
DATE
9//8/00
REVISIONS
SCALE
h5 ShOWN
DRAWING
5, 0, 5,
1�f5/6IV
L)frA/LS
Of NN 7-f -`5
SHEET
fRA�OR
SE OF INF11' O� OIOINO
ODOR @ BA
g000W
80O�OM
OND INFI��R R 5
8„
ND 2' 600 INFI��RA�O
OF S A OF
OINE OD �gOO�OM
OO�
S A co lb
lop
\ 1
80 H-10 INFILTRATOR UNITS
INSPECTION PORTS AT ALL 4 CORNERS
\ 1
31.2
D
SN
�\
U
WELL
0
APPROXIMATE MOUND EDGE
12 PORT "D" BOX
'LOK FLOW ADJUSTERS
CLEANOUT WITHIN 2' OF HOUSE
-1-
0
C
N
cp.
1
11
45.6
DERF PIPE
FOR 1ST 10 FEET
0
1~
23 =
0
N
I
I
0
0
0
p'P��pO REGiSIa,
Vol' jp
25851
...........;r
COPYRIGHT
b
DRAWN BY
DP
ao
O q.
Iz- U u u
O o�o
� � U
u,i Z
DATE
REVISIONS
SCALE
11140'
DRAWING
�S-DUILT
SHEET