Permit
Application
Log Sheet/Notes & Photos
Communications.
As -built Design
Engineer Design
Soil Information
Water Permit & Information
Second System on property
Third System .etc.
Floor Plans
Please See Building and Land Use Approvals Files for additional information.
.ASP"'"PITKIN ENVIRONMENTAL HEALTH DEP
A
WENT
WON FOR INDIVIDUAL SEWAGt
APPLIDISPOSPWSTEM
130 S. Galena St., Aspen Colorado 81611
Phone 970-9205070/Fax 970-920-6039
Permit If r Sd a 0 / Parcel ID # a yG 7 - 3 y 3 - 0�1 _ o 5
Permit For. New Installation (v7 Repair ( ) Remodel () Emergency Use ( )
Name of OWNER ri 0r
�I
Owner's Mailing Address �7 % Q9,Qtg,.ty, - ()�• S h a c✓ivt rk; t(Eu � / 6 SSI
Business Phone: Home Phone: 9 7- 3. ?,J c%
Flame of Agent -
lgenl's Mailing Address
Business Phone: Cell Phone: Fax:
Copy of permit to be sent to: Owner( /A Agent ( ) Both ( )
Street Address
Legal Description: Lot 'I ,Block 61l� /iT T tZ 11 14 g .Subdivision
Size of lot: I acres Type of proposed structure: Res J cN e � Size of bldg. envelope:
Total arealliving space (sq. ft): bU # of Bedrooms, offices and similar size :rooms:
Water:( )Private well( )Spring ( )Stream ()Q Community/Public (Name of System) o S'
Is Proof of Adequate Water Attached? (J)Yes( ) No
Has this project been approved by Pitkin County ? (P Yes ( ) No
Is a copy of the floor plan attached ( required ) ? ( Yes ( ) No
Application for an intlintlual sewage dispos
at is hereby submitted. The undersigned acknowledges that the above information is We and that false information will
Invalidate the epprintlan end any subs. ent
k. Issuance of the permit does rot imply the approval of any other permit required for construction pursuant to Pitkin County
codes. No construction may be undena n u
I approval its have an obtained. The owner assumes all responsibilities n case of failure or Inadequacy of this
system,
Signature of applicant
-------------------------------------------------------------------------------------------------------------
q p
Date
vesrgn amen or system to oe mina I ttA Isjuba..�3.2 8 *
Septic tank capacity: J,� .�'Q gallons Absorption area: sq. ft.
Using -IIX Arca rtgda--I;ofs, 4 90`/o redteA&-N is allowed -fr pavelless c6AJers
ern abCd which is or 5d ehamberS . %h[_ design sPtei eairotS o� l♦,9{(
66n, "+� GAIsinwry musf 6e 4iloomd. 4H se+krecks mus+ he m4r'n+alrlcd .i bids mus+ b<_Ieve1. PPe I&Iffis ivttitsf be ver; }led roiJl. Jerre eny nee , so ilk is de_A%A In
A to,n;I liner shored 6e UMCI of AIL doarlhill aide Of file beds.
An inspection Is required prior to backfill of any component of the distrtbu0on system.
Design by Engineer Required? (,, Yes ( ) No All plans and specifications of the engineer must be followed. Any changes must be approved In
writing and the engineer must certify the final installation to the Environmental Health Department in wining.
EX fYn5J0') of Ori�r�CL�
Permit approval by: Date - 3/- 4 Rrr.u'} rtp prpJed .
Plans and specifications of the proposed 'ndividual ge dis arsm
I system have been reviewed and s nsldefed satisfactory. Petmissforl is hereby granted to the dimer or
me agent to prlor me work indicated in accrortlar with NePPftkin County ISDS Regulation n effect at aro time of Issue. This peril becomes invalid 6 months from the date
mal the peril was Issued unless system construction has mmnenced or an extension has been approved In wAng by the Department.
Installer.
As -Built drawings must be Included with this permit before the final approval will be Issued. (. o
Final Inspection Approval: Date: t{ /S- q(, ra�IDalerequested: 0/-/7-rf4
Date Pd.: Or- 15 -is Receipt : D a S/% Received by: rC Information complete:
No fee ncce5s" 4"sr'on
i G -F a
0 0
y- l7- 96 rn41 intfeA-o-) drru. o -j IzS6 5ePfi•c- -r loo y4rly,
PLLuOin^ kank.. k"els o IL ; in I t a oa.tlo4 P�fls o k-.
At illi Jv a /w-t.L ysfe, not bo o k -e- d yep • Feld .4 a - it
64&t�- thuS not i l5'Id.lrt4 ye .
b' -�6 Fn4kj I& of ` tC o[ jrdV ZfSS bejS (7-& w)45
in Cdr do 4. 16' of p,nd;54w6d wd kt44em 411,, beds. 1n5jX4-b'on
f70 In pIQGL. �iS4r;k4�0) box z :SCA 4/0 -6-116- d05inqJ4nL 1f
� - bax no 4- PIace � • tldaketj Cvr4rada- dlw, -H,iu cc
,y -+4 - box (f las-kc) leve l 91 UWK kilo j y ;8 kild
/D
&/./ &W 5 h' 1 t needs -Iv bC p l acrd o1 do c.-, k ll S"k of bo Nasc,
6cd • Cai6A*w will (d,(,l_ Lok" PUZr w d/&,j, SVS%K d+G in P)dce-
irr M5fcCfi•n • 7& &-ck, elv j jeer' w,ts 41 -so- dol,q AI,5
ln5PCA'01 • A// 5c4-bf 45 144.41 4;rw- d • J
kd Z f, f'f in&co'nexc4ions '1Yacc. d,15,, j -t.nlL
lox . viejs Ie/fes- tYvk G„y;,,CG,
l'n2( draw,'nq 6f 1ccord mj)wr recei*✓cd. S,yncd Co.
0
t Parc # �467-3y3- 0a=005
ASPENIPON ENVIRONMENTAL HEALTH DEPARTMIMT
APPLICATION FOR AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM QSDS) PERMIT
Name of OWNER k o h V\ M ✓14 P Q CA 1-_� Bus. Phone # ,?a 3� 4
Mailing Address J % — 7 V- Home Phone #
Name of AGENT IYI `)rti e.99 Bus. Phone #
Mailing Address 147 CfiZxinge [%r 5noaMjgss Co'11414Home Phone #
(a Dopy of Permit to be Sent to: I v a ✓
PERMIT IS FOR: � NEW INSTALLATION, () REPAIR () ALTERATION NOT DUE 1TO FAILURE, or () EMERGENCY USE. for permit #
STREET ADDRESS of Property: 140 J G Hie u/ � qd •Tool ro A S S Cv
LEGAL DESCRIPTION of Property: 66Te"'44 o 5n"m AISN. A lot � block _2,, filing _L_, and subdiv.
Size of Lot ) acres Type of Structure Proposed
# BEDROOMS ,, # LOFTS _, # GARBAGE DISPOSALS 1,, f DISHWASHERS L. #CLOTHES WASHERS I
Water Supply: O Private Well, O Spring, O Stream, or O System (Public or Private Name: 6'44e_wA
IS PROOF OF ADEQUATE WATER ATTACHED? (AYES or () NO HAS THIS PROJECT BEEN APPROVED BY PITKIN COUNTY? /YES or () NO
Appecadw lu an 1n .W aaenge dkpoad WY Par" k aalat Wrlbea. The aaaSabrMd aCbwMSE9ef Nd h abwa l'ApnrdiJn Y bus ane erat W. bbrindbrl raa IT.dWate 1he Pplkeem ab
any wbwe nt permit Issuance of the perms does sol esprct0y n tap/CYI1 bply M appwal of atry Mw* pe^ mg0ted Iv CarebuYion pursuant b Piton County codes. No corm may Ee uMerteken
rrrdil aE app s alto perml's lww been obWrwl TM onyr, Y asw"WA er in Car a fayuw or badepuacy of 0* system
SIGNATURE OF APPLICANTz< Date 5
The application becomes invalid 120 ays from the date s gned. This P is valid only for the design as specified below.
eevuuaaevaveaavameaaaay...BELOW FOR OFFICE USE ONLY. ... ............ ameauae
INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT # �$b,.2 O
$150 fee paid (a Yes. Date received S '6 - Q� Receipt # 00oZ 5 /(c Received By B K
DESIGN CRITERIA OF SYSTEM TO BE INSTALLED: Any changes must be submitted and approved M writing. '
liT>~ RCclrock - r)ew' —"rc 4a4 in ei is Hwr
# of Bedrooms: , Percolation Rate:_gjEa. mpi. Average Deily V�aste Flow: L n n gallons.
''/-
Is an Engineer Designed system needed? dyes or(I No WW.rw.row.csr suwasr«quw srwrarosorwa. Arrdwr,ga...r n. wpo+.d b..*n,ng .nd e+e e.re�ne«
shat eeday Uw ll W in lebw b dw Errv4orunentel 11eaM Depsrtnwry h rwlarq.)
Mi3lMurn Septic Tank Capacity_ gallons Absorption Area ya' square feel minimum k
( Absorption Bed, O Absorption Field In Trenches, O Oraw4lass system, ( umping/Dosing Chamber, O Absorption Pit
1E l� YO% rec(uc4i4r) i3 4010wed -fa-. 4/1.e gradelles5 e6tuu.b-r3 ;n abed or /9�5 �1 wi,-,A iva Jjd
be q% Q IJ5• _/ru lXAck dr5410 3jtCtAca*,'o7s 01 Cqh Co;nhq. En ;nre rnJr invsP be 411owed.
All Se4rayf(5 must bw- Fcan�a�.ud� Q,,d 4e- hed3 mYcsit do level 1�% �CngJhs acus be
Steges "u ring inspection: () Before nonvation, () Upon completion and prior to placement of gravel, (Be oro 6overing distribution system of absorption
field, 0 Prior to backfill of any component and any situation deemed necessary by Environmental Health Department Staff.
able " spac atlons of 0e propped bd ual sewage d4oal e,iMe Me ixen nr4wed aM an rdnidered W1 WCbry. Pemwsiion k he' -by granwd b IM owrrr p Ns &gem b Mdtlw �orM
eMk led &Cow M aceoedarce HM tM PIWn Count' bdrvtlual Sew&ge Dvpoel negulatbns b Med m pro ride d Isso. In addition b ganral pMibns ael tato N arty atlarlu,wn4, aur ParMl k wbjert
b aw fob"addN wrens and ouMMim, I arty:
APPROVED FOR ISSUE BY: DATE OF ISSUE: 6 - /5 --
The
-The above i, iv Iuel aawage dbposal aydem has been inspecwd 1#~ bY tW #11POW" Enyirm d NMW DepadnwK TM pMMr aavnws ay l"por"" "N ear d lallure or w.deeuacy d ma
Cy@ Compwe as Will drawing AW all sped(" ms of u4raa yaw bduded wM " pemiL
FINAL INSPECTION BY:
:0 f iADJMPC, Y PEPoAn.e.I
AN -Do 1I9a
DATE OF FINAL INSPECTION:
100 SOL" CiA ENA afRM - ASPEN, COLORADO Mill I • PMW g 1120MM • FAX 303MBIOT
PPPnED W RECYCLED PAPER
VO4''ed wi 4t-- 4tL en "neer , 50 � u.
1>u Ca acI ( ;s Ve_r �-Lj
S1wftJcl be u.szd anu clowAh;l1 s%dc d� Jt 6tds.
2
A 1Cr.,
Ven / Pitkin Environmental Health DepartmeTi'
Contact Log Sheet
Name:
103r4teigel-,
Parcel IN:
Address:
75AO�&0153 UJ54
Date
Person Spoken.
be Taken
Initials
Z
-
wMjI
-.
MY . .....
-,w-,
RESULTS LTS O F PERCOLATION TEST JOB
ADDRESS DESCRIPTION_�Q alA'}_r"'� _/�Up-_ DATE
DEPTH AND DIAMETER OF HOLE r1 N 3 _0 O -ZO -" 0 r2 � 3_ a O__/1Z 0 r3 - - - - O f.12_ ' 0
APPROX. GALS. ADDED HOLE #1 ^-_._ N2 r`-'-,%�- N3 ^
TEST HOLES WERE PRE-SOAKED FROM: (Dole)_/�_ZJ (Lme)TO: (Dale)A_z�Time) ________
HOLE # I ``HOLE #2 HOLE #3
TIME RjFO N?K FALL RAE TIME T� hMADRK FALL RAZE TIME RTO MARK FALL RAZE
4SA 3MNe 3 I Z 4 57 Z 3 AA
T534117
3o I 3Z lo3f l %¢ � o I z
3 3 .40
3 �L 40
3"p
PERCOLATION RATE:
REMARKS:
AREA SKETCH:
S_
9/94 F1 COUNTRY
MPI vv"
BY
INC. • 923 COOPER AVENUE GLENWOOD 8F
PROFILE HOLE
AND SOIL DESCRIPTION
1r1//11M'y-cr Zvp
Cv��/ 'b�ccrA�lPoSfY�
�RcTuT2rs'o
µlc, SLY
�rzF}c �urz�D
CO. SM • (303) 945-8678
ASPEN/PITKIN ENVIRONMENTAL HEALTH DEPARTMENT
ISDS DESIGN REQUIREMENTS
DEPARTMENT USE ONLY
Permit # 95020
Name Bruegger Parcel ID# 467-3y3- 0,2-00�r
House Size 2200 (75 gpd, 100 gpd, or 130 gpd) 100
Number of Bedrooms, Lofts, Offices, Similar Rooms, Main House 3
Number of Bedrooms, Lofts, Offices, Similar Rooms, Caretaker unit 0
Average Daily Waste Flow_
State Review Required? no
Perc Rate 40 (T)
675 # bedrooms X 2 people/br X 75 X 1.5
Design Flo w (Q) = # bedrooms X 2 people/bedroom X gpd X 1.75
Q= 1050
d10
Absorption Area (A= Q/5 X SQRT)
A = 1328.157 sq. ft. of absorption area required
74 infiltrator units without reduction
Aum 30% reduction is allowed for use of deep gravel or gravelless chambered system.
29.7096 sq.ft., with reduction---,,,, 3 rOrvS 6t /0
52 infiltrator units with reductio ( j
L ra�u� Or 1 / JJJ
Type of system: []Absorption trenches ffAbsorption bed [] Gravelless chambers
[]Dry well []Seepage Pit []Pumping Chamber
Is an Engineer -Designed System required? no _
yes ✓ reason
Minimum tank capacity
SETBACK FROM WELL
#o f feet = 104 NA
1250 gallons
slope_
Remember: 8 feet of additional distance for each 100 gallons/day of design flow over 1,000 gallons/day
should be added unless an RPE can verify that it is not necessary to prevent contamination.
APPROVED FOR ISSUE BY:
SYSTEM INSTALLED BY:
DATE OF FINAL INSPECTION REQUEST:
FINAL INSPECTION BY:
6Printed on Recycled Paper
DATE: 1- S/- e? 6,
DATE:
0 0
ASPEN/PITKIN ENVIRONMENTAL HEALTH DEPARTMENT
ISDS DESIGN REQUIREMENTS
DEPARTMENT USE ONLY
Name Bruegger
Permit # 95020
Parcel ID #
House Size 2200 (75 gpd, 100 gpd, or 130 gpd) 100
Number of Bedrooms, Lofts, Offices, Similar Rooms, Main House4
Number of Bedrooms, Lofts, Offices, Similar Rooms, Caretaker unit
Average Daily Waste Flow_ 900 # bedrooms X 2 people/br X 75 X 1.5
State Review Required? no
Perc Rate 40 (T)
Design Flo w (Q) _ # bedrooms X 2 people/bedroom X gpd X 1.75
Q= 1400
Absorption Area (A= Q/5 X SQRT)
A = 1770.875 sq. ft. of absorption area required
98 infiltrator units without reduction
A maximum 30% reduction is-atllowedd for use of deep gravel or gravelless chambered system.
01239.613 sq.ft. with reduction ---�.
69 infiltrator units with reductio
Type of system: []Absorption trenches []Absorption bed [] Gravelless chambers
[]Dry well []Seepage Pit []Pumping Chamber
Is an Engineer -Designed System required? no_
yes _ reason:
Minimum tank capacity 1750 gallons
SETBACK FROM WEA
# of feet =
Remember: 8 feet of additional distance for each 100 gallons/day of design flow over 1,000 gallons/day
should be added unless an RPE can verify that it is not necessary to prevent contamination.
APPROVED FOR ISSUE BY:
SYSTEM INSTALLED BY:
DATE OF FINAL INSPECTION REQUEST:
FINAL INSPECTION BY:
Printed on Recycled Paper
DATE:
DATE:
ASPEN/PITKIN ENVIRONMENTAL HEALTH DEPARTMENT
130 South Galena, Aspen CO 81611
(303) 920-5070
SOIL DATA FORM
PROPERTY ADDRESS JQ? Gaff w 24 ROA '�;rl,910 M 4SS'00
LEGAL DESCRIPTION La �i BIoCk F'ivtct ;n%rva� f� Sn/wrens: h7osns
PROPERTY OWNER:
ff77 J J
ADDRESS �r% EIk- h�NGr D� Snoiy.ky%sc Cv
PHONE 1 t%, 7 3 of `-i 9
Note:
* Percolation Test Result Form and Site Plan must be submitted
with this form.
* Percolation and profile holes should be located within a 1200
square foot'area'of the proposed septic system.
* For lots <5 acres the site plan must include the entire lot.
* Location of percolation and profile holes must be mapped
adequately and identified with. -stakes, flagging, etc.
Percolation holes must be identified.as.#1,#2, and #3.
ion and
• Smeared surfaces removed: _Yes _No
• Sand or gravel added: _Yes _No
Date and time presoak water added%
Amount of presoak water added (gallonS):
Date and Lime percolation test is started:
• Did water remain in hole after the overnight swelling
period:
Hole 1 _Yes _No
Hole 2 Yes _No
Hole 3 _Yes _No
Percolation Rate Measurement
Percolation Rate (min Jin.)
Hole 1
Hole 2
Hole 3
Average
Fncountered @ _feet.
Estimated depth to maximum seasonal
water table if not encountered in
profile:
Is area believed to be subject to seasonal
fluctuations which could result in a
seasonal water table within 8' of surface?
_Yes _No
(Slope determination in absorption area: _% to
the _(direction)
(Bedrock:
• Encountered @ _feu.
Estimated depth if not encountered in
profile:
Type of bedrock: _Sandstone
_Claystonc Siltstone
Is bedrock fractured or weadtcred?
Ycs No
Is bedrock believed to be permeable?
(Pert rate <60 min.ln.)
_Yes __No
Al
L-10
Certification
I certify that the above information is correct and complete to the
best of my knowledge and that all tests were performed in
accordance with the provisions of the Aspen/Pitkin Health
Department Sewage Regulations Title X by myself or under my
supervision. -
Original Signature Date
Phone
T
Original Seal
HEPWORTH-PAWLAIkEOTECHNICAL, INC. Road 154
Glenwood Springs, CO 81601
May I, 1995 945-11414
Phone 70945-7
Phone 970 945-7988
k
John Bruegger \5
47 Elk Range Drive
Snowmass, Colorado 81654 Job No. 195 168
Subject: Subsoil Study for Foundation Design, Proposed Residence, Lot 4, Block
2, Filing 1, Gateway to Snowmass, 407 Gateway Road, Pitkin County,
Colorado
Dear Mr. Bruegger.
As requested, Hepworth-Pawlak Geotechnical, Inc. performed a subsoil study for
design of foundations at the subject site. The study was conducted in accordance with
our agreement for geotechnical engineering services to you dated March 14, 1995. The
data obtained and our recommendations based on the proposed construction and
subsurface conditions encountered are presented in this report.
Proposed Construction: The proposed residence will be 2 stories with a lower garage
level located on the site as shown on Fig. 1. The floor and foundation levels will be
stepped to limit cut depth. Cut depths are expected to be up to about 10 feet.
Foundation loadings for this type of construction are assumed to be relatively light.
If building conditions or foundation loadings are significantly different from those
described above, we should be notified to reevaluate the recommendations presented in
this report.
Site Conditions: The site was vacant and relatively undisturbed at the time of our field
work. The ground surface is steeply sloping down to the east with between 20 and 25
feet of elevation difference across the building area. The building location and
topographic contours are shown on Fig. 1. Vegetation consists mainly of grass and
weeds with scattered juniper and pinon trees on the building site.
Subsurface Conditions: The subsurface conditions at the site were evaluated by
excavating two exploratory pits with a trackhoe on April 18, 1995 at the approximate
locations shown on Fig. 1. The logs of the pits are presented on Fig. 2. Access onto
the lot was attempted on March 24 and April 5, 1995 with a track mounted drill rig but
without success due to the steep road cut. Below about 1 1/2 feet of topsoil, weathered
claystone shale bedrock was encountered. The claystone shale was generally fractured
and jointed, and moderately hard to hard with depth. Results of Atterberg limits testing
performed on the claystone indicate a low plasticity. Some of the weathered claystone
shale bedrock in this area can have an expansion potential when wetted. Undisturbed
hand driven liner sampling of the claystone shale was attempted for laboratory
expansion tests but was not successful due to the hardness of the rock. No free water
10
John Bruegger
May 1, 1995
Page 2
was observed in the pits at the time of excavation and the materials were slightly moist.
The dip of the shale bedding appears to be moderately steep down to the east with
closely spaced joints and fractures.
Foundation Recommendations: Considering the subsoil conditions encountered in the
exploratory pits and the nature of the proposed construction, we recommend spread
footings placed on the undisturbed natural bedrock designed for an allowable bearing
pressure of 4,000 psf for support of the proposed residence. Due to the possible
expansion potential of the claystone shale bedrock, the footings should also be designed
to impose a minimum bearing pressure of 600 psf. The expansion potential of the
claystone should be evaluated at the time of excavation. Settlement should be minor but
some differential movement could occur due to post construction wetting. Overburden
soils and disturbed bedrock encountered at the foundation bearing level within the
excavation should be removed to expose the undisturbed rock. Footings should be a
minimum width of 12 inches for continuous walls and 18 inches feet for columns.
Exterior footings should be provided with adequate cover above their bearing elevations
for frost protection. Placement of footings at least 42 inches below the exterior grade is
typically used in this area. Continuous foundation walls should be reinforced top and
bottom to span local anomalies such as by assuming an unsupported length of at least 12
feet. Foundation walls acting as retaining structures should be designed to resist a
lateral earth pressure based on an equivalent fluid unit weight of at least 50 pcf for the
on-site soil and well broken rock as backfill. The backslope should be graded away
from the foundation a distance of at least one half the wall height but at least 5 feet.
Floor Slabs: The natural on-site soils, exclusive of topsoil, are suitable to support
lightly to moderately loaded slab -on -grade construction. There could be some floor slab
heave due to wetting of the claystone shale. To reduce the effects of some differential
movement, non-structural floor slabs should be separated from all bearing walls and
columns with expansion joints which allow unrestrained vertical movement. Slab
bearing partition walls may also need to have slip joints in the event of floor slab heave.
Floor slab control joints should be used to reduce damage due to shrinkage cracking.
The requirements for joint spacing and slab reinforcement should be established by the
designer based on experience and the intended slab use. A minimum 4 -inch layer of
free -draining gravel should be placed beneath basement level slabs to facilitate drainage.
This material should consist of minus 2 -inch aggregate with less than 50% passing the
No. 4 sieve and less than 2% passing the No. 200 sieve.
All fill materials for support of floor slabs should be compacted to at least 95 % of
maximum standard Proctor density at a moisture content near optimum. Required fill
should consist of imported granular soils such as road base.
H -P GEOTECH
John Bruegger
May 1, 1995
Page 3
Underdrain System: Although free water was not encountered during our exploration,
it has been our experience in mountainous areas and where bedrock is shallow that local
perched groundwater may develop during times of heavy precipitation or seasonal
runoff. Frozen ground during spring runoff can create a perched condition. We
recommend below grade construction, such as retaining walls, crawl space and
basement areas, be protected from wetting and hydrostatic pressure buildup by an
underdrain system.
The drains should consist of drainpipe placed in the bottom of the wall backfill
surrounded above the invert level with free -draining granular material. The drain
should be placed at each level of excavation and at least 1 foot below lowest adjacent
finish grade and sloped at a minimum 1 % to a suitable gravity outlet. Free -draining
granular material used in the underdrain system should contain less than 2% passing the
No. 200 sieve, less than 50% passing the No. 4 sieve and have a maximum size of
2 inches. The drain gravel backfill should be at least 2 feet deep.
Surface Drainage: The following drainage precautions should be observed during
construction and maintained at all times after the residence has been completed:
1) Inundation of the foundation excavations and underslab areas should be avoided
during construction.
2) Exterior backfill should be adjusted to near optimum moisture and compacted to
at least 95 % of the maximum standard Proctor density in pavement and slab
areas and to at least 90% of the maximum standard Proctor density in landscape
areas. Free -draining wall backfill should be capped with at least 2 feet of the
on-site, finer graded soils to reduce surface water infiltration.
3) The ground surface surrounding the exterior of the building should be sloped to
drain away from the foundation in all directions. We recommend a minimum
slope of 12 inches in the first 10 feet in unpaved areas and a minimum slope of
3 inches in the first 10 feet in pavement and walkway areas. A Swale will be
needed uphill to direct surface runoff around the residence.
4) Roof downspouts and drains should discharge well beyond the limits of all
backfill.
Site Grading: The risk of construction induced slope instability at the site appears low
with the proper grading and drainage design and construction. We understand that the
cut depths for the lower level will be up to about 10 feet. The shale is steeply dipping
H -P GEOTECH
is
John Bruegger
May 1, 1995
Page 4
which will be adverse to temporary cut stability on the uphill side. Fills should be
limited in depth at the uphill side of the residence on the existing steep slope.
Embankment fills for structural support should be compacted to at least 95 % of the
maximum standard Proctor density near optimum moisture content. Prior to fill
placement, the subgrade should be carefully prepared by removing all vegetation and
topsoil and compacting to 90% standard Proctor density. The fill should be benched
into the portions of the hillside exceeding 20% grade.
Permanent unretained cut and fill slopes should be graded at 2 horizontal to 1 vertical or
flatter. Cuts into competent shale of limited depth can probably be up to 1 to 1. The
risk of slope instability will be increased if seepage is encountered in cuts and flatter
slopes may be necessary. If seepage is encountered in permanent cuts, an investigation
should be conducted to determine if the seepage will adversely affect the cut stability.
This office should review site grading plans for the project prior to construction and
observe cuts for stability considerations.
Percolation Testing: Percolation test holes were excavated in the southern part of the
lot for septic disposal. The excavations encountered claystone shale bedrock at depths
less than 3 feet below the existing ground surface. In addition the terrain is steep and
irregular. An engineered septic system will be required and should be designed by a
civil engineer with attention given to the shallow bedrock conditions and the steep
downslope.
Limitations: This report has been prepared in accordance with generally accepted
geotechnical engineering principles and practices in this area at this time. We make no
other warranty either expressed or implied. The conclusions and recommendations
submitted in this report are based upon the data obtained from the exploratory pits
excavated at the locations indicated on Fig. 1, the proposed type of construction and our
experience in the area. Our findings include interpolation and extrapolation of the
subsurface conditions identified at the exploratory pits and variations in the subsurface
conditions may not become evident until excavation is performed. If conditions
encountered during construction appear different from those described in this report, we
should be notified at once so re-evaluation of the recommendations may be made.
This report has been prepared for the exclusive use by our client for design purposes.
We are not responsible for technical interpretations by others of our information. As
the project evolves, we should provide continued consultation and field services during
construction to review and monitor the implementation of our recommendations, and to
verify that the recommendations have been appropriately interpreted. Significant design
changes may require additional analysis or modifications to the recommendations
presented herein. We recommend on-site observation of excavations and foundation
H -P GEOTECH
13
John Bruegger
May 1, 1995
Page 5
presented herein. We recommend on-site observation of excavations and foundation
bearing strata and testing of structural fill by a representative of the soil engineer.
If you have any questions or if we may be of further assistance, please call our office.
Sincerely,
HEPWORTH - PAWLAK GEOTECHNICAL, INC.
Jr, P
Reviewed By:
�i7._ _ae'7 �
Steven L. Pawlak, P.E.
JZA/rr
�.N
? V 2S T -y _
pc 4'
...........
O�A
Attachments
cc: Pattillo Associates - Attn: Jim Romeo
H -P GEOTECH
11
APPRDXIMATE SCALE
I = 40'
LOT 3
LOT 4
\ Ip
744),
i
I
LOT 5
\
\ \IM
(BOUN�DARI�ES
OSED
rwRESIDENCE
F�4r
\
� t•
Ro4p \
\ 10
100
9�
HEPWORTH-PAWLAK I Fig.
195 168 GEOTECHNICAL Inc. LOCATION OF EXPLORATORY PITS I
�J
1 Ca
10
Pit 2
Elev.=108'
LL=26
PI=8
LEGEND:
TOPSOIL; silty clay; organic, roots, firm, slightly moist to moist, grayish
brown.
WEATHERED CLAYSTONE/SHALE BEDROCK; moderately hard, fractured,
oxidation staining, slightly moist, grayish brown and gray.
CLAYSTONE SHALE BEDROCK; moderately hard to very hard, slightly
moist, closely spaced joints in shale, gray.
h2 -inch Diameter Hand Driven Liner.
Disturbed Bulk Sample.
NOTES:
1. Exploratory pits were excavated on April 18, 1995 with a Cat 931 trackhoe.
2. Locations of exploratory pits were measured approximately by pacing from features shown
on the site plan provided:
3. Elevations of exploratory pits were obtained by interpolation between contours on the site
plan provided.
4. The exploratory pit locations and elevations should be considered accurate only to the
degree implied by the method used.
5. The lines between materials shown on the exploratory pit logs represent the approximate
boundaries between material types and transitions may be gradual.
6. No free water was encountered in the pits at the time of excavating. Fluctuations in water
level may occur with time. '
7. Laboratory Testing Results:
LL = Liquid Limit M
PI = Plasticity Index I%)
1195 168 I GEOTECHMHEPORTH-PAW In
195 LOGS OF EXPLORATORY PITS I Fig. 2
GATEWAY TO SNOWMASS MESA SUBDIVISION
PROPERTY OWNERS ASSOCIATION, INC.
May 8, 1995
To Whom It May Concern,
John Bruegger is entiltled to water service and one water tap for his proposed house located in
the Gateway to Snowmass Mesa Subdivision located at Filing 1, Block 2, Lot 4.
Please give me a call with any questions.
Sincerely,
Joe Raczak
970-925-1510
970-927-4800
EI
MAY 22 '1995
t;-
14 P.O. BOX 21! 5H0\dPAA5 S,C0A',()RAD0 8165d
w
)
/
„
--
D•
i
2
x
i
Cliff
-r.
7. VlS.7l.(.C11e P- s' widvek�'(i easerv�er��, i�n.s�e cell lo�% lubes.
EXCEPTION 12 (ASPEN TIT CORP. ORDER NO. 403060-C3) DOES NOT AFFECT
THE LOTS DEPICTED AB
i.
i
�jlereby certify
si i6ncrete found,
Ch�
t rephic„
:2 a r
•
zreby certify that on November 29, 1995 I surveyed the location and elevation of
increte foundation as shown hereon to the best of my knowledge and belief. However,
stTP°�raphic fOraation as shown hereon has not been altered to reflect construction
stiyr re,(\�l ley In?��iO P
11// �pnn ra hic conditions as of ,lune 73, 1990,
1 "'-*-M3.. 5. 14111
j;
v reS'Mv- E C -QP 1Ma.v-ked
j9
To� nuc ky C.vCiylt
L.S. �"4tj
Legal Description:
Lots 3 and 4, Block 2, Gateway of Snowmass Mesa Subdivision, Filing No. 1,
Pitkin County, Colorado.
ko Sa 135'QkvAw%CLML 3QevocZLble TYUst
I hereby certifyhhat on June 13, 1990 a survey was performed by me on the above
described parcel of land. All easements, encroachments and rights-of-way in
evidence or known to me Rr^ shown. This survey is true and correct to the best
of my knowledge and pelir'.
By:......—
I
y to come . .
0
n
U
93
goo
180 170
ISO
140 ;sib
%�
oaS
110
r
L
C2/s/9lo
J
VVVe
/ ) / / (lel/
IN"
O
a ,ry
OPO ry ry ryoo °o
S 90'00'00" E
�..-.._..._. -..-. _ _-.._..-..-.._..
332.8 -..-.. 0'
3(5' SETBACK `
�^ QD -OO TO BUILDING
22120 /
118 N'
116
`y ' �CJ 1.14
�ACV
\ \\ q
pQ, ` ` 1 ; 2
110
\ 1 108 "
%K. , ¢ A 'Its,
1004.
:
GRAPHIC SCALE
0 w 20 40
( IN FEET )
I inch = 20 ft
30SETBACK /
70 BUILDING
QT 1250 GAL,PRECAST /
CONCRETE SEPTIC TANK .
L1000 GAL: PRECAST %
N C SPe� DOSING, TANK /
\ 60� • \ \ Ow '• /
?Ss\ SO e Q
•9S%
\ , Qp �IP
D-17 T
f..
701 \ i
REM OV E GAP ,
w
CUT HOLE IN TOP OF INFILTRATOR UNIT
FOR INSTALLATION OF INSPECTION WELL
SOLID PIPE J ! —PIPE
COUPLING
PERFORATED PIPE
INSPECTION WELL DETAIL
BED CROSS SECTION (TYE.)
N 1' S.
4" X 4'—+
TREATED —ELEC JCT. BOX
POST
RISER(S) TO
GROUND SURFACE—
CAULK/SEAL WELL a`
INLET
a
Z
"ALARM
"ON" —
2v WEIGHT
ae
VICINITY MAP
SECTION 34, T.8 S., R.86 W., 6th P.N.
WOODY CREEK QUADRANGLE
SCALE 1"=2000'
SENFRAL ABSORPTION TRENCH NOTES
1. TRENCH LENGTH SHALL NOT EXCEED 100 FEET.
2 THE BOTTOM OF EACH TRENCH SHALL BE LEVEL.
3 DRAINAGE DITCHES ARE TO BE PROVIDED ABOVE AND ARJUND
TRENCHES, AS NECESSARY, TO PREVENT SJRFAa RUNOFF FROM
ENTERING ABSORPTION AREA.
4. TRENCHES SHALL FOLLOW CONTOURS.
"OFF"
10 O O
e e
2" AIR VENT
2" FEEDER LINE TO DISTRIBUTION
BOX OR SLOPED AT
1/8" PER FT. MIN.
OJICK DISCONNEC
OR UNION
COIL AND TIE AN
ADDITIONAL 10' OF
WIRE FOR PUMP
REMOVAL
SUBMERSIBLE WASTEWATER PUMP
SET MOTOR APPROX.
8" OFF FLOOR
/ NOTES:
1. SWITCHES TO BE MERCURY FLOAT TYPE,
2. FLOAT SWITCH DIMENSIONS ARE BASED ON A COPELAND 1000 GAL. TANK.
(CISTERNI
3. DOSING TANK SHALL BE OF WATERTIGHT CONSTRUCTION.
4 ALARM SHALL BE BOTH AUDIBLE AND VISIBLE. LOCATED WITHIN
THE HOUSE AND ON A CIRCUIT SEPARATE FROM THE PUMP.
5. PUMP SHALL BE CAPABLE OF AT LEAST 20 GPM O 45 FT OF HEAD.
'K (ELEVATION DIFFERENCE AND PIPE LENGTHS SHALL BE FIELD MEASURED BY
C�ACTOR AND REFERRED TO ENGINEER FOR VERIFICATION OF PUMP PARAMETERS)
DOSING TANK ARRANGEMENT -
N. T -S.
C
*FIELD SIZE: PER PITKIN CCNJNTY EQUATIONS
A ' !4-5Q _ 0. G".•5 O - MAX I MUFi{ L',)W
A = _ 1170 — 0.0551.600)-
0.4
PER CDOH MINIMUM REQUIREMENTS FOR USE OF "INFILTRATOR' SYSTEMS
IN BED, AREA REDUCTION — (0.4).A
AREA. REQUIRED = 2892 SF��1735 SO. FT,
�.�
O 18 SO. FT. PER UNIT 96 UNITS
3, TOPSOIL: SOIL EXCAVATED FROM SITE ACCEPTABLE IF NO CLAY IS
PRESENT.
4. VEHICULAR TRAFFIC IS PROHIBITED ON THE FIELD.
5. CLEANOUTS ARE REQUIRED AT ALL BENDS AND AT LEAST EVERY 100
FEET ALONG THE HOUSE SEWER.
6. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS TO
WITHIN 1/2 -FOOT OF FINAL GRACE.
7. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG
AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED.
8. PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM
ABSORPTION AREA USING DRAINAGE SWALES AS NECESSARY.
S. PERCOLATION RATE BASED ON REPORT BY HIGH COUNTRY ENGINEERING
DATED MAY 5, 1995,
10. THIS DRAWING DOES NOT CONSTITUTE AN ISDS PERMIT. PERMIT MUST
BE DETAINED FROM APPROPRIATE CITY OR COUNTY OFFICIALS.
11. THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH OR
FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS OR
FILTERS SHOULD NOI BE INTRODUCED INTO THIS SYSTEM.
-
8/9!95 j UPDATE FOR PERC TEST JF
'��i� �P• , ,. ��a� N0. DAT REVISION I BY
N Inti*�U� SMITH-BRUEGGER CONSTRUCTION, INC.
-> PITKIN COUNTY, COLORADO
OUNTR"
NG/n'lERNvG y--- INDIVIDUAL SEWAGE DISPOSAL SYSTEM
GATEWAY OF SNOWMASS MESA SUBDMSION
LOT 4, BLOCK 2, FILING #1
HW COUNTRY ENOMERINC,4 NC. _
923 COOPER AVENUE — — _
QLENm CO , CO 81601 DES. TPB CK. FILE N0 FSHEET1
OhBRJ ( )�5-8676 DR JF DATE 5/1/95 9J5004.06 1
GENERAL NOTES
ALL CONSTRUCTION SHALL BE IN ACCORDANCE
WITH THE
11U�1
57
A
2.
FITKIN COUNTY REGULATIONS OF INDIVIDUAL
SYSTEMS. EVEN THOUGH ALL SUCH REOUIREMENTS
SPECIFICALLY NOTED ON THE DRAWINGS. THE
RESPONSIBLE FOR SUCH SPECIFIC DETAILS AS
THE ABOVE-MENTIONED REGULATIONS
FLOW: 4 BEDROOMS +2 PERSONS/BEDROOM .75
600 GPO= AVERAGE DAILY FLOW
DESIGN = 1.955• AVERAGE - 117C GPD (FOR A
SEWAGE DISPOSAL
ARE NOT
CONTRACTOR SHALL BE
ARE REFERRED TO IN
GALLONS/PERSON/GAY IS
BED SYSTEM)
SEPTIC TANK: MINIMUM TANk SIZE IS 1250
GALLONS.
SENFRAL ABSORPTION TRENCH NOTES
1. TRENCH LENGTH SHALL NOT EXCEED 100 FEET.
2 THE BOTTOM OF EACH TRENCH SHALL BE LEVEL.
3 DRAINAGE DITCHES ARE TO BE PROVIDED ABOVE AND ARJUND
TRENCHES, AS NECESSARY, TO PREVENT SJRFAa RUNOFF FROM
ENTERING ABSORPTION AREA.
4. TRENCHES SHALL FOLLOW CONTOURS.
"OFF"
10 O O
e e
2" AIR VENT
2" FEEDER LINE TO DISTRIBUTION
BOX OR SLOPED AT
1/8" PER FT. MIN.
OJICK DISCONNEC
OR UNION
COIL AND TIE AN
ADDITIONAL 10' OF
WIRE FOR PUMP
REMOVAL
SUBMERSIBLE WASTEWATER PUMP
SET MOTOR APPROX.
8" OFF FLOOR
/ NOTES:
1. SWITCHES TO BE MERCURY FLOAT TYPE,
2. FLOAT SWITCH DIMENSIONS ARE BASED ON A COPELAND 1000 GAL. TANK.
(CISTERNI
3. DOSING TANK SHALL BE OF WATERTIGHT CONSTRUCTION.
4 ALARM SHALL BE BOTH AUDIBLE AND VISIBLE. LOCATED WITHIN
THE HOUSE AND ON A CIRCUIT SEPARATE FROM THE PUMP.
5. PUMP SHALL BE CAPABLE OF AT LEAST 20 GPM O 45 FT OF HEAD.
'K (ELEVATION DIFFERENCE AND PIPE LENGTHS SHALL BE FIELD MEASURED BY
C�ACTOR AND REFERRED TO ENGINEER FOR VERIFICATION OF PUMP PARAMETERS)
DOSING TANK ARRANGEMENT -
N. T -S.
C
*FIELD SIZE: PER PITKIN CCNJNTY EQUATIONS
A ' !4-5Q _ 0. G".•5 O - MAX I MUFi{ L',)W
A = _ 1170 — 0.0551.600)-
0.4
PER CDOH MINIMUM REQUIREMENTS FOR USE OF "INFILTRATOR' SYSTEMS
IN BED, AREA REDUCTION — (0.4).A
AREA. REQUIRED = 2892 SF��1735 SO. FT,
�.�
O 18 SO. FT. PER UNIT 96 UNITS
3, TOPSOIL: SOIL EXCAVATED FROM SITE ACCEPTABLE IF NO CLAY IS
PRESENT.
4. VEHICULAR TRAFFIC IS PROHIBITED ON THE FIELD.
5. CLEANOUTS ARE REQUIRED AT ALL BENDS AND AT LEAST EVERY 100
FEET ALONG THE HOUSE SEWER.
6. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS TO
WITHIN 1/2 -FOOT OF FINAL GRACE.
7. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG
AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED.
8. PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM
ABSORPTION AREA USING DRAINAGE SWALES AS NECESSARY.
S. PERCOLATION RATE BASED ON REPORT BY HIGH COUNTRY ENGINEERING
DATED MAY 5, 1995,
10. THIS DRAWING DOES NOT CONSTITUTE AN ISDS PERMIT. PERMIT MUST
BE DETAINED FROM APPROPRIATE CITY OR COUNTY OFFICIALS.
11. THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH OR
FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS OR
FILTERS SHOULD NOI BE INTRODUCED INTO THIS SYSTEM.
-
8/9!95 j UPDATE FOR PERC TEST JF
'��i� �P• , ,. ��a� N0. DAT REVISION I BY
N Inti*�U� SMITH-BRUEGGER CONSTRUCTION, INC.
-> PITKIN COUNTY, COLORADO
OUNTR"
NG/n'lERNvG y--- INDIVIDUAL SEWAGE DISPOSAL SYSTEM
GATEWAY OF SNOWMASS MESA SUBDMSION
LOT 4, BLOCK 2, FILING #1
HW COUNTRY ENOMERINC,4 NC. _
923 COOPER AVENUE — — _
QLENm CO , CO 81601 DES. TPB CK. FILE N0 FSHEET1
OhBRJ ( )�5-8676 DR JF DATE 5/1/95 9J5004.06 1
/
L V I 1/
�ryp o o LOOP ROWS OF UNTIS
Q OGETHER (TYP.)
DISTRIBUTION BOX
/ X /
/ o S 90'00'00_E_.._.._.._.._.._.._..
...... ...... ......
_.._.._.._.._.._.._.._.._.._.._..
332.80' `
—130 1
� / • / O.
a" PVC o 122 120 0�
/ tij�•' ' INSPECTION16 WELL / ' / / ._ .. 114
112 v.
� _110 /.
/ Oh/ 40 PVC �� cF 108 AD)/.
00.
100 /
EAA OUT /
/
SEE JgL�OW-UP THIS SHEET
O - OR/AS-BUILT DIMENSIONS
IV XVSs / O /�6/ S
0ETE�EPTICTANK
bO .
�\
d /
L 0 T 9J e \ \ / / OOS NG9TANK PRECAST
/ 1 j
`gay, 0� CLEANOUT
(o
/ 01
0
dor
/
/I
0
1250 GAL. VRECAST
CONCRETE SEPTIC TANK
1000 GAJc.' PRECAST
`DOSING- TANK
AS -BUILT BLOW-UP
SCALE: 1"=10'
PLACE 10 MIL PVC -,,.-
LINER ON DOWNHILL
SIDE OF TRENCH
NATURAL BACKFILL
BED CROSS SECTION (TYP.)
N.T S
O
r°tie�� TO �.•\ - / P� GRAPHIC SCALE
20 0 10 20 40
1 I I I I
TRATOR UNIT
/
4" X 4' -
TREATED
POST
INLET
I
REMOVABLE CAP
CUT HOLE IN TOP OF INFILTRATOR UNIT
FOR INSTALLATION OF INSPECTION WELL
PIPE
COUPLING
PERFORATED PIPE
INSPECTION WELL DETAIL
N.T.S.
ELEC. JCT. BOX
RISER(S) TO
GROUND SURFACE
-CAULK/SEAL WELL
Z
f
"ALARM"
"ON"
N WEIGHT
"OFF"
a
00
NOTES
( IN FEET )
1 inch = 20 ft.
GENERAL ABSORPTION TRENCH NOTES
1. TRENCH LENGTH SHALL NOT EXCEED 100 FEET.
2. THE BOTTOM OF EACH TRENCH SHALL BE LEVEL.
3. DRAINAGE DITCHES ARE TO BE PROVIDED ABOVE AND AROUND
TRENCHES, AS NECESSARY, TO PREVENT SURFACE RUNOFF FROM
ENTERING ABSORPTION AREA.
4. TRENCHES SHALL FOLLOW CONTOURS.
F m
2" AIR VENT
2" FEEDER LINE TO
FIELD, SLOPED AT
1/8' PER FT. MIN.
SHALL DRAIN BACK
TO TANK AFTER
EACH PUMP CYCLE.
QUICK DISCONNECT
OR UNION
COIL AND TIE AN
ADDITIONAL 10' OF
WIRE FOR PUMP
REMOVAL
SUBMERSIBLE WASTEWATER PUMP
SET PUMP APPROX.
8" OFF FLOOR
1. SWITCHES TO BE MERCURY FLOAT TYPE.
2. FLOAT SWITCH DIMENSIONS ARE BASED ON A COPELAND 1000 GAL. TANK.
(CISTERN)
3. DOSING TANK SHALL BE OF WATERTIGHT CONSTRUCTION.
4. ALARM SHALL BE BOTH AUDIBLE AND VISIBLE, LOCATED WITHIN
THE HOUSE AND ON A CIRCUIT SEPARATE FROM THE PUMP.
5. PUMP SHALL BE CAPABLE OF AT LEAST 20 GPM 0 45 FT. OF HEAD.
(ELEVATION DIFFERENCE AND PIPE LENGTHS SHALL BE FIELD MEASURED BY
CONTRACTOR AND REFERRED TO ENGINEER FOR VERIFICATION OF PUMP PARAMETERS.)
DOSING TANK ARRANGEMENT
N T. S.
�` ''�
`\"_ 1pou In TtiR -
-
1./A_ - -•- -#\ 1•rYE
RAJ
]
26"
REVD. PER HOUSE SIZE AND COUNTY REGS.
1
v "y�il1
(^
��`�
6/9/95
I,c
JF
NO.
DATE
I REVISION
--'r -
III �) I�•I''1
r..�\? /S 1
r,_.
_(q
1'�,li//���.)O
r)
�� �''I ''I �
r.
sowv=
�' lC
33
> ITYy
I
I ,
80
VICINITY MAP
SECTION 34, T.8 S., R.86 W., 6th P.M.
WOODY CREEK QUADRANGLE
SCALE: 1"=2000'
GENERAL NOTES
1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE
PITKIN COUNTY REGULATIONS OF INDIVIDUAL SEWAGE DISPOSAL
SYSTEMS, EVEN THOUGH ALL SUCH REQUIREMENTS ARE NOT
SPECIFICALLY NOTED ON THE DRAWINGS. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN
THE ABOVE-MENTIONED REGULATIONS.
2. FLOW: 3 BEDROOMS *2 PERSONS/BEDROOM *100 GALLONS/PERSON/DAY IS
600 GPD = AVERAGE DAILY FLOW.
DESIGN = 1.75* AVERAGE = 1050 GPD (FOR A BED SYSTEM)
SEPTIC TANK: MINIMUM TANK SIZE IS 1250 GALLONS
*FIELD SIZE: PER PITKIN COUNTY EQUATIONS:
A = DESIGN FLOW
A - Q X Nft 0 - MAXIMUM FLO`:V A = 1050 , \140
5 t = PERC RATE 5
PER COUNTY REQUIREMENTS FOR USE OF "INFILTRATOR" SYSTEMS
IN BED, AREA REDUCTION = (0.7)*A
AREA REQUIRED = 1328 S.F. - 30% = 930 SQ.FT.
0 18 SQ. FT. PER UNIT = 52 UNITS
3. TOPSOIL: SOIL EXCAVATED FROM SITE ACCEPTABLE IF NO CLAY IS
PRESENT.
4. VEHICULAR TRAFFIC IS PROHIBITED ON THE FIELD.
5. CLEANOUTS ARE REQUIRED AT ALL BENDS AND AT LEAST EVERY 100
FEET ALONG THE HOUSE SEWER.
6. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS TO
WITHIN 1/2 -FOOT OF FINAL GRADE.
7. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONC
AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED.
8. PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM
ABSORPTION AREA USING DRAINAGE SWALES AS NECESSARY.
9. PERCOLATION RATE OF 40 MPI BASED ON REPORT BY HIGH COUNTRY
ENGINEERING DATED MAY 5, 1995.
10. THIS DRAWING DOES NOT CONSTITUTE AN ISDS PERMIT. PERMIT MUST
BE OBTAINED FROM APPROPRIATE CITY OR COUNTY OFFICIALS.
11. THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH OR
FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS OR
FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM.
D
MAY 15 1997
ENVIRONMENTAL HEALTH
ASPEN / PITKIN
RECORD DRAWING
4/16/97
SWING TIES AND NUMBERS IN PARENTHESIS
INDICATE FIELD MEASUREMENT.)
THIS RECORD DRAWING HAS BEEN PREPARED BASED ON INFORMATION
SUBMITTED, IN PART, BY OTHERS. WHILE THIS INFORMATION IS BELIEVED
TO BE RELIABLE, THE ENGINEER IS NOT RESPONSIBLE FOR ITS ACCURACY,
NOR FOR ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO
THIS DOCUMENT AS A RESULT.
3
4/16/97
1 RECORD DRAWING
RAJ
2
2/13/96
REVD. PER HOUSE SIZE AND COUNTY REGS.
JF
1
6/9/95
UPDATE FOR PERC TEST
JF
NO.
DATE
I REVISION
BY
SMITH-BRUEGGER CONSTRUCTION, INC.
PITKIN COUNTY, COLORADO
INDIVIDUAL SEWAGE DISPOSAL SYSTEM
GATEWAY OF SNOWMASS MESA SUBDIVISION
LOT 4, BLOCK 2, FILING #1
HIGH COUNTRY ENGINEERING, INC.
923 COOPER AVENUE
GLENWOOD SPRINGS, CO 81601 DES. TPB CK. FILE NO. SHEET 1
O6BRU () 945-8676 DR. JF DATE 5/1 /95 95004.06 OF 1