Loading...
HomeMy WebLinkAboutpitkin.eh.247114301013 (2014)Document Layout (From Most Recent to Oldest Permit) Permit Application Log Sheet/Notes & Photos Communications As -built Design Engineer Design Soil Information Water Permit & Information Second System on property Third System .etc. Floor Plans Please See Building and Land Use Approvals Files for additional information. NR Permit* 0011.2014.powt SITE WASTEWATER TREAT&T SYSTEM (OWTS) CONSTRUCTION PERMIT 76 Service Center Rd Aspen, CO 81611 Phone: 970.920.5070 Fax: 970.920.5374 Parcel ID #: 2471-143-01-013 Permit Issued: ®NEW CDU []REPAIR ❑REMODEL/ADDITION []TANK ONLY []FIELD ONLY []AMENDMENT Owner(s): Randy and Kara Schumacher Property Address: 210 Miller Creek Trail Legal Description: Size of Lot: 12.477 Acres Detached Accessory Unit: OYES ONO Size of Building: 3483 Sq. Ft. Size of Accessory Unit: Sq Ft s Designed By: HP Geotech Project #: 113129A Dated: June 28, 2013 Phone #: 970-945-7988 Mailing Address: 5020 CR 154 Glenwood Springs CO Fax #: Email Address: Perc Rate: 45 mpi Profile Hole Depth: 7.5 It Depth to Groundwater or Bedrock: >7.5 It Minimum Tank Capacity: 844 gallons Minimum Absorption Area: 887 If (30 % Reduction) Permit Conditions: This OWTS Construction Permit is approved on the condition of compliance with the engineer design as submitted with the application and the specifications cited above. Changes must be approved by this Department and the engineer prior to construction. This permit is for the installation of a new septic system for a 3 bedroom residence. The design identifies two of the bedrooms as bunkrooms. However, the system has been oversized by Pitkin County Regulations and is adequate for 5 bedrooms/10 persons. Sewage will flow via gravity to a 1,500 gallon two -chamber concrete septic tank with an effluent filter installed in the second compartment. Effluent will flow via gravity to a 7 -trench, serial -distribution soil treatment area. Each trench will have 22 Quick - 4 chambers for a total of 154 chambers. Inspection ports will be installed at the end and beginning of each trench. The soil treatment area shall be a minimum of 100 feet to any well and 50 feet to any stream or pond and 25 feet to any dry gulch. This Permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an "as -built' letter to this Department within 30 days of the final inspection, unless a longer period of time has been agreed upon, in writing. This Department must also be called for the final inspection with a minimum of 48 hours notice. Minimum horizontal distances between components of the system and physical features shall conform to the requirements of the Pitkin County OWTS Regulation. This Permit is conditioned upon the property owner(s) providing for regular inspection, cleaning, and maintenance of the system by qualified personnel, in accordance with the manufacturer's recommendations and the requirements of the Pitkin County OWTS Regulation. Issuance of this OWTS Construction Permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail. Issuance of this permit does not imply compliance with Pitkin County building and/or land use regulations, nor guarantee issuance of building and/or land use permits. THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN COUNTY OWTS REGULATION, INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE. Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Pitkin County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built' drawing must be submitted and approved by EH before final approval of the system will be issued. Issued By: _ Date: sh=ot Expires: ny1n�n�� ooll.2ot4, POWT DONSITE WASTEWATER TREATMENT SYSTEM (OWTS) EH/NR CONSTRUCTION PERMIT APPLICATION 76 Service Center Rd Aspen, CO 81611 Phone: 970.920.5070 Fax: 970.920.5374 Parcel ID# (available from the Pitkin County Assessor's Office 2l 970-9205160 or at vrww.oitkinassessor.oro): _ H O _ O Purpose of Permit. NEW ❑ REPAIR DUE TO FAILURE ❑ REMODEL/ADDITION ❑ TANK ONLY ❑ FIE D ONLY Cost of System Repair or Remodel/Addition (approximate). $pa�4p Property Address: Business Phone: Lot: Block. Filing. 13 Subdiyy{{Sion: K Wel • scr -t- Sl.� Property r(s)': LLa Em dress In 1 \'l TY�25j jVl $CtIwA(�. •COM Ovmer's Mai ingd sss rea bill C� p� � CiCty,, State, Zip: O LiI Home Phone:'f 5-?l� 303- 8ac� Business Phone o- �n l- lbL 'Contact information must be provided for the owner signing this application. Primary Contact Person/App�li�ent pQf of owner): - bm Vv\wtCh t Com appy / hc�I✓L �uJ5 LCL Contact/Applicant MieillG�in3g Add $pa�4p Cell Phone: Business Phone: Fax Number: t� Email Address �- y>^w'(i�. r1'LS n, c -s.•.- Building Permit # (if applicable): 3.20 ? PR3K Lot Size (in acres): I a I Ln I ^ e -::, Size of Building (square feet): 3H S3 2L� GI Number of Potential Bedrooms: L, 32 Date: Applicant Signature: Detached Accessory Unit? ❑ YES NO Size of Accessory Unit (square feet). Number of Potential Bedrooms In or Fixture List for the Accessory Unit: ir\ Water Source: p(I �..,( PRIVATE WELL [I SURFACE WATER ❑SPRING ❑COMMUNITY/PUBLIC WATER SYSTEM Name of Community/PublicCiWater System (if applicable): ri Engineering Firm: Job Number. Phone Number Fax Number H -P C�k�h �7� ��\�?9�8 c��o�i�tS 7sLls`1 Mailing Addr ss: Cit ,State, Zip: sew c 1(t- [Ti H lo•.w t c. s, Cg, is I 1 PLEASE READ BEFORE SIGNING: 1 certify that the above Informatio is com tete and accurate and that I have provided complete and accurate information in all of the documents In e n yap Ilcadon pee ge. I accurate, 16 or misleatll Infor I ec no a on. ledge that EH/NR may revoke any permit I am issued if my application is found to contain any understand that no construction may be undertaken on an OWT9until an OWTS Construction Permit is sued. ignatur (Re Ired): Date: Applicant Signature: Date frill h1. ff—OWMME USE ONLY Received by EN/HR Staff: Fee & Receipt #: Dale. (O2 355*q- A&MIN Architects maE PNASE DR CIE: CHCKD HC 3NI3 K 115 MG PROJECT: 13-001 camr+n®ndourtule»�nalt rres RRRwxc s xor r5 eR IHD RA IARI.Ic Mr RaRoaxuw u®ca. an InR mxlwcnla Mr Ba1b14 w111RU1 a6I0KRMIC 1rF wNllal RERNASSgN a FxE arrrvaw MW M Iwmoartuxuxxlrtcrs oo xmuaf aulwrs, RNIMiNN Mcwxns sxm AFSPoNS.IF f at FRRIX4 alE N Sal® CRRPO RafR MIA01 SCA aSCREFMCIR10MDlwIPNMaxiRCR 089Rf SEMI aCpSIRLSIIOK IO■ 1L' r' 1.1 CDW4 �,e•^fix Stibb 1 ote rl 1 HEPWORTH-PAWLAK GEOTECHNICAL 0 11, pv.n111 V.o'1A i,,. i,. I,ni�_.iI a; — jr,'Ii ONSITE WASTEWATER TREATMENT SYSTEM DESIGN PROPOSED RESIDENCE LOT 13, RUEDI SOUTH SHORES PITKIN COUNTY, COLORADO JOB NO. 113 129B JULY 19, 2013 PREPARED FOR: HALLMARK CUSTOM HOMES, LLC ATTN: TOM MATTHYS 163 CASTLE GROVE PLACE CASTLE ROCK, COLORADO 80108 t2matthVs(iumsn.com Parker 303.641.7119 • Coloradu Springs 719-633.5562 • Silverrhorne 970-468-1989 TABLE OF CONTENTS PURPOSE AND SCOPE OF STUDY........................................................................ - 1 - PROPOSED CONSTRUCTION................................................................................. - 1 - SITECONDITIONS................................................................................................... - 1 - PERCOLATION TESTING AND SUBSURFACE CONDITIONS ............................ - 2 - OWTSANALYSIS........................................:........................................................... - 2 - -SEPTSEPTIC IC TANK........................................................................................................... - 3 - SEWER -SEWER AND EFFLUENT PIPING........................................................................... - 3 - -ABSOABSORPTION -SUBSRPTION AREA................................................................................................ - 4 - SUBSURFACE URFACE DRAINAGE.:................................................................................... - 5 - -LIMIOWTSMAINTENANCE........................................................................................... - 5 - LIMITATIONS TATIONS.......................................................................................................... - 6 - FIGURES - FIGURES FIGURE 1- OWTS SITE PLAN FIGURE 2 - ABSORPTION AREA CALCULATIONS FIGURE 3 - ABSORPTION AREA PLAN VIEW FIGURE 4 -ABSORPTION AREA CROSS SECTION ATTACHMENTS VALLEY PRECAST SEPTIC TANK DETAIL is • 0 PURPOSE AND SCOPE OF STUDY As requested, Hepworth-Pawlak Geotechnical, Inc. has designed an Onsite Wastewater Treatment System (OWTS) for the proposed residence to be located on Lot 13, Ruedi South Shores, Lake View Drive, Pitkin County, Colorado. The study was conducted in accordance with our agreement for geotechnical engineering services to Hallmark Custom Homes, LLC dated June 5, 2013. The data obtained and our OWTS design recommendations based on the proposed construction and subsurface conditions encountered are presented in this report. We previously performed a subsoil study and percolation test for the proposed residence and septic absorption area, and presented our findings and recommendations in a report dated June 28, 2013, Job No. 113 129A. PROPOSED CONSTRUCTION The proposed residence will consist of a two story wood framed structure over crawlspace level and located on the site as shown on Figure 1. The residence will have a total of three bedrooms and a bunkroom. The OWTS will provide service to all levels of the residence. SITE CONDITIONS The lot is vacant and bisected by Lake View Drive, see Figure 1. The proposed building area is located east of Lake View Drive and vegetated with sage brush, grass and weeds. The ground surface slopes down to the northwest at a grade of about 10 to 15 percent in the building area. Elevation difference across the proposed residence is about 12 feet. Scattered cobbles and boulders were observed on the ground surface. The septic disposal field area to the west of Lake View Drive has similar site and slope conditions. Job No. 113 129B Lf C�c�tech • -2- 0 PERCOLATION TESTING AND SUBSURFACE CONDITIONS For the previous percolation test, one profile pit and three percolation test holes were excavated at the approximate locations shown on Figure 1. The subsoils exposed in the Profile Pit consisted of about two feet of topsoil overlying intermixed sandy clay and gravel with cobbles to the pit depth of 7%z feet. No free water was encountered in the pit when excavated on June 5, 2013. The percolation testing results were provided in our previous report with an average percolation rate of 45 minutes per inch obtained. A gradation/hydrometer analyses was performed on the bulk sample of the subsoils from the Profile Pit to determine the United States Department of Agriculture (USDA) soil classification. The natural soils classify as Very Gravelly "SANDY LOAM" per USDA. The Long Term Acceptance Rate (LTAR) for SANDY LOAM from Table 6.28-4 of the State of Colorado Regulations is 0.72 gallons per square foot per day. Based on the percolation rate and SANDY LOAM soils, a percolation rate of 45 minutes per inch (MPI) was recommended. OWTS ANALYSIS Based on the subsurface conditions encountered and the percolation test results, the area at Profile Pit is suitable for an OWTS utilizing Infiltrator Chambers and the shallow soils for the treatment and dispersal of effluent. A percolation rate of 45 MPI will be used for sizing of the absorption area. The effluent will gravity flow to the absorption area. A site plan showing the proposed OWTS, proposed residence, building envelope, and the minimum horizontal setback distances of site features relative to the OWTS components is provided on Figure 1. The proposed residence will have 3 bedrooms with a bunkroom and we estimated 2% persons per bedroom for determining total design flow. All materials and installation should meet the requirements of the current Pitkin County Onsite Wastewater Treatment System Regulations. Job No. 113 129B 4 Go�gbE'ch f 0 -3- SEPTIC TANK A concrete 1,500 gallon, two chamber, Valley Precast septic tank, or equivalent, will be used for primary treatment of sewage from the residence. A detail o f the tank is provided as an attachment to this report. The tank will be located west of the proposed residence and east of Lake View Drive. An effluent filter will be installed on the outlet of the second chamber of the septic tank. Sewage will gravity feed from the residence to the septic tank and effluent will be gravity fed to the absorption area. The tank should be set level and bedded as necessary with compacted road base. if the septic tank access riser lids will be installed at grade, with no backfill cover, then the lids should be insulated with foam insulation board to provide frost protection. The sewer pipe inlet tee in the first chamber of the septic tank should be installed beneath the access lid of the first chamber of the septic tank so that it can be reached for service should it become clogged. The PVC handle on the effluent filter should be extended up to within reach of the second chamber access riser lid. This will allow for easy access and maintenance of the filter. Approximately 2 feet of soil backfill cover should be placed over the top of the septic tank to allow for easy access and frost protection. For maintenance reasons deep tank installations should be avoided and we should be contacted to evaluate our design should it appear that a deep tank installation involving more than 4 feet of backfill over the top of the septic tank may be required. SEWER AND EFFLUENT PIPING The sewer line from the proposed residence to the septic tank should not be less than the diameter of the building drain and not less than 4 inches in diameter and will service all levels of the proposed residence. Soil backfill beneath the sewer pipe must be adequately bedded and compacted to prevent settlement of the pipe. The sewer pipe should be installed in landscape areas with at least 2 feet of soil covering the pipe, or the pipe should be insulated on the top and sides with 2 inch thick rigid foam insulation board for frost protection. Beneath driving surfaces, Schedule 40 PVC sewer pipe should be used and the pipe should be insulated if it will be installed with less than 4 feet of soil cover. Job No. 113 129B C-199itech 0 0 -4- We recommend the use of Schedule 40 PVC pipe between the proposed residence and the septic tank, though this is not required by local regulations. The portion of the sewer pipe extending from 5 feet outside the building foundation should have a slope of at least 2%. Cleanout pipes should be installed in the sewer line adjacent from the building foundation, adjacent to the inlet of the septic tank, where the sewer pipe bends at 90 degrees or more, and at least one cleanout should be installed at least every 100 linear feet of non -pressurized sewer or effluent pipe throughout its length. We recommend that a straight section of pipe be installed between the residence foundation and the septic tank. Any required 90 degree bends in the sewer pipe should be accomplished through the use of a series of 45 degree smooth elbows or a 90 degree long sweep to help prevent clogging of the pipe. ABSORPTION AREA The absorption area calculations are shown on Figure 2. The soil absorption area was designed to be 1520 square feet and will have 7 absorption trenches consistin of154 Infiltrator Quick 4 Standard chambers as shown on Figures 1 and 3. Each chamber was given 9.87 square feet of absorption area per Pitkin County regulations. A 30% reduction was applied for using Infiltrator Quick 4 Standard chambers in a trench configuration. The trenches will each contain 22 chambers and will be combined in a serial distribution mem. The absorption trenches should be excavated to the approximate depths shown on Figure 4. The trench excavations must follow the natural contours on-site. Care must be taken during installation to ensure that the soils exposed in the bottom and sidewalls of the trench excavations are not compacted. Once the trench excavations are complete, the trenches should be left open, if necessary, to allow the soils to air dry prior to placement of the Infiltrator chambers and distribution pipes. After the soils have air dried, the bottom and sidewalls of the excavations should be scarified prior to placement of the / chambers and piping. le511 A &,ek.4 miJi,fP/M �S j�or o, 5 6Q_Ar00"-\ I(O �] Son Job No. 113 129B -5 - The on-site soils, devoid of oversized rocks, can be used as backfill over the chambers and should be graded to deflect surface water and precipitation away from the absorption area. We recommend the soil backfill be re -vegetated as soon as possible with a mountain meadow grass mix or suitable equivalent. It is important not to plant large vegetation or vegetation with invasive roots in and around the absorption area and piping as the roots may damage piping. Combination air vent/inspection ports should be installed at each end of the absorption trenches. The ports should be constructed of 4 inch diameter PVC pipe installed into the knockouts provided on the tops of the Infiltrator chambers. The ports should extend a minimum of 8 inches above the ground surface and should have ventilated removable caps. The absorption area distribution piping layout and serial trench connections is shown on Figure 3. All materials used and installation methods should meet the requirements of the current Firkin County Regulations for Onsite Wastewater Treatment Systems. SUBSURFACE DRAINAGE No free water was encountered in the profile pit when excavated on June 5, 2013 and it is our opinion that a subsurface drain will not be required. If free water is encountered in any excavations on the site we should be notified to re-evaluate the need for a subsurface drain to protect the absorption area. OWTS MAINTENANCE The OWTS will require maintenance. The level of maintenance will vary with the complexity of the system and water use habits of the users. We recommend that fat, oils, bath oils, greases, paint, solids, water softener backwash solution, water from hot tubs and other constituents that can clog and foul collection and disposal equipment are not disposed of in the residence drains. The absorption area and any areas directly up gradient should not be watered by lawn irrigation systems or other means as the soils may become hydraulically overloaded. The septic tank should be pumped whenever the Job No. 113 129B G(�'JtEch 0 -6- sludge occupies 1/3 of the liquid capacity of the fust chamber of the septic tank. In addition, the effluent filter should be checked for clogging at least once per year and cleaned as necessary. We recommend that an operation and maintenance manual be developed for the OWTS. The system should be operated and maintained as stipulated in the manual. We can prepare the operation and maintenance manual if desired. LIMITATIONS This design has been conducted in accordance with generally accepted engineering principles and practices in this area at this time. We make no warranty either express or implied. The conclusions and recommendations submitted in this report are based upon the data obtained from the profile pit excavated at the location indicated on Figure 1 and to the depth shown on the attached percolation testing report, the proposed type of construction and our experience in the area. Our findings include extrapolation of the subsurface conditions identified at the profile pit and variations in the subsurface conditions may not become evident until excavation is performed. If conditions encountered during construction appear different from those described in this report, we should be notified at once so re-evaluation of the recommendations may be made. Based on site reconnaissance, it is our opinion that the designed location of the OWTS does not violate any setback requirements of the current Pitkin County Environmental Health Department's regulations. We recommend that the position of the OWTS components, proposed residence and setback requirements be verified in the field by a Professional Land Surveyor licensed in the State of Colorado. This report has been prepared for the exclusive use by our client for the OWTS design submittal process. We are not responsible for technical interpretations by others of our information. As the project evolves, we should provide continued consultation and field services during OWTS construction to review and monitor the implementation of our recommendations, and to verify that the recommendations have been appropriately interpreted. Pitkin County requires that an As -Built evaluation of engineered OWTS designs be performed by the OWTS engineer. We should be contacted to perform Job No. 113129B _--- _5pt 0 -7- Ll the OWTS As -Built evaluation at least 48 hours in advance. You must obtain the required OWTS permit from Pitkin County prior to our As -Built inspection. Prior to evaluation, all system components should be installed including: sewer pipe, effluent pipe, septic and dosing tanks, effluent filter, inlet and outlet tees, pump, Infiltrator chambers and distribution and manifold piping. No components of the OWTS should be backfilled prior to our performing the As -Built evaluation. Please contact us for any necessary revisions or discussion after review of this report by the Pitkin County Environmental Health Department. If you have any questions, or if we may be of further assistance, please let us know. Respectfully Submitted, HEPWORTH - PAWLAK GEOTECHNICAL, INC. 1AA - RobertE. Stempihar, P.E. Reviewed 1 -- David A. RES/ksw JOo No. 113 1296 Ia �gter_h 13 OM �o g g iQomgggg Oy d-5 FF y�{i4 Vol- §� gt apr,, y 2 Dti. iRi� a _n ~p��n Fi $$ o N � �yy a € FA aPRa Z 3 N A O m xa axoxe� x \ � 44 Sv a�7 m ~p��n Fi py�nM a € FA aPRa € N A O Ci xa axoxe� x \ � 44 Sv a�7 0 0 OWES ABSORPTION AREA CALCULATIONS In accordance with the current Pitkin County Environmental Heafth Department's On -Site Wastewater Treatment System Regulations, the absorption area was calculated as follows: Q = (F(B)(N)(I.5) 1011 F=AVERAGE FLOW PER PERSON= 75 GALLONS PER DAY B = TOTALNUMBER BEDROOMS= 4 N = ESTIMATED NUMBER OF PERSONS PER BEDROOM 15 CONSTANT= ESTIMATED DESIGN FLOW EQUAL TO I50%OFAVERAGE DAILY SEWAGE FLOW = 1.5 GALLONS PERDAY Q = TOTAL DESIGN FLOW= 1125 GALLONS PER DAY ABSORPTION AREA CALCULATIONS• t = SOIL PERCOLATION RATE IN MINUTES PER INCH (MPD = 45 CONSTANT = 5 P = LOADING FACTOR 14 A=POft03l 5 A= MINIMUM ABSORPTION AREA AGGREGATE SUE= 2113 SQUAREFELT ABSORPTION AREA RED CTIONS REDUCTION FACTOR FOR CHAMBERS = 0.7 up to 30% MINIMUM ABSORPTION AREA AGGREGATE SIZE WITH REDUCTION= 1479 SQUARE FEET ABSORPTION TRENCH CONFIGURATION AMOUNT OF ABSORPTION AREA GIVEN TO EACH CHAMBER = 9.87 SQUARE FEET MINIMUM NUMBER OF CHAMBERS = 150.0 CHAMBERS NUMBER OF TRENCHES = 7.0 NUMBER OF CHAMBERS PER TRENCH = 22 TOTAL NUMBER OF CHAMBERS = 154 A=ACTUAL ABSORPTION AREA A(GRDGATESIZE= 1520 SQUARE FM 113 129B ABSORPTION AREA CALCULATIONS I FIGURE 2 • 0 SEVEN PROPOSED ABSORPTION TRENCHES CONNECTED VIA SERIAL DISTRIBUTION. EACH TRENCH CONTAINS 22 INFILTRATOR STANDARD QUICK 4 CHAMBERS (154 CHAMBERS TOTAL) FOR 1520 SQAURE FEET OF ABSORPTION AREA. 4 -INCH NON -PERFORATED PIPE SLOPED AT 2% MINIMUM FROM ABSOPRTION TRENCH CHAMBER TO ADJACENT ABSORPTION TRENCH CHAMBER FOR PROPER SERIAL DISTRIBUTION. 4 -INCH DIAMETER PVC AIR VENT INSTALLED VERTICALLY INTO KNOCKOUTS IN INFILTRATOR CHAMBERS. REMOVABLE COVER TO BE PLACED ON TOP OF PIPE. TOP OF PIPE TO BE VENTILATED WITH AT LEAST TWELVE, Y2 -INCH HOLES. VENT SHOULD STICK UP AT LEAST 8INCHES FROM FINISHED GRADE. INSTALL VENTS AT EACH END OF EACH TRENCH. FROM SEPTIC TAlVk INFILTRATOR END PLATE NOTE: ALL INSTALLATION MATERIALS AND METHODS TO MEET CURRENT PITKIN COUNTY OWTS REGULATIONS. 113 129B ABSORPTION AREA PIAN VIEW I FIGURE 3 = tiQ 4 -INCH NON -PERFORATED TRANSPORT �= PIPE SLOPED AT 2% MINIMUM TO DRAIN FROM THE SEPTIC TANK OUTLET DOWN 4 TO THE FRIST ABSORPTION TRENCH ? h W INLET. INFILTRATOR END PLATE NOTE: ALL INSTALLATION MATERIALS AND METHODS TO MEET CURRENT PITKIN COUNTY OWTS REGULATIONS. 113 129B ABSORPTION AREA PIAN VIEW I FIGURE 3 0 • 1334 NI 31VOS 31VWIXOHddV sass uo sauilapin0 AfunoO uiUd luenno a ayl I"w Heys spoy19w uol1elle)sul pue sleusIew Tuldld IIV 't :S3LON 2 M OL 0 Z) LL W 2 0 ft 0 sH3ewVHo ao1VH11Idw ma dO 1N3W30V1d Ol UOlkdd 30V=lUnS LL ONWH'O AJ18VOS ONV 13A3131VAVOX3 O Z ios3vivN SH38WVH000lVUru=iNl F _ IK)S 3ALIVN a311V1SNl 3Hl 83AO 83AOD IIOS V 1110621AUft100d L VMNINIW V 39 ISM 383H1 co a 30VdHf1S 3avuE) DNIISIX3 3Hl WOHd 0 NFA ».a rwve NOI1dHOS8V HOV3 j0 3SV801InO 133d E Ol Z 31VWIXOHddV aC rL—_HON381 +�oNusxe �vwxaeaav U dd0-NRH H31VM 30V=Iuns '`JNINNI'J38 1031d30 01030VHJ 38 HON3H11N30Vr0V Ol ON3 HON3Hl NOW OInOHS IIOS H3A00 wNld W(1WINIW %Z 1V 03dO1S 3dld NOLLf18Id1Sla -MESS 0Ad 031VHOdH3d-NON HONI.4 /30VUE) 03HSINId WOHJ S3HON191SV31 iV dfl MOLLS mnoHS 1N3A'S310H HONIJ'3A13ML 1SV371V HAM 031VIl N3A 38 Ol 3dld d0 dOl Adld d0 d01 I NO a33Vld 38 OI H3AOO 318VAOW3H'S838WVH0 NO InO-H00NX OMAOHd O1NI A11VOLL83A 03TN1SNI 1N3A HIV OAd H313WM0 HONI-4 Item # 7SOOT-2CP TOP View Section View 0 r 0 1500 Gallon Top Seam Two Compartment TO' CiaerAwm �leq Hole Lid a Fan" l 'Masts ASTM 04227 spec Includ ft 011844-08 for resIUM connectors • 4000 pal concnft • Delkwed complete wfth internal pipkv • PVC, poly or coruxeW risers available • Optlon of pump or siphon hate W aa�rpavm bwt ob ao�. 1WLonexa'Wlde Inbt Durst LeryMh Wldlh HdQM L - below kft w 5V 1sr ee' etP n.twtgrd Lld _ 7Ynlc Tell 8,t001bs 11,1!0 bs 14,780 bs wabr & (719)e7e4 2=Cm Fid 317 wntr* K P.O. BWw ® VALLEY a Products Fac: (719) 3W,%WV ��q'0081211 PRECAST, Inc. • swim � ftnW@*WM. lq kdst9lde 1,002 pepprr Ou1et91ds =go" TOW 1,606 Astons n.twtgrd Lld _ 7Ynlc Tell 8,t001bs 11,1!0 bs 14,780 bs wabr & (719)e7e4 2=Cm Fid 317 wntr* K P.O. BWw ® VALLEY a Products Fac: (719) 3W,%WV ��q'0081211 PRECAST, Inc. • swim � ftnW@*WM. lq 0 0 OWTS DESIGN CALCULATIONS - for Pitkin Owner's Name Parcel ID # House Size (sq. ft) (75 gpd or 100 gpd) T Number of Bedrooms in Main House 5 Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House 0 Number of Bedrooms in Detached Caretaker unit 0 Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit 0 (if the caretaker unit is ATTACHED, treat as if part of main house.) Average Daily Waste Flow 750 State Review Required? no Per: Rate (I) Design How (Q) = # potential bedrooms X 2 people/bedroom X gpd X 1.5 Q= 1125 Minimum tank capacity 1406 gallons Absorption Area (=Q/5 X SART pert rate)(1.4 loading factor) A = 2,113 sq. ft. of absorption area required Absorption Area (=Q/5 X SQRT perc rate) WITH SECONDARY TREATMENT (no loading factor) A= 1,509 sq. ft. of absorption area required Abs. Area w/ loading factor (B25) Trench Bed Quick4 Trench Qmck4 Bed Pipe and Gravel (-10%) 1902 red. 2113 193 214 Dosing (-20%) 1690 (40%) 1690 171 171 Chambers (-30%) 1479 (-10%) 1902 150 193 Max Allowable (-50%) 1057 (-30%) 1479 107 150 Secondary Treatment Abs Area w/ out loading factor (B28) Trench Bed Pipe and Gravel (-10%) 1358 m md. 1509 138 153 Dosing (-20%) 1207 (-20%) 1207 122 122 Chambers (-30%) 1057 (-10%) 1358 107 138 Max Allowable (-50%) 7M5 (-30%) 1057 76 107 110 SETBACK FROM WELL # of feet = 60 SETBACK FROM POND, STREAM OR IRRIGATION DITCH # of feet = 35 SETBACK FROM DRY GULCH # of feet = •YfaQmarf custom xomes ccc O 1263 Castle Grove Place Castle Rock. CO 80108 303-435-9723 Cell 720-733-9319 Fax H all m arkcustom homes.biz tgmalthysr&.msn.com February 25, 2014 Kurt Dahl Pitkin County Dept. of Environmental Health 76 Service Center Road Aspen, CO 81611 Mr. Dahl Attached is a completed OWTS Construction Permit Application and related documents. We submitted for permit in December and apparently missed this step in the process for submission despite having all the work in hand on the date of permit submission. Property is on Lot 13 Ruedi South Shores, near Meredith. Property address still not assigned. Please review the attached and contact me with any questions or requests for added information. Sincerely, Tom Matthys 303-435-9723 L � ��(/�h Hepworth -Paw ak Geotechnical, Inc. ' M/VVtV1►� ■ 5010County5o7 154 Glcnwtxxl Springb, Colorado S1601 Phone: 9/0945.79RF HEPWORTH-PAWLAK GEOTECHNICAL Fax: 970-945•8454 email: 1711golt'r-blhpgeotech.com September 18, 2014 Hall Custom Homes, LLC Attn: Tom Matthys 163 Castle Grove Place Castel Rock, Colorado 80108 (t matthys c().msn.com) Job No. 113 129B Subject: As -Built Evaluation of On-site Wastewater Treatment System, Lot 13, Ruedi South Shore, Lake View Drive, Pitkin County, Colorado Dear Mr. Matthys: As requested by Joe Zamora, Hepworth-Pawlak Geotechnical, Inc. observed the installation of the Onsite Wastewater Treatment System (OWTS) for the proposed residence on the subject site. The OWTS components observed include: effluent pipe, infiltrator chambers, inspection ports, and the locations of the observed components. We previously designed the OWTS for the subject site and presented our recommendations in a report dated July 19, 2013, Job No. 113 129B. Our observations and recommendations are presented in the following paragraphs. We performed our As -Built site evaluation on August 11, 2014. We met with Joe Zamora at the site this date. At the time of our site visit, the contractor had installed and buried the effluent line from the house to the septic tank and from the septic tank to the absorption field. The top of the tank was exposed. There is an approximate 6 foot drop in elevation in the 30 foot distance between the house and the septic tank. There is another 6 foot drop in elevation in the 58 foot distance between the tank and the absorption field. The septic tank is reportedly a 1500 gallon precast two chamber tank equipped with an effluent filter in the second chamber. We confirmed that the tank has two chambers and the tees were in place at both the inlet and outlet of the tank. The effluent filter was in place at the outlet tee. The piping from the house to the absorption field was backfilled but reportedly consisted of all 4" diameter Schedule 40 PVC non- perforated sewer pipe. The trenches for the absorption field were completed with the infiltration chambers in place and mostly backfilled. The ends of each row of chambers were exposed. Trenches 4, 6 and 7 had not been backfilled. Seven lines of twenty-two standard Quick4 Infiltrator chambers were installed in the serial distribution disposal area trenches. An inspection port consisting of a vertical 4" schedule 40 pvc pipe with cap rising above the finished ground surface was installed in a knockout on each of the end infiltrator units. The infiltrator units and effluent pipe were installed at a depth of approximately 2 to 3 feet below the top of the trench. Minimum depth of soil cover in our report for the infiltrator Parker 303-841-7119 • Colorado Springs 719-633-5562 • Silverthorne 970-468-1989 Do Hall Custom Homes, LLC September 18, 2014 Page 2 units was 1 foot. Measurement with a 4 foot construction level at the pipe from the septic tank to the absorption field and at six locations along the effluent pipe between the infiltrator trenches indicated positive drainage into each of the infiltrator units. The components noted above were observed to be located generally as shown on the attached OWTS As -Built Site Plan. It is our opinion that the installed OWTS meets the general intent of our July 19, 2013 design report. The OWTS As -Built Site Plan is shown on the attached Figure 1. An As - Built Photo Log is also provided as an attachment. The observations and recommendations presented above are based on our site observations and our experience in the area. We make no warranty either express or implied. Alterations to the system including backfill and site grading could alter the operation and effectiveness of the OWTS. On-site observations of the OWTS backfill, recommended corrections or other out of scope services can be provided for an additional cost. Please feel free to contact us if you have any questions regarding this letter. Sincerely, HEPWORTH - PAWLAK GEOTECHNICAL, INC. I Daniel E. Hardin, P.E. Rev. by: David A. Young, P.E. �V•: 32-216 Attachments: Figure 1 — OWTS As -Built Site Plan As -Built Photo Log Job No. 113 1296 aI nu i uiiii' �ru o � v I AS -BUILT PHOTOGRAPH LOG August 14, 2014 Job No. 113 12913 a3 Photograph 1: Looking West Cleanout adjacent to house. Tank to left. Absorption field between truck and backhoe. Photograph 2: Looking West 1500 Gallon Tank Photograph 3 Looking Northwest 1500 Gallon Tank I ' . I AS -BUILT PHOTOGRAPH LOG Job No. 113 129B Qq Photograph 4: Looking South Trench #1 with Trench #2 to right. Twelve %" holes drilled in vent cap. Photograph 5: Looking South Trench #3 with Trench #4 to right. Photograph 6: Looking South Trench #4 with Trench #5 to right. AS -BUILT PHOTOGRAPH LOG August 14, 2014 Job No. 113 12913 Photograph 7: Looking South Trench #6 Photograph 8: Looking South Trench #7 Cgted l H 28, 2013 PAWLAK GEOTECHNICAL �„-'o, 4; _I;� Hall ark Custom Homes LLC Attn: Tom Matthys 163 Castle Grove Place Castle Rock, Colorado 80108 Job No. 113 129A Subsoil Study for Foundation Design and Percolation Test, Proposed Residence, Lot 13, Ruedi South Shore, Pitkin County, Colorado Mr. Matthys: As r�quested, Hepworth-Pawlak Geotechnical, Inc. performed a subsoil study and. test for foundation and septic disposal designs at the subject site. The study was Onducted in accordance with our agreement for geotechnical engineering services to Custom Homes LLC dated May 2, 2013. The data obtained and our based on the proposed construction and subsurface conditions are presented in this report. Chen and Associates Inc. previously performed a proiminary geotechnical study for the subdivision and reported their findings in a report July 28, 1983, Job No. 24,838. Construction: The residence will be a two story wood frame structure over a craw'space located on the lot approximately as shown on Figure 1. Cut depths are i expected to range between about 3 to 6 feet. Foundation loadings for this type of consiruction are assumed to be relatively light and typical of the proposed type of construction. The on-site septic disposal system is proposed to be located west of the roadway and downhill of the residence as shown on Figure 1. If building conditions or foundation loadings are significantly different from those described above, we should be notified to re-evaluate the recommendations presented in this r�port. PSIrkt!i- 303-ti41-7110 • 119-633-7562 • Sihcnhurnc 910-468-1189 6) 0 0 -2- Site Conditions: The lot is vacant and bisected by Lake View Drive, see Figure 1. The proposed building area is located east of Lake View Drive and vegetated with sage brush, grass and weeds. The ground surface slopes down to the northwest at a grade of about 10 to 15 percent in the building area. Elevation difference across the proposed residence is ab ut 12 feet. Scattered cobbles and boulders were observed on the ground surface. The sep is disposal field area to the west of Lake View Drive has similar site and slope Irface Conditions: The subsurface conditions at the site were evaluated by sting two exploratory pits in the proposed building area and one profile pit in the sed septic disposal area at the approximate locations shown on Figure 1. The logs pits are presented on Figure 2. The subsoils encountered, below about 2 feet of nic topsoil, consisted of intermixed sandy silty clay and gravel with scattered cobbles were stiff/medium dense and extended down to the pit depths of 7'/z to 8%2 feet. Ilts of swell -consolidation testing performed on relatively undisturbed samples of the portion of the subsoils, presented on Figure 3, indicate low to moderate sibility under conditions of loading and wetting with a low hydro -compression when wetted. Results of gradation analyses performed on disturbed bulk sam les of sandy clay and gravel soils (minus 1 %2 inch fraction) obtained from the pits are pres nted on Figures 4 and 5. The laboratory test results are summarized in Table 1. No free Iwater was observed in the pits at the time of excavation and the soils were slightly moist to moist. Foundation Recommendations: Considering the subsoil conditions encountered in the exploratory pits and the nature of the proposed construction, we recommend spread footings placed on the undisturbed natural soil designed for an allowable bearing pressure of 1,500 psf for support of the proposed residence. The soils may tend to compress some when wetted and precautions should be taken to prevent wetting. Settlement could be up to 1 io 1'/2 inches depending on the depth and extent of the wetting. Job N4. 113 129A a-3 I. gnech -3- 0 Footings should be a minimum width of 18 inches for continuous walls and 2 feet for col mns. Loose and disturbed soils encountered at the foundation bearing level within the excavation should be removed and the footing bearing level extended down to the undisturbed natural soils. The footing subgrade should then be moistened and compacted. ExI erior footings should be provided with adequate cover above their bearing elevations for frost protection. Placement of footings at least 42 inches below the exterior grade is typ Cally used in this area. Continuous foundation walls should be well reinforced top and bottom to span local anomalies such as by assuming an unsupported length of at least 12 Feet. Foundation walls acting as retaining structures should also be designed to resist a lateral earth pressure based on an equivalent fluid unit weight of at least 50 pcf for the on- site soil, excluding topsoil and plus 8 inch size rocks, as backfill. A representative of the gco echnical engineer should observe all footing excavations prior to concrete placement to aluate bearing conditions. Slabs: The natural on-site soils, exclusive of topsoil, are suitable to support lightly d slab -on -grade construction. To reduce the effects of some differential movement, slabs should be separated from all bearing walls and columns with expansion joints i allow unrestrained vertical movement. Floor slab control joints should be used to e damage due to shrinkage cracking. The requirements for joint spacing and slab should be established by the designer based on experience and the intended use. A minimum 4 inch layer of sand and gravel should be placed beneath slabs at e for support and to facilitate drainage. This material should consist of minus 2 inch gate with less than 50% passing the No. 4 sieve and less than 12% passing the No. two All ill materials for support of floor slabs should be compacted to at least 95% of ma 'mum standard Proctor density at a moisture content near optimum. Required fill can co ist of the on-site soils devoid of topsoil and oversized rocks. Unerdrain System: Although free water was not encountered during our exploration, it has I een our experience in the area and where clay soils are present that local perched Job D8 ILJ IGY/i a a a cl r r' Sao' x PIT 200000/ /P -1z / i I ,P-2 .iarnna o: P-3 ' rwr wr PROFILE PIT I n�a y � � Y <m• L 1� \ PIT 1 au�n / � mP tlsYi ul APPROXIMATE CALF: 113 129A GE'.CPt@C�'1 LOCATIONS OF EXPLORATORY PITS AND FIGURE 1 HE WORiHfAWLAKGEOTECHHICAL PERCOLATION TEST HOLES a cl 3O Sl 3-3 } f ( 2 / /) / >1 cu // \\ � \ 2§| _ \/§ £ )) E 2 § ! § kn § 4&� IE§ r§ G 3 _;. ) IT\ k2 � � ) HEPWORTH-PAWLAK GEOTECHNICAL, INC. TABLE 2 PERCOLATION TEST RESULTS JOB NO. 113 129A HOLE NO. HOLE DEPTH (INCHES) LENGTH OF INTERVAL (MIN) WATER DEPTH AT START OF INTERVAL (INCHES) WATER DEPTH AT END OF INTERVAL (INCHES) DROP IN WATER LEVEL (INCHES) AVERAGE PERCOLATION RATE (MIN./INCH) Pi 49 15 7 51/2 11/2 45 51/2 5 1/2 5 41/2 1/2 41/2 41/4 1/4 41/4 4 1/4 4 31/2 1/2 31/2 31/4 1/4 P2 47 15 71/2 6 11/2 45 6 51/2 1/2 51/2 5 1/2 5 41/2 1/2 41/2 41/4 1/4 41/4 4 1/4 4 3 1/2 1/2 P3 45 15 71/2 61/2 1 45 61/2 6 1/2 6 51/2 1/2 51/2 5 1/2 5 4 1/2 1/2 4 1/2 4 1/4 1/4 41/4 4 1/4 Note: Perc lation test holes were hand dug and soaked on June 5, 2013. Percolation tests were cond cted on June 6, 2013 by HP Geotech. The average percolation rates were based on the last t, ree readings of each test. 3 -I JUND #5 REBAR 8 PLATIC CAP L.S. 014111 GRAPHIC SCALE co c w Bo zo CIN FEET) OPEN SPACE m lw HAISTII1p COISDITIOIiS/PGRTIGL iOYOGRGPHICGL MGP OF: Ad& MTN LOT 13, RUEDI SOUTH SHORE Architects' rci ec s A PARCEL OF LAND SITUATED IN THE SW } OF SECTION 14, TOWNSHIP 8 SOUTH, RANGE 84 WEST OF THE 6TH P.M. CONSTUCTION EASEMENTS FOR PURPOSE OF ROAD REALIGNMENT S86'55'09'E 835.OT ORIGINAL BUILDING ENVELOPEI LOT I; SOUTH 543,490 SO. FT. 12.477 ACRES LOT 14 to.o' REVISED ACTIVITY ENVELOPE EDGd OF GRA EL ROAD rP) NBd55'OB'W i 418.01' LOT; COUNTY OF PnXIN, STATE OF COLORADO MILLER SHEET 2 OF 2 PROJECT BEXCW "M UNITED STATES CREEK 643'490 SO. Fr. ESTATES C 1/4 CORNER SEC. 14 FOREST SERVICE FOUND 1963 BLM BRASSCAP \ BASIS OF BEARING 1573.41' ELEV. 8007.79' 1162.70' V y °u 380.41' `IO.0' GENERAL PURPOSE UTILITY EASEMENT INSIDE ALL LOTS 30.0' WIDE ROAD PP4 O ALONG SOUTH SHORE DRIVE AND LAKE VIEW DRIVE i RIGHT-OF-WAY AND LYING ADJACENT TO BOTH SIDES OF SAID DRIVE GENERAL PURPOSE (SEE PLAT NOTE 3) UTILITY EASEMENT (SEE PLAT NOTE 2) 10.0' u OPEN SPACE CONSTUCTION EASEMENTS FOR PURPOSE OF ROAD REALIGNMENT S86'55'09'E 835.OT ORIGINAL BUILDING ENVELOPEI LOT I; SOUTH 543,490 SO. FT. 12.477 ACRES LOT 14 to.o' REVISED ACTIVITY ENVELOPE EDGd OF GRA EL ROAD rP) NBd55'OB'W i 418.01' LOT; MILLER CREEK ESTATES P4 x� V y °u z PP4 O u� u A Ac DRAW: DAM, GF+DOD MGF� PROJECT: 13-001 / (y SET CO+MIGHIFO GY MCLMAA:0.RCHreCR lM5 ' LINE GMwkG 15 NOT TO BE WED PoR MWNG MY REFAODUCi%N'Ni9ECF OA fOR CCNRl4C'ING ANYBNLOINGYMNOVF1l510BiAININ T wAlnEx'ERM ss�a: aF *xE cormGHr HW➢ER M0.N'AIN MCMIIFCS OON015CALi OMW�NGS MQA'IAINMti RCiS IS NCi C) ` rRu",N EE ra AW % OUW1N'u5.N9CR ANl CUES'1p150R CISLREPAHCR 10 Rgi�`AMAACF RCS Up PvWr i:�Mf SAR'OFCON5IR:.TON T� SCA_=_: AS VOTED zLm SITE 1 SHEET Owner's Acknowledgement The owner acknowledges being Informed by Pltkin County of the existence of environmental hazard areas that might affect the property, any Improvements and the use thereof. Randy Schumacher, Owner Community Development Director's Approval This Ruedi South Shores Lot 13 site plan has been reviewed and approved by the Community Development Director of Pltkl n County this_ day of 2013 and is subject to Community Development Directors Determination No. 20_ recorded as Reception Number J Cindy Houben, Director p�ivT FE Clerk and Recorder's Certificate This Ruedi South Shores Lot 13 site plan has been •c>m' / accepted for recording in the Office of the Clerk and Recorder Pitkin County, Colorado the_ day of I L-•—••-- —••— —•• // • 1• 20131n Platbook_ at page_ as —h•—•- - Reception Number i ACTIVITY ENVELOrE �Epe LEACH---------------�!----�- - 1 iRIEL7 r- Clerk an Recorder I I I r I I PRO-OSED LEAC-4 FIELD 5000 OF. ✓• -�' _ GRAPHIC SCALE Ac o 10 z. loo (IN FEET) EIISr Ni0 COFIDITTONS/PARTIAL TOPOGRAPHICAL MAP OF: �•� LOT 13, RUEDI SOUTH SHORE 8060 A PARCEL OF LAND SITUATED IN THE SW } OF SECTION 14, TOWNSHIP 8 SOUTH, RANGE 84 WEST OF THE 6TH P.M. �, \ COUNTY OF PITS:INI, STATE OF COLORADO \ SHEET 2 OF 2� X 8050 8070 8E1 NAr_ AND LAME ON PR Ar- _M5 L/ ELEVAT'ON 906';9' RE'AIN 3 P L'T- GRACE) xlerrNG GFtALJE r'Y=1 8070 GRA'JE rr=: 8080 OFFSET LINE ALMTN Architects CRAJN -'CF 9.16J3 Y� L212 •+O al.le (' PROJECT: 13-001 COPYNGNI®aYMWMAN ACHRCIS !M6 DMWND6NOr Te&. FDP xwtlN4 MY RMy BUIL IRN IIEAEOf. RF001MiM1WTW 4nellagNOWIMOf FAS OBI 0IFF W" ^FRMi55i0N RTE tAPRila••I 401M, MWMAINARMIYALE MS WR DMWINfiS MOLMIAINARC.N'1 MIS NT AESRdSiBLE iM FAA W s alit TO SGIFD DMMuss.AEfnANr WFs!px6oR oEta�Rmts ro M W'fAW 4�i ECa 3EmF s*up DFcaamucror 5CA_E: AS NOTED SITE 2 SHEET Sep 1013 09:06a Shelton Drilling Corp. • (970)927 18 1 PA WELL CONSTRUCTION AND TEST REPORT STATE OF COLORADO, OFFICE OF THE STATE ENGINEER FOR OFFICE USE ONLY APPROVAL a GWS31-91-03 I • WELL PERMIT NUMBER 288529 2. Owner Name(s): Randy Schumacher Mailing Address: 5680 Hackney Ct City, State, Zip: Parker, Co 80134 Phone # 3 WELL OCATION AS DRILLED )fir 1/4 SE 114 See: 14 DISTANCES FROM SEC. LINES Twp: 8 S Range: 64 W 6th PM ft. fiom Sec. line and ft. From Sec. line OR Easting: 3 50 156 Northing: 4357435 SUBDIVISION: Ruedi South Shores LOT: 13 BLOCK: FILING (UNM: STREET ADDRESS AT LOCATION 4 GROUND SURFACE ELEVATION ft. DRILLING METHOD Air Rotary DATE COMPLETED: 1 V82012 TOTAL DEPTH: 625 DEPTH COMPLETION: 500 5. GEOLOGIC LOG 6. HOLE DIAMETER (to) FROM (a) To (a) Depth Type of Material Siz Color, and 9.0 0 100 000022 Overburden 6.5 too 500 022-220 Gothic Formation 5.0 500 625 220-320 Leadville Limestone ?? Lost Circulation 7. PLAIN CASING 320-625 Chaffee Gro r OD (m) Kind WWI Sae Frain (a) To (ft) 7.0Steel 0.240 IDD 5.5 99-1 Steel 0.188 480 PERF. CASING : Saeen Slot Size 5.5 Steel 0.188 480 Soo Water Located: 540+ Remarks : 8. Filter Pack Material : Size : Interval 9. Packer Placement Type : Depth 10. GROUTING RECORD Material Amwnt Density lotavW Plac"ex"a Cement 7 sks 6 sk 10-40 poured 11. DISINFECTION : Type : HTH Amt. Used: 12 m 12. WELL TEST DATA : () Check Box if Test Data Is Submitted On Supplemental TESTING METHOD: Air Compressor Static Level : 381 ft. Date/Time Measured 11!82012 Production Rate 4 gpm Pumping Level : Total IL Date/Time Measured 11!82012 Test Length : 2 hours Tett Remarks: 13. fhWnadth5:M",wAckhmldkmwthcm mt&mo(=d"Umrm"lomykrawkdge.(Pu IWScatu24414(13Xm)CR&U.e NgotnWmlm eemtlNksOa(w u the temnd delta ad's pwatbebk a • cku I sifdemunot.) CONTRACTOR Shelton Drilling Corp. Phone: (970)9274182 Mailing Address: P.O. Box 1059 Basalt, C0,1011 I Lic. No. 1095 Nature /ride (Please Type or Print) Wayne Shelton / President gna Si ' Date 11/912012 0 APPENDIX E Small Scale Construction Management Plan for: Address « r3 p A ,,; F-f+,teC. Parcel ID Number .241 IHlol tit Permits Applied for: Check all that apply. Demolition Permit # _Building Permit # Access Permit # Earthmoving Permit # Floodplain Permit # ROW Permit Property Owner's Name - --.@tnf! j Sr.�r�,c�i a �. Name Phone Number Owner's Representative's Name: -rte, tJ1�•64r,, 3o31yIS, •-T-) Name Phone Number Emarl Contractor's Name: 3ab''i3 • ��13 Name Phone Number 3U Emai 1.8.10 9 0 APPENDIX E DESCRITION OF WORK c JY%SA-..Vt rj I[t s�6,7ksti1 ldat /Cr lam �dl 5F' PUBLIC NOTIFICATION PLAN 0 DATES OF CONS�t UCTION � l a��� HOURS OF CONSTRUCTION 7soo Ain - 7P HOW WILL EXCAVATED SOIL BE USED? ATTACHMEWS: Site Plan(s) Showing: L Construction Fencing 2. Emergency Vehicle Access 3. Construction Parking 4. Staging Areas S. Trailers, material storage, waste management, etc. 3q KIM Cp) IN'I1 1.8.10 FOUND #5 REBAR & PLATIC CAP L.S. #14111 m GRAPHIC SCALE 60 0 30 60 (IN FEET) S89°06'00"E 300 OPEN SPACE COO 0 0 O W N m 1 MTN EXISTING CONDITIONS/PARTIAL TOPOGRAPHICAL MAP OF: LOT 13, RUEDI SOUTH SHORE Architects A PARCEL OF LAND SITUATED IN THE SW 4 OF SECTION 14, TOWNSHIP 8 SOUTH, RANGE 84 WEST OF THE 6TH P.M. COUNTY OF PITKIN, STATE OF COLORADO SHEET 2 OF 2 UNITED STATES FOREST SERVICE 1162.70' OPEN SPACE BASIS OF BEARING 1573.41' 10.0' GENERAL PURPOSE UTILITY EASEMENT INSIDE ALL LOTS ALONG SOUTH SHORE DRIVE AND LAKE VIEW DRIVE AND LYING ADJACENT TO BOTH SIDES OF SAID DRIVE (SEE PLAT NOTE 3) CONSTUCTION EASEMENTS FOR PURPOSE OF ROAD REALIGNMENT SW55'09"E 835.07' ORIGINAL BUILDING ENVELOPEF LOT 13 SOUTH 543,490 SQ. FT. 12.477 ACRES 1 LOT 14 30.0' WIDE ROAD I RIGHT-OF-WAY GENERALPURPOSE UTILITY EASEMENT (SEE PLAT NOTE 2) 10.0' PROJECT BENCHMARK 543,490 SQ. FT. C 1/4 CORNER SEC. 14 FOUND 1963 BLM BRASS CAP \ ELEV. 8007.79' 380.41' REVISED ACTIVITY ENVELOPE REVISED ACTIVITY / ENVELOPE I I i I EDGd OF / GRAVEL ROAD rP) N88°55'09"W 418.01' LOT MILLER CREEK ESTATES z W w u z W O 1.4 Q W 7 H W H U o �CIO W Go W P4 O w DESIGN PHASE DRA, N: PATE: GI-ICKD MCF 3.18.13 MCF 5.1.13 DESIGN FSV. PHASE FNALS PHASE MCF 6.13.13 CO O O 0 O FROJECT: 13-00-1 50.0' OFFSET COPYRIGHTED BY MOUNTAIN ARCHITECTS. THIS LINE DRAWING IS NOTTO BE USED FOR MAKING ANY REPRODUCTION THEREOF, OR FOR CONTRACTING ANY BUILDING WITHOUT FIRST OBTAINING THE WRITTEN PERMISSION OF THE COPYRIGHT HOLDER, MOUNTAIN ARCHITECTS, DO NOT SCALE DRAWINGS MOUNTAIN ARCHITECTS IS NOT RESPONSIBLE FOR ERRORS DUE TO SCALED DRAWINGS REFER ANY QUESTIONS OR DISCREPANCIES TO MOUNTAIN ARCHITECTS BEFORE START OF CONSTRUCTION. i=REL IMINAR'r NOT FOR GONSTRUGT I ON SC,4LE: AS N07ED SITE 1 SHEET L10 9M SET NAIL AND LATHE ON PROPERTY LINE U1/ ELEVATION 5061.15' s ACTIVITY ° Cindy Houben, Director-3'—ENVELOPE / 2" i 1 I Clerk and Recorder's Certificate --- ----- This Ruedi South Shores Lot 13 site plan has been accepted for recording in the Office of the Clerk and ° Recorder Pitkin County, Colorado the __day ofI 2013 in Platbookatpage as I ------ ---- --- / -- - - Reception Number ACTNITY----_-- - --- °- -- a ENVELOPE �- 1 1 — ` /f , FOR LEACH ' FIELD Clerk an Recorder 8060 e�® nRAVEL ' ROAD ACTIVITY / *--- ---------� da / � ♦ / ENVE! FE d / PiROPOSED LEACH FIELD 5000 5.F. +/- - 1 GRAPHIC SCALE20 C 10 2 100 \ I .(IN FEET) —\ I T EXISTING COINDITIONS/PARTIAL TOPOGRAPHICAL MAP OF: LOT 13, RUEDI SOUTH SHORE �� a , 1 A PARCEL OF LAND SITUATED IN THE SW 4 OF SECTIOI�I 14, TOW 8 SOUTH, RANGE 84 WEST OF THE 6TH P.M. COUNTY OF PITKIN STATE OF COLORADO \ C ill J J 8070 / SHEET 2 OF 2 'JI A ° 0406] 5m' -o" OFFSET LINE / 8080 AA& MTN Arc itects DESIGN PHASE DRALN: DATE: CHCKD MCF 3.18.13 MCF 5.1.13 DESIGN REV. PHASE FINALS PHASE MCF 6.13.13 PROJECT: 13-001 COPYRIGHTED BY MOUNTAIN ARCHITECTS. THIS DRAWING IS NOT TO BE USED FOR MAKING ANY REPRODUCTION THEREOF, OR FOR CONTRACTING ANY BUILDING WITHOUT FIRST OBTAINING THE WRITTEN PERMISSION OF THE COPYRIGHT HOLDER, MOUNTAIN ARCHITECTS, DO NOT SCALE DRAWINGS. MOUNTAIN ARCHITECTS IS NOT RESPONSIBLE FOR ERRORS DUE TO SCALED DRAWINGS. REFER ANY QUESTIONS OR DISCREPANCIES TO MOUNTAIN ARCHITECTS BEFORE START OF CONSTRUCTION, PRELIMINARY NOT FOR CONSTRUCT I ON sCALI=: As NCTED SITE Z SHEET