Please See Building and Land Use Approvals Files for additional information.
Permit # 02071
Type of permit Remodel
Name of Owner Roaring
�I
7
Pitkin County Environmental Health Department
Permit for an Individual Sewage Disposal System
0405 Castle Creek Road, Suite 10, Aspen, Colorado 81611
Phone 970-920-5070 / FAX 970-920-5077
Parcel ID # 2643-064-00-016
River Ranch
Street Address 158 Gerbaz
Property legal description
Size of lot
Water source
# of potential bedrooms in
Secetion 6. T9 SR 85W
acres Total square footage of the house
165
Caretaker unit Total square footage of the caretaker unit
# of potential bedrooms in caretaker unit l}
Designed for what # rooms (list) Shed with toilet and sink — SiHCl G f t pL urA
Designed by
Perc rate 17
Permit information
High Country Engineers 923 Cooper Ave GWS 81601
Profile hole depth 12 Depth to groundwater or bedrock
Minimum Septic tank capacity
750 Minimum Absorption area
n�T1rT--TiM,
185
+12
Septic permit approved per compliance with the engineer design and specifications stamped 8/28/02. Any
changes must be approved by this department and the design engineerrp for to them being made.
Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin
County ISDS regulations.
Design is for a 1,000 gallon two compartment septic tank with an effluent filter. See engineer design for specs on 8
It diameter drywell drywell.
This department does not endorse any brand of products. This permit must be kept on-site during installation.
The engineer must do a final inspection of the installation and submit an as -built letter to this department. This
department must also be called for an inspection with
/a minimum of 48 hours advanced notice.
_-- 1/e...- i inn _ M'_' Y J. _ `;
-4
Permit
Date: 5742 5 D
Plans and specifications of the pro$osed individual sewage disposal system have been reviewed and are considered
satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin
County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was
issued unless system construction has commenced or an extension has been approved in writing by the Department.
As -built drawings mustbe included with this permit before the final approval will be issued.
Installer btiL�� k, l u
Finalin>tlona L L �IOC�X
Date: z L
I�
PITKIN COUS ENVIRONMENTAL HEALTH DEAENT
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM
0405 Castle Creek Road, Suite 10, Aspen Colorado 81611
Phone 970-920-5070/Fax 970-920-5077
Name of OWNER 0, , - y_ Nz.l_
Owner's Mailing Address 6',rx.
Business Phone: Home Phone: 3 79 d
E-mail Address: ce (i 4
Primary Contact Person (all communication regarding this permit will go through this person)
Name C C .( /
-t—
Company
Contact Mailing Address
Business Phone: 01 Cell Phone: / - Fax:
E-mail Address:
r•arcei w s tavauaDie rrom assessors oruce
at 920-5160 or at www.aspen.com/assessor/)
Street address of property I D T) -
Legal Description: Lot ,Block
e,- A.
,Filing
Size of lot: acres. Type of proposed structure
( Subdivision
*�(4 Size of bldg. envelope:
Total square feet of house 16 5- # of bedrooms in house
# of offices, lofts & similar sized rooms in house
Caretaker Unit: Attached ( ) Detached ( ) Total area(sq. ft.) of caretaker unit
# of bedrooms in caretaker unit # of offices. lofts and similar size rooms of caretaker unit
Permit is for: New Home ( ) Repair due to failure ( ) Remodel/Addition Qo ) Emergency use ( )
Water: Private well (f ) Spring ( ) Stream ( ) Community/Public Water System ( )
If community system: Name of system
The fee for a ISDS application is $330 for a permit that takes 6 hours or less for the department to approve. If approval takes
longer than 6 hours, a rate of $65 per hour will be charged. The maximum fee is $1000. The basic fee of $330 is due at the time
of application. The remainder, if any, will be due in two stages: first, at the time of issuance of the ISDS permit; second, before
final approval of the ISDS permit.
Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information is true and
accurate and that I have provided true and accurate information on locations of all existing and proposed wells, contour
intervals, buildings, property lines, ditches, slopes, waterlines, springs, suction or irrigation lines, drinking water cisterns, drain
tiles, irrigation ditches, lakes, water courses, streams, floodplains, dry gulches, and existing septic systems. I hereby certify
that any such features not shown on attached site map are not present. Issuance of the permit does not imply the approval of
any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all
approvals and permits have been obtained.
is
Qd J
The Aspen/Pitkin Environmental Health Department, Pitkin County and employees of these agencies will be held harmless
should the individual sewage disposal system fail or malfunction. The permit to construct is issued on information submitted by
the applicant or his/her representatives. The owner assumes full re ty in ease of failure of the system.
Signature of applicant Date 5r4t 3
Received by Receipt # Date �� (fir►)
5'-0. 1 --) /76`x. ZpodZ
PITKIN *TY ENVIRONMENTAL HEALTH DRTMENT
IC SYSTEM APPLICATION CHEC
NOTE: SEPTIC PERMIT APPLICATIONS CANNOT BE ACCEPTED UNTIL ALL OF THE
INFORMATION BELOW IS INCLUDED.
The soils test and system design must be done by a Registered Professional Engineer. You should plan
to meet with the RPE at your site to discuss where the soils tests should be done to meet all of the
County regulations and where you want to put your house. The RPE will be your contact for issues you
want to discuss about your system's size and location. Each box should be checked to indicate the
following have been submitted before the application can be accepted.
Ltd Environmental Health has been called to look at profile hole
L om leted application form
Engineer design stamped by a RPE registered in the State of Colorado. (One set).
Design must be based on the Pitkin County ISDS Regulation, Revised 2001.
L� Site map must include locations of all existing and proposed wells within setback distances
(including on surrounding properties), contour intervals, all proposed and existing buildings,
property lines, ditches, slopes of greater than 15% in the area of the drain field, water lines,
sprinkler systems, springs, suction (irrigation) lines, drinking water cisterns, drain tiles, irrigation
di hes, lakes, ponds, water courses, streams, floodplains, floodways, dry gulches, or existing
eptic systems. This must include all such features on neighboring properties within setbacks.
Complete building floor plans. Floor plans should be 11 x17. (One set)
L� Proof of adequate water supply: (Well must be drilled before septic permit can be issued.):
For private wells, recent well driller's pump test showing gpm actually produced, well permit
showing legal supply. The minimum yield from the well or water storage shall be .07
gallons/minute/person which is 100 gallons/person/day. There must be storage or yield capable
of a 24-hour supply for domestic purposes only (not including fire protection or irrigation).
For community systems, proof there is adequate water for all houses served by the system.
Proof of adequate water quality with bacteriology test: Aspen Consolidated Sanitation District
rer
/and Snowmass Water & Sanitation District perform this test locally.
colation tests
All ISDS Permit fees are $330 to cover first six hours of processing. Hourly rate of $65 will be
charged beyond first six hours, up to $1,000. Tank only fee $110. Please make check payable
t Pitkin County Environmental Health Department.
Copy of county approval (1041 approval, subdivision approval, etc.)
You must obtain written approval from Community Development before submitting this
application if your septic system is outside the building envelope and any part of the
system is more than 30" above grade.
A WAIVER IS AVAILABLE FOR SUBMITTING A BUILDING PERMIT APPLICATION PRIOR TO
OBTAINING AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT.
Please ask the Community Development Dept. or Environmental Health Dept. for further information.
g:\eh G sd s\i sd sappli c\i sd sch ck. d oc
SEP -25-2002 11:31 H -P GEOTECH
Gecptech
August 16, 2002
Hepwok Geutechnical, Inc.
5020 Cou ood 154
Glenwood Springs, Colorado 81601
Phone: 970.9457988
Fax: 970.945.8454
hpgeo 0 h pgeotech.curn
Rich and Nancy Kinder
c/o B & H General Contractors
Attn: Steve Eichhorst
5317 County Road 154, Suite 206
Glenwood Springs, Colorado 81601 Job No. 102 441-1
Subject: Percolation Testing, Proposed Drywell Septic Disposal System, Roaring
River Ranch, Gerbaz Road, Pitkin County, Colorado.
Dear Mr. and Mrs. Kinder:
As requested, Hepworth - Pawlak Geotechnical, Inc., performed percolation testing at
the subject site. The findings of our work are presented in this report. The work was
done in accordance with our proposal for geotechnical engineering services to you,
dated August 8, 2002.
A backhoe pit was excavated on August 14, 2002 at the location shown on Fig. 1. Test
holes were hand dug at four levels in the pit and were soaked with water one day prior
to testing. The subsoils exposed in the pit consisted of about 1 foot of organic fill and 5
feet of on-site granular fill with wood fragments overlying slightly silty sandy gravel
with cobbles and boulders to the maximum pit depth of 12 feet. No free water was
encountered in the pit and the soils were typically slightly moist.
Percolation testing was conducted on August 15, 2002, by a representative of Hepworth
- Pawlak Geotechnical, Inc. The percolation test results are summarized on Table I.
The percolation test results indicate an infiltration rate of 17 and 9 minutes per inch for
tests P-1 and P-2, respectively, which were conducted in the granular fill soils. Tests
P-3 and P-4 were conducted in the natural gravels and bad an infiltration rate of 15 and
24 minutes per inch, respectively. Based on the subsurface conditions encountered and
the percolation test results, the tested soils should be suitable for a drywell septic
disposal system. We recommend that a civil engineer design the drywell septic disposal
system.
If you have any questions or need further assistance, please call our office.
Sincerely,
104=0XV1all
4
Jordy Z. Adamson Jr., E I1% D+�
90T'..lzr fa�ti
Rev. By: DEH �c �.•''V�
JZA/djb SSIONAI EN
attachments .. -
cc: High Country Engineering - Attn: Roger Neal
P. 02/05
SEP -25-2002 11:31
H -P GEDTECH
IVE 11
, f
P.03/05
. -12
1 102 441-1 HEPWORTH-PAWLAK LOCATION OF PERCOLATION PIT Fig. 1
1 GEOTECHNICAL, INC. I I
N
FIEILVENTS
'-D
�SCALEX50'
VEA
rlljlri r\
WELL
HWY 82 ROW LINE
GAS
METERS
SE4R LINE
CLEAN OUT
\EX 1,ST I NG
HOMESTEAD
`HOUSE jJf PROPO!
GRAVEI
PR�ERTYILINE
FIV,
EXISTIMS.
OUT-9YILDINCS L
Ao
PROPOSED ?E�TIC FIELD
EXISTING \GGRAVEL MIN
DRIVE L;O BE
ION
RE VED) I PIT
IVE 11
, f
P.03/05
. -12
1 102 441-1 HEPWORTH-PAWLAK LOCATION OF PERCOLATION PIT Fig. 1
1 GEOTECHNICAL, INC. I I
N
SEP -25-2002 11:32
H -P GEOTECH
as 49
HEPWORTH-PAWLAK GEOTECHNICAL, INC.
TABLE I
PERCOLATION TEST RESULTS
P.04 0_
Page 1 of 2
JOB NO, 102 441-1
Note: Percolation test holes were hand dug in the bottom of backhoe pits and soaked on August
14, 2002. Percolation tests were conducted on August 15, 2002. The average
percolation rates were based on the last two readings of each test.
HOLE NO.
HOLE DEPTH
(INCHES)
LENGTH OF
INTERVAL
(MINI
WATER DEPTH
AT START OF
INTERVAL
(INCHFSI
WATER DEPTH
AT END OF
INTERVAL
(INCHESI
DROP IN
WATER
LEVEL
(INCHES)
AVERAGE
PERCOLATION
RATE
(MIN.(INCH)
P-1
36
15
water added
5 1/8
3 518
1 112
17
35/8
3 118
112
3 1/8
25/8
1/2
25/8
1 112
1 1/8
43/8
31/4
1 1/6
31/4
23/4
112
23/4
2
314
2
1
1
P-2
60
15
water added
water added
water added
5 518
3 518
2
8
3 5/8
3
5/8
3
1 112
1 112
33/4
2 314
1
2 314
314
2
41/4
2 112
1 314
5 1/4
35/8
1 5/8
3 5/8
1 718
1 314
P-3
81
15
water added
water added
water added
3 718
3 118
314
15
3 1/8
2 114
7/8
2 114
1 1/4
1
33/8
2 112
7/8
31/4
2112
314
2 112
1 314
3/4
5 7/8
4 314
1 1/8
43/4
37/8 1
7/8
Note: Percolation test holes were hand dug in the bottom of backhoe pits and soaked on August
14, 2002. Percolation tests were conducted on August 15, 2002. The average
percolation rates were based on the last two readings of each test.
SEP -25-2002 11:32 H -F GEOTECH P.05/05
HEPWORTH-PAWLAK GEOTECHNICAL, IIQC.
TABLE I Page 2 of 2
PERCOLATION TEST RESULTS JOB N0, 102 441-1
HOLE NO.
HOLE DEPTH
(INCHES)
LENGTH OF
INTERVAL
IMIN)
WATER DEPTH
AT START OF
INTERVAL
(INCHES)
WATER DEPTH
AT END OF
INTERVAL
(INCHES)
DROP IN
WATER
LEVEL
(INCHESI
AVERAGE
PERCOLATION
RATE
(MIN./INCH)
P-4
96
15
water added
water added
water added
41/4
3 1/2
314
24
3 1/2
2 3/4
3/4
2314
1 7/8
7/8
2 1/4
1 318
7/8
31/2
2314
314
2 314
1 7/8
7/8
1 7/8
1 3/8
1/
4
3 1/4
3/4
Note: Percolation test holes were hand dug in the bottom of backhoe pits and soaked on August
14, 2002. Percolation tests were conducted on August 15, 2002. The average
percolation rates were based on the last two readings of each test.
TOTFC P.05
a
November 11, 2002
Nancy McKenzie
Pitkin County Environmental Health
0405 Castle Creek Rd., Ste. 10
Aspen, CO 81611
Re: --
HCE File Number 2021059.00 (0218)
Dear Nancy:
0
On October 30, 2002, High Country Engineering personnel observed the construction of the ISDS
for the Roaring River Ranch in Pitkin County, Colorado. One U4-gallonleptic tank and onelft
*ameter septic drywell had been installed. One vent pipe was installed, a total of four are required.
The contractor was notified of this requirement and he indicated that he will install the additional 3
vent pipes. The bio -filter was installed in the septic tank outlet. The minimum pit depth of 11' was
met and verified at 11'6". Screened rock had been placed to the top of the perforated drywell
section. All minimum distances were verified per the plans.
On November 7, 2002 High Country Engineering personnel returned to the construction site. The
placement of all four vent pipes were installed.
It is High Country Engineering's determination that the installation of the system was in
conformance with the intent of the design.
If you have any questions, or need additional information, please contact us.
Sincerely,
HIGH COUNTR ENGINEERING, INC.
�qp0 ftEG/sl
V Q le
Roger D. Neal, P.E.
Project Manager 20,975
923 Cooper Avenue, 14 Inverness Drive East Suite 11-144
Glenwood Springs, CO 81601 Englewood, CO 80112
Telephone (970) 945-8676 - Fac (970) 945.2555 Telephone (303) 925-0544 - Fax (303) 925-0547
/cN
EN%NF iF/N!.
High Country Engineering
923 Cooper Avenue
Glenwood Springs, CO. 81601
(970) 945-8676
Field Report%te:,�,
Conditions: P/ uo?�
Project Name: OA-fWCo nl& n rl� _ 1SD5
.Project Number: O /05y�_i20_
Contractor: _ - - --- - - --
Subcontractor:
Report Pepared By:
A
Time On Site:
Travel Time/Miles:
/Oto —5, u T Aj e -TNs»
w/ TitE Gi,vm✓,vs ,¢
11�— norna,u cc_ 3 (/cxris
/'/lN DAN /7c�r�Lx�
7vL5T4 vGcls %%�? / D�wl'v6,
0:f0c,< k�x 0'=-�
CUM-ALMUMUIRILLALLWILL"
0! • 4�RYvrcc.(../Scar=z.� )ecvr 0S (J�vwEcc (RrY
p fl -[=r C&rr Fll7e-e- OG' ✓ter ��/
0 3 10 -CV (ate -7A&r
a4 • p�,rzw
t
N M
•� t ti • 1 VT 1�j4' , a
,s ,'� • �.. tea 5�.�n ra-.i.J a/ ia� a{�/ •t�yTyrw'
�'��`i�}c¢. �'�Y � �'��� ami ���-' "/k . y a Y.� %F> M. s►".
Drywell/Screened Rock
Effluent Filter
0
0
-7".- - 1.
V7. W A-
wpRoall
ol
X.4
f
1" h •'�"•,n 6
s♦ Gf.� '
',r
F,
t �
log
ev
Invert In Tee 1� 7
IWO
'.' t .PL.L� �1`N'1� Com. • • -
1�•
r
( �
wwO30 SCIMOO
OPFYIP65[O
OIIKWAT
EASIIHC MINNAY TO
C KAMP
FPw0Y0 Y CwIOIR
1 DNMDII • a IS DALL06/PEROMLV1 IS:
LM1.W
MOPE® TO FOIIOR
/
DESION ROW - 1.5 AVEMOE - aa5 VO (0)
AUIE: SL ^_e[ a [tll ll[elMlll menva ny v
MSDNO Y EON.
5530
MSOM w ORDON
liSiµy NMEp I W
TO RYUPCo
MORRtt NANOMV
...INSTALL EFFLUENT FILTER IN WENT.. T. tlrTIET[�[
9 Q M
EOSTIW EETOAM VIE
ESSRHO MNNAD NECMC
ELSIRE VS FOIE
IN
FIN. vATEA UNE
UE
MwO.m LME....
E1ECTtt UW
1
FANT NEW FORPGCEMENT)
NDTE
1. PW CAST MANIME SECTORS TO WEET ASTM C-4711
2. BACKFILL EXCAVATION AROUND STRUCNR FOTO CWPRCTED
1-1/2- MUSHED n TO TOP OF PERORATED SECTWS.
PRE -CAST CONCRETE DRY WELL PROFILE
N.T.S
1. DINIML£ SVULES ME TO BE PROVIDED ARM AND AROUND CD. AS
RECESSMV. TO PREVMT SURFACE SLAM FRU ENTERING ADSORPTION EA,
ANEW
EA INTTw.oO SIDEMLLS MAT SE FOXED TO REAM SOHL DEM$
XCYMSO INSPIRED EXGVAT IOW.
J. W EXCAVATION OF ABSORPTION FIELD IS TOC DOE DARING NET KLTIG
NO INE OF FLAMER LIRE VMHCLIES MR FORMATION MG E MOSH IS EO
4. wA)ITABLE MTERIAL EXISTING WITHIN THE BED SHALL BE EXCAVATED NO
WJti1LL RMLL CONSIST BE ONSITE SELECT M PITfM WTESIAL.
GRAPHIC SCALE
(M PONT)
ICED B,
a
Q
Z
PROJECT Nr,.
2021059.00
SCALE: 1--2=
DULL M IN NIM TNN O IELO DOOREFF
t. ALL CATIONS
OF I FEE OPSME E OMi
ALL WDwS ON ISENIS ME SEWAGE OISNSRL sNOED t. IMA' G1
ALL U1 M LIC AS.
M[ NOT SIBLE
THE CwiMRQ 9IN I M RESPONSIBLE rw SARI TIONS.IC DETAILS AS
EENT SHALL FDA SPE TAILS
ME RRASD 10 IM 11( AWVE 1[Ni IbKD RfORATIOO.
2. Rn FOR ®:
1 DNMDII • a IS DALL06/PEROMLV1 IS:
)S CPO . AVEM
NGE I V FLOW.
/
DESION ROW - 1.5 AVEMOE - aa5 VO (0)
AUIE: SL ^_e[ a [tll ll[elMlll menva ny v
SEPTIC 14C:
AUC pK
IMIYY TOEAL TNN SIS:
liSiµy NMEp I W
TO RYUPCo
0 •I DAMIS [ b N6 - EOE W
IRIKL UE 1 WOANLw TIMI WITH W"
...INSTALL EFFLUENT FILTER IN WENT.. T. tlrTIET[�[
9 Q M
HAWKED AOttMTIw AREA.
A - [MUYIYM FLw
KP.ATId MR - I]IVIXI
E[ O EVELL:
DIARERR OF PIT - e.0': TRERTO6: ROTTW NSA. - b SO
EPTN BELOW IRLEr- e.0': THEREFORE. SRALLE AREA - ISO BE
FAL MOATION PREAT ED -CTM Sr.
CgRLMRml
I
S. MEAN WTS Nrt RWIRD AT ALL CWS AW AT LECST FKR IRS
FEET MOC THE NEADEE ...
S .
♦. M WI NINETw SULU 4 RE.IRE 1. INSTALLING ALL
SWEET EWW
RATES T.. [AIOIEWS. PRIM TO THE IH 11. AREA.
TO NEVEM IMNTMrIw.
E. TOPSOIL CO14R MV BE .1. (NITH I MET YIH.MW) TO ALLOW
SOW
LMSNER'..
s. IISTKL RISER M NECESSARY TD MING ALL ACCESS MINTS TO
n TNI. OSJUtr MD, IN [IML DRAM.
_ .�//
W' a A a A.
]. 0 ALL MI E R D CONFORMS NF1 WE VARIED HO IEQSSMY . LOIO
M ALL YINIYY OISTN4[5 MO AE/ES H[[T ilpfE REQUIRES.
II RIE
�E'T//_OFM
S. �INEGNWiMLLEAS rRblMTIw
MONINAME DRIS NECESSARY.
AMICABLY
S. NILS InrORNrlw FRw IWOMTION NL PERJILATION TESTING
PWW IOED M N.P O wnw, W.. JM W. 102 Hl -1. WCVST le. MOO].
SEWER CLEAN OUT DETAIL
10. m„I.m IFNG�SO W—TI2EOry EMMW = 1'.VNNIT NEAT WE
A.T.
EWINEMY5i MftR RMNSIWEfm STATIM BEFORE EAEVILL
AND Mw IC REPORT TO munV.
Tr. THE ASTM IS SI SD FOR TYPICAL EREMITIC NINETIES ONLY, OtlaVASH
N• (M4H O
ITS OR WATER �T[KRS
M f.LLP. SI ASAINE 0 NNET PWE IN NRMIESE �V10 INTO THIS SEVEN.
NAM
la. SITE NM INFURIATION FRESH WE CEDTEM AW OIER.
IS. INSTALL OLLFMMOWE R PIR VDEPTH 15
WO INATION R SMKRM
•l•
LESS TH.W E.0 FEET,
14 THE INDONESIA BULL WE ONrtACTW FM 9CT
SIDE INEION MOM TO
[
MIXFILLING BE ASTM WPD'EMR,
11, MEId CP pHY11CLL BISEI w PFM. MR. EIRE COSTMIMS AND SDIL
PI 11 IWIGTIW 1' OF CMUXIC FILL IM S' BE w-91TE M.W1M FILL
H
rM�TM SON rMOENTS WELTING SLIMLY SAME ONAM WITH DOWRIES
NDTE
1. PW CAST MANIME SECTORS TO WEET ASTM C-4711
2. BACKFILL EXCAVATION AROUND STRUCNR FOTO CWPRCTED
1-1/2- MUSHED n TO TOP OF PERORATED SECTWS.
PRE -CAST CONCRETE DRY WELL PROFILE
N.T.S
1. DINIML£ SVULES ME TO BE PROVIDED ARM AND AROUND CD. AS
RECESSMV. TO PREVMT SURFACE SLAM FRU ENTERING ADSORPTION EA,
ANEW
EA INTTw.oO SIDEMLLS MAT SE FOXED TO REAM SOHL DEM$
XCYMSO INSPIRED EXGVAT IOW.
J. W EXCAVATION OF ABSORPTION FIELD IS TOC DOE DARING NET KLTIG
NO INE OF FLAMER LIRE VMHCLIES MR FORMATION MG E MOSH IS EO
4. wA)ITABLE MTERIAL EXISTING WITHIN THE BED SHALL BE EXCAVATED NO
WJti1LL RMLL CONSIST BE ONSITE SELECT M PITfM WTESIAL.
GRAPHIC SCALE
(M PONT)
ICED B,
a
Q
Z
PROJECT Nr,.
2021059.00
1
m
M
I'l /
U,L t,e k S c?e�
c Y o l
3
}
M
J
1
a '
.
'p3�k
f �
z
I�
J
9jp
W
I f.
3 9.
_
°
� t
Ld
k }
�Fg
:
\
- CAS 1.I_TER
E TE R
'0 3 _ REMOVED
! --
VICINITY MAP
�`"-- .tie:.✓'`�---- '�--.
... -`-� Y .,__ �`'^ \ ,.•�'�*: s>�j";'r+e_. 4'
•'•,,� �
UNOCCJPIED ..
STRUCTURE
._„_ _ „, r�,
SCALE. 12000
. , ,_..,._.. _- PRII$OSED. W,,,. ATE'R-NNE ' •„_, ..._- _ � .� `ti
/
�.,, _
PROPOSE ELECTRIC""tINE-�- _. - %
-�, --.__`'�. �„ `��'`.
1
CONSTRUCTION SHALL BE I N ACCORDANCE WITH THE GARF I ELD COUNTY
a
/ ,..,. -__. �.,. .-_ ,'--_...,. .....,'.
UE VE -
..- e Y
�,._ 1... A .._...,,\ �`.....�-�.. \
-.........--
.
CH!A DUnI SEWAGE ISPOSAi. SYSTEMS. EVEN THO!!GH
RE ._ - ? ONS OF ND V _ E D -
�.` _
�"� U / "-�-
— UE
W—'
._ _
- J\ / \
-_..,.,_ SHED -,#1 REFITTED \.
._-... _ " A I
\-�,._ ��... ijr
ALL SUCH REQUIREMENTS ARE NO' SPECIFICALLY NOTED ON THE DRAWINGS.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUCH SPECIFIC DETAILS AS
711
—��"
`
`�C�� UE U _
- W
FOR BATHROL•!d \' _.-
'"'---
�� APPROX. 165 S F, �,• .. 4
(� ,.-�.
`~"�
7_.
ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS.
FLOW
z
W—W
�y__.��� UE
W
_ _ i ,\ ``.�. •.� 0,.,,�-„`'": 4i
�•..�� %° a\. �" EXISTING GAS`LINE�. ~• ”" -�.,.^ ��\ \�� �.._ ,_ �.. „';A'
FOR BED:
1 BEDROOM » 2 PERSONS/BEDROOM » 75 GALLONS/PERSON/DAY IS:
o
_, ^._- ,.,.
"-�._^ � -�� •\\
.,.,,e.... ',.
�
N
...TO BE ABANDONED \� `" "�\ P
\
WEST OF THIS JLINCT16N`4 ..,-,. `�� ", `�, w..1-�. `�`•,
'^'.•,. `'`.•...
�.
DESIGNDFLOWVE AGS DAILY FLOW.
225 GPD (Q)
a
N
V)
',- GAS LINE.�-�
TO BE REMOVED ,.
„
`•..•-,... \ . ,;• ,,•,
... \ ,. \ "`^ _, 7Q "' ` ,`� •'
�, "" "' �.
INSTALL CLEANOUT -..._ `�'�._...., C>a1 \.
NOTE:
STRUCTURE IS FOR RESTROOM PURPOSES ONLY.
00
! - ,... INSTALL 4"0
PVCSEWERI 1
I ); '
_ 1 ...-.... _.,__ '`-,,. ....�
(PER DETAIL) - .. a` -,. `\ '�.\ .�
.1..� EXISTING DRIVEWAY ""^-.. ,, ti
\\
SEPTIC TANK:
MINI MUM TOTAL TANK SIZE :
w
w
Q
w
(TYP ��'
L� •
'AIR VENT (TYP.) ,Lp • �Y�
"' -. --_ ' -.TO BE•REMOVEp "" REMOVABLE PVC CAP
`'�- , �`-..,.` --.� "'\ N, • INSTALL MARKER IF CAP
F - '^ "�•�,-• '� IS TO BE BURIED
Q * 1 DAY 24 HRS * 30 HRS = 282 GPD
INSTALL ONE 1000 -GALLON TANK WITH BAFFLE
0
ae
�
Y
(PER .DETAIL)
,' .. _
..may,
1
INSTALL 1000 GAL OS
***INSTALL EFFLUENT FILTER I N SEPTIC TANK OUTLET***
-. I INSTALL 4'm DRYWELL\--`
(PER DETAIL)
, -,.. SEPTIC TANK I ` "" FINISH GRADE
�-`-'�1 ! "�--„_ �
- .."',.,
''• I `� \.
STANDARD ABSORPTION AREA;
t0
v
*1
VV _-.._.._...__ I - .; 1 p :.
. .. '100' (MIN:i FROM WELL--'-----'-��1� ,- _
�< - TO SEPTIC .DRYWELL =.-� `'
"r 1 ...sAll__, o,. 4.Q.o
w� " 0_00
INSTALL BIO -FILTER y.; �`'`�,,,� - °
.. AT TANK' OUTLET "''ti,' -f., ,1T'. I- \
-�
A = Q � Q=MAXIMUM FLOW
TIO 'n.
5 t=PERGOLA N RATE = 17 mi / n.
I _-
- 2 255 _> A = 185 SF
10' MIN. �.
_ ..� -.�.
u„ -�
04
USE F
U 0 DRYWELL
z
W 9
PROPERTY LINE S
1
.. " 1
'°r
\
DIAMETER OF PIT = 8.0': THEREFORE: BOTTOM AREA = 50 SF
DEPTH BELOW = , SIDEWALL AREA = 150 SF
U
®
"
4 COUPLING 4
-
RISER 3'
TOTAL ABSORPTIONPROVIDEDTHEREFORE,
UI BENDS AND AT LEAST EVERY 100
CLEAN OUTS ARE REQUIRED AT A
W
z
W
Lo
-..
- ' -
0 SEWER.LL
FEET ALONG THE H U—
����[[
UNOCCUPIED STRUCTURE
4"
45' SWEEP BEND 4.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL
V
0
Cl) C13
`.
' ,,.. f w.,, -.
WATER TIGHT COMPONENTS, PRIOR TO THE ABSORPTION AREA,
z
-
2 X
PROPOSED
'-" �\
4" SEWER LINE
TO INFILTRATION.
W
0-
DRIVEWAY PROPOSED POND
-
'' _..,. `/ -
5.
PREVENT
TOPSOIL COVER MAY BE VARIED (WITH 1 FOOT MINIMUM) TO ALLOW
W
�.
LANDSCAPING.
s zo
f �-, -^s
/
6.
INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS TO
WITHIN ONE-HALF FOOT OF FINAL GRADE
II.0
F�
.
MAY VARIED AS NECESSARY AS
4" 4"
p� 7.
LOCATIONS OF ALL COMPONENTS BE LONG
j Z
x
��,
AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED.
OW
z rc
n
PVC WYE
8.
CLEAN OUT
PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM ABSORPTION
FIELD AREA USING DRAINAGE SWALES AS NECESSARY
U
OD
Q �°D N
ASSEMBLY
T
W
nh
AIR VENT (4 REQ'D)
(SEE DETAIL AND PLAN VIEW FOR PLACEMENT)
9
SOILS INFORMATION FROM INFORMATION AND PERCOLATION TESTING
PROVIDED BY H.P GEOTECH, INC., JOB NO. 102 441-1, AUGUST 16, 2002.
+
" ^p ^
0
v
m Z
LU
--
SEWER CLEAN OUT
DETAIL 10.
THIS DRAWING DOES NOT CONSTITUTE AN ISDS PERMIT. PERMIT MUST BE
_
OBTAINED FROM APPROPRIATE CITY OR COUNTY OFFICIALS.
N.T.S.
ENGINEER MUST OBSERVE CONSTRUCTED SYSTEM BEFORE BACKFILL
AND PROVIDE REPORT TO COUNTY.
INSTALL FILTER FABRIC
OVER NATIVE MATERAIL
1i.
THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH
24" (MIN.) OF
OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS
FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM.
OR
SLOPE AWAY SLOPE SLOPE AWAY TOPSOIL
-'
12.
SITE PLAN INFORMATION FROM HP GEOTECH AND OWNER.
--
``
° /,%
/j/�/ ,/ ,',/ , /CONE SECTION OR, / e° ,' / , ,' / ,',',/ �',' ! ',',!./',' /\%//
\\ / / / ' FLAT SLAB TOP ' / , / , ' / , ' / / /
13.
14.
INSTALL BLUEBOARD INSULATION OVER SEWER PIPE WHEREVER DEPTH IS
LESS THAN 5.0 FEET.
FHE ENGINEER SHALL BE CONTACTED FOR SITE INSPECTION PRIOR TO
`\
,' ,'
BACKFILLING OF SYSTEM COMPONENTS.
/ ,/ /
,'NATIVE FILL' ,', / , , , , / / , / , // /
15.
DESIGN OF DRYWELL BASED ON PERC. RATE, SITE CONSTRAINTS AND SOIL
,
, MATERIAL'/
PROFILE INDICATING 1' OF ORGANIC FILL AND 5' OF ON-SITE GRANULAR FILL
WITH WOOD FRAGMENTS OVERLYING SLGHTLY SANDY GRAVEL WITH
INLET PIPE TO ENTER' /','/\\//
T
COBBLES
AND BOULDERS.
(
LEGEND
,
' 48" ' /,'DRYWELL AT A DEPTH OF \\\
'STANDARD o /
3' _._.
\\/�/ '//',' ' RISER;' ,
\ \ / , , 2' TO 5 BELOW GRADE
� PROPOSED BUILDING \\\ / , ,, ,',/;SECTION(S) ,�
\%'\
PROPOSED DRIVEWAY
NATIVE FILL MATERIAL•' '
C AL AFF -A NOTES
DRIVEWAY TO
COUPLING ILLMA
',/ /
//\\�
CO
EXISTING
'- BE REMOVED
,'�/ , /',',/ /',',/ ,',,',' ,'
' i' +-' ' ' �'�'
1.
DRAINAGE SWALES ARE TO BE PROVIDED ABOVE AND AROUND BED, AS
r
,
NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING ABSORPTION AREA.
U)
PROPOSED 2' CONTOUR I
SANDY GRAVEL W/
1O
0
=
J
\ z COBBLES & BOULDERS
2.
AREA BOTTOM AND SIDEWALLS MUST BE RAKED TO REMOVE SOIL SMEARS
p
V
Q
v
\
INCURRED DURING EXCAVATION.
a
5530 PROPOSED 10' CONTOURCO
_
[ifINSTALL
SCREEN
_ DOUPLING
GLUE Z
\ •
3.
NO EXCAVATION OF ABSORPTION FIELD IS TO BE DONE DURING WET WEATHER
AND USE OF RUBBER TIRE VEHICLES OVER ABSORPTION AREA IS PROHIBITED
_i
0
Cl)-
EXISTING 2' CONTOUR COVER.
PERFORATED RISER °� 0 1_1/2" �\
SECTION(SJ
j
18"
SOLID PIPE \�
SRONEED
4.
UNSUITABLE MATERIAL EXISTING WITHIN THE BED SHALL BE EXCAVATED AND
BACKFILL SHALL CONSIST OF ONSITE SELECT OR PIT -RUN MATERIAL.
}
W
EXISTING 10' CONTOUR
"��,�,
o
PROPERTY BOUNDARY \�j\\\�
o
— EXISTING SETBACK LINE
o o
„1
V V
®Q
R
�O
j
O
z
Z
<
Q
W
Cf)—
Q
O
4'
/ ` °
ir
4" 0 PERFORATED PIPE
e..
O
OVERHEAD ELECTRIC
WRAPPED WITH FILTER 8' (MIN.)
�9"^'i5^,X-
S .
s
-------
-- - ----- -------- •-----„- --------- EXISTING
..... F X OE o
FABRIC
f
- - - - EXISTING GAS LINE SOLID CAP FOR
SUPPORT ®BOTTOM O
X ( OF TRENCH OR BED O
NOTE:
”°°'
AtifT Fit(-�N?.A
GRAPHIC SCALE '`'
Z
PROPOSED WATER LINE
W
1. PRE -CAST MANHOLE SECTIONS TO MEET ASTM C-478
20
20
N O O 10 40 00
2. BACKFILL EXCAVATION AROUND STRUCTURE WITH COMPACTED
PROPOSED UNDERGROUND /\\/\\/\/
a
PROJECT
NO.
VE
1-1/2" CRUSHED STONE, TO TOP OF PERFORATED SECTIONS.
ELECTRIC LINE
Z
RECEIVED
�-. ..~_ ...,�,.,•_..._, �...,.. �..,,,: �,�., �_. r
PRE -CAST CONCRETE DRY WELL PROFILE
(INFEET>
1 inch = 20 ft.
2ozloss.00
AIR VENT
DETAIL
SEP 0 3 2002
N.T.S.
N.T.S.
PITKiN COUNTY
SHEET
ENVIRONMENTAL HEALTH
1