HomeMy WebLinkAboutpitkin.eh.264304401001 (2000)Document Layout
(From Most Recent to Oldest Permit)
Permit
Application
Log Sheet/Notes & Photos
Communications
As -built Design
Engineer Design
Soil Information
Water Permit & Information
Second System on property
Third System .etc.
Floor Plans
Please See Building and Land Use Approvals Files for additional information.
Aspen/Pitkin Environmental Health Department
Permit for an Individual Sewage Disposal System
130 S. Galena St. Aspen, Colorado 81611
Phone 970-920-5070 / FAX 970-920-5074
Permit # ;?, D O 1 z% Parcel ID # 2643-044-01-001
Type of permit New( ) Repair( ) Addition to House( X ) Add attached caretaker unit
Name of Owner Jack & Harriet Stievelman
Street Address 120 Running Mare lam - Rd
Property legal description Lot 4, Aspen Valley Downs
Size of lot -20 acres Total square footage of the house 13,464
Water source Private Well
# of bedrooms in house # of offices, lofts & similar sized rooms in house 5
Caretaker unit ATTACHED Total square footage of the caretaker unit
# of bedrooms in caretaker unit 1 # of offices, lofts & similar sized rooms in caretaker unit
Designed for what # rooms (list) (6) SIX TOTAL - 5 BR in main house and 1 BR in attached caretaker
Permit information
Designed by Church & Associates, Inc.
Mailing Address 4501 Wadsworth Boulevard, Wheat Ridge, CO 80033
Perc rate_ Profile hole depth 8' Depth to groundwater or bedrock +8'
mac. Septic tank capacity need 3413 total Absorption area need 2619 (30% red. for infiltrator=1833)
YK_& L: "2 Sri 2 o 0 d d -,:,� wA��*,,.//���f� .li. ..�QcsC'J . Q. c�to�y��. �ce� /1 1 Z
Septic permit approved per com lance with the engineer de gn an pecifica ions ted March 28, 20 0. Any
changes must be approved by this apartment and the des' n engineer prior to them Xing made. The ngineer
design for 5 bedrooms (ISDS Permit 9010) has been i tolled.. This design is for the mpleted s tem for 6
bedrooms (the original 5 BR and the ne 1 BR attache caretaker unit). It shows the finish d incre ed size of the
drain fields and tanks and the increased se ack dist ces to wells (238 ft) and irrigation/de8 ft)The first 2,000 gallon concrete septic tank will re in. The second tank will be replaced0gallon two
compartment concrete septic tank with a dosing ip on. Two beds will be increased by 6and the third
bed will be increased by 9 chambers for a to increa of 21 chambers. This will bring tbeds up to a
total of 120 chambers.
lo(
Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin
County ISDS regulations.
The engineer must do a final inspection of the installation and submit an as -built letter to this department. This
department must also be called for an inspection with a minimum of 48 hours advanced notice.
Permit approved by: Date: Y a o v
Plans and specifications of the pr osed individual sewage disposal system have been reviewed and are considered
satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin
County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was
issued unless system construction has commenced or an extension has been approved in writing by the Department.
As -built drawings must be Included with this permit before the final approval will be issued.
Installer:
Final Inspection
Date: � /
Mi
30-00 THU 04:44 PM ASPE�ITKIN ENV HEALTH AX:970 920 5n74 PAGE 3
ASPENfrI7K1N ENVIRONMENTAL HEALTH DEPARTMENT
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM
130 S. Galena St., Aspen Colorado 81611
Phone 970-920-5070/Fax 970-920.5074
Name of OWNER 0 AEPOT
Owners Mailing Address
Business Phone: 2 - Home Phone:
Primary Contact Person (all communication regarding this permit will go through this person)
Name t` • IJ tb
Companv wl 'J A `J /V -G
Contact Mailing Address %i 15
Business Phone .Cell Phone : Fax
Parcel ID # (available from assessor's office
at 920.5160 or at www.aspen.com/assessor/)
Street address of property
Legal Description! Lot �— ,Block
,Filing ,Subdivision
Size of lot: 1 20 acres. Type of proposed structure: 9615 Size of oldg. envelope:
Total square feet of house I ??4•� # of bedrooms in house
# of offices, lofts 8 similar sized rooms-mssiin house
Caretaker Unit: Attached) Detached ( )
# of bedrooms in caretaker unite 46" # of
Total area(sq. ft.) of caretaker unit
lofts and similar size rooms of caretaker unit
Q -1 -
Size
L
Permit is for: New Home 1/ ) Repair due to failure ( ) RemodeUAddition ( ) Emergency use ( j
Water: Private well ((X ) Spring ( ) Stream ( ) Community/Public Water System ( )
If community system: Name of system
The fee for a ISDS application is $330 for a permit that takes 6 hours or less for the department to approve. If approval takes
longer than o" hours, a rate of S55 per hour will be charged. The maximum fee is $1000. The basic fee of 5330 is due at the time
of application. The remainder, if any, will be due in two stages: first. at the time of issuance of the ISDS permit; second, before
final approval of the ISDS permit.
Application for an individual sewage disposal systr -, is hereby submitted. I hereby certify ,hat the above information is true and
accurate and that I have provided true and accur - information on locations of all existing and proposed wells, contour
intervals, buildings, property lines, ditches, slopes, waterlines, springs, suction or irrigation lines, drinking water cisterns, drain
tiles, irrigation ditches, lakes, water courses, streams, floodplains, dry gulches, and existing septic systems. I hereby certify
that any such features not shown on attached site map are not present. Issuance of the permit does not imply the approval of
any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all
approvals and permits have been obtained.
The Aspen/Pitkin Environmental Health Department, Pitkin County and employees of these agencies will be held harmless
should the individual sewage disposal system fail or malfunction. The permit to construct is issued on information submitted by
the applicant or his/her representatives. The owner assumes full responsibility in case of failure of the system.
Signature of
Date
Y
3 Received by Receipt 1 1 Date
G:\eh\isds\isds ap p.doc
7
ASPENOMN ENVIRONMENTAL HEALTH DRTMENT
APPLICATION FOR INDIVIDUAL SEWAGE DISP ,3L SYSTEM
130 S. Galena St., Aspen Colorado 81611
Phone 970-920-5070/Fax 970-920-5039
Name of OWNER TAA y, "AO 4 Ai KIT- trnSNJM MA►J
Owners Mailing Address CIO VCr#-.
Business Phone: t2'2'5— 6131 Home Phone:
Primary Contact Person (all communication regarding this permit will go through this person)
Name ur- IL. 13ANu071
sn
Company lwva' -rtZ 'J-'N`_`I_ r.1�Xi�.• (I�IC^
Contact Mailing Address Vs u p '+ �CbO �✓={O�j g �'
Phone: Fax: " LA2-
Parcel ID X (available from assessors omce
at 920-5160 or at www.aspen.com/assessart)
Street address of property ry
Legal Description: Lot —+-- ,Black
,Filing Subdivision
Size of lot: 4 ZO acres. Type of proposed structure: �_ Size of bldg. envelope:
Total square feet of house j3 � (,o4' * of bedrooms in house S
# of offices, lofts 8 similar sized rooms in house
Caretaker Unit: Attached ( ) Detached ( ) Total area(sq. ft.) of caretaker unit
Permit is for. New Home ( X ) Repair due to failure ( ) Remodel/Addition ( ) Emergency use ( )
Water. Private well ( $j Spring ( ) Stream ( ) Community/Public Water System ( )
If community system: Name of system
The fee for a ISDS application is 5330 for a permit that takes 6 hours or less for the department to approve. If approval takes
longer than 6 hours, a rate of $55 per hour will be charged. The maximum fee is $1000. The basic fee of $330 is due at the time
of application. The remainder, if any, will be due in two stages: first, at the time of issuance of the ISDS permit; second, before
final approval of the ISDS permit.
Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information is true and
accurate and that I have provided true and accurate information on locations of all existing and proposed wells, contour
intervals, buildings, property lines, ditches, slopes, waterlines, springs, suction or irrigation lines, drinking water cisterns, drain
tiles, irrigation ditches, lakes, water courses, streams, floodplains, dry gulches, and existing septic systems. I hereby certify
that any such features not shown on attached site map are not present. Issuance of the permit does not imply the approval of
any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all
approvals and permits have been obtained.
The Aspen/Pkkin Environmental Health Department, Pitkin County and employees of these agencies will be held harmless
should the individual sewage disposal system fail or malfunction. The permit to construct is issued on information submitted by
the applicant or his/her representatives. The owner assum full responsibility in case of failure of the system. q
Signature of applicant Date 7
Received by Receipt Date 13 9�j
q
•
•
�a
•
Tim Petz, 05:28 PM O1/09/20W?E
Steivelman
From: Tim Petz <tpetz@geo-church.com>
To: "Nancy MacKenzie... <nancym@ci.aspen.co.us>
Subject: RE: Steivelman
Date: Tue, 9 Jan 2001 17:28:09 -0700
X -Mailer: Internet Mail Service (5.5.2448.0)
0
It is probably better in the second tank, ALTHOUGH, They are using a dosing
siphon (which is very incompatable with a screened vault filter) so a filter
is placed in the first tank. The design of the Biotube filter allows only
the "clear zone" liquid into the filler (due to the holes in the filter half
way down the filter housing) and not the 'scum! or 'sludge' layer. It will
not clog anymore than on the inlet of the second tank. TIM
-----Original Message -----
From Nancy MacKenzie [m&ilto:nancym@cias P!en.co.us)
Sent: Tuesday, January 09, 20013:17 PM
To: tpetz@geo-church.com
Subject: Steivelman
Hi Tim,
Besides everything else up there, I was wondering if it was correct to have
the effluent filter on the outlet of the first tank. Wouldn't "it" not have
time to settle out and clog the filter more quickly and be more of a
problem than if it was on the second tank?
Nancy MacKenzie
Pitkin County Environmental Health
X5076
Page I of I
4
Printed for Nancy MacKenzie <nancym@ci.aspen.co.us> 01/10/2001
NPio'ounty Community
Development
Nancy MacKenzie
Pitkin County Environmental Health Department
Subject: Stievelman Septic System
Dear Nancy,
I visited Lot 4, Aspen Valley Downs (Stievelman Residence) on 1/11/99 and determined that so
long as the septic system complies with Environmental Health stream setback requirements from
Salvation Ditch, there are no 1041 concerns with septic system development outside of the
approved building envelope. This does not have the effect of allowing development other than the
septic system outside of the building envelope.
Gabe Preston
Planner
CC: Jeff Hancox
__ ---l-
:-
.._
r,
0
Aq_qnnintP.
ENGINEERS & GEOLOGISTS
January 24, 2001
Robert Trown & Associates, Attn: Jeffery Hancox
PO Box 6820
Snowmass Village, CO 81615
Subject: Installation Observation, Proposed Stievelman Residence
Lot 4, Aspen Valley Downs
Pitkin County, Colorado
Job No. 10559
Mr. Hancox,
0
As requested, we observed the installation of the onsite wastewater system (OWS) for the site on January
3, 2000 and January 16, 2000. The OWS was designed under our Job No. 10559, dated January 11, 2001.
The system includes the installation of a 2000 -gallon, two-compartment, precast concrete septic tank with
an effluent filter on the outlet, followed by a 2000 -gallon, two-compartment precast concrete septic tank
with a dosing siphon. Six chamber -beds were installed, as indicated on Figure 1. Beds `A' have 2 rows
of 1 I chambers, and beds `B' have 3 rows of 1 I chambers, for a total infiltrative area of 2387 square feet
(SF). A distribution box with flow regulators was installed to distribute effluent among the chamber -beds.
The distribution box is large enough to handle the discharge from the dosing siphon.
The irrigation ditch to the north of the drain field has been lined appropriately with a PVC liner 188 feet
from the drain field. Photos are included as Figure 2.
The components of the OWS were installed in conformance with our plans and specifications.
If there are questions or if we may be of further service, please call.
CHURCH and Associates,
2 copies sent
copy to APEHD, Attn: Nancy MacKenzie (original photos to county)
copy to Dakota Development Group, Attn: Lee, 309A Aspen Airport Business Center, Aspen CO 81611
DENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 80033 CASTLE ROCK 303.660.4358
303.463.9317 Fax: 303.463.9321 EVERGREEN 303.816.1455
) LOVELAND 970.663.2124
LOT 4, ASPEN VALLEY DOWNS /
PITKIN COUNTY, COLORADO /
W /
/ „W l
whn
ENCASE WATER LINE
WITHIN 10 FEET OF PROPOSED
DRAIN FIELDS WITH SCH 40
PVC PIPE 2 INCHES GREATER
IN DIAMETER THAN WATER LINE AND
WATER TIGHT CONNECTIONS
(IF NECESSARY)
I
EXISTING
WELL
FROM
DISTRIBUTION BOX WITH \
FLOW REGULATORS ON
OUTLETS.
JOB NO. 10559
u
1'
0
r
SCALE
1"=60'
........... \
PROPOSED
B \
BEDROOM
RESIDENCE /
CLEANOUTS /
NOTE:
CLEANOUTS ARE
BE PLACED AT 100
FOOTINTERVALS
ALONG DOSING PVC
LINE.
2000 -GALLON TWO-COMPARTMENT
PRECAST CONCRETE SEPTIC TANK WITH
q� AN EFFLUENT FILTER ON THE OUTLET
2000 -GALLON TWO-COMPARTMENT
PRECAST CONCRETE SEPTIC TANK
/WITH A DOSING SIPHON IN THE
SECOND COMPARTMENT
NOTE:
,-----'IRRIGATION DITCH
IS LINED WITHIN /
188' OF DRAIN /
FIELD /'
I
2387 SF OF INFILTRATIVE AREA /
IN 6 GRAVELLESS BEDS. BEDS /
"A" MUST HAVE 2 ROWS OF II
CHAMBERS, BEDS "B" MUST HAVE
A 3 ROWS OF 11 CHAMBERS. /
B /
A j
AA /
/
/
/
/
/ 1/24/01
OWS AS -BUILT DRAWING / FIGURE 1
/
9
•
Odb+-
0
0
' `N'.
�y.00
0
CHURCH & Assoc
ENGINEERS & GEOLOGISTS
January 11, 2001
Robert Trown and Associates, ATTN: Jeffery Hancox
P.O. Box 6820
Snowmass Village, Colorado 81615
0
Inc.
�-
I /01
I �
i
Subject: Subsurface Investigation and OWS Design, Proposed Stievelman Residence
Lot 4, Aspen Valley Downs
Pitkin County, Colorado
Job No. 10559
Gentlemen:
As requested, we are providing this OWS design for the subject site. The subsurface investigation and
percolation test was performed on November 8, 2000. All previous designs and/or revisions should be
discarded to avoid confusion.
SITE CONDITIONS - The site is a 20 -acre parcel with a 2 -acre building envelope. The lot has a moderate
cover of grasses with random shrubs and small trees. The proposed field area has a 3-5% slope to the
southwest. The proposed structures will be served by an onsite well located 238+ feet from the proposed
drain field. An irrigation ditch is located north of the proposed field area. The irrigation ditch will need to be
lined if the required setback distance of 188 feet cannot be met. If a pond is proposed within 188 feet of the
drain field it must be lined appropriately.
PROPOSED CONSTRUCTION - A six -bedroom residence having greater than 6000 square feet (SF) is
proposed at the location presented on Figure 1. We are sizing the OWS based on six bedrooms and 1560
Gallons Per Day (GPD) using Aspen/Pitkin Environmental Health Department (APEHD) loading of 130
gallons per day per person. The average daily sewage loading is 1560 GPD and the design loading with a
peaking factor of 1.75 is 2730 GPD. The loading includes washing machines and garbage grinders.
SUBSURFACE CONDITIONS - Subsurface conditions were investigated by excavating one profile pit
and four percolation holes in the proposed field area. Subsurface materials consisted of sandy clay with
sparse roots to four feet, underlain by clayey sand with scattered rock fragments to the maximum depth
explored of 10 feet. No bedrock or ground water was encountered. Percolation tests indicate rates of 13 to
80 minutes per inch (MPI). The average percolation rate is 38 MPI.
RECOMMENDATIONS - Two septic tanks, a dosing siphon, and six chamber -beds must be installed at
the locations presented on Figure 1. The OWS design is based on an average sewage load of 1560 GPD
and a percolation rate of 38 MPI. The installation must include a 2000 -gallon two-compartment, precast
concrete septic tank with an effluent filter on the outlet, to be followed by a 2000 -gallon two-compartment,
precast concrete septic tank with a dosing siphon in the second chamber. A 250 -gallon dose is required. Six
chamber -beds, four beds with two rows of 11 and two beds with three rows 11 chambers, must be installed,
as indicated on Figures 1 and 2. A distribution box with flow regulators should be used to distribute effluent
efficiently throughout the beds. The distribution box must remain accessible after installation so that the
DENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 80032
303.463.9317 Fax: 303.463.9321
()/00 S
CASTLE ROCK 303.660.4358
EVERGREEN 303.816.1455
LOVELAND 970.663.2124
• Subs c Investigation and OWS Design
Job No. 10559
Page 2
flow regulators may be monitored and adjusted as needed. If access cannot be maintained, a flow splitter
basin with flow regulators must be installed in place of the distribution box. The distribution box must have
a minimum of seven outlets to be able to effectively distribute a 250 -gallon dose.
Vehicle movement over the drain field bed area during construction should be kept at a minimum to
prevent compaction of the receiving soils. The bottom of the beds should be scarified with a pick,
shovel, or backhoe bucket teeth prior to the addition of dispersal gravel or chambers.
The surface of the field should be seeded after installation of the beds. A native seed mix should be placed.
These mixes do not require irrigation and develop a growth 10 to 15 inches high. No automatic sprinkler
system should be installed over the fields.
OPERATION AND MAINTENANCE - The owner must realize an OWS is different from public sewer
service. The owner must be aware of and assume responsibility for maintenance. In the absence of a
monitoring program, the septic tank should be pumped every 2 years. Effluent filter and screened vaults, as
applicable, are to be cleaned during pumping. There are daily considerations such as not putting plastic or
other nonbiodegradable materials into the septic system. Garbage disposal use should be minimized.
The backwash of a water softener may be harmful to the OWS. A separate drywell should be constructed
for the backwash waste, if a softener is installed. Chemically treated water from a swimming pool or spas
should not be introduced to the OWS.
LIMITATIONS - A contractor experienced in OWS installation should install the OWS. Our investiga-
tion, layout, design and recommendations are based on data submitted. If subsurface conditions consider-
ably different from those described in this report are encountered, we should be notified to evaluate the
effect on the proposed OWS. If the health department makes modifications to this design, we should be
contacted to evaluate the impact on the performance of the OWS. The county and our firth must be
contacted upon completion of the OWS
All construction is to be in accordance with the ISDS regulations. Pipe type and size, burial requirements,
septic tank construction, and other specifications, which are not depicted in our report, are to conform to
the requirements of the ISDS regulations. The installer of the system is to have demonstrated knowledge of
the APEHD ISDS regulations and requirements and install the OWS accordingly. The county and our firm
must be notified upon the completion of the OWS
If there are questions or if we can be of further service, please call.
I
EOC/trp/erb
2 copies sent
copy to Dakota Development Group, Attn: Lee, 309A Airport Business Center, Aspen, CO, 81611
uV
LOT 4, ASPEN VALLEY DOWNS /
PITKIN COUNTY, COLORADO /
bUALL
1"=60'
i / \
i
.......... \
/ r PROPOSEDpoopolm \
/ \
a / BEDROOM
RESIDENCE /
ENCASE WATER LINE
WITHIN 10 FEET OF PROPOSED
DRAIN FIELDS WITH SCH 40
PVC PIPE 2 INCHES GREATER
IN DIAMETER THAN WATER LIP
WATER TIGHT CONNECTIONS
(IF NECESSARY)
N
EXISTING
WELL �,
AND
SETBACK
FROM WELL
DISTRIBUTION BOX WITH \
FLOW REGULATORS ON
OUTLETS.
' ....
m
0
I
i CLEANOUTS /
y. /
b:
OTE:
/CLEANOUTS TO BE
PLACED AT 100
FOOT INTERVALS
ALONG DOSING PVC
LINE.
FA
NOTE:
IRRIGATION DITCH
MUST BE LINED
WITHIN 188' OF
DRAIN FIELD
2000 -GALLON TWO-COMPARTMENT
PRECAST CONCRETE SEPTIC TANK WITH
AN EFFLUENT FILTER ON THE OUTLET
•
2000 -GALLON TWO-COMPARTMENT
PRECAST CONCRETE SEPTIC TANK •
WITH A DOSING SIPHON IN THE
SECOND COMPARTMENT
2387 SF OF INFILTRATIVE AREA /
IN 6 GRAVELLESS BEDS. BEDS /
'A' MUST HAVE 2 ROWS OF II /
CHAMBERS, BEDS "B" MUST HAVE
3 ROWS OF II CHAMBERS. /
/
/
/
/
/
/
/ 1/11/01
JOB NO. 10559 SITE PLAN AND LOCATION OF / FIGURE 1
PROPOSED OWS /
l
FA
NOTE:
IRRIGATION DITCH
MUST BE LINED
WITHIN 188' OF
DRAIN FIELD
2000 -GALLON TWO-COMPARTMENT
PRECAST CONCRETE SEPTIC TANK WITH
AN EFFLUENT FILTER ON THE OUTLET
•
2000 -GALLON TWO-COMPARTMENT
PRECAST CONCRETE SEPTIC TANK •
WITH A DOSING SIPHON IN THE
SECOND COMPARTMENT
2387 SF OF INFILTRATIVE AREA /
IN 6 GRAVELLESS BEDS. BEDS /
'A' MUST HAVE 2 ROWS OF II /
CHAMBERS, BEDS "B" MUST HAVE
3 ROWS OF II CHAMBERS. /
/
/
/
/
/
/
/ 1/11/01
JOB NO. 10559 SITE PLAN AND LOCATION OF / FIGURE 1
PROPOSED OWS /
0
TYPICAL PLAN VIEW - N.T.S.
BED TYPE "A"
(4 EACH) -
BED TYPE "B"
(2 EACH)
4" SDR 35 PVC
OBSERVATION/VENT PIPE
TYPICAL CROSS-SECTION - N.T.S.
4" SDR 35 PVC
BSERVATION/VENT PIPE
W TH CAP
3.5' MAX
1.5' MIN.
MIN
EXTENT OF EXCAVA
CALCULATIONS AND SPECIFICATIONS
DESIGN CRITERIA
MAIN RESIDENCE = 6 BEDROOMS, >6000 SF
LOADING = 130 GAL/DAY/PERSON
AVERAGE LOADING = 1560 GPD
PERCOLATION RATE = 38 MPI
AREA = (1.75 X q XRT)/5
AREA = 3366 SF
REDUCTION FOR USE OF CHAMBERS - 30%
TOTAL AREA = 2356 SF
GRAVELLESS CHAMBER
3' BY 6.25'
75'
�4" SDR 35 PERFORATED
PVC PIPE PLACED ON GROUND SURFACE ACCORDING TO
MANUFACTURER SPECIFICATIONS
(PIPE INSTALLED LEVEL)
TOTAL - SIX BEDS
4" SDR 35 PERFORATED
PVC PIPE PLACED ON GROUND
SURFACE ACCORDING TO
MANUFACTURER SPECIFICATIONS
SLOPE FOR D
RgINAGE
GRAVELLESS CHAMBER
3' BY 6.25'
BED SPECIFICATIONS
NUMBER OF BEDS = 6
LENGTH OF EACH BED = 68.75 FEET, 11 CHAMBERS
WIDTH OF BEDS "A" = 6 FEET, 2 CHAMBERS
WIDTH OF BEDS "B" = 9 FEET, 3 CHAMBERS
TOTAL NUMBER OF CHAMBERS = 154 CHAMBERS
TOTAL AREA = 2387 SF
DRAIN FIELD DETAILS
6
EFFLUENT INLET
(1/8" PER FOOT DROP)
LEVEL MANIFOLD
TRIBUTION BOX
V 7 OUTLETS)
4" SDR 35
SOLID PVC PIPE
(SCHEDULE 40
UNDER DRIVE; 1/8"
PER FOOT DROP)
EFFLUENT LINES TO ADDITIONAL BEDS
TYPICAL DISTRIBUTION BOX - N.T.S.
PLAN 3 APPROX.
VIEW r OUTLETS
ROX. INLET
CONCRETE DISTRIBUTION
-BOX OR EQUIVALENT
BAFFLE OUTLETS �4" SCHEDULE 35
PVC PIPE
rINLET
INLET OUTLET
VIEW VIEW
■ MINIMUM OF SEVEN OUTLET BOX REQUIRED
TREATMENT UNIT SPECIFICATIONS
MINIMUM TOTAL CAPACITY - 1.75 X q X (30 HOURS/24 HOURS) _
3412.5 GALLONS
RECOMMENDATION - ONE 2000 -GALLON TWO-COMPARTMENT PRECAST
CONCRETE SEPTIC TANK WITH AN EFFLUENT FILTER ON THE OUTLET
FOLLOWED BY ONE 2000 -GALLON TWO-COMPARTMENT PRECAST
CONCRETE SEPTIC TANK WITH A DOSING SIPHON IN THE SECOND
COMPARTMENT
"T08"
1.5' A
PROX.
-OUTLET
1' AP
ROX.
INLET OUTLET
VIEW VIEW
■ MINIMUM OF SEVEN OUTLET BOX REQUIRED
TREATMENT UNIT SPECIFICATIONS
MINIMUM TOTAL CAPACITY - 1.75 X q X (30 HOURS/24 HOURS) _
3412.5 GALLONS
RECOMMENDATION - ONE 2000 -GALLON TWO-COMPARTMENT PRECAST
CONCRETE SEPTIC TANK WITH AN EFFLUENT FILTER ON THE OUTLET
FOLLOWED BY ONE 2000 -GALLON TWO-COMPARTMENT PRECAST
CONCRETE SEPTIC TANK WITH A DOSING SIPHON IN THE SECOND
COMPARTMENT
y^
CHURCH & ASSOCIATES, INC.
Dosing Siphon System
2WO-GALLON TWO-COMPARTMENT PRECAST CONCRETE SEPr1C TANK
Inlet
Slope Ground
Away From Riser
Cord Grip
To Dose
Counter
Drowdown
Dose Courtier Float
Dosing Siphon/
Orenco or Equivalent
Disclosure: The owners of Church k Associates, Inc. are also own S.C.G. Enterprises, Inc.
which distribute Orenco Systems Inc. Products.
Patent # 4,439,323
® 1997, Orenco Systems, Inc.
JOB NO. 10559
Fiberglass Gosketed Lid with
Stainless Steel Bolts
PVC Riser with Grommet
(bond to tank adapter with
recommended adhesive)
1' Vent Piping
Tank Adapter
(cast or bolted)
Discharge Fittings
—Effluent Discharge
(3' dia. transport line required)
2' Flexible Hose Assembly
with Quick Disconnect
0118
Orenoo Systems®
lr=rporaimf
1/11/01
FIGURE 3
Profile:
TABLE 1 - PERCOLATION TEST RESU•S
Lot 4, Aspen Valley Downs
Pitkin County, Colorado
feet description
DATE OF TEST: 11-08-00
0'-4- lay, sandy, silty, stiff, moist, red, roots
4' - 10' Sand, clayey, very stiff, moist, red, rock fragments
NO GROUND WATER WAS ENCOUNTERED WITHIN THE EXCAVATION
1 52" 20
4.50
7.50
AVG.
DEPTH TIME
DEPTH
DEPTH INTERVAL
HOLE
HOLE
6
CHANGE,
6.00
OF HOLE, INTERVAL
START,
END, PERC
PERC.
NUMBER
5.25
(INCHES)
11
(INCHES) (MINUTES)
(INCHES)
(INCHES) RATE (MPI)
RATE,
13 13
IMPII
1 52" 20
4.50
7.50
3.00
7
20
2.75
6.00
3.25
6
20
6.00
8.00
2.00
10
20
3.50
5.25
1.75
11
20
5.25
6.75
1.50
13 13
3 54" 20
3.00
4.75
1.75
11
20
4.75
5.75
1.00
20
20
5.75
6.75
1.00
20
20
2.25
3.50
1.25
16
20
3.50
450
1.00
20 20
NUMBER OF HOLES: 4
AVG PERCOLATION RATE (MPI): 38
Job No. 10559
Profile:
TAVE 1 CONT - PERCOLATION TESTRESULTS
Lot 4, Aspen Valley Downs
Pitkin County, Colorado
feet description
DATE OF TEST: 11-08-00
0' - 4' lay, sandy, silty, stiff, moist, red, roots
4' - 10' Sand, clayey, very stiff, moist, red, rock fragments
NO GROUND WATER WAS ENCOUNTERED WITHIN THE EXCAVATION
AVG
HOLE DEPTH TIME DEPTH DEPTH CHANGE, INTERVAL HOLE
NUMBER OF HOLE, INTERVAL START, END, (INCHES) PERC PERC.
(INCHES) (MINUTES) (INCHES) (INCHES) RATE (MPI) RATE,
(MPII
4
45"
20 3.00
4.75
1.75
11
20 3.25
4.25
1.00
20
20 4.25
5.50
1.25
16
20 3.50
4.75
1.25
16
20 4.75
5.25
0.50
40
40
NUMBER OF HOLES: 4
AVG PERCOLATION RATE (MPI): 38
Job No. 10559
0 0 04
N
O"
N
h
m
�3
i
•
Elm
♦
9 0 0 0
01/12/99 TUE 08:48 FAX 1 9705 5938
SCHMUESER GORDON MEjo
1
o+a.rnrs
Sa+,oves
GM
Glenwood Springs Office
FAX:
PROJECT:
SCHMUESER GORDON MEYER, INC.
118 WEST 6TH STREET, SUITE 200
GLENWOOD SPRINGS CO 81601
(970) 945-1004
(970) 945-5948
As--PURu'gy T%WNS
PROJECT NO: I 7(
'
TO:JE�F +'Oct'
-t
Kobc�LT I flaWtJ �1
I I Original mailed.
COMM
Aspen Office: (970) 925-6727
FAX: (970) 925-4157
DATE: J a N I Z Clg
FAX: C1 Z 3 - Z Stq
CONpfDEN AMITY NOTICE
Original not mailed.
This facsimile transmission (and/or documents accompanying it) may contain confidential information belougiag to the
sender which is Protected by the engineer/(tient privilege, The information is intended only for the use of the individual
or entity named above, If you are not the intended recipient, you are hereby notified that any disclosure, copying,
distribution, or the taking of any action in reliance on the contents of tb[s information is strictly prohibited. If you have
received this transmission in error, please immediately notify to by telephone to arrange for return of the documents.
Thank you.
0 001
Total pages (including this page): Please call if this amount of pages was not received.
01/12/99 TUE 08:48 FAX 1 97045 5948
C)(S
WATER SYSTEM
SCHMUESER GORDON MEd
ASPEN VALLEY DOWNS
Aspen Valley Down is served by three water systems. Each system is composed of a
well and a holding tank. From the holding tank, water will flow to a pittess well for each
individual lot. Each lot will pump water for the home, from the pittess well to their individual
on-site water facilities, This water will be metered at the pitless well. Two-inch waterlines
serve each building envelope. Each holding tank has three floats in it to operate the system well
pump; Float 1 - high water; float 2 - operating water level; float 3 - low water. A flashing
red light will activate at the well site when the low water float is activated. Low water will
allow an average day's use of 350 gallons per day for each house as a reserve.
The common part of each water system is the well, well pump, tank and floats. The
individual part of each water system is the pitless well and pump, water meter and waterline to
residence. The homeowner is responsible for all improvements inside the building envelope.
Itis our opinion each house will need at least one "in-house" pressure tank, Each house is to
have a sprinkler system. A private fire cistern will be supplied by the common water system.
The size of this private fire cistern and pump is dependent on house size and sprinkler system
design. The water system has been designed to accommodate 5000 square feet of landscape
irrigation per lot.
Lots 1,2 & 3 Water System
This water system is located on Lot 1. Well 4 serves this water system and
produces more than 27 gallons per minute. A 6000 gallon tank is buried near the well.
Lot 4
Well 5 serves this lot. Only the well exists, as it is an individual well for a single
lot. Total well production is 11.6 gallons per minute.
GORDON MEYER, INC.
1
Z002
01712/99 TUE 08:49 FAX 1 97it5 5948
SCHMUESER GORDON MA
Lots 5 & 10 Water Sygern
This water system is located on common open space below Lot 7, Well 8 serves
this water system and produces more than 34 gallons per minute. A 4000 gallon tank
is buried near the well.
Lots 6. 7, 8 & 9 Water System
This water system is located on Lot 8, Well 1 serves this water system and
produces more than 30 gallons per minute. A 6000 gallon took is buried near the well.
Attachments:
Well legal description, well driller's report, pump test report, State drinldng water test results.
RT:714619
SCHMUESER GORDON MEYER,
16003
01/12/99 TUE 08:49 FAX 1 9705 5948
(303)925.6727
FAX(303)925.4157
Well #5 DescriDtion
SCHMUESER GORDON Me
Z 004
is avpe.w EYM
P.O. Box 2155
..,.� Aspen, CO 81612
JOD #7146
August 11, 1992
A well situate in Section 4, Township 9 South, Range 85 West of the
6th Principal Meridian, Pitkin County, Colorado being more
particularly described as follows:
Said well lying 726.73 feet north of the southerly line of said
Section 4 and 2868.93 feet east of the westerly line of said
Section 4 and whence the Witness Corner to the southwest corner of
said Section 4 bears N 89-58-09 W 2869.53 feet.
(Lot 4)
1001 Grand Ave., Sufte 2E • Glenwood Springs, Colorado • (303) 945-1004
01/12/99
TUE 08:49 FAX 1 970 945 5948 SCIURRESER GORDON" 2 005
WELL COMPLE1WN AND TEST REPORT
rOR OFFICE USE ONLY
STATE -OF COLORADO, OFFICE OF THE STATE ENGINEER
k
WELL PERMIT NUMBER MH-1e93Ds
OWNER'S NAME(S) Micheal Underwood Aspen Valley Rn
MallingAddress P. 0. Box 250
City. St Zip Voody Lreek. Co. 81256
Phone 303 92S-2017
APPROVAL# OWS31 al1W
WELL LOCATION AS DRILLED _ SV 1/4 SE 1/4 Sec. 4 Twp. 95 Range 859
DISTANCE FROM SEC. LINES:
Ft From Sec. Line. And Ft. From Sea Line_ Or
SUBDIVISION: LOT BLOCK FILING (UNII)
STREETADDRESS AT WELL LOCATION:
4.1
GROUND SURFACE ELEVATION ft. DRILLING METHOD: Air Rotary
DATE COMPLETED 05,'11/92 TOTAL DEPTH 400 ft. COMPLETED DEPTH 400 ft.
.i. GEOLOGIC LOG:
In
own TYPO or H"M (Size. calor. T_me and water uaatedl _
000-018 To it
018-400 No San la Returns Probably State
_ 9.0 D . 0 3 0
6.5 30 400
-Bridcre Formation
7. PLAIN CASING
OD(in) Kind Wall Size From (ft) To (ft)
I
0.2401 0.0 1 30
300
_PERF. $1CLG.:
5; 5 PVC 0.250 300 400
WATER LOCATED : 300+
S. Filter Pack
Material
9. Packer Placement
Type
Size
Depth
j
Interval
_-..,,!ARKS'#5
10. GROUTING RECORD
Malaria! Amour Deruhy Inlsrval Plan l
cement 3 sks 16 al/s 0-30 ilred
riIINFECTION : Type HTH Amt Used 4 oz.
6 % i I. TEST DATA : [ ) Check Box If Test Data Is Submitted On Supplemental Form.
`TI!vr3 METHOD Air coepreasar
WaTIC Level: 1y1.1 n. Uate/IlmeMeasurea US/14/92 rroouction Hate 11 gpm
Pumping Level: Total R Datefrime Measured 05/14/92 Test Length (hrs) 2
Remarks :
I rvtw read ew erarernenlB made and Wrew Irp wntenk tlweol. aM Ihat that era hue le mt-Yno.Mdge FY9uent ro Sewion 2L -*t Oe 11 eqa Cas. 41e meluy of telco ctalananis twain
rLne111U166 perkayN trw esrmo dO7w arW b Dunenanla a9 8 dea91 msdemearror.)
CONTRACTOR: Shelton Drilling Co. Phone. 303-927-4182 Lir-No. 1095
Mailin Address : PO Box 1059 Basalt Co. 816
Nemo / T11e (Please Type or PnM
Vayne Shelton / Owner
sign
pare
05/26/92
01/12/99 TUE 08:50 FAX 1 9705 5948
SCHMUESER GORDON MEJJ
SAMUELSON PUMP CO.
P.O. BOX 297
GLENWOOD SPRINGS
COLORADO 81602
Aspen Valley Ranch
9 Mike Underwood
P.O. Box 189
Woodycreek, Co. 81656
E
30.
e
R.E. Well N5
Atten: Mike
WATER SYSTEMS
SALES, SERVICE 6 INSTALLATION
945-6309
May 28, 1992
On May 13 thur 14 a well test was conducted on a new well
on the Aspen Valley Ranch. The following information was
obtained;
Well Depth ------------------400'-0"
Casing size top ----------- 7"(steel)
Standing water level --------190'-5"
Total test time -------------24 hrs.
Max. drawdown to pump intake
Total production is 11.6 gpm,
Hardness 93 grains/gal.
Iron 1.9 mg/l
pH 6.7
TDS 1140
This test was conducted with a 3 hp. Goulds submersible
Model 25EL. If you have any questions please call me Raun
Samuelson at 945-6309.
Sincerely;
Raun Samuelson
a 006
01/12/99 TUE 08:50 FAX 1 9705 5948
JOHN C.
GRANO JONC1
d39 NORTH AVENUE
SCMaTESER GORDON ME7MR.
KEPHART & CO.
ION I-HORMORE
ANALYTICAL REPORT
Received tium: Samuelson Pump Co.
Glenwood Springs, CO
GRAND JUNCTION, COLORADO 91301
2007
none
2336
Water
Customer No. _. _ ._
Labontmy No.
Snnpte
6/15/92
7/13/92
Data Received
Date
Reported
Lab number
2336
Limits for
DrinkingSuggested
ggested
Sample ID
Aspen Valley
by Colo.
Dept. Health
Downs Well
#5
Arsenic(As)
0.000
mg/l
0.05
mg/1
Barium(Ba)
0.25
mg/l
1.0
mg/l
Cadmium(Cd)
0.0001
mg/1
0.01
mg/l
Chromium(Cr)
0.000
mg/1
0.05
mg/l
Fluoride(F)
1.06
mg/l
4
mg/1
Liead(Pb)
0.000
mg/1
0.05
mg/1
Mercury(Hg)
0.00000
mg/l
0.002
mg/l
Nitrate(N)
0.047
mg/1
10.0
mg/1
Selenium(Se)
0.003
mg/1
0.01
mg/1
Silver(Ag)
0.0000
mg/1
0.05
mg/l
Color(Co/Pt unit)
0
none
PH
7.25
none
Conductivity@25 deg. C
2500
umbos/cm
none
Sodium(Na)
9
mg/l
20
mg/l
Calcium(Ca)
2B7
mg/1
none
Magnesium(Mg)
117
mg/1
125
mg/l
Potassium(K)
7.4
mg/l
none
Chloride(C1)
13
mg/l
250
mg/1
Sulfate(SO4)
900
mg/l
250
mg/l
Phenol. Alkalinity(CaCO3)
0
mg/l
none
Total Alkalinity(CaCO3)
350
mg/1
none
Bicarbonate(HCO3)
424
mg/l
none
Carbonate(CO3)
0
mg/l
none
Dissolved Solids
1760
mg/1
500
mg/l
Hardness (CaCO3)
1200
mg/1
200
mg/l
Turbidity(NTU)
11
1
Boron(B)
0.073
mg/l
none
Copper(Cu)
0.007
mg/1
1.0
mg/1
Iron(Fe)
1.56
mg/1
0.3
mg/l
Manganese(Mn)
0.010
mg/1
0.05
mg/1
Molybdenum(Mo)
0.001
mg/1
none
Ammonia(N)
0.100
mg/l
none
Phosphate(P)
0.00
mg/l
none
Zinc(Zn)
0.043
mg/1
5.0
mg/1
Lab Dir.: Brian S. Bauer
a;
O
k
r
Y
OLD 066 CH 9040 -PEPS �1 -- •� •� . v
Vbr. ii
HATCHM AREA
lS ACRICUL TURAL
EASEMENT
LOT 10
I.I .
17—�04wfq
t'�`
L 0 T 4
SAs"� 17.684 Acs
.+—
/
kd�oh16 + \ /s F I
ti \
BUILDIMQ ENVELOPE \
2.000 Ams +/-
+see set
` I
/ \ \ArCO obi
20' WELL \+
EASEMENT /
9
SAL 1 TION DITCH
rt + I
L OR/yEIYAY AS
LOT 2
?0' DRI✓WAV 1 BU T.
� � 1
it
I �
a t
� 1
/41nd5
i7ErOW AMMXXE I
mm. WvAyaf M AT-
a� 6t71e7AEWr SSSY++A1�tl77MNNpiMMV
WZ � Axry
/
/
/
/
LOT 3
sbAw
doarr+ftV a C*Awo* pelt Mm mmW nwnnww o
any 4WW a<r w. #&Wd Won OW h/vvr s.
Aotr so NO = Z give P"
fume" 'mq4 ,�"two or�"WAOSW Mwow V 0a *4 �^wV
AWN AV Awe *,/ Abff offftftwow" AW&M
S'URffr0RS
t.i
SMWIP,SA'R
0OR00Ar AfFTFR
\N9• I
,Srf Afcr1F'SF,R CORP01Y A ,rFR INC.
!16 i/. 6th Stmet; Suite 200
G�MWOOd Springs, Colorado B160l
('970) 9445-10044 /FA,f'� 9445-594'8
Aspen, Colorado ('970) 92'5-67,29'
LOT I
IjfPROdTlE'�l EYVF SlIRVEF
&RAPHIC SCALE
w +w On
(arm)
I mon - soo rt
Surveyor's CertrYicate.-
1, Kenneth R. Mon, beit? a Registered Land Surveyor in
the State of Cokyado, d hereby cerdNjr that this
#rrprawment swvey was ?made under my supervision and is true
and correct to the best N my b&W and knonledge. l
further certify that the *Povernents on the above described
porn* on this dote, 12:Aug. 1997, except utility connections
are entirety withn the dwmob►ies of the pare/, except as
shown, that there aro r� enerotwhments goon the deeenbed
premises by improrernats on any odfi *ft premises except oar
indicated, and that the is no qAoarMnt evidence_ or of
�•pedwe4�nt
except as noted r
Kenneth
DESCRIP77ON
LOT 4, ASPEN VALLEY M,MNS StAMWSYOV P.
STAT£ OF COLORADOaa>ord' to the pbt d
in Plot Book 28 at Paps 7-94,
Legend and Notes:
- • indicates to" No 3 rebor and plastic cap LS 15710,
- O indAmi4w setom wnwnt 15 rvbor and Yes ow Plastic
Cap (YPc), LA 15710
Beevdngs are found manutnents as shown.
rhis survey claw nd reproeent a title search by this
surveyw to detenwmU ownerahr'p or to discover
easements or otherom n Brom a of record. All
information pertak* to ow~st*, easements or other
encumbrances of rt•ard has been token from a title
insurance oo m*&?W.t bwved by MA -in County Tbe, Inc.
dated 2 Judy 1997 ub. ACT 12077.
- /his property is st*vct to apparent easements for
existing utilities and imd9ation ditches.
Fences are shown bacon for infor►»otion only and do not
necessorilly represeW limits of ownership.
14, 1992
✓ob No. 7f4W
Orvwn by: APF
Dots. A!/C W, d
1 Apar. M" AT 1
1
OF