HomeMy WebLinkAboutpitkin.eh.247328400041 (1974)(Trailer House Area)Document Layout
(From Most Recent to Oldest Permit)
Permit
Application
Log Sheet/Notes & Photos
Communications
As -built Design
Engineer Design
Soil Information
Water Permit & Information
Second System on property
Third System .etc.
Floor Plans
Please See Building and Land Use Approvals Files for additional information.
2q_1
3
PERMIT NUMBER 720211 PITKIN COUNTY HEALTH DEPARTMENT RECEIPT NUMBER
Owner 7J AL2i <,o ti ' W E STER_o a QP . Phone #
Owner's Mail'in'g Address�0 �x
��'Et�1TI
Contractor PAF-_ P_j So 0 W tSrE j ( / _6 �nP Phone # 612-7-1141
Address --Pc)- )dX '4 ' II I�EP_EQIThl"_I � L -U. H 1 (o 4-?—
Systems Contractor''ss Name t-1 ltiF2.�1 n, j 1k) G`S /T�E2Ai p
Address t 4 �LER'E�1T+1� `�DIU S31(042
Legal Description���n/nlCrd)P T 9 E3ZV) it-) FST' Io-Onpjelu
Lot Size S e of wilding y Use Ta�.t llAiiSES
Number of Bedrooms Z� of Water �u ply �/!✓LL
Type of Individual Sewage Disposal System ST
cP1 C. AK) l� H tj RA.T1,j_1 o t
Type of Soil or Soil Classification (-;a L. f- ct✓ Iv y t_) E� ode Y:"o M.
Proximal Location of Bedrock 4 S L- &E
i J ,
Proximal Location 4P -Ground WAt4aLr Table ZX) _ F: -F- E: -T- CES T: LA�a
Owner's Signature Date U
PLOT PLAN: L Qe O y
GL�_J o7A � u
Z'1u i.c�1
AP
vj
Percolation Test Data
Minutes per inch
M,inim,Vum Rgcommended Absorption System Size �y X IL'J
\,_Coll r� Jj 1
MiMimum Rec bmmen d T'a> Size - L \_ ff4
Permit applicat valid one year from ate. pp ica`I l
after lower port' n is completed and signed by the Sani
CONSTRUCITON SITE.
Vi
final only
IPPRM AT THE
Sanitarian
Drawing of system on back)
.` COLORADO DEPARTMENT OF Holl
Water Pollution Control Division
4210 East 11th Avenue
Denver, Colorado 80220
APPLICATION FOR APPROVAL OF LOCATION FOR SEPTIC TANK SYSTEMS
Applicant (Owner): Pette Kiewit Son Commany-
Mail Address: Box 16li-S Star Route , City: Meredith. Colo. Phone: 927-3663_
A. INFORMATION REGARDING PROJECT SUBMITTED FOR REVIEW:
Attach separate sheets or report showing entire -area with respect to surrounding
areas, topography of area, habitable buildings, location of potable water wells,
soil percolation test holes, Boll profiles in test holes.
1. Location of Facility: County_—,,tk1. _ City or Town %rrie
Legal Description T Lot Size:
2. Type of area and facility - Number of persons served:
Subdivision Motel Restaurant Trailer Court X
Other:
3. Source of domestic water: Public (name):
Private: Well X Depth Other Depth to first ground water table 6
4. Is facility within boundaries of City or Sanitation District: NTo
If so name:
5. Distance to nearest sewer system:
Have negotiations been attempted with owner to connect:
If rejected, give reason:
6. Rate of absorption in test holes in minutes per inch of drop in water level after
holes have been soaked for 24 hours:
7. Name, address and telephone of person who made soil absorption tests:
8. Name, address and telephone of person responsible for design of the system:
P. E. Freeland, Peter Kiewit Sonst_ Company, Meredith, Colorado 816h2 927-386 _
9. Est. bid opening date: Est. Completion Date: Est. Project Cost: L1800.00
Date: October 9, 1971
Signature of Owner
N
B. SIGNATURES FOR 1-0r,4bOVEW4iFNT OFFICIALS: Tne and ignad have revicaed the
proposal for the ion of th-- above-described �epTic tank system and r' H
RECOM,IIEND APPROVAL or DIS"PPROVAL in the space- provided bele-+:
DATE APPROVAL DISAPPROVAL
/—% /_—_%
Signature for Local health Department
Signature for liayor or City Manager
Signature for County Commissioners
Comments:
Signature and Title
Note: The applicant must o`aain the comments and signature. of at least one of the above.
C. FOLLOWING FOR STATE HEALTH DEPARTMENT USE: Recosmiendations of the District Engineer
D. ACTION BY THE COLORADO WATER POLLUTION CONTROL CONMISSIM :
I 3 WP -10 (Rev. 5-70-100)
q
OLORADO DEPARTMENT OF HEALTH •
DIVISION OF ENGINEERING AND SANITATION
ACT I V I T Y RE PORT Code 12
Section County
FILE REFERENCE:
INDIVIDUAL OR
ESTABLISHMENT: garrison—Wa,+P Li rip,.,,+;n„
ADDRESS:
NARRATIVE:
I talked to Larry Form an about the Norrie Colony of the
Harrison -Western Corporation. They have installed a sewage disposal system
without our knowledge or approval. They did make application for a permit
and ppy a permit fee; however, nothing has bedn done since then. They called
for a perc test, but when Bob got there, the holes were not properly prepared.
On a visit to the housing area 6t Norrie Colony, it was found
that 2 treatment plants have been put into the ground and backfilled. At
least one is a Cavitette home aerated treatment system, which did not appear
to be electrically connected. It is hard to tell what they have done as far
as a leaching field is concerned. There has been some disturbance of the
ground in the area where they expected to put the field, but we have no idea
what that systgm was..
1
LETTER TO FOLLOW: ( ) OTHER
DATE: , 19�
ES: 7 (Rev. 6-70-100)
REPRESENTATIVE:
IRLORADO DEPARTMENT OF HEALTH •
DIVISION OF ENGINEERING AND SANITATION
ACT I V I T Y RE PORT Code 19
Section57
County
FILE REFERENCE:
INDIVIDUAL OR
ESTABLISHMENT; us„,eenn W>e+o (n�1L�+y�y
ADDRESS: m.
NARRATIVE:
I spoke to Doug Spra.etz of Harrison -Western concerning the
sewage disposal problems up there brought to our attention by the forest
service. I can find no evidence that the existing facility is polluting
either the wells or the river. Harrison -Western paid for a series of
lab tests done on a river survey, above and below the leach field and
both results came back with 5 day b.o.d. less than 1 and a fecal
coliform count less than 1. I could find no evidence of ponding or
breaking out along the hillside. The septic tank was located and
excavated out. It appears to be a 1,000 gallon metal tank. Judging
from the location and depression, it appears there's a 2 foot wide
trench, 100 feet long, running toward the river, but still quite
a ways from it.
Doug and I went over the problems that could result
as a consequence of using this outdated, and in all probability,
undersized system. We reached the conclusion that it would be best
to go ahead and install the two Cavitette units, and design a leach
field sized according to the sewage flow.
There are only four people in permanent residence now,
and they don't anticipate any more residents in the next month or two.
The original purpose of the trip was to run a perc test, but there
were no holes dug.
LETTER TO FOLLOW: ( ) OTHER RECOMMENDATIONS:
DATE: utiF , 19 /Y”. REPRESENTATIVE:
5 ES: 7 (Rev. 6-70-100) ����iii
2ARIAN
�✓Bh4�rc ZQ
COLORADO STATE DEPARTMENT OF PUBLIC HEALTH
DIVISION OF SANITATION Code l l R l
Section ACTIVITY REPORT County 57
FILE REFERENCE: Private Sewage dispnSal and water canitatinn
INDIVIDUAL
OR
ESTABLISHMENT: Norrie Cnlnny
NARRATIVE:
I travelled with Greg Misbach to the office of the Norrie
Colony Constnuction Company. We found no one there in authority, since the
office had moved to the construction site. We found that 2 steel units had
been installed, but I don't know if only 1 or both is a Cavitette aeriated
unit. They are connected plumbing -wise, and are in use. Some scratching around
has been done in the leaching field area, but there was no way to determine
what was done there.
I obtained a water sample. A chlorinator was amt in evidence,
but the stock tank was nearly empty. The level was below the intake of the
PUMP -
LETTER TO FOLLOW: ( ) OTHER RECOMMENDATIONS:
Lp DATE: 11/12 , 19 74 REPRESENTATIVE:
ES: 7 (8-53-50)
0
0
1208 QUAIL STREET • DENVER, COLORADO 80215 • TELEPHONE: AC 303-238.1223
HARRISON WESTERN CORPORATION Contractors• Engineers
P.O. Box 4, Meredith, Colo. 81642
Department of Environmental Health
Pitkin County
Attn: Jim Rourk
506 E. Main St.
Aspen, Colo. 81611
Gentlemen: NOV 17 1974
c:t�r.Jf,,SFEP� -
Subjects New septic system SAN'TARM
Norrie Trailer Camp C, a
There seems to be some misunderstanding regarding our newly ins
septic system. Enclosed in this letter is the follows presentation:
1). Pitkin County permit with perc test data;�this was submitted
to Company Sanitary Engineer to be used in his design).
2). Calculations and design of leatch field and septic tank
placement from Harrison Western Sanitary Engineer.
3). Letter of approval on the above mentioned calculations and
plans by the U.S. Bureau of Reclamation and the U.S. Forest
Service.
4). Copy of purchase order for piping.
Installation began September 26, 1974 and was completed on September 28,
1974. Prior to this we notified your office of the impending installation.
The Cavatte septic tank is installed and we are awaiting delivery on a
single phase motor to drive the impeller. Until the motor is installed and
operable, we are pumping the tanks on a monthly basis.
The U.S. Forest Service has been sampling the springs at Jameson's place
(below the leatch field) and has found no contamination before or after the
installation.
We therefore believe we have a good serviceable installation and are and
will take whatever steps necessary to maintain its operating efficiency.
Very truly yours,
HARRISON WESTERN CORPORATION
Pat Loughry
Project Manager
Cunningham Tunnel Project
PL/ms
/NFC.UENT FAPOM
TR'AILErP5 ! DRY NO(/56
I
I
I
o N
'
4" SOLID ?-YC MAIN —
CAYi7E�TE SEPT/C 7-,4NKx
°
SLOPE r" YER 4/NE4G
W/fH PEKA7/NAE'
G: RAT/OA(
M6CiV'A�/SM�
H
y..'.
•,
4.4"
':.�...
SOLID PVC I -4r45 AL
.. ,
.SLOPE � FER Fool
L
y . , a. p, •.:
0.-R
•
4
r
,
KQ�
0
l0.
i