Permit #: 10015
Permit Issued:
Owner(s): Roclm
WASTEWATER TREA*ENT SYSTEM (OWTS)
CONSTRUCTION PERMIT
0405 Castle Creek Road, Suite 10 • Aspen, CO • 81611
Phone: 970.920.5070 Fax: 970.920.5077
Parcel ID #:
2467-344-00-001
[]NEW ®REPAIR ❑REMODEL/ADDITION ❑TANKONLY ❑FIELDONLY []AMENDMENT
Mountain Institute
Property Address: 30 Shining Mountain
Legal Description:
Size of Lot: 7 acres Acres
Size of Building:
Sq. Ft.
Detached Accessory Unit:
Size of Accessory Unit:
The system is designed for: 4 bedrooms (Duplex)
DYES ®NO
Sq. Ft
Designed By: All Service Septic Project #: 1718 Dated: May 28, 2010
Phone #: 970-618-5033 Mailing Address: PO Box 2844, Glenwood Springs, CO 81602
Fax #: 303-216-2796
Email Address: Toetzl0comcast.net
Perc Rate: 27 mpi Profile Hole Depth: 8 ft Depth to Groundwater or Bedrock: Greater than 8 ft
Minimum Tank Capacity: 1125 gallons Minimum Absorption Area: 655 sq ft w/ 50% reduction
Permit Conditions:
This OWTS Construction Permit is approved on the condition of compliance with the engineer design as submitted with the application and the specifications
cited above. Changes must be approved by this Department and the engineer prior to construction.
This system will continue to use the existing 1250 gallon tank. An additional 500 gallon pump tank must be
installed. The pump will distribute effluent to an automatic distributing valve and then to four gravelless chamber
trenches all with 1.5" suspended laterals. The first trench on the uphill side on the south side of the tank will have
10 chambers, the trench below that will have 14 chambers, the trench on the uphill side o e north side of the
tank will have 22 chambers and the trench below that will have 21 chambers for a total o(67,lchambers. There
must be at least 6' of undisturbed soil between each trench. The ADV must be placed at a igh point to assure no
water remains in the lines after each dose.
No component of the system may come within 10 feet of the property line (specifically, the south property line).
The system was designed as high up the hill as possible to create some separation from the steep bank below (25'
on the south side of the tank and 20' on the north side of the tank).
This Permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an "as -built" letter to this
Department within 30 days of the final inspection, unless a longer period of time has been agreed upon, in writing. This Department must also be called for
the final inspection with a minimum of 48 hours notice.
Minimum horizontal distances between components of the system and physical features shall conform to the requirements of the Pitkin County OWTS
Regulation.
This Permit is conditioned upon the property owner(s) providing for regular inspection, cleaning, and maintenance of the system by qualified personnel, in
accordance with the manufacturer's recommendations and the requirements of the Pitkin County OWTS Regulation.
THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN
COUNTY OWTS REGULATION, INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE.
Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby
given to the property owner(s) to perform the work indicated in accordance with the Pitkin County OWTS Regulation. This
Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built" drawing
must be submitted and approved -by EH/NR before final approval of the system will be issued.
Issued By: _62A_(.0 �sti� Date: 2 10 Expires: 9/
Installer: License M
Leava0
Reactivation Authorized by:
Final Approval Issued By: Date:
New Expiration Date. ElraPod
IC as
MHINRNSITE WASTEWATER TREA - NT SYSTEM (OWTS)
CONSTRUCTION PERMIT
0405 Castle Creek Road, Suite 10 Aspen, CO 81611
Phone: 970.920.5070 Fax: 970.920.5077
Permit #: 10015 Parcel ID #: 2467-344-00-001
Permit Issued: []NEW ®REPAIR ❑REMODEL/ADDITION [:]TANKONLY ❑FIELD ONLY ❑AMENDMENT
Owner(s): Rocky Mountain Institute
Property Address: 30 Shining Mountain Way
Legal Description:
Size of Lot: 7 acres Acres Detached Accessory Unit: ❑YES ®NO
Size of Building: Sq. Ft. Size of Accessory Unit: Sq. Ft.
Designed By
Phone #:
Fax #:
Perc Rate:
Minimum Tank Capacity
Emergency Repair for Duplex (4 bedrooms)
Project #:
Dated
Mailing AddresL
Email Addtiis
Profile Hole Depths /��i Depth to Groundwater or Bedrock:
I Mi1Vo Absorption Area:
Pert' itConditions:t E
This OWTS Construction Permit is approved on th�condition of corilliliance with the *§i hesign as submitted with the application and the specifications
cited above. Changes must be approv�l�y�his Department and the engineer prior t0 struction.
Emergency use of this system may continue under the following conditions...
1. The existing 1250 gallon tank must be pumped to start from a minimal liquid level.
2. The outlet(s) on the tank must be plugged, not allowing any effluent to exit the tank.
3. Residents of the duplex shall be instructed to use water conserving practices. It is recommended that there
be no use of washing machines and showers and dishwashing kept to a minimum.
4. When the volume of effluent in the tank approaches capacity, it must be pumped by a Licensed Systems
Cleaner.
A completed CWTS Construction Application and accompanying paperwork should be submitted to this
department no later than June 25, 2010. Actual repairs should be completed no later than July 26, 2010.
Please notify this department if these deadlines will not be feasible. If extended deadlines are necessary,
emergency use of the system may be reassessed.
This Permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an "as -built" letter to this
Department within 30 days of the final inspection, unless a longer period of time has been agreed upon, in writing. This Department must also be called for
the final inspection with a minimum of 48 hours notice.
Minimum horizontal distances between components of the system and physical features shall conform to the requirements of the Pitkin County OWTS
Regulation.
This Permit is conditioned upon the property owner(s) providing for regular inspection, cleaning, and maintenance of the system by qualified personnel, in
accordance with the manufacturer's recommendations and the requirements of the Pitkin County OWTS Regulation.
THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN
COUNTY OWTS REGULATION, INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE.
Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby
given to the property owner(s) to perform the work indicated in accordance with the Pitkin County OWTS Regulation. This
Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built" drawing
must be submitted and approved by EH/NR before final approval of the system will be issued.
Issued By: (�(�� .���. Date: 5/ U Expires:
Installer: License #:
Reactivabort Authorized by:
Final Approval Issued By: Date: I New Expiration Date: Elfieepy
MAY.20. X1,) '2:5EFM EAD h[ALTH NAT RESOURCE 0 No. 191; ?.
ONSITE WASTEWATER TREATMENT SYSTEM (OWTS)
CONSTRUCTION PERMIT APPLICATION
ca rtA 0405 Castle Creek Road, Suite 10 • Aspen, CO 81611
Phone: 970.920,5070 Fox: 970.920.6077
Parcel 100 levelabte from the Pitkin County Assessors Offin
970.9205160 or at sMMwajLfisLj1jj2r":
vce
-
Purpoce of Pamir. ❑ NEW REPAIR WE TO FAILURE
Erq eAk
❑ REMODLNADDnION
❑TANK ONLY FIELD ONLY
coat of Repi RemodWAddioon(spprouvnste):
eve
Bualneaa Phots:
0- o
Iy 1
3 sAivJin/� o Nti'lAin
SNou//Yl SS
C�17 8
Lot; ROM: Filing: Gubdvuim:
ire SY S72 35f T$ Si' le6 uv
5
Lot Sac (in a ): r1 A 1Lr'e
J4 jW
Size o Budtfing (square`eet):
Omers Malvig Address
.-317 SA/oJrna.TS
'ry. Smte. Lp:
S3em gle'si/
Home Phone:
oKa as —
3a d
-Coruasr btfonnexdn must se pmwOW rortne curlersgn:ng ova AppllmW.
Primary CAl P AppUCam (i not
vce
rAm S tI!G
comacUAp icant Mailing Addr s:
Agme )Fs boue__
City, Siete, p:
Cell Ph"
`l7a 48-
Bualneaa Phots:
0- o
Fax Number.
D-987-3
it Addle a:
o s oa c CLE &5.0R
Buildmp PaartNX(M applicable)
Lot Sac (in a ): r1 A 1Lr'e
Size o Budtfing (square`eet):
Numtw • Bedrooms:
Urih ❑ YES
No
Size of Att"Ory Um (equate reet):
Number of Potential Botlmoms In a Fixture U3T for the Aooe6aery Unit
Weser &ou=
❑ PRNAIE WELL
❑ 5t1RPACE WATER
❑SPRING ACOMMUNI7YJPU&IC WAT9l5YSrBt
Nama of C4nmijAty1Fuoric water bystorn (d apptrrebN):
e tnl+at
�/�J rs n.
PLEASE READ BEFORE SIGNING:
I Certlty that ft above Intonmaeon is complete and eaurate brd that 1 naw provided Complete and accw" Information In all of the documorde
included in my application package. I aumowledge that EWNR may mole any permit I Am Issued I my appliuWon N found to contain any
InScCu", fal%a, or misleading information. i under stand thet no combustion may G undenakm on an OWrS ural an OWTS Construction Portrait
is iaeuad.
i
_ ti t.,
an: nitvi-m n� iw
ID#:
94� Pitkin County Environmental Health Department
Contact Log Sheet
I
tobeT
July 11, 2010
Li
PO Boz 2844
Glenwood Springs, CO 81602
Ph 970-618-5033
Fax 303.216-2796
RMI
At: Richlyn Pavicek
2317 Snowmass Creek Road
Snowmass, CO 81654
Installation Observations for OWTS
0029 Shinning Mountain Way, Permit 410015
Pitkin County, Colorado
Richlyn,
r
Project No. 1718
ALL SERVICE septic, LLC performed installation observations for the onsite wastewater treatment
system (OWTS) on June 15th and June 30th 2010 for the subject property.
The installation included the,existing 1250 -gallon septic tank, followed by a 500 -gallon concrete
peptic tank with a pump]The drain field consisted of 4 gravelless chamber pressurized trenches, with
each trench having between 8 and 18 ARC -36 chambers. The total new infiltrative area is 680 SF.An
automatic distribution valve (6404) will serve and pressurize the chamber trenches.
The OWTS was generally installed according to specifications. This observation is not a guarantee of
workmanship and/or parts and materials. ALL SERVICE septic, LLC should be notified if changes
are made to the OWTS.
LIMITS:
The observation was based on information submitted and our site visit. If conditions are different
from conditions described in this letter, ALL SERVICE septic, LLC should be notified. All additional
OWTS construction must be according to the county regulations. The installer should have
documented and demonstrated knowledge of the requirements and regulations of the county in which
they are working.
Sincerely,
ALL SERVICE septic, LLC
Timothy R. Petz
2 copies sent
Copy sent to Pitkin County Health Dept.
WE
Reviewed
A
Richard H
\
cn
ƒwo
r �(�
§� Z� `>}
�k
k§ (j
n
----------------
�z
k§
!z z
§ �
� &k
.A » CHAMBERS 0
amC-3,__...
�I
18 ARC a CHAMBERS
,ARC 36 CHAMBERS z
02k
cut
�Q c _K
. /§ §§ 3o& G ;(M)(
§i // ``( ) \o\!o
+
7§ Rz §( ) §77)§
j 28 ?w q §03 \ƒ]§
I $0 8m:�0
!6!§i
\�
I �-1m
{�$;(2
rmn
I ;®
}f � .
0
q?-T3g2O
0
Gxrla.05+6eq�&, Wq,i�An .
C -0 -Us
P Apt VQU 4 &L c "AA c c tier fisc
6- 6 'QiA %,-A
CBv�.&-p v� fw� ► P C �D �W- t4k� iso
vi 48�
rnC�) uv � `far \L i o GJ via �o�ir S
�-1�.,-►� cam- `� �'�` ��J �- �`-�c � ,�.�l�►-ee- `��...
V
I\;Y:
1 "1
Aou
Aousc
mass
ME
0 Q fIV
o
d t2I)( 10 J
7 V -9--e - 1
7 -- I 4--A-24
V", W 5
or 5x ly
OWTS DESIGN CALCULATIONS - for Pitkin
Owner's Name Parcel ID #
House Size (sq. ft.) (75 gpd or 100 gpd)
75
Number of Bedrooms in Main House
Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House
Number of Bedrooms in Detached Caretaker unit
Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit
(If the caretaker unit is ATTACHED, treat as if part of main house.)
Average Daily Waste Flow 600
State Review Required? no
Perc Rate M
Design Flow (Q) = # potential bedrooms X 2 people/bedroom X gpd X 1.5
Q- 900
Minimum tank capacity 1125 gallons
Absorption Area (=Q/5 X SQRT perc rate)(1.4 loading factor)
A = 1,309 sq. H. of absorption area requued
Absorption Area (=Q/5 X SQRT Perc rate) WITH SECONDARY TREATMENT (no loading factor)
A= 935 sq. ft. of absorption area required
Abs. Area w/ loading factor (B25) Trench Bed
Quick4 Trench
Quick4 Bed
Pipe and Gravel (-10%) 1173 no red.
1309
119
133
Dosing (-20%) 1048 (-20%)
1048
106
106
Chambers 1-'A%) 917 (-10%)
1178
(-�p
119
Max Allowable Lm°i) ku (-30%)
n7
66
3�
( 9
Secondary Treatment
`1n
Abs Area w/ out loading factor (B28) Trench Bed
Pipe and Gravel (-10%) 842 no rem.
935
85
95
Dosing (-20%) 748 (-20^x)
748
76
76
Chambers (-30%) 65.5 (-10%)
842
66
85
Max Allowable (-50%) 469 (ao^,)
655
47
66
100
SETBACK FROM WELL
# of feet =
50
SETBACK FROM POND, STREAM OR IRRIGATION DITCH
# of feet =
25
SETBACK FROM DRY GULCH
# of feet -
May 28, 2010
PO Box 2844
Glenwood Springs, CO 81602
Ph 970-618-5033
Fax 303-216-2796
John Roberts and Richlyn Pavicek
0029 Shinning Mountain Way
Snowmass, CO 81654
Project No. 1718
Subsurface Investigation and Repair Onsite Wastewater Treatment System Design, Existing Duplex
Units
0029 Shinning Mountain Way
Pitkin County, Colorado
Don,
ALL SERVICE septic, LLC performed a subsurface investigation and a repair onsite wastewater
treatment system (OWTS) design for the subject residence. The property is located outside of Woody
Creek, in an area where OWTS and wells are necessary.
SITE CONDITIONS
Two duplex units, for a total of 4 bedrooms, exist on the subject property. The units utilize an OWTS
which is experiencing problems. The existing 1250 -gallon, septic tank is in good condition and may
be incorporated into the repair. The existing drain field must be abandoned. The proposed drain field
area slopes 15% to the east, and vegetation consists of a moderate cover of grasses. Water is provided
by the local water district. There are two wells located greater than 200 feet to the north serving
neighboring properties.
SUBSURFACE
The subsurface was investigated by digging one profile pit and three percolation holes, as indicated. The
materials encountered in the profile pit consisted of 1 -foot of a clayey root zone, underlain by sandy clay
to the maximum depth explored of 8 feet. Groundwater or bedrock was not encountered. Three
percolation holes were dug, in the area of the proposed drain field, as indicated. Percolation rates
ranged from 20 to 40 minutes per inch (MPI). A 27 MPI rate will be used to design the OWTS.
DESIGN SPECIFICATIONS
The OWTS design is based on 4 -bedrooms and an average sewage load of 600 GPD. The installation
must include the existing 1250 two-compartment septic tank, followed by a 500 -gallon concrete
pump tank. Four gravelless chamber trenches, using `Quick4' Infiltratorrm chambers, must be
installed as indicated. Each trench must have 1 row of chambers as indicated on plans, with a 1.5-
0
inch suspended lateral, for a total of 671 square feet
distributing valve (6404) must be used to distribute effluent.
SubsIlce Investigation and OWTS De3ign
Project No. 1718
6/02/10
Page 2
(SF) of infiltrative area. An automatic
Construction must be according to the Pitkin County Environmental Health and Natural Resources
Department OWTS regulations, the OWTS Construction Permit provided by Pitkin County
Environmental Health and Natural Resources Department, and this design.
OPERATION INFORMATION AND MAINTENANCE
The surface of the drain field should be seeded upon completion. Vegetation is an important factor in
drain field performance. Erosion control should be practiced prior to and during re -vegetation. Geo -
fabrics or plastics should not be used over the drain field. No heavy equipment, machinery, or
materials should be placed on backfilled drain field. Livestock should not graze on the drain field.
Plumbing fixtures should be checked to ensure that no additional water is being discharged to OWTS.
For Example, a running toilet or leaky faucet can discharge hundreds of gallons of water a day and
harm a drain field.
The homeowner should pump the septic tank every two years and clean the effluent filter as needed.
Garbage disposal use should be minimized, and non -biodegradable materials should not be placed
into the OWTS. Grease should not be placed in household drains. Loading from a water softener
should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS.
Mechanical room drains should not discharge into the OWS. The OWTS is engineered for domestic
waste only.
ADDITIONAL CONSTRUCTION NOTES
If design includes a pump, air release valves and weep holes should be installed to allow pump lines
to drain to minimize risk of freezing. Excavation equipment must not drive in excavation of drain
field due to the potential to compact soil. Extensions should be placed on all septic tank components
to allow access to them from existing grade. Precast concrete tanks and distribution boxes should be
used, unless plastic or fiberglass is required. Access to all tank compartments and distribution devices
is optimal.
INSTALLATION OBSERVATIONS
ALL SERVICE septic, LLC, and the county must view the OWTS during construction. The OWTS
observation should be performed before backfill, after placement of chambers and distribution pipes.
Septic tanks, distribution devices, pumps, dosing siphons, and other plumbing, as applicable, must
also be observed. ALL SERVICE septic, LLC should be notified 48 hours in advance to observe the
installation.
�a
•
Subsurface Investigation and OWTS Design
Project No. 1718
6/02/10
Page 3
LIMITS:
The design is based on information submitted. If soil conditions encountered are different from
conditions described in report, ALL SERVICE septic, LLC should be notified. All OWS construction
must be according to the county regulations. Requirements not specified in this report must follow
county regulations. The installer should have documented and demonstrated knowledge of the
requirements and regulations of the county in which they are working.
Please call with questions.
Sincerely,
ALL SERVICE septic, LLC
Timothy R. Petz
3 copies
i3
Reviewed
�l
Richard H
/\
�
\
#j;;�
!!!§ i §/\\}(
C }
§" m !
0_O§
9
Ip!!;E
t m
■°|§§
Mx
;
K(`
q
,!
R
R
\\�
--
/—
/
2
\;
801
m-2
;
•
z
;,
\j
§\
(\
j
�;
�z
M M
=o
|�Z
!/
\
|(M
§§
§\
)!
§
|!
,k
f (
k2,2,Q-
®
0
�
\
#j;;�
!!!§ i §/\\}(
C }
§" m !
0_O§
9
Ip!!;E
t m
■°|§§
Mx
;
K(`
q
,!
R
R
\\�
--
/—
/
2
\;
801
m-2
;
z
\(�
\j
§\
(\
j
�;
�z
M M
=o
!/
|(M
|!
,k
f (
�
\
#j;;�
!!!§ i §/\\}(
C }
§" m !
0_O§
9
Ip!!;E
t m
■°|§§
Mx
;
K(`
q
,!
R
R
\\�
>
KOFDROCNS-BOOCPD
LOADING • .-800 x 13-YW GPD
PERCOLAT CA RATE -1.2] MINUTES MR NCH Wi
CALCULATED AREA -(115%y X Man 1)151 F to -1209 SF
PROPOS ED AREA- 1309 SF x 5016 REDUCTION -M&F
WDTN OF TRENCHES • 3FEET -1 CHAASIER
LENGTH OF ❑UCRA' TRENCHES -.O T0S9 FEET
TOTAL NUA6E R OF' W ICKd' CNA/.6FA4 -10 TO 22 CNRLBEAS
TOTAL N Ftl.TRATNE ARFA • 8T18F
F.R 1GTAL TRENCNEB
SWEEP 12 WAY CLEANOUT OETAILS IMT.SI TYPKAL DRAIN HEW CROSS BECTON -WP. INFILTRAT0RM) GUICKWtMl CUT 9XFET 095ERVARON AUTOMATIC DISTRIBUTING VALVE OUML
vM MODEL 0,404
1,00
PJC CAP
FNMFLUE .'PVCOSERVATINPPE 3ODIAMETERPC
LMIT OF SS RLRER IWS FEDIEXCAVATIONT1rSEWER I 1SLWE-aSCHEDE COPPER OSMP% TUN T MIN MWAU—TC
1 OO P.V.0i1NCERWIREMAY RE FROMEFFLUENT WSTALLED TO 1S >t-
LOCATELNEN SUSPENDED G11CKf 14 PUFAPPlO SYSTEM 1.2S WLETrWD
FIIDIpE GMVELLE55 SCARIFY SURFACE PVC"P TO ENTERN pURETS
1.SNCHIATEpAL CHAMBER PRIOR TO PLACEMENT TOP PORT
WNH NYLON MP IA.F3.1 OFSAMO OF END% TE
TIES
SODGALLON CONCRETE
PUMP CHAR@ER
PIAN WEW -TYP.
O.V WC PUMP LINE
FROM TANK
IN ALL CHAMBER TRENCHES OBSERVATION WE
1.5 -INCH SUSPENDED LATERALS G TESS CHAMBER END PLATE TYP.
WITH 1/4 -INCH HOLES ON 2 FOOT 'OUICKJ'
CENTERS FACING UP. ONE HOLE AUTOMATE:
FACING DOWN FOR DRAINAGE N00 YALYE� FILAR
WE TO ENTER
CHAMBER IN TCP PORT
OF END PUTE
2 TRENCH DETAILS
u
fff111
I I
RMI
p P.O.Box 2844
OIL
L C+Ianwo Sgin5s. CoaaED 81802
0029 Shinning MDumeln WayPluone
W2.0
RFny 7
PIIMn county, CO
Fax W3.70.81N.5033
Fax 303.21fi.2796
1718
ProjeCl NYmDx. 1]19
Shoal 2 Of 3
500 -Gallon, PLASTIC or CONCRETE Effluent Pumping Tank
ONE MANHOLE, RISER, AND UD FOR
SEPTIC TANK ACCESS IS ACCEPTABLE
PUMP MUST BE CAPABLE OF:
1. 26.7 GALS PER MINUTE
2. 20.9 FEET OF TOTAL DYNAMIC HEAD
ELECTRICS:
1. A DEDICATED CIRCUIT SHOULD BE USED
FOR PUMP AND ALARM/PANEL
Inlet Two
11
L LGlen
Bwood Springs. Colorado 8`1602SfRYICf
with Cord Grips
4
303.20fi27%33
Fax
3 TANDETAIL arra
Tank Adapter (cost or bofted)
Loved Control
Flag Assembly
Check Valva (optimed)
Pump
Port
— Placed on Concrete Block
PJC Stake Box
with Cord Grips
TE
ND LID
Fiberglass Gaskeled Lid with
Stainless Steel Bolls
PVC Riser with Grammet(s)
Sb Ground
Slope
(bond to tank adapter with
Away from Riser
recommanded adhesive)
Conduit to
Discharge Assembly
Canlyd Pond
Flexible hose
Effluent Oiechorge
3 TANDETAIL arra
Tank Adapter (cost or bofted)
Loved Control
Flag Assembly
Check Valva (optimed)
Pump
Port
— Placed on Concrete Block
• 0
PITKIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT
Percolation Test and Soils Data Form - TABLE 1 - PROJECT 1718
Performed by All Service Septic, LLC
PROFILE PIT Date of Test: 5/25/2010
0 - 1.0' Root Zone, Sandy Clay, Brown to Dark Brown
1.0'-8.0' Clay, Sandy, Silty, Stiff, Scattered Rocks (up to 1ft diam) Moist
Brown to Red
No Groundwater or Bedrock was Encountered
Hole
No.
Hole
Depth (in.)
Interval
(min.)
Measurement at
Start of Interval
(in.)
Measurement at
End of Interval
(in.)
Change (in.)
Percolation Rate
(min./in.) MPI
1
39
20
1.25
3.00
1.75
20
3.00
4.00
1.00
20
4.00
4.50
0.50
20
4.50
5.00
0.50
20
5.00
5.50
0.50
40
20
5.50
6.25
1.00
2
38
20
2.25
4.00
1.75
20
4.00
5.25
0.75
fill
20
4.75
5.75
1.00
20
5.75
6.75
1.00
fill
20
3.00
4.25
1.25
20
4.25
5.25
1.00
20
3
33
20
2.00
4.00
2.00
20
4.00
7.25
3.25
20
6.00
dry
fill
20
3.50
5.75
2.25
20
5.75
dry
fill
20
3.25
4.25
1.00
20
AVG = 27 MPI
/i�
I
�v
U
tanK
7I
Carla Ostberg
From:
Cari Anne Holcomb
Sent:
Wednesday, June 02, 2010 9:14 AM
To:
Carla Ostberg
Subject:
RMI OWTS Permit
Attachments:
RMI_failedseptic.doc
Carla:
Attached is the exemption letter for the failed RMI septic. The replacement system does not need to be installed within
the square shown around the duplex, as it is not a 1041/Activity Envelope Review, just a'condo' map. I cannot locate any
recorded envelope for that parcel OR development.
Thanks
Cad Anne Holcomb I Planner
Pitkin County Community Development
130 South Galena Street, 3rd Floor
Aspen, CO 81611
t 970.920.50921 f 970.920.5439
CadAnne. Holoomb(d.co.oitkin.co. u s
l�
0
9
PITKIN COUNTY
COMMUNITY DEVELOPMENT DEPARTMENT
130 South Galena Street
3'" Floor
Aspen, Colorado 81611
(970) 920-5526 FAX # (970) 920-5439
June 2, 2010
Rocky Mountain Institute
1820 Folsom Street
Boulder, CO 80302
RE: Land Use Approval for Replacement Septic System
(PID #2467-344-00-001, 30 Shining Mountain Way)
To Whom It May Concern:
After reviewing your general location for the replacement septic system at the above referenced address, it has been
determined that these systems will not encroach into any constrained areas identified in Chapter 7 of the 2006 Land Use
Code.
It should be noted, however that the development and activities of this system are located above Capitol Creek. This
creates an area where extra sensitivity should be taken to prevent degradation of riparian habitat and water quality.
During our meeting on October 30th, it was represented that the leech fields will be located in a flat area void of trees and
shrubs more than 100' from the high water line of the creek. Because of this location your proposal can be exempted
from formal planning review pursuant to section 7-10-30(b) of the 2006 Land Use Code.
The Lot is subject to standards for development in a scenic view protection area. These standards pursuant to section 7-
20-120(d) can be found in the 2006 Pitkin County Land Use Code. Because the septic system is located underground,
the development itself is exempt from review; however, all areas which are disturbed by activities related to the septic
system will need to be mitigated as noted below.
Compliance with the following conditions is strongly encouraged based on the scenic view area:
Conditions
1. The replacement septic system shall be located and designed exactly as required by the Environmental Health
Department. Any changes or expansion of the system shall require future review and a new land use
exemption/approval.
2. No development or activity associated with the septic systems shall be allowed within the setback areas of the
lot.
3. All areas disturbed by the installation of the system shall be re -vegetated with Pitkin County approved grasses
within one growing season of the project's completion. [
4. Development shall not result in sewage outfalls or point or nonpoint sources of organic and inorganic pollutants
that have the potential to degrade water quality or to otherwise degrade the aquatic habitat.
Be advised that all other zoning and building codes and regulations are applicable. This exemption is not vested and may
not be applicable at the time of permit submittal. Please be advised that you must comply with all the conditions of the
OWTS Construction Permit. Provide a copy of this letter to Environmental Health as proof of your Land Use approval to
obtain your Septic Permit.
Additionally, if you have any questions or concerns, please feel free to call me at 970-920-5092.
Sincerely,
6.,: 12.,... P64, 1
Cad Anne Holcomb
Planner
Community Development
Pitkin County
130 South Galena Street, 3rd Floor, Aspen, CO 81611
970.920.5092 (Phone) 970.920.5439 (Fax)
cariannehAco.oitkin.co.us
-)U
621
r.
ViCiNfTY MAP
:• ib 58•E 22: JC
1 \
Ntt ,
_1 c
I .. •- <h na
'0
ei_�a.a • ..r:5
„ Iiocx aco
xo ace
rkl�
rel
MAP
FOR
OLD SNOWMASS CONDOMINIUMS
LOCATED IN TRACTS 81 & 82, SECTION 34, TOWNSHIP 8 SOUTH,
RANGE 86 WEST OF THE 6TH PRINCIPAL MERIDIAN
PITKIN COUNTY, COLORADO
a '
i
c=3n39 or '
P•3o ?• '
>• perN s-2Eb�''_
� 69 3E' 1
�HUILMC, A (D(PLE%'
_v
KKBNA
t®
pAce .
_._ePr..ee .z Necew:Nc
t LlaiY Aad 9lcroz6.z O: i]tklaac .f.i•"C 1 Ckl•
�� •� V lKIt I 4:a•�.cok_yp_ m. Pa9�E
.nno
OLD SNOWMASS
CONDOMINIUMS
;OCAtEc IN TRACT. e, E sa,
aQCTIQN pa. T. sa.. R.*EW..
OF TME .m PAMCIVALYearoub
rrtpN COUNT', .CICOAha
•/5J
1-,--
AVVIT0. a.. T168 I ^low..
of THE
,Mmm
ca"�m"kclpl
uwTv. tote"" p