Loading...
HomeMy WebLinkAboutpitkin.eh.264307310001 (2004)Document Layout (From Most Recent to Oldest Permit) Permit Application Log Sheet/Notes & Photos Communications As -built Design Engineer Design Soil Information Water Permit & Information Second System on property Third System .etc. Floor Plans Please See Building and Land Use Approvals Files for additional information. Pitkin County Environmental Health Departme Per *r an Individual Sewage Disposal IV 0405 le Creek Road, Suite 10, Aspen, Colorado 1 Phone 970-920-5070 / FAX 970-920-5077 Permit# 04093 ParcellD # 2643-073-10-001 Type of permit New( ) Repair( ) Addition/Remodel to House( X ) Name of Owner Tommy Mottola Street Address 1801 Lake Wild Cat Rd. Property legal description Lot 15, Wild Cat Size of lot 450 acres Total square footage of the house Water source Community Water System # of bedrooms in house +2 # of offices, lofts & similar sized rooms in house Caretaker unit detached Total square footage of the caretaker unit 900 sq ft # of bedrooms in caretaker unit 1 # of offices, lofts & similar sized rooms in caretaker unit Designed for what # rooms (list) 2 bedroom addition to main house (will need tank permit) + 2 bdrm CDU/barn Permit information Designed by All Service Septic (Tim Petz) Mailing Address PO Box 2844, Glenwood Springs, CO 81602 Perc rate 39 mpi Profile hole depth 8 ft Depth to groundwater or bedrock 8 ft Minimum Septic tank capacity 656 gallons (CDU/barn) Minimum Absorption area 765 sq.ft w/ 50% reduction Comments Septic permit approved per compliance with the engineer design and specifications dated October 31, 2004. Any changes must be approved by this department and the design engineer rior to them being made. This system was installed without a permit. Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin County ISDS regulations. During the initial site investigation, water was present at the bottom of the profile hole (8 feet). There was significant rain and snow in the days preceding the site visit. This design calls for one 1500 gallon two compartment tank with an effluent filter on the outlet. A distribution box will distribute the effluent to four trenches. It appears the trenches were installed outside of the building envelope. Sign off from Snowmass Village Building dept must be obtained. Standard Infiltrators were used, each row having 13 chambers. There must be 6 feet of undisturbed soil between each trench. This department does not endorse any brand of products. This permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an as -built letter to this department. This department must also be called for an inspection with a minimum of 48 hours advanced notice. 'Revegetation over the area of the field is very important for the functioning of the system. Pitkin County has guidelines that must be followed to assure the plants that are introduced are appropriate for the conditions of the area. The use of native plants is strongly Permit approved by: JA f. n . k'h C IX— Date: Plans and specifications of the proposed individual sewage disposal system have been reviewed and are considered satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was issued unless system construction has commenced or an extension has been approved in writing by the Department. As -built drawings must be included with this permit before the final approval will be issued. Installer: Western Colorado Excavating Final approval: 1 'CA h nQd _ Date: ��� i� f ASAT DRAWING OF ONSITE I� WASTEWATER SYSTEM SCALE 1"=50' NORTH 500.0ALLON LEANOUTS 1 TWOCOMPARTMENT I PRECAST CONCRETE SEPTI: TANK WITH EFFLUENT FILTER ON OUTLET 4' PVC UNE / I PROPOSED2 BEDROOM CARETAKER 1 UNTT/6ARN DISTRIBUTION BOX (UNDER OR FLOW SPUTTER BASIN I CONSTRUCTION) i RETAINING WALL I GARAGE DRIVE 0 0 SBS SF OF INFILTRATIVE AREA IN FOUR GRAVELLESS TRENCHES TRENCHES={ CHAMBERS PER TRENCH =13 TOTAL NUMBER OFCHAMBERS=S2 OBSERVATION PIT - 14 FT DEEP, NO WATER OBSERVED' ON 11-11-04 SLOPE PIPES 1801 LAKE WILDCAT ROAD ALL HOMESTEAD 11, WILDCAT RANCH SERVICE SEPTIC, LLC PROJECT NO. 1036 970-618-5033 FIGURE 1 Pitkin County Environmental Health Department Perr an Individual Sewage Disposal SM 0405*e Creek Road, Suite 10, Aspen, Colorado 1 Phone 970-920-5070 / FAX 970-920-5077 Permit # 04087 Parcel ID # 2643-073-10-001 Type of permit New( ) Repair( ) Addition/Remodel to House( X ) Name of Owner Tommv Mottola Street Address 1801 Lake Wild Cat Rd. Property legal description Lot 15, Wild Size of lot 450 acres Water source Comm # of bedrooms in house Caretaker unit detached Water Total square footage of the house # of offices, lofts & similar sized rooms in house Total square footage of the caretaker unit 900 # of bedrooms in caretaker unit 1 # of offices, lofts & similar sized rooms in caretaker unit Designed for what # rooms (list) 2 bedrooms Permit information Designed by All Service Septic (Tim Petz) Mailing Address PO Box 2844, Glenwood Springs, CO 81602 Perc rate 39 mpi Profile hole depth 8 ft Depth to groundwater or bedrock 8 ft Minimum Septic tank capacity 656 gallons Minimum Absorption area 327 sq ft w/ 50% reduction Comments Septic permit approved per compliance with the engineer design and specifications dated October 15, 2004. Any changes must be approved by this department and the design engineerrp for to them being made. Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin County ISDS regulations. The installation of the chambers must remain shallow. No part of the trenches should be buried more than 4 feet because of the presence of groundwater at 8 feet. This design calls for one 1000 gallon two compartment tank with an effluent filter on the outlet. A distribution box with a baffle will distribute the effluent to two trenches. If Standard Infiltrators are used, each row will have 11 chambers. If Quick 4's are used, there should be 25 chambers in each trench. There must be 6 feet of undisturbed soil between each trench. This department does not endorse any brand of products. This permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an as -built letter to this department. This department must also be called for an inspection with a minimum of 48 hours advanced notice. 'Revegetation over the area of the field is very important for the functioning of the system. Pitkin County has guidelines that must be followed to assure the plants that are introduced are appropriate for the conditions of the area. The use of native plants is strongly Permit approved by: C�(ja_ 27l (jt( ( Date: l 0 2 Plans and specifications of the proposed individual sewage disposal system have been reviewed and are considered satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was issued unless system construction has commenced or an extension has been approved in writing by the Department. As -built drawings must be incled with this permit before the final approval will be issued. Installer: sta,lf] !U10-1cli-i , �j�l�iav��i f:n �Ttrrt�ti��u� g8q,0-Mb Final approval: Date: q PITKIN COW ENVIRONMENTAL HEALTH DEMENT APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM 0405 Castle Creek Road, Suite 10, Aspen Colorado 81611 Phone (970) 920-5070 Fax (970) 920-5077 Name of OWNER p,�p1 t�. f D qIL Owner's Mailing Address nI a City, State, Zip a fti RS In 15 Business Phone: Home Phone: E-mail Address: Primary Contact Person (all communication regarding this permit will go through this person) Name 5t-141 . /I . /1 Company q /ice �J Contact Mailing Address [}07 v V AC City. Stale, Zi ev Business Phone Cell Phone: _ Fax: 6 -�? ` / E-mail Address: Parcel ID # (available from assessor's office / u at 920-5160 or at www.pitkinassessor.org) - �/ 7 y� • Q Building Permit # (if available) Street address of property / 4i O J Lal if L ✓ ; Legal Description: Lot 5 Block Filing Size of lot:_ acres. --i—Ty—pe of proposed structure: ,Subdivision Total square feet of house ��! O # of bedrooms (potential) in house Caretaker Unit: Attached ( )'--Detached ( ) Total area(sa. ft.) of caretaker unit - — Permit is for: New Home ( ) Repair due to failure ( ) Remodel/Addition ( ) Emergency use ( ) Water: Private well ( ) Spring ( ) Stream ( ) Community/Public Water System (.-r If community system: Name of system Cpl lel I The fee for a ISDS application is $600 for a permit that takes 6 hours or less for the department to approve. If approval takes longer than 6 hours, a rate of $100 per hour will be charged. The maximum fee is $1000. The basic fee of $600 is due at the time of application. The remainder, if any, will be due in two stages: first, at the time of issuance of the ISDS permit; second, before final approval of the ISDS permit. Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information is We and accurate and that 1 have provided true and accurate information on locations of all existing and proposed wells, contour intervals, buildings, property lines, ditches, slopes, waterlines, springs, suction or irrigation lines, drinking water cisterns, drain tiles, irrigation ditches, lakes, water courses, streams, floodplains, dry gulches, and existing septic systems. I hereby certify that any such features not shown on attached site map are not present. Issuance of the permit does not imply the approval of any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all approvals and permits have been obtained. The Pitkin County Environmental Health Department, Pitkin County and employees of these agencies will be held harmless should the individual sewage disposal system fail or malfunction. The permit to construct is issued on information submitted by the applicant or his/her representatives. The owner assAes full responsibility in case of failure of the system. Signature of applicant Date / /� / -'c Received by Id`��cw / Receipt# Date G:Vsdsysds appiictisdsapp rev072904.doc Pitkin County Environmental Health Department Contact Log Sheet Name: Parcel ID#: Address: Dae Person Spoken To Comments / Action to be Taken Initials Ti s U n o 0 0 phone 970-920-5438 fax 970-920-5077 0405 Castle Creek Rd, Aspen CO 81611 e-mail carlab@ci.aspen.co.us :MMr4;OA To: Ryan Harrington From: Carla Block Fax: 963-4591 Pages: 2 Phone: Date: 11/8104 Re: septic permit t } I i. CC: ) -21(o 771 �c OI23 I$17l Tim Petz/ Town of Snowmass Village ❑ Urgent El For Revlew Comment ❑ Please Reply ❑ Please Recycle have re -issued the permit for pdottola. I voided permit #04087 and reissued the permit under #04093. However, this expanded system was installed prior to permitting. There are several issues that need to be addressed before final sign -off. 'emended, the trenches extend beyond the parameter of the building envelope. Snowmass Village will ✓/need to determine if this extension meets their criteria, or if the building envelope will need to be amended, or I the system will need to be relocated. A new as -built drawing is needed from the design engineer. The locations of the tank and trenches have been changed. The as -built should reflect these changes. e parts of the trenches have been installed up to 8 feet in depth. Inspection of the profile hole on Zth 20/04 indicated water at the bottom of the 8 foot profile hole. There had been rain and snow during days preceding the inspection. The installer indicated all soils during the excavation were dry. Confirmation of depth to groundwater is needed. A boring could be done near the deepest end of the trenches to assure there is 4 feet below the bottom of the trenches without encountering groundwater. If you have any questions regarding this permit, please give me a call. Thank you, Cada 10/13/2004 04:20 3032162796 B«. 9110 CA2LP�INX,4CY PETZ Ll ALL SERVICE septic, LLC PO Box 2e". GW wood Spdr%M CO 81602 M-97061&50.93 Fox 303-216-2798 tbnpstz@"*iMim.com For Your Viewing Pleasure PAGE 01 RECEWED OCT 13 2004 PITKIN COUNTY ENVIRONMENTAL HEALTH lc) -k3 _o-� Contact: 124A 3 -19-7'-7(0F Address: I%(:) 1 W t ZcAT PAN CF► W. Project: �c�r�»tEaa W t%:Z CA7 IRRty ca Map and Notes: C� F— �F�O BARtJ (k)NOW ceNuSZMvC-TtO^t StzP-'C'j &-CW r W aj\& Rai M l��Rtz�r�c�=�a►� Co���ci t� 1��2010�� VN Wi n 0-v\ M LC) 10 1 3 `fin C,3 Fl PO Box wood S�IIIIV� I ,97"F. 116136; CO 81602 November 15, 2004 Harrington Construction, Inc. Attn: Ryan Harrington 102 Beaver Lane Carbondale, Colorado 81623 Installation Observations Proposed Caretaker/Barn 1801 Wildcat Ranch Road Homestead 11, Wildcat Ranch Pitkin County, Colorado Mr. Harrington, Project No. 1036 ALL SERVICE septic, LLC performed an installation observation on November 5 and 11, 2004 for the subject property. The installation included one 1500 -gallon, two-compartment precast concrete septic tank with an effluent filter on the outlet, followed by 806 square feet of drain field. The drain field consisted of 4 rows of 13 gravelless chambers, for a total of 52 chambers. A distribution box was installed to distribute effluent. The trenches were installed at a depth of 8 feet at the east end of the trenches. A secondary 14 -foot profile pit was dug to confirm groundwater conditions. No water was observed on November 11, 2004. The drain field was installed with the potential to construct a 2 -bedroom addition in the future. All Service Septic, LLC, and the county must be contacted to view any additional construction. The OWS was installed according to specifications. This observation is not a guarantee of workmanship and/or parts and materials. ALL SERVICE septic, LLC should be notified if changes are made to the OWS. Please call with questions. ALL SERVICE tic, LLC Reviewed By: C,�;�''p HEl1gF •r • 38662 Timothy R. Petz Richard H PeiF S 2 copies sent S1 ~���� p ONA L EH Copy sent to Pitkin County Environmental Health Department, Attn: Car ■■ now *1 1 - 1500 -GALLON, TWO-COMPARTMENT ■ CLEANOUT PRECAST CONCRETE SEPTIC ■ TANK WITH TANK SPECIFICATIONS EFFLUENT FILTER ON OUTLET 4" PVC LINE ■ O --P_2 o P-1 � FILo O DISTRIBUTION BOX )N) OR FLOW SPLITTEF i 2ETAINING WALL DRIVE 775 SF OF INFILTRATIVE AREA IN GRAVELLESS TRENCHES TRENCHES =4 CHAMBERS PER TRENCH = 13 �..r., .0 n.nrn nr ni ,eunrnn.en CAPACITY REQUIRED (CARETAKER/BARN) = q X 1.75 X (30 HOURS/24 HOURS) = 656 GALLONS CAPACITY REQUIRED (2 BED ADDITION) = q X 1.75 X (30 HOURS/24 HOURS) = 675 GALLONS PROPOSED TANKS =TWO 1500 -GALLON, TWO COMPARTMI CONCRETE SEPTIC TANKS WITH EFFLUENT FILTERS AND PUMPS ALTERNATIVE OPTION = ONE 1000 -GALLON, 2-COMPARTME SEPTIC TANK WITH EFFLUENT FILTER FOR CARETAKERBARN. ONE 1250 -GALLON, 2 -COMPARTMENT SEPTIC TANK WITH PUMP AND FILTER FOR ADDITION. HOMEOWNER HAS OPTED TO UPSIZE TANKS. 10ft SETBACT TO PROPERTY LINE SECTION OF TYPICAL CHAMBER-- i HAMBER= ` ■ 4" PVC ■ OBERVATION PIPE \ GRAVELLESS 4.0' MAX CHAMBER PO ` ■ T3-,,bOvicl 023-I$l01 Fre-yu - o► `(� V AA �A cam } ■ / r 6' MIN = SCARIFY \ LIMIT OF EXCAVATION SURFACE •. �d`��O kcc( (nz1aof *(u LT +--o`1,�,z Ea-� b fin, Yn cw i -o o s-ri -�, a"o c6" �y. e aQ &e -a " �en *L,, tN,_Vl e L o ti -3 le,e ) n qS�x(CAe +ti wad iuv ` o cm6 fs, appy -N nu`FGIci o4v l lc[ i n9 \Qr\,rt (tW . ASPEN/PITKIN ENVONMENTAL HEALTH DEPART ISDS DESIGN CALCULATIONS Owner's Name Parcel ID # - House Size (sq. ft.) (75 gpd, 100 gpd, or 130 gpd) 100 Number of Bedrooms in Main House 2 Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House Number of Bedrooms in Detached Caretaker unit Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit (If the caretaker unit is ATTACHED, treat as if part of main house.) Average Daily Waste Flow 700 State Review Required? no Perc Rate 39 (T) Design Flow (Q) = # potential bedrooms X 2 people/ bedroom X gpd X 1.75 Q= 1225 Absorption Area (=Q/5 X SQRT perc rate) A= 1530.0245 sq. ft. of absorption area required 99 gravelless chamber units without reduction # of Perc Holes Required: 3 1 in every soil type? Spaced uniformly over proposed area? A maximum 30% reduction is allowed for use of deep gravel or gravelless chambered system, only if the lot size and soil conditions are optimal. If a reduction is being proposed, describe why lot size and soil conditions are optimal: 2 A = 1071.0172 sq.ft. w/30% bed reduction 765.012255 sq.ft. w/ 50% trench reduction 69 gravelless chamber units 49 gravelless chamber units Type of system: OAbsorption trenches OAbsorption bed 0 Gravelless chambers ODry well OSeepage Pit DOther (type) Mininrtnntank capacity +0 .VIVS SETBACK FROM WELL # of feet = 118 SETBACK FROM POND, STREAM OR IRRIGATION DITCH # of feet = 68 SETBACK FROM DRY GULCH # of feet = 43 Printed on Recyded Paper ��tbt&g. ft ft PITKIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT Percolation Test and Soils Data Form - TABLE 1 - PROJECT 1036 PROFILE PIT Date of Test: 10-7-04 0-6" Clayey Root Zone 6" - 8' Clay, Sandy, Stiff to Very Stiff, Moist, Grey No bedrock encountered la Ground water encountered at 8 feet Hole Hole Interval Measurement at Measurement at Change (in.) Percolation Rate No. Depth (in.) (min.) Start of Interval End of Interval (min.fin.) MPI (in.) (in.) 1 35 20 3.25 4.50 1.25 20 4.50 5.25 0.75 20 5.25 6.00 0.75 20 6.00 6.50 0.50 20 6.50 6.75 0.25 80 20 6.75 7.25 0.50 2 31 20 4.00 5.25 1.25 20 5.25 6.00 0.75 20 6.00 7.00 1.00 20 7.00 7.50 0.50 40 20 7.50 8.25 0.75 20 8.25 9.00 0.75 3 33 20 7.00 8.50 1.50 20 8.50 11.00 2.50 20 3.25 5.00 1.75 20 5.00 5.75 0.75 27 20 5.75 6.75 1.00 20 6.75 8.00 1.25 4 30 20 13.00 14.75 1.75 20 14.75 16.25 1.50 20 16.25 17.25 1.00 20 17.25 18.25 1.00 20 20 18.25 19.50 1.25 20 19.50 21.00 1.50 la ft 00 )3 Pitkin County Health Department Percolation Test Result Form Hole Hole Interval Measurement at Measurement at Change (in.) Percolation Rate No. Depth (in.) (min.) Start of Interval End of Interval (min./in.) MPI (in.) (in.) 5 28 20 10.25 12.00 1.75 20 12.00 13.50 1.50 20 13.50 14.25 0.75 20 14.25 15.00 0.75 20 15.00 15.75 0.75 27 20 15.75 16.75 1.00 AVERAGE = 39 MPI Project No. 1036 )3 flLl�. SfflYICf M �"� Harrington Construction, Inc. Attn: Ryan Harrington 102 Beaver Lane Carbondale, Colorado 81623 0 RECEIVED NOV 0 5 2004 PITKIN couNTy ENVIRONMENTAL HEALTH Project No. 1036 Subsurface Investigation and Revised Onsite Wastewater System Design, Proposed Caretaker/Barn 1801 Wildcat Ranch Road Homestead 11, Wildcat Ranch Pitkin County, Colorado Mr. Harrington, ALL SERVICE septic, LLC performed a percolation test and a revised onsite wastewater system (OWS) design for the caretaker unit at the subject property. The property is located in Wildcat Ranch, in an area where OWS are necessary. Wildcat Ranch water service will provide water to the proposed structure. This letter is to be used in conjunction with plans provided. SITE CONDITIONS There is an existing residence on the subject property, utilizing a drain field located to the south, as indicated on Figure 1. The proposed IVIS. MY ue to the size of the structure the drain field will be sized based on �'he proposed addition habUmgq,,bedQo®m�s and`b n 190U a> 66 5�,aft SUBSURFACE The subsurface was investigated by excavating an 8 -foot test pit near the proposed drain field location as shown on attached plans. The test pit indicated the site has a 6 -inch root zone layer, underlain by sandy clay to the maximum depth explored of 8 feet. Groundwater was measured at 8 feet. No bedrock was encountered. Due to percolation rates and subsurface data obtained, the drain field should be placed over percolation holes 4 and 5, as shown on plans provided. M r • Revised OWS Design for Caretaker/Barn Project No. 1036 Page 2 OPERATION INFORMATION AND MAINTENANCE The surface of the drain field should be seeded upon completion. Vegetation is an important factor in drain field performance. Geo -fabrics or plastics should not be used over the drain field. Livestock should not graze on the drain field. The homeowner should pump the septic tank every two years and clean the effluent filter as needed. Garbage disposal use should be minimized, and non -biodegradable materials should not be placed into the OWS. Loading from a water softener should not be discharged into the OWS. No hazardous wastes should be directed into the OWS. Mechanical room drains should not discharge into the OWS. The OWS is engineered for domestic waste only. INSTALLATION OBSERVATIONS ALL SERVICE septic, LLC, and the county must view the installation during the OWS construction. The OWS observation should be performed before backfill, after placement of chambers and distribution pipes. Septic tanks, distribution devices, pumps, dosing siphons, and other plumbing, as applicable, must also be observed. ALL SERVICE septic, LLC should be notified 48 hours in advance to observe the installation. LIMITS: The design is based on information submitted. If soil conditions encountered are different from conditions described in report, ALL SERVICE septic, LLC should be notified. All OWS construction must be according to the county regulations. Requirements not specified in this report must follow county regulations. The installer should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. Please call with questions. ALL SERVICE septic, LLC Timothy R. Petz 3 copies 1j. Reviewed Richard H. •SITE PLAN SCALE 1"=150' NORTH PROPOSED 2 BEDROOM CARETAKER BUILDING lu HOMESTEAD 11, WILDCAT RANCH ALL 1801 WILDCAT RANCH ROAD SERVICE SEPTIC, LLC 10-31-04 PITKIN COUNTY COLORADO 970-618-5033 FIGURE 1 Pump Selection for a Non -Pressurized System r Input Parameters Design Flow Rate 20 gpm Distributing Valve Model None Lift to Discharge 25.0 feet Transport Length 250.0 feet Transport Line Size 2.00 inches Transport Pipe Class/Schedule 40 Discharge Assembly Size 1.25 inches Flow Meter None inches 'Add-on' Friction Losses 0.0 feet cwaumn Head Loss Through Distributing Valve 0.0 feet Head Loss in Transport Pipe 1.8 feet Head Loss Through Discharge 2.0 feet Head Loss Through Flow Meter 0.0 feet 'Add-on' Friction Losses 0.0 feet Total Flow Rate 20.0 gpm TDH 28.8 feet Lot 11, Wildcat Ranch Project No. 1036 300 27 24 W 6 3i P3015 Effluent Pumps P30 Series 1/2 hp to 1-1/2 hp TELEPHONE: (541)459-4449 P3010 FACSIMILE: (541)459-2897 I www.orenco.com P3007 I P3005 0 0 10 20 30 40 Net Discharge, gpm Orenco Systems Incorporated 814 AIRWAY AVENUE SUTHERLIN. OREGON 97479 • TOLL FREE (8001348-9843 TELEPHONE: (541)459-4449 FACSIMILE: (541)459-2897 www.orenco.com F N �,Cj- ,7,1\10 ov 0 5 2004 . v vg'd'O01.NTY EPN(RI ljhFNTALh9E4LTH . \`yti �, V 7� , SCALE 1"=20' ■®® NORTH ■ ® in 1500-GALLOI ®� TWO-COMPARTMENT CLEANOUT ' PRECAST - ■ � CONCRETE SEPTIC ■ ■ TANK WITH EFFLUENT FILTER ON OUTLET 1500 -GALLON, TWO-COMPARTMENT PRECAST CONCRETE SEPTIC TANK WITH PUMP AND FILTER IN SECOND COMPARTMENT PROPOSED TWO-BEDROOM ADDITION EXISTING RESIDENCE THE LOCATION OF EXISTING AND PROPOSED IMPROVEMENTS SHOWN ARE NOT THE RESULT OF A PROPERTY SURVEY. THE LOCATIONS ARE APPROXIMATE. IT IS THE HOMEOWNERS DUTY TO ENSURE ALL CONSTRUCTION AND IMPROVEMENTS LOCATIONS ARE ACCURATE. ALL SETBACK DISTANCES SHOULD BE CONFIRMED PRIOR TO EXCAVATION. CLEANOUT it -10241,42W PROPOSED2 BEDROOM CARETAKER UNIT/BARN (UNDER CONSTRUCTION) 4" PVC LINE DISTRIBUTION BOX OR FLOW SPLITTEF RETAINING WALL DRIVE P-1 775 SF OF INFILTRATIVE AREA IN FO GRAVELLESS TRENCHES TRENCHES =4 CHAMBERS PER TRENCH = 13 TOTAL NUMBER OF CHAMBERS = 52 .4, ~RFS. FILE ems' P-5 Effluent Pumping System -1500-Gallon, 2 -Compartment . 1801 WILDCAT RANCH ROAD HOMESTEAD 11, WILDCAT RANCH Fiberglass or concrete riser PVC Riser With Grommet(s) (bond to tankadapter w'dh GLENWOODSPRINGS, C081602 970-618-5033 PITKIN COUNTY, COLORADO Project No. 1036 10-31-04 recommended adhesive) Slope Ground Fiberglass Gosketed Lid with Away from ISser ~- Stainless Steel Bolls TANK SPECIFICATIONS Conduit toPJC Splice Box with Cord Grips Control Panel Discharge Assembly CAPACITY REQUIRED (CARETAKER/BARN) = q X 1.75 X (30 Conduit Seal Flexible Hose HOURS/24 HOURS) = 656 GALLONS Inlet Tee or Tank Adapter (oast bolted) --\Effluent D urge CAPACITY REQUIRED (2 BED ADDITION) = q X 1.75 X (30 Liouid Level o HOURS/24 HOURS = 875 GALLONS =_ Level Control Float Assembly PROPOSED TANKS = TWO 1500 -GALLON, TWO COMPARTMENT, Check Valve (optional) CONCRETE SEPTIC TANKS WITH EFFLUENT FILTERS AND pale wall VauR Inlet Ports PUMPS Orenoo Effluent Pump Filter Cartridge ALTERNATIVE OPTION = ONE 1000 -GALLON, 2 -COMPARTMENT Drain Port SEPTIC TANK, WITH EFFLUENT FILTER FOR Biotube® Pump Vault CARETAKER/BARN. ONE 1250 -GALLON, 2 -COMPARTMENT SEPTIC TANK WITH PUMP AND FILTER FOR ADDITION. Potents ! 4,439,323 a 5.492.635 HOMEOWNER HAS OPTED TO UPSIZE TANKS. ® zmo� ®ooPendingy Inc. 1 Oft SETBACT TO i PROPERTY LINE ROSS SECTION OF TYPICAL CHAMBER -TRENCHES TRENCHES 4" PVC MUST BE OBERVATION LEVEL PIPE GRAVELLESS 4.0' MAX CHAMBER 1.5' MIN ® 6' MIN----w­i� LIMIT OF EXCAVATION SCARIFY SURFACE r \y 1 r �r OBSERVATION PIPES SLOPE Orenco Systems® iroomomWc1 814 ARWAY MII81E WHO". arBS,OH 17478-0812 1ftEP11ar - (541) 459-4449 FACwweE (541) 459-2584 DESIGN TWO - BEDROOM CARETAKER/BARN, <2000 SF = 300 GALS PER DAY TWO - BEDROOM ADDITION, 2000-6000 SF = 400 GALS PER DAY TOTAL LOADING = q = 700 GALLONS PER DAY PERCOLATION RATE = 39 MINUTES PER INCH CALCULATED AREA = ((1.75 X q) X sgrt 39) / 5 = 1530 SF REDUCTION OF 50% = 765 SF TRENCH SPECIFICATIONS WIDTH OF TRENCHES = 3 FEET = 1 CHAMBERS LENGTH OF TRENCHES = 81.25 FEET = 13 CHAMBERS TOTAL NUMBER OF CHAMBERS = 52 TOTAL INFILTRATIVE AREA = 775 SF FOUR TOTAL TRENCHES NOTES: TRENCHES MAY BE ANGLED TO FIT TOPOGRAPHY AND TO MINIMIZE REMOVAL OF TREES. THE 15 DEGREE INFILTRATOR (TM) WEDGE MAY USED. THE SLOPE AT THE PROPOSED DRAIN FIELD IS APPROXIMATELY 10% TO THE NORTHEAST. VEGETATION CONSISTS OF A MODERATE COVER OF SAGE BRUSH WITH JUNIPER TREES. LIMITATIONS - THESE PLANS MUST BE USED IN CONJUNCTION WITH LETTER AND SOILS DATA FORM PROVIDED. THE DESIGN IS BASED UPON INFORMATION SUBMITTED. IF SOIL CONDITIONS ENCOUNTERED ARE DIFFERENT FROM CONDITIONS DESCRIBED IN REPORT, ALL SERVICE SEPTIC L.L.C. SHOULD BE NOTIFIED. ALL OWS CONSTRUCTION MUST BE ACCORDING TO COUNTY REGULATIONS. THE INSTALLER SHOULD HAVE DEMOSTRATED KNOWLEDGE OF THE REQUIREMENTS AND REGULATIONS OF THE COUNTY IN WHICH THEY ARE WORKING. THE COUNTY AND ALL SERVICE SEPTIC L.L.C.MUST VIEW INSTALLATION ALL SERVICE septic, LLC PO BOX 2844 1801 WILDCAT RANCH ROAD HOMESTEAD 11, WILDCAT RANCH REVISED ONSITE WASTEWATER SYSTEM DESIGN FIGURE 2 GLENWOODSPRINGS, C081602 970-618-5033 PITKIN COUNTY, COLORADO Project No. 1036 10-31-04 ;<t