Loading...
HomeMy WebLinkAboutpitkin.eh.247320100005 (2005)(Cabins C-2, C-3, C-9, C-13, C-8, C-1)Document Layout (From Most Recent to Oldest Permit) Permit Application Log Sheet/Notes & Photos Communications As -built Design Engineer Design Soil Information Water Permit & Information Second System on property Third System.etc. Floor Plans Please See Building and Land Use Approvals Files for additional information. PitWounty Environmental Health Depart Pe for an Individual Sewage Disposal m 0405 Castle Creek Road, Suite 10, Aspen, Colorado 8 i 611 Phone 970-920-5070 / FAX 970-920-5077 Permit# -95826 0 033 Parcel ID# 2473-201-00-005 Type of permit New Owner Connell Street Address 26640 Frying Pan Road Property legal description Size of lot 26.872 acres Addition/Remodel to F iv — Diamond J Ranch x ) REMODEL CABINS Total square footage of the house Water source Private well (pending non -community groundwater approval) # of bedrooms in house # of offices, lofts & similar sized rooms in house Caretaker unit # of bedrooms in caretaker unit Total square footage of the caretaker unit # of offices. lofts & similar sized rooms in caretaker unit Designed for what # rooms (list) 7 seasonal cabins — total of 11 bedrooms Permit information Designed by High Country Engineering, Jeff Odor Mailing Address 1517 Blake Avenue, Suite 101, Glenwood Springs, CO 80112 Perc rate 10 Profile hole depth 8 ft Depth to groundwater or bedrock Minimum Septic tank capacity See engineer design Minimum Absorption area Comments Greater than 8 It 852 so ft w/ 30% reduction Septic permit approved per compliance with the engineer design and specifications dated June 27, 2005 and June 30 memo regarding number and use of standard chamber units. Any changes must be approved by this department and the design engineer prior to them being made. Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin County ISDS regulations. Any area where a sewer line crosses a water line must be encased within 10 feet of the crossing. Setback from the ditch to the field must be at least 50 feet. Two tanks will feed into the system. Tank #3=2000 gallons and tank #4=1000 gallons. Tanks must be two compartment and have an effluent filter on the outlet. The field will consist of 55 Standard chambers a bed configuration as specified by the June 30 memo. A PVC liner must be installed to the north of the bed. See specifications in the July 6 and July 11, 2005 memos. This department does not endorse any brand of products. This permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an as -built letter to this department. This department must also be called for an inspection with a minimum of 48 hours advanced notice. `Revegetation over the area of the field is very important for the functioning of the system. Pitkin County has guidelines that must be followed to assure the plants that are introduced are appropriate for the conditions of the area. The use of native plants is strongly Permit approved by: Cb.4 (L� %l7(_(' Ca, Date: 7 405 Plans and specifications of the proposed individual sewage disposal system have been reviewed and are considered satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was issued unless system construction has commenced or an extension has been approved in writing by the Department. As -built drawings muse inc u e ith,this permit before the final approval will be issued. Installer: ITIS. I \/ Final approval: bean A'��R - Date: / I4 qC1 PITKIN C LINTY ENVIRONMENTAL HEALTH DEPARTMENT APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM 0405 Castle Creek Road, Suite 10, Aspen Colorado 81611 Phone (970) 920-5070 Fax (970) 920-5077 Name of OWNER Connell Development Company Owner's Mailing Address P.O. Box 541057 City, State, Zip Dallas, TX 75354-1057 Business Phone: (214) 357-4694 Home Phone: E-mail Address: the@conne11 companies. com Primary Contact Person (all communication regarding this permit will go through this person) Name Thomas H. Stewart Company Connell Development Company Contact Mailing Address P.O. Box 541057 City, State, Zip Dallas, TX 75354-1057 Business Phone: (214) 357-4694 Cell Phone: Fax: (214) 357-4953 coll at 9205160 or at www.oitkinassessor.ora I Building Permit # (if available) Street address of property see Legal Description: Lot _ Size of lot: 26.872 Total square feet of house Caretaker Unit: Attached ( 2 4 7 3_ 2 0 1 .0 0. 0 0 5 26604 Frying Pan Road I acres. ,Filing ,Subdivision Type of proposed structure: n/a # of bedrooms (potential) in house ) Detached ( ) (% bAi wS unit # of bedrooms (potential) in caretaker unit Permit is for. New Home ( ) Repair due to failure ( ) Remodel/Addition ( ) Emergency use ( ) Water. Private well ( X ) Spring ( ) Stream ( ) Community/Public Water System ( ) If community system: Name of system The fee for a ISDS application is $600 for a permit that takes 6 hours or less for the department to approve. If approval takes longer than 6 hours, a rate of $100 per hour will be charged. The maximum fee is $1000. The basic fee of $600 is due at the time of application. The remainder, if any, will be due in two stages: first, at the time of issuance of the ISDS permit, second, before final approval of the ISDS permit. Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information is true and accurate and that I have provided true and accurate information on locations of all existing and proposed wells, contour intervals, buildings, property lines, ditches, slopes, waterlines, springs, suction or irrigation lines, drinking water cisterns, drain tiles, irrigation ditches, lakes, water courses, streams, fioodplains, dry gulches, and existing septic systems. I hereby certify that any such features not shown on attached site map are not present. Issuance of the permit does not imply the approval of any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all approvals and permits have been obtained. The Pitkin County Environmental Health Departure ,Pitkin CoNnty and employees of these agencies will be held harmless should the individual sewage j lsystemor malfuncgdn. a permit to construe is issued on information submitted by the applicant or his/her repres. T er assu s fu ibility in se of failure of the system. Signature of applicant_ Date Received by (r?, Receipt # j I jo Q Date 511105 0 Pitki ounty Environmental Health Departm nt Pert r an Individual Sewage Disposal S 0405 tle Creek Road, Suite 10, Aspen, Colorado 11 Phone 970-920-5070 / FAX 970-920-5077 Permit # 05025 Parcel ID # 2473-201-00-005 Type of permit Connell Street Address 26640 F Property legal description Size of lot 26.872 acres Pan Road Addition/Remodel to F iv — Diamond J Ranch x ) REMODEL CABINS Total square footage of the house Water source Private well (pending non -community groundwater approval) # of bedrooms in house # of offices, lofts & similar sized rooms in house Caretaker unit # of bedrooms in caretaker unit Total squaJe footage of the caretaker unit # of offices, lofts & similar sized rooms in caretaker unit Designed for what # rooms (list) 11 seasonal cabins —total of 17 bedrooms Permit information Designed by Mailing Address Perc rate 18 1[41[47.171 1517 Blake Avenue, Suite 101, Glenwood Springs, CO 80112 1� Profile hole depth 6'/� ft Depth to or bedrock Groundwater at 5 feet Minimum Septic tank capacity See engineer design Minimum Absorption area 1262 sq ft w/ 50% reduction Septic permit approved per compliance with the engineer design and specifications dated March 15, 2005. Any changes must be approved by this department and the design engineer prior to them being made. Minimum horizontal distances between components tithe system and physical features shall conform to the Pitkin County ISDS regulations. Any area where a sewer line crosses a water line must be encased within 10 feet of the crossing. If the absorption field comes within 25 feet of any water lines they must also be encased. Prior to installation of the system, and S f of profile hole must be dug in the area of the proposed field to reconfirm depth to groundwater. This de rtment must be contacted to evaluate findings in the profile hole prior to installation of this system. Four to ks will feed into the system. Tank #2=2000 gallons, tank #3=1500 gallons, and tank#4 000 gallons. All tanks ust be two compartment and have an effluent filter on the outlet. The field will consist of 129 Quick 4 chambe in serial distribution as specified in design. There must be at least 6 feet of undisturbed soil etween each trench. This department does no endorse any brand of products. This permit must be kept on-site during installation. The engineer must do a fl al inspection of the installation and submit an as -built letter to this department. This department must also be called for an inspection with a minimum of 48 hours advanced notice. 'Revegetation over the area of the field is very important for the functioning of the system. Pitkin County has guidelines that must be followed to assure the plapts that are introduced are appropriate for the conditions of the area. The use of native plants is strongly Permit approved by: (IhLa P`7 (ndk . Date: D120 O Plans and specifications of the proposed individual sewage disposal system have been reviewed and are considered satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was issued unless system construction has commenced or an extension has been approved in writing by the Department. As -built drawings must be included with this permit before the final approval will be issued. Installer: Final approval: Date: Cl • • • PITKIN COUNTY ENVIRONMENTAL HEALTH & NATURAL RESOURCES DATE: 1119105 Send to: TOmn+ %�-vvGLr i - Fax Number. 1357-aq5 3 CC: &Qw CC Fax Number: From: cQr10 6I,oc (' Phone Number. q7t) C)Z0-543$ Number of Pages, Including Cover: oZ ❑ URGENT LJ REPLY ASAP ❑PLEASE COMMENT IIa PLtASE REVIEW ❑ FOR YOUR INFORMATION COMMENTS: Q6 -o' V�4t �a J. 3 4 � J fax cover Pitkin County Environmental Health and Natural Resources 0405 Castle Creek Road Suite 410, Aspen, CO 81611 Phonef970) 920.5070 1 Fax (970) 920.5077 el Web site www.aspenpitkin.com/depts/12/ ro Au&. 3. 2005 1:59PM HIGH COUNTRY ENGINEERING • CIVIL ENGINEERING To: TIM CASE FROM: JEFF ODOR DATE: &3-05 MEMORANDUM SUBJECT: DIAMOND J GUEST RANCH HCE PROJECT No: 2041709.00 No 2822 P. 2/3 • LAND SURVEYING Alan Rowe has brought to my attention that the piping configuration for the community cabin ISDS is installed different than as indicated on the plan. It is my understanding that the piping has been installed and connected in the following configuration: o Cabin 13, Cabin 8, and Cabin 1 will be tied together and convey the effluent to one septic tank. Based on the design sizes of these cabins, the tank for these cabins shall be a minimum of 1000 gallons (875 gallons required). This is determined based on a total of 4 bedrooms. o Cabin 9, Cabin 2, and Cabin 3 will be connected and convey the effluent to a second septic tank. Based on the design sizes of these cabins, this tank shall be a minimum of 1500 gallons (1313 gallons required). This is based on a total of 6 bedrooms. I also understand that the Cabin 5 relocation was unsuccessful, and Is not included in the new tank size. I have included a figure provided by Allen showing the rough layout of the reconfigured system. The size and shape of the absorption bed will not change with this reconfiguration. It is also important to maintain all setback requirements as defined by Pitkin County and CDPHE. HCE will need to verify that the required setbacks have been met. HCE will illustrate these changes, as found during the inspection, on the as -built drawings. Allen has also scheduled the inspection for the community cabin ISDS. The current plan is for HCE to be onsite in the afternoon on Thursday, August 4, 2005 for the inspection. 1517 BLAKE AVENUE, SUITE 10 1 GLENWOOD SPRINGS, CO 61601 970.946-8676• PHONE 970.9452888• FAX 4 wW W. HCENG.COM 141NVERNESS DRIVE EAST. SUrTE F-120 ENGLEWOOD, CO 80112 3039250544. PHONE 30-1,925-0547 -F" ""c `A,6 3 2005'� 1:59PVuf'HIGH COUNTRY ENGINEERING i s�o-sz�-sseo No 2322 P. 3/3 • �\ 1 Received Time Aus. 3. 1:12PM M Ju1.26 2005 7:56AM HIGH COUNTRY ENGINEERING • CIVIL ENGINEERING To: Tim CASE FROM: JEFF ODOR DATE: 7.26-05 SUBJECT: DIAMOND J GUEST RANCH HCE PROJECT NO: 2041709.00 No_2514 P. 2 E LAND SURVEYING This memo is a summary of a phone conversation I had with Allen Rowe yesterday (July 25,2005) regarding the community cabin ISDS. The location of the absorption field is somewhat flexible. When HCE survey crews were onsite and located the field, the location was based on Unknown information. The intention of the ISDS design is to locate the field in the general location of the profile pit and percolation test holes. This area is open enough to allow for construction without excavation in the hillside or significant damage to existing vegetation. Also, it has come to my attention that an active ditch exists west of the absorption field along part of the road before crossing the road and discharging to the ponds. In adjusting the location of the absorption field it is important to maintain required setbacks to the nearby waterways and ponds. This design requires 98 feet to the waterways and ponds. The PVC liner shown on the existing plan allows for a reduction to this setback, however a minimum of 50 feet must be maintained. As discussed in an earlier memo, the bottom of the PVC liner must be as low or lower than the waterway or pond within 98 feet of the absorption bed. Please feel free to contact me with any questions you may have. 1 517 BLAKE AVENUE, SUITE 10 1 GLENWOOD SPRINGS, CO 81601 97094541676.►HONF 9709442555•FAX CI W W W.HCEHG.Com 141NVERNESS DRIVE EAST, SUITE F420 ENGLEWOOD. CO 601 12 3039250544• PHONE 3039250547.FAx Jun.30. 2005 9 20AM HIGH COUNTRY CIVIL ENGINEERING TO: CARLA BLOCK ENGINEERING MEMORANDUM FROM: JEFF ODOR, HIGH COUNTRY ENGINEERING DATE: 6.30-05 SUBJECT: DIAMOND J GUE$f RANCH HCE PROJECT No: 2041709.00 ND -1754 P 2/6 0 LAND SURVEYING RED,IE9VRD JUN L 8 2005 EPITKIN COUNT,( NVIRONh;ENTAL HEALTH I am taking this opportunity to address the number and type of infiltrators to be used for the Ventura and Cabin Community ISDS's. The design submitted for each system specified the Infiltrator System Quick 4 infiltration unit. I am proposing the use of a standard infiltrator utut manufactured by Infiltrator Systems, the standard BioDiffuser Chamber manufactured by ADS, or other equivalent product. These infiltrator units have an infiltration area of 15.5 sf per unit associated with it. By using these infiltration units the total number of units will decrease from the proposed design, however in both designs the total required area will not change. The following discussion refers to standard infiltrator units as any of the approved equivalent products available. The Ventura Cabin has a required infiltration area of2320 sf This is based on a design flow of 2275 gpd and a percolation rate of 26 min/inch. Since infiltrators are being used in a bed configuration, a 30% reduction in area is allowed resulting in a required area of 1624 sf. Each standard infiltrator unit allows for an area of 15.5 sf This results in a required 105 standard infiltrator units, It is my recommendation that these units and installed In the same configuration as the illustrated design (signed 6-27-05). The only difference between the illustrated design and the infiltrator units being proposed here is the number of units per row. The proposed design decreases the number of units per row from I I Quick 4 infiltrator units to 7 standard infiltrator units. The footprint of the previous layout using the Quick 4 15178"w AVENUE,su1TE lol GLENW v SPRINGS, CO a 1601 9708458676. PHONE 8769452555. F" I�; W W W.HCCNG.COM 14 INVERNE DRIVE EAST, 9u1r6 F-120 ENG WOOD. CO 80112 30;9250644. PHONE 303-9250547.P" Jun 30 2005 9 21AM HIG0H COUNTRY ENGINEERING 0 No 1754 P 3/6 infiltrator unit had a bed dimension of 44' long (11 units) and 45' wide (15 units). Utilizing the standard infiltrator units, the footprint dimensions are 43.75' long (7 units) and 45' wide (15 units). The Cabin Community 1SDS proposes a required infil tion area of 1217 sf based on a design Slow of 1925 gpd and a percolation rate of 20 min/inch. As with the Ventura Cabin, infiltrators are being proposed in a bed configuration allowing for a 30% reduction in required area. This results in a required area of 852 sf. Using the standard infiltrator units having 15.5 sf per unit allowed, a total number of 55 standard infiltrator units are required. The current design indicates 4 rows of 22 Quick 4 infiltrator units having a footprint of 12' wide by 88' long. As the total number of infiltrator units has changed, the detailed layout ^lam may be altered. The design of the system has not changed and will remain an equilateral / distribution system with manifold piping at each end However, the absorption bed configuration may consist of 4 rows of 14 resulting in 56 standard infiltrator units or if the topography allows 5 rows of 1 lunits may be installed resulting in 55 standard infiltrator units. If 4 rows of the standard infiltrator units are used the bed dimensions arel2' wide and 87.5' long resulting in minimal change in the absorption bed footprint, and minimal affect on the setbacks. Installing 5 rows of 11 units results in an absorption bed of I S' wide and 68.75' long. The change in bed dimensions will change the setbacks slightly, however the changes will not affect the design. The only setback that is impacted is the setback to the ditch. The PVC liner adjacent to the bed provided conformance to the setback to the ditch. This PVC liner is still required for the proposed bed utilizing the standard infiltration units. If any additional information is requested, or if there are any questions or concerns regarding this information, please feel free to contact me at your convenience. 1517 BLAKE AVENUE, SUITE 101 GLEN WOOD SPRINGS, Cos 1601 970945-8676. PHONE 97"4W555 • I" WYV W.NCENG.COM 14 INVERNESS DRIVE EAST, SUITE F-120 ENGLEWOOD, CO 801 12 303.925-0644 • PHONE 303.925-0547 •rAX Jul.11. 2005 3 07PM HICOUNTRY ENGINEERING CIVIL ENGINEERING TO: CARLA BLOCK Caa coliti HCIES- 1 r�r. ' I NE Ela. MEMORANDUM FROM: JEFF ODOR, HIGH COUNTRY ENGINEERING DATE: 7-11-05 SUBJECT: DIAMOND J GUEST RANCH HCE PROJECT NO: 2041709.00 No -2046 P. 2 0 LAND SURVEYING Please refer to the attached detail for the PVC liner installation adjacent to the absorption beds. The liner shall be a 20 mil or a doubled 10 mil PVC material. The PVC liner shall be installed along the bottom and side of the trench and be anchored 1 R. horizontally at the top with 1 ft. of cover. Backfill shall be free of lagged or sharp rocks and primarily consist of Y:' material. The PVC liner and trench shall be installed approximately 5 ft. from the edge of the absorption bed to a minimum depth equal to the elevation of the nearby ditch. Refer to the memo dated 7-6-05 for additional information regarding the depth of the liner. 1517 BLAKE AVENUE, SUITE 10 1 GL6NWDOD SPRINGS, CO 81601 9709458676• PHONE 97"4G2555•FAx WWW.HCENG.COM 14 INVERNESS DRIVE EAST. $URE F-120 LNGLEWOoo, CO 80112 303-925-0544•PNONE 3039250547•FAa Jul II. 2005= 3:08WIGII"OUNTRY ENGINEERING No.2046=P• 6 0 ANCHOR PVC LINER 1' MINIMUM HORIZONTALLY APPROXIMATELY V COVER COMPACTED BACKFILL. MATERIAL SHALL BE FREE OF JAGGED OR SHARP ROCKS. BACKFILL SHALL CONSIST PRIMARILY OF MATERIAL SMALLER THAN 1/4" DIA NATURAL BACKFILL 12" MIN. COVER 36" MAX. COVER EXISTING GROUND GRADE INFILTRATOR UNIT TO DRAIN S• f / I Xy NATURAL GROUND J TRENCH BOTTOM ESTABLISHED WITH NOTE' EXCAVATION EQUIPMENT. TRENCH DEPTH RECOMMEND MINIMUM BURY DEPTH TO BE DETERMINED IN FIELD BY ON INFILTRATORS OR BIGHT MOUND CONTRACTOR PRIOR TO CONSTRUCTION PER MEMO DATED 7-6-05 TO ACHIEVE REOUIRED COVER. 20 MIL PVC LINER OR 10 MIL PVC LINER DOUBLED INSTALL ACROSS BOTTOM OF TRENCH AND ALONG SIDE TYPICAL CROSS SECTION N.T.S. HIGH COUNTRY ENGINEERING, INC. CDNMDEVELOPWNTCD FMYArfis&m iso N.rs. P"yjN cOUN7v. c0LODADO CHECKED BY AR +AINVERN[fi�(]03�9P6T806TSN TAI LlD1NO 2606 �.co 6a11z DIAMONDJ GUEST RANCH RDN 2041700.00 1617 BL 4E AVE NUE SIE 101_ GLEN D BPRINOB. CO B 1601 PVC TRENCH DETAIL DATE PAGE' 7.11'05 PNONE 49)011YM F11K16A19160666 www.+scw FILE: J %505KPRo.1\204\+709\DwB\O[T2.DBrti )3 Jul. 6. 2005 11:04AM 116 COUNTRY ENGINEERING CIVIL ENGINEERING ,U �,mamm c••c.,�. MEMORANDUM TO: CARLA BLOCK FROM: JEFF ODOR, HIGH COUNTRY ENGINEERING DATE: 7-6-05 SUBJECT: DIAMOND J GUEST RANCH HCE PROJECT No: 2041709.00 ND 19D7 P. 2/2 0 LAND SURVEYING The cabin community ISDS includes a PVC liner adjacent to the absorption field. The required setback between the absorption field and a ditch or waterway is 50' plus 8' additional distance for each 100 gpd of design flow over 1000 gpd resulting in 98' for this proposed system. The setback is based on an average flow of 1100 gpd with a peak of 1.5 (used for setbacks) resulting in 48 additional feet of setback to total 98 feet (I 100 gpd x 1.5 = 1650 gpd; 6x8 ft = 48 ft; 50' + 48' = 98'). This setback may be reduced according to the following excerpt from the Pitkin County ISDS Regulations; "Based on geological conditions and/or engineering controls and evaluation of risk of contamination of surface water and ground water, it is not necessary to add 8 feet additional distance for each 100 gallons of wastewater per day of design flow over 1000 gallons per day of design flow over 1,000 gallons per day as specified in the table to prevent contamination. The 50 -foot separation between the proposed absorption area and surface water and/or ground water is appropriate to prevent contamination." A minimum setback of 50' shall be maintained, however, the contractor should attempt to maximize the setback distance to further insure water quality. Prior to installation of the PVC liner, the contractor must determine the lowest ditch elevation within 98' of the proposed absorption bed. The PVC liner must extend down to an elevation equal to the lowest elevation of the bottom of the nearby ditch. The engineer shall be notified of the elevation and liner depth prior to installation of the liner for approval. The determined elevation needs to relate to a nearby reference object for engineer verification. 1517 BLAKE AVENUE, SUITE 101 GLENwooD SPRINGS, CO 81 AO 1 970945,a878• PHONE 970.9452585 • FAX Y .HCENG.COM 14 INVERNEBB DRIVE EA ,SURE F•120 ENGLEWOOD, co 80112 3039250544• PHONE 303.9254547•FAx i CIVIL ENGINEERING November 28, 2005 0 An Emplora-Owned Company. Carla Block Pitkin County Environmental Health 0405 Castle Creek Rd, Suite 10 Aspen, CO 81611 Re: Diamond J Guest Ranch ISDS HCE Project Number 2041709.00 x 0218 Cabin Community Dear Carla: J LAND SURVEYING The following letter is to confirm the engineer's acceptance of the installed septic system for the Cabin Community of the Diamond J Guest Ranch on Frying Pan Road (County Road 4). The design included a single separate individual sewage disposal system (ISDS) for cabins Cl, C2, C3, C8, C9 and C13. Based on field inspections, the ISDS fields have been installed per the intent of the plans and specifications. The installed collection piping was changed from the original design due to existing site conditions. The location of the infiltration gallery was changed to better fit the existing conditions. A record drawing of the installed system is provided. If you have any questions, or need additional information, please contact us. Sincerely, Q RDN/hnm Enclosure 1517 Blake Avenue, Suite 101 14 Inverness Drive East, Suite F-120 Glenwood Springs, CO 81601 Englewood, CO 80112 970.945.8676 phone 303.925.0544 phone 5 970.945.2555 fax www.hceng.com 303.925.0547 fax 0 A October 28, 2005 Thomas H. Stewart P.O. Box 541057 Dallas, TX 75354-1057 Re: Parcel ID #: 2473-201-00-005 Property Address: 26604 Frying Pan Road Permit Numbers: 05015, 05025, 05031, and 05032 Dear Mr. Stewart: As per our correspondences to you on July 6 and 20, 2005 as well as September 5, 2005 (separately for each permit number), the Environmental Health & Natural Resources Department would like to remind you that we are still unable to complete the processing of the Individual Sewage Disposal System (ISDS) permits for the above stated residence/property. It is mandatory that our office receives an "As Built" letter for each permit from the engineer who designed the system. The letter will confirm that they observed the installation of the system as designed. Any changes to the system must be noted in the letter or by a new set of plans. The Building Department will not issue a Certificate of Occupancy for this property until they are notified that the ISDS permit process is complete. This office must receive the "As Built" letters from the engineer no later than November 17, 2005. Please contact me with any questions. Thank you, in advance, for your help and cooperation in this matter. Sincerely, Alicia Gomez Administrative Assistant Environmental Health & Natural Resources cc: Jeff Odor, P.E., High Country Engineering I� Jun.30. 2005 9 21AMHHIG COUNTRY ENGINEERING HCPWORTH-PAWLAK GEOTECHNICAL Julie 28, 2005 No 1154 P. 4/6' "' ' t;11Cnw'txnl tipnry :.J,..�.t 5:10.11 97,1-4�i 71n �an:�il: C,�gS,'uhrgc.,tccl...:o:n Tommy Stewart P.O. Box 541057 Dallas. Texas 75354-1057 .lob No. 104 456-1 Subject. Percolation Testing. Proposed Septic Disposal System. Cabin Community. Diamond J Ranch, 26604 Prying Pan Road, Pitkin County, Colorddo. Dear Mr. Stewart: As requested by Tim Case, Hepworth - Pawlak Geotechnical, Inc., performed percolation testing at the subject site. We previously conducted a subsoil study and percolation testing at the Diamond J Ranch and presented our findings in a report dated October 20, 2004; Job No. 104 456-1. A profile pit and three percolation test holes had been excavated by the client prior to our anival. The subsoils exposed in the Prot' 1E Pit consisted of about 2'/ feet Of topsoil overlying slightly clayey silty sandy gravel with cobbles and boulders up io about 3 feet in size to the pit depth of 7 feet. No free ;•_atcr was observed in the pit and the soils were slightly moist. Percolation test holes had bsen dug in the gravel soils and soaked by the client prior to our arrival on-site. Percolation testing was conducted on June 22, 2005, by a representative of Hepworth - Pawlak Geotechnical, Inc. The percolation test results are summarized on Table 1. The percolation tests indicated uttiltration rates between 9 and 12 minutes per inch with an average of 10 minutes per inch. Jf you have any questions or need further assistance, please call Our office. Sincerely, HE?P WORTH - PA WLA'K INC:. Jordy Z. Adamson, IT., P. -o' Q �,, 6/�•� ;j��`` JUN 8 2005 Rev. by: DEH SSS/pj�Al ANG JZA/ksw ENVIRO KIM COUNTY attachments Figure 1 — Location o rcolation Test Holes NMENTAL HEALTH Table I -Percolation Teal Results cc: High Country bngiaeering — At Jeff Odor PaNeceived TimetJun.30-r'9:I5AM,prinse,749"633-5562 • Silverthome. 970-468-1989 Iq Juo.30 2005 9 21AM HIGH COUNTRY ENGINEERING • No 1754 P. 5/6 ",". Jun 3D. 2005 9 21AM HIGH COUNTRY ENGINEERING HEPWORTH-PAWLAK GEOTECHNICAL, INC. TABLE 1 PERCOLATION TEST RESULTS No. 1754 P. 6/6,u ," JOB NO. ID4 456-1 HOLE NO. HOLE DEPTH (INCHES) LENGTH OF INTERVAL (MIN) WATER DEPTH AT START OF ItTERVAL INCHES WATER DEPTH AT END OF INTERVAL INCHES DROP IN WATER LEVEL (INCHES) AVERAGE PERCOLATION RATE (MIN_/INCH) P-1 Water added 9 234 13A 1 1 3/4 -- �1i4 7 Si. 1'A 534 5 34 _ 5 4 1 4 31/4 34 3'/4 2% 'h 23/4 2% V2 21/4 11A 34 P-2 50 5 Water added 33/4 31/4 'h 9 3'/4 3 '/4 3 2'h 1/2 2% 2 '/2 7'h 6yz 1 61h 53/4 3/4 5% - 51/4 4'h 3/4 41/2 4 '/2 4 3 V2 Vz P-3 56 5—t23/4 Water added 13/4 1/1 12 8 63'4 1'/4 63/4 5% 1 53y.. 5 3/4 5 4'/A 3/4 .4% 33/4 'h 33/4 31A '/z '- 31/4 23/4 V2 p/4 2`6 /z 21/4 2 1/4 Note: Percolation test holes had been in the bottom of backhoe pits and soaked by the client prior to our testing. Percolation tests were conducted on June 22, 7.005. The average 7p.rcolation rates were based on the last three readings of each test. Received Time Jun.30• 9:15AN' TOTAL P.84 PITKIN ENVIRONMENTAL HEALTH DEPARTMENT ISDS DESIGN CALCULATIONS Owner's Name Parcel ID # House Size (sq. ft.) (75 gpd, 100 gpd, or 130 gpd) Number of Bedrooms in Main House Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House Number of Bedrooms in Detached Caretaker unit Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit (If the caretaker unit is ATTACHED, treat as if part of main house.) Average Daily Waste Flow 1100 1 I O O State Review Required? no Perc Rate (T) Design Flow (Q) = # potential bedrooms X 2 people/ bedroom X gpd X 1.75 Q= 1925 Minimum tank capacity 2406.25 gallons Absorption Area (=Q/5 X SART perc rate) 50 1050 FD CQ -e S,Zi nC� IASL n( _k4or 5f eCj Ji n(� oY A = 1217.4769 sq. ft. of absorption area required 79 gravelless chamber units without reduction # of Perc Holes Required: 3 1 in every soil type? Spaced uniformly over proposed area? DICK 4 9_8 A = 608.73845 sq.ft. with 50% reductionTRENCHES 62 gravelless chamber units with reduction STANDARD A = 608.73845 sq.ft. with 50% reductionTRENCHES 39 gravelless chamber units with reduction EQ 36 38 EQ36 units in TRENCHES UQ ICK 4 9.2 852.23383 sq ft 30% reduction BED 93 chamber units with reduc. C85223383 sq ft %reduction BED 55 ch ber units with reduc. SSETBACKFR MWE17 # of feet LL 1621 S��CJQCV� SETBACK MPO , STREAM OR IRRIGATION DITCH #of feet= 124 ��back SETBACK FROM DRY GULCH IDD # of feet = 99 M 68 EQ36 units in a BED H� G( tech HEPWORTH-PAWLAK GEOTECHNICAL October 20, 2004 Tommy Stewart P.O. Box 541057 Hep&Pawlak Geotechnical, Inc 5020 County Road 154 Glenwood Springs, Colorado 81601 Phone: 970.945-7988 Fax: 970-945-8454 email: hpgeo®hpgwtech.com Dallas, Texas 75354-1057 Job No. 104 456-1 Subject: Subsoil Study for Foundation Design and Percolation Testing, Proposed Cabin, Diamond J Ranch, 26604 Frying Pan Road, Pitkin County, Colorado. Dear Mr. Stewart: As requested, Hepworth-Pawlak Geotechnical, Inc. performed a subsoil study and percolation test for foundation and septic disposal designs at the subject site. The study was conducted in accordance with our agreement for geotechnical engineering services to you dated October 11, 2004. An additional percolation test was requested in the area between Cabins I and 2. The data obtained and our recommendations based on the proposed construction and subsurface conditions encountered are presented in this report. Hepworth-Pawlak Geotechnical, Inc. previously conducted percolation testing for a cabin in the area of the existing corral and presented our findings in a report dated July 29, 2004, Job No. 104 456. Proposed Construction: The existing cabin at the site (Cabin 5) will be relocated in the area between Cabins 1 and 2, shown on Figure 1. The proposed cabin will be a single story log structure over a crawlspace. The cabin will be about 1,344 square feet in size. Cut depths are expected to be about 4 feet. Foundation loadings for this type of construction are assumed to be relatively light and typical of the proposed type of construction. The septic disposal system is proposed to be located to the north of the proposed cabin. If building conditions or foundation loadings are significantly different from those described above, we should be notified to re-evaluate the recommendations presented in this report. Site Conditions: There are numerous cabins located on the property. The cabins consist of one to two story log structures. The ground surface in the proposed building area is relatively flat with a gentle slope down to the northwest. There is about 2 to 4 feet of elevation difference across the proposed cabin site. A creek is located to the northeast of the proposed cabin. Vegetation consists of scattered evergreen and aspen trees, grass and weeds. Cobbles and boulders up to about 10 feet in size are exposed on the ground surface. Subsurface Conditions: The subsurface conditions at the site were evaluated by excavating two exploratory pits in the building area and one profile pit in the septic Parker 303-841-7119 0 Colorado Springs 719-633-5562 • Silverthome 970-468-1989 -2 - disposal area at the approximate locations shown on Figure 1. The logs of the pits are presented on Figure 2. The subsoils encountered, below about 1 Meet of topsoil, consist of relatively dense, slightly clayey silty sandy gravel with cobbles and boulders up to about 8 feet in size to the pit depths of 6%: feet. Results of gradation analyses performed on samples of the gravels (minus 3 inch fraction) obtained from the pits are presented on Figure 3. Atterberg limits testing indicates the matrix to be silty with low plasticity. Groundwater was encountered in Pit 2 at a depth of 5 feet. No free water was encountered in Pit 1 at the time of excavation and the soils were typically slightly moist to moist. Foundation Recommendations: Considering the subsoil conditions encountered in the exploratory pits and the nature of the proposed construction, we recommend spread footings placed on the undisturbed natural gravel soil designed for an allowable soil bearing pressure of 2,500 psf for support of the proposed cabin. Footings should be a minimum width of 16 inches for continuous walls and 2 feet for columns. Loose and disturbed soils encountered at the foundation bearing level within the excavation should be removed and the footing bearing level extended down to the undisturbed natural gravel soils. Voids created by the removal of large rocks should be backfilled with compacted sand and gravel or with concrete. Exterior footings should be provided with adequate cover above their bearing elevations for frost protection. Placement of footings at least 42 inches below the exterior grade is recommended for this area. Continuous foundation walls should be reinforced top and bottom to span local anomalies such as by assuming an unsupported length of at least 10 feet. Foundation walls acting as retaining structures should be designed to resist a lateral earth pressure based on an equivalent fluid unit weight of at least 50 pcf for the on-site soil as backfill, excluding rock larger than about 6 inches. Floor Slabs: Currently no floor slabs are proposed. However, there may be some exterior slabs in the future. The natural on-site soils, exclusive of topsoil, are suitable to support lightly loaded slab -on -grade construction. To reduce the effects of some differential movement, floor slabs should be separated from all bearing walls and columns with expansion joints which allow unrestrained vertical movement. Floor slab control joints should be used to reduce damage due to shrinkage cracking. The requirements for joint spacing and slab reinforcement should be established by the designer based on experience and the intended slab use. A minimum 4 inch layer of sand and gravel should be placed beneath slabs -on -grade as a leveling course. This material should consist of minus 2 inch aggregate with less than 50% passing the No. 4 sieve and less than 12% passing the No. 200 sieve. All fill materials for support of floor slabs should be compacted to at least 95% of maximum standard Proctor density at a moisture content near optimum. Required fill can consist of the on-site soils devoid of vegetation, topsoil and oversized rock. Surface Drainage: The following drainage precautions should be observed during construction and maintained at all times after the cabin has been completed: I) Inundation of the foundation excavations and underslab areas should be avoided during construction. Job No. 104 4561 QJ WME.ls'1i 0 -3- 0 2) Exterior backfill should be adjusted to near optimum moisture and compacted to at least 95% of the maximum standard Proctor density in pavement and slab areas and to at least 90% of the maximum standard Proctor density in landscape areas. 3) The ground surface surrounding the exterior of the building should be sloped to drain away from the foundation in all directions. We recommend a minimum slope of 6 inches in the first 10 feet in unpaved areas and a minimum slope of 3 inches in the first 10 feet in pavement and walkway areas. 4) Roof downspouts and drains should discharge well beyond the limits of all backfill. Percolation Testing: Percolation tests were conducted on October 13, 2004 to evaluate the feasibility of infiltration septic disposal systems at the site. One profile pit and three percolation holes were dug in two areas at the locations shown on Figure 1. The test holes (nominal 12 inch diameter by 12 inch deep) were hand dug at the bottom of shallow backhoe pits and were soaked with water one day prior to testing. The soils exposed in the percolation holes are similar to those exposed in the Profile Pits shown on Figure 2 and consist of 1 to 1'h feet of topsoil overlying slightly clayey, silty sandy gravel with cobbles and boulders to the pit depths of 8 feet. PVC and corrugated metal pipes were installed in the pits to measure future water levels. The percolation test results are presented in Table 1. The percolation test results indicate an infiltration rate between 13 and 36 minutes per inch with an average of 26 minutes per inch for Area 1. An infiltration rate between 17 and 20 minutes per inch with an average of 18 minutes per inch was indicated for the Area 2 testing. Based on the subsurface conditions encountered and the percolation test results, the tested areas should be suitable for conventional infiltration septic disposal systems. Pitkin County requires a professional engineer design the infiltration septic disposal systems. Limitations: This study has been conducted in accordance with generally accepted geotechnical engineering principles and practices in this area at this time. We make no warranty either express or implied. The conclusions and recommendations submitted in this report are based upon the data obtained from the exploratory pits excavated at the locations indicated on Figure 1, the proposed type of construction and our experience in the area. Our services do not include determining the presence, prevention or possibility of mold or other biological contaminants (MOBC) developing in the future. If the client is concerned about MOBC, then a professional in this special field of practice should be consulted. Our findings include interpolation and extrapolation of the subsurface conditions identified at the exploratory pits and variations in the subsurface conditions may not become evident until excavation is performed. If conditions encountered during construction appear different from those described in this report, we should be notified at once so re-evaluation of the recommendations may be made. This report has been prepared for the exclusive use by our client for design purposes. We are not responsible for technical interpretations by others of our information. As the project evolves, we should provide continued consultation and field services during construction to review and monitor the implementation of our recommendations, and to Job No. 104 456-1 Q3 Asea, 1] 0 verify that the recommendations have been appropriately interpreted. Significant design changes may require additional analysis or modifications to the recommendations presented herein. We recommend on-site observation of excavations and foundation bearing strata and testing of structural fill by a representative of the geotechnical engineer. If you have any questions or if we may be of further assistance, please let us know. Respectfully Submitted, HEPWORTH - PAWLAK GEOTECINIC.AL. INC. 24 Jordy Z. Adamson, Jr., Reviewed by: Steven L. Pawlak, P.E. PMANM. attachments Figure 1 — Location of Exploratory Pits and Percolation Test Holes Figure 2 — Logs of Exploratory Pits Figure 3 — Gradation Test Results Table I — Percolation Test Results cc: High Country Engineering — Attn: Greg Shaner Job No. 104 456-I 1� (-+ GctTtea, PROPERTY BOUNDARIES EXISTING CORRAL EXISTING 18 PUMP HPC N1 WSEO16 \\\ It m `L 1 PIT 1 06 AREA 1 P -3A . PIT 2 EXISTING CABIN (TYPICAL) �r%%z 1PROFl AREA 2 PIT 2 0 4 P-3 P-1 Q STEPHENSON PROPERTY DIAMOND JOY GUEST RANCH PON l� 1 I (PO .. _ 022 PIT 1 I / APPROXIMATE SCALE 1`=140' I HEPWORTH—PAWLAK LOCATION OF EXPLORATORY PITS AND Figure 1 104 456-1 GEOTECHNICAL, INC. PERCOLATION TEST HOLES QPM PIT 1 PIT 2 0 PROFILE PIT 1 PROFLE PIT 2 0 ;o-- LL li '1:,0, •l-•0. •Y4. - - 5 I L::a• =33+4=41 +4 .a 'd L •• _ o -200-19 -20023 p LL -21 LL19 .A• P1-2 PI -2 IM L_ 10 LEGEND: NTOPSOIL; sandy clay, slightly organic, firm, slightly moist, brown. guo GRAVEL (GM); silty, sandy, slightly clayey, with cobbles and boulders up to about 8 feet in size, •' . medium dense to dense, slightly moist to moist, moist to wet below water in Pit 2, brown, subrounded rock. j Disturbed bulk sample. Free water level in pit at the time of excavation. MIndicates 2' PVC pipe was installed in pit. e [a Indicates 12' corrugated metal pipe was installed in pit. NOTES: 1. Exploratory pits were excavated on October 12, 2004 with a Caterpillar 315L trackhoe. 2.. Locations of exploratory pits were measured_approxirtlately by_pacing_from features shown _on. the _ site plan provided. 3. Elevations of exploratory pits were not measured and the logs of exploratory pits are drawn to depth. 4. The exploratory pit locations should be considered accurate only to the degree implied by the method used. 5. The lines between materials shown on the exploratory pit logs represent the approximate boundaries between material types and transitions may be gradual. 6. Water level readings shown on the logs were made at the time and under the conditions indicated. Fluctuation in water level may occur with time. 7. Laboratory Testing Results: +4 = Percent retained on the No. 4 sieve LL = Liquid Limit ( % ) —200 = Percent passing No. 200 sieve PI = Plasticity Index ( % ) 104 456-1 HEPWORTH—PAWLAK LOGS OF EXPLORATORY PITS Figure 2 GEOTECHNICAL, INC. HEPWORTH-PAWLAK GEOTECHNICAL, INC. TABLE 1 PERCOLATION TEST RESULTS JOB NO. 104 456-1 Page 1 of 2 HOLE NO. HOLE DEPTH (INCHES) LENGTH OF INTERVAL (MIN) WATER DEPTH AT START OF INTERVAL INCHES WATER DEPTH AT END OF INTERVAL INCHES DROP IN WATER LEVEL (INCHES) AVERAGE PERCOLATION RATE (MINJINCH) P-1 (Area 1) 58 15 8 7 1 30 7 6 1 6 6 0 6 51/2 1/z 5 1/2 5 1/2 5 41/2 1/2 41/2 4 1/2 4 31/2 '/z P-2 (Area 1) 44 15 Water added Water added 71/4 5 1/2 1 3/a 13 5 1/2 4 1 1/2 71/2 6 Vz 1 6 '/z 5 1 1/2 5 4 1 71/2 6 1 1/2 6 5 1 5 4 1 P-3 (Area 1) 50 15 71/2 7 1/2 36 7 61/2 '/z 61/2 61/4 '/a 61/4 6 1/a 6 5 1/2 '/z 51/2 5 '/a 1/4 5 1/4 4 3/4 1/2 43/4 1 4 1/2 1/3 Note: Percolation test holes were hand dug in the bottom of backhoe pits and soaked on October 12, 2004. Percolation tests were conducted on October 13, 2004. The average percolation rates were based on the last three readings of each test. M. HEPWORTH-PAWLAK GEOTECHNICAL, INC. TABLE 1 PERCOLATION TEST RESULTS JOB NO. 104 456-1 Page 2 of 2 HOLE NO. HOLE DEPTH (INCHES) LENGTH OF INTERVAL (MIN) WATER DEPTH AT START OF INTERVAL INCHES WATER DEPTH AT END OF INTERVAL INCHES DROP IN WATER LEVEL (INCHES) AVERAGE PERCOLATION RATE (MIN./INCH) P-1 (Area 2) 46 15 Water added 9 71/2 1 1/2 20 71/2 61/2 1 61/2 5 1 1/2 5 4 1 8 7 1 7 6 1 6 5 1/4 3/4 51/4 41/2 3/4 P-2 (Area 2) 40 15 Water added 9 8 1 17 8 7 1 7 6 1 6 51/4 3/4 81/2 7 1/2 1 71/2 63/4 3/4 63/4 6 3/4 6 5 1 P-3 (Area 2) 42 15 Water added 10 1/2 9 1 1/2 17 9 8 1 8 7 1 7 61/2 1/2 61/2 5 3/4 3/4 5 3/4 5 3/4 10 9 1 9 1 81/4 3/4 Note: Percolation test holes were hand dug in the bottom of backhoe pits and soaked on October 12, 2004. Percolation tests were conducted on October 13, 2004. The average percolation rates were based on the last three readings of each test. 1. VALLEYVIEW 4/l/2005 0 i 0 0 2. LONGBRANCH rq„=i, 4/l/2005 7) • • • • 2a. MOUNTAIN VIEW 4/l/2005 C6 3. LARKSPUR 4/l/2005 E 0 E SUNSET �.1°=1' 4/l/2005 0 0 0 0 E C C 4/l/2005 i r] --- 8. RED MOUNTAIN 4/l/2005 M • .I L • ��7 9. BUCKHORN 4/l/2005 � 0 I * KI 10. COLUMBINE '/4"=I' 4/1/2005 12. MCGEE %a"=1' 4/l/2005 cT M . _.__ � 13. HERMITAGE �4"=1' CC� S 0 4/l/2005 ,J T 07/07/2003 16:07 9709256%8 PAGE 19/28 JUL-07-2003 09:11AY FROM-D1V5WA 9709453741 T-178 P.003/004 F-752 WRJ•5•Rer. 76 COL. ADO DIVISION OF WATER RESOUR i 818 Centennial Bldg., 1313 Sherman Sr-, Denver, Colorado 60203 . RECEIVED Application must be complete where applicable. Type or print in BLACK fes, No overstrike: or erasures unless initialed. NAME Bruce R. Riley PERMIT APPLICATION FORM ( X) A PERMIT TO USE GROUND WATER ( X) A PERMIT TO CONSTRUCT A WELL FOR: ( X) A PERMIT TO INSTALL A PUMP REPLACEMENT FOR NO. i OTHER WATER COURT CASE N0. STREET 26604 Fry'iAg Pan Road CITY Meredith Colorado 816142 [state) lzia7 TELEPHONE NO. 927-3222 LOCATION OF PROPOSED WELL Countv Pitkin Co. NE Y. of the NE X Section 20 Twp. 8 S, Rng.83 W (ICSH IE,vn (3) Proposed maximum pumping rate (gpm) 30 gpm max. Average annual amount of ground water to be appropriated (aae-feet): 5A.F/Yr.. Number of acres to be irrigated: None] Proposed total depth Ifeetl: 130 Ft. Aquifer ground water is to be obtalned from: Owner's well designation GROUND WATER TO BE USED FOS: I XI HOUSEHOLD USE ONLY 1 g) DOMESTIC (1) ( X) LIVESTOCK 12) 1 XJECOMMERCIAL (4) I IOTHER no irrigation (0) ( I INDUSTRIAL (5) I ) IRRIGATION (6) ( 1 MUNICIPAL (B) (DETAIL THE USE ON BACK IN 01) (4) DRILLER Name lxctmta„ n rwan74niz Street 5062 113 Road Gly Glenwood Spee C�1A o ado ;}�Q1 utel IZial Telephone No. 245-5148 Lic. No, 697 X5605'77 TER RLOURQU ,. MTE ENGWcFa LOiA. FOR OFFICE USE ONLY: DO NOT WRITE IN THIS COLUMN Receipt No. 81/ 3 S 1 Basin Dist. CONDITIONS OF APPROVAL This well shall be used in such a way as to cause no material injury to existing water rights. The issuance of the permit does not assure the applicant tnat no injury will occur to another vested water right or preclude another owner of a vested water right from seeking relief in a civil court action. 1)'A DECREE FOR TRIS APPROYRTATION MST BE OBTAFROM THE DISTRICT COURT IN AND FOR WAT DIV, NO. 5, SPATE OF COLORADO FRIAR TO THE USE OF THIS WELL, THIS APPROVAL IS SUBJECT TO THE TERMS OF SAID DECR3E. 2) A LTTMIOGIC TOG OF THIS WELL SBALL BE PRE - T= BY ErTJlER A COMPETENT WATER WELL CONTRACT OR A Q[Rt.LIFIED GEOI XSIST. 3) 17HE H 1,TIM RATE OF TRIS WELL SHALL BE LTNIT TO 30 GPM OR THE ACTUAL YTELD OF THE AQUIM, WHICEEVER is LESS. 4) TOTALIZING F1,OW METER MUST 2E INM-IM ON T' WELL DISCHARGE WHEN THE WATER IS PUT TO BEfiE- FICIAL USE. DIVERSION RECORDS SHALL BE SLMMITTi UPON REQUESTa TO THE DIVISION OF WATER RESOLI APPLICATION APPROVED PERMIT NUMBER 228 90 - F DATE ISSUED 0 NOV 08 n 1p977 t� EXPIRATION DATE N1 Oil 8 1970 _ (STATEN EER) BY--- I.D. 5 —39 --COUNTY c 07/07/2003 16:07 9709254666 PAGE 20/28 JUL-07-2003 09:11A11 FRO" IV59iATE 9709450741 0 T-175 P.O04/004 f•762 (5) THE LOCATION OF THE PROPOSED WELL and the area on (6) THE WELL MUST BE LOCATED BEL Q_17f .. b d'sv from section lines. •=` Il the water will be ustd must be Indicated on the diagram blow. Y 1 . otos , Uro **.CENTER, SECTION 0 sm6on. 840 aces) for the wrll 100608. 800 h from Porth sea line - 200 'Gast .•. L•. ...:. seesfle It, ,♦.. ,i'b.ci:4�!�-1YM E. �Oi#Ei^R ", (T'•'r figs l.estd Will ,+•r.t?t '�'J�� i �± '( 'i' ,•'• �#'; :w�., ':.. i .1 -.LAT.' J. pLOCK FILING • .r •.v<':�:•'",t`:r- 't i •/ f♦� SUl1DIVISION, 1 .:7•-Yn'r{-'+,��(,vA,': SECTION LINE 1. rp•'•''{'••i .� I - (7) TRACT Of4' L"'RICH WELt VILILI LOCATED Omer: Bruce R. Riley +NON" +tit`. —,'F — i No. of ewes 28.05 Will this be • I ' 3'` z ) :I . `' :,:.::4 the only well on this �- trach B ' T IN ;F .,� . ~ +.: . (el PROPOSED CASING PROGRAM ' .)•� 'M+r ��C�w r.i:. ',: �:• :r: ' •_isf. .n,, 1 [: rs't:�•'a' 'i: ;'PlsinCasTllg:..}'.. �' '- ' ,+ ,• 1 Y +,. '.7w IQ. *cm0 100 1 ft ..�.,: 1Y re S '�'-f �s'r��'x• I�didiTy. `•i•c;:Lrr . baf'�-y!'�u '!'r�� {n,,..r:.. ,l. �'.. d:.�� " .. _ ..N n+':.Y .F2 "�'y"'I� �,^'`hf'r('ttL',�rT '1".t.`('�it'"'f�•'et,"�i`*-� 'h.�'',•I,'�' h� - `� �'' 'y fL tD n. 1. J:'Fvy �`';'F''• y'Ecy,1ON LING: •w,+ p� '-{'; •._.,'� .�•, �: , _.'. - • , • s +' 1 t' 'r'le'Ni,t" : ii.' • 'r 1'�-: �'.• `t✓ i.iFil :'vi ::'y' 't 'i„ • rt fie. ft.:o �♦�� .�+''. l ; f i_.:. i : 't • �:::' :_g Fiat �i •`f':1 ;Y::1� SWIh" •(� ry..t„ i Yt. 1 ar:•y �iY.,-4Y,,/'� ''1`, f4fo .M !.r �., 1+:•�l: F��+t•\i•-'-, • +: -itir#•.1l ;I ••�.-.T .�^T ki.' 't +••�,; -in fi m (9) FOR REPLACEMENT WELLS give distance ::•Y.s• ;: , �.:mia discion_irolnvldwellsldplalltforaugging ,+ '�'•w.•l?1 Ji'• C r.I :.. �..r�:,1 :s•+�'=�, t�`'XJ1j ai•t� .11 rel.. rt `�'� - ' Y:ri�.'_ Y•y I(.1. .: ir' i>J•5,Yf4t t.• .1 �/ scab of the diagram is 2 irscFles:r 1;tIaN,,•._ ,~.!':'• . Al �. - . � � • •:.:-' Each small square re resents AO sln7fa.' •.- ,: - r t•w';, Y v WATER EQUIVALENTS TABLEfliopndedFl,WNII:: •rl a "; �' An Sol co.en 1 acro of la+d 1 foot daD .:•. ♦ •,1 eamTly of per serntd lead Im elY 1 0 1w00 of 191 Mier • a ` A lamps of 5 wiY require sppro%Imately 1 ecrrf00t of water ver War• ' ` . 1 wrrToot ...43;560 wbic last :..336,900 gelbns- aA2 sae -fast. 1,0MVpm tanmped continuously torono day producer. (10) ND WHICH G D W TE E Owner(s): 11A8 R. Ria - No. of aeres:,�R ,i j I DEJAILED-PISMEDMOf the use of ground water: Household use and domestic wells must indicate type.o} disposal sysmm to be used. Colmaeroisl Mgt ranch With afsty r three teenths, domestic for ar e (1P) nTUFR WOT R Rf +H S.used on this land, including wells. Give Registration. and Water Court Case Numbers. •�"'T: 'Used for (FillDezaiptidn oGlard on which usedType: .. Surface n Commeroia1,33�estdllkeatt • siring Comgeroia 'lives s ,.(13iTHE A?PLICANT(S) STATES) .THAI' THE INFORMATION SET�FO:HEREON IS OWl.EDGESK'.��"=-:,r...•... .;.:,,.•.. ..r•y .. '• � ;l:i' ..'!':�nu.•r rae'eC.'diM_lCdatiQS1:� _3_'Y'����t�::'lv�!W •1�aCa1Ta�>..._: �•tti4e2�y}.4•....r.+el•.'.,•::%'^.:•:�..•`t•,9..:_s,:i,'!•: �r.•..t'rA.:.�`• .. --.�'%Tr.-.:eEN.r.."_�i'''q t9X4:R.g�:S)�FiiiTr" ��i •dlsr-tifRari: _.... r:•�rsemw.-. -r..:. �•-�rm.....�-... 0 �' ASPEN7 = a' :. I1L _ 1 ' t: ►/_III My! • BU1LDMG.PERNffT APPLICAMN ' a. 1 .[ TO OkAUqNG 11MOTUM&LSEWAGE DISPOSAL SYSTEbt' _ ' III . I Connell Development Company - (printed owner's name) accept the responsibility for obtaining all soil information and other requirements of the Environmental Health Department that are necessary to obtain au • Individual Sewage Disposal System (ISDS) -permit, and know that a'building permit will not be issued until the ISDS permit has been issued. I recognize that I am submitting my application for a building permit without completing the necessary field work to obtain a permit to construct in ISDS. 1 realize that I may incur additional expense in the form of „ -plan check, energy code, and zoning review fees if changes to my original plan are. ,necessary. I recognize that, by entering the building, permit application process in this fashion, I am taking a risk that might ultimately mean I cannot build on the property in question, the dwelling might be smaller tha4 originally designed, and that Lmight have to subunit an entirely new set of plans. I further accept the fact that by having to resubmit plans it may cause extended delays to'issuance of the permit to construct. This waiverwill not apply if the project has had a previous condition of approval by -Pitkin County' stating that an ISDS permit must be obtained prior to submitting plans to the Building Department- If the applicant wants to apply for the "Waiver" anyway, the applicant must request that the County change the condition of approval previously granted. Building permit plan review, energy code review, and zoning review fees are due at permit submittal and may not §Piefttn#ed. OWNER SIGNAT OWNER DESIGNATED REPRESENTATIVE: DA' (OPTIONAL) wstcrlsds aiv.dvc L) 3 ..:_.._: r.. _.. e...:,.... A�:, c.•a A7611-1975 • PnavE970.920b090 - FAx970.9205439 / ELEVATION OF BOTTOM \ �OF DITCH MUST BE VERIFIED / TO ESTABLISH PVC DEPTH ,. APPROXIMATE DITTCH AT BETWEEN ION OFTHE EXISTING PONDS 1 \ 10 MIL PVC LINER/ .L O MINIMUM DEPTH AL LTO THE DITCH BOTTOM INSTALL \ / CONNECTING THE NEARBY PONDS - `7 ^. . k � E)�ISTING SEPRIC TANK, 1AWIFOLD..PIPING EMOVED r SOMJ ENDS`- r "ELEAN`0U`T a I 4 148' PR P S D SEPTIC . ON INFLUENCE E� .•" ,..\\ ` 6OF 40 PVC i \ 6' OF 4"?D PVC '`" ,,..., . ">'r. SEWER 2% 1000 GALLON -SEWER-0 2% C/� - SEPTIC TANK (#4) v,.\, M I ^ , \.,,\ _ WITFT�EFFLUENT�FILTER - CLEAN CUT "\�-,.�`"�.._,�"'`~`�• � / S 1500 GALLON C1 �`� SEPTIC TANK T FILTER BS2PTIbN FIELD \ / " �y .��\7- 01- -,� WITH EFFLUENT FILTER'`' ,. - _ ; . SEW€R `® 2% %: ,� `• ° i �A ` X / 51' OF SEWER 4» id. �V A� 0 CLEAN OF 4",0 PVC ` :, ® V ,,EkISTI G EP�C�TA - SEWER 0 2% !!!� ASANQ D / 86' OF 0 PVC SEWER � P / \ 1 SEWERER 02% \ �% � / NEW WATERLINE SF 4" CLEAN JUNCTION BOX 7.5' OF 7, 5' 4' P ,OUT '/ 18' OF 1" .r WATER LINE Vf141' OF 4" 0 PVC r' r - �\ r,° \ SEWER 0 2% 81' OF 4" 0 PVC \ / f SEWER 0 2%,..- w NE WATERLINE d' 1 _ P JUNCTION BOX __-- --- � ---'---- -�` ��� /�''� 1�`� CLEAN10UT EXISTING SE TIC TANK C8 •' REMOVED C2 CLEAN OUT 35' OF 1" CLEA OUT �•., r WATER LINE CLEAN OUT WATER LINE 96 SEWER ®2% 20' ISDS SETBACK FROM ,CABIN _ \ / / _.- _ 86' OF 4"�0'PVV \if„W *. G3 \ /SEWER 0 2%� -- � � 58' OF 1" \ v / V411? LINE " \� Ii l \ \ WATER LINE \ / EXISTING SEPTIC TANK i \ ABANDONED 172' PROPOSED SEPTIC ZONE OF INFLUENCE CLEAN OUT ADJACENT ,SYSTEM / t CLEAN OUT NEW WATERLINE JUNCTION BOX � ,/ ISDBTA FO G9 r e -..- _- .! ADJA' NT STE `v \1X / 100' PROPOSED SEPTIC NOTES: 1, THE ZONE OF INFLUENCE FOR THE EXISTING ISDS IS ESTABLISHED BASED ON THE ASSUMPTION THAT THE EXISTING ao LODGE SEPTIC TANK IS AT FULL CAPACITY BUT NOT UNDER SIZED AT 1500 GALLONS. THIS CORRELATES TO A DESIGN FLOW OF 1200 GPM AND A SETBACK REQUIREMENT OF 116 FT. TABLE II TABLE OF MINIMUM HORIZONTAL DISTANCES IN FEET BETWEEN COMPONENTS OF A SEWAGE DISPOSAL SYSTEM INSTALLED AFTER NOVEMBER 15, 1973 AND PERTINENT PHYSICAL FEATURES Spring, Potable Potable Dwelling Property Lines, Subsoil Drains; Lake, Water Dry Septic Wells, Water Water Occupied Piped or Lined Intermittent Course, Irrigation Gulches Took Suction Supply Supply Building Irrigation Ditch Irrigation Lateral Ditch or Stream Lines Line Cistem 2 Dispersal System Utilizing (3T__(1 3)(4)(2) 2 3 4 -C- 4 1 -a'0& 400 (3) 25 (3) 10 10 C8 Aerosol Methods 100 10 50 125 10 0 - 4 �: rSrlir,dp ktl �V' * Seopage Ph.,Sih Trench (3) (4X2) U t O ID x W (3) (3) 25 6 WS 100 50 25 20 25 10 50 Absorption Trench, Seepage (3) (4)(2) m U r (3) (3) 25 5 SITEAa Bed, Sand Filter, Sub -surface 100 25 25 20 10 10 50 Dis ersal System, or Drywall Unlined Sand Filter in Soil (4X2) 15 0 With a Percolation Rate 100 25 25 IS 10 10 25 Slower than 60 Minutes per '.J 4 Inch - Unlined or Partially Lined 25 15 0 Evapotranspiration System, 100 (4X2) 25 15 10 10 Wastewater Pond, or Surface 25 Disposal System Other than Aerosol Lined Sand Filter 60 (4)(2) 25 IS 10 10 25 10 5 10 Lined Evapotranspiration (4)(2) 25 15 10 10 25 10 3 - Field or Lined Wastewater 60 10 Pond Pit Privy or Vault Privy (4X2) 50 10 25 15 10 to 25 10 - Septic Tanks, Treatment (2) (4)(2) (1) 50 10 - Plants, Dosing Tanks, Vaults 50 10 25 5 10 10 Building Sewer or (2)(4) (4)(2) (4) (2)(41 (4) (2)(4) (2)(4) Effluent Lines 50 10 25 0 10 t0 50 10 - '1 geological or other cmditions cribed. Where sol eo n an the physical features deo . B B NOTE: The minimum distances shown above shall be maintained between the system components d p y to accordance with the authority Water Quality Control Commission ursuan t to C.R.S. 25-8-2D6tY h local board of health or 6 the We woman[ realer distances may be aired b the o Q ty P .g Y 9 Y Y t stem ofnearb [res. For d into areas of the too s n watertight should not extend Y Y prescribed by law and rules and regulations implemental of said section. Components which are of repair or upgrading of existing systems where the size of lot precludes adherence to these distances, repaired facility shall not be closer to water supply components than tle existing facilities. recycling (p Distance shown shall not apply to treatment plants or effluent lines where is permitted. (2) Crossings or encroachments may be permitted at the points as noted above provided that the water conveyance pipe Is encased for a minimum distance of ten (ID) feet on each side of the crossing. A length of pipe shall be used with a minimum Schedule 40 rating of sufficient diameter to easily slide over andcompletely cncas; the water conveyance. Ridged end caps of at least Schedule 40 rating must be glued or secured in a watertight fashion to the ends of the encasement pipe. A hole d sufficient size to accommodate the pipe shall be drilled in the lowermost section of the ridged cap so that the conveyance pipe rests on the bottom of the encasement pipe. The area in which the pipe passes through the eralcaps shall be sealed with an approved underground sealant Compatible with the piping used, (3) Add 8 feet additional distance for each 100 gallons per day of design flow over 1000 gallons per day as specified in the table, unless it can be demonstrated by i registered Professional Engineer or Geologist that a mechanical or refund barrier will prevent contamination. (4) Encroachments may be permitted provided the water or wastewater conveyance pipe is encased as in (2) above, specified in the table. 0 GRAPHIC SCALE ( IN FEET ) 1 inch = 30 ft. REMOVABLE PVC INSTALL MARKER IS TO BE BURIED FINISH GRADE -\ 4" COUPLING 4" SEWER LINE 9 I � 'ING CABIN 7 C7 DARATE ISDS ° 120 GRADE EXISTING GROUND r NATURAL BACKFILL r12" MIN, COVER 1 36" MAX. COVER ' -6-MITI NG CABIN SEPARATE IDS \ \ 04 NATURAL GROUND -/ TYPICAL CROSS SECTION - NITS. T l - REMOVABLE CAP 4 - 1/2" VENT HOLES 4" 0 -CUT HOLE IN TOP OF SOLID PIPE INFILTRATOR UNIT FOR 4" RISER INSTALLATION OF INSPECTION WELL PIPE 4" 45' SWEEP BEND COUPLING} MINI1. 1' 1 o� 4" x 4" x 4"_/ PVC WYE CLEAN OUT ASSEMBLY SEWER CLEAN OUT DETAIL N.T.S 12" Z/ O 4" 0 PERFORATED PIPE O 36" INSPECTION WELL DETAIL N.T.S. LEGEND 11 StO-- -- EXISTING MINOR TOPOGRAPHY -95- EXISTING MAJOR TOPOGRAPHY 99.00 PROPOSED MINOR TOPOGRAPHY $,QO PROPOSED MAJOR TOPOGRAPHY EXISTING GRAVEL DRIVEWAY PROPOSED GRAVEL DRIVEWAY EXISTING LEACHFIELD EDGE OF DRIVEWAY ® EXISTING CULVERT ISDS SETBACK PROPERTY BOUNDARY CABIN PROPOSED BEDROOMS TANK NUMBER C1 1 4 I 2 3 C3 2 3 4 -C- 4 1 -a'0& 400 $69 700 48& 876 1 EW 1000 C8 1 4 C9 2 3 C13 2 - 4 �: rSrlir,dp ktl �V' * G� W� F* �nU U t O ID x W FW WS 7s L I" EW a WZW >Z •i i Sa O m U r xa� SITEAa , r" '.J 4 - LEGEND 11 StO-- -- EXISTING MINOR TOPOGRAPHY -95- EXISTING MAJOR TOPOGRAPHY 99.00 PROPOSED MINOR TOPOGRAPHY $,QO PROPOSED MAJOR TOPOGRAPHY EXISTING GRAVEL DRIVEWAY PROPOSED GRAVEL DRIVEWAY EXISTING LEACHFIELD EDGE OF DRIVEWAY ® EXISTING CULVERT ISDS SETBACK PROPERTY BOUNDARY CABIN PROPOSED BEDROOMS TANK NUMBER C1 1 4 C2 2 3 C3 2 3 4 -C- 4 1 -a'0& 400 $69 700 48& 876 1 EW 1000 C8 1 4 C9 2 3 C13 2 - 4 TANK PROPOSEDAVERAGE BEDROOMS OW d PEAK FLOW (gpd) 1.75 PEAK TANK STORAGE 30 HR d TANK SIZE GALLONS 3 -9- 6 1 ;JO& 600 15751050 1-9891313 2000 1500 4 -C- 4 1 -a'0& 400 $69 700 48& 876 1 EW 1000 TOTAL -17-10 i-7601000 E975 1750 O� �0 NOTE: RECOMMEND MINIMUM BURY DEPTH OR SLIGHT MOUND TO ACHIEVE REQUIRED COVER. �u APPROXIMATE FIELD LOCATION RECORD DRAWING NOVEMBER 28, 2005 SECTIONS 20 & 21, "I'N I� S��RANGE 83 W. 6TH P.M, Y VSCALE: 1" - 2000' P 0EI� ABSOFFI N TFIENCH NOTES 1. ABSORPTION LATERALS SHALL NOT EXCEED 100 -FEET IN LENGTH. 2. THE BOTTOM OF ABSORPTION BED SHALL BE LEVEL. 3. DRAINAGE SWALES ARE PROVIDED ABOVE AND AROUND TRENCHES, AS NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING ABSORPTION AREA. 4. INSTALL INFILTRATOR IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 5. NO EXCAVATION OF ABSORPTION FIELD IS DONE DURING WET WEATHER AND USE OF RUBBER TIRE VEHICLES OVER ABSORPTION AREA IS PROHIBITED 6. BOULDERS EXISTING WITHIN THE ABSORPTION BED SHALL BE EXCAVATED AND BACKFILL SHALL CONSIST OF ONSITE SELECT OR PIT -RUN MATERIAL. 7. EQUILATERAL DISTRIBUTION SHALL BE USED WITHIN ABSORPTION BED. INSTEAD OF EQUILATERAL DISTRIBUTION TO INCREASE SETTLING TIME AND PROTECT THE BACTERIAL BIO -MAT, CeetAL 1. ALL CONSTRUCTION SHALLBE IN ACCORDANCE WITH THE PITKIN COUNTY REGULATIONS OF INDIVIDUAL SEWAGE DISPOSAL SYSTEMS, EVEN THOUGH ALL SUCH REQUIREMENTS ARE NOT SPECIFICALLY NOTED ON THE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS. 2. CALCULATION SUMMARY: 9 BEDROOMS (SEASONAL USE CABIN) * 2 PERSONS/BEDROOM * 50 GALLONS/PERSON/DAY IS: 900 GPD = AVERAGE DAILY FLOW DESIGN FLOW = 1.75 * AVERAGE = 1575 GPD (Q) Q * I DAY/24 HRS * 30 HRS = 1969 GPD INSTALL ONE 2,000 -GALLON TANK WITH BAFFLE ***INSTALL 810 -FILTER IN SEPTIC TANK OUTLET*** A = 0 4T Q=MAXIMUM FLOW 6- t=PERCOLATION RATE = 10 min./in. 1750 3/TO ee 1107 USE STANDARD CHAMBER INFILTRATOR UNITS IN BED CONFIGURATION: 30% REDUCTION (1217 SF * 0.70) 0 15.5 S.F./UNIT, 50 UNITS REQUIRED. 3. CLEAN OUTS ARE REQUIRED AT ALL BENDS AND AT LEAST EVERY 100 FEET ALONG THE HOUSE SEWER. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL WATER TIGHT COMPONENTS, PRIOR TO THE ABSORPTION AREA, 5. TOPSOIL COVER MAY BE VARIED (WITH 1 FOOT MINIMUM) TO ALLOW LANDSCAPING. 6. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS TO WITHIN ONE-HALF FOOT OF FINAL GRADE. 7. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED. 8. PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM ABSORPTION FIELD AREA USING DRAINAGE SWALES AS NECESSARY. 9, SOILS AND PERCOLATION INFORMATION PROVIDED BY H.P GEOTECH, INC., PERCOLATION INFORMATION PROVIDED VERBALLY WITH REPORT TO FOLLOW. 10. THIS DRAWING DOES NOT CONSTITUTE AN ISDS PERMIT. PERMIT MUST BE OBTAINED FROM APPROPRIATE CITY OR COUNTY OFFICIALS. ENGINEER MUST OBSERVE CONSTRUCTED SYSTEM BEFORE BACKFILL 11, THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM. 12. SITE PLAN INFORMATION PROVIDED BY THE CLIENT. 13. INSTALL BLUEBOARD INSULATION OVER SEWER PIPE WHEREVER DEPTH IS LESS THAN 5.0 FEET, 14. THE ENGINEER SHALL BE CONTACTED FOR SITE INSPECTION PRIOR TO BACKFILLING OF SYSTEM COMPONENTS. 15. THIS SYSTEM IS DESIGNED FOR TYPICAL DOMESTIC WASTES ONLY. HOME OWNER IS RESPONSIBLE FOR TIGHT PLUMBING FIXTURES. I.E. HISSING TOILETS AND RUNNING WATER IS NOT ACCEPTABLE AND MAY OVERLOAD THE SYSTEM. 16. HIGH COUNTRY ENGINEERING RECOMMENDS CONCRETE SEPTIC TANKS OR EQUIVALENT. 17. THE ISDS SHALL BE LOCATED MORE THAN 148' FROM EXISTING WELLS. 18. ALL EXISTING SEPTIC TANKS CURRENTLY PROVIDING SERVICE TO THESE CABINS WILL BE FILLED IN OR REMOVED TO COMPLETE TANK ABANDONMENT. 19. ALL EXISTING LEACH FIELDS CURRENTLY PROVIDING SERVICE TO THESE CABINS WILL BE ABANDONED, 20. ALL WATERLINE SLEEVES SHALL BE SCHEDULE 40 PVC PIPE OF SUFFICIENT SIZE TO ALLOW FOR CONSTRUCTABILITY. 21. THIS SYSTEM IS DESIGNED AS AN INFILTRATION BED UTILIZING 50 STANDARD INFILTRATOR UNITS. THE INFILTRATOR UNITS SHALL BE CONNECTED WITH MANIFOLD PIPING AT EACH END TO PROVIDE EQUILATERAL DISTRIBUTION. 001> QQ Qa� U UhrC O LL O In boN2 a ZL)NZ 0 �oO)$ U] SW $ III Z op t� 1D J 0 a Z 0 W X Is 5- o L OD a V O j� V In 9 m Ln Q r..T ZW N IL U) *�DN1 IL N0 0) L6 00 IN W O� �0 Z a q ME"li* L' J LL Z G� W� F* �nU U t O ID x W FW WS 7s L I" EW a WZW >Z •i i Sa O m U r xa� SECTIONS 20 & 21, "I'N I� S��RANGE 83 W. 6TH P.M, Y VSCALE: 1" - 2000' P 0EI� ABSOFFI N TFIENCH NOTES 1. ABSORPTION LATERALS SHALL NOT EXCEED 100 -FEET IN LENGTH. 2. THE BOTTOM OF ABSORPTION BED SHALL BE LEVEL. 3. DRAINAGE SWALES ARE PROVIDED ABOVE AND AROUND TRENCHES, AS NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING ABSORPTION AREA. 4. INSTALL INFILTRATOR IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 5. NO EXCAVATION OF ABSORPTION FIELD IS DONE DURING WET WEATHER AND USE OF RUBBER TIRE VEHICLES OVER ABSORPTION AREA IS PROHIBITED 6. BOULDERS EXISTING WITHIN THE ABSORPTION BED SHALL BE EXCAVATED AND BACKFILL SHALL CONSIST OF ONSITE SELECT OR PIT -RUN MATERIAL. 7. EQUILATERAL DISTRIBUTION SHALL BE USED WITHIN ABSORPTION BED. INSTEAD OF EQUILATERAL DISTRIBUTION TO INCREASE SETTLING TIME AND PROTECT THE BACTERIAL BIO -MAT, CeetAL 1. ALL CONSTRUCTION SHALLBE IN ACCORDANCE WITH THE PITKIN COUNTY REGULATIONS OF INDIVIDUAL SEWAGE DISPOSAL SYSTEMS, EVEN THOUGH ALL SUCH REQUIREMENTS ARE NOT SPECIFICALLY NOTED ON THE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS. 2. CALCULATION SUMMARY: 9 BEDROOMS (SEASONAL USE CABIN) * 2 PERSONS/BEDROOM * 50 GALLONS/PERSON/DAY IS: 900 GPD = AVERAGE DAILY FLOW DESIGN FLOW = 1.75 * AVERAGE = 1575 GPD (Q) Q * I DAY/24 HRS * 30 HRS = 1969 GPD INSTALL ONE 2,000 -GALLON TANK WITH BAFFLE ***INSTALL 810 -FILTER IN SEPTIC TANK OUTLET*** A = 0 4T Q=MAXIMUM FLOW 6- t=PERCOLATION RATE = 10 min./in. 1750 3/TO ee 1107 USE STANDARD CHAMBER INFILTRATOR UNITS IN BED CONFIGURATION: 30% REDUCTION (1217 SF * 0.70) 0 15.5 S.F./UNIT, 50 UNITS REQUIRED. 3. CLEAN OUTS ARE REQUIRED AT ALL BENDS AND AT LEAST EVERY 100 FEET ALONG THE HOUSE SEWER. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL WATER TIGHT COMPONENTS, PRIOR TO THE ABSORPTION AREA, 5. TOPSOIL COVER MAY BE VARIED (WITH 1 FOOT MINIMUM) TO ALLOW LANDSCAPING. 6. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS TO WITHIN ONE-HALF FOOT OF FINAL GRADE. 7. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED. 8. PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM ABSORPTION FIELD AREA USING DRAINAGE SWALES AS NECESSARY. 9, SOILS AND PERCOLATION INFORMATION PROVIDED BY H.P GEOTECH, INC., PERCOLATION INFORMATION PROVIDED VERBALLY WITH REPORT TO FOLLOW. 10. THIS DRAWING DOES NOT CONSTITUTE AN ISDS PERMIT. PERMIT MUST BE OBTAINED FROM APPROPRIATE CITY OR COUNTY OFFICIALS. ENGINEER MUST OBSERVE CONSTRUCTED SYSTEM BEFORE BACKFILL 11, THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM. 12. SITE PLAN INFORMATION PROVIDED BY THE CLIENT. 13. INSTALL BLUEBOARD INSULATION OVER SEWER PIPE WHEREVER DEPTH IS LESS THAN 5.0 FEET, 14. THE ENGINEER SHALL BE CONTACTED FOR SITE INSPECTION PRIOR TO BACKFILLING OF SYSTEM COMPONENTS. 15. THIS SYSTEM IS DESIGNED FOR TYPICAL DOMESTIC WASTES ONLY. HOME OWNER IS RESPONSIBLE FOR TIGHT PLUMBING FIXTURES. I.E. HISSING TOILETS AND RUNNING WATER IS NOT ACCEPTABLE AND MAY OVERLOAD THE SYSTEM. 16. HIGH COUNTRY ENGINEERING RECOMMENDS CONCRETE SEPTIC TANKS OR EQUIVALENT. 17. THE ISDS SHALL BE LOCATED MORE THAN 148' FROM EXISTING WELLS. 18. ALL EXISTING SEPTIC TANKS CURRENTLY PROVIDING SERVICE TO THESE CABINS WILL BE FILLED IN OR REMOVED TO COMPLETE TANK ABANDONMENT. 19. ALL EXISTING LEACH FIELDS CURRENTLY PROVIDING SERVICE TO THESE CABINS WILL BE ABANDONED, 20. ALL WATERLINE SLEEVES SHALL BE SCHEDULE 40 PVC PIPE OF SUFFICIENT SIZE TO ALLOW FOR CONSTRUCTABILITY. 21. THIS SYSTEM IS DESIGNED AS AN INFILTRATION BED UTILIZING 50 STANDARD INFILTRATOR UNITS. THE INFILTRATOR UNITS SHALL BE CONNECTED WITH MANIFOLD PIPING AT EACH END TO PROVIDE EQUILATERAL DISTRIBUTION. 001> QQ Qa� U UhrC O LL O In boN2 a ZL)NZ 0 �oO)$ U] SW $ III Z op t� 1D J 0 a Z 0 W X Is U � o J OD V O j� V In 9 m Ln Q m � Cr ZW N IL U) *�DN1 IL N0 0) L6 U � o Z OD V U j� V 00a Up 3(I ZW N IL WZ *�DN1 IL N0 1.1� W Z 0 00 IN W O� �0 Z a q ME"li* L' J LL Z G� W� F* �nU U 1p O ID x W FW WS 7s L I" EW a WZW >Z wa Sa O m U xa� H, , OQ I-� ULn Ld0 Z._ d 0 U Z _j WZ °0oo _jj Z d W Z - Z G� OQ U PROJECT NO. 2041709.00 0218 ISDS