NSITE WASTEWATER TRET SYSTEM (OWTS)
Etter CONSTRUCTIO MIT
0405 Castle Creek Road, Suite 10 Aspen, CO 81611
Phone: 970.920.5070 Fax: 970.920.5077
Permit #: 08012 (replaces 01015) Parcel ID #: 2643-043-01-006
Permit Issued: ❑ NEW ❑ REPAIR ❑ REMODEL/ADDITION ❑ TANK ONLY ❑ FIELD ONLY
❑ AMENDMENT
Owner(s): Kevin Davis 01 oe
Property Address: 701 Valley Downs Rd
Legal Description: Lot 10 Aspen Valley Downs
Size of Lot: 10 S Ded Accesso UYES
Size of Building: 9,000 Size of Access t J 1200 Sq. Ft.
System is designed f r a I o b rooms: 6 bedroom in the main house and 2
bedrooms in the {Je aretak nit. System is signed under the old ISDS Regulation,
Revised 2001.
Designed By: All ervi a tic roject #: 1455 Dated: 2/27/2008
Phone #: (70-61P-5033 1 41 Mailing Address: P.O. Box 2844 -Glenwood Springs - CO - 81602
FaxXumTa
303-216- Email Address: toetzlCaDcomcast.net
PerLTA 0.95 file Ho na Depth to Groundwater or Bedrock: na
Min Minimum Absorift Area: 2528 sf
mit Conditions Lff
This O S struction Permit is approved on thtccspi n of com a engineer design as submitted with the application and the
1p
specific cited above. AAnnn cchhanges mustJ�a roved by this De an sign engineer prior to construction.
91
This Permit must be ke 3R9 during i tallatio�n. The a st do a plin of the installation and submit an "as -built' letter to
this Department. s nmenso be called inspe minimum of 48 hours notice.
Minimum horizon al stancen ccc000mponents of the system and physical features shall conform to the requirements of the Pitkin County
OWTS Reoulatio
This permit is conditiorW pon the property owner(s) providing for the regular inspection, cleaning, and maintenance of the system by qualified
personnel, in accordance with the manufacturers recommendations and the requirements of the Pitkin County OWTS Regulation.
This is a TANK ONLY permit to add a 1000 gallon single compartment septic tank after the existing 1000 and 2000 gallons tanks to
serve the 6 bedroom main house. The existing pump in the 2000 gallon tank will be placed in the new tank. An existing 1000 gallon
tank serves the caretaker unit The engineer is using a LTAR of 0.95 and has stated that the existing absorption beds of 2790 sf are
sized to serve 8 bedrooms.
THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN COUNTY OWTS
REGULATION. INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE.
Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby
given to the property owner(s) to perform the work indicated in accordance with the Pitkin County OWTS Regulation. This Permit
will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built' drawing must be
submitted aapproved by EH/NR before final approval of the system will be is ued
=. /
Issued By: , Y L� IL/ /f-" Date: U D UO Expires: 0 q b
Installer: V - License #:
I Final Approval Issued By: Date:
C4 �SormsC,
.91
��
3 /-7/o9--
CIZIR:
ONSITE WASTEWATER TREATMENTSYSTEM (OWTS)
CONSTRUCTION PERMIT APPLICATION
0405 Castle Creek Road, Suite 10 - Aspen, CO - 81611
Phone: 970.920.5070 Fax: 970.920.50 77
Parcel ID# (available from the Pitkin Cou
970-920.5160 or at www. i[kinassessor. r
ce
l _ _
a(Q 3 D� 3
V 0 Q
Purpose of Permit
❑ NEW
UE
M
ONLY
Cost of System Repair or RemodellAddition (approximate):
Fax Number.
SIS— 9?5—
0
Property Address:
orms ons p.
Lot O
Filing:
Subdivision:
e
,
Size of Building (square feet):
OOO
Properly Owner(s)':
f
Email Address:
Owner's Me I g=k
T
❑ NO
City, State. Zip: A (�
/
1P / l
Home ho�Sse:
ctiu - cS7
Business Phone: _
CIZ-5-
'Contact informabon must be provided for the owner signing this application.
ct Person/Applicant (if not owner):Company:
r5/1A-7;'
C!
7o—,T
Conte lio t Mailing Address:
7-7 G. ,4E L; i
Z f
City, State, Zip:
GJ
Cell Phone: _
Business Phone: -17-7 `
Fax Number.
SIS— 9?5—
0
Email Address:
7 E: AL ;
orms ons p.
Building Permit # (if applicable):
ate
LM Size (in acres): O
,
Size of Building (square feet):
OOO
Number of Potential Bedrooms:
Detached Accessory Unit? YES
❑ NO
Size of Accessory Unit (square feet):
Oa
Number of Potential Bedrooms In or Fixture List for the Accessory Unite A
Water Source:
PRIVATE WELL
❑ SURFACE WATER
❑ SPRING ❑ COMMUNITY/PUBLiC WATER SYSTEM
Name of Community/Public ter System (if applicable):
Engineering Finn:
Job Number:
Phone Number. 'Number
Mailing Address:
Cty, State, Zip:
w o nZ
PLEASE READ BEFORE SIGNING:
I certify that the above information is complete and accurate and that I have provided complete and accurate information in all of the documents
included in my application package. I acknowledge that EH/NR may revoke any permit I am issued if my application is found to contain any
inaccurate, false, or misleading information. I understand that no construction may be undertaken on an OWTS until an OWTS Construction Permit
is issued.
Owner Signature:
Date.
Applicant SignaWre:
Date:
FOR OFFICE USE ONLY,
Received by EN/HR Staff:
Fee &Receipt # I
1J�h"
Date:
orms ons p.
ate
Tom Dunlop
From:
Sent:
To:
Cc:
Subject:
Kevin Davis, #1455
0 0
Tim Petz [tpetz1@comcast.net]
Wednesday, March 03, 2010 5:49 AM
Tom Dunlop
Bryan Daugherty
Re: Expired OWTS
They wanted to add a bedroom. No construction has taken place, they are in a hold position. I will let them
know there permit has expired.
Tim Petz
All Service septic, LLC / ITS, Inc
PO Box 2844, Glenwood Springs, CO 81602
970-618-5033
6147 Braun Court, Arvada, CO 80004
303-908-7823
FAX 303-216-2796
---- Original Message -----
From: "Tom Dunlop" <Tom.Dunlop@co.pitkin.co.us>
To: tpetz1@comcast.net
Cc: 'Bryan Daugherty" <Bryan.Daugherty@co.pitkin.co.us>
Sent: Friday, February 26, 2010 2:31:42 PM GMT -07:00 US/Canada Mountain
Subject: Expired OWTS
Hi Tim,
I am working for Carla a few hours per week while she is on maternity leave. She asked me to review pending OWTS
files. I found a few designed by you and have listed them below with expiration dates and a brief description of what is
needed if I found it noted in the permit file.
Please reply to Bryan Daugherty at the email listed above. His phone number is (970) 920-5076.
1) Brandon Cohen, 8961 Woody Cr Rd, Lot 1 Silver Creek Subdivision, expiration date 6/26/09, your project # 1465
2) Kevin Davis, 701 Valley Downs Rd, Lot 10 Aspen Valley Downs, expiration date 4/7/09, your project # 1455
3) DJ, LLC., (Bower), 722 Woody Creek Rd, expiration date 10/17/08, your project # - unknown
4) Bill and Nancy Hill, 6889 Capitol Creek Rd, expiration date 2/6/08, your project # - unknown, note in file said the
pump was not wired.
5) Helvetica Endevors, 1654 Castle Creek Rd, Lot 2, expiration date 5/18/08, your project #- unknown, note in file
said a well abandonment form was needed as per their new well permit. This note was dated 9/25/09
6) Brooke Paulides, 200 Sopris Creek Rd, expiration date 9/11/08, your project # - unknown, note in file said you
were to follow up with the owner indicating the septic system was actually connected to the house. This note
was in an email you sent to Carla on 7/15/08
7) William Russell, TBD Hwy 133, EI Rancho Deluxe Lot 3, expiration date 10/24/09, your project # 1537, note in file
said the septic system was not hooked up to the house, there was no inlet T, and inspection port covers were
needed
E
8) Salvatore Rubino, 1101 Coal�ek Rd, expiration date 8/12/09, your projo# 1139
9) Stella Polare, LLC, 44010 East Hwy 82, expiration date 6/24/09, your project # 1260
10) W/1 Lot 2 LLC, c/o Gerry Hazelbaker, TBD Byers Court, W/1 Ranch Lot 2 Filing 5, expiration date 4/22/09, your
project # 1379
Thank you, Tim
Tom Dunlop
q
0
Nancy Mackenzie
From: Brad Elliott [brad@bearchitect.com)
Sent: Monday, March 10, 2008 4:20 PM
To: Nancy Mackenzie
Subject: Fwd: Ken Davis Aspen Valley Downs Lot 10
Nancy,
Here is the email approval from Michael Kraemer.
Thank You,
Brad Elliott
Brad Elliott Architect, Inc.
970-927-7620
0204 Park Ave. Suite 2F
Basalt, CO 81621
brad@bearchitect.com
www.BEArchitect.com
Begin forwarded message:
C
> From: "Michael Kraemer" <michaelk@co.pitkin.co.us>
> Date: March 10, 2008 4:03:03 PM MDT
> To: <brad@bearchitect.com>
> Subject: FW: Ken Davis Aspen Valley Downs Lot 10
> -----Original Message-----
> From: Michael Kraemer
> Sent: Monday, March 10, 2008 3:29 PM
> To: 'Brad Elliott'
> Cc: Nancy Mackenzie
> Subject: RE: Ken Davis Aspen Valley Downs Lot 10
> Brad,
> Thanks, this is the information we needed. You can consider your
> project formally exempted from Planning Review pursuant to 7-10-30(b)
> of the
> 2006 Pitkin County Land Use Code. Please keep in mind that earth tone
> colors and non -reflective roofing materials must be employed for the
> addition to the residence.
> Thanks,
> Mike
> -----Original Message-----
• From: Brad Elliott [mailto:brad@bearchitect.com]
> Sent: Monday, March 10, 2008 3:19 PM
> To: Michael Kraemer
> Subject: Fwd: Ken Davis Aspen Valley Downs Lot 10
• Michael,
> Nancy forwarded this email conversation to me. I just thought I would
> forward you this scan from All Service Septic showing the location of
> the new tank inside the development envelope. We don't need any
> additional Leach field area.
0 0
Nancy Mackenzie
From: Nancy Mackenzie
Sent: Wednesday, December 26, 2007 1:36 PM
To: 'Brad Elliott'
Subject: RE: Davis Septic System 701 Valley Downs Rd
Brad,
I think it would be best if you would bring a full set of plans to our office. We always
check all floors,including the basement, to see if any other changes have been made that
would affect the septic system sizing.
(The permit that was issued in 2001 was for 5 bedrooms in the main house and 2 in a
detached caretaker unit.)
Let me know when you can come in and we can look at it together.
-----Original Message -----
From: Brad Elliott [mailto:brad@bearchitect.com]
Sent: Wednesday, December 19, 2007 11:09 AM
To: Nancy Mackenzie
Subject: Davis Septic System 701 Valley Downs Rd
Nancy,
Here are the plans for the Davis Residence. I have included the Demo Plans as well as the
new plans so you can see what we are adding.
/, 1
0 0
fl l l V0Box 2844
Glenwood Springs, (081602
Ph 970-618-5033
SEflYICt Fax303-2164796
February 27`s 2008
Brad Elliot
C/O Kevin Davis
0204 Park Avenue, Suite 2F
Basalt, CO 81621
Project No. 1455
Onsite Wastewater System Evaluation and Sizing Justification, Existing Davis Residence
Lot 10, Aspen Valley Downs
701 Valley Downs Road
Pitkin County, Colorado
Mr. Elliot,
As requested by Brad Elliot, ALL SERVICE septic, LLC evaluated the existing onsite wastewater
system (OWS) designed by CHURCH, Pro No. 11019, in order to determine if the existing OWS
would accommodate an additional bedroom in the main residence.
CHURCH performed a percolation test in 2000, and prepared an OWS design based on an average
percolation rate. The design was based on 5 bedrooms for the main residence and 2 bedrooms for the
caretaker unit, for a total of 7 bedrooms. The current homeowner is adding a bedroom to the main
residence bringing the total number of bedrooms to 8.
The subject property is located outside of Aspen, Colorado in an area where wells and OWS are
necessary. The subject well is greater than 295 feet from the existing drain field. The subject OWS
consists of three septic tanks and one 2790 SF chamber -drain field, as indicated on the attached as -
built drawing.
Soil samples were collected at the subject site in order to perform gradation analyses and determine a
long -term -acceptance -rate (LTAR). Our sizing of the proposed 8 -bedroom residence will be based on
the LTAR from the soil samples collected. The soil samples, and gradation analyses, indicated the
soils were a sand to a sandy loam. A 0.95 LTAR will be used to justify the sizing of the drain field.
DRAIN FIELD SIZING:
6 bedroom main residence, >6000SF = 1560 gallons per day (GPD)
2 bedroom caretaker unit, <6000SF = 400 GPD
Total loading = 1960 GPD�x 1.75 = 3430 GPD
3430 / 0.95 LTAR = 3611 of required SF of #in field.
30% reduction based on chambers = 2528 SF
Existing drain field area = 2790 SF
The existing drain field will serve the existing residence, including the proposed additional
bedroom in the main residence.
M
• Onsite Wastewater Systems
Pro. No. 1455
Feb 27 2008
Page 2
TANK SIZING:
6 bedroom main residence, >6000SF = 1560 GPD (3000 gallons exist)
2 bedroom caretaker unit, <6000SF = 400 GPD (1000 gallons exist)
MAIN Total minimum gals required = 1560 GPD x 1.75 x 1.25 = 3413 Gals
CARETAKER Total minimum gals required = 400 GPD x 1.75 x 1.25 = 875 Gals
The main residence requires a 1000 -gallon, single -compartment, concrete septic tank to be
installed to accommodate the additional loading, as indicated on plans. The existing pump in
the existing tank is sufficient to serve the new tank and existing drain field. Remove pump and
pump vault from existing tank and place in proposed 1000 -gallon single -compartment tank.
ADDITIONAL REQUIREMENTS
Check the septic tank to ensure the pump is working and that the tank is not overdue for
pumping.
2. Clean the effluent filter.
Check observation pipes to ensure that they are clear and that no liquid is standing in the
drain field.
OPERATION INFORMATION AND MAINTENANCE INFORMATION
The homeowner should pump the septic tank every two years and clean the effluent filter as needed.
Garbage disposal use should be minimized, and non -biodegradable materials should not be placed
into the OWS. Grease should not be placed in household drains. Loading from a water softener
should not be discharged into the OWS. No hazardous wastes should be directed into the OWS.
Mechanical room drains should not discharge into the OWS. The OWS is engineered for domestic
waste only.
LIMITS:
This evaluation is not a guarantee of any future drain field performance, in any way. The design
is based on information submitted. If soil conditions encountered are different from conditions
described in report, ALL SERVICE septic, LLC should be notified. All OWS construction must be
according to the county regulations. Requirements not specified in this report must follow county
regulations. The installer should have documented and demonstrated knowledge of the requirements
and regulations of the county in which they are working.
Sincerely,
ALL SERVICE septic, LLC
---�-7-
Timothy R. Petz
3 copies sent
M
WELL LOCATED
500+ NORTHWEST
OF DRAIN FIELD
�LF�C
[OG= Os 5Rp54
PROPOSED UPGRADE OWS
/2790 SF OF DRAIN FIELD IN SEVEN CHAMBER
/BEDS.
EXISTING TANKS. ONE
2000 -GALLON 2 -COM TAN
FOLLOWED BY ONE
1000 -GALLON SINGLE -CO
TANK WITH PUMP VAULT.
IEDGE OF
DISTRIBUTION /
BOXES
2" PUMP LINE TO DRAIN
AFTER EACH DOSE.
INSTALL A 1000 -GALLON, SINGLE COMPARTMENT
PRECAST CONCRETE SEPTIC TANK WITH PUMP VAULT. \
THE PUMP MAY BE TAKEN FROM EXISTING TANK AND
PLACED IN PROPOSED TANK.
s%
K
M
CONCRETq
WALL
L—I
&BEDROOM RESIDENCE
1000 -Gallon, Effluent Pumping System - Single -Compartment
radar a oacMr wrr PC Ibr .In r
�1
AM ft� ftV I Slrii 9 a.%
cw"b—
Caae Paw
ar• ue —
wa t«'oTn nesya (rra a
wNM 50P'Ia.4
2 -BEDROOM
CDU
GARAGE AND
CARETAKER
40.00'
O
O EXISTING 1000 -GALLON
TANK WITH EFFLUENT
FILTER
Keep drive clear for
/emergency access
MI
5llmttl'�
LOT 10, ASPEN VALLEY DOWNS
SEWER LINE MAY HAVE TO BE
PRO. NO. 1455
RELOCATED IF UNDER NEW
CONSTRUCTION, AND/OR
SERVICE SEPTIC
INSULATED UNDER DRIVES AND
DAVIS RESIDENCE
WALKS.
SCALE
1" = 30'
NORTH
&BEDROOM RESIDENCE
1000 -Gallon, Effluent Pumping System - Single -Compartment
radar a oacMr wrr PC Ibr .In r
�1
AM ft� ftV I Slrii 9 a.%
cw"b—
Caae Paw
ar• ue —
wa t«'oTn nesya (rra a
wNM 50P'Ia.4
2 -BEDROOM
CDU
GARAGE AND
CARETAKER
40.00'
O
O EXISTING 1000 -GALLON
TANK WITH EFFLUENT
FILTER
Keep drive clear for
/emergency access
MI
5llmttl'�
LOT 10, ASPEN VALLEY DOWNS
ALL
PRO. NO. 1455
PITKIN COUNTY, COLORADO
SERVICE SEPTIC
DAVIS RESIDENCE
970-618-5033
FIGURE 1
b ax ren raN Cr•r
r dwnEN
Mwr
1/6-6w, ftW N* to •a Prrw •w
ue W
ww PwY
o aewd Pup
�a qr
Pad
w• Pap art
0.1
dos"�"waowem symam•
Nr rr ••ra
urea. omor
arw-ea
aun•c
awl ya-y�•
nraac
prq eraa
C
01
G
.y
1p
Q.
0
100
90
80
70
60
50
40
30
20
10
0 L
0.01
GRADATION A►NA►LYW
#200 #100 450 430 416 48 44 3/8" 3!4" L1!2' 3"
Gravel - 0%
Sand - 80%
Fines - 20%
Project No. 1455
0A 1 10
Diameter of Particles in Millimeters
SAMPLE A - Sand to Sandy Loam, Dense, Very Moist, Red/Brown
DEPTH - 1.0 feet
MOISTURE CONTENT - 10.2%
100
•
NZ
0
100
90
80
70
60
50
40
30 —
20
10
0
0.01
GRADATION ANALYA1
9200 9100 950 930 416 48 a4
3/8" 3/4" 1-1/2" 3"
Gravel - 0%
Sand - 63%
Fines - 37%
Project No. 1455
0.1 1 10
Diameter of Particles in Millimeters
SAMPLE B - Sand to Sandy Loam, Dense, Very Moist, Red/Brown
DEPTH - 1.0 feet
MOISTURE CONTENT - 9.5%
100
M M
0
Ll
0 0
Nancy Mackenzie
From: Michael Kraemer
Sent: Monday, March 10, 2008 3:29 PM
To: 'Brad Elliott'
Cc: Nancy Mackenzie
Subject: RE: Ken Davis Aspen Valley Downs Lot 10
Brad,
Thanks, this is the information we needed. You can consider your project formally exempted
from Planning Review pursuant to 7-10-30(b) of the 2006 Pitkin County Land Use Code.
Please keep in mind that earth tone colors and non -reflective roofing materials must be
employed for the addition to the residence.
Thanks,
Mike
-----Original Message -----
From: Brad Elliott (mailto:brad@bearchitect.com]
Sent: Monday, March 10, 2008 3:19 PM
To: Michael Kraemer
Subject: Fwd: Ken Davis Aspen Valley Downs Lot 10
Michael,
Nancy forwarded this email conversation to me. I just thought I would forward you this
scan from All Service Septic showing the location of the new tank inside the development
envelope. We don't need any additional Leach field area.
10
LAJ
LOT 10, ASPEN VALLEY DOWNS
PITKIN COUNTY, COLORADO
2790 SF OF GWELL =.V
n-BE
RSANFL
ACt , LENGTH
BE�VMDE
B- 12 CHAMBERS IN LENGTH
2 CHAMBERS WIDE
2-V
L41
LEVEL
-DIINIMUM
DIST El11
POND IF UNLINED
.:g
NOTE:
WELL IS INSTALLED 275 FEET MINIMUM FROM
OWS FIELD
CLEANOUTS ARE PLACED AT 1020 F
INTERVALS
MINIMUM SETBACK DISTANCE FIELD
To POOL- 25 FEET
JOB NO. 11019
NOT TO
SCALE
N CONTOURINTERVAL: 2* -0"
LYONMP PROVIDED BY LINES IN SPACE
GALL- Sil
coNcRtE sEFri
FI ONTHit*
PARKING
........... \
PROP D
RE E
...............
c IT
PR OSED IVE
NET
DU s UNE T K AN\
E ALTE ON E
BE EA PAVE NT.
4D
OWS AS -BUILT DRAWING
0 �
0 1
etaoe ;.
-- \ DWW LOT 7
ruse P#;LcvNE
OT
O >�' \ � '� 1�'��L`i' �' I� pSA. 1'. .fit •�}••�A �ti( 'i :,: 1` \
4Q211 Ar
C7 .(- _ _ Li" .. :r i's{i .y, .i 7 a."' ..i^.,t �• .'a. �" � .�• •.{ ti ,
yT'�N. �' •, _'�^,
!Awl.
,. , _v. •sem -��h�: ',1••',• i'J 'fy'.� ' •> 'r .•,
(ryy�� �,rYi. �'. ••,� e' � t. -• r•r, i!.5 tN�i t•, i.Y"4•'? �'t•�: { j �
� lj.i. _• :.al': \\\ ,• Yf - "f> � . �" •'�'S'` ,'. � I _ Y'•1-'ry ia� „�••' ! < ,, `1 � '
LOT :.10 F�
lk
` ` •� l.! \ \ r 1 �'e,. •j.� If^•.t !': 15't:a-l• K.•�,
r••('�',.4i�>'��: ''.7i,£._r'4:J i`�:
try f of t`Fnt \ _ .� �Y..l!"h.�Y tI r 1 �, � .'! ' a_ .�,,>. a•
rp
! \ iii l \ �'. \� +'"I w• M •! • f • • : t ,.. '• j'r1r"/ {\fy\•i I'. I .' �. .,•'•J,
. •.. ill I / \ \ ``, +'I - I � .> I Y��iry l:p �.l,T �''. _, J • � •'��,•
•
�Loov -t/000
000
y74
ISDS DESIGN CALCULATIONS - for Pitkin
2 g0 /
Owner's Name Parcel ID # .
House Size (sq. ft.) ;M (75 gpd, 100 gpd, or 130 gpd)
Number of Bedrooms in Main House
Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House
Number of Bedrooms in Detached Caretaker unit '
Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit
(If the caretaker unit is ATTACHED, treat as if part of main house.)
Average Daily Waste Flow 1860
State Review Required? no
Perc Rate ' (T)
Design Flow (Q) = # potential bedrooms X 2 people/bedroom X gpd X 1.75
Q-- 3255
Minimum tank capacity 4068:75 gallons
Absorption Area (=Q/5 X SQRT perc rate)
A = 4,013 sq. ft. of absorption area required
259 gravelless chamber units without reduction
# of Perc Holes Required: 3.3441946
QUICK 4
9.87
A =
2006.5168 sq.ft. with 5o% reductionTRENCHES
203 gravelless chamber units with reduction
STANDARD
A =
2006.5168 sq.ft. with 50% reductionTRENCHES
129 gravelless chamber units with reduction
EO 36
126 EQ36 units in TRENCHES
QUICK4-EO36
2007
259
SETBACK FROM WELL
# of feet =
280.4
SETBACK FROM POND, STREAM OR IRRIGATION DITCH
# of feet = 230.4
SETBACK FROM DRY GULCH
# of feet = 205.4
I
t
/ 17 1.75
73Z)
3 2 S�
3'13 `�
UICK 4 9.2
2809.1235 sq ft 30% reduction BED
305 chamber units with reduc.
2809.1235 sq ft 30% reduction BED
181 chamber units with reduc.
225 EQ36 units in a BED
2809
439