Loading...
HomeMy WebLinkAboutpitkin.eh.247323200037 (1990)Document Layout (From Most Recent to Oldest Permit) Permit Application Log Sheet/Notes & Photos Communications As -built Design Engineer Design Soil Information Water Permit & Information Second System on property Third System .etc. Floor Plans Please See Building and Land Use Approvals Files for additional information. ASPEN♦PITKIN ENVIRONMENTAL HEALTH DEPARTMENT INDIVIDUAL SEWAGE DISPOSAL PERMIT NO.� 9 O�3H TYPE OF PERMIT: (A Initial Construction ( )hmrgoncy Use 1 )Repair work,(Pievious Permit 1 .) ! )Alteration of an existing system, or installation (Previous Permit 1 ,) ( )Use Permit as a result of Sale 1 )Othori ISSUED TO: DATE OF ISSUE Owner A71i4-P- Home PhonegZ3-&133 Business Phone ?!ailing Address PdI (brg La•Z6Z �'byunlA.65 kh1_ I"f CD Wl111'� Ma il.ing Address Sewage Disposal System Work to be performed by _IT n x 6+ory- This permit valid only for premises location by the following! legaldescriptiont* N Nw�J 4t7 Z"Jy ) ?!7 3 L.)f St1E Z•5 Q-t(t5 NATER SUPPLY Pr! i(O- C Wc,l1 AVERAr..E PERCOLATION RATE This J -,- This Individual Sewage Disposal Permit is granted with regard to the following us*: -5* 6"l(,'. Rvabor of, Dodreoms I Lofts I Garbage Disposals D Dishwashers_ Clothes Washers '1�_. CALCULATED AVERAGE DAILY WASTE LOAD Z-1 5- GALLONS?VIII,-k low �Ibvv w�1.1)nq VUtRivu THE NATURE OF THE SYSGT,L':f INCLUDED UNDER THIS PERMIT: 'owL) b tend �1 I.t..+-� . rypa of Tank or Treatment Units ltPtA C AtIL Tank Capacity 11 b _ _Callon Minimum method of final Disposals EvA.poTrArlsPira, on *_8AbsorptioD Area 12 5D square Fect minimum _ Deacription (including brand name, if any) of other equipment or•appurtnsncess p4jon uAcr On t'T &-J (i hX+11- 6 4o�A- low - Flow W"t r nv.4w 4-o 1,z_; v) tsi9ul.cd on liotA X +o a tasu.rd a.&KAJ MLS - ,,c S� .Other Conditions or Speciattonst I`o irlbtallt aetor,Cidlo� to �1ar15 arid 51aci�icat,on5 of ScYlr)uusal', (5`'"`„ a �a�Fcd 8 0. r S�STA �REQUIRINGl w -S �lovv IO XB THE HHEALTH DEPARTMENT e 5 OFI 1 LC �/ O W✓ll tom, 1 )Refere Excavation (Upon completion of excavation and prior to plsGement of gravel 4)O Defoce rnvering distribution L ,n,rr .L. �Isy-s Item of nb,s,fforptien field Prior to backfill of anIy!component (Other, Specify) torriel_•[+l. W (k i V15AA-1LIt_.1 Orn UrAI iLQ,_r Plans and specifications of the proposed sewage disposal syntem have berm—reviewed and are eonstflered satisfactory. Pernlsaton is hereby granted GI tin,, Owner or his agent to perform the work indicated above in accordance with the Pitkin County Individual Srca;c Ulspesal Revnlatiom in etfm:t on the d.,te of issue. In addition to general pravistens set :orth on Lu. .everae Letaei, this Permit is subject to the following additional terns and conditions! . APPROVED FOR ISSUE BYC / Aspen/Pitkin Environmental ✓�. -� (title) Health Officiar TI•.r ahove tmtividual sewage disposal system Sn3talled by iwra b, en la q.: cte(l 1.)r usery a raper ac ntat the r.( tins Alpe.. i'tt an Liv .n.. etJL ticalcincncy.,rtm. tic. T1,.• .mons',awme arl rwctwn;.ULILLy in case of failure or load yvacy of th v sC,u di Oa 1 ayatem. COrplrto as-LullL drawing attached. DATE OF FINAL INSPECTION-wa�_ - ' Aspen/Pitkin Environmental BY: ( � �L �NGt� M /,Q��,(,Tt /I.kJ TITLE Health Officer /op G 130 South Galena Street Aspen, Colorado 616'li 30W920-5070 .kms N RpPr�xiwtR.-k Scale. I"=10' T f /ri' � I y rx'k+a I PSC • k vv,' 3f ? �CkanV14-+ +0.12C in U- i (A li oaz�) I Z5o q6t) I on Conor-ek �Cpt+e-iank � I I � I I I �- V � �T ('xd W14 3oml 4YPaI on I I rle rr and 0!14- washed �a nd tFf< 64ve cvapo-f-MA5- P' ia.fa o� at2� i I �swaLe, Z' VeVH- p Ipe Name of Address 0 ASPEN40PITKIN • ENVIRONMENTAL HEALTH DEPARTMENT APPLICATION FOR AN INDIVIDUAL SEWAGE DISPOSAL -PERMIT OWNER -rt p� '��- A, S06A�V PHONE 90-S-6 133 of OWNER MA /6l5 Name of APPLICANT N:;ez0celcL Q. ! ),N',,4 ", PHONE 9a3-6133 PERMIT TO a ly)Picked UP ( )Nailed tot TYPE OF PERMITS At Installation ( )Repair ( )Owner ( )Applicant . 1 )Emergency use ( )Alteration NOT due to failure LOCATION OP PROPOSED SYSTEMS Legal Description SEq,- Block Filing Subdivision Sire of Lot TYPE OF STRUCTURE, lole Family Dwelling ( )Others Do you plan any further,ddltlons to the /\ residence? ( )YES NO Mo. of bedrooms_ No. of Lofts_L No. of Garbage Disposals -' O — Ro: of Automatic Dishwashers \ No. of Automatic Clothes Mashers 1 MATER SUPPLYs �y,,ti►rivats Mall, Depth NOT 14.NDW or ( )Public, Name of System I )Spring • ( )Stream or Creek TYPES OF INDIVIDUAL SENACE DISPOSAL SYSTEM PROPOSEDS ' "ptic Tank/Absorption Plaid ( )Aeration Plant/Absorption Field ( )Composting Toilet ( )Incineratlen Toilet ( ):bund ( )Recycling, potable use ( )Reeyclinq, other use ( )vault Privy ( )Others The 'initial site inspection must be arranged with the Aspen/Pitkin Environmental Health Department (925-2020, 8:30-9:30 a.m.) before • permit can be Issued. The individual savage disposal perait must be issued before • building permit can be obtained. FIRM. INSPECTION APPROVAL MUST BE GIVEN BY THE ASPEM/PITAIN ENVIRONMENTAL HEALTH DEPARTMENT PRIOR TO BACKFILLING ANY PORTION OF THE SYSTEM. Application for an individual avaga disposal permit is hereby submitted. The undersigned acknowledges that the above Information IS true and that false info ti n vi Fl Invall at th application and any subsequent it signature of Applicant {,/ DATE / ( bis application becomes. inval 3 a the from the above date.] NOTE: 'PLOT PLAN must be filed with this application Please locate the following items by measured distances: 1. Property lines and dimensions. 2. Proposed and existing water wells on subject property and adjacent property. 3. Domestic water service lines. 4. Proposed and existing buildings, driveways, and other • structures. S. Streams, lakes, ponds, irrigation ditches, and other water courses. 6. Proposed and existing individual sewage systems on subject property. SUBMIT A REVISED PLOT PLAN PRIOR TO CONSTRUCTION IF INSTALLATION IS TO BE CHANGED FROM ORIGINAL PLAN. The undersigned hereby acknowledges receipt o this Individual swage disposal perm a 1 tion and a mit fee in the amount of T �-�CJV op Receipt Number , Data fee Received �.by t'l� Adminli native Officer 3 130 South Galena Street Aspen, Colorado 81691 303/82"070 2g. E @NVELOP 1 30' 0" SETBACK • Ow ' rQ7 197.67• _ r @NVELOP 1 30' 0" SETBACK • Ow ' rQ7 197.67• PITKIN COUNTY ENVIRONMENTAL HEALTH Field Test Data Sheet on Percolation Test PROPERTY OWNERLdt[nA(.ic YID - PHONE MAILING ADDRESS LEGAL DESCRIPTION OF PROPERTY 5L /1f If- NW X19 6� 5z3 TM, 03 V-1 LOCATION OF TEST HOLES Three (3) test holes required per system � L �Si- n� Yui Y) _ K'n� •^U4 WA Test Hole Depths (24" minimum) nL+ 4 f�-� Diameter of Test Holes Water remaining after 8 hour soak TEST HOLE No.1 TEST HOLE No. 2 TEST HOLE No. 3— Drop 3- DropTime Drop Time Drop Time Percolation Rate Each Hole Average Rate Comments on soil r site:, z �I i ^U�1 �¢I _ I i1_ j ✓�r��� lv Signature T Date EDGE OF EXISTING ROAD 50' LAKE SETBACK LINE •� • PROPERTY LINE 10' PROPERTY LINE SETBACK LINE 50' LAKE SETBACK LINE TOP F BED_9.33 - PROP. CONTOUR BOTTOM OF BED= 9 - _ EDGE OF EXIST. ROAD 9 9 DISTRIBUTION LINES 98 r- i (Typ.) OUTSIDE EDGE OF PROPERTY LINE SWALE TO DAYbw AIR VENT OUTSIDE Er OF BED - � � � � - � � � \- � � \ j = = \ i TBP OE BED=99.33 \ \_ BOTTOMZ7 -BED = 97.50 1OO - L _ AIR VENT INV DIST. PIPE=9 58 B S O' F CLEAN OUT DIA. PVC (ASTM03 344 \ FOOT SLOPE \ 700 i AT TEL -=98.68_ BUILDING E/✓VEL OPE BOTTOM OF SWAL HEADER PIPE 00 120' BUILDING SETBACK LINE - \ ,�• 100 750 GALLON N�E. SEE BED PLAN FOR PROPOSED CABIN DE f �R P/NG SCHEDULE \ COBE SEPTIC TANK AND B D/MEASr9�llNG OTTOM O� W =98.88 \ \ 4" D PVC -(ASTM 3034) \ l ® 1/4" PER fC767­ SLOPE (751% C4LCULATED�F_\ _ \ \ \ \33.84' R,/N)) 5 O h 7 10' PROPERTY LINE SETBACK lNE \ N . 0,TEE = 10 1. 22 J JO \ \ \ \ \ \ l 4" DIA TM 3034) SLEEVED CLEANNU� \ \ l ` IN CAS g1FE ® 1/4'%FT. SLOPE \ \ \ \ \ INV. OUT = 102E \ \ / NOTE: LOCATE CLEAN OUT /N UTILITY ROOM \ \ \ BU/L&(NG ENVELOPE \ l / INV. OUT = 101.561 / \ \ IV�E. FIELD AND TANK LOLg4T(O MAY \ \BE FT€LD ADJUSTED TO BEST F17 E l \ SITE ALONG AS SET BACK RE IREMECVTS \ \ \ -,,,ARE MET \ \ \ NNE, FIBERGb45'S SEPTIC TANK MAY BE \ \ SUBSTV,JTED FOR WNCRETE, HOWEVER, THE l / \ \FOCL0WLED�R /NSTAS MUST BE LLAT704� TONACCOMMOD47 \ THE MGH GRO WATER COVIT/ONS. (IE., \ 154NK MUS`T�BE P ERL Y RESTRAINED AGAINST FLN-TAT/ON ASR AND�DUR/NG INSTALLATION AND \ l \ OPERA ft1, \ \ \ \ ' - _/ jOs \\ \ AC 770 4' P �\ \\ \ �� 45 WYE LAP LINER 1' - - EX/SANG GRADE � \ 2:1 SLOPE � RNISHED GRADE PROVIDE SWALE TO DIVERT - RUN -OFF AROUND E. T BED 3' 5 24' _ SANDY TOPSOIL VARIES - - - - - - 6" A7 CENTER ZfpOM TO 2" AT EDGES 7" WASHED SAND LINER BOTTOM OF BED TO BE-/ CONSTRUCTED /N NATURAL GROUND, BELOW TOPSOIL x200' L�- 4" PERFORATED PVC SLOPE 0%FT (TYP.) BOTTOM OF BED SHALL BE LEVEL 0. 1't, SCARIFY BEFORE PLACING ROCK SECTION A A SCALE 10= 3' 53.00' 2.00' 4" PERFORATED PVC SLOPE O'%FT. (TYP.) trrAIR VENT (2 REQLD)- - - - - §TE DETAIL 3' v_� MIRAR FABRIC OR 4" OF STRAW ,-2:1 SLOPE - LAP LINER 1' LINER 13" OF 1/2" TO 2 -112 - CLEAN ROCK �o - ry 4" PVC FROM � SEPTIC TANK 4" SOLID WALL PVC EVAPO- TRANSPIRA TION BED DETAIL SLOPE 0""/FT. SCALE 10= 10' 4" TEE, DO NOT GLUE 4" AIR VENT 0 N PLUG SANDY TOPSOIL VARIES FROM 6" AT CENTER TO 2" AT EDGES SEED TOPSOIL - 45 W E1BOW 7 r� FLOW \ \ FLOW TO - ILjljt FROM DESIGN CALCULATIONS: \ TANK OUSEPTIC (OR TO TANK) 1. NUMBER OF BEDROOMS=1.5 � FILL D) _ NUMBER OF PERSONS/BEDROOM=2 _ CLEAN-OUT DETAIL 75 GALLONS/PERSON/DAY / d I /l �w 107 _� - Q= 1.5x2 ,75=225 GPO PLS l N V 2. FOR 1 BEDROOM HOUSE, PROVIDE 1-750 GALLON SEP77C TANK DEPTH TO GROUND WATER 1'-2' PERCOLAAON RATE= (GREATER THAN 60 MPI) LOADING RATE= USE 0.135 GALLONS/SF/D14Y .i J. REVISE AVERAGE DAILY FLOW FOR LOW USE WATER FIXTURES. 0=225-(25)225= 168.75 GPD 4. TO MINIMIZE CONFLICT WITH GROUNDWATER AND FACILITATE' NO PERCOLATION, PROVIDE AN EVAPO-TRANSPIRATION (LINED) TYPE SYSTEM. A= (Q)/L. R. A= (168.75)/0.135= 1250.00 SF LENGTH= 53.00 FT. PROVIDE 1 BED 53' LONG x 24' WIDE SCALE: 1"=10' GENERAL NOTES: 1. ALL MATERIALS, INSTALLATION PRACTICES, SETBACK REOUIREMENTS, ETC., SHALL COMPLY WITH THE P/TK/N COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS. 2. THE ET BED SHALL BE CONSTRUCTED SO THAT THE BOTTOM /S LEVEL t/-0. 1'. PLACE BED IN NATURAL GROUND; NO PORTION OF THE BED SHALL BE PLACED IN FILL. 3 PROVIDE ADEQUATE SURFACE & SUBSURFACE WATER DIVERSION TO ASSURE 7HAT RUN-OFF DOES NOT ENTER THE EVAPO-TRANSPIRATION BED. IF SUBSURFACE WATER /S ENCOUNTERED, NOTIFY ENGINEER. 4. STONE SHALL BE 1/2" TO 2 1/2" SCREENED ROCK. 5. SAND SHALL BE 0.5 TO 1.0 MM EFFECTIVE SIZE WITH A UNIFORMITY COEFFICIENT OF 4 OR LESS. PROVIDE SIEVE ANALYSIS TO ENGINEER FOR REVIEW. 6. THE RECOMMENDED BED SEEDING /S BLUE GRASS AT 4 TO 6 LBS/1000 SQ.FT. ALL 07HER AREAS DISTURBED BY CONSTRUCTION SHALL BE RESEEDED WITH NATIVE GRASSED TO PREVENT EROSION. 1- }` SAND STRATA M/RAF/ FABRIC ° CPO 4" PERFORATED PVC DISTRIBUTION PIPING ROCK MOUNDED e ABOVE PIPE PERFORATIONS OL ROCK STR4 TA ........................................._............................................................................................................... AIR VENT DETAIL SCALE- 1"= 1'-0" 7. THE LOCATION OF THE BED MAY BE ADJUSTED IN THE FIELD TO BETTER FIT THE SITE, PROVIDED ALL SETBACKS ARE MET 8, DRAIN HOLES /N 4" PERFORATED PIPE TO BE AT 30" SPACING (2 HOLES PER SPACING, 7/32" DIA. LOCATED DOWNWARD). (USE OF ASTM 2729 STANDARD LEACH FIELD PIPE ALLOWED.) 9. 4" PVC TEES SHOULD NOT BE GLUED TO ENABLE OBSERVATIONS OF WATER LEVEL IN SYSTEM AND TO REMOVE EXCESS SALTS ACCUMULATION OR SURPLUS WATER, IF NECESSARY. 70. USE RISERS AS NEEDED TO BRING SEPTIC TANK ACCESS HATCH WITHIN 6" OF FINISHED GRADE. 11. THE LINER SHALL BE PLACED IN A MANNER WHICH WILL PREVENT INJURY TO SCUFFING, PENETRATION BY FOREIGN OBJECTS OR DISTRESS FROM ROUGH SURFACES. 12. A HYPALON LINER WITH NO FIELD SPLICES /S SPECIFIED TO PROVIDE PROTECTION TO THE GROUNDWATER IN THE AREA. THE USE OF VISQUENE SHALL NOT BE ACCEPTED. FACTORY SPLICES ARE ACCEPTABLE. IF SPL/CES MUST BE MADE, MANUFACTURERS REP SHALL BE ON SITE TO MAKE SPLICE. BED LINER /N 1" OF SAND (TOP AND BOTTOM) 13 CAST IRON PIPE OR PIPE OF EQUAL STRENGTH OR OTHER PIPE PROPERLY SUPPORTED TO PREVENT FAILURE BY SETTLING SHALL EXTEND FROM TANK FOR A DISTANCE OF AT LEAST FIVE FEET (5) FROM THE INLET AND OU7LET ENDS. 14. 77 -IE CONTRACTOR AND OWNER SHALL TAKE WHATEVER MEASURES ARE NECESSARY TO ASSURE THAT (a) SEPTIC TANK AND SEWER LINES ARE COMPLETELY WATER TIGHT, AND (b) THE SYSTEM IS TO BE INSTALLED TO PREVENT FREEZING OF ALL PRESSURE AND GRAVITY SEWER LINES. 15. THE Pl1KIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT AND THE ENGINEER SHALL BE NOTIFIED WHEN CONSTRUCTION COMMENCES AND KEPT ABREAST OF THE CONSTRUCTION PROGRESS SO THAT SUFFICIENT INSPECTION CAN BE PERFORMED TO ASSURE CONFORMANCE WITH THESE PLANS. PROVIDE A MINIMUM OF 48 HOURS NOTICE TO EACH. 16. SITE PLAN SUPPLIED BY OWNER AND SUPPLEMENTED BY ENGINEER. OWNER AND CONTRACTOR TO VERIFY CONSTRUCTION PROPOSED WITH EXISTING CONDITIONS PROPOSED GRADES SHOULD BE VERIFIED WITH EXISTING SUCH THAT THE FIELD WILL NOT BE CONSTRUCTED IN FILL AND SUCH THAT TANK AND LINES ARE NOT ON THE SURFACE. Lp