Aspen/Pitkin Environmental Health Department
Permit for an Individual Sewage Disposal System
130 S. Galena St. Aspen, Colorado 81611
Phone 970-920.5070 / FAX 970-920-5197
Permit # 99031 Parcel ID # 2467-344-00-010
Type of permit New( ) Repair( X) Addition to House( )
Name of Owner Scott & Sharon Keller
Street Address 1460 Snowmass Creek Rd
Property legal description
Size of lot 1.28 acres Total square footage of the 1,800
Water source private well
# of bedrooms in house 3 # of offices, lofts & similar sized rooms in house 0
Caretaker unit
# of bedrooms in caretaker unit
Designed for what # rooms (list)
Designed by
Total square footage of the caretaker unit
Three
Church & Assciates
# of offices, lofts & similar sized rooms in caretaker unit
Permit information
Mailing Address 4501 Wadsworth Boulevard, Wheat Ridge, CO 80033
Perc rate see engineers report Profile hole Depth to groundwater or bedrock 'assume 0 ft
Septic tank capacity need 1,000 minimum Absorption area see engineer design
Comments
Septic permit approved per compliance with the engineer design and specifications dated October 26 , 1999
The design is for a 1250 gallon, two compartment concrete tank with a pump in a biotube vault, and pressure
distributed to mounded sand filter beds.
`Design is based on groundwater being at ground level which was confirmed by EHD staff during site visit on May
26, 1999.
If groundwater will cause instability problems to the septic tank, the tank shall be anchored in a manner designed
and prroved by the engineer. Septic tank is to be tested for waterproofness.
Drainage from Snowmass Ck Rd is to be diverted away from drain fields.
The existing failed system must be pumped and properly abandoned. All contaminated soil must be removed.
Permit approved by: '%)A Date: ku q9
Plans and specifications of the pro sed individual sewage disposal system have been reviewed and are considered
satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin
County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was
issued unless system construction has commenced or an extension has been approved in writing by the Department.
As -built drawings must be Included with this permit before the final approval will be issued.
Installer:
Final inspection ap oval- JA d!4 Vh r w Date: S 9
ASPEN/PI ENVIRONMENTAL HEALTH DEP MENT
APPLICATIC�OR INDIVIDUAL SEWAGE DISPOSWSYSTEM
130 S. Galena St., Aspen Colorado 81611
Phone 970-920-5070/Fax 970-920-5039
Name of OWNER AID Sr7 nI k6LLE/L
Owner's Mailing Address 10 6 -5A1owY,,5s (o
Business Phone: Home Phone: �Z
l -Z -A-
Primary Contact Person (all communication regarding this permit will go through this person)
Name {30 E�Csefl)
Company 07 ,1AI-5 /
Contact Mailing Address 6 tLAG E cc� 9 b .J
Business Phone: 723-3Zij Cell Phone : Fax : 92- 3 - 2 7
Parcel ID # (available from assessor's office
at 920-5160 or at www.aspen.comlassessor4 2 1n�_ -� - / - 0 L9 - O L 2
Street address of property H/0
Legal Description: �. " v`
Size of lot: .L, 2LO acres. Type of proposed structure: 414TiA4&ze of bldg. envelope: /Joy'A��L/LABrc
Total square feet of !souse 0 # of bedrooms in house 3
# of offices, lofts & similar sized rooms in house /t% �-
Caretaker Unit: Apched ( ) Detached ( ) Total area(sq. ft.) of caretaker unit 2
# of bedrooms) in caretaker unit # of offices, lofts and similar size rooms of caretaker unit
Permit is for: New Home ( ) Repair due to failure Remodel/Addition. ( ) Emergency use ( )
Water: Private well( \'](/\) Spring ( ) Stream ( ) Community/Public Water System ( )
If community system: Narl+e of system
The fee for a ISDS application is $330 for a permit that takes 6 hours or less for the department to approve. If approval takes
longer than 6 hours, a rate of $55 per hour will be charged. The maximum fee is $1000. The basic fee of $330 is due at the time
of application. The remainder, if any, will be due in two stages: first, at the time of issuance of the ISDS permit; second, before
final approval of the ISDS permit.
Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information is true and
accurate and that I have provided true and accurate information on locations of all existing and proposed wells, contour
intervals, buildings, property lines, ditches, slopes, watedines, springs, suction or irrigation lines, drinking water cisterns, drain
tiles, irrigation ditches, lakes, water courses, streams, floodplains, dry gulches, and existing septic systems. I hereby certify
that any such features not shown on attached site map are not present. Issuance of the permit does not imply the approval of
any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all
approvals and permits have been obtained.
The Aspen/Pitkin Environmental Health Department, Pitkin County and employees of these agencies will be held harmless
should the individual sewage disposal system fail or malfunction. The permit to construct is issued on information submitted by
the applicant or his/her representatives. The owner assumes full responsibility in case of failure of the system.
Signature of applicant //04W1/SIZk Date
Received by
Receipt #
Date
� �g y
•
•
�.
y .... 'e
�fuF.^.Js
�� Y.
y r _..
t _
.a..� '�ci'-'h.
���`.: �y
�a�
(<,
�' �` .
-_ I rg . — __ ._` �-
��
Y �" fi
��/ i}I„
�: �. Jf�� \\\\
�-'Y_ '-tiV�L _� '.i..,A A�
.. *.� y �
a
11
• 9
ten / Pitkin Environmental Health Departot
Contact Log Sheet
Name: J
Parcel ID* Address:
Date Person Spoken To Comments / Action to be Taken Initials
?.d 6 F- l .G
I
V
f i
CHURCH & Associates, Inc.
ENGINEERS & GEOLOGISTS
June 29. 1999
Scott and Sharon Kellar
P.O. Box 36
Snowmass, Colorado 81654
Subject: OWS Observation, Existing Residence
1460 Snowmass Creek Road
Pitkin County, Colorado
Job No. 10080
Dear Mr. and Mrs. Kellar,
As requested, we observed the installation of the onsite wastewater system (OWS) for the subject
site on June 23, 1999. The system was designed under our Job No. 10080, dated October 26,
1998.
The existing system included a 1000 -gallon Cavitette Aeration treatment plant and a 250 SF
drain field in an unknown location. The current system was failing and has been abandoned.
The repair OWS was installed for a three-bedroom residence with 1800 SF of living area. The
system includes one 1250 -gallon two-compartment precast water -tight concrete septic tanks with
a pump in a biotube vault and two pressure distributed mounded sand filter chamber beds. Each
bed had four rows of seven chambers. A drain to intercept runoff from Snowmass Creek Road
was installed and daylights into Snowmass Creek.
The pump was in place and power was connected at the time of our observation. The observed
components of the OWS were installed in conformance with the plans and specifications.
If you have any questions concerning this project, or if we can be of further service, please call.
Very truly yours,
r
CHURCH &
Edward O. Church
EOC/trp
2 copies sent
DENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 80033 CASTLE ROCK 303.660.4358
303.463.9317 Fax: 303.463.9321 EVERGREEN 303.816.1455
/0
0 0
CHURCH & Associates. Inc.
ENGINEERS & GEOLOGISTS
October 26, 1998
Scott and Sharon Keller
P.O. Box 36
Snowmass, Colorado 81654
Subject: OWS Repair Design, Existing Residence
1460 Snowmass Creek Road
Pitkin County, Colorado
Job No. 10080
Dear Mr. and Mrs. Keller,
As requested by Bob Nelson of Nelson Environmental and wastewater
Solutions (NEWS), we prepared an Onsite Wastewater System (OWS) repair
design for the subject site. Subsurface conditions were investigated
by NEWS to determine design parameters for the OWS design.
SITE CONDITIONS - The site is a 1.28 acre site in Pitkin County,
Colorado. There is an existing residence at the southeastern portion
of the lot. The slope at the proposed field is less than 5% to the
northeast. There is a sparse cover of grasses at the proposed field
location. The southeast property borders Capitol Creek and the east
property boundary borders Snowmass Creek. The west property boundary
borders the Snowmass Creek Road Right-of-way and a drainage ditch. We
understand the drainage ditch has water year round. The west property
boundary has approximately 10 feet of fill from the road. The proposed
field area is in a horse corral. Several fences are located in the
area which will need to be removed for installation of the OWS.
The site is served water by an Infiltration Gallery which collects
water from Snowmass Creek. The site is served by an existing OWS.
The OWS consist of a 1000 gallon Cavitette Aeration treatment plant
and a 250 square feet (SF) drain field of unknown location. The OWS
was installed in the early 1970's. The aeration plant was used for a
drain field area reduction according to NEWS. We understand the system
is currently failing as indicated by effluent backflow into the septic
tank after pumping.
EXISTING CONSTRUCTION - The existing residence has three bedrooms and
approximately 1800 SF of living area. The sewage load is 450 gallons
per day (GPD) using the Pitkin County standard of 75 gallons per day
per person with two people per bedroom and three bedrooms. Sewage
loading with a 1.75 peaking factor is 788 GPD. This loading includes
a garbage grinder, dish washer, and washing machine.
SUBSURFACE CONDITIONS - A subsurface investigation was performed by
NEWS. Subsurface conditions were investigated by observing one profile
pit and attempting to perform three percolation tests. Subsurface con-
ditions reported in the profile pit consisted of a 1 foot fill layer,
DENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 80033 CASTLE ROCK 303.660.4358
303.463.9317 Fax: 303A63.9321 EVERGREEN 303.816.1455
• ,,
2
ir
underlain by silt loam to an estimat depth of 6.5 feet underlain by
shale to the maximum depth explore of 6.5 feet. Ground water was
encountered in the profile pit at 3 feet. Ground water was encountered
in percolation holes at depths of 1 to 3 feet. Percolation test were
not performed due to the presence of shallow ground water.
RECOMMENDATIONS - We recommend a septic tank, pump, and pressure
distributed mounded sand filter chamber -bed OWS be installed at the
location presented on Fig. 1. The OWS design is based on an average
sewage load of 450 GPD and a sand filter application rate of 0.95
gallons per day per square foot. The drain field area could not be
calculated on an average percolation rate due to percolation test not
being performed. A percolation rate was back -calculated from the soil
.? absorptive area after the system was sized by the above criteria. The
back-naiculated e� rcolation rate is 191 MPI. We believe this percola-
tion rate exceeds the actual percolation rate of the soils onsite. The
drainage ditch near Snowmass Creek Road should be lined with a 10 MIL
PVC liner, where the drainage ditch is within 50 feet of the drainage
fields. We understand you would prefer to line the drainage ditch to
intercept runoff from Snowmass Creek Road.
We recommend thexistingaeration plant ba__abandoned and crushed
inplace or filled with a sandy material. The aeration plant should be
abandoned and not pose any structural problems to the existing shed.
The aeration plant should be abandoned due to its construction and
age. The existing drain field should be abandoned due to the Aspen/
Pitkin County Environmental Health Department (APCEHD) concerns with
drain fields 20 years old and it's unknown location and size.
We recommend the installation of one water -tight, 1250 -gallon, two-
compartment, precast concrete, septic tank with a pump in a biotube
vault. The septic tank should be installed greater than the distance
of the aeration plant to the stream, approximately 35 feet. Current
regulations indicate the separation distance a minimum of 50 feet. We
prefer to install the septic tank relatively shallow due to ground
water and the effluent pumping system. The septic tank can be located
greater than or equal to 35 feet due to the repair situation. At
least 1.5 feet of cover is required over the septic tank due to
buoyancy from ground water. We should be contacted to confirm fill
over the tank when a septic tank supplier is chosen. The septic tank
must be waterproof.
We recommend the installation of two pressure distributed mounded sand
filter chamber beds. Each bed should have four rows of seven chambers.
The drain fields must be located 50 feet from the streams and 100 feet
from the Infiltration Gallery. The OWS should be constructed similar
to Figs. 1 through 3.
The proposed OWS is designed for a three bedroom residencewit 1800
SF of living area. If additional bedrooms are anticipated, ecom-
mend the installation of a larger OWS to accommodate any "bui -out"
of the residence. The septic tank would have to be increased 328
gallons for each additional bedroom. Each additional bedro m will
require 273 SF of chamber bed or 18 chambers.
0 9
3
OPERATION AND MAINTENANCE - The owner must realize an OWS is different
from a public sewer system. The owner must be aware of and assume
responsibility for maintenance of the system. We recommend the septic
tank be pumped and filter be cleaned (hosed off) every two years. We
recommend performing maintenance during the late fall and early winter
due to ground water and concerns with buoyancy. Buoyancy is a concern
when the septic tank is empty during high water conditions. There are
daily considerations such as not putting plastic or nonbiodegradable
materials down the septic system. Water use must be monitored so
toilets are not allowed to run, when seals malfunction. To illustrate
the point, it should be noted a running toilet will consume in excess
of 1000 GPD if allowed to run. An excess 1000 gallon loading will
flood and irreparably harm the system.
LIMITATIONS - Our layout, design and recommendations are based on data
submitted. If subsurface conditions different from those described in
this report are encountered, we should be called to observe the sub-
surface conditions. If proposed construction is changed, we should be
notified to evaluate the affect of the changes on the proposed system.
All construction is to be in accordance with APCEHD ISDS regulations.
Pipe type and size, burial requirements, septic tank construction, and
other specifications, which are not depicted in our report, are to
conform to the requirements of the ISDS regulations. The installer of
the system must be familiar with APCEHD regulations, and is to have
demonstrated a knowledge of the ISDS regulations and requirements.
The OWS design includes one installation observation. Additional
observations are not included in the cost of this design. If there
are any questions or if were of further service, please call.
p ZPQ0 EG
psi
.CHURCH & ASSOCIATES, I 0. C
13172
9QEdward O. Church, P.E t116 z L
EOC/cbs
1 copy sent with Statement for Professional Services
cc: NEWS, 3 copies sent
IQ
TYPICAL PLAN VIEW
n
u
GRAVELESS CHAMBER
0.25' HOLE —
IN BOTTOM OF
END OF PIPE
TYPICAL CROSS-SECTION
FILL SLOPE
OF ROAD BACKFILL
DRAINAGE SWALE /
NATURAL
GRAVELESS
2' SCHEDULE 40 —
PVC MANIFOLD: LINES
FED PERPINDICULAR
3' OR 4" SCHEDULE 35
PVC OBSERVATION/
VENT PIPE
El
NOTES I. ELEVATION DIFFERENCE BETWEEN FIELDS
SHOULD BE LESS THAN 18 INCHES,
JOB NO. 10020
I i3
1.25' SCHEDULE 40
PVC PIPE HUNG ACCORDING
TO MANUFACTURER
SPECIFICATIONS! 1/8 INCH HOLES
FACED UP EVERY 5 FEET
3' OR 4' SCHEDULE 40 PVC
OBSERVATION/VENT PIPE
— 12
SAND FLTER MATERIAL
' CONCRETE SAND'
O.6 MM ( 10% Cu L4
21'
1.25' SCHEDULE 40
PVC PIPE HUNG ACCORDING
TO MANUFACTURER
SPECIFICATIONS 1/8 INCH HOLES
FACED UP EVERY 5 FEET
BACKFILL
MIN.
\\
54
2' SCHEDULE 40
PVC PUMP LINE
6.25'
3'
EXTENT OF SAND FILTER
MATERIAL
APPROXIMATE TOE OF FILL SLOPE
CALCULATIONS AND SPECIFICATIONS
25 DESIGN CRITERIA
STRUCTURE - 3 BEDROOM RESIDENCE
- 2000 SF
LOADING - 75 GPD PER PERSON
TOTAL LOADING - 0 • 450 GPD
PERCOLATION RATE T - NO TEST PERFORMED
DUE TO GROUND WATER
g' SAND APPLICATION RATE - R - 0.95 GAL/DAY/SF
AREA - (1.75 X O)/R
TOTAL AREA 829 SF )✓
BED SFECIFICATIONS
SAND MOUND INFILTRATIVE AREA - 434 SF/FIELD
WIDTH - 4 CHAMBERS. 12 FEET
LENGTH - 7 CHAMBERS. 43.75 FEET
TOTAL AREA - 2 FIELDS X 434 SF/ FIELD - 868 SF
TREAMENT UNIT SPECIFICATIONS
PROPOSED DRAIN FIELD DETAILS
SOL ABSORPTION AREA - 1089 SF/FIELD
SEE ABOVE FOR DIMENSIONS
AREA MEASURED BY DIGITIZING CAD DRAWING
TOTAL AREA 2 FIELDS X 1089 SF/FIELD - 2178 SF `✓
BACKCALCULATED PERCOLATION RATE - 191 MPI t, -
TOTAL
TOTAL CAPACITY - L75 X 0 X (30 HOURS/24 HOURS) - 984 GALLONS
RECOMMEDATION -1250 GALLON TWO COMPARTMENT PRECAST CONCRETE SEPTIC TANK
WITH A PUMP N A BIOTUBE VAULT
FIG. 2
�C 1460 SNOWMASS CREEK ROAD SCALE
PITKIN COUNTY. COLORADO 1 " = 40
1250 TWO COMPARTMENT PRECAST
\ \ CONCRETE SEPTIC TAN( WITH A
APPROXIMATE PUMP N A BIOTUBE VAULT IN THE
-y \ SECOND CHAMBER
,p LOCATIONC-) EXISTING
OF \
STABLE
P�
APPROXIMATE
I' CONTOURS 1�y 60'
TOE OF SAND FILTER
PROFILE
PIT 1 1 0 TOE OF FILL SLOPE
EXISTING SI -ED
TWO PRESSURE DISTRIBUTED AND CAVITETTE
CHAMBER BEDS 4• SCHEDULE 35
EACH BED - PVC PIPE TO BE
12' X 43.75' ' CONNECTED TO
4 ROWS OF 7 CHAMBERS
20 2' SCHEDULE 40 EXIST NG \ EXISTING SEWER
PVC PIPE RESIDENCE LINE
10' MN.
I 3
�4 150'
APPROXIMATE LOCATION Fly�r y'\ �2Cfi
OF DRAINAGE DITCH TO BE \
LINED. 10' M. BETWEEN
DRAINAGE DITCH AND EXISTING
DRAIN FIELDS ` \ • NFLTRAT
\ GALLERY
NOTES
1. LOCATION OF PERCOLATION AND PROFILE
HOLES ARE APPROXIMATE.
2. A CLEANOUT BETWEEN SEPTIC TANK AND
RESIDENCE SHOULD BE INSTALLED F ONE
DOES NOT EXIST. \oma
3. EXISTING OWS SHOULD BE ABANDONED DUE
TO AGE, CONSTRUCTION. AND PROXIMITY TO
STREAM.
4. DRAIN FELD MUST BE A MINIMUM OF 100
FEET TO THE INFILTRATIVE GALLERY AND
50 FEET TO STREAM.
5. SEPTIC TANK LOCATION IS PROPOSED
APPROXIMATELY 40 FEET FROM STREAM.
THIS IS GREATER THAN THE DISTANCE
BETWEEN THE AREATION UNIT AND STREAM
OF 35 FEET. APPROXIMATELY.
6. FILL ON TOP OF THE DRAIN FELD
SHOULD BLEND INTO FILL FROM SNOWMASS
CREEK ROAD WHERE ON PROPERTY. DRAINAGE
FROM SNOWMASS CREEK ROAD SHOULD BE
DIRECTED AWAY FROM DRAIN FIELDS.
7. SEPTIC TANK MUST BE WATERPROOF.
RECOMMEND SEPTIC TANK BE TESTED
FOR WATERPROOFNESS PRIOR TO
DELIVERY.
LOCATION OF PROPOSED OWS
JOB NO. 10080 RG. I
Is
i
CHURCH & ASSOCIATES, INC.
Effluent Pumping System
Notes: 1. Audible/Visual Alarm In building. Alar Level 3 Inches Above
On Float Level Of Tank To Be Installed On Dedicated Circuit.
2. One 1250 Gallon Two Compartment Precast Concrete
Septic Tank, Fiberglass Gasketed Lid with
3. Risers to surface: two Stainless Steel Baits
Conduit Seal SB4 PVC
PVC Riser with Grommets
Conduit to Splice Box ono an
Slope Ground (bond tadaptertank with
Away from Riser Control Panel recommended adhesive)
r_ _...._.._
................... — __.SIRO._EX__..__ ................................ .. _...
PVC Splice Box with Cord Grips
l Height Varies
Discharge Assembly
18' Minimum ? Flexible Hose
i Effluent Discharge
Inlet Tee
~, Tank Adapter (cast or bolted)
Aj0rmLiouid el Level Control Float
Assembly MFEPR
On/Off Redundant Off W/Alarm
i Check Valve (optional)
ul Vault Inlet Ports
JJJII��' Flow Inducer
1/8' Weep
Hale Effluent Pump
i
Filter Cartridge
1 t ....
Drain Port
Siotube® Pump Vault
SVT1248-24EFl
Disclosure: The owners of E.O. Church, Inc. also own S.C.G.
Enterprises, Inc. which distributes Orenco Systems Inc. products
Patents 1 4,439,323 a 5,492,635
Foreign Patents Pending
O 1997, Orenco Systems, Inc.
,.. 111:4
O8
Orenco Systems®
Inmrpnramd
Rev
EDW—TD-3
1.0 (2/98)
Fig. 3
•
•
C1
CHURCH & ASSOCIATES, INC. 10/22/98
Pump Selection for Pressurized System
PROJECT: Job No. 10080
0
Orifice Size
Residual Head at Last Orifice
Lateral Length
Total Number of Laterals per Cell
Orifice Spacing
Valve Model (# of Zones)
Lift to Manifold
Discharge Assembly Size
Transport Line Size
Pipe Class/Schedule
Transport Length
Manifold Size
Pipe Class/Schedule
Length of Distribution Header
Lateral Size
Pipe Class/Schedule
Flow Meter
'Add-on' Friction Losses
0.125
inches
feet
feet
feet
feet
inches
inches
feet
inches
feet
inches
feet
5.00
44
8
5.00
1
20
1.25
2.00
40
100
2.00
40
18.00
1.25
40
none
0.00
Calculation
Minimum Flow Rate per Orifice
0.43 gpm
Number of Orifices per Zone
72
Total Actual Flow Rate
31.2 gpm
Number of Laterals per Zone
8
Total Dynamic Head:
0.0 feet
Lift to Manifold
20.0 feet
Residual Head at Last Orifice
5.0 feet
Frictional Head Losses:
Head Loss in Transport Pipe
1.7 feet
Loss through Discharge Assembly
4.9 feet
Head Loss in Distribution Header
0.1 feet
Head Loss in Laterals
0.0 feet
'Add-on' Friction Losses
0.0 feet
ad Loss through Distributing Valve
0.0 feet None Used
Head Loss through Flow Meter
0.0 feet None Used
Size Pump for:
TOTAL FLOW RATE 31.2 gpm
TOTAL DYNAMIC HEAD 31.7 feet
None used
None used
I /(,
/, JOB NO. 10080 PUMP SPECIFICATIONS TABLE 1
ASPEN/PITK• NVIRONMENTAL HEALTH DEPARTME9
ISDS DESIGN REQUIREMENTS -DEPARTMENT USE ONLY
Name Keller
House Size 11"
800 %( (75 gpd, 100 gpd, or 130 gpd) 75
#of Bedrooms, Similar Rooms acces ' e to baths in Main Residence 3
# of Bedrooms, similar rooms w/ ess to bath in ATTACHED caretaker
# of Bedrooms & Similar Room / access to baths in DETTACHED caretaker
Average Daily Waste Flow 450 # bedrooms X 2 people/br X 75
State Review Required?- no
Perc Rate / 28 (T),) 3 equals # of Perc Holes Required
Design Flo w (Q) = If bedrooms X 2 people/bedroom X gpd X 1.75
Q= 787.5 /
Minimum tank capacity 984 gallons
,Qs�'go
.Z i
Absorption Area (A= Q/5 X SQRT) 3 3
A = 833 sq. ft. of absorption area required X q
54 infiltrator units without reduction ( (o
A maximum 30% reduction is allowed for use of deep gravel or gravelless chambered system.-? q R 3
583 sq.ft. with reduction 9 j
38 infiltrator units with reduction
AREA NEEDED FOR STANDARD ABSORPTION TRENCHES
278 833 Total sq ft /3 =lineal ft of trench needed
5 278 lineal ft/assumed trench length of 60ft = # of 60ft trenches needed
4 # trenches minus 1 = rows of 6ft wide undisturbed soil between trenches
15 5 times 3 = total width of of 60" long field needed for just the trenches
24 4 times 6' = total width of 60' long field needed just for undisturbed soil
39 width of trench +width of undisturbed soil = total width needed
39 by 60 ft is the area needed for a standard absorption field in a trench configuration with no
reductions taken and ASSUMING AN AVERAGE PERCOLATION RATE OF 28
SLOWER PERCOLATING SOILS WOULD REQUIRE MORE AREA.
SETBACK FROM WELL SETBACK FROM POND, STREAM OR IRRIGATION DITCH
# of feet = 100 # of feet = 50
SETBACK FROM DRY GULCH
# of feet = 25
Remember: 8 feet of additional distance for each 100 gallons/day of design flow over 1,000 gallons/day
should be added unless an RPE can verify that it is not necessary to prevent contamination.
1/20/99
/�4 Printed on Recycled Paper
ASPEN/PITKENVIRONMENTAL HEALTH DEPARTM
SDS DESIGN REQUIREMENTS-DEPARTMENT USE ONLY
Name Keller
House Size 1,800 175 gpd, 100 gpd, or 130 gpd)
#of Bedrooms, Similar Rooms ac ssible to baths in Main Residence
# of Bedrooms, similar rooms VIEccess to bath in ATTACHED caretaker
# of Bedrooms & Similar Roo s w/ access to baths in DETTACHED caretaker
Average Daily Waste Flow 450 # bedrooms X 2 people/br X 75
State Review Re uired? no
Perc Rate 191 (T) 3 equals # of Perc Holes Required
Design Flo w (Q) = # bedrooms X 2 people/bedroom X gpd X 1.75
Q= 787.5
Minimum tank capacity 984 gallons
Absorption Area (A= Q/5 X SQRT)
A = 2177 sq. ft. of absorption area required V
140 infiltrator units without reduction
A maximum 30% reduction is allowed for use of deep gravel or gravelless chambered system.
1524 sq.ft. with reduction
98 infiltrator units with reduction
AREA NEEDED FOR STANDARD ABSORPTION TRENCHES
726 2177 Total sq ft /3 =lineal ft of trench needed
75
3
13 726 lineal ft/assumed trench length of 60ft = If of 60ft trenches needed
12 # trenches minus 1 = rows of 6ft wide undisturbed soil between trenches
39 13 times 3 = total width of of 60" long field needed for just the trenches
72 12 times 6' = total width of 60' long field needed just for undisturbed soil
111 width of trench +width of undisturbed soil = total width needed
111 by 60 ft is the area needed for a standard absorption field in a trench configuration with no
reductions taken and ASSUMING AN AVERAGE PERCOLATION RATE OF 191
SLOWER PERCOLATING SOILS WOULD REQUIRE MORE AREA.
SETBACK FROM WELL SETBACK FROM POND, STREAM OR IRRIGATION DITCH
# of feet = 100 # of feet = 50
SETBACK FROM DRY GULCH
# of feet = 25
Remember: 8 feet of additional distance for each 100 gallons/day of design flow over 1,000 gallons/day
should be added unless an RPE can verify that it is not necessary to prevent contamination.
1/20/99
/ !, Printed on Recycled Paper
KEcc�R HaUSE
7GT 62 SEcrio�/ 9V o �
e-flguTN ^TINGE FII "S%
19
0 0
Engineers Submittal for Septic Permit in Pitkin County
Owners Last Name: KELLER Location: 1460 SNOWMASS CREEK ROAD
Summary of information regarding new septic system:
Type of system being proposed: SEPTIC TANK AND PRESSURE DISTRIBUTED MOUNDED
CHAMBER SAND FILTER BED
Other treatment processes being used: NONE
Does the system use any mechanical parts? (Prohibited unless there is no alternative)YES
If yes, explain why there are no alternatives A PUMP IS REQUIRED DUE TO ELEVATION
DIFFERENCE FROM SEPTIC TANKS TO DRAIN FIELDS
Does the system require any maintenance other than routine pumping? YES
If yes, who will do the maintenance? CLEAN FILTER WHEN SEPTIC TANKS ARE PUMPED
Are any reductions being proposed? NO
If yes, what makes the lot and soli conditions optimal?
Which of the following are on the site or within setbacks?
Closest distance of septic system to each feature
[] 100 year floodplain
40 FEET. APPROXIMATELY
[] well(s)
100 FEFf
[] irrigation ditches
>10 FEET
[] streams
50 FEET
[] ponds
N/A
[] other features
N/A
What was the profile hole depth? 6_5'
What is the depth to groundwater? OBSERVED AT 1 TO 3 BELOW GRADE
What is the depth to bedrock? 6_5'
What assumptions, if any, were made in system sizing and design? (Include any local, site-
specific data, such as months without snow cover, ratio of evaporation to absorption, etc. that
are relevant.)SAND FILTER APPLICATION RATE OF 0.95 GALLONS PER DAY PER SQUARE
FOOT AND PERCOLATION RATE OF NATURAL SOILS OF 191 MINUTES PER INCH.
If there are any variations from normal design, please explain how they can be demonstrated to
improve treatment and protect water quality. NONE
ASPEN/PITKIN ENVIRONMENTAL HEALTH DEPARTMENT
ISI&ESIGN CALCULATIONS .
Owner's Name KELLER —'-Parcel ID #
House Size (sq. ft.) <2000 , , (75 gpd, 100 gpd, or 130 gpd) 75
Number of Bedrooms in Main House 3
Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House 0
Number of Bedrooms in Dolached Caretaker unit ' 0
Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit 0
(If the caretaker unit is ATTACHED, treat as if part of main house.)
Average Daily Waste Flow 450
State Review Required? no
Perc Rate 5EE RPT.=- (T)
Design Flow (Q) _ # potential bedrooms X 2 people/bedroom X gpd X 1.75
Q= 788
Absorption Area (A= Q/5 X SQRT)
A = SEE RPT. sq. ft. of absorption area required
SEE RPT. infiltrator units without reduction
A maximum 30% reduction Is allowed for use of deep gravel or gravelless chambered system,
only if the lot size and Boil conditions are optimal.
If a reduction is being proposed, describe why lot size and soil conditions are optimal:
A= N/A sq.ft. with reduction
N/A infiltrator units with reduction
Type of system: []Absorption trenches []Absorption lred [X] Gravelless chambers
[]Dry well []Seepage Pit [X]Other PRESSURE DISTRIBUTED MOUNDED
SAND FILTER
Minimum tank capacity 984 gallons
SETBACK FROM WELL
# of feet = 100
SETBACK FROM POND, STREAM OR IRRIGATION DITCH
# of feet - 50
SETBACK FROM DRY GULCH
# of feet = 25
FINAL INSPECTION BY:
y
DATE:
-
r�24k
REVOCABLE
Permit Fee is $165.
ROW PERMIT
Paid $�Q_S Permit -1.
Pitkin County Public Works
PLEASE READ ATTACHED
INSTRUCTIONS
BEFORE COMPLETION
76 Service Center Road
Aspen, Colorado 81611
(970) 920.5390
Fax: (970) 920-5374
THIS PERMIT MUST BE REPT ON SITE AT ALL TIMES
wall
Type of work: Fence
; LandscapingOther_ SS/T« FH.D
, *Ve to DIED3
Property Owner
Applicant Name OWAJ64
Address—Po 36 SatJc)MASS��b �ba D
Leaal Description of Propert*1to be Served: TijGT �z
Property is a: Corner Lot 4,_
Inside Lot
Does the structure(s) currently exist? 5
Proposed date for beginning construction:
at cached plans showing the proposed structures(s), encroachment
cnto public right-of-way, property line(s), sidewalks, curbs,
intakes, hydrants, meters, manholes, irrigation ditches or
structures, existing fences, or any other affected appurtenance in
the project area (to scale and dimension) and sections, as well as
evaluations (if Applicable).
In consideration of the issuance of a revocable permit for the
structure(s) above indicateri, applicant agrees as follca:s:
1That permit hbasisucande(si are herein are restricted authorizedoft
rrevocable
to the land
described.
2. That the permit is limited specifically to the type or
structure(s) described on the application.
134
® n�anw
anaio...a
I
3
all work, materials and equipment time utilid to remove same.
If applicant refuses to pay these costs, Pitkin county has the
rigst the
perty
allhcostsmofean removal assessment
the same manner asogeneralntcollect
taxes are
collected. maintenance, including
8. That the applicant agrees to perform any
landscape maintenance to the structure(s) and its associated
impacts on the right-of-way.
9. That the applicant has read and understands all of the termE
and conditions set forth in this application.
10. Special Conditions:
ILAlt,.A�
ignature of Property owner
(If joint ownership, both signatures)
Approval:
a
So
Date
o
Date
THIS PERMIT MUST BE KEPT ON SITE AT ALL TIMES
136
J
Y w Mr•
low
.01
N,
- i ISE-/r� •`� 3 ' .... - - N :� 3S
;,: nvl..,tuwfx
PR.a`6rlwpj 1 : c!t ••!fir t', - "4-._-.` ,
`_ �• n. �y
_ _ _ � Si. . ' � �\ . c.•��p ar'eL�w p��MQA L.n--"'• � -.
-
-- ,ttRvcrat�* r±K?l[lyTli
/ . . � As.. i edsct¢�, tetvnr ccrs..n.t , '•Y r•
°'a � /.. / ' \\ xutunew ovlrn i. xnc M•n ++ i�,' t- • i
' - •. �•�_• — ,�`• % I Y 1 ..... " �- S,Ru•:.i.s�q{ tal aTorri t. rt .Y' t>` s• -
_l� i 1 1 ! •: , X40 ..KA��FD M TT V
•�•" ;�' .. C - ^_� _ - ' - 2u P Q -%i / :` _':` j '.� • \ 4Ar - -- TN A ohs 9Toav n
^rr�ro
tef. -•l[+crir,
•%nc•°a �naVioraTw�'L_t`,7 �.•es:'t':� .
�' , .' ' � :r�� /i - -.. � _` • . _.-.y�...r.i \. �12 f - m.r-•x- r. n:t/ . _uxY: _. _ �
ti
,� %VOTE: �o OT//E,LSTA�6AM-S �,Q/n/c�5;'- IUcL•�S SUcs/oq/C/�
G✓MEQ—%dli� It/�e 6/Sidf.& :Bll/LD/�"s (R�ICA:Tt0n1D
V11 r
W,- WACES eY 0006F.
s.Avereo mt�•: ;. -, :: - Tom: e::a.^:�r+r
TRI -CO Management, Inc. OWTED �!, ,,., .;.� .:. TK/�CT CZ, 5M 94
Box 1730 FE` GOA T65, R 66 W
Aspen, Colorado 81611
- - — M4ODF.OFCP
M
Nelson Environmental Wastewater Solutions, ZtA •
E November 13, 1998
W
Pitkin County Board of Adjustment
S c/o Joanna Schaffner, Zoning Officer
City of Aspen
130 South Galena St.
Aspen, CO 81611
Re: Board of Adjustment Variance Request for a Replacement Septic System on the R.
Scott Keller Property at 1460 Snowmass Creek Road (A tract of land in Tract 62, Section
34, Township 8 South, Range 86 West of the 6d' P. M., Pitkin County, Colorado)
Dear Board of Adjustment Members,
The enclosed application is a request to construct a site-specific, engineered type of
onsite wastewater treatment system for the referenced property. Although there are no
changes to the existing buildings on the lot, the proposed engineering design involves
placement of fill during construction. The proposed replacement onsite wastewater
system also involves locating the final treatment and infiltrative area of the system
adjacent to the County road and constructing a mound over thirty (30") in height.
Because of the type of planned sewage system needed, we understand that a variance
from the board is necessary.
Currently the existing residence is served by an antiquated, inoperative aerated treatment
plant and poorly functioning absorption trench system that, on occasion, has failed. The
tank aerator unit no longer works and the metal tank of this part of the system has
become badly corroded. The absorption area of the septic system has become clogged
after 26 years of use. Despite frequent pumping, occasionally the black, odorous tank
effluent surfaces near the creek. The existing sewage system is in violation of county
regulations and is in need of replacement before winter sets in.
Because of the difficult site conditions, high ground water table, and the proximity to the
creek and water supply, the Aspen/Pitkin Environmental Health requirements have
necessitated design of an engineered mound to mitigate and minimize any pollution
potential from a new, replacement system. This is one of the few design options
available to this applicant to meet all of the county setback requirements contained in the
Pitkin County Individual Sewage Disposal Regulation. These setbacks include providing
proper separations from the stream and the drinking water source. There is also an
important requirement for a four -foot vertical separation from the bottom of the effluent
absorption area to the high seasonal ground water table that must be met.
It will impossible for the applicant to comply with all of the permit requirements of the
Health Department without a variance. The hardship for continued enjoyment of the
residential property without replacing the septic system with a properly designed sewage
system is evident.
P.O. Box 6961 Snowmass Village, CO 81615 Office (970) 923.3289 Home & Fax (970) 923.2766
Board of Adjustment Vace Request for a Replacement Septid*tem
11/15/98
Page 2
There are several facts to consider in deliberating on this variance request.
1) The mound will not be visible from Snow -mass Creek Road on any
adjacent property. It is actually below the road embankment by about
eight feet and will be feathered into this excavated cut of the original
road construction.
2) The two properties to the South of this residence have very similar
engineered mound systems, which required no variance at the time of
their construction. These systems perform adequately and in
compliance with all county requirements.
3) The Aspen/Pitkin County Environmental Health Department supports
the proposed engineering design. We have received every indication
that a permit will be issued to begin construction of the replacement
septic system, once this variance request is approved.
We hope that this application demonstrates the hardship and need for this variance in
order to construct the proposed septic system as soon as possible. Thank you for your
consideration of this matter. We will be available to answer any of your questions at the
next meeting.
Sincerely, e4v,�Z—
Robert
F. Nelson, R.E.H.S.
Representing Scott Keller
cc: Church and Associates, Inc. — Engineers and Geologists
M
• PITKIN COUNTY •
BOARD OF ADJUSTYIENT
Application Form
DATE
REPRESENTATIVE 0013
MAILING ADDRESS tl' . V
OWNER e. CorrC-
MAILING ADDRESS
LOCATION OF PROP
A TAar ,N heck, -1),
CASE 4
PHONEZ3 -.3,ZSq
Any pertinent data must accompany this application, and will be made part of this Case.
application if it does not contain all the facts in question.
J
Owner's or Representative's Signature
(To be completed by the Zoning Department)
O cF � rp
The Board may return [hiss
Provisions of the zoning resolution requiring the Zoning Official to forward this application to the Board of
Adjustment, and reasons for not granting a building permit
Rem!estino.
' Front Yard Setback Variance, where ' is required.
' Rear Yard Setback Variance, where ' is required.
Side Yard Setback Variance, where' is required.
Side Yard Setback Variance, where' is required.
'Height Variance, where ' is allowed.
Square Feet where a rnwdmum of _sq. 1 is allowed.
Other.
Application filed
Date of Meeting
Notices Mailed
@�z
Zoning Official
Parcel ID No.
Secretary
Zone District
T n Ci79
Z/J
Z
FAW
0 0
Nelson Environmental & Wastewater Solutions, Ltd
E November 13, 1998
W
Pitkin County Board of Adjustment
S c/o Joanna Schaffner, Zoning Officer
City of Aspen
130 South Galena St.
Aspen, CO 81611
Re: Board of Adjustment Variance Request for a Replacement Septic System on the R.
Scott Keller Property at 1460 Snowmass Creek Road (A tract of land in Tract 62, Section
34, Township 8 South, Range 86 West of the Oh P. M., Pitkin County, Colorado)
Dear Joanna,
I have reviewed all of the documents included in the application to the Pitkin County
Board of Adjustment to file for a request for a variance to construct a site-specific,
engineered type of onsite wastewater treatment system for my property. I am aware of
and have no objections to the variance request, as submitted.
My representative will be available to answer any of your questions at the next meeting.
Sincerely,
Scott Keller
cc: Church and Associates, Inc. — Engineers and Geologists
P.O. Box 6961 Snowmass Village, CO 81615 Office (970) 923.3289 Home & Fax (970) 923.2766
0 0
Board of Adjustment Application for R. Scott Keller
Adjacent Property Owners
Parcel ID #2647-334-00-009
OBJ, LLC
P. 0. Drawer 2030
Glenwood Springs, CO 81602
Parcel ID #2647-334-00-013
Colorado Moonlight, Inc.
P. 0. Drawer 2030
Glenwood Springs, CO 81602
Parcel ID #2647-343-00-081
Ralph L. and Cheryl S. Braden
610 E. Hyman Ave.
Aspen, CO 81601
Parcel ID #2647-344-00-002
TRC, LLC
P. 0. Drawer 2030
Glenwood Springs, CO 81602
Parcel ID 92647-342-17-003
Mark K. and Karen M. Johnson
P. 0. Box 555
Snowmass, CO 81654
Parcel ID #2647-341-18-009
Douglas T. and Lynda Robson Weiser
3240 Marry St.
Miami, Florida 33133
Parcel ID #2647-344-00-012
Henry A. Young and Rachel F. Dayton
1469 Snowmass Creek Road
Snowmass, CO 81654
Parcel 11) #2647-344-00-015
Kathleen Ann DeWolfe
P. 0. Box 253
Snowmass, CO 81654
0�
0
�,q T85k ed
C� celb� -3yy .fobIG
PITKIN COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH
Box V Asper. City Hall
Aspen, Colorado
925-2020
PER14IT ='
System Location
Contractor "
1. Construction approval:
Plans and location are hereby approved.
Perc. rate / inches in /p minutes= /6 S- sq. feet of
tion area per bedroom.
/6"f- X / sq. feet = /63' 6q, feet minimum require-
ment. I Suggest
Date y/o?�/�'/ Inspector
2. Final approval of system:
No system shall be deemed to be in compliance with the
Sewage Disposal Laws until the assembled system is approved
prior to covering any part.
8" septic tank cleanout with gas seal
F/ Proper materials and assembly
1 4-'l Adeouate absorption area
Adequate concrete cover (dry wells only)
Date Inspector •�--i "��GG -
*Retain with permit records at construction site.
If at any time this system fails a new permit must be obtained and
�/ ` repairs made immediately.
00LORADO STATE DEPARTMENT OF PUBLIC HEALTH
Water Pollution Control Commission
4210 East 11th Avenue
Denver, Colorado 80220
J. 2c'.Q o
z'�-IAMONT KINKADF.
C C4 ENVIRONS' ENTAL HEALtn
Box V
Aspen, Colofado 81611
K
APPLICATION FOR APPROVAL OF LOCATION FOR SEPTIC TANK SYSTEMS
Applicant (Owner):
Mail Address: //Q /� �[ City-
,
A. INFORMATION REGARDING PROJECT SUBMITTED FOR REVIEW:
Phone:ya-;/7,?
(Attach separate sheets or report showing entire area with respect to surrounding
areas, topography of area, habitable buildings, location of potable water wells,
soil percolation test holes, soil profiles in test holes.)
I. Location of Facility: County City or Town
Legal DescriptionG y;�,„ ' —-Lot size: r, i!,F QrfbGai —
2. Type of area and facility - Number of persons to be served:
Subdivision Motel Restaurant Trailer Court
Other
3. Source of domestic water: Public(name):
Private: Well_ Depth Other Depth to First Ground Water Table
4. Is facility within boundaries of City or Sanitation District:_ i &,
If so, name --
5. Distance to nearest sewer system:
Have negotiations been attempted with owner to connect:
If rejected, give reason:`
6. Rate of absorption in test holes in mi nu s per inch of,dryp in water level after
holes have been soaked for 24 hours:
7. Name, address & telephone of person whoo)a0"' ptiI t_e"stsV
8. Name, a`ddddresss� & telephone
of person res�p7on/siib�legfor design of they system: %.V--(35z�
Ll .J
9. Est. bid opening date:
Est. Completion date: Est. Project Cost:
APPOL-L1TE SYSTE4 LOCATION- Give donees in feet'
a`i-�F
Type of system applied for dimensions to be
filled in upon permit issuance.
Septic & Bed
_.,..__ gal.
--- I1" Top Soil
4" Straw
To Septic - 6"1" Gravel
4" Gravel
!" t
._,-A Septic & Yordak
Septic
�,...,,.=- is _.-•-- - -----� I.'�`
depth i.•..__._.._ ___,
t `t
i.. Scaled Holding
?oq
ID Septic & Dry Well(s)
1 Mechanical +
1" Gravel
Cender Block
2" Gravel
8" dean out h
Concrete ccver
Dimensions
Bed
Dry Well
Holding pond
Chlorinated dis.
Septic Tank
---- See Page 16 ofSewage Disposal Systems
)_ ] Pit Privy
L
1 33
LAMONT KINKADE
J •
COLORADO STATE DEPARTMENT OF PUBLIC HEALTH ENVIRONMENTAL HEALidBOX V
Water Pollution Control Commission Aspen, CDlorado81611
4210 East 11th Avenue
Denver, Colorado 80220
APPLICATION FOR APPROVAL OF LOCATION FOR SEPTIC TANK SYSTEMS
Applicant (Owner): Tnhn Robinson
Mail Address: P. 0. Box 2 City Snowmass Phone:
A. INFORMATION REGARDING PROJECT SUBMITTED FOR REVIEW:
(Attach separate sheets or report showing entire area with respect to surrounding
areas, topography of area, habitable buildings, location of potable water wells,
soil percolation test holes, soil profiles in test holes.)
I. Location of Facility: County Pitkin City or Town
Legal Description Lot size:
2. Type of area and facility - Number of persons to be served:
Subdivision Motel Restaurant Trailer Court
Other: residential
3• Source of
domestic
water: Public(name):
Private:
Well x
Depth Other
Depth to First Ground Water Table
4. Is facility within boundaries of City or Sanitation District: no
If so, name:
5• Distance to nearest sewer system: 4 miles
Have negotiations been attempted with owner to connect: no
If rejected, give reason:
6. Rate of absorption in test holes in minutes per inch of drop in water level after
holes have been soaked for 24 hours: ExtremeltDoroue ground conditions. Absorption
test not practical.
7. Name, address & telephone of person who made soil absorption tests:
8. Name, address & telephone of person responsible for design of the system:
S. L. DODSON ENGINEERED PRODUCTS, Box 248 Glenwood Springs Colorado 81601
9. Est. bid opening date: none Est. Completion date: Est. Project Cost:
Date:
Signature of Owner
Page 2
B. COMMENTS OF LOCAL GOVERNMENT AND SIGNATURES:
10 -
Check one:E]Mayor or City Manager EfHealth Department (City or
County) ❑ County Commissioners
Comments:
Signature E Title
Note: The applicant must obtain the comments and signature of at least one
of the above.
C. FOLLOWING FOR STATE HEALTH DEPARTMENT USE:
D. ACTION BY COLORADO WATER POLLUTION CONTROL COMMISSION:
Sy WP-10(Rev.11-68-100),
i
i
945-6346
Ic..
# 0
S. L. DODSON ENGINEERED PRODUCTS
P. O. BOX 248
GLENWOOD SPRINGS, COLO. 81601
April 22, 1971
John Robinson
P. 0. Box 2
Snowmass, Colorado 81654
Dear John,
I have filled out the application of location
for the septic tank systems. I have been instructed
by Mr. Kinkade's office to forward this form to you.
You are to request Mr. Kinkade to come and inspect your
system and improve it on the site.
He will then take the application form and your
$25.00 check after inspection of the site.
SLD/mgd
3�
Sincerely,
SLD
MATERIALS AND EOUIPMEN T:
WATERSUPPLY
SEWAGE DISPOSAL AND
LIFT STATIONS
IRRIGAT IDN AND DRAINAGE
CULVERTS AND BRIDGES
S. L. DODSON ENGINEERED PRODUCTS
S. L. Dodson,
President
DECLARATION OF COVENANTS •
Page 2
IN WITNESS WHEREOF, the undersigned owner(s) has/have executed this
Declaration of Covenants as of the�day of 19
--OWNER(S)--
STATE OF COLORADO
AND COUNTY OF
The foregoing Declaration of Covenants was executed befo
day of �c;iu . 19�, by
as owners
Witness my hand and official seal.
My commission expires:
w- l --'1(-j
ss.
u
me this
Notary Public
Approved this day of , 19 . This approval subject to
withdrawal if the foregoing Dec aration o ovenants is not recorded within
sixty (60) days of this Approval.
COLORADO WATER POLLUTION CONTROL COMMISSION
By
Technical Secretary
WP -30(1-71-40)
CCi0RAD0 DEPARTMENT OF EALTH
Water Pollution Control Commission
4210 East 11th Avenue
Denver, Colorado 80220
DECLARATION OF COVENANTS
KNOW ALL MEN BY THESE PRESENTS, THAT:
WHEREAS, the COLORADO WATER POLLUTION CONTROL COMMISSION HAS approved
the following described land, situate in the
of and State of Colorado, to -wit:
TJ—escribe entire parcel to be served by septic tank)
as a location for a septic tank, as defined by the Colorado Water Pollution Control
Act of 1966, as amended, for the treatment of domestic sewage on a temporary basis.
NOW, THEREFORE, in consideration of the approval of the above described
land as a location for a septic tank, the undersigned, as the owner(s) of said land
does/do hereby declare that the following covenants shall be and constitute cove-
nants running with said land:
1. When the Colorado Water Pollution Control Commission determines that
a community or municipal disposal system is available and can provide service to
the above described land, the septic tank located upon said land will be abandoned
and wastes from the described lands will be carried to the available community or
municipal disposal system and the owner of the above described land shall bear the
entire cost of constructing and installing any sewerage system necessary to carry
such wastes to the available community or municipal disposal system.
2. If at any time hereafter, the septic tank shall adversely affect the
quality of the waters of this State, the owner of the above described land shall
use such other sewage disposal system as will maintain the quality of the waters
of this State within the limits set by the applicable water quality standards
adopted, from time to time, by the Colorado Water Pollution Control Commission.
3. This Declaration of Covenants shall be binding upon the undersigned
and the heirs, personal representatives, successors and assigns of the undersigned.
(Continued on reverse side)
y
P
I
T
I
N
C
0
V
N
T
Y
30
Office of Envirooptal Health
506 E. MAIN STREET
Mr. C. M. Clark
P.O. Box 566
Aspen, CO 81611
•
ASPEN, COLORADO 81611
November 23, 1976
Re: John K. Robinson Residence
A parcel of land in Section 34, Township 8 South,
Range 86 West of the 6th P.M. Known and numbered as
1460 Capitol Creek Road
Dear Mr. Clark:
An inspection of the sewage disposal system for the above captioned
property was conducted by this writer on November 23, 1976.
The sewage system consists of a 1000 gallon Cavitette aed
treatment plant and a seepage bed of approximately are feet.
This system was installed and approved on April 28, 1971, and
appeared to be functioning adequately at the time of inspection.
A copy of the permit records is attached.
If you have any further questions, please feel free to call me at
925-4366.
RFN:
Enclosure
SrQly,�"�A
r
Robert F. Nelson, R.P.S.
County Sanitarian