24(-/7 -313 Ol 61Z
WASPEN*PITKIN •
ENVIFIONMENTAL HEALTH OEPARTMENT
APPLICATION FOR AN INDIVIDUAL SEWAGE DISPOSAL•PERMIT
Name of
OWNER( L�
���
PHONE-3�0
1 4 .
Address
of OWNER �. O P, c) -/,-(o
IC1�
Li y �
. SNDW MASS
V I LL, � • � } b lS
Name of
APPLICANT 1�1� 1 (�
LPn-ILS-
PHONE
1
PERMIT TO BE, ( )Picked Up
Rallied to:
ownar ( )Applicant
TYPE OF PERMIT) ( )New Installation ( )Repair
( Irmergency Use ( )Alteration NOT des to faller is
LOCATION OF PROPOSED SYSTEMS
Legal Description
Lot ' Block
TYPE -OF STRUCTURE: X/) Single Family Welling ( )Others /
so. of bedrooms Z+ No. of Lofts No. of Garbage Disposals
No. of Autoratic Clothes Washers -
6A-yeWay RtQ
Do you plan any further additions to the
residence? ( )YES ( )NO
No. of Automatic Dishwashers
VATER SUPPLY, ( )Private Well, Depth or�)Public, Name Of Syst4H16AW/rJ JV L;,A/?uWW% 4-4.11594
( )Spring
( )Stream or Creek -
TYPES OF INDIVIDUAL SLWACE DISPOSAL SYSTEM PROPOSED, -
(.)Septic Tank/Absorption Field ( )Aeration Plant/Absorption Field ( )Composting Toilet ( )Incineration Toiilee�t� ( )Mound
( )R¢eyeling, potable use ( )Recycling, other use ( )Vault Privy 't�)Other,S� /�/n ^•S�i ii C/�7E.•�
The initial site inspection must be arranged with the Aspen/Pitkin Environmental Health Department (925-2010. 6,10-9,10 a.m.)
before a permit can be issued. The individual sewage disposal permit must be Issued before a building permit can be obtained.
FINAL INSPECTION APPROVAL MUST BE GIVEN BY THE ASPEN/PITKIN ENVIRONMENTAL HEALTH DEPARTMENT PRIOR TO BACKFILLING ANY PORTION
OF THE SYSTEM.
Application for an individual sewage disposal permit is hereby submitted. The undersigned a ledges that the above information
is true and that (also �rmation vii invalidate the application and any subsequent POrmL�
Signature of Applicant DATE
(This application becomes. Invalid Ii montl{s from the above date.)
NOTE: PLOT PLAN must be filed with this application.
Please locate the following items by measured distances:
1. Property lines and dimensions.
2. Proposed and existing water wells on subject property and
adjacent property.
3. Domestic water service lines.
{. Proposed and existing buildings, driveways, and other
structures.
5. Streams, lakes, ponds, irrigation ditches, and other water
courses.
6. Proposed and existing individual sewage systems on subject
property.
SUBMIT A REVISED PLOT PLAN PRIOR TO CONSTRUCTION IF INSTALLATION IS TO
BE CHANGED FROM ORIGINAL PLAN.
The undersigned hereby acknowledges receipt of this individual sewage disposal perm LO app�l/ication and • perms fee Ln the amount
of S 5 Receipt Number D b O 211 Date Fee Received �— Y -/ , by,
A inistrativo Officcr
16� CQ V 130 South Galenos Street Aspen, Colorado 81611 303/920-6070
Aspen / Pitkin Environmental Health Department
Contact Log Sheet
Name: �j 4 Cr
Parcel ID#: 2W7- 3 — Q/-01,?- Address: G{� �n Snou cess SCc L /�
Date Person Spoken To Comments / Action to be Taken Initials
S2 Qrh / 5tr chr l
S i /
so hls c
i
Peak Properties
720 East Durant, Suite E7
Aspen, Colorado 81611
ATTN: Dale Potvin
RE: Lot 12, Block 1, Filing 3,
Subdivision, known and numbered
Dear Dale:
July 8, 1991
Gateway to Snowmass Mesa
as 0094 Elk Range
On July 3, 1991, this department conducted an inspection of
the referenced property, owned by Gregory C. Speer, for the purpose
of evaluating the on-site wastewater disposal and water supply
systems serving the existing dwelling. The inspection was done at
your request. This letter is our opinion of the suitability and
compliance of the systems with local and State public health codes
and accepted sanitary practices.
A review of our office records indicates that the sewage
disposal system consists of a 1250 gallon concrete septic tank and
1525 square feet of absorption trench area constructed in 1984.
A copy of the individual sewage disposal permit is enclosed. It
indicates that this department inspected and approved the
construction of this system before it was placed in operation. A
visual inspection of the premises indicates that the sewage system
is apparently functioning satisfactorily at this time. However,
we wish to emphasize that this letter is not to be interpreted as
implying any warranty regarding this sewage disposal system.
As a part of this inspection, the septic tank was pumped,
receiving the maintenance required every two years by County
regulation.
Water to this residence is supplied from a well and community
water system. Samples collected each month meet standards for
coliform bacteria established in the Colorado Primary Drinking
Water Regulations. The Colorado Department of Health performs an
annual inspection which indicated that the system is in compliance
with requirements for adequate treatment.
If you have any further questions regarding this letter or if
we may provide additional assistance, please call.
cc: +
3
Resp tfu11 sub it d,
7F_
Robert F. Nelson
Environmental Health Officer
May 9, 1975
Jim Butterfield
c/o Clay Crossland
Bos 737
Basalt, Co. 61521
- qio — SYS -01 -OIX
Be: Lot 12, Block 1, 3rd Filing, Gateway to Snowmass Subdivision
Dear Sir:
A preliminary investigation and soils test was conducted on the above --
captioned property on May 1, 19T5 for the purpose of determining the
suitability of the site for an individual sewage disposal system.
The average percolation rate was 47 minutes to the inch
and that portion of the lot where the proposed system is to
be installed was relatively level. therefore, it is the
conclusion of this L•epartment that a conventional septic task -
absorption field cats be installed in compliance with the Pitkin
bounty Indlvla,al Sewage Disposal Regulation. It is suggested
that the absorption field be located to take advantage of the
improved percolation of the gravel stratum located on the
southeastern Port"5n of Lhe lot.
Shou13youu leave any further question] concerning this matter,
_Tease call 925-4366.
RFN:sgp
t1
Sincyrt .0 e5�
o
R/b/ert F. Nelson, R.P.S.
Assistant Sanitarian
I ASPEN#PITKIN Qn
ENVIRONMENTAL HEALTH DEPARTMENT
January 21, 1991
Mr. Jim McNeil
Alpine Engineering, Inc.
P. O. Box 97
Edwards, Colorado 81632
Re: On-site Wastewater Disposal System Design for the Dance Lot
described as A 1.09 Tract of Land in Section 34, Township 8
South, Range 86 West of the 6th P. M. (Lot 12, Block 1, Filing 1
Gateway to Snowmass Mesa Subdivision)
Dear Mr. McNeil :
We have completed our review of the engineering design for
the referenced property which we received from Craig Dance on
January 14, 1991. As you are aware, under Colorado State Law
(C.R.S. 25-10-101 through 112) and the Pitkin County Regulations
on •Individual Sewage Disposal Systems, the site is considered
unsuitable for conventional sewage system designs due to the
steep slope, the shallow, fractured shale bedrock and the lack of
developed soils. Normal on-site sewage disposal techniques do
not offer an acceptable solution for the construction of a septic
system for the single-family house proposed for the property.
The engineering alternative, as you have proposed in your design
dated December 11, 1989, are generally acceptable.
Based on this design, a permit for an on-site wastewater
sewage system could be could be issued by this department.
However, we would recommend several possible design changes or
alternatives with the potential to improve the performance and
system longevity.. These techniques include the following:
1) Using a dosing chamber to intermittently and
sporadically load the sand filter.
2) Use narrower trenches to avoid deep cuts and backfilled
areas (for example to use trenches, each perhaps 55 feet in
length)
3) Utilize smaller diameter (1" to 1 1/2") Schedule 40 PVC
water pipe with perforations of 1/8 to 1/4 -inch diameter
spaced at distances of about three feet along the bottom of
the bed or in each trench. The goal is to achieve a minimum
operating head of two feet at the distal end of the
distribution lateral lines of the absorption area. We refer
you to Section 5-5 of the basic Pitkin County
specifications.
4) The substitute underlying fill material is not
specified, as by particle size distribution. We assume a
fine sand or sandy loam is to be used. Either fill will
provide an effective filter for adequate treatment of the
septic tank effluent.
5 - 130 South Galena Street Aspen, Colorado 81611 303/9e0-6070
0 0
Dance Engineered on-site Sewage System
Plan Review
January 21, 1991
Page 2
This parcel should accommodate each of these suggested
modifications in compliance with County regulations. Please let
us know what you think of these design changes, once you have had
time to consider them.
We remind you that Section 3-8.4 requires you to certify in
writing to this Department that construction and installation of
the system has been completed in accordance with the terms of the
sewage disposal permit and your design plans and specifications.
If you have further questions regarding this matter, please
call.
Since
vzlw;�
Ro ert F. Nelson
Environmental Health Officer
CO
TOPOGRAPHIC MAP OF A PORTION OF
LOT 12
BLOCK/, FIRST FILING
GATEWAY OF SNOWMASS MESA SUBDIVISION
PI TK/N COUNTY, COL ORA DO
GENERAL NOTES
1. Date of Survey: September 15, 1909
2. Eu is of EearLng: N24'00'00"E along the vast boundary of Lot 12, and the
line common to Lots 12 and 130 between monuments found.
3. All notes set forth on the map of Gateway of Snovmass Ness Subdivision,
First Filing are applicable.
4. This property is subject to applicable protective covenants.
5. Benchmark is top of pin and cap, NE corner of Lot 12, assumed elevation of \
100.00.
6. Easements that affect this property are not shown and are not a part of
this survey. Refer to an updated title commitment for any title
Information.
7. Contour interval is 2 feet.
8. NOTICE: According to Colorado law you must commence any legal action based
upon any defect In this survey within three years after you first discover
ouch defect. In no event may any action based upon any defect 1n this
survey be commenced more than tan years from the date of the certification
shown hereon.
i1T /7
I
IAINTAIN 10' SEPARAT N
ROM SEWER LINE \ \\ \
XX
PROPOSED IOO)S GR4. \
SEPTIC TANK \,\
LOT 12
SETBACK L
NOTE: .January 16, 1991, added proposed drive and proposed residence to map. The
topographic information is based upon the survey completed September 15 1989.
Any changes in topography which have occurred after September 15, 1989 are not
reflected on this map.
\`
` EXISTING
GRAVEL ROAD
—,ROAD 8 UTILITY
EASEMENT
I
2 WAY NDS
DIVERTER VALVE
OBSERVATION / VENT
PORTAL (TYP.)
I \ \
SCALE- 1" = 20'
\\\ \ \
K\ \\ 20 O 20
\ \ \ \ \ LEGEND
\ \
� —FOUND REBAR 8 CAP x33/7
TOA/`T fAi")
# 12075
ENGINEERING INC
Edwards Business Center a P.O. Box 97
e Edwards, Colorado 81632 a
303/949-4640 a 303/926-3373
SHEET
I OF I