Aspen/Pitkin Environmental Health Department
Permit for an Individual Sewage Disposal System
130 S. Galena St. Aspen, Colorado 81611
Phone 970-920-5070 / FAX 970-920-5074
Permit # 20003 Parcel ID #
Type of permit New( ) Failure( ) Addition to House( X )
Name of Owner Robert A. Brod
Street Address 1285 Snowmass Ck Rd
Property legal description Lots 2 & 4, O -Be -Joyful Acres
Size of lot 4.7 Total square footage of the house 5,000
Water source Private Well
# of bedrooms in house 4 # of offices, lofts & similar sized rooms in house
Caretaker unit Total square footage of the caretaker unit
# of bedrooms in caretaker unit # of offices, lofts & similar sized rooms in caretaker unit
TO c` (lisf)', FQ,(JRmi4}-SEptiC�l�Dtt31
Permit information
Designed by Dean Derosier
Mailing Address 111 P AABC, Aspen
Perc rate na Profile hole depth Depth to groundwater or bedrock 4 ft
Septic tank capacity 1,750 total Absorptiorfarea 1,167 sq ft
Comments
Septic permit approved per compliance with the engineer design and specifications dated February 1, 2000 and
memo with initialed strikeouts dated February 9, 2000. Any changes must be approved by this department and
the design engineer prior to them being made.
Design is to add a 750 gallon septic tank in series between the existing 1,000 gallon septic tank and existing 1,000
gallon dosing tank. The existing mound is to be enlarged to 1,167 sq. ft.
Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin
County ISDS regulations. The proposed mound is 124 ft from the well, not the required 132 ft. The engineer has
included a statement that the well will not be contaminated.
This department does not endorse any brand of products.
The engineer must do a final inspection of the installation and submit an as -built letter to this department. This
department must also be called for an inspection with a minimum of 48 hours advanced notice.
Permit approved by: h4tc C Date: od
Plans and specifications of the pr sed individual age disposal systeni havd been reviewed and are considered
satisfactory. Permission is hereby ranted to the owner or the agent to perform the work indicated in accordance with the Pitkin
County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was
issued unless system construction has commenced or an extension has been approved in writing by the Department.
As -built drawings must be includ with this permit before the final approval will be Issued.
Installer: A u (a/1 VIA -MA iM
iriah3rispecdonapproval: int bid Dat°. ,'.
�� uueC� Ir1w1 Q,4 - low H �rom ulgek c -r;
ASPSKIN ENVIRONMENTAL HEALTH RTMENT
APPLICA ON FOR INDIVIDUAL SEWAGE DISTAL SYSTEM
130 S. Galena St., Aspen Colorado 81611
Phone 970-920-5070/Fax 970-920-5074
Name of OWNER '5 � A , �V)
Owner's Mailing Address (' /,1)-t 7 c n; /Ztf - Su �o i S{ 4,1
Business Phone: Home Phone: 63 // 7
Primary Contact Person (all communication regarding this permit will go through this person)
Name (—
Company .
Contact Mailing Address S
Business Phone : qtfL,�-Cell PhoneL%`L Fax : 6
Parcel ID # (available from assessors office pp ']
at 920-5160 or at www.aspen.com/assessorq b
Street address of property ) "; ST J/V D u-1 ;.-A !45S
Legal Description: Lot �- ,Block Filing Subdivision 0-i�.
Size of lot: q13—acres. Type of proposed structure: C . F1Z. Size of bldg. envelope:
Total square feet of house 5 j 000 # of bedrooms in house
# of offices, lofts & similar sized rooms in house
Caretaker Unit: Attached ( ) Detached ( ) Total area(sq. ft.) of caretaker unit
# of bedrooms in caretaker unit # of offices, lofts and similar size rooms of caretaker unit
Permit is for: New Home ( ) Repair due to failure ( ) Remodel/Addition ( )�) Emergency use ( )
Water: Private well ( ) Spring ( ) Stream ( ) Community/Public Water System (x)
If community system: Name of system
The fee for a ISDS application is $330 for a permit that takes 6 hours or less for the department to approve. If approval takes
longer than 6 hours, a rate of $55 per hour will be charged. The maximum fee is $1000. The basic fee of $330 is due at the time
of application. The remainder, if any, will be due in two stages: first, at the time of issuance of the ISDS permit; second, before
final approval of the ISDS permit.
Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information is true and
accurate and that I have provided true and accurate information on locations of all existing and proposed wells, contour
intervals, buildings, property lines, ditches, slopes, watedines, springs, suction or irrigation lines, drinking water cisterns, drain
tiles, irrigation ditches, lakes, water courses, streams, fioodplains, dry gulches, and existing septic systems. I hereby certify
that any such features not shown on attached site map are not present. Issuance of the permit does not imply the approval of
any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all
approvals and permits have been obtained.
The Aspen/Pitkin Environmental Health Department, Pitkin County and employees of these agencies will be held harmless
should the individual sewage disposal system fail or malfunction. The permit to construct is issued on information submitted by
the applicant or his/her representatives. The owner assumes fyll responsibility in case of failure of the system.
Signature of applicant
Received by
-X G[ tPh\iSrl%UnrlS;
r / ) 6 n
P—fJ
-A, Date
# Jq .'ate
i
V
9.1
o
OS
Legal Description: Lot �- ,Block Filing Subdivision 0-i�.
Size of lot: q13—acres. Type of proposed structure: C . F1Z. Size of bldg. envelope:
Total square feet of house 5 j 000 # of bedrooms in house
# of offices, lofts & similar sized rooms in house
Caretaker Unit: Attached ( ) Detached ( ) Total area(sq. ft.) of caretaker unit
# of bedrooms in caretaker unit # of offices, lofts and similar size rooms of caretaker unit
Permit is for: New Home ( ) Repair due to failure ( ) Remodel/Addition ( )�) Emergency use ( )
Water: Private well ( ) Spring ( ) Stream ( ) Community/Public Water System (x)
If community system: Name of system
The fee for a ISDS application is $330 for a permit that takes 6 hours or less for the department to approve. If approval takes
longer than 6 hours, a rate of $55 per hour will be charged. The maximum fee is $1000. The basic fee of $330 is due at the time
of application. The remainder, if any, will be due in two stages: first, at the time of issuance of the ISDS permit; second, before
final approval of the ISDS permit.
Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information is true and
accurate and that I have provided true and accurate information on locations of all existing and proposed wells, contour
intervals, buildings, property lines, ditches, slopes, watedines, springs, suction or irrigation lines, drinking water cisterns, drain
tiles, irrigation ditches, lakes, water courses, streams, fioodplains, dry gulches, and existing septic systems. I hereby certify
that any such features not shown on attached site map are not present. Issuance of the permit does not imply the approval of
any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all
approvals and permits have been obtained.
The Aspen/Pitkin Environmental Health Department, Pitkin County and employees of these agencies will be held harmless
should the individual sewage disposal system fail or malfunction. The permit to construct is issued on information submitted by
the applicant or his/her representatives. The owner assumes fyll responsibility in case of failure of the system.
Signature of applicant
Received by
-X G[ tPh\iSrl%UnrlS;
r / ) 6 n
P—fJ
-A, Date
# Jq .'ate
By: McLaughlin Water Engine&Ltd; 970 925 1974;
Feb -9-0^ 11:03AM; Page 1/1
so
McLAUGHUN WATER ENGINEERS, ltd.
111 1' AABc ASPFN, cO1.ORADO 51611
970-925.1920 970-925.1974 fax mweaspvnCiififf net
MEMORANDUM
Data: February 9, 2000
To: Pitkin County Environmental Health, Nancy M.
From; Dean Derosisr; McLADGHLIN Water Rngineers, Ltd.
RE: Brod Residence - Septic System Design - PCEH Comments
Nancy:
Distance from existing wells. The existing system is 150 feet from an
existing well. The regulations require an additional 8 feet for every 100
gallons over 1,000 gallons. Flow = 4 . 4 bed rooms x z pea/br x 100
gal/day/per x 1.75 = 1,400 gallons per day, this equates to an additional 32
feet, or requiring 132' from the well. The proposed system is a Mound System
and is 124 -feat away from the well at the edge of the fill area and-440—feet
,drom the actual disposal area of the system. So I don't think it's really an
tissue, as ws meet the actual 132' minimum distance requirement to the disposal
area with the design of the system.
Based on the geological conditions and evaluation of risk of contamination of
the well, I am not concerned about the 124 -foot horizontal distance from the
well to the fill area in providing an adequate level of safety against
contamination. I believe the 124 -foot separation between the edge of the fill
and- — — * -- --1-absorptros-area-and the well is appropriate.
I hope these clear up the design and any other issues you may have.
Please call with any other questions you may have.
G. Deap' a eie r,
gdd' 2\�
Iti
By: McLaughlin Water Engineers, Ltd; 970 925 1974;
•
Jul -26-00
•
2:13PM;
Page 1/1
MVff McLAUGffl, N WATER ENGINEERS, ltd
I l l F AA13C ASPEN, COLORADO 81611
970-925.1920 970-925-1974 fax mwcaaj�i(ajotnet
MEMORANDUM
Date; July 26, 2000
To: Pitkin County Environmental Health, Nancy M.
From: Dean Derosiery MCLAVGHLIN water Engineers, Ltd.
RE: Brod Residence - Septic System Design - FINAL
Nancy:
The BROD Residence septic system was installed placed into service in June of
2000. MWE and GDD have inspected the installation of the system and find it
was installed according to MWE's design and PCBH requirements. Slight
modifications were made to maintain the 126' clearance from the well to tha
edge of the field and 132' to the actual system, (IE - The system was moved
-10' east of the proposed location shown on the drawing). This letter is to
serve as theac p(i] ee letter for MWE and recommendation to Pitkin County for
pF. ,
final ystem.
Please questions
P.
gdd \broaFNL\KQ4iECpp;".n,;;
McLAUGHLIN WATER ENGINEERS, Itd.
I I I P AABC ASPEN, COLORADO 81611
970-925-1920 970-925-1974 lax mweaspen(a)roflie[
MEMORANDUM
Date: February 1, 2000
To: Pitkin County Environmental Health;
From: Dean Derosier; McLaughlin Water Engineers, Ltd.
RE: Brod Residence - Septic System Design Notes-SNOWMASS CREEK -
AO -003.01
The following are my design notes for the addition to the Brod Residence
Septic System design. The site is a flat area next to the home along Snowmass
Creek. This system is an addition to the existing system.
4 - Bedrooms
Approx. 3,000 Square Feet of living area
- 100 gallons per day per person
- A percolation test was not performed as ground water is 4' below existing
grades.
Ground water 4'+\- feet from a surface
Flow = Q = 4 bed rooms x two per/br. x 100 gal/day/per x 1.75 = 1,400
gallons per day.
This requires the new system to be 132 -feet from the well. Existing well is
124' from the edge of the new system and 140 -feet from the actual field.
Tank sizing - 4 - Bed Rooms requires 1,750 gallons of septic tank; Q X 1.25
Reuse the existing 1,000 gallon tank and install one additional 750 -gallon
tank in series for total 1,750 gallons of septic tanks. The new system will
require reusing the existing dosing tank to pump the effluent up to the
proposed Mound system. The existing 1,000 gallon pumping tank in series with
the two septic tanks will be acceptable for this system.
Dosing/pumping tank is a 1,000 gallon single chambered dosing tank which will
allow a dosing volume of - 300 gallons per dose 2-3 times per day.
Area of Septic field required = A
A = Q\ Loading Rate of the soils to be brought in as fill. The Loading Rate,
LR = 1.2 gallons pr Sq ft. per day.
A = Q/LR = 1,400/ 1.2 = 1,167 square feet
The mound system is shown on the attached drawing and discussed in further
detail on the attached memorandum. System total size is -45' X 72', with a
disposal area 50' X 24' laid out to fit site conditions and meet all setbacks
as shown on the attached drawing. Approximately 2.44' of sand fill and 9" of
gravel will be required to be brought in to bring the system a minimum of 4'
above the ground water. Approximately 1.5' of fill will be placed on top of
the system. The design connects to the existing system and extends the system
- 18' more. The length (721) of the existing system does not change, but the
width is increased from 6' to 241. The contractor is to expose the existing
system and carefully extend all materials, (manifold pipe, gravel, sand, fill,
fabric and other materials) needed for the new system. Extend new system using
3' between laterals and 1.5' from the edges of the system to the ends of the
lateral lines
The new tank will be installed in series along side the existing tank. Tees
will be installed on both the inffluent and effluent lines of the tank, set on
the inside of the tank. Set top of line from tee within 1" of the roof of the
tank and extend line downward 12" below center line of tee. Fill tank with
water prior to backfill to check for leaks and leave water in tank for placing
the system in service. The septic tank will be a two -chambered tank and
repiped to allow the flow from the existing tank into the new tank and out,
prior to discharge into the dosing tank.
Reuse the existing manifold (2" Sch 40 PVC from the tank to the distribution
laterals) where it connects to the existing 2" sch 40 perforated PVC. The new
system will require a 1-1/2" manifold to the new 6 new 1" laterals rows.
Connect to the existing 2" manifold at the second existing lateral line with a
2" X 1-1/2" coupling and extend the new 1-1/2" manifold to each of the lateral
rows. Each row of six new laterals consists of 2 - 1" lines, 25' long, on each
side of the manifold. All piping to be bedded in a minimum of 2" under and 6"
over of 3/4" screened rock. See details and attached design memo on materials
and additional information on installation.
Adjustments to fit site contours and conditions may be made per approval of
the engineer. Elevations of the tank and trenches shall be finalized in the
field by the engineer. Installation and operation will be approved by the
engineers prior„tv. o final acceptance. System must meet all PCEH and MWE
standards,,;'
Dosing' a' ydt6 tic SPD -100H unit, (70gpm p-40'head).
5'
G. De3i1 DHro P. ,
i .
MCLAUGHUN WATER ENGINEERS, ltd.
1 I 1 P AABC ASPEN, COLORADO 81611
970-925-1920 970-925-1974 fax mweaspen@rofnet
MEMORANDUM
DATE: February I, 2000
TO: Pitkin County and Robert Brod
FROM: McLaughlin Water Engineers, Ltd.; G. Dean Derosier, P.E.
RE: Brod SEPTIC SYSTEM DESIGN - Addition
This memorandum is written to give you additional details on the design, materials, and installation of the addition
to the existing Septic System which was designed to serve the Brod home in Old Snowmass. The memorandum is
separated into three sections; I - Septic tank and Mound System design, 2 - Effluent tank design, 3 - installation
and Materials for the system. The design drawing is also attached for additional reference.
1. Septic Tank and Mound System Design:
The location of the home and the site conditions determined the required type of system which was to be designed.
The site is located just above the water table along Snowtttass Creek. The difficulties encountered dealt with the
limited area to work with and included the existing system already in place, existing trees, and high ground water
These items lead to the design of a new system which would add to the existing standard septic tank and Mound
System, and dosing system that lifts the effluent up to a flat area next to the home site for disposal. Please see my
Memorandum dated February 1, 2000 for additional information on the new system and addition to the old system
The system design was based on the ultimate construction of a 4 -bedroom residence, which required at a minimum,
1.750 gallons of septic tanks for the separation of solids and a dosing tank. The existing 1,000 gallon septic tank
can be pumped and reused, ADD an additional 750 gallon tank in series, (TOTAL 1,750 GALLONS), prior to
connection to the existing 1,000 gallon tank effluent pump/dosing tank. The dosing tank is to be cleaned and
reused with the new system, but the pump will be replaced, The new septic tank is to be a double chambered tank.
The three tanks are to be installed in a series with the septic tanks first, followed by the effluent pump tank. The
contractor will be required to connect to the existing system and use the existing elevations.
The water level, the dosing system, and the flow anticipated to utilized by the system determine the size of the
Mound System required. Using 1.2 gallons per square fool, a flow of 1,400 gallons per day requires 1,167 square
feet of septic disposal in the Mound System.
The details of the Mound System, installation, elevations, and location are shown on the attached design drawing
and sheets. The overall system size of the new system will be 45 -feet X 72 -feet. The actual field size is 24 -feet X
50 -feet. The existing system is 22' X 72' and the actual field is 6 feet wide and 50 feet long. The new system will
not increase in length (72'), but will increase in width, from 22' to 45'. The existing transmission piping and
manifold are 2 -inch and the existing distribution laterals are 2 -inch, with the laterals being perforated piping, (1/4 -
inch holes on 36 -inch centers), Sch 40, PVC. The new system will connect to the existing manifold at the second
existing lateral with a 2" X I-1/2" coupling. The new manifold will be 1 -1/2 -inch and extend to the six new lateral
lines. The laterals are to be perforated piping, (1/4 -inch holes on 60 -inch centers), with 9 -inches of gravel under
and 2 -inches of gravel over the pipe. New system is to be laid out similar to the existing with 3' between lateral
lines and 9 -inches of gravel.
N
The new system will tie directly into the existing system, using similar materials, depths, widths, cover, and other
features. The contractor will need to carefully expose the existing system, taking caution to the limit the
disturbance of the system. The new sand depth starts at the existing sand depth of 1.44 -feet and is 2.44 -feet at the
end. The sand is to be a medium sized sand with the following characteristics: 25%+ between 2.0 and 0.25mm;
30-35%- between 0.25 and 0.05mm; and 5-10% between 0.05 and 0.002mm. This sand is similar to the masonry
sand available at Roaring Fork Sand and Gravel. installation details and instructions are attached to this
memorandum. Total height of the system is -- 2.44' sand, 12" gravel, and 1.5' fill, for — '
Effluent Pumping Tank:
The existing effluent pumping tank will be reused and will be required to pump the effluent from the septic tank to
the septic field in the terrace above the home site. The tank capacity is approximately 1,000 gallons. The tank was
sized in order to get the required additional septic tank capacity and to cycle the pump operation of the system.
The new pumping system is required to pump the effluent up approximately 14 -feet of elevation difference and 26 -
feet of piping and head losses, for a total of 40 -feet of head at 70 gpm. The existing pump will need to be replaced.
The new pump we have chosen for the system is a submersible, by Hydromatic Pump, Model number SPD -100H, a
bronze pump system, with a piggyback float system. The pump is a 1.0 horse power, single phase, 115 Volt unit,
with a 2 -inch discharge and a built in diaphragm level control system or optional float system to regulate the
operation of the pump based on water levels in the tank. The existing pumps are not sized correctly and cannot be
reused. The pump operation and installation is simple, as the water level in the tank rises it switches on the pump,
which operates until it reaches the bottom of the pump and shuts the pump off. We can reused the operational float
level system for the tank. If it needs to be replaced, use a double float system, also by Hydromatic, Model 3900.
The pump is to set on the floor of the tank approximately 6 -inch above the floor. (Design details for operational
water levels in the tank are to be field determined by the design engineer. The type of pump control depends on
the dimensions of the tank). Please check to see if the existing tanks controls meet these recommendations, if they
do, they can be reused with the new system.
The pump operates at a approximately flow rate of 70 gallons per minute at the required 40 -feet head, and pumps
the effluent up to the manifold just prior to the distribution laterals. The manifold distributes the flow into the
laterals. The flow is evenly divided into the 8 lateral piping systems, (6 new and 2 existing). Additional
information on the selected pump is enclosed for your review and use.
At your option a second pump could be purchased as a backup or stand by pump. This would shorten the system
down time and inconveniences which will occur if the pump breaks down or has other problems. The cost of the
second pump is approximately 51,200.00. It is not required, but is recommended.
If not already installed, the effluent tank is also required by the County to be equipped with a high water level
alarm system to alert you when a pump has failed to operate or another problem has risen. The high water level
alarm system is operated by a float, mounted on the tank wall, which is activated when the water level rises to a
chosen point above the normal operating pump level. The float signals a red light and a buzzer, which should be
located in your adjacent mechanical room or garage. The buzzer can be turned off manually signaling
acknowledgment of the problem, but the red light stays on until after the water level drops back down. This is a
required safety feature which assists the owner in the satisfactory operation of system by letting you know you have
a problem before it becomes an emergency situation. The system we have chosen is a Tank Alert 1. by S.J. Electro.
(See design drawing for additional level control details. Please check to see if the existing alarm can be reused.
2 - 2 -inch PVC conduits from the adjacent home to the new effluent pumping tank can be reused. One is for power
to the pump and the other one for the high water level control system. Please inform the electrical designer of the
home of these additions.
Installation and Materials
The septic tank can be obtained from Copeland concrete products in Rifle, or from the locally in Emma from
Dreager. The tanks should be located as shown on the drawings and installed level. The access ports are to be
sealed water tight and brought up to within 6 -inches of final grade. If in the event the tanks are too high, minor
landscaping may be required to bury them. The invert elevations for both tanks are critical to the operation of tite
pump and should be followed closely. The blockouts for the inlets and outlets are also required to sealed water
tight to prevent infiltration.
All piping, pump, and alarm system materials can be obtained from Dodson Engineering products in Glenwood or
Grand Junction Pipe in Basalt. The 4 -inch piping from the house to the septic tank and to the pumping tank is
SDR 35. All manifold, distribution, and lateral piping is to be Schedule 40 PVC. All Piping should be installed at a
minimum depth of 3.5 -feet. The pumping line is to be laid with the shown slope to permit the line to drain back
into the tank after each pumping cycle to prevent freezing. The laterals are to be installed as shown on the
drawing and are need to be installed to within + or - .01 -feel. (See attached design drawing for bedding details and
additional installation notes.)
The septic system installation can be done by any excavation contractor who is familiar with this type of project. If
you have any questions on the design or other items, please feel free to call me at any time. See installation and
construction notes attached to this memorandum.
CC: CCA - MWE - Denver
PCEH - Nancy M.
Thanks, D �ier
to
+ EFOLUENT
OSP33 OSP33AB SPD50H & 100H
MAX. SOLIDS 5/8" SPHERE MAX. SOLIDS 5/8" SPHERE MAX. SOLIDS 3/4" SPHERE
1/3 HP 1/3 HP 1/2 AND 1 HP
1750 RPM 1750 RPM 3450 RPM
• Available in automatic or manual
• Non -clog bronze impeller
• No suction screens to clean
• Oil -filled, double ball bearing motor
with built-in overload protection
• Carbon/ceramic faced mechanical
shaft seal
• Great for septic tank effluent,
elevator pits, high capacity sump
service, industrial circulators
• Reliable diaphragm switch with
Piggyback plug-in
• Rugged cast iron construction
• Completely field serviceable
• 1-1/2" NPT discharge
• 1/3 HP, 1ta 115V or 230V
32
624
u
r iJ MP
216_-
a
0
0 10 zo ao 4o so
• Available in automatic
• All bronze construction
• Non -clog bronze impeller
• No suction screens to clean
• Oil -filled, double ball bearing motor
with built-in overload protection
• Carbon/ceramic faced mechanical
shaftseal
• Reliable diaphragm switch
• Completely field serviceable
• 1-1 /4" NPT discharge
• 1/3 HP, 10115V
• Available in manual or automatic
• Automatics feature reliable
diaphragm pressure switch (1 /2 HP),
wide-angle float switch (1 HP), both
with piggyback plug-in
• Dual shaft seals standard. Seal fail-
ure sensor capability available (wired
to alarm device) on manual pumps
• Non -clogging 2 -vane cast iron
sewage -type impeller
• Rugged cast iron construction
• 1/2 HP (SPD50H) and 1 HP
(SPD100H) motors. Ball bearing
construction and oil -filled
• 2" NPT discharge (3" flange opt.)
• 1/2 HP, 1 o 115V or 230V and 3o
200V, 460V or 575V — 1 HP, 1 o
230V and 200V, 3o 230V, 460V or
.F7rV
60 YO
2
4 _ w _...7 -i-
CAPACITY -U.S. GAM.
I
120 tp
ASPEN/PI10 ENVIRONMENTAL HEALTH DEPARTMO
ISDS DESIGN REQUIREMENTS -DEPARTMENT USE ONLY
Name SAMPLE DRAFT
House Size 3,000 (75 gpd, 100 gpd, or 130 gpd) 100
#of Bedrooms, Similar Rooms accessible to baths in Main Residence 4
# of Bedrooms, similar rooms w/ access to bath in ATTACHED caretaker
# of Bedrooms & Similar Rooms w/ access to baths in DETTACHED caretaker
Average Daily Waste Flow_ 600 # bedrooms X 2 people/br X 75
State Review Required? no
Perc Rate (T) 3 equals # of Perc Holes Required
Design Flo w (Q) = # bedrooms X 2 people/bedroom X gpd X 1.75
Q= 1400 1473.684
Minimum tank capacity 1750 gallons
Absorption Area (A= Q/5 X SQRT)
A = 0 sq. ft. of absorption area required
0 infiltrator units without reduction
A maximum 30% reduction is allowed for use of deep gravel or gravelless chambered system.
0 sq.ft. with reduction
0 infiltrator units with reduction
AREA NEEDED FOR STANDARD ABSORPTION TRENCHES
Q 0 Total sq ft /3 =lineal ft of trench needed
Q 0 lineal ft/assumed trench length of 60ft = # of 60ft trenches needed
1 # trenches minus 1 = rows of 6ft wide undisturbed soil between trenches
Q 0 times 3 = total width of of 60" long field needed for just the trenches
-1 times 6' = total width of 60' long field needed just for undisturbed soil
_6 width of trench +width of undisturbed soil = total width needed
-6 by 60 ft is the area needed for a standard absorption field in a trench configuration with no
reductions taken and ASSUMING AN AVERAGE PERCOLATION RATE OF 4
SLOWER PERCOLATING SOILS WOULD REQUIRE MORE AREA.
SETBACK FROM WELL SETBACK FROM POND, STREAM OR IRRIGATION DITCH
# of feet = 132 # of feet = 82
SETBACK FROM DRY GULCH
# of feet = 57
Remember: 8 feet of additional distance for each 100 gallons/day of design flow over 1,000 gallons/day
should be added unless an RPE can verify that it is not necessary to prevent contamination.
1/20/99
Printed on Recycled Paper
CN■■E
December 1, 1989
so
McLaughlin Water Engineers, Ltd.
210A Ventnor Ave., Aspen, Colorado 81611 (303) 925-1920
Pitkin County Environmental Health Department
Bob Nelson
130 South Galena
Aspen, Co. 81611
RE: WILTON SEPTIC SYSTEM DESIGN
Dear Bob:
As per our telephone communication last week, this letter is written to inform
you of the status of the proposed septic system on lot 4 of the Oh -Be -Joyful
subdivision owned by Clifton and Ann Wilton, McLaughlin Water Engineers, Ltd.
have been hired by the Wilton's to design the septic system for the proposed
residence on the lot. The design and the installation of the system will be
completed next spring. We do not have adequate percolation tests at the
location of the proposed system to complete the design at this time. These will
obtained next spring once the ground thaws. The system will be designed to
meet all Pitkin County Environmental Health requirements and will be submitted
to you for approval upon completion of the design and prior to installation.
The Wilton's and their representative Nancy Smith would like to proceed with
the required Pitkin County building application, which includes the septic system
permit this winter. I hope this letter assuring you that the system will be
designed by a professional engineer, meeting all Pitkin County requirements, will
allow the Wilton's to proceed with their building application without delays due
to the incomplete septic system design.
If you have any questions on this matter, please feel free to call me at any
time.
Vert Truly Yours,
MCLAUGHLIN WATER ENGINEERS, LTD.
Derosier, P,E.
CC: Nancy Smith
M WE -Denver
G D D/ PC EH LT R/89-020.01
RONALD C N'LAUGHUN
HAUORD E. UUCKBON
DOUGLAS T. SOVERN
WILLIAM C. TAGGART
ROBERT L. CARLEY
WILLIAM R. KENDALL
CHARLES L. HARDT
RALPH L. TOREN
IOHN T. WLANE
GINE A. BURRELL
MICHAEL E. MERCER
JOHN M. PRAIIM
MICHAEL R. GALUM
RONALD E. DVORAK
SCOTT E. LEHMAN
KENNETH D. ZIEBART
MART ANNE BASH
(ASTLE RU(K DENVER LAKE DILLON TULSA
13031 688 55N (303) 4565550 CKU) 468-2141 14181 664 2741
HAROLD ROBERTS
)AIX W SIEINMEYER
IEANDER L. URNfY
UMPLEfE tF(.IREI HItiO SERVICES IN WA]pR RIGHEB AND RFSODRdS 1MTFA TRFATMEN! AND DISfRIBMON SUBSURFACE DRAINAGE IRRIGATION IOLTTAINS SrOI1M DRAINAGE AND FLOOD C(MRROL
WASTEWATER COLLECTION. TREATMFM AND REUSE FEE PROTECTION WATER BASED RECREATION SPECIALTY HYDRALUCS KATE STUDIES AND MUTIES ECONOMICS
0
December 12, 1990
McLaughlin Water Engineers, Ltd.
210A Ventnor Ave., Aspen, Colorado 81611 (303) 925-1920
FAX (303) 925-1974
Pitkin County Environmental Health Department
Bob Nelson
RONALDC Mci UGHUN
HALPORD E ERICKSON
DOUGLAS T. SOVERN
W AM R KENDAL&
RAI L TOREN
TERRENCE P. KENYON
GEZA E KWM
130 South Galena GENE AR ER
LL CHAEL E MERCER
RCER
IOHN R. PFLAUM
Aspen, Co. 81811 6DCHAELR I
RONALD E DVORADVORAK
SCOTT E L AN
KENNETH D. ZIEBIEBART
RE:* HILTON SEPTIC SYSTEM; 89-M.01 MARYANNEBUSH
BRIAN S KOLSTAD
R JAMES MCLAUGHUN
G. DEAN DEROSIER
Dear Bob: RICHARD E MCIAUGHUN
HAROLD ROBERTS
LEANDER L URMY
On Wednesday December 5, 1990, I made a site visit to lot 4 of the Oh -Be -Joyful DANIEL M PETRAMAU
subdivision owned by Clifton and Ann Wilton, to inspect the recently completed
septic system installed on the property. The septic system was generally
installed according to the plans and specifications, by McLaughlin Water
Engineers, Ltd. On my site visit, I calculated the float elevations for the dosing
tank and the floats were installed by the contractor. The pump was connected
and ran as designed. The control system for tank levels and high water alarm
system operation was also verified during my visit. Attached is a copy of the
design drawing with corrections and dosing tank information for your files.
If you have any questions on this matter, please feel free to call me at any
time.
Vert Truly Yours,
McLAUGHLIN NATER ENGINEERS, LTD.
]( '
G'. DeanB-6—rosier, P.E.
CC: Nancy Smith/Cliff Wilton
MWE-Denver
G D D/ ecce pt a nce/89-020.01
DENVEK CO
(303) 45&5550
TUM& OK
(919) 6642741
moma(Az
(6D2)24IM02
LAKE DR N, CO
(303) 46&2141
COMPIETE ENGBJFPIUNG SFRVICE9IN
WATERRIGHTSAMIZESOURMIWATER TIffATMENT ANO DL4ZR1lU1fON SUKSIMACEDRAINAGE RIWGATRNV FOUNTAINS STORMDRAINAGEANDPIDODCONIROL
WASTEWATERCODECTIDRTREAWENTAND�E EWEPROTECTION WATERBASEO RECREATION SPECIALTYHYDRAW S RATESNpffS AND UTILIT65 ECONOAOCS
6 0
PITKIN COUNTY ENVIRONMENTAL HEALTH
Field Test Data Sheet on Percolation Test �! p�
Pkii n V
PROPERTY OWNER' �Ir' A�Je; W l� \6cv PHO Elf
MAILING ADDRESS
LEGAL DESCRIPTION OF PROPERTY
LOCATION OF TEST HOLES
Three (3) test holes required per system
�1
Test Hole Depths (24" minimum) _ pQ—
Diameter of Test Holes
LL—
k
Water remaining after 8 hour soak G
TEST HOLE No.t
TEST HOLE No. 2 TEST HOLE No. 3
Drop Time
Drop Time Drop Ti e
S'
Percolation Rate Each Hole
Average Rate W "
Comments on soil or site:
C)
l 8j1
Signature F
l �.
Q. lh ox,,,, - S (gr, 5
14 LO 1
Date
v
0
4
O
MN
0
U
L
REV. DATE
•1
01/19/00
PR -L DATE
O1/OS/00
SHEET
it �
D = f CONNECT TO EXIST. 2" MANIFOLD
EXTEND INTO NEW SYSTEM W/ 7 -7/2"
E - 2.5' f NEW ROWS OF 1" PERF PIPE LAY FILL OR
114" HOLE 0 60" OC, 071iER FILL ---EXISTING DISTRIBUTION PIPE
F - 0.75' 2 ROWS Of 2" PERF PIPE
77,
—f 1/4" HOLE ®3C," OC,
G f
H _ 1.5` / ,r iL i E I i I3 i t ':ti ii '; I ,TOP SOIL
PLOWED SURFACE
t
3/4" SCREENED ROCK
MOUND DETAILS MEDIUMSANDSAD FILL
CROSS SECTION — NTS
CONNECT TO EXIST SYSTEM EXTEND TO
NEW DEMENSIONS USING SIMILAR MATERIALS
W
A=24'
R
- 5o,
,L
— 72' 1
I1
IR..i2.5`
SYSTEM
+=
8
K >
1
c
/ - t
1 - 1,000 GALLON F Q
EXISTq,6 SEPTIC, T
�F
c -
ADD GALLON SEPTIC ANK —=
IN SERIES WITH EXISTING" 1,00 GALLO
ol
0
REUSE 1,000 GALLON
DOSING TANK
RO,AD-U,gY
LOCATION OF EXISTING
SEPTIC TANKS AND
FIELD IS APPROXIMATE
CLAY Of? OTHER FILL
MOUND DETAILS
PLAN VIEW
NEW SEPTIC FIELD
MOUND SYSTEM 45'-x 72'
EXTEND EXISTING=
/ NEW DISTRIBUTION IPINC"
TO SE 1" SGH 4 PERF 1/4" �a 60"
/ WELL To SYSTEM 124
t r s
,P -- J pL IPING
DIST11
PRF
'47 5C Q 3 / IS 2 5GH
1-c
�y� s�sfi"rG�p�i, 11 REUS6 E415TIT� 5.5STEM
W
�w
j
ROAD
DOSING TANK
NTS
DOSING TANK LEVELS
REUSE EXISTING DOSING TANK TO BY BE
REUSE
REPLACE PUMP WITH NEW SPD -100H
/CONTRACTOR TO VERIFY LOCATION
ELEVATION AND MATERIALS OF EX16TINGx
SYSTEM PRIOR TO INSTALLATION OF
0 NEW MOUND ADDITION
�0
Ia,s` CONTRACTOR TO EXPOSE EXISTING"
145 SYSTEM AND EXTEND TO NEW DEMENSIONS
\0
3 1
_ 3 1
CONNECT NEW I-I/2MANIFOLD TO
EXISTING; 2° MANIFOLD
5ECOND EXISITNG -LATERAL /?L
P
SEE DESIGN NOTES AND DETAILS FOR
ADDITIONAL INFORMATION
r.i
ORIGINAL DESIG=N rolSO - #8S-0020.0111
I [LIAM CAMFE3LL Af;R
S FTIC SYSTEM
��kariara,io�basiat+" FLAN AMD E)ETA IL
PROJECT NUMBER
AO-oo3.�Y
McLAUGHLIN WATER ENGINEERS, Ltd.
DESIGN 2420 ALCOTT ST. DENVER, CO 80211
DETAILIII vvvvvv������ 212
CHECK ff DATE 2 1 2 C��yy C DRAWING "I
�O NUMBER
016
NEW SYSTEM
EXISTING
SYSTEM
—
2" O!
TRI8U7 ON
DIS''RIBUTIGiv.
_
TE RAI.. NEN
ATERA
— EXIST
i
XI 712 cern
SLOPE
DOSING
7—17 2>•NE1 MAa•IFOLJ I EXI..
Mr".Td'rF0
TANK
f 1
t
BED 0r SLOPE
314" ROCK . x'
MOUND DETAILS
PLAN VIEW
NEW SEPTIC FIELD
MOUND SYSTEM 45'-x 72'
EXTEND EXISTING=
/ NEW DISTRIBUTION IPINC"
TO SE 1" SGH 4 PERF 1/4" �a 60"
/ WELL To SYSTEM 124
t r s
,P -- J pL IPING
DIST11
PRF
'47 5C Q 3 / IS 2 5GH
1-c
�y� s�sfi"rG�p�i, 11 REUS6 E415TIT� 5.5STEM
W
�w
j
ROAD
DOSING TANK
NTS
DOSING TANK LEVELS
REUSE EXISTING DOSING TANK TO BY BE
REUSE
REPLACE PUMP WITH NEW SPD -100H
/CONTRACTOR TO VERIFY LOCATION
ELEVATION AND MATERIALS OF EX16TINGx
SYSTEM PRIOR TO INSTALLATION OF
0 NEW MOUND ADDITION
�0
Ia,s` CONTRACTOR TO EXPOSE EXISTING"
145 SYSTEM AND EXTEND TO NEW DEMENSIONS
\0
3 1
_ 3 1
CONNECT NEW I-I/2MANIFOLD TO
EXISTING; 2° MANIFOLD
5ECOND EXISITNG -LATERAL /?L
P
SEE DESIGN NOTES AND DETAILS FOR
ADDITIONAL INFORMATION
r.i
ORIGINAL DESIG=N rolSO - #8S-0020.0111
I [LIAM CAMFE3LL Af;R
S FTIC SYSTEM
��kariara,io�basiat+" FLAN AMD E)ETA IL
PROJECT NUMBER
AO-oo3.�Y
McLAUGHLIN WATER ENGINEERS, Ltd.
DESIGN 2420 ALCOTT ST. DENVER, CO 80211
DETAILIII vvvvvv������ 212
CHECK ff DATE 2 1 2 C��yy C DRAWING "I
�O NUMBER
016