Pit ounty Environmental Health Depart t
Pe. for an Individual Sewage Disposal em
0405 Castle Creek Road, Suite 10, Aspen, Colorado 81611
Phone 970-920-5070 / FAX 970-920-5077
Permit # 05032 Parcel ID # 2473-201-00-005
Type of permit New( ) Repair( x ) Addition/Remodel to House( ) VENTURA CABIN
Name of Owner Connell Development Company — Diamond J Ranch
Street Address 26604 Frying Pan Road
Property legal description
Size of lot 26.872
Total square footage of the house 7 cabins
Water source Private well (pending non -community groundwater system approval)
# of bedrooms in house
Caretaker unit
# of bedrooms in caretaker unit
Designed for what # rooms (list)
# of offices, lofts & similar sized rooms in house
Total square footage of the caretaker unit
# of offices, lofts & similar sized rooms in caretaker unit
7 seasonal cabins = 13 bedrooms
Permit information
Designed by High Country Engineering, Jeff Odor
Mailing Address 1517 Blake Avenue, Suite 101, Glenwood Springs, CO 81601
Perc rate 26 mpi Profile hole depth 8 ft Depth to groundwater or bedrock Greater than 8 ft
Minimum Septic tank capacity See engineer design Minimum Absorption area 1624 sq ft w/ 30% reduction
Rau
Septic permit approved per compliance with the engineer design and specifications dated June 24, 2005 and
memo dated June 30, 2005 regarding the use of standard sized chamber units. Any changes must be approved
by this department and the design engineerrp for to them being made.
Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin
County ISDS regulations. Any area where a sewer line crosses a water line must be encased within 10 feet of the
crossing. The field must be at least 20 feet from any occupied building. The field area should be staked out
prior to installation before digging to assure setbacks can be met.
Two tanks will feed into the system. Tank #1=2000 gallons, tank #2=2000 gallons. Each tank must be two-
compartment and have effluent filters on the outlets. A 1000 gallon dosing tank will distribute effluent to the field. A
distribution box will distribute effluent to two manifolded areas of a bed. The bed should consist of 7 rows of 15
Standard chambers.
This department does not endorse any brand of products. This permit must be kept on-site during installation.
The engineer must do a final inspection of the installation and submit an as -built letter to this department. This
department must also be called for an inspection with a minimum of 48 hours advanced notice.
'Revegetation over the area of the field is very important for the functioning of the system. Pitkin County has guidelines that must be
followed to assure the plants that are introduced are appropriate for the conditions of the area. The use of native plants is strongly
Permit approved by: O (� .r( Q k-U)C (U Date: (�,,
Plans and specifications of the proposed individual sewage disposal system have been reviewed and are considered
satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin
County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was
issued unless system construction has commenced or an extension has been approved in writing by the Department.
As -built drawings must be included with this permit before the final approval will be issued.
Installer: Te�
cy
Final approval:
VST► UPO CABtN
PITKIN CkNTY ENVIRONMENTAL HEALTH DEPARTMENT
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM
0405 Castle Creek Road, Suite 10, Aspen Colorado 81611
Phone (970) 920-5070 Fax (970) 920-5077
Name of OWNER Connell Development Company
Owner's Mailing Address P.O. Box 541057
City, State, Zip Dallas, TX 75354-1057 Business Phone: (214) 357-4694
Home Phone: Email Address: ths@connellcompanies.com
Primary Contact Person (all communication regarding this perrnit will go through this person)
Name Thomas H. Stewart
Company Connell Development Company
Contact Mailing Address P.O. Box 541057
City, State, Zip Dallas, TX 75354-1057 Business Phone: (214) 357-4694
Cell Phone: Fax: (214) 357-4953 E-mail Address: ths@connellcompanies. co
at 920-6160 or at www.pitkinassessoror0 )
Building Permit # (if available)
Street address of property 28604 Fr'
Legal Description: Lot see attqiafd
Size of lot: 26.872 acres.
Total square feet of house
Caretaker Unit: Attached (
1344
2 4 7 3_ 2 0 1. 0 0 .0 0 5
Pan Road Meredith. CO 81642
,Filing ,Subdivision
Type of proposed structure: Log Cab ix
Detached (
8 of bedrooms (potential) in house 3
Permit is for New Home( X ) Repair due to failure ( ) RemodeUAdddion ( ) Emergency use ( )
Water Private well ( X ) Spring ( ) Stream ( ) Community/Public Water System ( )
If community system: Name of system
The fee for a ISDS application is $600 for a permit that takes 6 hours or less for the department to approve. If approval takes
longer than 6 hours, a rate of $100 per hour will be charged. The maximum fee is $1000. The basic fee of $600 is due at the
time of application. The remainder, if any, will be due in two stages: first, at the time of issuance of the ISDS permit, second,
before final approval of the ISDS permit.
Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information is true and
accurate and that I have provided true and accurate information on locations of all existing and proposed wells, contour
intervals, buildings, property lines, ditches, slopes, waterlines, springs, suction or irrigation lines, drinking water cistems, drain
tiles, irrigation ditches, lakes, water courses, streams, floodplain, dry gulches, and existing septic systems. I hereby certify that
any such features not shown on attached site map are not present. Issuance of the permit does not imply the approval of any
other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all approvals
and permits have been obtained.
The Pitkin County Environmental Health Departme County and employees of these agencies will be held harmless
should the individual sewage disposal system fai r mal n on. The permit to construct is issued on information submitted by
the applicant or his/her representatives. The er ume�full responsibility in case of failure of the system.
Signature of applicant z::/M-/)044.
1
Date
�if e,r
Received by N;
Receipt # V
Date
o 5
Pitkirj&unty Environmental Health Departm t
Per . or an Individual Sewage Disposal S)Wm
0405 Castle Creek Road, Suite 10, Aspen, Colorado 8 611
Phone 970-920-5070 / FAX 970-920-5077
Permit # 05026 Parcel ID # 2473-201-00-005
Type of permit New( ) Repair( ) Addition/Remodel to House( ) VENTURA CABIN
Name of Owner Connell Development Company — Diamond J Ranch
Street Address 26604
Property legal description
Size of lot 26.872
Pan Road
Total square footage of
Water source Private well (pendinq non-com
# of bedrooms in house _
Caretaker unit
# of bedrooms in caretaker unit
Designed for what # rooms (list)
Designed by
Mailing Address
# of offices, lofts & similar sized
Total square footage of the caretaker unit
# of offices, lofts & similar sized
3 seasonal cabins = 7 total bedrooms
Permit
Jeff Odor
in house
in caretake/unit
1517 Blake Avenue, Suite 101, Glenwood %rings, CO 81601 / / g
Pere rate 26 mpi Profile hole depth 8 ft Depth to Npundwater or bedrock
Minimum Septic tank capacity See engineer design Minim
area 624 sg6w/ 50% reduction
Septic permit approved per compli ce with the gineer design and specifications ed April 8, 2005. Any
changes must be approved by this part lent an he design engineer prior to th being made.
Minimum horizontal distances betwee components the system and ph/features features shall conform to the Pitkin
County ISDS regulations. Any area w re a sewer lin crosses a water lin ust be encased within 10 feet of the
crossing. If the absorption field comes thin 25 feet o any water lines y must also be encased.
Prior to installation of ONsystem, and 8 t ro ' hole mustpO dug in the area of the proposed field to
reconfi epth to grou water. This department must be c tacted to evaluate findings in the profile hole
prior to ins tion of this ystem. Two tanks will feed into a system. Tank #7=1000 gallons, tank #1=1000
gallons. Each 'essamber
t be\dorany
partment and have effl t filters on the outlets. The system will consist of 64
Quick 4 gravalserial configuration p engineer design. The trenches must be separated by
at least 6 feet rbed
This department does not brand of pr cts. This permit must be kept on-site during installation.
The engineer must do a finaion of the in Ilation and submit an as -built letter to this department. This
department must also be caln inspecti with a minimum of 48 hours advanced notice.
'Revegetation over the area of the field is very impertant for the functioning of the system. Pitkin County has guidelines that must be
followed to assure the plants that are introduce re appropdate for the conditions of the area. The use of native plants is strongly
Permit approved by: ( °.cit" .V o C�_ Date: D� 2 0 10 5
Plans and specifications of the proposed individual sewage disposal system have been reviewed and are considered
satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin
County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was
issued unless system construction has commenced or an extension has been approved in writing by the Department.
As -built drawings must be included with this permit before the final approval will be issued.
Installer:
Final approval: Date:
9
CIVIL ENGINEERING
November 28, 2005
0
An EmployeeOwnedCompany
Carla Block
Pitkin County Environmental Health
0405 Castle Creek Rd, Suite 10
Aspen, CO 81611
Re: Diamond J Guest Ranch ISDS
0
LAND SURVEYING
HCE Project Number 2041709.00 x 0218
Ventura ISDS ^ n p>
Dear Carla:
The following letter is to confirm the engineer's acceptance of the installed septic system
for the Ventura ISDS of the Diamond J Guest Ranch on Frying Pan Road (County Road
4). The design included a single separate individual sewage disposal system (ISDS) for
cabins C4, C5, C6, C7,C10, C11, and C12. Based on field inspections, the ISDS fields
have been installed per the intent of the plans and specifications.
The installed collection piping and tanks were changed from the original design due to
existing site conditions. A record drawing of the installed system is provided.
If you have any questions, or need additional information, please contact us.
Sincerely,
RDN/Imm
Enclosure
1517 Blake Avenue, Suite 101
Glenwood Springs, CO 81601
970.945.8676 phone
S 970.945.2555 fax
INC.
www.hceng.com
14 Inverness Drive East, Suite F-120
Englewood, CO 80112
303.925.0544 phone
303.925.0547 fax
•
October 28, 2005
Thomas H. Stewart
P.O. Box 541057
Dallas, TX 75354-1057
Re: Parcel ID #: 2473-201-00-005
Property Address: 26604 Frying Pan Road
Permit Numbers: 05015, 05025, 05031, and 05032
Dear Mr. Stewart:
As per our correspondences to you on July 6 and 20, 2005 as well as September 5, 2005
(separately for each permit number), the Environmental Health & Natural Resources
Department would like to remind you that we are still unable to complete the processing
of the Individual Sewage Disposal System (ISDS) permits for the above stated
residence/property.
It is mandatory that our office receives an "As Built" letter for each permit from the
engineer who designed the system. The letter will confirm that they observed the
installation of the system as designed. Any changes to the system must be noted in the
letter or by a new set of plans. The Building Department will not issue a Certificate of
Occupancy for this property until they are notified that the ISDS permit process is
complete.
This office must receive the "As Built" letters from the engineer no later than November
17, 2005.
Please contact me with any questions. Thank you, in advance, for your help and
cooperation in this matter.
Sincerely,
Alicia Gomez
Administrative Assistant
Environmental Health & Natural Resources
cc: Jeff Odor, P.E., High Country Engineering
IN
lun•30. 2005 9:20AM HIGH�fOUNTRV ENGINEERING No -1754
CIVIL ENGINEERING LANDSURYR 11146
M bplr�OwtlC<sw.v
P - 2/6
MEMORANDUM
TO: CARLA BLOCK
FROM: JEFF ODOR, HIGH COUNTRY ENGINEERING
DA'T'E: 6.3405
SUBJECT: DIAMOND J GUEST RANCH JUN L 6 2005
PITKIN COUNn•
HCE PROJECT No: 2041709.00 ENVIROftI1.tE�TgI HEg11l.1
I am taking this opportunity to address the number and type of infiltrators to be used for the
Ventura and Cabin Community ISDS's. The design submitted for each system specified the
Infiltrator System Quick 4 infiltration unit. I am proposing the use of a standard infiltrator
unit manufactured by Infiltrator Systems, the standard BioDiffuser Chamber manufactured
by ADS, or other equivalent product. These infiltrator units have an infiltration area of 15.5
sf per unit associated with it. By using these infiltration units the total number of units will
decrease from the proposed design, however in both designs the total required area will not
change. The following discussion refers to standard infiltrator units as any of the approved
equivalent products available.
The Ventura Cabin has a required infiltration area of 2320 sf. This is based on a design flow
of 2275 gpd and a percolation rate of 26 min/inch. Since infiltrators arc being used in a bed
configuration, a 30% reduction in area is allowed resulting in a required area of 1624 sf.
Each standard infiltrator unit allows for an area of 15.5 s£ This results in a required 105
standard infiltrator units. It is my recommendation that these units and installed in the same
configuration as the illustrated design (signed 6-27-05). The only difference between the
illustrated design and the infiltrator units being proposed here is the number of units per
row. The proposed design decreases the number of units per row from 11 Quick 4 infiltrator
units to 7 standard infiltrator units. The footprint of the previous layout using the Quick 4
15 17 8u AVEWE, Surra 10
GLENWOOD SrM" 'CO a 1601
9709468676•PNON¢
970*4525W - FAX
WWWAGSNG.aon1
14 lmr NCM DRrvc EAST, suns F120
ENGLEWOOD. CO 601 13
303r92505" -P"0445
303925.0547•FA[
lun.30 2005 9:21AN HIG*NTRY ENGINEERING
No•1154
is
P - 3/6
infiltrator unit had a bed dimension of 44' long (i l units) and 45' wide (15 units). Utilizing
the standard infiltrator units, the footprint dimensions are 43.75' long (7 units) and 45' wide
(15 units).
The Cabin Community ISDS proposes a required infiltration area of 1217 sf based on a
design now of 1925 gpd and a percolation rate of 20 min/inch. As with the Ventura Cabin,
infiltrators are being proposed in a bed configuration allowing for a 30% reduction in
required area. This results in a required area of 852 sf. Using the standard infiltrator units
having 15.5 sf per unit allowed, a total number of 55 standard infiltrator units are required.
The current design indicates 4 rows of 22 Quick 4 infiltrator units having a footprint of 12'
wide by 88' long. As the total number of infiltrator units has changed, the detailed layout
may be altered. The design of the system has not changed and will remain an equilateral
distribution system with manifold piping at each end. However, the absorption bed
configuration may consist of 4 rows of 14 resulting in 56 standard infiltrator units or if the
topography allows 5 rows of 1 lunits may be installed resulting in 55 standard infiltrator
units. If 4 rows of the standard infiltrator units are used the bed dimensions are12' wide and
97.5' long resulting in minimal cbange in the absorption bed footprint, and minimal affect
on the setbacks. Installing 5 rows of 11 units results in an absorption bed of 15' wide and
68.75' long. The change in bed dimensions will change the setbacks slightly, however the
changes will not affect the design. The only setback that is impacted is the setback to the
ditch. The PVC liner adjacent to the bed provided conformance to the setback to the ditch.
This PVC liner is still required for the proposed bed utilizing the standard infiltration units.
If any additional information is requested, or if there are any questions or concerns regarding
this information, please feel free to contact me at your convenience.
1617 OLAKE AVENUE. SURE 101
GLENWOOD SPRRIG9, CO 81601
9709466676 • PNONE
970.94FP2555 • FA%
161
wWyy.HCENG.fOM
14 NVSRNX" DRIVE EAST, Su1TE F•120
ENGIEWOOD, CO, 80112
303-9260541 • ►NONE
30"250547•FAa
• r
PITKIN ENVIRONMENTAL HEALTH DEPARTMENT
ISDS DESIGN CALCULATIONS
Owner's Name
Parcel ID #
House Size (sq. ft.) (75 gpd, 100 gpd, or 130 gpd)
Number of Bedrooms in Main House
Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House
Number of Bedrooms in Detached Caretaker unit
Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit
(If the caretaker unit is ATTACHED, treat as if part of main house.)
Average Daily Waste Flow 1300
State Review Required? no
Perc Rate - Hi (T)
Design Flow (Q) = # potential bedrooms X 2 people/bedroom X gpd X 1.75
Q= 2275
Minimum tank capacity 2843.75 gallons
Absorption Area (=Q/5 X SQRT perc rate)
A = 2320.0539 sq. ft. of absorption area required
150 gravelless chamber units without reduction
# of Perc Holes Required: 3
1 in every soil type? Spaced uniformly over
OUICK 4 9-8
A = 1160.0269 sq.ft. with 50% reductionTRENCHES
118 gravelless chamber units with reduction
STANDARD
A= 1160.0269 sq.ft. with 50% reductionTRENCHES
75 gravelless chamber units with reduction
EQ 36
73 EQ36 units in TRENCHES
SETBACK FROM WELL
# of feet = 202
SETBACK FROM POND, STREAM OR IRRIGATION DITCH
# of feet = 152
SETBACK FROM DRY GULCH
# of feet = 127
601
QUICK 4 9.2
1624.0377 sq ft 30% reduction BED
177 chamber units with reduc.
1624.0377 sq £t 30% reduction BED
105 chzunber units with reduc
units in a
PITKIN ENVIR• ENTAL HEALTH DEPARTMEO
ISDS DESIGN CALCULATIONS
Owner's Name
Parcel ID #
House Size (sq. ft.) (75 gpd, 100 gpd, or 130 gpd)
Number of Bedrooms in Main House
Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House
Number of Bedrooms in Detached Caretaker unit
Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit
(If the caretaker unit is ATTACHED, treat as if part of main house.)
Average Daily Waste Flow 900
State Review Required? no
Perc Rate 26 (T)
Design Flow (Q) = # potential bedrooms X 2 people/ bedroom X gpd X 1.75
Q= 1575
Minimum tank capacity F-rate
llo 1 �/
Absorption Area (=Q/5 X SQRT P
A = 1606.1911sq. ft. of absorption area required
104 gravelless chamber units without reduction
T51
2 r� P1 e c�
C� �jG�nwt-S�
# of Perc Holes Required: 3
1 in every soil type? Spaced uniformly over proposed area?
QUICK 4 9_SUQ ICK 4 9.2
A = 803.09557 sq.ft. with 50% reductionTRENCWS 1124.3338 sq ft 30% reduction BED
82 gravelless chamber units with reduction 122 chamber units with reduc.
STANDARD
A= 803.09557 sq.ft. with 50% reductionTRENCHES
52 grave0ess chamber units with reduction
EQ 36
50 EQ36 units in TRENCHES
SETBACK FROM WELL
# of feet = 146
SETBACK FROM POND, STREAM OR IRRIGATION DrrCH
# of feet = 96
SETBACK FROM DRY GULCH
# of feet = 71
�U
1124.3338 sq h 30% reduction BED
73 chamber units with reduc.
90 EQ36 units in a BED
H�
o 'otech
HEPWORTH-PAWLAK GEOTECHNICAL
October 20, 2004
Hep-Pawlak Geotechnical, Inc.
5020 unty Road 154
Glenwood Springs, Colorado 81601
Phone: 970-945-7988
Fax: 970-945-8454
email: hpgeo®hpgeotech.com
Tommy Stewart
P.O. Box 541057
Dallas, Texas 75354-1057
Job No. 104 456-1
Subject: Subsoil Study for Foundation Design and Percolation Testing, Proposed
Cabin, Diamond J Ranch, 26604 Frying Pan Road, Pitkin County,
Colorado.
Dear Mr. Stewart:
As requested, Hepworth-Pawlak Geotechnical, Inc. performed a subsoil study and
percolation test for foundation and septic disposal designs at the subject site. The study
was conducted in accordance with our agreement for geotechnical engineering services to
you dated October 11, 2004. An additional percolation test was requested in the area
between Cabins 1 and 2. The data obtained and our recommendations based on the
proposed construction and subsurface conditions encountered are presented in this report.
Hepworth-Pawlak Geotechnical, Inc. previously conducted percolation testing for a cabin
in the area of the existing corral and presented our findings in a report dated July 29,
2004, Job No. 104 456.
Proposed Construction: The existing cabin at the site (Cabin 5) will be relocated in the
area between Cabins 1 and 2, shown on Figure 1. The proposed cabin will be a single
story log structure over a crawlspace. The cabin will be about 1,344 square feet in size.
Cut depths are expected to be about 4 feet. Foundation loadings for this type of
construction are assumed to be relatively light and typical of the proposed type of
construction. The septic disposal system is proposed to be located to the north of the
proposed cabin.
If building conditions or foundation loadings are significantly different from those
described above, we should be notified to re-evaluate the recommendations presented in
this report.
Site Conditions: There are numerous cabins located on the property. The cabins consist
of one to two story log structures. The ground surface in the proposed building area is
relatively flat with a gentle slope down to the northwest. There is about 2 to 4 feet of
elevation difference across the proposed cabin site. A creek is located to the northeast of
the proposed cabin. Vegetation consists of scattered evergreen and aspen trees, grass and
weeds. Cobbles and boulders up to about 10 feet in size are exposed on the ground
surface.
Subsurface Conditions: The subsurface conditions at the site were evaluated by
excavating two exploratory pits in the building area and one profile pit in the septic
Parker 303-841-7119 • Colorado Springs 719-633-5562 9 Silverthome 970-468-1989
0 0
-2-
disposal area at the approximate locations shown on Figure 1. The logs of the pits are
presented on Figure 2. The subsoils encountered, below about 1'/2 feet of topsoil, consist
of relatively dense, slightly clayey silty sandy gravel with cobbles and boulders up to
about 8 feet in size to the pit depths of 6%2 feet. Results of gradation analyses performed
on samples of the gravels (minus 3 inch fraction) obtained from the pits are presented on
Figure 3. Atterberg limits testing indicates the matrix to be silty with low plasticity.
Groundwater was encountered in Pit 2 at a depth of 5 feet. No free water was
encountered in Pit I at the time of excavation and the soils were typically slightly moist to
moist.
Foundation Recommendations: Considering the subsoil conditions encountered in the
exploratory pits and the nature of the proposed construction, we recommend spread
footings placed on the undisturbed natural gravel soil designed for an allowable soil
bearing pressure of 2,500 psf for support of the proposed cabin. Footings should be a
minimum width of 16 inches for continuous walls and 2 feet for columns. Loose and
disturbed soils encountered at the foundation bearing level within the excavation should
be removed and the footing bearing level extended down to the undisturbed natural gravel
soils. Voids created by the removal of large rocks should be backfilled with compacted
sand and gravel or with concrete. Exterior footings should be provided with adequate
cover above their bearing elevations for frost protection. Placement of footings at least
42 inches below the exterior grade is recommended for this area. Continuous foundation
walls should be reinforced top and bottom to span local anomalies such as by assuming
an unsupported length of at least 10 feet. Foundation walls acting as retaining structures
should be designed to resist a lateral earth pressure based on an equivalent fluid unit
weight of at least 50 pcf for the on-site soil as backfill, excluding rock larger than about 6
inches.
Floor Slabs: Currently no floor slabs are proposed. However, there may be some
exterior slabs in the future. The natural on-site soils, exclusive of topsoil, are suitable to
support lightly loaded slab -on -grade construction. To reduce the effects of some
differential movement, floor slabs should be separated from all bearing walls and
columns with expansion joints which allow unrestrained vertical movement. Floor slab
control joints should be used to reduce damage due to shrinkage cracking. The
requirements for joint spacing and slab reinforcement should be established by the
designer based on experience and the intended slab use. A minimum 4 inch layer of sand
and gravel should be placed beneath slabs -on -grade as a leveling course. This material
should consist of minus 2 inch aggregate with less than 50% passing the No. 4 sieve and
less than 12% passing the No. 200 sieve.
All fill materials for support of floor slabs should be compacted to at least 95% of
maximum standard Proctor density at a moisture content near optimum. Required fill can
consist of the on-site soils devoid of vegetation, topsoil and oversized rock.
Surface Drainage: The following drainage precautions should be observed during
construction and maintained at all times after the cabin has been completed:
1) Inundation of the foundation excavations and underslab areas should be
avoided during construction.
Job No. 104 456-1
0
-3-
2) Exterior backfill should be adjusted to near optimum moisture and
compacted to at least 95% of the maximum standard Proctor density in
pavement and slab areas and to at least 90% of the maximum standard
Proctor density in landscape areas.
3) The ground surface surrounding the exterior of the building should be
sloped to drain away from the foundation in all directions. We
recommend a minimum slope of 6 inches in the first 10 feet in unpaved
areas and a minimum slope of 3 inches in the first 10 feet in pavement and
walkway areas.
4) Roof downspouts and drains should discharge well beyond the limits of all
backfill.
Percolation Testing: Percolation tests were conducted on October 13, 2004 to evaluate
the feasibility of infiltration septic disposal systems at the site. One profile pit and three
percolation holes were dug in two areas at the locations shown on Figure 1. The test
holes (nominal 12 inch diameter by 12 inch deep) were hand dug at the bottom of shallow
backhoe pits and were soaked with water one day prior to testing. The soils exposed in
the percolation holes are similar to those exposed in the Profile Pits shown on Figure 2
and consist of 1 to 1'/2 feet of topsoil overlying slightly clayey, silty sandy gravel with
cobbles and boulders to the pit depths of 8 feet. PVC and corrugated metal pipes were
installed in the pits to measure future water levels. The percolation test results are
presented in Table 1. The percolation test results indicate an infiltration rate between 13
and 36 minutes per inch with an average of 26 minutes per inch for Area 1. An
infiltration rate between 17 and 20 minutes per inch with an average of 18 minutes per
inch was indicated for the Area 2 testing. Based on the subsurface conditions
encountered and the percolation test results, the tested areas should be suitable for
conventional infiltration septic disposal systems. Pitkin County requires a professional
engineer design the infiltration septic disposal systems.
Limitations: This study has been conducted in accordance with generally accepted
geotechnical engineering principles and practices in this area at this time. We make no
warranty either express or implied. The conclusions and recommendations submitted in
this report are based upon the data obtained from the exploratory pits excavated at the
locations indicated on Figure 1, the proposed type of construction and our experience in
the area. Our services do not include determining the presence, prevention or possibility
of mold or other biological contaminants (MOBC) developing in the future. If the client
is concerned about MOBC, then a professional in this special field of practice should be
consulted. Our findings include interpolation and extrapolation of the subsurface
conditions identified at the exploratory pits and variations in the subsurface conditions
may not become evident until excavation is performed. If conditions encountered during
construction appear different from those described in this report, we should be notified at
once so re-evaluation of the recommendations may be made.
This report has been prepared for the exclusive use by our client for design purposes. We
are not responsible for technical interpretations by others of our information. As the
project evolves, we should provide continued consultation and field services during
construction to review and monitor the implementation of our recommendations, and to
Job No. 104 456-1
Gecliter�l
-4-
verify that the recommendations have been appropriately interpreted. Significant design
changes may require additional analysis or modifications to the recommendations
presented herein. We recommend on-site observation of excavations and foundation
bearing strata and testing of structural fill by a representative of the geotechnical
engineer.
If you have any questions or if we may be of further assistance, please let us know.
Respectfully Submitted,
Jordy Z. Adamson, Jr., P
Reviewed by:
Steven L. Pawlak, P.E.
J7.A/ksw
attachments Figure 1 — Location of Exploratory Pits and Percolation Test Holes
Figure 2 — Logs of Exploratory Pits
Figure 3 — Gradation Test Results
Table 1 — Percolation Test Results
cc: High Country Engineering — Attn: Greg Shaner
Job No. 104 456-1
1ti
BOUNDARIES
J18
PUMP /(PONT
W
HSEOI6 \\
EXISTING
CORRAL
EXISTING
1
STEPHENSON
PROPERTY
DIAMOND JOY
GUEST RANCH
POND
EXISTING /
CABIN ) QP
(TYPICAL)
12 LP -2
!/ p
® PROA
O NPIT 2 /
AREA 2
m Al
PIT I ❑6
Q I
AREA 1
P-3 P ^
P-1
3(POU
PIT 2 022
P OFILE
PIT 1 I
/ APPROXIMATE SCALE
1 = 140
HEPWORTH-PAWLAK LOCATION OF EXPLORATORY PITS AND Figu::1
104 456-1 GEOTECHNICAL, INC. PERCOLATION TEST HOLES
PIT 1 PIT
0
2
PROFILE
PIT 1 PROFILE
PIT 2
0
a..•:•
..
V
m'0.
I
5 I
t +4=41
.••u
_ +4=33
.•'a.
.o:.
'
,.'n• _
a -200-19
-200-23
•O�'
�• a
'•
.!A.
v
LL -21
LL -19
PI -2
PI -2
L 10 10
LEGEND:
rlTOPSOIL; sandy clay, slightly organic, firm, slightly moist, brown.
GRAVEL (GM); silty. sandy, slightly clayey, with cobbles and boulders up to about 8 feet in size,
medium dense to dense, slightly moist to moist, moist to wet below water in Pit 2, brown,
subrounded rock.
- Disturbed bulk sample.
Free water level in pit at the time of excavation.
Indicates 2" PVC pipe was installed in pit.
Indicates 12" corrugated metal pipe was installed in pit.
NOTES:
1. Exploratory pits were excavated on October 12, 2004 with a Caterpillar 315L trackhoe.
2.- Locations of exploratory pits were measured_approximately_by_pacing_from _feotures shown on the
site plan provided.
3. Elevations of exploratory pits were not measured and the logs of exploratory pits are drawn to depth.
4. The exploratory pit locations should be considered accurate only to the degree implied
by the method used.
5. The lines between materials shown on the exploratory pit logs represent the approximate boundaries
between material types and transitions may be gradual.
6. Water level readings shown on the logs were made at the time and under the conditions indicated.
Fluctuation in water level may occur with time.
7. Laboratory Testing Results:
+4 = Percent retained on the No. 4 sieve LL = Liquid Limit ( 9. )
—200 = Percent passing No. 200 sieve PI = Plasticity Index (% )
104 456-1I GEOTECHNICALAK I LOGS OF EXPLORATORY PITS I Figure 2
0 0
HEPWORTH-PAWLAK GEOTECHNICAL, INC.
TABLE 1
PERCOLATION TEST RESULTS
]OB NO. 104 456-1
Page 1 of 2
HOLE NO.
HOLE DEPTH
(INCHES)
LENGTH OF
INTERVAL
(MIN)
WATER
DEPTH AT
START OF
INTERVAL
INCHES
WATER
DEPTH AT
END OF
INTERVAL
INCHES
DROP IN
WATER
LEVEL
(INCHES)
AVERAGE
PERCOLATION
RATE
(MINJINCH)
P-1
(Area 1)
58
15
8
7
1
30
7
6
1
6
6
0
6
51/2
Y2
5 1/2
5
1/2
5
41/2
1/2
41/2
4
1/2
4
31/2
1/2
P-244
(Area 1)
15
Water added
Water added
71/4
5 1h
1 3/a
13
5 1/2
4
1 1/2
71/2
6 1/2
1
6 1/2
5
11/7.
5
4
1
71/2
6
11/2
6
5
1
5
4
1
P-3
(Area 1)
50
15
71/2
7
1/2
36
7
6 1/2
Y2
6 1/2
61/4
'/a
61/4
6
'/a
6
5 1/2
1/2
5 1/2
5 1/4
1/4
5 1/4
4 3/4
1/2
4 3/4
4 1/2
V2
Note: Percolation test holes were hand dug in the bottom of backhoe pits and soaked on
October 12, 2004. Percolation tests were conducted on October 13, 2004. The
average percolation rates were based on the last three readings of each test.
0 0
HEPWORTH-PAWLAK GEOTECHNICAL, INC.
TABLE 1
PERCOLATION TEST RESULTS
]OB NO. 104 456-1
Page 2 of 2
HOLE NO.
HOLE DEPTH
(INCHES)
LENGTH OF
INTERVAL
(MIN)
WATER
DEPTH AT
START OF
INTERVAL
INCHES
WATER
DEPTH AT
END OF
INTERVAL
INCHES
DROP IN
WATER
LEVEL
(INCHES)
AVERAGE
PERCOLATION
RATE
(MIN./INCH)
(Area 2)
46
15
Water added
9
71/2
1 1/2
20
71/2
61/2
1
61/2
5
1 1/2
5
4
1
8
7
1
7
6
1
6
51/4
3/4
5 1/4
41/2
3/4
P-2
(Area 2)
40
15
Water added
9
8
1
17
8
7
1
7
6
1
6
5 1/4
3/4
81/2
71/2
1
71/2
6 3/4
3/4
63/4
6
3/4
6
5
1
(Area 2)
42
15
Water added
10 1/2
9
1 1/2
17
9
8
1
8
7
1
7
61/2
1/2
61/2
5 3/4
3/4
5 3/4
5
3/4
10
9
1
9
8 '/a
3/4
Note: Percolation test holes were hand dug in the bottom of backhoe pits and soaked on
October 12, 2004. Percolation tests were conducted on October 13, 2004. The
average percolation rates were based on the last three readings of each test.
R
r-1
� s
DATE.
Sd5-
DRAYW BY.
A A�
SOLE
AS NOTED
LUST. ID S.
115005
REVMSIOILh
Tib SAD105
� ND.
03i -ZS -45
•
0
4/l/2005
CD
4/l/2005
0
r 1
LI
•
07/07/2003 16:07
97092 6
10
JUL-07-2003 00:11AM
FROM-DIVSWAT 9709458741 T-178
wRJ•5•Re-. 76
COL. ADO DIVISION OF WATER RESOUR A
"
818 Centennial Bldg., 1313 Sherman SL, Denver, Colorado 60203
PERMIT APPLICATION FORM
Application must
be complete where
I i.) A PERMIT TO USE GROUND WATER
applicable. Type or
( X) A PERMIT TO CONSTRUCT A WELL
print in BLACK
FOR: ( 11 A PERMIT TO INSTALL A PUMP
INK.Nooverstrike;
or erasures unless
( I REPLACEMENT FOR NO.
initialed.
i ) OTHER
WATER COURT CASE NO.
mailing address
NAME Voce R. Riley
STREET 26604 Frying Pan Road
CITY Meredith color#Ao 81642
ISmte) (ZIP)
TELEPHONE NO. 927-3222
(2) LOCATION OF PROPOSED WELL
county Pitkin Co.
NE Y. of the NE 7t Section 20
Twp. 8 S, Rng.. 83 -AL, 6 P.M
t N.51 tE.M
(3) WATER USE AND WELL DATA
Proposed maximum pumping rate (gpm) 30 9PM M2X-
Average annual amount of ground water
to be appropriated lacre-feet): 5. A.F/Yr-
Number of acres to be irrigated: None
Proposed total depth Ifeet): 130 Et.
Aquifer ground water is to be obtained from:
Owner's well designation
GROUND WATER TO BE USED FOR.
1 XI HOUSEHOLD USE ONLY • no irrlgatlon (0)
1 g) DOMESTIC (1) 1 1 INDUSTRIAL 161
I X) LIVESTOCK (2) 1 1 IRRIGATION (61
(XJCCOMMERCIAL (4) ( 1 MUNICIPAL (8)
I IOTHER
pETAIL THE USE ON BACK IN (11)
(4) DRILLER
Name lxonnta�n n. -Ula -.Q
Street 5062 li3 Road
Telephone No, 945-5148 Lic. No• 697
PAGE 19/28
P.003/004 F-752
RECEIVED
AW05'77
HATER RESOURCES •~
ke EMGIHEEA l'`
W%.
FOR OFFICE USE ONLY; DO NOT WRITE IN THIS COLUMN
Receipt No. S V3 S 1—
Basin
_Basin Dist.
CONDITIONS OF APPROVAL
This well shall be used in such a way as to cause
no material injury to existing water rights. The
issuance of the permit does not assure the applicant
tnat no injury will occur to another vested water
right or preclude another owner of a vested water
right from seeking relief in a civil court action.
1) A DECREE FOR THIS APPROPRIATION HJST BE
OBTAIM FROM THE DISTRICT COURT IN AND POR 4AT
DIV. NO. 5a STAT$ OF COLORADO, PRIOR TO TEE USE
OF THIS WELL, THIS APPROVAL IS SUBJECT TO THE
TERMS OF SAID DECREE.
2) A IITHOLOGIC LOG OF THIS WELL Si U BE PRE-
BIRED BY EITHER A COMPED= WATER WELL CONTFACT
OR A QUALTYIED GEOLOGIST.
3) THE PUMPING RAT? OF THIS WELL SHALL BE 7 T
TO 30 GPM OR THE ACTUAL YIELD OF THE AQ[TMR,
omcR VER IS LESS,
4) TOTALIZING FLOW METER MUST nE INSTALLED ON T
WELL DISCEARGE WHEN THE WATER IS PUT TO BENE-
FICIAL USE. DIVERSION RD20109 SFF.LL EE SLMtZTT
UPON REQUEBTs TO THE DIVISION OF WATER RESOUX�
APPLICATION APPROVED
PERMIT NUMBER 22899—
DATE ISSUED MOV 08 1977
EXPIRATI
ON
DATE NOV`1iI08 1978
7 '
I'7SA N EER)
I.D. S —,39 --COUNTY .
07/07/2003 16:07 970925 68
JUL-07-2003 0901AM FROIKIMATEA
PAGE 20/26
9709458741 • T-178 R.004/004 F-762
(5) 7HE LOCATION OF THE PROPOSED WELL and Nce area en
': whin the ureter Will be used must be indicated on the diagrarl below.
. Use the CENT ER. SECTION It section. 840 acres) for the well loeatiOn
y .
3•'� °' : p• •tI AME 5780 FIR
Now
%'�y'r' '»•�.('� pF,'�, `h}I'rM y? I•i':t~y�l� •'� ��'^Y;•••''-a "•'1
'.,• . , NWrtH SEGT10N Lai
147
-�Nottn. fit :: _ 'F _ _..{ . L':Lyy ; +
•: •�• • I • . .:.TMN•�Ci.w It:: '.' s : � •. x:9'1 •s i> ��'v,'�(�•k` .•.,'� t+.
aa�y-�y�%#+�I
�� :,, .f'{: •., �'�•'.{ �,ufrn�'(!'�t $,7 'tay�';'I•-r,'n'c �.tJ' i
(8) THE WILL MUST BE LOCATED BELOW ..
by disafrctn from section lines. ,
800 tt from North sea line
200h from—witf ant /
teC One
.i' . _ '• .. or weft) ..
,tOj '. I.DCK FILING •
SUBDIVISION
(7) TRACT Of_ WHL0 wcLL WILL eE
.LOCATED owner: Brutes R. Riley _
Ne. of IIOK'' Wal this be
*a only well an this tract?
(8) PROPOSEDC IN PROGRt
•� {,.~fon ' Oe ft to 1001 it
"` it /gry'•y ts. ft to
SOUTH SEG>;].. .. �, :� •.�M ".•.: �,t �a' tl • .,4'•'
'f ''•ttr:r�;•x't{.\t �_';'-<-... „1r, t•( `tom'YV�s.lr• 1,'{,'. in. frONl..�iG
• i .• V 1 ', '\•' 1 I•t:?i •„ X7''1: Y .'!?,ilk I• ,�i,�.�..,
.i n� . .1" �• t: �1 •'/•�:57i;. �A.�',.'"' f J•�(�,ti,.� 1�.A't1�..+, . .J
SS�n ^ \i~r'1-.Ji .�, •�/�' �•t- T 111:1m •il ,' .,'
�:`• A
•:. :m.' ) ; ;� .' EQ5REP WELLSgive distance
AM
s• :,.., .;.:•• ctas,� ':�'..;;. on• Insndplomtorplugging
•'7�.' 1 •.:�. `.1..^1,;:k(`T?r1",!'s'� r ,•1 l.. iti; t :r;: , . .
rale of the dlag�'am is 2 inrhes'�'1,'mlle;;',:•t•'!';• .:'I `�
•,L$ • •, r Each small l square represents
•w':. , y_` �- � WATER EWIVALEe1T5 TABLE (AOIYIdad :Flouml::
d to a,S"•'t• a !' An 3044wt coven t gas of lad t loot doW " :. - n: •• ' ,
I t eubirfoot per second Ids) ..'. 449 gallons oar minuto Itpml ..
• , ' A lamlly of 5 will rguirs soproslmetely 1 scrsfoot of water per VW. ••
. taerefoot...43S6e wbie feet:.. 325,900 Baltoes.
p0� .. '•,tt.
1,oepm pumped wntlnuoutly for one dw produ 4d2 earfeet.
`�.(Lp} LAND ON WHICH GROUND WATER WILL BE USED -I •, � •
Ownerts): "$nice Re Rilqz NO. of aclesw
61) DETAILED DPT
Fa'RIION of the use of ground water: Household use and domestic wells must indicate type.Of disposal
syttemtobeused.COmM1erOi61 iue8t r (Ful nno.t,. )w, clay ♦ th ���
lmath8 domeetio for ovua year arolatdt jiyggtgw�L 1 r at x 4F�c —
' - .-
(12) used on this land, including wells. Give Registration and Water Court Case Numbers.
'• ,r -;-:"`.%TSI'" ' •iJseti for Ipurpo�e) .'... .'` DescripiiGo of land on whirl, used: ..
Type:Or.irigftt- . .,
Surface Aero a-I/1Y4JsSA
Spring Comoera LIL divest ezdiiifa Same as aboga -
(13)THE APPLICANTS} STATES) .THAT THE INFORMATION SET FORTH HEREON IS h
":;c- TRULTHE'BEST••OFHYt/NOWLEDGE 'K • 'c::
:.,•-qtr 1- v~ '^•�-}•.•y P •n' -
_•/11�V: ,,.�.ry I f. q!� . ��, c,�l'cK 1nir�� ��V,'M17,�71'�''�J�e`Mvr'.a>.rG.. 4r-`v�.P- Y�,'rt f - ,•'�' 'y t,'
/�-� 4r'a.' +j� htl,rj �•� �1!�•G;�i1r?y?�:.'�: 7,
.
r"
IQy
VDIVIDUALSEWA('E DTSPOSAL SYSTEM PERMU
. I Connell Development Company (printed owner's name) accept the
responsibility for obtaining all soil information and other requirements of the
Environmental Health Department that are necessary' .to obtain an •Individual
Sewage Disposal System (ISDS) -permit, and know that a building permit will not be
issued until the ISDS permit has been issued. I recognize that I am submitting my
application for a building permit without completing the necessary field work to obtain a
permit to construct an ISDS.• I realize that I may incur additional expense in the form of
plan check, energy code, and zoning review fees if changes to my original plan are.
necessary. I recognize that, by entering the building.permit application process in this
fashion, I am taking a risk that night ultimately mean I cannot build on the property in
question, the dwelling might be smaller tha> originally designed, and that I.might have to
subunit an entirely new set of plans. I further accept the fact that by having to resubmit
plans' it may cause extended delays'to• issuance of the permit to construct.
This waiver,will not apply if the project has had a previous condition of approval by
-Pitkin County stating that an ISDS permit must be obtained prior to submitting plans to
the Building Department. If the applicant wants taapply for the "Waiver" anyway, the
applicant in= request that the County change the condition of approval previously
granted.
Building permit, plan review, energy code review, and zoning review fees are due at
permit submittal and may not b�refun4ed. .
OWNER
SIGNAT
OWNER DESIGNATED
REPRESENTATIVE:_
watcr.icds aiv.dm
�)J
'/K/0 J"
(OPTIONAL)
... _.. c..:..... en.�s c.•.....m N1611-1975 • P9ora 970.9205090 • F� 970.9205439
7 0 <�� WITH E Pi_k NT FILTER
1e 9
I
..-- EXISTING CABIN 13
rUNDER SEPARATE ISDS
7' 4"0 VG -
SE ® MIN
C9, CLEAN OUF"0 P
EXISTING CABIN 9 SEWER ®2%, /MiiKKff
UNDER SEPARATE ISZD
50' 4"0 PVC'
®2% MIN e.
u
9(STING SEPTIC T,%NK 14 40 PVC
REMOVED /SEWER 9�% MIN
- CL AN OUT 160 4' 0 PV
PVCA
® MIN
FS
T a
v2
CLEAN OUT
�X49' 4"0 PVC
SEWER ®2
j MINL -1 z
50' 4"0
SEWER ® 2%
EXIST
_ J
35 4'0 PVC
SEWER ® 2% MIN
SEWER ® 2% M
1000 G
NOSING
W2
=1"TAal A
- -99- ---
EXISTING MINOR TOPOGRAPHY
- -95-
EXISTING MAJOR TOPOGRAPHY
^00
�y vv
PROPOSED MINOR TOPOGRAPHY
Subsoil Drains,
PROPOSED MAJOR TOPOGRAPHY
I 1 ELEVATION 116 RELATIVE TO THE
Septic
875
EXISTING GRAVEL DRIVEWAY
SHOWN EXISTING CONTOURS
PROPOSED GRAVEL DRIVEWAY
Occupied
Piped or Lined
Intermittent
Course, Irrigation
EXISTING LEACHFIELD
Tank
EDGE OF DRIVEWAY
Suction
EXISTING CULVERT
Supply
ISDS SETBACK
IN FEET)
inch 30 ft.
PROPERTY BOUNDARY
DN-SERTIC TANK \
WITH EFFLUENT FILTERS
6' 4"0 PVC
62' 4'3„0 PVCSEWEi`® 2% MIN \
rr SEWER'.® 2% MIN \
I^ \ CLEAN OUT \
L5.3' 41ff
SEWS 7 4"ETN RMIN
114' 2'0 PVCI- --
DOSING- SEWER LIN
22', 40
SEWER 2% MIalf
N
� 20' SETBACK
FROM BUILDING %
CABIN V1 CLEAN 0 11
EX�3TING C' ABIN 6
DISTRIBUTION BOX <
5. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS TO
WITHIN ONE-HALF FOOT OF FINAL GRADE.
7. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG
AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED.
8, PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM ABSORPTION
FIELD AREA USING DRAINAGE SWALES AS NECESSARY,
9. SOILS AND PERCOLATION INFORMATION PROVIDED BY H.P GEOTECH, INC.,
JOB NO. 104 456, DATED JULY 29, 2004, AND JOB NO. 104 455-1 DATED
OCTOBER 20, 2004,
10. THIS DRAWING DOES NOT CONSTITUTE AN ISDS PERMIT. PERMIT MUST BE
OBTAINED FROM APPROPRIATE CITY OR COUNTY OFFICIALS.
ENGINEER MUST OBSERVE CONSTRUCTED SYSTEM BEFORE BACKFILL
11. THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH
OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS
OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM.
12. SITE PLAN INFORMATION PROVIDED BY THE CLIENT.
13. INSTALL BLUEBOARD INSULATION OVER SEWER PIPE WHEREVER DEPTH IS
LESS THAN 5.0 FEET.
14. THE ENGINEER SHALL BE CONTACTED FOR SITE INSPECTION PRIOR TO
BACKFILLING OF SYSTEM COMPONENTS.
15. THIS SYSTEM IS DESIGNED FOR TYPICAL DOMESTIC WASTES ONLY. HOME
OWNER IS RESPONSIBLE FOR TIGHT PLUMBING FIXTURES. I.E. HISSING
TOILETS AND RUNNING WATER 15 NOT ACCEPTABLE AND MAY OVERLOAD THE
GRAPHIC SCALE
I \ I INFILTRATION BED
Potable
Dwelling
BOTTOM OF INFILTRATORS TO
Subsoil Drains,
30 0 15 30 60 120
I 1 ELEVATION 116 RELATIVE TO THE
Septic
875
Wells,
SHOWN EXISTING CONTOURS
Water
Occupied
Piped or Lined
Intermittent
Course, Irrigation
Gulches
Tank
INSPECTION WELL (TYP) J
Suction
Supply
Supply
Building
IN FEET)
inch 30 ft.
Irrigation Lateral
Ditch or Stream
�.� 1 =
sufficient size to accommodate the pipe shall be drilled in the lowermost section of the ridged cap so that the conveyance pipe rests on the bottom of the encasenent
Lines
Line
Cistern
W,q44,
TO ALLOW FOR CONSTRUCTABILITY.
(3) Add 8 feet additional distance for each 100 gallons per day of design flow over 1000 gallons per day as specified in the table, unless it can be demonstrated by a
1.
ALL CONSTRUCTION SHALL BEGIN ACCORDANCE WITH THE PITKIN COUNTY
registered Professionol Engiaeeror Geologist thatamechmical or natuml barrier will prevent contami�tiom
Dispersal System Utilizing
REGULATIONS OF INDIVIDUAL SEWAGE DISPOSAL SYSTEMS, EVEN THOUGH
1.
ABSORPTION LATERALS SHALL NOT EXCEED 100 -FEET IN LENGTH.
ALL SUCH REQUIREMENTS ARE NOT SPECIFICALLY NOTED ON THE DRAWINGS.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUCH SPECIFIC DETAILS AS
2.
THE BOTTOM OF ABSORPTION BED SHALL BE LEVEL.
ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS.
3.
DRAINAGE SWALES ARE PROVIDED ABOVE AND AROUND ABSORPTION BED, AS 2.
EXAMPLE BELOW: QEF TABLE FOR CAICULATION SUMMARY
125
NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING ABSORPTION AREA.
4 BEDROOMS (SEASONAL USE CABIN) 2 PERSONS/BEDROOM * 50
:n -'
=
GALLONS/PERSON/DAY IS: 400 GPD AVERAGE DAILY FLOW
4.
INSTALL INFILTRATOR IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS,
DESIGN FLOW = 7.75 +AVERAGE = 700 GPD (0)
5.
NO EXCAVATION OF ABSORPTION FIELD IS DONE DURING WET WEATHER
Q * 1 DAY/24 HRS * 30 HRS = 875 GPD
AND USE OF RUBBER TIRE VEHICLES OVER ABSORPTION AREA IS PROHIBITED
INSTALL ONE 1,000 -GALLON TANK WITH BAFFLE
f
.**INSTALL BIO -FILTER IN SEPTIC TANK OUTLET***
6.
BOULDERS EXISTING WITHIN THE ABSORPTION BED SHALL BE EXCAVATED AND
A = Q FLOW
21
BACKFILL SHALL CONSIST OF ONSITE SELECT OR PIT -RUN MATERIAL,
.rF t=MAXIMUM
--5- =PERCOLATION RATE = 26 min./in.*
7.
EQUILATERAL DISTRIBUTION SHALL BE USED WITHIN ABSORPTION BED.
2275 42-6
(3)
(4X2)
= 2320
USE QUICK 4 STANDARD CHAMBER INFILTRATOR UNITS IN BED CONFIGURATION:
(3)
50
(3)
25
70% REDUCTION (2275 SF * 0.70) 0 9.87 S.F./UNIT, 165 UNITS REQUIRED.
Bed, Sand Filter, Subsurface
- 3.
CLEAN OUTS ARE REQUIRED AT ALL BENDS AND AT LEAST EVERY 100
25
20
FEET ALONG THE HOUSE SEWER.
10
4.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL
.
WATER TIGHT COMPONENTS, PRIOR TO THE ABSORPTION AREA,
TABLEII
TABLE OF MINIMUM HORIZONTAL DISTANCES IN FEET BETWEEN COMPONENTS OF A SEWAGE DISPOSAL SYSTEM 5.
TOPSOIL COVER MAY BE VARIED (WITH 1 FOOT MINIMUM) TO ALLOW
INSTALLED AFTER NOVEMBER 15, 1973 AND PERTINENT PHYSICAL FEATURES
LANDSCAPING.
5. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS TO
WITHIN ONE-HALF FOOT OF FINAL GRADE.
7. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG
AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED.
8, PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM ABSORPTION
FIELD AREA USING DRAINAGE SWALES AS NECESSARY,
9. SOILS AND PERCOLATION INFORMATION PROVIDED BY H.P GEOTECH, INC.,
JOB NO. 104 456, DATED JULY 29, 2004, AND JOB NO. 104 455-1 DATED
OCTOBER 20, 2004,
10. THIS DRAWING DOES NOT CONSTITUTE AN ISDS PERMIT. PERMIT MUST BE
OBTAINED FROM APPROPRIATE CITY OR COUNTY OFFICIALS.
ENGINEER MUST OBSERVE CONSTRUCTED SYSTEM BEFORE BACKFILL
11. THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH
OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS
OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM.
12. SITE PLAN INFORMATION PROVIDED BY THE CLIENT.
13. INSTALL BLUEBOARD INSULATION OVER SEWER PIPE WHEREVER DEPTH IS
LESS THAN 5.0 FEET.
14. THE ENGINEER SHALL BE CONTACTED FOR SITE INSPECTION PRIOR TO
BACKFILLING OF SYSTEM COMPONENTS.
15. THIS SYSTEM IS DESIGNED FOR TYPICAL DOMESTIC WASTES ONLY. HOME
OWNER IS RESPONSIBLE FOR TIGHT PLUMBING FIXTURES. I.E. HISSING
TOILETS AND RUNNING WATER 15 NOT ACCEPTABLE AND MAY OVERLOAD THE
Spring,
Potable
Potable
Dwelling
Property Lines,
Subsoil Drains,
Lake, Water
Dry
Septic
875
Wells,
Water
Water
Occupied
Piped or Lined
Intermittent
Course, Irrigation
Gulches
Tank
SHALL BE FILLED IN OR REMOVED TO COMPLETE TANK ABANDONMENT,
Suction
Supply
Supply
Building
Irrigation Ditch
Irrigation Lateral
Ditch or Stream
sufficient size to accommodate the pipe shall be drilled in the lowermost section of the ridged cap so that the conveyance pipe rests on the bottom of the encasenent
Lines
Line
Cistern
W,q44,
TO ALLOW FOR CONSTRUCTABILITY.
(3) Add 8 feet additional distance for each 100 gallons per day of design flow over 1000 gallons per day as specified in the table, unless it can be demonstrated by a
21.
THIS SYSTEM IS DESIGNED AS AN INFILTRATION BED UTILIZING A DOSING PUMP
registered Professionol Engiaeeror Geologist thatamechmical or natuml barrier will prevent contami�tiom
Dispersal System Utilizing
(3)
(4X2)
QUICK 4 INFILTRATOR UNITS. THE INFILTRATOR UNITS SHALL BE CONNECTED WITH
(3)
25
(3)
10
10
Aerosol Methods
too
10
50
125
10
0
:n -'
w
Seepage Pit or Slit Trench
(3)
(4X2)
(3)
f
100
!0
23
20
21
10
so
!0
25
Absorption Trench, Seepage
(3)
(4X2)
(3)
50
(3)
25
i
Bed, Sand Filter, Subsurface
100
25
25
20
10
10
Dispersal System, or Drywttll
Unlined Sand Filter in Soil
(4X2)
25
IS
10
With a Percolation Rate
100
25
25
IS
10
10
Slower than 60 Minutes per
Inch
Unlined or Partially Lined
25
IS
;0
Evapotranspiration System,
loo
(4X2)
25
15
10
10
Wastewater Pond, or Surface
25
Disposal System Other than
le
`
-
Aerosol
a
,
Lined Sand Filter
60
(4X2)
25
IS
10
!0
25
10
5
i
la
1
�
�v
Lined Evapotranspiration
(4X2)
25
15
10
10
25
10
5
Field or Lined Wastewater
60
10
5
sir,
Pond
_
Pi[Privy ar Vault Privy
(4)2)
50
10
25
15
10
10
25
10
-
Sep[icTanks,Treatment
(2)
(4X2)
(1)
Plants, Dosing Tanks, Vaults
50
10
25
5
10
IO
50
10
-
SuildingSeweror
(2)(4)
(4X2)
(4)
(2)(4)
(4)
(2X4)
(2X4)
Effluent Lines
50
10
25
0
10
10
50
10
-
5. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS TO
WITHIN ONE-HALF FOOT OF FINAL GRADE.
7. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG
AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED.
8, PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM ABSORPTION
FIELD AREA USING DRAINAGE SWALES AS NECESSARY,
9. SOILS AND PERCOLATION INFORMATION PROVIDED BY H.P GEOTECH, INC.,
JOB NO. 104 456, DATED JULY 29, 2004, AND JOB NO. 104 455-1 DATED
OCTOBER 20, 2004,
10. THIS DRAWING DOES NOT CONSTITUTE AN ISDS PERMIT. PERMIT MUST BE
OBTAINED FROM APPROPRIATE CITY OR COUNTY OFFICIALS.
ENGINEER MUST OBSERVE CONSTRUCTED SYSTEM BEFORE BACKFILL
11. THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH
OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS
OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM.
12. SITE PLAN INFORMATION PROVIDED BY THE CLIENT.
13. INSTALL BLUEBOARD INSULATION OVER SEWER PIPE WHEREVER DEPTH IS
LESS THAN 5.0 FEET.
14. THE ENGINEER SHALL BE CONTACTED FOR SITE INSPECTION PRIOR TO
BACKFILLING OF SYSTEM COMPONENTS.
15. THIS SYSTEM IS DESIGNED FOR TYPICAL DOMESTIC WASTES ONLY. HOME
OWNER IS RESPONSIBLE FOR TIGHT PLUMBING FIXTURES. I.E. HISSING
TOILETS AND RUNNING WATER 15 NOT ACCEPTABLE AND MAY OVERLOAD THE
19' 4"0 PVC,_ 172' PROPOSED SEPTIC \
SEWER ®2% MIN ZONE OF INFLUENCE
f. v
1 122' SETBACK FOR WATERCOURSE
PVC LINER PROVIDED \
TO MEET SETBACK
� °' i.
_ PERCOLATION 4 7
TEST HOLE (TYP) \\ \\
' 100' 400 PVC \�\
SEWER ® 2% MIN
i., u
X43 OF 1 t I
WIN INE }
CLEAN OUT \ { F 1
/ TER UNE I I
/ ) _ / I
ERE f CABIN 5
r
RE /(TED -
/ I / 7 10' ISDS S(TBACK
PROPOSED 'HOUSE /f 1 TO PROPE7TYINE
�//
XMANIFOLD PIPING \ _ PRI)PERTY LINE I
10 MIL PVC LINER
INSTALL MINIMUM 3' 20 SE ACK
BELOW BED ELEVATION FROM -B SING
TO TOP OF INFILTRATOR.
TO FORCE INFILTRATION \ I
BELOW STREAM ELEVATION
WITHIN SETBACK. SEE NOTE 2. ( �/
REMOVABLE PVC CAP -
INSTALL MARKER IF CAI
IS TO BE BURIED
FINISH GRADE
4" COUPLING
4" SEWER LINE
4" RISER
4" 45' SWEEP BEND
_A
4° x 4" x 4"---//
PVC WYE
CLEAN OUT
ASSEMBLY
SEWER CLEAN OUT DETAIL
N. T. S.
REMOVABLE CAP
4 - 1/2" VENT HOLES
4" 0
SOLID PIPE
SIDX,11�\/RO�EGHENED
COUPLING.
0
12" �% 0
0
36"
/CUT HOLE IN TOP OF
/ INFILTRATOR UNIT FOR
INSTALLATION OF INSPECTION
WELL PIPE
/�%\ MIN, 1'
PROPOSED
BEDROOMS
SYSTEM.
NOTE: The minimum distances shown above shall be maintained between the system components and the physical features described. Where soil, geological or other woditions
16.
HIGH COUNTRY ENGINEERING RECOMMENDS CONCRETE SEPTIC TANKS
warrant, greater distances may be required by the local board of health or by the Water Quality Control Commission pursuant to CR5.25.8-206 in accordance with the authority
4
OR EQUIVALENT.
prescribed by law and rules and regulations implemental of said section. Components which are not watertight should not extend into areas of the root system of nearby, trues. For
875
Ct
repair or upgrading of existing systems where the size of lot precludes adherence to these distances, repaired facility shall not be closer to water supply components than du
17.
THE ISDS SHALL BE LOCATED MORE THAN 172' FROM EXISTING WELLS.
existing futilities.
78.
ALL EXISTING SEPTIC TANKS CURRENTLY PROVIDING SERVICE TO THESE CABINS
(1) Distance shown shall not apply to treatment plants oreffluent lines where recycling ispermitted.
13
SHALL BE FILLED IN OR REMOVED TO COMPLETE TANK ABANDONMENT,
(2) Crossings or encroachments maybe permitted at the points as noted above provided that the water conveyance pipe is roomed for a minimum distance often(10)feet
19
ALL EXISTING LEACH FIELDS CURRENTLY PROVIDING SERVICE TO THESE CABINS
on each side of the crossing. A length of pipe shall be used with a minimum Schedule 40 rating of sufficient diameter to easily slide over and completely etas, the
(CISTERN) AT 8 DOSES PER DAY
SHALL BE ABANDONED.
water conveyance. Ridged end caps of at least Schedule 40 rating must be glued or secured in a watertight fashion to the ends of the encasement pipe, Ahole of
sufficient size to accommodate the pipe shall be drilled in the lowermost section of the ridged cap so that the conveyance pipe rests on the bottom of the encasenent
20
ALL WATERLINE SLEEVES SHALL BE SCHEDULE 40 PVC PIPE OF SUFFICIENT SIZE
pipe. The area in which the pipe posses through the endcaps shall be sealed with an approved underground sealant compatible with the piping used.
W,q44,
TO ALLOW FOR CONSTRUCTABILITY.
(3) Add 8 feet additional distance for each 100 gallons per day of design flow over 1000 gallons per day as specified in the table, unless it can be demonstrated by a
21.
THIS SYSTEM IS DESIGNED AS AN INFILTRATION BED UTILIZING A DOSING PUMP
registered Professionol Engiaeeror Geologist thatamechmical or natuml barrier will prevent contami�tiom
$ET TO DOSE 8 TIMES PER DAY TD THE INFILTRATION BED CONSISTING OF 165
(4) Encroochmcntsmaybepermittedprovidedthewalerarwastewalereanveyancepipeisencasedasin(2)above,specificdintheuble.
QUICK 4 INFILTRATOR UNITS. THE INFILTRATOR UNITS SHALL BE CONNECTED WITH
MANIFOLD PIPING AT EACH END.
19' 4"0 PVC,_ 172' PROPOSED SEPTIC \
SEWER ®2% MIN ZONE OF INFLUENCE
f. v
1 122' SETBACK FOR WATERCOURSE
PVC LINER PROVIDED \
TO MEET SETBACK
� °' i.
_ PERCOLATION 4 7
TEST HOLE (TYP) \\ \\
' 100' 400 PVC \�\
SEWER ® 2% MIN
i., u
X43 OF 1 t I
WIN INE }
CLEAN OUT \ { F 1
/ TER UNE I I
/ ) _ / I
ERE f CABIN 5
r
RE /(TED -
/ I / 7 10' ISDS S(TBACK
PROPOSED 'HOUSE /f 1 TO PROPE7TYINE
�//
XMANIFOLD PIPING \ _ PRI)PERTY LINE I
10 MIL PVC LINER
INSTALL MINIMUM 3' 20 SE ACK
BELOW BED ELEVATION FROM -B SING
TO TOP OF INFILTRATOR.
TO FORCE INFILTRATION \ I
BELOW STREAM ELEVATION
WITHIN SETBACK. SEE NOTE 2. ( �/
REMOVABLE PVC CAP -
INSTALL MARKER IF CAI
IS TO BE BURIED
FINISH GRADE
4" COUPLING
4" SEWER LINE
4" RISER
4" 45' SWEEP BEND
_A
4° x 4" x 4"---//
PVC WYE
CLEAN OUT
ASSEMBLY
SEWER CLEAN OUT DETAIL
N. T. S.
REMOVABLE CAP
4 - 1/2" VENT HOLES
4" 0
SOLID PIPE
SIDX,11�\/RO�EGHENED
COUPLING.
0
12" �% 0
0
36"
/CUT HOLE IN TOP OF
/ INFILTRATOR UNIT FOR
INSTALLATION OF INSPECTION
WELL PIPE
/�%\ MIN, 1'
SECTIONS 20 & 21, TOWNSHIP 8 S, RANGE 83 W. 6TH P.M.
Y ICINffY MAP
SCALE 1' a 2000'
4" X 4"-+
TREATED ELEC. JCT. BOX
POST
RISER(S) TO
GROUND SURFACE
CAULK/SEAL WELL
INLET
a.
° Z "ALARM'-'
N
TANK
PROPOSED
BEDROOMS
AVERAGE
FLOW d
PEAK FLOW gpd)
1.75 PEAK
fs
TANK SIZE
GALLONS
1
4
400
700
875
Ct
2
9
900
1575
1969
2000
TOTAL
13
1300
-fix � -'. s A'R� .�• ,.
2844
. ' '
� �
(CISTERN) AT 8 DOSES PER DAY
�;t(„?
W,q44,
T,huFir,4vv1)1n a"
iN"
:n -'
w
;; n,•
"
WE
ti
v
le
`
a
,
4
i
1
�
�v
� t, 41
�
'•
-sem
5
sir,
_
5
is
SECTIONS 20 & 21, TOWNSHIP 8 S, RANGE 83 W. 6TH P.M.
Y ICINffY MAP
SCALE 1' a 2000'
4" X 4"-+
TREATED ELEC. JCT. BOX
POST
RISER(S) TO
GROUND SURFACE
CAULK/SEAL WELL
INLET
a.
° Z "ALARM'-'
N
TANK
PROPOSED
BEDROOMS
AVERAGE
FLOW d
PEAK FLOW gpd)
1.75 PEAK
TANK STORAGE
30 HR d
TANK SIZE
GALLONS
1
4
400
700
875
1000
2
9
900
1575
1969
2000
TOTAL
13
1300
2275
2844
1
'ON
WEIGHT
° OFF"-
ail ro
r..
2" AIR VENT
2" FEEDER LINE TO
FIELD, SLOPED AT
1/8" PER FT, MIN.
SHALL DRAIN BACK
TO TANK AFTER
EACH PUMP CYCLE.
QUICK DISCONNECT
OR UNION
COIL AND TIE AN
ADDITIONAL 10' OF
WIRE FOR PUMP
REMOVAL
SUBMERSIBLE WASTEWATER PUMP
SET PUMP APPROX.
8" OFF FLOOR
CABIN
PROPOSED
BEDROOMS
TANK
NUMBER
C4
1
1
NOTESe
+1.SSWIITCHES
2
2
C7
2
2
CIO
MERCURY FLOAT TYPE.
2
C11
2
2-
2
2. FLOAT SWITCH DIMENSIONS ARE BASED ON A COPELAND 1000 GAL. TANK.
2
PRH 1
3
1
(CISTERN) AT 8 DOSES PER DAY
CABIN
PROPOSED
BEDROOMS
TANK
NUMBER
C4
1
1
C6
2
2
C7
2
2
CIO
2
2
C11
2
2-
2
1
2
PRH 1
3
1
3, DOSING TANK SHALL BE OF WATERTIGHT CONSTRUCTION,
4, ALARM SHALL BE BOTH AUDIBLE AND VISIBLE, LOCATED WITHIN
THE HOUSE AND ON A CIRCUIT SEPARATE FROM THE PUMP.
5, PUMP SHALL BE CAPABLE OF AT LEAST 30 GPM ® 7 FT. OF HEAD.
(ELEVATION DIFFERENCE AND PIPE LENGTHS SHALL BE FIELD MEASURED BY
CONTRACTOR AND REFERRED TO ENGINEER FOR VERIFICATION OF PUMP PARAMETERS.)
6. OTHER DOSING TANK ARRANGEMENTS ARE AVAILABLE IF APPROVED BY PITKIN COUNTY.
DOSING TANK ARRANGEMENT
N,TS
NOTES:
1, THE ACTUAL LOCATION OF THE HOUSE (PRH1) WILL BE ADJUSTED AS
NECESSARY TO MEET BUILDING SETBACK REQUIREMENTS AS DETERMINED BY THE
VARIANCE APPROVED ON JUNE 21, 2005. ALL ISDS RELATED SETBACKS WILL
BE MET IN ACCORDANCE TO PITKIN COUNTY AND CDPHE REQUIREMENTS.
2. THE REQUIRED SETBACK DISTANCE BETWEEN THE ISDS INFILTRATION BED
AND THE EXISTING STREAM TO THE EAST IS NOT ENTIRELY MET. HOWEVER,
SURFACE FLOW WITHIN THE ISDS FIELD FLOWS AWAY FROM THE EXISTING
CHANNEL. ALSO, THE BOTTOM OF THE INFILTRATION BED SHALL BE INSTALLED
AT AN ELEVATION SUCH THAT THE BOTTOM OF THE INFILTRATORS IS BELOW
THE STREAM CHANNEL WITHIN THE REQUIRED SETBACK. IN AREAS WHERE THE
INFILTRATION BED IS NOT BELOW THE CHANNEL WITHIN THE SETBACK AREA, A
PVC LINER SHALL BE INSTALLED ALONG THE SIDE OF THE BED TO FORCE
INFILTRATION DOWNWARD TO AN ELEVATION BELOW THE STREAM CHANNEL PRIOR
TO ALLOWING LATERAL MOVEMENT OF THE EFFLUENT.
U
O >
CO
K Z
N
ZoNZ 0
( �? N
-im o n8p z
SZ Co 5
U�
J
0
Z
S0
W�
J
IA M
U)
4 1n
7 N
N =,
U
0
Z V0 CD
0
v0 IA Oto
IN
a
ln�
109 0 O
WjI 5 0 9 i
ZN U
77 y, W IL t9
amt
Wd' LqWU
W W
✓� O
a Z
GZ VZ
Z wo
W IL 4 IL
0 M
V
jx
V
x
EXISTING GROUND
4" 0 PERFORATED PIPE
INSPECTION WELL DETAIL
N.T.S.
NATURAL GROUND
NATURAL BACKFILL
r-12" MIN, COVER
TYPICAL CROSS SECTION
\.T.S,
INFILTRATOR UNIT
RECORD DRAWING
NOVEMBER 28, 2005
PROJECT NO.
2041709.00
0551
ISDS
FRYING PAN RIVER
STEPHENS❑N PROPERTY
M
N
FRYING PAN RIVER
GRAPHIC SCALE
60 0 30 60 120
/ II 61
r
ZONE OF INFLUENCE / EXISTING OVERHEAD I I
PROPOSE -LEACH FIELD 93 - POWER LINE I I
LOG-) / POWER POLE (TYP) E
OND
_ ._.
-�
\O ( ) G LEACH FIELD ROCK 1 Of 61
ZONE OF INFLUENCE I
� = EXISTING / I
,-Jo
_.. R100.00 i \
PROPOSED ___,.
LEACH FIELD #3 "'" / \ \/ \
61
TRENCH SYSTEM o / \ /� \ \\ R116.00 J Of �/ I '
IN SERIES _ _ `_4
"""�� EXISTING O ERHEAD
-- POWER LINE S A Oe )
- r
°o
_
90
PROPOSED
POND
w 'PROPOSED Fes- TA
NK #4
c .SEPTA -TANK #J — f ::__ �� .- FROM SETLDING� 1000 GALLONS \
/\ CORRAL ."-_ -- .,._I / 1000 GALLON8 VS NG'LEAC�H IEL�. F 0 U I� PROPOSED
' / r EXISTING SHED LEACH FIELD #2
VST
PRO"7' 25 X T N SYSTEM N
— /! H
OR� MEETS MINIMUM SETBACK
1 OCATED
REQUIREMENTS TO BUILDING
\ AND SEPTIC TANK
PROPOSED
SETBACK FROM w d / RELOCATE ROAD \\ 500 GALLON - -
/ PROPERTY UNE > {' __-\ ...,Y.,. ,,..� - S
_ PONS TO AVOIDiNT£RFERANCE ,
(10') - f _ -_WITH PROPOSED ISDS
1
R220.00
PROPOSED
/ LEACH FIELD g2 / �.. GONG PAD
Gfi F
TREN SYSTEM IN SERI S -- � `
M MINIMM SETBACK
RElyREMENTS f0 BUILD _ \
SHED
i y* A
ND SEPTIrC I KXIS'T_i.N.�G�W�AfiEli-LIN
.._
!-/-
- EXISTING
>�
WATERLINEJUNCTION01 (TYP) )
20'. SETBACK
EXISTING `FROM BUILDING
STORAGE Q&ARAPROPOSED EX -
SEPTIC TANK #2
s
gLL
ODG_ \`, ` 1 �" // J/// TINNGWATERLINE
\- - EXISTING/1`j„�.ss
- / ASPEN GROV y
/ I
BASE ROPE TOW \- " "
J1p
i ��. .__ /� \
1p
EXISTING WELL 3-- x
MEETS MINIMUM SETBACK REQUIRMENTS ¢
TO SEPTIC TANK 50'=
TO LEACHFIELD 100'
SETBACK FROM
C15\
PROPERTY LINE V'
PROPOSED /
_ SEPTIC TANK 5 _
1000 GALLO S i � 1—
BELL \
BUILDTN G -17-,,
�V CORAL B
r.
1
20' SETBA
FROM I BUILDING
3 R100.00
C4%
XISTING V _
LEACH FIEELD
TO -BE ABANDONED",'
\/ LEACH FIELD 04 —I A \f+ S1 PTIC TANK #7
20' SETBACK , \� TRENCH SYSTEM/ 000 GALLONS PROPO ED
FROM BUILDING IN SERIES R100.00 U. S. FOREST SERVICE \ 6' SETBACK SEPTICTANK #/
} FROM SEPTIC TANK 1000 G LLONN
PROPOSED
ZONE OF INFLUENCE EXISTING WATERLII� LEACH FIELD #1 20' SETBACK\
LEACH FIELD #4 JUNCTION BOX (TYP) ,,�RENC N SSYSTEM ERIES FROM LG
(100') �} EXISTING WATERLINE __QL SETBACK
FROM SEPTIC TANK
( IN FEET )
1 inch = 60 ft.
OF INFLUENCE
FIELD #2
50' ISDS SETBACK
FROM WATERCOURSE
APPROXIMATE LOCATION OF
EXISTING CREEK CHANNEL
TO BE VERIFIED
ZONE OF INFLUENCE
LEACH FIELD #1
\ (100')
RELOCATE ROAD TO
AVOID PROPOSED ISDS
AND HOUSE
ISETBACK FROM
PROPERTY LINE
(10')
/ PROPERTY LINE
240
IMM
y4
GA
ilk
i
NOTES:
1. OPTION A IS FOR FULL BUILD OUT. FULL BUILD OUT
CONSISTS OF 2 NEW 3 BEDROOM HOUSES AND EXPANSION
OF 3 ADDITIONAL BEDROOMS IN CABINS 6, 7, & 9.
2. AREA OF OVERLAP OF THE ZONE OF INFLUENCE FOR
LEACH FIELD 1 AND 2 IS APPROXIMATELY 826 SF WITH A
MAXIMUM OVERLAP DISTANCE OF 10 FT.
3. ALL EXISTING SEPTIC TANKS WILL BE REMOVED OR
FILLED EXCEPT FOR THE TANK SERVING THE LODGE. THIS
TANK WILL REMAIN IN SERVICE WITH CURRENT
CONTRIBUTING FLOWS,
4. ALL EXISTING LEACH FIELDS WILL BE ABANDONED
EXCEPT FOR THE LEACH FIELD SERVING THE LODGE. THIS
LEACH FIELD WILL NOT BE DISTURBED.
5, THE SETBACK FOR THE EXISTING LODGE ISDS IS
ESTABLISHED BASED ON THE ASSUMPTION THAT THE
EXISTING LODGE SEPTIC TANK IS AT FULL CAPACITY BUT
NOT UNDER SIZED AT 1500 GALLONS. THIS CORRELATES
TO A DESIGN FLOW OF 1200 GPM AND A SETBACK
REQUIREMENT OF 116 FT.
6. ALL WATERLINE CROSSINGS AND AREAS WHERE THE
WATERLINE INFRINGES ON ISDS SETBACK REQUIREMENTS
WILL BE SLEEVED IN ACCORDANCE WITH PITKIN COUNTY
AND COLORADO DEPARTMENT OF PUBLIC HEALTH
REGULATIONS,
CABIN
TANK
DRAWING
ID
EXISTING PROPOSED
NO. BEDROOMS N0. BEDROOMS
TO TANK
CABIN
1
Cl
1
1
4
CABIN
2
C2
2
2
3
CABIN
3
C3
2
2
3
CABIN
4
C4
1
1
3
CABIN
5
RLC5
1
1
3
CABIN
6
C6
1
2
7
CABIN
7
C7
1
1 2
2
CABIN
8
C81
EXISTING 1
1
4
CABIN
9
C9
1
2
2
CABIN
10
Ol0
2
1 2
2
CABIN
11
C11
2
2
7
CABIN
12
C12
1
1
2
CABIN
13
C13
2
2
2
CABIN
15
C15
2
2
5
LODGE
LODGE
LODGE
LODGE
7
3 BED
HOUSE
PRH1
0
3
1
3 BED
HOUSEI
PRH2
0
3
6
SEPTIC
TANK
NO. BEDROOMS
CONTRIBUTING
REQUIRED
TANK CAPACITY4
TANK
CAPACITY
TANK #1
NUMBER
OF UNITS
3
656 GAL
1000
GAL
TANK #2
IN
9
1969 GAL
2000
GAL
TANK #3
2 TANK 2, 3, 4
6
1313 GAL
1500
GAL
TANK #4
LEACH
2
438 GAL
1000
GAL
TANK #5
34
2
438 GAL
1000
GAL
TANK
6**
3
984 GAL
1000
GAL
TANK7
Z
4
875 GAL
1000
GAL
TANK
8***
LODGE
EXISTING 1
1500
GAL
" EACH BEDROOM ACCOUNTS FOR 50 GPDPP, 2 PEOPLE PER BEDROOM
INCLUDES 1,75 PEAK FACTOR AND 30 HR DETENTION
** SIZED PER RESIDENCE REQUIREMENTS, 75 GPDPP
EXISTING TANK WILL REMAIN IN SERVICE
LEACH
FIELD
CONTRIBUTING
SEPTIC TANK
PER LA
RATE
ON
I REQUIRED AREA I
OF LEACH FIELD I
NUMBER
OF UNITS
ZONE OF
INFLUENCE
LEACH
FIELD
#1 TANK 1 7
26MIN
IN
625 SF
64
100
LEACH
FIELD
2 TANK 2, 3, 4
18 MIN
IN
1262 SF
128
220
LEACH
FIELD
#3 TANK #6
1 18 MIN
IN
1 334 SF 1
34
1 100'
LEACH
FIELD
#4 TANK #5
1 30 MIN
IN*
1 192 SF 1
20
1 100'
" ASSUMED PERCOLOATION RATE. BASED ON PERCOLATION TESTS WITHIN THE
PROPERTY AND THE EXISTING FIELD AND THE EXISTING CONTRIBUTING TANK
1. REQUIRED AREA OF INFILTRATOR UNITS INCLUDES 50% REDUCTION FOR
TRENCH SYSTEM
2. THE NUMBER OF INFITRATOR UNITS IS BASED ON QUICK 4 STANDARD
INFILTRATORS WITH AN EFFECTIVE AREA OF 9.87 SF PER UNIT
ooh
�(7)o
Eo
z�NZ
:l°ao
PL
LI c
Q'z OD
UU '
O
U
N
n
z
CD
.r
U
U
uO~
OU)
Z
pt
za
aN
a
-jm
ZM
tom
Tri
wm
09
OM
N
C
W
Z
vq �
� V
TIL
W IL z
Z�
a
:to I
W
Z
I--
c z
�z
Z
W(L
as
0
V
Z
r�
V
1T�1
FSI
/i♦
Op Uz
Un Z
wLL �O
a 0 F.
Q
Z
O 0 0
�_'7W a
�0 Dtn 0
zx 00.
o0. as
0
PROJECT NO.
2041709.00
0913
2