Loading...
HomeMy WebLinkAboutpitkin.eh.246736102001 (2009Document Layout (From Most Recent to Oldest Permit) Permit Application Log Sheet/Notes & Photos Communications As -built Design Engineer Design Soil Information Water Permit & Information Second System on property Third System .etc. Floor Plans Please See Building and Land Use Approvals Files for additional information. E ONSITE WASTEWATER TREATMENT SYSTEM (OWTS) NO PERMIT REQUIRED FORM Date: Id, lea ho Owner(s) Name(s): C 2 P00 11L\-�Q'o I af) Project Name: Address of Property: ;L55-1 L% -MA Pi IJ-PA Q -00A ��/ / hr,r ray GodT�„c Building Permit Number: ')�92.7U0`� Prbu / DOSS-�-00g�• 1 Parcel ID # Iq (0 7—, blo L Description of Project: Nntil b(1A F\A . 6,+k &-W L (YnAka-1 r\ 11rUJ aaC R % c6� i Vtni cuk r tm 6vj" 6 u -f-, ( Remodel does not increase the bedroom/potential bedroom count f ISDS D501� S'eC��or (o b[vA��S. Existing OWTS is sized for this project rj a Dm in = to (Fprnnnr� 5�%lr�� Proposed buildings do not need an OWTS (i.e., garage, shed, barn, etc.) Project is not located in the area of the existing OWTS No OWTS Construction Permit is required for this project. No further review is required by Environmental Health & Natural Resources. FOOD SERVICE FACILITY This facility contains a retail food establishment. Environmental Health & Natural Resources has reviewed and approved the plans. Office Use Only: Date: 0405 Castle Creek Road, Suite 10 Aspen, Colorado 81611 Phone: (970) 920-5070 Fax: (970) 920-5077 www.aspenpitkin.com/ehnr 14 JA • Carla Ostberg From: John Blatz [jblatz@ccmaspen.comj Sent: Monday, December 21, 2009 523 PM To: Carla Ostberg Subject: RE: 2557 Lower River Road Hi Carla. We aren't doing plans for the upper level, as there is no work happening beyond cosmetics, but there are 4 bedrooms on the upper level, as shown on the original permit plans (I do not have an electronic form of those plans). As for the scope of work, essentially, we are relocating the powder room and creating a new bedroom/bath suite at the main level. Ultimately, we are doing a theater and gym at the lower level. That's it for now. The total count of bedrooms will be 6 when all is said and done. Hope that helps. Thanks, John From: Carla Ostberg [mai Ito:Carla.Ostberg@co.pitkin.co.us) Sent: Monday, December 21, 2009 4:38 PM To: John Blatz Subject: RE: 2557 Lower River Road Can you send the entire floor plan? I just need to count TOTAL bedrooms. Also, can you give a quick summary of the project/remodel? It doesn't have to be detailed. Carla Ostberg, MPH, REHS Environmental Health Program Supervisor Pitkin County Environmental Health 970-920-5438 From: John Blatz [mailto:jblatz@ccmaspen.com] Sent: Monday, December 21, 2009 3:08 PM To: Carla Ostberg Subject: 2557 Lower River Road Hi Carla, Attached are the documents for the building permit that we discussed the other day. Parcel ID is 2467 3610 2001. Give me a call if you have any questions, or let me know if it's approved so I can pick up the permit. Thanks! John CELEARWATER COIVo7RIUCTIOIV John F. Blatz, President Clearwater Construction Management, Inc. PO Box 939 Carbondale, CO 81623 970.379.3709 cell 970.963.1599 fax blatz(d)ccmaspen. com Q • -___________ �- is u�mun M� rwovs 9— miv:@, uw o wunu. uw PROPOERO PARTIAL LOWER LEVEL FLOOR PLAN ,/ s r PO Box 2944 0111 FAX303-2&-2796 162 May 1, 2008 Clearwater Construction Attn: John Blatz PO Box 939 Carbondale, CO 81623 aLlb"1— 36i-- D2 -LD1 Onsite Wastewater System Evaluation, Existing Residence 422 Lower River Road Pitkin County, Colorado John, Project No. 1673 As requested, ALL SERVICE septic, LLC performed an onsite wastewater treatment system (OWTS) evaluation on December 17th 2009 for the subject property. The OWTS was permitted by Pitkin County, under permit 4109009. 'According to Pitkin County Environmental Health Department the residence has an OWS permitted for 44WAisenR and consists of twodft-gallon septic tants with a pump, and 279 °standard' gmvellm chambers.' OBSERVATIONS The existing septic tanks were inspected. The pumping compartment of the tank series was accessible and was inspected. The pump control panel is located next to the septic tanks. The pump, floats and control panel were working properly during our site visit. The septic tanks have good integrity and had a sewage level to indicate the tanks are working properly. The drain field area had several inches of snow during our inspection, although we were able to confirm vegetation conditions on top of drain field. The area of the drain fields has adequate vegetation, and the drain field areas showed no signs of surfacing effluent, and had no indication of failure. The OWTS was functioning normally at the time of our inspection. This evaluation is not a guarantee of any future drain field performance, in any way. ALL SERVICE septic, LLC evaluated the OWS, and has no further knowledge of use and/or performance, and/or any changes. Please call with questions. , Lr M Y v/ g 0 a f - Ir rmr usr yd ,r .�`q mll AIS/ �` 1 / 3s1b11 O3 3X11 3OMa35 a3lYa f r NM ffi Ol )UYO1E pC Yof �vaz3s zsl ` YAM .ir ASLN3T3WfG3Y 1r13O aid SOa In IV amm 3s ' w aO Ya NryaNna 01 030 b dOl Y 'p ��� SV 531x1 3JNll3S UWW UNI s3IVa M331LLLL39 WIVNVM1 N1111NN1 V luL M Vwm 3O sN% OJ 31va O113d xfaiV 'aLrl 1\+ ,OI �1�'-�56dOad • MV aU" xVn Igrq Mb ISM V3M w11daOS0V � lad 113OIJ1 T3I.31� -m = OKf tAiI1 �QTh9JV YM OSl SSVn .r1 MYa Xa 3l3OIDO �q 03111vBa11QiF0 OBOL IyAW\ 4 a .O 'I.Ag sV Q MVI ll ]9wD wThO 0001 g 0 a I SCHMUESER GORDON IMEYER E N G I N E E R 5 5 U R V E Y O R 5 March 21, 2007 0 GLENWOOD SPFwG5 <SFlEr, I I a W. 6T ' SURE 200 P.O. BOX 2155 GLENWOOO SPRINGS. CO 81601 ASPEN. CO a 161 2 970.945-1004 970.925.6727 Px: 970.945-5946 FX: 970.925-4157 CRESTED BIi E P.O. Box 3088 CRESiEO 8V . CO 81 224 970-349-5355 P : 970-349.5358 Carla Osterberg Pitkin County Environmental Health 0405 Castle Creek Road, Suite 10 Aspen CO 81611 Fax: 920-5077 RE: Eroncig Residence ISDS, Lot 1, Murry Subdivision Dear Carla; The purpose of this letter is to provide a Record Drawing for the ISDS application for the Eroncig Residence, Lot 1, Murry Subdivision, located on Lower River Road in Pitkin County, Colorado Following the original design, percolation rates were verified during the initial construction of the system at a design percolation rate of 30 minutes per inch. The system constructed is an absorption bed consisting of 11 rows of 25 chambers (33' x 100', 275 units). A barn is included in the design flow, however, at this point the structure has not been constructed. The system was observed during the excavation and installation of infiltrator units prior to backfill and construction conformed to the plan and subsequent letter revisions prepared for the project. The attached Record Drawing identifies the final configuration of the system. Please do not hesitate to call should you have any questions or comments regarding this submittal. Sincerely, Schmueser Gordon Meyer, li Dan Cokley, P.E. CC: Alan Styers, 923-9514 Jeff Brain, 963-2247 1:\7995\95101 W\Corresp\95101A_isds_rev.doc ' Binderl.pdf • • Page 1 of') Carla Ostberg From: Dan Cokley [DanC@sgm-inc.com] Sent: Friday, April 13, 2007 1:03 PM To: Carla Ostberg Subject: RE: Binderl.pdf - Eroncig Liner extension OK... The liner was extended to a location that is at least 102' away from the absorption bed. When I was out on site last week, the small, ponding area of the stream was approximately 110' away from the bed. It appears the liner was extended to that location. Thanks, Dan Cokley, P.E. ISSCHMUESER GORDON MEYER E N a I N E E R B B U R V E y O R S I 1 8 WEST 6TH STREET. Su1TE 200 GLENWOOD SPRINGS. CO 8 1 601 970-945-1004 / FAX: 970-945-5948 WWW.SGM-INC.COM From: Carla Ostberg [mailto:carlab@co.pitkin.co.us] Sent: Friday, April 13, 2007 12:57 PM To: Dan Cokley Subject: RE: Binderl.pdf - Eroncig Liner extension Since this is for my sign off — can you say that with a little more certainty? Carla Ostberg, REHS Environmental Health Program Supervisor Pitkin County Environmental Health and Natural Resources 970-920-5438 4/13/2007 Binderl.pdf • • From: Dan Cokley [mailto:DanC@sgm-inc.com] Sent: Tuesday, April 10, 2007 1:03 PM To: Carla Ostberg Cc: Alan Styers Subject: RE: Binderl.pdf - Eroncig Liner extension Carla The liner looks to have been extended to a location 102' away from the existing absorption bed. Thanks, Dan Cokley, P.E. ISSCHMUESER GORDON MEYER L H O I H! C R S S U R V E Y O R S I 18 WEST 6TH STREET. SUITE 200 GLENWOOD SPRINGS, CO 8 1 601 970-945-1004 / FAX: 970-945-5948 WWW . SGM-INC. COM From: Alan Styers[mailto:alan@styersconstruction.com] Sent: Tuesday, April 10, 2007 12:27 PM To: Dan Cokley Cc: Carla Ostberg Subject: Binderl.pdf Page 2 of 3 Sending pit's of the linner at the location Dan wanted to add to. We will be putting the rocks on but wanted to get a pic of the linner so you can see 4/13/2007 Carla Ostberg From: Carla Ostberg Sent: Tuesday, March 27, 2007 9:55 AM To: 'Dan Cokley' Subject: RE Eroncig Dan I think this is all coming together now. I did have an entire disc of pictures from the installation and some nates that were not in chronological order — so it's starting to make much more sense. _ Your as -built reflects a liner should be placed within 50' of the ditch. Due to the size of the field, the ditch needs to be lined within 102' of the field (this is actually reduced in accordance to your letter dated 11/25/02). I also would like confirmation from you that the pump is working properly. If you would like to provide me a letter or e-mail confirming those two items (Alan is going to send me a picture of the liner), that would be great. Before we are able to sign off on CO, we have to receive documentation from the designing engineer that the system was installed per all design criteria and is ready for use. Please let me know if you have any questions. Thanks! Carla Ostberg, REHS Environmental Health Program Supervisor Pitkin County Environmental Health and Natural Resources 970-920-5438 From: Dan Cokley [mailto:DanC@sgm-inc.com] Sent: Friday, March 23, 2007 11:06 AM To: Carla Ostberg Cc: styers@sopris.net Subject: RE: Eroncig Hi Carla Attached is the letter from HP regarding revised percolation rates. Note that the location of the perc holes are noted at the bottom of the tabulated results page. Thanks, Dan Cokley, P.E. I SCHMUESER GORDON MEYER \�J) c N O 1 N[ C R S 4 u R v C r o n s 1 1 8 WEST 6TH STREET. SUITE 200 GLENWOOD SPRINGS. CO 8 1 601 970-945-1004 7 FAX: 970-945-5948 WWW.SGM-INC. COM From: Carla Ostberg [mailto:carlab@co.pitkin.co.us] I G) 3/27/2007 • • Page 2 of 2 . Sent: Thursday, March 22, 2007 5:22 PM To: Dan Cokley Subject: Eroncig Hi Dan, I received your as -built letter and drawing today. In going through the file, I see there are several other things we are still waiting on. 1. A map from HP indicating location of soil testing from 3/05. 2. Confirmation the pump was installed and working. 3. Confirmation the irrigation ditch was lined within 102' of the field. In addition to those items, I do not have a note that we inspected the installation. My notes from March of 2005 indicated that the system was under construction at the time the new permit (#05009) was issued. You are listed as the contact for this project. Is there another person I need to touch base with to coordinate a site visit to determine if this permit can be finaled (pending submittal of information listed above)? I do have a note that Leonard Lewis from Aspen Earthmoving was involved in the project. I am happy to contact them, but it would also be helpful to contact whoever is the current contractor — Alan Styers?? Thanks, Carla Ostberg, REHS Environmental Health Program Supervisor Pitkin County Environmental Health and Natural Resources 970-920-5438 1/ 3/27/2007 Q • . Page 1 of 1 Carla Ostberg From: Carla Ostberg Sent: Thursday, March 22, 2007 5:22 PM To: 'danc@sgm-inc.com' Subject: Eroncig Hi Dan, I received your as -built letter and drawing today. In going through the file, I see there are several other things we are still waiting on. 1. A map from HP indicating location of soil testing from 3/05. � 2. Confirmation the pump was installed and working.a� �C 3. Confirmation the irrigation ditch was lined within 102' of the field :-f+ VY6 In addition to those items. I do not have a note that we inspected the installation. My notes from March of 2005 indicated that the system was under construction at the time the new permit (#05009) was issued. You are listed as the contact for this project. Is there another person I need to touch base with to coordinate a site visit to determine if this permit can be finaled (pending submittal of information listed above)? I do have a note that Leonard Lewis from Aspen Earthmoving was involved in the project. I am happy to contact them, but it would also be helpful to contact whoever is the current contractor — Alan Styers?? Thanks, Carla Ostberg, REHS Environmental Health Program Supervisor Pitkin County Environmental Health and Natural Resources 970-920-5438 3/22/2007 03/21/2005 08:46 FAX 970 945 5948 • mow SCHMUESER GORDON MEYER is E 1- G: a E E II S -i"', March 21, 2005 Carla Block Pitkin County Environmental Health 0405 Castle Creek Road, Suite 10 Aspen CO 81611 SCEMOESER GORDON NEYER RE: Eroncig Residence ISDS, Lot 1, Murry Subdivision Dear Carla; , 19 w, BTM. SUITE 2(-i0 ptcv.XaA 8/'WOB. W B 1 BOI 970'945 1994 "_ 970'945.5948 P.O. pOt 21 S$ •SPeN. Co B I B 12 9>0923872> rw_ 970 925-41 57 ®002/002 • o_ eoK JOBB CeCSIW euTR, CO 81 224 97 9.5355 , 970-349.5359 Fax: 920-5077 The purpose of this letter is to provide updated design information for the ISDS application for the Eroncig Residence, Lot 1, Murry Subdivision, located on Lower River Road in Pitkin County, Colorado. Under separate cover, updated percolation testing results completed by HP Geotech will be provided. As stated in earlier project correspondence and the original design drawings, design percolation rates were recently verified during the initial construction of the system. The leachfield location was staked and partially excavated on site. Percolation test holes were located in each corner of the proposed field. The percolation results were favorable and we will be using a design percolation rate of 30 minutes per inch. The contractor is using Infiltrator "Quick 4 Standard" chambers, the design allows for 92 s -f. per chamber. Applying a 30% reduction factor for gravelless chambers, there will be 257 units required for the bed configuration. Itis suggested that a bed consisting of 11 rows of 25 chambers be constructed (roughly 33'x 100', 275 units). Please do not hesitate to call should you have any questions or comments regarding this Submittal. Sincerely, Schmueser Gordon Meyr '-- Dan Cokley, P.E. CC Alan Styers, 923-951, Jeff Brain, 963-2247 c11995195101W1Corresp195101A_ lsds rev.doc �3 03/121/2005 08:45 FAX 970 945 5948 G0 SCMMOESER I GORDON I MEYER ENGINEERS LDURVCIORO SCHMUESER GORDON MEYER, INC. 118 West 6" Street, Suite 200 Glenwood Springs CO 81601 http•llwww sgm-int. corn SCHMIIESER GORDON MMR [001/002 Glenwood Springs Office: (970) 945-1004 FAX: (970) 945-5948 Aspen Office: (970) 925-6727 FAX: (970)925-4157 Crested Butte Office: (970) 349-5355 FAX: (970) 349-5358 Meeker Office: (970) 878.5180 FAX: (907) 878-4181 MISSION STATEMENT We exist to make our clients successful. We do this by understanding their development and infrastructure needs, and the unique environment of the valley communities where we lire. We provide responsive, appropriate engineering, surveying and consulting services to achieve our clients' goats while protecting the health safety, quality of life and mountain environment of our neighbors. Project No: To: ;Z Via. til-�c`=;fes To: To: - To To: ['(Jj Original mailed. COMMENT: , ae-ir Fax: Fax: cam,,. J 4.'=..Z C;;'T [ ] Original not mailed. CONFIDENTIALITY NOTICE This facsimile transmission (and/or documents accompanying it) may contain confidential information belonging to the sender, which is protected by the engineer/client privilege. The information is intended only for the use of the individual or entity named above. If you are not the intended recipient, you are hereby notified that any disclosure, copying, distribution, or the taking of any action in reliance on the contents of this information is strictly prohibited. If you have received this transmission in error, please immediately notify us by telephone to arrange for return of the documents. Thank you. ,............................................................ I . . . . . . . . . . . . . Total pages (including this page): L'VmmsVadorm I Ll Please call it this amount of pages was not received. PTTKIN ENVIROMENTAL HEALTH DEPARTMA ISDS DESIGN CALCULATIONS Owner's Name Parcel ID # House Size (sq. ft.) (75 gpd, 100 gpd, or 130 gpd) 130 Number of Bedrooms in Main House Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House Number of Bedrooms in Detached Caretaker unit Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit (If the caretaker unit is ATTACHED, treat as if part of main house.) Average Daily Waste Flow 1560 } zC)G = 11 (o O State Review Required? no Perc Rate _(T) Design Flow (Q) = # poten4bedrooms X 2 people/bedroom X gpd X 1.75 Q= 2730 1 30: 15(00 t 2vv = 1(DO x 1."15 Wi Minimum tank capacity 'i t gallons 3850 1 r 'rn S /J -�- �arse si-all s I Absorption Area (=Q/5 X SART perc rate) 709 X �-� A = �c,�, .� V �U' - Ifi � 1p X 54 I i sq. ft:'oi absorption area required 193 gravelless chamber units without reduction # of Perc Holes Required: 3 1 in every soil type? Spaced uniformly over proposed area? �, (� Ali 1(K4 9_8QUICK 4 ��(Of `�•.p �� / 1•� A = 1495.2826 sq.ft with 50% reductionTRENCHES sq ft 30% reduction BED I '� I graveBew chamber units with reduction »K chamber units with reduc. A = 1495.2826 sq.ft. with 50% reductionTRENCHES `1i • gravelless chamber units with reduction II iLiL 11 1 EQ36 units in TRENCHES SETBACK FROM WELL # of feet = 238.4 SETBACK FROM POND, STREAM OR IRRIGATION DITCH # of feet = 188.4 SETBACK FROM DRY GULCH # of feet = 163.4 Z5"] MAD 2093.3956 sq ft 30% reduction BED I � 5 chamber units with reduc. I (,s EQ36 units in a BED MPR -21-2005 14:40 H -P GEOTECH 0 - PWDT H.-PAWLAY\ GEOTEC4NICAL R!a►ch 21, 2005 ! Ic^a,••'"wi;h t ....... I. ill. )i.•l l\".1..' ➢tPp1111!.v v :.`, J. 150: 1 oucu: aY,- AIIII -o or. -...nr. M.- James 1. Eroncig cin Peninsula Corporation 2100 Coral Way. Suite 603 Miami, Florida 33145 Joh No. 101 830 Suhiect: Additional Percolation Testing, 2565 Lower River Road. Pilkin County. Colorado Dear Mr. Eroncig: As requested by Leonard Lewis with Aspen Earthmovers. llepwortb - Pawlak Geotechnical, Inc., performed additional percolation testing at the suhicet s'lc. We pteviously pedormed percolation testing for the proposed residence and presented our findings in a letter report dated May 30, 2002, .lob No. 101 830. Fou: percolation test holes were hand dug on March 17, 2005 at each corner of the butmm of the leach field excavation. The excavation was approximately 20 feel by 90 feet in size and fixated northeast (uphill) of the propo.wil residence which was under construction at the time of our site visit. The excavation had been cut in one level between 4% wit 5% feel below the original ground surface. The subsoils exposed in the brrnom of the excavation consisted of silty sand and clay and silty clavey sand with gravel. No free water was observed in the excavation and the soils were slightly moist to midst. The test holes were coveted overnight with rigid foam insulation to prevent freezing. The additional percolation testing was conducted on March 18, 2005, by a representative of Hepworth - Pawlak Geotechnical, Inc. The percolation test results are summarized on Table 1. The percolation test results indicate infiltration rates between 20 and 30 minutes per inch with an average of 25 minutes per inch at hole depths between 54 and 78 inches below the original ground surl'ace. Soil temperatures ranged between 36 drgrees and 37 degrees Fahrenheit at the lime of testing. Previous percolation testing perRanted in Parker 3.3.841-7119 • Colorado Springs 719-6.33-5562 • Silverrhorne 97,468-1989 IG MRP -21-2005 14:40 .Tames J. Eroncig March 21, 2005 Pag-e 2 H -P GEOTECH • P.03/04 rougidy the saunc location atthe site indicated an infiltration rate of 60 uninuws per inch at a haie depth of about 31 inches below the original ground surface. teased ori the subsurface conditions encountered and the additional percolation test results, the tested star. should be suitable for a conventional inliltmtion septic dis rnsai system Pilkin County requires a professional civil engineer to design the septic dispersal s. stem. If you have any questions or need further assistance, please call our office. Sincerely, HOWORTH - PAWLAK GEVTECHNICAL, INC. Trevor L. Knell, P.E. Reviewed by: TO atta- -- - Sults cc Schmmser Gordon Meyer — Attn: Dan Cokley Pitkin County Environmental Health — Carla Block lobN07101830 _ G99WCh MRR-21-2005 14:40 H -P GEOTECH 0 is HEPWORTH-PAWLAK GEOTECHNICAL, INC. TABLE 1 PERCOLATION TEST RESULTS HOLE DEPTH LENGTH OF MOLE NO (INCHES) • INTERVAL (MIN) P•1 72 P2 P-3 P-4 78 54 j 15 �I I ADDED WATER I f 15 ADDED WATER 15 I I ADDED WATER t5 I 1 ADDED WATER i I 1 P.04/04 Note: Percolation test holes were hand dug at each corner of the bottom of the leach field excavation and soaked on March 17, 2005. Percolation tests were conducted on March 48, 2005. The average percolation rates were based on the last three readings of each test. The test holes were covered overnight with rigid foam insulation to prevent freezing. The hole depth is measured from the closest adjacent ground surface. N JOB NO. 101 6.30 WATER _WATER DROP IN j AVERAGF: DEPTH AT DEPTH AT WATER PERCOLATION START OF I END OF j LEVEL i RATE INTERVAL i INTERVAL ! (INCHES) i (MIN .IINCHI _INCHES) (INCHES) _ .... 6.25 I 5.25 5.25 450 0.75 7.00 600 tGG Boo i 5.25 0.75 5.25 4.50 0.75 4.50 :i 75 0 7`+ 3.75_! 300 j 0.75., ,.. _ _- y 20 7.S0.-. j 6.00 _ 6.0D I 5.00 1.00 1� 5 00 400 7.00 _�I 7.00 I 6 00 �.... 1.00 I ` _ 5.00 -..i -5.25. 0.75 1 5 25 I 4.50 I 0.75 I _ 4.50 I 3.75 ^� 0. i5 3.75 ) 3.00 _ i 0.75 20__,_ 8.00 x•.7.00 1.00• 7.00 6.25 i6.25 5.50 _.. 0.75 .....I 7.50... ....._. 6.75 0.70 ._ ._ 6.75 6.25 0.50 6.25 5.75 0.50 5.75 5.25 i ..__�..__ 0.5n .. 52530 0.50 30 .. ._ - 7.00 6.25 I 0.75- G.25 550 0 75__l , 5.50 4.75 075 6.75 6.00 i 0.75 I 6.00 550 0.50 I 5.50 5.00 0.50 . - -- i 5.00 4.60- 0.5^ i 4.50 4.00 ' 0.5c 30 Note: Percolation test holes were hand dug at each corner of the bottom of the leach field excavation and soaked on March 17, 2005. Percolation tests were conducted on March 48, 2005. The average percolation rates were based on the last three readings of each test. The test holes were covered overnight with rigid foam insulation to prevent freezing. The hole depth is measured from the closest adjacent ground surface. N 0 jima@co.piddn.co.us, 02:58 PM 8/12/2004, Eroncig 2565 Lower River Rd To: jima@co.pitkin.co.us From: Nancy MacKenzie <nancym@co.pitkin.co.us> Subject: Eroncig 2565 Lower River Rd Cc: Bcc: Attached: Jim, I reviewed the new floor plans which eliminates the caretaker unit and Eny Health is okay to issue the building permit. I inted for Nancy MacKenzie <nancym@co.piddn.co.us> A2.1 A2.0