Loading...
HomeMy WebLinkAboutpitkin.eh.264306202005 (1997)Document Layout (From Most Recent to Oldest Permit) Permit Application Log Sheet/Notes & Photos Communications. As -built Design Engineer Design Soil Information Water Permit & Information Second System on property Third System .etc. Floor Plans Please See Building and Land Use Approvals Files for additional information. ' ASPWITKIN ENVIRONMENTAL HEALTH DEPP ENT APPL N FOR INDIVIDUAL SEWAGE DISPOEWSTEM 130 S. Galena St.. Aspen Colorado 81611 Phone 970-920-5070/Fax 970-920-5039 Permit# `70/2— Parcel ID# 3 —Atk —402—t Permit For. New Installation (k) Repan( ) Remodel( ) Emergency use( ) Name of OWNER TAOL AAA GINA SAnaetsort Street Address OO�AQ Ale Ai Ey LAPiE SAllamASs� CO /r�q��.54 Owner's Mailing Address 0040 AREIA4 1 WE JNc I.(NMASSr Business Phone 917' 03_1 Home Phone 92 3 - Y539 Legal Description: Lot b ,Block C1RC1E.Subdivision Size of lot: 1_ acres Type of propo's'ed structure: DdFLE)C Size of bldg. envelope: e1 A em Total areafting space (sq. ft): 13-14 # of Bedrooms. offices and similar size rooms. 3 yt ) Caretaker Unit Attached ( )Detached (1.60) Total area living space of caretaker und(sq ft.) ( 2 ) If of Bedrooms, offices and similar size rooms Primary Contact Person SP -FF (;,FeFJA7- JTOTS,NAN 6eC6IAZ, WC_ Contact Mailing Address 3m.4e�WAY 82- Sy V)mos G0 glb.��] Business Phone: 9.23-2%3 4 Cell Phone. .379-7301 Fax q;Z3-0647 Water(X1Pnvate well ( )Spring ( )Stream ( ) Community/Pubic (Name of System) Is Proof of Adequate Water Attached (Required) ? (yJ Yes ( ) No (A water quality test and well pump test of approval letter from community system) Has this project been approved by Pilkin County ? (XI Yes ( ) No Is a copy of the floor plan attached ( Require ) ? (A)Yes( ) No Is a copy of the site plan attached Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information is true and accurate and that I have provided we and accurate infonnalion on locations of all existing and proposed walls, contour intervals. buildings, property Ines, ditches, slopes, waferfines, springs, suction or irrigation lines. drinking water ciders. drain tiles, irrigation ditches. lakes, water counties. steamei floodplans, dry gulches, and existing septic systems. I acknowledge that any false or incomplete information will invalidate the application and any subsequent perml Issuance of the pertno does not imply the approval of any other permit required for construction pursuant to Pitkin County codes. No construction, may be undertaken until all approvals and Permits have been obtaineo. The owner assumes all respons billies in case of failure or inadequacy of this system. J Signature of applicant ;l�Aj %/1G�67iGi.✓//�//y/yGrG.fs�.t� Date ----------------------- __------______---_______ _____ ______-_ For department use below wesign untieria Qu 5v5kej m ii i /01, Perc Rate /& min per inch Profile Hole Depth $ / feet Septic tank capacity: ZfOCJD gallons Absorption area. PfffoQ sq. ft. )�r)Ds� 3T a6soi�oNaracr re$��iirdGd/gip No 78i%G/�<+io µH:Ts )f Gr5 ®o/ o4 91:0e � , y'gvoG, &/, 349/-S d144771) cc S /yy S`/ I/V�iG%Aiar c#.✓/T , /rrry/irrm -�.o/d s;7� /w� :// 60 98og$ � Tf 7trayr--c / s c- cL,c,/vice %%ice w.// 6e 4 GT�'6�di-oo�, /ti %ho74l�jLi/L�� nfirvillsHih i 4Mr4 SiZ-B SG�AP// 6e 25_oo9gG.d,Sch�ii�ja%✓jTo czn/absey®Tio�4.eaof/6$O51-P?&3u, o r 3 0 % ;,+;///!e,�Sf 47- G i /µSi17i, /...:TS _ 5&—e Gwa'lTasr iY vs, -r —7, ff cnimo,,..;/ d ar♦�vt y/2/ An Inspection is required prior to backfill of any component of the distribution system. `&q4-4;rB/o4 Design by Engineer Required ? ( ) Yes 91No All plans and spedfications of the engineer must be followed. Any changes must be approved by the Aspen/Pitkin Envirommntal HealtInDepartmenlfin waling and,0e engineer must certify the final installation to the Environmental Health Department in writing. / / �/ Permit approval by: X/Lf//ZS���,i�z�fs C Date %f� Duins and spermscations of the proposed individual sewage disposal system have been reviewed and are considered satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin County ISDS Regulation n effect at the time of issue. This permit becomes invalid 6 months from the date Tat the permit was issued unless system construction has commenced or an extension has been approved in writing by the Department, As -Built drawings must be included with this permit before the final approval will be issued. Installer. �a-4-2-Q-1 Receipt e Site Plan -Q Date received j�� Floor Plan 1--YYI w Received by ✓ Comm Dev Approval t� Well Permit and ✓ Soils Test Z Water Quality Test or z f Date Info Complete �r�Pv✓7 ✓ Water System Letter Final Insp Requested 1 J 9 Final Inspection Approval: Date: APeeo tans ASP§MTKIN ENVIRONMENTAL HEALTH DEPA ENT } APPL N FOR INDIVIDUAL SEWAGE DISPOSWSTEM 13U S. Galena St., Aspen Colorado 81611 /� Phone xx e 970-920-5Oi0/Fa970-920-5039 Permit # / 7,012 Parcel ID # 2&11+3 - 2i -*Z- 605- Permit For: New Installation (k Repair( ) Remodel ( ) Emergency Use( ) Nameof OWNER Ago GINA &A'Jusm�r Street Address 00 NEY N SabtU SS CO T1 Owaee's Mailing Atldress R SIVO 6.Y Business Phone: �7- 0331 Home Phone: .2 J Legal Description. Lot 5_ .Block . 00111&k/N.YIY1[Ttie eiRaa6,Subdivision Size of lot 3 acres Type of proposed structure: DOFLEX Size of bldg. envelope: .91 Aso Total arealliving space (sq. ft): 13-1 8 of Bedrooms, offices and similar size rooms: 3 Caretaker Unit: MAttached Detached 460 Total ama/iivim space of caretaker units ft.) I K of Bedrooms offices and similar size rooms Primary Contact Person .14a Q05BIl Z STtrSMAN49C1Ce 7- Wc._ Contact Mailing Address 3,I,?7& "OV g2 Stile s"014 i r %o 9/esy Busness Phone -4.23-2%.34 Cell Phone 3%9'71 Fax: 72,3'0497 Water(Xprivstewell ( )Spring ( )Stream ( ) Community/Public (Nam of System) Is Proof of Adequate Water Attached (g@g tr ) ? (y4Yes ( )NO (A water quality test and well pump test or approval letter from community system) Has this project been approved by Pitkin County? W Yes ( ) No Is a copy of the Boor plan attached (Reuulred) 7 (A) Yes ( ) No ? QQ Yes ( ) No Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information is true and accurate and that I have provided We and acwrale information an locations of all existing and proposed wells, contour intervals. buildings, property lines, ditches, slopes, waterlines. springs, suction or irrigation Imes, drinking water cisterns, drain tiles, irrigation ditches, lakes, water courses, streams, noodplains, dry gulches, and existing septic systems. I acknowledge that any false or incomplete information will invalidate the application and any subsequent patina. Issuance of the permit does not imply the approval of any other permit required for construction pursuant to Pakln County codes. No construction may be undertaken until all approvals and permits have been obtained The owner assumes all respons'to If as In case of failure or inadequacy of this system. A 2 /7 Signature of applicant A+/} dk 1i'2 SEA/1/A(G 4, 0, YiU"4"J <//y^Y//cG.se.� Date ------------------------- ------- - ------------------------------------------- For department use below PERMIT FOR INDMDUAL SEWAGE DISPOSAL SYSTEM U631 n - r System 1 rs' Perc Rate ` min per inch Profile Hole Depth S feet Septic tank capacity: 20 DO gallons Absorption area: III[Alli sq. ft. 1,�//Ds� absor�on�area re$�,iirdw�73,.vo si/tidvo]:o�v, 78i%GTir /y+'i'Ts i dvseB i ✓Placa e f ai��G, L✓,7� aD /'s discTaxJ tc -W Sy /�v¢i l Tr.��r u.✓iT , in:.vlms�m ���/d S�ZG wi/! 6G 980A$:6�7-7 r£ 7A•r+-- / s el- GlyyyycE %%ice w.//,6� 4 G'A'6o�ioonr 7A� 7Jt o-fi+�lAar� piNYimNir, TOiYy, 5/71B 6e 25-P R 9gG.41, s 51-F`7 6-73 or 3,09, re�sa ons �orva�i G7i^rs �dr� /../ I e�ui /IG+Ssgi�i G k.�iG77 y An inspection is required prior to backfill of any component of the distribution system. -S-r'o ' Z&- d -J;7;l Design by Engineer Required ? ( ) Yes 9PNo All plans and specifications of the engineer must be followed. Any changes must be approved by the AspenlPitkin Envirommntal Health partment in writing and a engineer must certify the final installation to the Environmental Health Department in Date �1� writing. `7� /� -7 Permit approval by: i' m -'arts and specifications of the proposed Individual sewage disposal system have been reviewed and are considered satisfactory. Permission is hereby granted to the owner or rte agent to perform me work indicated in accordance with the Pitkin County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date Tat the permit was issued unless system construction has commenced or an extension has been approved in writing by the Department. As -Built drawings must be included with this permit before the final approval will be issued. Installer: Receipt# Date received Received by 0 Final Inspection Approval: Site Plan ✓ Wel( Permit and ✓ Soils Test k,� Floor Plan Water Quality Test or 9 Date Info Complete 1 r'4DPH1 ✓ Comm Dev Approval ✓ Water System Letter Final Insp Requested APEHa I(ax /00o � -tA�. 4-41 g,Q,,... Q„ "q. A-� I )/3b/'Y7 LIOIL � - o �; < , -� n an / Pitkin Environmental Health Depart Contact Log Sheet Name: EO/J t- a R - Parcel lD#: Address: ;t S' -&,53Y f 13 - 074 Date Person SpokervTo Comments / Action to be Taken Initials M oL -- ��aa- r t� 7o I 111111111111111111111111111 IIIII�i11 III 111111111 IN 446611 09/01/2000 11:20A MEMO DAVIS SILVI 1 of 1 R 5.00 D 0.00 N 0.00 PITKIN COUNTY CO To: Paul & Gina Samuelson 0040 Arbaney Lane Snowmass. CO 81654 February 22, 2000 Re: Lot 5, Double X Quarter Circle Subdivision; permit #97012 Dear Mr. & Mrs. Samuelson: 4? 3Vi3-00a -0,aCb5 6 ASPEN • PITKIN ENVIRONMENTAL HEALTH DEPARTMENT A permit for an individual sewage disposal system (ISDS) was issued for the above noted property on 4/4/97. Without an I51)5 permit being issued, we would not have been able to sign off on your building permit to build your home. Your home has been completed and your Certificate of Occupancy (CO) is waiting to be signed. Pitkin County Environmental Health cannot sign your CO without first finaling your I5D5 permit. You must have your ISD5 permit finaled by June 15, 2000. The requirements that must be met prior to your I5DS being finaled are that your driveway be moved from over the I5D5 field and that Pitkin County Environmental Health receive an as -built drawing of your system installation by your installer, 5tutsman- Gerbaz. You should contact your installer and have them complete your as -built drawing. You have been previously notified that the driveway must be moved so that it is not over your I5D5 field. As is noted in the Pitkin County Individual Sewage Disposal System Regulation, for the type of system that you have, no driveway may be on top of a leaching area. There are good reasons for this. Driving on top of soils compacts them, making them less effective in absorption. Driving on system components can damage them. Either one or both of these factors can cause a system to fail. Our main concern is the protection of groundwater quality, but also the expense to the homeowner should a repair or replacement be necessary. Our efforts to work with you to see this I5DS permit to completion have failed. As was previously stated, we must be able to final your ISDS permit by June 15, 2000. If the permit is not finaled by this date, we will record a copy of this letter against your property as public notice of non-compliance. In addition, because there are public health concerns due to your lack of compliance, we, may also seek injunctive relief through the courts. Should you have questions regarding this issue, please don't hesitate to contact this department. Since Th/ 5 DunloG^ Director, Pitkin County Environmental Health Department CC: Pitkin County Attorney Printed on Recycl Par 130 Som GALENA STREET ASPEN, CoLoRAoo 81611-197 . PHONE 970.920.5070 FAx 970.920.5197 L_— To: Paul & Gina Samuelson 0040 Arbaney Lane 5nowmass. CO 81654 February 22, 2000 Re: Lot 5, Double X Quarter Circle Subdivision; permit #97012 Dear Mr. & Mrs. Samuelson: 77 ASPEN • PnxN ENVIRONMENTAL HEALTH DEPARmw A permit for an individual sewage disposal system (ISDS) was issued for the above noted property on 4/4/97. Without an I5D5 permit being issued, we would not have been able to sign off on your building permit to build your home. Your home has been completed and your Certificate of Occupancy (CO) is waiting to be signed. Pitkin County Environmental Health cannot sign your CO without first finaling your ISD5 permit. You must have your I5D5 permit finaled by June 15, 2000. The requirements that must be met prior to your I505 being finaled are that your driveway be moved from over the I5D5 field and that Pitkin County Environmental Health receive an as -built drawing of your system installation by your installer, Stutsman- Gerbaz. You should contact your installer and have them complete your as -built drawing. You have been previously notified that the driveway must be moved so that it is not over your I5D5 field. As is noted in the Pitkin County Individual Sewage Disposal System Regulation, for the type of system that you have, no driveway may be on top of a leaching area. There are good reasons for this. Driving on top of soils compacts them, making them less effective in absorption. Driving on system components can damage them. Either one or both of these factors can cause a system to fail. Our main concern is the protection of groundwater quality, but also the expense to the homeowner should a repair or replacement be necessary. Our efforts to work with you to see this I5D5 permit to completion have failed. As was previously stated, we must be able to final your ISDS permit by June 15, 2000. If the permit is not finaled by this date, we will record a copy of this letter against your property as public notice of non-compliance. In addition, because there are public health concerns due to your lack of compliance, we. may also seek ajunctive relief through the courts. %iould you have questions regarding this issue, please don't hesitate to contact this department. Sincerely, Thomas S. Dunlop Director, Pitkin County Environmental Health Department CC: Pitkin County Attorney Printed on Rec cled PaQ[r L 130 Soum GALENA STREET - ASPEN, COLORADO 81611-1975 PHONE 970.920.5070 FAx 970.920.5197 PMW on Rm,W Paper C, ■ C, are items 1, 2, and 3. Also complete itt if Restricted Delivery is desired. ■ Print your name and address on the reverse so that we can return the card to you. ■ Attach this card to the back of the mailpiece, or on the front if space permits. 1. Arrvle Addressed to: A. B. C. Signal X ❑ Agent ❑ Accra D. Is delivery address different from item 1? ❑ Yes If YES, enter delivery address below: ❑ No 3 1 3. Service Type �S ✓ ��I-�s' ck Certified Mail ❑ Express Mail ❑ Registered ❑ Return Receipt for Merchandise Q O l a > -14 $b-1 01 nsured Mail ❑ C.O.D. 4. Restricted D Ivairyt Xxba Fee) ❑ Yes 2. Article Number (Copy from service label) 7— t. -IE> —113 lto-a PS Form 3811, July lggg Dom, m g 0 U- W a Z 218 713 163 ea US Postal Service Receipt for Certified Mail No Insurance Coverage Provided. Do not ese Inr u.a rcee .e..,,...,,� 1' a -d tYt0, street d tiartber a-� Post Office, Sine, 8 ZIP Cade 011 Postage S 3 Certified Fee O Special Delivery Fee Renncted Delivery Fee Relum R to Posta*A Fees ar MM 0 If 4 X -Sender: rickm@comdev.aspen.co.us Date: Thu, 03 Apr 1997 14:43:05 -0700 To: Tom Dunlop <tomd@comdev.aspen.co.us> From: Rick Magill <rickm@comdev.aspen.co.us> Subject: Re: Paul Samuelson Building Envelope Tom, Based on your representations regarding the Samuelson ISDS application and my understanding of the property, I feel that additional Planning Office review is not necessary for the installation of the septic system in the area indicated by you. The area proposed for the septic system is relatively flat (slopes of less than 15%) and is free of any other 1041 Environmental Hazards. Rick Magill Senior Planner Aspen Pitkin Community Development Department At 02:33 PM 4/3/97 -0700, you wrote: >Rick, >As per our discussion on 4/3/97 concerning the Paul Samuelson ISDS >application and proposed Building permit, the following was agreed to by you >as presented by this office. >The Aspen/Pitkin Community Development Department is requested to approve >the installation of an individual sewage disposal system outside the >building envelope on Lot 5, Double X Quarter Circle Subdivision, commonly >know as 0040 Arbany Lane, Snowmass, Colorado. This request for >consideration is made by the Aspen/Pitkin Environmental Health Department. >Further, this request for approval can be made administratively without >formal action of the BOCC as per your comment to me. >The property in question was approved as a subdivision by the BOCC in >Resolution No. 80-98. >The reason for this approval is based on required setbacks defined in the >Pitkin County Individual Sewage Disposal System Regulation, and the fact >that Mr. Samuelson cannot physically fit his water well, septic system and >house within the defined envelope. Also, the requirement that all utilities >be located within a defined building envelope was implemented approximately >15 years after this subdivision was approved. >>From the public health perspective it will be more protective of ground >water and drinking water if the ISDS is installed at the location shown on >the map reviewed with you on this date. >If this representation of our conversation is accurate, please acknowledge �i ,Printed or Tom Duniop <tomd@comdev.aspen.co.us> 3 >by return e-mail. This communication will become a permanent part of the >ISDS record for this specific property. >Tom dunlop >Tom Dunlop >Environmental Health >920-5073 lFrInted for TOM DIMIOP <tomd@comxIev.aspen.co.u9> ASPEN/PITIRN ENVIRONMENTAL HEALTH DEPARTMOV ISDS DESIGN REQUIREMENTS DEPARTMENT USE ONLY Name Paul Samuelson Permit#y7d/Z Parcel ID # House Siz 6 (75 gpd, 100 gpd, or 130 gpd) 100 Number of Bedrooms, Lofts, Offices, Similar Rooms, Main House 4 Number of Bedrooms, Lofts, Offices, Similar Rooms, Caretaker unit 2 Average Daily Waste Flow 1 200 900 # bedrooms X 2 people/br X 75 State Review Required? no Perc Rate 16 (T) Design Flo w (Q) = # bedrooms X 2 people/bedroom X gpd X 1.75 Q= 2100 Absorption Area (A= Q/5 X SART) A = 1680 sq. ft. of absorption area required 93 infiltrator units without reduction A maximum 30% reduction is allowed for use of deep gravel or gravelless chambered system. 1176 sq.ft. with reduction 65 infiltrator units with reduction Type of system: DAbsorption trenches DAbsorption bed D Gravelless chambers DDry well DSeepage Pit DPumping Chamber Is an Engineer -Designed System required? no XX yes reason: Minimum tank capacity —al]Wgallons Coll z 55)ep SETBACK FROM WELL # of feet = 188 Remember: 8 feet of additional distance for each 100 gallons/day of design flow over 1,000 gallons/day should be added unless an RPE can verify that it is not necessary to prevent contamination. APPROVED FOR ISSUE DATE:/'�"/� % SYSTEM INSTALLED BY: DATE OF FINAL INSPECTION REQUEST: FINAL INSPECTION BY: 10 Printed on Recycled Paper DATE: X -Sender: rickm@comdev.aspen.co.us Date: Thu, 03 Apr 1997 14:43:05 -0700 To: Tom Dunlop <tomd@comdev.aspen.co.us> From: Rick Magill <rickm@comdev.aspen.co.us> Subject: Re: Paul Samuelson Building Envelope Tom, Based on your representations regarding the Samuelson ISDS application and my understanding of the property, I feel that additional Planning Office review is not necessary for the installation of the septic system in the area indicated by you. The area proposed for the septic system is relatively flat (slopes of less than 15%) and is free of any other 1041 Environmental Hazards. Rick Magill Senior Planner Aspen Pitkin Community Development Department At 02:33 PM 4/3/97 -0700, you wrote: >Rick, >As per our discussion on 4/3/97 concerning the Paul Samuelson ISDS >application and proposed Building permit, the following was agreed to by you >as presented by this office. >The Aspen/Pitkin Community Development Department is requested to approve >the installation of an individual sewage disposal system outside the >building envelope on Lot 5, Double X Quarter Circle Subdivision, commonly >know as 0040 Arbany Lane, Snowmass, Colorado. This request for >consideration is made by the Aspen/Pitkin Environmental Health Department. >Further, this request for approval can be made administratively without >formal action of the BOCC as per your comment to me. >The property in question was approved as a subdivision by the BOCC in >Resolution No. 80-98. >The reason for this approval is based on required setbacks defined in the >Pitkin County Individual Sewage Disposal System Regulation, and the fact >that Mr. Samuelson cannot physically fit his water well, septic system and >house within the defined envelope. Also, the requirement that all utilities >be located within a defined building envelope was implemented approximately >15 years after this subdivision was approved. >>From the public health perspective it will be more protective of ground >water and drinking water if the ISDS is installed at the location shown on >the map reviewed with you on this date. >If this representation of our conversation is accurate, please acknowledge lPrinted for TOM DUnIOP < o co ev.aspen.co.us> r, ►a >by return e-mail. This communication will become a permanent part of the >ISDS record for this specific property. >Tom dunlop >Tom Dunlop >Environmental Health >920-5073 Printed-forTom—Dunlop <tomd@c6xde_v.aspen.co.us> I" k,e* www W=P - min r7-1 i M 4y 8 , _ _a 1�+�.'r. r:N.H41lItIW"-- ��l-�pur).�r.byY'Y.My.uur 40"X - do owl • "f+ f k� • 4rIft ` Y s • "f+ . f J :8 - 43 YX its CA ►� { eip �#. 4{; . »�,. �l,;�4 ,. .. a ;�` -• ;4 r - . ..-�-�.,,r�P� . .00 ��< .�. ,, ,� ,� .. _�. fi _ :� rl�- .a Y�� ��-- f9 3 iJ :43 >�;; r+ 4 a�•�,,.. r� ya -. y" . r. i �_ i �i a yy ENGINEERS ' • SURVEYORS 40 (970) 925-6727 SC'1�i SE FAX (970) 925-4157 CORDONRDON MEYERM 3/ April 2, 1997 Mr. and Mrs. Paul Samuelson 0040 Arbaney Lane Snowmass, CO 81654 RE: 0040 Arbaney Lane, On -Site Wastewater System Location Dear Gina and Paul: P.O. Box 2155 Aspen, CO 81612 I am writing in follow-up to my discussions with Bob Nelson of NEWS, Ltd, regarding the location of an on-site wastewater disposal system (ISDS) for your proposed residence on Lot 5 of the Double X Quarter Circle Subdivision, addressed as 0040 Arbaney Lane. As Gina knows, I also attended a site visit on Tuesday, March 25th at the site with Gina, Bob, Jerry Gerbaz and Tom Dunlop of the Aspen/Pitkin Environmental Health Department. Based on Bob Nelson's Soils Evaluation and Percolation Test report for the site dated March 31, 1997, it appears that a conventional (non -engineered) ISDS will be feasible for the proposed residence. Based on Bob's initial percolation results and our observation of the profile pit during the site visit on March 25th, test holes were prepared somewhat deeper and re -tested, resulting in more consistent rates well within the non -engineered criteria of the Pitkin County regulations. Based on the site plan included as Figure 1 in Bob's report, two things are apparent with regard to the system layout; The system should not be located within the defined building envelope. Several constraints cause us to recommend that the system not be placed within the building envelope; a. The setback from the existing well within the property to the ISDS under County criteria could be up to 160 feet (our recommended system location will still encroach on this setback distance, more on this under item 2, below). The 160 foot setback effectively encompasses the entire building envelope. b. The logical location for an ISDS within the defined building envelope would probably be within the lower (northeasterly) corner of the envelope. From our site visit, it is apparent that the northeast corner of the envelope is within the irrigated meadow area fed by an irrigation ditch below the embankment to the east of the homesite. Locating an ISDS in an irrigated meadow area is problematic from an operational standpoint due to possibly fluctuating surface saturation or groundwater conditions and would require, at least, that a substantial area around and over the system be removed from irrigated use. I think you, as the property owners, and Pitkin County are probably in agreement that it would be undesirable to remove a portion of the meadow from irrigated use for ISDS purposes. This location, as noted above would still encroach on the well setback. 118 West 6th, Suite 200 • Glenwood Springs, Colorado • (970) 945-1004 April 2, 1997 Gina and Paul Samuelson Page 3 less than 160 feet from the well head as proposed. I should also note that care should be taken to route any substantive surface drainage around the final bed area. I hope these comments will be sufficient for issuance of your building permit. Feel free to contact me if I may provide additional comment or detail. Very Truly Yours, SCHMUESER GORDON MEYER INC. UlI lammond, P.E. , Aspen Office JHAh SISDS GORDON MEYER, April 2, 1997 Gina and Paul Samuelson Page 2 For perhaps the last 1 1/z years Pitkin County has been requiring that building envelopes be defined to include most disturbance areas including ISDS systems. Created in 1980, this lot clearly pre -dates the recent application of this policy and we would anticipate that placement of the ISDS outside the building envelope will not be an issue for the County in approving a building permit for the property. It is anticipated that the ISDS sytem will be located entirely below grade and revegetated upon completion. 2. The ISDS will need to encroach somewhat on the setback defined under the Pitkin County ISDS Regulations from the existing well. From Bob's report, the proposed residence comprises two units including a three bedroom main residence and a two bedroom attached caretaker unit. As attached units, it is my understanding that the Environmental Health Department views them in the aggregate as a five bedroom residence totalling 2,984 square feet. Due to the flow assigned to residences over 2,000 square feet under4he Pitkin County Individual Sewage Disposal System Regulation, at 100 gallons per capita per day, the combined structure would generate a theoretical design flow of 1,750 gallons per day (gpd). This design flow requires a setback from the wellhead of 160 feet under the requirements of Table II on page 24 of the County regulation "... unless it can be demonstrated by an RPE (Registered Professional Engineer) that this is not necessary to prevent contamination." Recommendation From my review of the design requirements for an ISDS for the 0040 Arbaney Lane property, we would recommend a generally conventional seepage type disposal system located in the area of the percolation and profile test holes north-northwest of the proposed home and building envelope. It is anticipated that sewage flow would be collected in the area of the northeast corner of the building footprint and routed to a septic tank downslope of the house. Treated effluent would then be lifted from the septic tank to the bed area by an effluent pump located in the second chamber of the septic tank (or in a separate vault). From our discussion of the bed area and configuration requirements, the required disposal area could encroach on the 160 foot distance by up to 35 feet leaving a minimum 125 foot setback from the wellhead. (It is worth noting that, while this reduced setback encroaches on the requirements under the Pitkin County Code, it would exceed the 110 foot setback defined under the recommended standard for well setbacks under the State ISDS guidelines.) Noting the relative location of the ISDS to the wellhead, which is hydraulically downstream relative to the river aquifer, and plotting a section through the proposed well and closest likely ISDS discharge, effluent projected at 450 will not intercept the projected water level (at T7 feet) upstream of the well. It is then anticipated that effluent would flow downstream, away from the well location. The distances from the ISDS bed area to the depth of the aquifer from which the water supply is to be drawn also render it unlikely that any pathogenic organisms or other pollutants would make it to the aquifer in any direction from the bed. In short, we feel that the site characteristics provide adequate demonstration that contamination of the on-site well will not be a concern due to the placement of a properly installed ISDS system GORDON MEYER, ASPEN/PlAENVIRONMENTAL HEALTH DEPARTMO ISDS DESIGN REQUIREMENTS DEPARTMENT USE ONLY �Z3-67�`f Permit# Name Lisa & Mark samuelson Parcel ID # House Size 2-6,000 (75 gpd, 100 gpd, or 130 gpd) Number of Bedrooms, Lofts, Offices, Similar Rooms, Main House 4 Number of Bedrooms, Lofts, Offices, Similar Rooms, Caretaker unit 1 Average Daily Waste Flow 750 # bedrooms X 2 people/br X 75 State Review Required? no Perc Rate 25 (T) Design Flow (Q) = # bedrooms X 2 people/bedroom X gpd X 1.75 Q= 1750 Absorption Area (A= Q/5 X SQRT) A = 1750 sq. ft. of absorption area required 97 infiltrator units without reduction or 583.3333 lineal feet of 3' wide trenches A maximum 30% reduction is allowed for use of deep gravel or gravelless chambered system. 1225 sq.ft. with reduction 68 infiltrator units with reduction 408.333333 LINEAL FEET of 3' wide trenches Type of system: OAbsorption trenches []Absorption bed O Gravelless chambers []Dry well OSeepage Pit OPumping Chamber Is an Engineer -Designed System required? no Minimum tank capacity SETBACK FROM WELL # of feet = 160 yes reason: 2187.5 gallons i1§111 Remember: 8 feet of additional distance for each 100 gallons/day of design flow over 1,000 gallons/day should be added unless an RPE can verify that it is not necessary to prevent contamination. APPROVED FOR ISSUE BY: SYSTEM INSTALLED BY: DATE OF FINAL INSPECTION REQUEST: FINAL INSPECTION BY: 3 Il Printed on Recycled Paper DATE: DATE: ASPEN/PITKIN ENVIRONMENTAL HEALTH DEPARTMENT ISOS DESIGN REQUIREMENTS DEPARTMENT USE ONLY Name Paul Samuelson House Siz 5 (75 gpd, 100 gpd, or 130 gpd) Number of Bedrooms, Lofts, Offices, Similar Rooms, Main House 3 Number of Bedrooms, Lofts, Offices, Similar Rooms, Caretaker unit 2 Average Daily Waste FlowyO # bedrooms X 2 people/br X 75 State Review Required? !l no Perc Rate 16 (T) Design Flo w (Q) = # bedrooms X 2 people/bedroom X gpd X 1.75 Q= 1750 Absorption Area (A= Q/5 X SART) A = 1400 sq. ft. of absorption area required 78 infiltrator units without reduction A maximum 30% reduction is allowed for use of deep gravel or gravelless chambered system. 980 sq.ft. with reduction 54 infiltrator units with reduction Type of system: OAbsorption trenches OAbsorption bed 0 Gravelless chambers ODry well OSeepage Pit OPumping Chamber Is an Engineer -Designed System required? no XX yes reason: Minimum tank capacity 2,000 gallons SETBACK FROM WELL # of feet = 160 Sr/` Cit! Permit # Z Parcel ID# Z.4!jf3-4$62- dt oos Will Remember: 8 feet of additional distance for each 100 gallons/day of design flow over 1,000 gallons/day should be added unless an RPE can verify that it is not necessary to prevent contamination. APPROVED FOR ISSUE BNDATE:� SYSTEM INSTALLED BY: DATE OF FINAL INSPECTION REQUEST: FINAL INSPECTION BY: DATE: Printed on Recycled Paper 3S- ASPEN/PITKIN ENVIRONMENTAL HEALTH DEPARTMO ISDS DESIGN REQUIREMENTS DEPARTMENT USE ONLY Name Paul Samuelson � Permit# '97,')12- Parcel 7D/ZParcel ID #Z - House Siz 6 (75 gpd, 100 gpd, or 130 gpd) 100 Number of Bedrooms, Lofts, Offices, Similar Rooms, Main House 4 Number of Bedrooms, Lofts, Offices, Similar Rooms, Caretaker unit 2 Average Daily Waste Flow 1 200 900 # bedrooms X 2 people/br X 75 State Review Required? no Perc Rate 16 (T) Design Flo w (Q) = # bedrooms X 2 people/bedroom X gpd X 1.75 Q= 2100 Absorption Area (A= Q/5 X SART) A = 1680 sq. ft. of absorption area required 93 infiltrator units without reduction A maximum 30% reduction is allowed for use of deep gravel or gravelless chambered system. 1176 sq.ft. with reduction 65 infiltrator units with reduction Type of system: OAbsorption trenches OAbsorption bed O Gravelless chambers ODry well OSeepage Pit OPumping Chamber Is an Engineer -Designed System required? no XX Minimum tank capacity SETBACK FROM WELL # of feet = 188 yes reason: -3111 gallons comw L5D:�p Remember: 8 feet of additional distance for each 100 gallons/day of design flow over 1,000 gallons/day should be added unless an RPE can verify that it is not necessary to prevent contamination. APPROVED FOR ISSUE DATE: e/4//� % SYSTEM INSTALLED BY: DATE OF FINAL INSPECTION REQUEST: FINAL INSPECTION BY: 2 Printed on Recycled Paper J� DATE: ASPEN/PITKIN ENVIRONMENTAL HEALTH DEPARTMENT ISDS DESIGN REQUIREMENTS DEPARTMENT USE ONLY Name Paul Samuelson Permit # 4Wl 2i Parcel I D # 21df3-t62- dt �vs House Siz 5 (75 gpd, 100 gpd, or 130 gpd) 100 Number of Bedrooms, Lofts, Offices, Similar Rooms, Main House 3 Number of Bedrooms, Lofts, Offices, Similar Rooms, Caretaker unit 2 Average Daily Waste Flovy0 # bedrooms X 2 people/br X 75 State Review Required? [[ no Perc Rate 16 (T) Design Flo w (Q) = # bedrooms X 2 people/bedroom X gpd X 1.75 Q= 1750 Absorption Area (A= Q/5 X SORT) A = 1400 sq. ft. of absorption area required 78 infiltrator units without reduction A maximum 30% reduction is allowed for use of deep gravel or gravelless chambered system. 980 sq.ft. with reduction 54 infiltrator units with reduction Type of system: DAbsorption trenches DAbsorption bed 0 Gravelless chambers ODry well OSeepage Pit OPumping Chamber Is an Engineer -Designed System required? no XX yes reason: Minimum tank capacity 2,000 gallons SETBACK FROM WELL # of feet = 160 Remember: 8 feet of additional distance for each 100 gallons/day of design flow over 1,000 gallons/day should be added unless an RPE can verify that it is not necessary to prevent contamination. APPROVED FOR ISSUE B DATE: SYSTEM INSTALLED BY: DATE OF FINAL INSPECTION REQUEST: FINAL INSPECTION BY: DATE: Printed on Recycled Paper 3� • l Nelson Environmental l; Wastewater Solutions Ltd W March 31, 1997 Gj/1 Gj 2- Mr. and Mrs. Paul Samuelson S 0040 Arbaney Lane Snowmass, Colorado 81654 Subject: Soils Evaluation and Percolation Test for Individual Sewage System Design for the Residence on Lot 5, Double X Quarter Circle Ranch Subdivision, numbered as 0040 Arbaney Lane Dear Gina and Paul, As requested, Nelson Environmental and Wastewater Solutions, Ltd., has performed a soils study and percolation testing to design a septic system for the residence at the subject site. We conducted this study according to Article 5 of the Pitkin Counter Readations on Individual Sewage Disposal Systems on Thursday, March 27, 1997. In addition we have attempted to conform to the Individual Sewage System Winter Soil Testing Policy (Policy 96-1) of the Aspen/Pitkin Environmental Health Department. We have based our recommendations on the subsurface conditions encountered at that time. We will furnish this letter and a copy of the enclosed data sheet to the Aspen/Pitkin Environmental Health Department to obtain a permit to construct this individual sewage system. Proposed Construction: The proposed two-story residence is to consist of two separate units. The main residence has . 2324 square feet of living area with three bedrooms and two and one-half bathrooms proposed. A 660 square foot caretaker apartment with two bedrooms and one bathroom is planned over the garage. Site Conditions: This site is in the Double X Quarter Circle Subdivision, overlooking the common pasture land fronting State Highway 82. Most of the lot is now pasture. The lot consists of a flat potion at the westerly property line, a relatively steep hillside sloping toward the meadow area, and a portion to the East of the power line that slopes at less than 5% toward the bottom of the lot. The ground surface, which appears natural in the proposed area of the absorption field, slopes to the Northeast at about a 10% grade. There is a small irrigation ditch overflow and culvert coming from the other common area pasture across the road to the West, about 25 feet from the closest percolation test hole locations. There is also a small stream along Watson Divide Road South of the southern property line. There is an existing drilled well recently completed on the property, reportedly 161 feet in depth. The lot is approximately 2.7 acres in size. �� P.O. Box 6961 Snowmass Village, CO 81615 Office (970) 923.3289 Home & Fax (970) 923.2766 0 0 Samuelson Duplex Residence Percolation Tests Lot 5, Double X Quarter Circle Subdivision March 31, 1997 Page 2 Subsurface Conditions: _ A soil profile pit to a depth of eight and three-fourths feet was excavated within 10 feet of the proposed absorption area. This excavation revealed that no groundwater or bedrock was observed to the depth of the profile pit. The soil consisted of a dark gray silty clay loam with small cobbles and rock fragments, two to eight inches in diameter, to the depth of profile excavation. The soil exhibited little tendency to swell when wetted or compacted under the pressure of the excavating equipment. The subsurface soil conditions were evaluated with the standard percolation test procedures at the approximate locations shown on Figure 1. The test holes were excavated by hand by the owner. Percolation Testing: Percolation testing was performed in the proposed absorption area North and Northeast of the residence. Normal winter procedures were used in preparing and presoaking the percolation test holes to determine the percolation rate for this area of the referenced property. The test holes were excavated by hand to a depth of 4 to 5 feet. At this depth, there was no evidence of frost, and the soil was relatively warm from the recent mild temperatures. The soil temperatures within the percolation test holes varied from 35° to 38° F. with the topsoil in the area of test hole #6 reaching 50° F. in the sunshine on the day of the percolation test measurements. Before and during the initial presoaking period the holes were covered with burlap sacks, a plastic tarp and a layer of 3/4" plywood. There was no snow cover on the proposed absorption area having melted in the two weeks prior to the percolation testing. We waited for weather conditions that were predicted to be above freezing during the day, before setting up the percolation test procedure. The weather on March 26 and 27 was clear and the afternoon temperatures were 50° F. The low was only about 20° F on March 26. Before the presoak was begun, the sidewalls were scrapped, all loose soil material removed, and gravel placed in the test hole to prevent scouring when water was added. There was no evidence of freezing or frost at the bottom of the test holes during these final preparation procedures. An initial filling of the percolation test holes was done by adding approximately 6 gallons of water to each of the holes the evening of the day before the percolation test was conducted. As soon as the water was added, the holes were again covered with insulation and plywood. As a check, water was left in plastic jugs overnight to check for freezing. None occurred. The percolation holes were then further pre-soaked by adding water to refill the test holes to a depth of fourteen inches several times for the nine hour period before beginning the percolation test. The ambient 139 0 0 Samuelson Duplex Residence Percolation Tests Lot 5, Double X Quarter Circle Subdivision March 31, 1997 Page 3 air temperature during the presoaking on March 27, 1997 was above freezing for most of the day, and no ice formed on the water in the test holes at any time during the presoaking period. The temperature at 5:00 p.m. was still 47° F. The test results obtained appear to be consistent with the soil type on the property and not significantly different from those rates obtained in earlier percolation tests or on adjacent lots. It is our opinion that if the test holes had frozen, the measured rates would have been much slower. This testing was performed in three shallow holes excavated with hand tools to a depth of c approximately inches. The results of the percolation testing are presented in Table I. These results indicate the silty clay loam soils have an average percolation rate of 16 minutes per inch, a satisfactory percolation rate under Pitkin County criteria. Limitations: This report has been prepared according to generally accepted practices in this area for use for sewage disposal design purposes. The conclusions and recommendations submitted in this report are based upon data obtained from our site visits at the location indicated. There is some possibility that the nature and extent of variations in the subsurface soil across the site may not have been evident at the time of this investigation, and may require additional evaluation if further excavation reveals conditions different from those described. This office should be advised of these situations as soon as possible so we may reevaluate our recommendations. If you have questions or if we may be of further assistance, please call the office. Sincerely, f �� Robert F. Nelson President Lam Reviewed By: 'V. tSchmeusei, ond, P.E. Gordon, Meyer Engineering i6 Nelson Environmental & Wastewater Solutions, Ltd E W TABLE I S PERCOLATION TEST RESULT FORM Hole Length Depth at Depth at Drop in Average Hole Depth of Interval Start of Interval End of Interval Water Level Percolation No. (in.) (Minutes) (Inches) (Inches) (Inches) Rate(Min./Inch) 4 50 12 59/16 43/4 13/16 10 43/4 41/4 1/2 (refill) 10 61/2 57/8 5/8 10 57/8 5 1/4 5/8 10 5 1/4 45/8 5/8 16 6 60 10 4 3 5/8 3/8 10 3 5/8 3 1/4 3/8 (refill) 10 8 75/8 3/8 10 75/8 7 1/8 1/2 10 71/8 65/8 1/2 20 7 48 1/2 10 43/4 4 3/4 10 4 33/8 5/8 (refill) 10 57/8 5 7/8 10 5 43/8 5/8 10 43/8 3 5/8 3/4 11 Gina and Paul Samuelson Property 0040 Arbany Lane Lot 5, Double X Quarter Circle Ranch Date of Percolation Test: 03/27/97 Iq / P.O. Boz 6961 Snowmass Village, CO 81615 Office (970) 923.3289 Home & Fax (970) 923.2766 0 Nelson Environmental & Wastewater Solutions, Ltd 0 E Property Address: 0020 Arbanev Lane W S Legal Description: Lot 5, Double X Quarter Circle Subdivision Property Owner Name Paul and Gina Samuelson Address 0040 Arbanev Lane Snowmass, CO 81654 Phone: 923-4538 Contractor: Name: Dan Gruenefeldt Address: P. O. Box 1910 Basalt, CO 81621 Phone: 963-4979 Saturation and Swelling o Smeared surfaces removed X Yes o Gravel Added X Yes To a 4" Depth o Date and Time presoak water added 03/26/97 (d), 4:05 am. o Amount of presoak water added 6 gallons/test hole on 3/26/97 24 gallons/test hole on 3/27/97 o Water remaining in holes after overnight presoak? Hole 4: _Yes X No Hole 6: Yes X No Hole 7: Yes X No Percolation Rate Measurement Hole 4: 16 minutes/inch Hole 6: 20 minutes/inch Hole 7: 11 minutes/inch AVERAGE 16 minutes/inch Excavating Contractor: Name: Stutsman-Gerbaz.lnc. Address: 0755 Gerbazedale Dr. Snowmass, CO 81654 Phone: 923-2734 Groundwater: o Not Encountered to 8 3/4 ft. o Estimated depth to high seasonal water if not encountered- 100 feet o Is area believed to be subject to seasonal fluctuations which could result in a seasonal water table? _ Yes X No Slope in absorption area 10% to the Northeast Bedrock o Not Encountered o Estimated depth if not encountered -180 feet o Type of bedrock: Sandstone X Claystone or Shale Siltstone Other: o Is bedrock believed to be permeable? Yes X No I certify that the above information is correct and complete to the best of my knowledge and that all tests were performed in accordance with the provisions of Pitkin County Individual Sewage Disposal System Regulation, Articles 5.1 through 5.8 and under the supervision of a Registered Professional Engineer. Robert F. Nelson President Reviewed by: ASGMammond,P.E. nc., Engineers P.O. Box 6961 Snowmass Village, CO 81615 Office (970) 923.3289 Home & Fax (970) 923.2766 Y%NoCLL: L3 20 5 LA9) REERAR 4 0 ul �6EKBAz W,�cL, fi 300 � GEegnz Scrno, I Svsrcw I 1 I 1 1\ 1 I \ I II I J II � I11 II I I 11 I11 / II V r`. v I I I I I I \ I \ I \ \ 9 0 1 s DINQ ENVE OPE\— 1 1 \ Proposed House Location 99 \IA / \ WELL \\ \\ \I\ 1 North 5 Approximate Scale: V-40, OXA Irl"IrWw Samuelson Property Lot 5, Double X Quarter Circle Subdivision FROM 1 1 STUTSMRN GERBRZ r FAX NO. : 970 923 0647 1- I 4 V � yS^ Q `I -/,i AMay. 09 2000 07:41AM P1 J & M PUMP COMPANY 0241 COUNTY ROAD 167 GL NWOOD SPRINGS, CO 61601 (303) 9456159 March 13,1997 Paul & Gina Samuelson 0040 Arbaney Lane Snowmass Co. 81654 RE: Well Test Attn: Paul, A two hour well test was performed by J & M Pump Co. on property located at 0040 Arbaney Lane. The following results were obtained: Well: 161' Water Level: 77' Drawdown: 2' Sustained Yeild: 15 GPM Water Clarity: Cloudy A bacteria sample was drawn at the end Snowmass Water for analysis. Results will be have any questions, please feel free to call J & M Pump Co. Aa Richard A Holub Lic. No. 1196 LIS of the test and taken up to sent to my office. If you 945-6159. Thank You. Form No.' OFFICE OF THE STA ENGINEER GWS -25• COLORADO DMSIOIWF WATER RESOURCES 46 618 Centennial Bldg., 1313 Sherman St, Denver, Colorado 80203 _ L303� 866-3581 APPLICANT GINA & PAUL SAMUELSON 0040 ARBANEY LN SNOWMASS CO 81654- (970)923-8911 PERMIT TO CONSTRUCT A WELL WELL PERMIT NUMBER 047946 - DIV. 5 CNTY. 49 WD 38 DES. BASIN MD Lot: 5 Block: Filing: Subdiv: DOUBLE X QUARTER CIH(:LE 1095 APPROVED WELL LOCATION PITKIN COUNTY SW 1/4 NW 1/4 Section 6 Twp 9 S RANGE 85 W 6th P.M. DISTANCES FROM SECTION LINES 2280 Ft. from North Section Line 1170 Ft. from West Section Line ISSUANCE OF THIS PERMIT DOES NOT CONFER A WATER RIGHT CONDITIONS OF APPROVAL 1) This well shall be used in such a way as to cause no material injury to existing water rights. The issuance of the permit does not assure the applicant that no injury will occur to another vested water right or preclude another owner of a vested water right from seeking relief in a civil court action. 2) The construction of this well shall be in compliance with the Water Well Construction Rules 2 CCR 402-2, unless approval of a variance has been granted by the State Board of Examiners of Water Well Construction and Pump Installation Contractors in accordance with Rule 18. 3) Approved pursuant to CRS 37-90-137(2) on the condition that the well be operated in accordance with the Aspen Village Inc. Augmentation Plan approved by the Division 5 Water Court in case no. 81CW432 for CXQC Well #5. If the well is not operated in accordance with the terms of said decree, it will be subject to administration including orders to cease diverting water. 4) Approved as the only well on a residential site of 3 acres described as lot 5, Double X Quarter Circle Subdivision, Pitkin County. 5) The use of ground water from this well is limited to domestic purposes on one residential lot and the irrigation of not more than i acre of lawns and gardens as decreed in case no. 81CW432. 6) The maximum pumping rate shall not exceed 15 GPM. 7) The annual amount of ground water to be withdrawn shall not exceed 3.0 acre-feet. 8) The return flow from the use of the well must be through an individual waste water disposal system of the non- evaporative type where the water is returned to the same stream system in which the well is located. 9) A totalizing flow meter must be installed on this well and maintained in good working order. Permanent records of all diversions must be maintained by the well owner (recorded at least annually) and submitted to the Division Engineer upon request. 10) This well shall be constructed not more than 200 feet from the location specified on this permit. 11) The owner shall mark the well in a conspicuous place with well permit number(s), name of the aquifer, and court case number(s) as appropriate. The owner shall take necessary means and precautions to preserve these markings. r, y. i APPROVED44.1 Z ,State !� Receipt No. 0410519 EngineerDATEISSUED MAR 0 1997 EXPIRATION DATE MAR 0 6 1998 IWill 0 0 Shelton Drilling Corp. P.O. Box 1059 Basalt, Colo. 81621 (970) 927-4182 Lic. # 1095 Invoice # C-1032 Name Gina & Paul Samuelson Date 03/13/97 Go : Casing ID Address Permit # : 047946-F 0040 Arbanev Lane City, St, Zip Location Watson Divide Snowmass, Co. 81654 Phone # : (970) 923-8911 Hole Size Depth Type Casing ID Casing OD From -To 9.0 85 Steel 6.5 7.0 0-85 6.5 160 Steel 5.0 5.0 73-160 Perforated Ft 40 ft Estimated 15 gprn Static Level 75 ft Total Drilled 160 ft Recommended Pump Set Depth 155 Ft. Pumping 15 GPM. For Pump Installation We Recommend : Aqua Tec Pump 984-0311 (Tom Platzer) Samuelson Pump 945-6309 (Raun Samuelson) J & M Pump Cc 945-6159 (Rick Holub) Special Instructions : Price Per Foot 5 Feet @ $ 30.00 Per Foot = $ 1,950.00 Feet @ $ � Per Foot = $ 2,125.00 Total Invoice. . . . . . . . $ 4.075.00 Conditions Of Payment : pay $ 4.075.00 PLEASE READ THE FOLLOWING RECOMMENDATIONS 1.. WE STRONGLY RECOMMEND A VALID PUMP TEST BE CONDUCTED BY A LICENSED PUMP INSTALLER TO DETERMINE THE ACTUAL WELL PRODUCTION AND WATER QUALITY. THIS SHOULD ESTABLISH THE ACTUAL WELL PRODUCTION PARAMETERS WHICH WE CANNOT DETERMINE WHILE DRILLING. 2. On Monitoring/Observation Holes (test holes) it is the customer's responsibility to obtain the proper permit before the well is put to beneficial use (within one year) or the State may require the hole be plugged and abandoned. We will be happy to assist you whenever possible in filling out the appropriate well application. 3. The landowner is ultimately responsible for the plugging and abandoning of dry holes or replaced wells, according to State Rules and Regulations. Please contact us for details and/or prices. BILLING. Please call us if you have any questions . 9� THANK YOU 161 FORM N0. GWS -32 10164 PUMP INSTAlifigN AND TEST REPORT STATE OF COLORADO, OFFICE OF THE STATE ENGINEER For Office Use only 1. WELL PERMIT NUMBER 047946 F 2. OWNER NAME(S) Gina & Paul Samuel on Mailing Address 0040 Arhanay Tana City, St. Zip Rnnwmacc rn 81 654 Phone ( 970) 923-8911 3 WELL LOCATION AS DRILLED: SW 1/4 NW 1/4, Sec. 6 Twp. 9 S Range 85 W 6th DISTANCES FROM SEC. LINES: 2280 ft. fromNo�Sec. line. and 1170 ft. from Ws Sec. line. SUBDIVISION: LOT_ BLOCK FILING(UNIT) STREET ADDRESS AT WELL LOCATION: PUMP DATA: Type Submersible Installation Completed 3/13/97 Pump Manufacturer rnu1 d -g Pump Model No. 1 or-gl nd, 2T 4. Design GPM 1 0 at RPM -j4Sn __ HP 1 , Volts 2 -in Full Load Amps 8 6 Pump Intake Depth 1 55 , Feet, Drop/Cure:,., ripe Size 1 i ll Inches, Kind Sch 80 PVC ADDITIONAL INFORMATION FOR PUMPS GREATER THAT 50 GPM: TURBINE DRIVER TYPE: ❑ Electric ❑ Engine ❑ Other Design Head feet, Number of Stages Shaft size inches. 5. OTHER EQUIPMENT: Airline Installed ❑ Yes ❑ No, Orifice Depth ft. Monitor Tube Installed ❑ Yes ❑ No, Depth ft. Flow Meter Mfg. Schlumberger Meter Serial No. 39301 976 Meter Readout ® Gallons, ❑ Thousand Gallons, ❑ Acre feet, ❑ Beginning Reading 0 6. TEST DATA: ❑ Check box if Test data is submitted on Supplemental Form. Date 3/13/97 Total Well Depth 161' Time 2 14R Static Level 77, Rate (GPM) is Date Measured Pumping Lvl. _____2_9_r 7. DISINFECTION: Type Chlorox Amt. Used 1 cup Liquid 8 Water Quality analysis available. ❑ Yes ❑ No 9. Remarks 0. 1 have read the statements made herein and know the contents thereof, and that they are true to my knowledge. [Pursuant to Section 24-4-104 (13)(a) C.R.S., the making of false statements herein constitutes perjury in the secon degree and is punishable as a class 1 misdemeanor.] CONTRACTOR J & M Pump Cn Phone (970) 945-6159 Lic. No. 11 96 . Mailing Address 0241 Co Rd 167 Glen SPgs CQ. 81 601 Nama/ a/(Please type or print)Signat // - Date L/31 STANDARD BACTERIOLOGICAL WATER TEST Colorado Department of Public Health and Environment AFFIX FEE x270 East t ith Avenue • Denver. Colorado 80220 PREPAID L.AB SEE BACK OF THIS COPY �!��� T�� �� �J'• / C STAMP HERE FOR EXPLANATION OF (II Applicable) TESTS PHONE ® t SAMPLE NAME Of RAW o �.����•� -Lx.EV TIME SUPPLv 1LCL].At.[Ll�. iIN15NFw _Lt❑ TEST RESULTS ARE > w CHLORINE n�ws•NnE MEMBRANE FILTER w z SAMPLER �( 1(_� RESIDUAL MGIL ADJUSTED w O / COUNT O COLIf0E1M/10a MI U ,PwprE A h L 1 MOST PROBABLE NUMBER �(J/gJpRESE wnIFRE yuhF WA4 MEN. PLEASE INCLVDE CITYI N -.^MMUNITv $IJy�IET ❑NONCOMMUNITY ROUTINE MPN _ _ _— COLIFORMi100 ML ❑SPECIAL PURPOSE SAMPLE ~ ` vnc p�CpMPLR ino 4(lVT4 �c _ LAeORATGRv ANALYST J ly -�T m o DDURANGO ❑ DENVER `KESS ( i I `[ ( l0- ❑ GRAND JUNCTION leu c� 1 v c�LL•u STATE ZIP—•O ff/r e5 0� is N -TE IF ALL INFORMAT N NOT SUPPLIED THE SAMPLE WILL BE DISCARDED '^��'B�p%yG K' REVERSE FOR TIME LIMITATIONS SAMPLING INSTRUCTIONS AND DEFINITIONS �oyd� r p p I NTRO I06 IPev 4/PAI TB DIRECT D ae MEMBRANE FILTER 9B A I vERIFIEO 14 I