0ONSITE WASTEWATER TREATO JT SYSTEM (OWTS)
CEH/N:R1 CONSTRUCTION PIMMIT
0405 Castle Creek Road, Suite 10 Aspen, CO 81611
Phone: 970.920.5070 Fax: 970.920.5077
Permit#: 07094 B (reissued) Parcel ID#: 2643-081-03-008
Permit Issued:
2 NEW ❑ REPAIR
❑ AMENDMENT
❑ REMODEUADDrriON ❑ TANK ONLY ❑ FIELD ONLY
Owner(s): River Woods Holding, LLC
Property Address: 0200 River Woods Road
Legal Description: Lot A Pitkin Iron/River Woods PUD
Size of Lot: 3.725 acres Acres Detached Accessory Unit:
Size of Building 5,369 Sq. Ft. Size of Accessory Unit Sq. Ft.
FThissystem is designed for 4 Bedrooms.
Designed By:
HP Geotech
Phone #:
970-468-1989
Fax #:
970-468-5891
Project #:
407-0299 Dated: 5/7/2008
Mailing Address: PO Drawer 1887, Silverthome CO 80498
Email Address: hoaeo4CrDhoaeotech.com
Perc Rate: .95 AR Profile Hole Depth: 8 ft Depth to Groundwater or Bedrock: 3-1/2 ft
Minimum Tank Capacity: 1250 gallons Minimum Absorption Area: 947 sf sand filter
Permit Conditions:
This permit is re -issued for a new design based on potential seasonal groundwater in this area. It is for 2,00
gallon, 3 -chamber Valley Precast concrete septic tank, or equivalent. The third chamber shall contain an
Orenco Biotube Pump vault to dose to a semi -mounded absorption area. The mound shall be 20 ft by 48 ft
with 2 feet of sand fill, no deeper than one foot below existing ground surface. The sand shall be thoroughly
settled before the distribution pipes are placed on the filter material.
This OWTS Construction Permit is approved on the condition of compliance with the engineer design as submitted with the
application and the specifications cited above. Any changes must be approved by this Department and the design engineer
prior to construction.
This Permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an
"as -built" letter to this Department within 30 days of the final inspection, unless a longer period of time has been agreed upon
in writing. This Department must also be called for the final inspection with a minimum of 48 hours notice.
Minimum horizontal distances between components of the system and physical features shall conform to the requirements of
the Pitkin County OWTS Regulation.
This permit is conditioned upon the property owner(s) providing for the regular inspection, cleaning, and maintenance of the
system by qualified personnel, in accordance with the manufacturer's recommendations and the requirements of the Pitkin
County OWTS Regulation.
THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN COUNTY OWTS
REGULATION, INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE.
Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given
to the property owner(s) to perform the work indicated in accordance with the Pitkin County OWTS Regulation. This Permit will
expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built" drawing must be submitted
and approved by EH/NR before final approval of the system will be issued.
Issued By: Date: 2 2-,Z()r Expires: -5/ 22 09
Reactivation Authored by:
Installer. 0 U00i License #:
Final Approval Issued By: , Date: <5 New Expiration Date: ❑ Fee Paid
., i
al
PITKIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM
0405 Castle Creek Road, Suite 10, Aspen Colorado 81611
Phone (970) 920-5070 Fax (970) 920-5077
Name of OWNER
Owner's Mailing Address
E-mail Address:
Business Phone:
ANlll wall communication regarding this permit will go through this person)
Name B. Joseph Krabacher
Company Krabacher 6 Sander
Contact Mailing Address 201 N. Mill Street. guit-P 9n]
City, State, Zip ASDen r0 91611 Business Phone 970 925 6399 m 222
Cell Phone : 970 4 2277 Fax: E-mail Address:
Parcel ID # (available from assessor's office 2 6 4 30 8 1 0 3- 0 0 8
at 920-5160 or at www.pitkinassessor.oro ) _ _ _ _ - _ _ _ - _ _ _
Building Permit # (if available) not issued yet
Street address of property 0200 River Woods Road Woody Creek CO R16S6
Legal Description: Lot A Block Filing Subdivision Pitkin
Size of lot: 3.725 acres. Type of proposed structure: single family residence
Total square feet of house 5,369± # of bedrooms (potential) in house 4
Caretaker Unit: Attached ( no Detached ( no)
Total areas . ft. of caretaker unit # of bedrooms(potential) in caretaker unit
Permit is for: New Home ( xx)
Water: Private well ( XX) Spring
Repair due to failure ( ) Remodel/Addition ( ) Emergency use ( )
) Stream ( ) Community/Public Water System ( )
lim
If community system: Name of system ICU
The fee for an ISDS application is $623 for a permit that takes 6 hours or less for the department to approve. If approval takes
longer than 6 hours, a rate of $100 per hour will be charged. The maximum fee is $1000. The basic fee of $623 is due at the
time of application. The remainder, if any, will be due in two stages: first, at the time of issuance of the ISDS permit; second,
before final approval of the ISDS permit.
Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information is true and
accurate and that I have provided true and accurate information on locations of all existing and proposed wells, contour
intervals, buildings, property lines, ditches, slopes, waterlines, springs, suction or irrigation lines, drinking water cisterns, drain
tiles, irrigation ditches, lakes, water courses, streams, floodplains, dry gulches, and existing septic systems. I hereby certify that
any such features not shown on attached site map are not present. Issuance of the permit does not imply the approval of any
other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all approvals I
and permits have been obtained.
The Pitkin County Environmental Health and Natural Resources Department, Pitkin County and employees of these agencies
will be held harmless should the individual sewage disposal system fail or malfunction. The permit to construct is issued on
information submitted by the applican s/her representatives. The owner assumes full responsibility in case of failure of the
system.
Signature of applicant ; Date
war �11�� /
Received by(! Receipt # �l>2 Date G
G:\isds\isds applic\isdsapp rev052207.doc
Pitkin Coun wnvironmental Health & Natural Res es Department
It for an Individual Sewage Disposamill
0' Castle Creek Road, Suite 10, Aspen, Colorado 81611
Phone 970-920-5070 / FAX 970-920-5077
Permit# 07094 Parcel ID# 2643-081-03-008
Type of permit New(x) Repair( ) Addition/Remodel to House( )
Name of Owner River Woods Holding, LLC
Street Address 0200 River Woods Road, Woody Creek
Property legal description
Size of lot 3.725 acres
Water source Private well
# of bedrooms in house
Caretaker unit
# of bedrooms in caretaker unit
Designed for what # rooms (list)
Designed by
Mailing Address
Lot A, Pitkin Iron/ River Woods PUD
Total square footage of the house 5369
ft
# of offices, lofts & similar sized rooms in house
Total square footage of the caretaker unit
# of offices, lofts & similar sized rooms in caretaker unit
4 bedrooms—�
HP Geotech
Permit information
PO Drawer 1887, Silverthorne, CO 80498 J 1
Perc rate 11 Profile hole depth 8 ft
Minimum Septic tank capacity 1750 gallons
Septic permit approved per compliance w
0299. Any changes must be approved by
j
th�undwater bedrock Greater than 8 ft
Minimum orption area 650 sq ft w/ 30% reduction
Comments
er design and specifiqations dated October 4, 2007, F
pnt and the design a gineer prior to them being made.
Minimum horizontal distances between compon nts of t e system and p sisal features shall conform to the Pitkin County
ISDS regulations. There must be at least 132 fe betwe the well an he absorption area and 82 feet between any
ditch or water course and the sorption area. Th\desi
need a at least 50 feet from the ditch.
The system will consist of one 2000 Ion two cot tank followed by a 1000 gallon single compartment dosing
tank with a pump. A 2" line will carry a nt to thhe effluent line will cross a ditch and need to be encased within
50 feet of the crossing as specified in the a 'neeThe field will consist of 5 rows of 12 chambers and one row of
11 for a total of 71 Quick 4 chambers.The sy nents must be staked out and approved by this
Department prior to installation of the system.
This permit is expressly conditioned on the property owner providing for the regular inspection, cleaning and
maintenance of the system by qualified personnel, in accordance with the manufacturer's recommendations.
This department does not endorse any brand of products: This permit must be kept on-site during installation. The
engineer must do a final inspection of the installation and submit an as -built letter to this department. This department
must also be called for an inspection with a minimum of 48 hours advanced notice.
Revegetation over the area of the field is very important for the functioning of the system. Pitkin County has guidelines that must be
followed to assure the plants that are introduced are appropriate for the conditions of the area. The use of native plants is strongly
Permit approved by: (t Itt h (JA L%n h' � Date: 11 I L 0 Expiration Date:
Plans and specifications of the proposed individual sewage disposal system have been reviewed and are considered
satisfactory. Permission is hereby granted to the owner or the owner's agent to perform the work indicated in accordance with
the Pitkin County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the
permit was issued unless system construction has commenced, or an extension has been approved in writing by the
Department. As -built drawings must be included with this permit before the final approval will be issued.
Installer: License Number:
3 Final approval: Date:
M
Walthen Ditch Update - Inboxtahoo! Mail
Yahoo! My Yahoo' Mail More Make Yl My Home Page
Yg1&100►e MAIL
Classic
Mail Plus I Contacts Calendar Notepad
•
Page I of I
Hi, nancy_bill_macken... Sign Out All -New Mail Help
Search WEB SEARCH
What's New? Mobile Mail Cphgrq
Chack Mail Compose Search Mali Search the Web
Folders
Inbox (50)
Drafts (4)
Sent
Spam
Trash
(Ad0 - Edit]Previous I Next I Wick to Messages
DNeb I Reply Forward I spam I Mow... V
Walthen Ditch Update
From: "Patty Fox" <41ioxes@rof.ri
[Empty) To: Undisclosed-Recipient@yahoo.com
[Empty)
Mark as Unread I Print
Friday, June 27, 2008 11:57 AM
My Folders [Hldel
Dear Walthen Ditch Folks,
Estate Plannin... (1)
I'm sorry I have not updated you as to the workings of the ditch but like all of you, Jim and I lead busy
Jokes
lives and the volunteer time the ditch requires has begun to get to us....
outlook
The work done at the lower end of the ditch and on Dry Woody Creek, to which the ditch contributed
save
$750, definitely prevented flooding during the early part of the runoff above Aspen Valley Ranch. Jim
Sovich fence !.
and the Britvars put it many hours helping so that the total bill could be kept low. All of the downstream
Woody Creek or
neighbors, including those not on the ditch, also helped pay for the work. Now that the Ranch and other
neighbors on the mesa above us are irrigating, there is so much sub -irrigation that we need no water
on Grange Way and upstream. In fad, this week, Jim had to turn the ditch off for two days because
during the construction at River Woods (Krabacher), the basement they were digging flooded. They
Search Shortcuts
were sure it was due to the ditch leaking into their building site and so, as good neighbors, we turned
My Photos
the ditch off. The flooding continued due to the sub -irrigating, as always happens at this time of year,
My Attachments
and they have now installed pumps and are continuing with construction. The ditch is back on.
But that isn'tthe only time the ditch has been cult off, as you know. With the extremely high water
everywhere, the creek banks have been washed clean of debris — and all of that debris has found its
way into the head gates, nowhere more so than in Woody Creek. The beavers have taken advantage
of this situation and have been busy building dams. Bob Olson and his employee, Hugo, (whom Bob
has insisted on paying without help from the ditch) and Jim Fox have been cleaning the headgate and
flue EVERY DAY and sometimes twice a day to try to keep the ditch open. With the high -running water,
this has been difficult and sometimes dangerous work. It's a shame that more of you, or your
employees, have not been able to help and thereby to appreciate the enormous amount of time and
effort that have gone into getting water to you at all.
As we have offered before, Jim and Bob would be glad to give you a tour to help you understand the
workings of the Walthen Ditch.
If this does not get to the appropriate property manager, please update me with you emails. I am no
longer printing and mailing updates.
Patty Fox
Delete I Rap I Forward I Spam I Move-.. �
Previous I Next I Back to Messages Select Message Encoding I Full Hea4eE5
Check Mail compose Search Mail Search the Web
Copyright 01994-2008 Yahoo! Inc. All fights reserved, Terns of Service- COpynghtllP Policy - Guidehnes
NOTICE: We collect personal information on this site.
To learn more about how we use your information, see our Privacy Policy
http://mc538.mail.yahoo.comlmclshowMessage?fid=Inbox&sort=date&order—=down&start... 6/27/2008
'q.
0 0 Page 1 of 4
Nancy Mackenzie
To: Jason Pascoe; 'Krabacher, Joe'
Cc: Carla Ostberg; 'Jim Pidcock'
Subject: RE: Location of sand mound - Lot A River Woods
Jason, Yes, the aggregate area footprint is all that needed to be staked.
From: Jason Pascoe [mailto:jpascoe@hpgeotech.com]
Sent: Tuesday, April 15, 2008 9:53 AM
To: 'Krabacher, Joe'; Nancy Mackenzie
Cc: Carla Ostberg; 'Jim Pidcock'
Subject: RE: Location of sand mound - Lot A River Woods
Perfect. Thanks for the info Joe. I will make the necessary changes and issue a new site plan this week.
As for the flagging of the mound, I believe the aggregate area footprint is what needs to be staked. This is the
important area with regards to setbacks, design size, etc. Nancy/Carla.... can you confirm what OWTS
components the County wants staked prior to your visit?
Have a good day,
Jason.
G4G tech
Hepworth-Pawlak Geotechnical
Jason Pascoe
Lab Manager, Environmental Specialist
240 Annie Road
P.O. Drawer 1887
Silverthome, CO 80498
Phone: 970-468-1989
Cell: 970-418-3870
4/15/2008
i
Email: Jpascoe@hpgeotech.com
Fax: 970-468-5891
www.hpgeotech.com
r
•
From: Krabacher, Joe [mailto:jkrabacher@krabacher.com]
Sent: Monday, April 14, 2008 5:37 PM
To: Nancy Mackenzie;jpascoe@hpgeotech.com
Cc: Carla Ostberg; Jim Pidcock
Subject: RE: Location of sand mound - Lot A River Woods
Jason
•
Page 2 of 4
Here is the survey in case you don't have it. The well is located within the well envelope on the other
side of the driveway from the septic envelope. .
Get me a plan when its revised and I will get the surveyor on site to flag the sand mound.
Thanks —Joe
B.Joseph Krabacher
Krabacher I Sanders, P.C.
201 N. Mill Street, Suite 201
Aspen CO 81611
(970) 925 6300
(970) 925 1181 fax
ikrabacher n.krabacher.com
www.krabacher.com
4/15/2008
q
• • Page 3 of 4
From: Nancy Mackenzie [mailto:nancym@co.pitkin.co.us]
Sent: Monday, April 14, 2008 5:18 PM
To: jpascoe@hpgeotech.com
Cc: Krabacher, Joe; Carla Ostberg
Subject: Location of sand mound - Lot A River Woods
Jason,
The location of the redesigned sand mound is located close enough within the designated "septic
envelope". There is no further issue with this and I will be able to issue the OWTS permit when the
other issues are resoved:
Indicated the exact location of the well on the design
Show the exact distances from the OWTS components and the well and ditch
Stake out the location of the proposed sand mound for my site visit
Nancy
Nancy MacKenzie
Environmental Health Specialist
970-920-5076
Pitkin County Environmental Health & Natural Resources
0405 Castle Creek Rd, Suite 10
Aspen, CO 81611
4/15/2008
Ib
0 0 Page 1 of 1
Nancy Mackenzie
From: Nancy Mackenzie
Sent: Monday, April 14, 2008 5:01 PM
To: Lance Clarke
Subject: RE: 0200 River Woods, Lot A - Joe Krabacher
Thank you very much!
From: Lance Clarke
Sent: Monday, April 14, 2008 4:58 PM
To: Nancy Mackenzie
Subject: RE: 0200 River Woods, Lot A - Joe Krabacher
Small potatoes -go with it.
From: Nancy Mackenzie
Sent: Monday, April 14, 2008 4:35 PM
To: Lance Clarke
Subject: RE: 0200 River Woods, Lot A - Joe Krabacher
The actual aggregate mound should be within the envelope. It will only be the'toeing' out of the soil cap to
maintain the 3 to 1 slope so it doesn't wash out that might slant out by 10 ft on one side and 1 ft on the other out
of the envelope.
From: Lance Clarke
Sent: Monday, April 14, 2008 4:12 PM
To: Nancy Mackenzie
Subject: RE: 0200 River Woods, Lot A - Joe Krabacher
From what I remember it was real close, right? It was just a matter of a few feet here and there? If so, I wouldn't
be concerned.
From: Nancy Mackenzie
Sent: Monday, April 14, 2008 4:09 PM
To: Lance Clarke
Subject: 0200 River Woods, Lot A - Joe Krabacher
Re: The design I showed you today
The final recorded plat shows what was on the septic design plat that I showed you. Each Lot had a
separate building envelope, well envelope and a septic envelope. So what is the procedure, time constraints, to
be able to allow the larger raised mound that will not fit in the designated "septic envelope"?
Nancy
.111H 11::
• • Page 1 of 1
Nancy Mackenzie
From: Nancy Mackenzie
Sent: Monday, April 14, 2008 5:18 PM
To: 'jpascoe@hpgeotech.com'
Cc: lkrabacher@krabacher.com'; Carla Ostberg
Subject: Location of sand mound - Lot A River Woods
Jason,
The location of the redesigned sand mound is located close enough within the designated "septic
envelope". There is no further issue with this and I will be able to issue the OWTS permit when the other issues
are resoved:
Indicated the exact location of the well on the degign
Show the exact distances from the OWTS components and the well and ditch
Stake out the location of the proposed sand mound for my site visit
Nancy
Nancy MacKenzie
Environmental Health Specialist
970-920-5076
Pitkin County Environmental Health & Natural Resources
0405 Castle Creek Rd, Suite 10
Aspen, CO 81611
: AUX1IIIF
0 0 Page 1 of 1
Nancy Mackenzie
From:
Nancy Mackenzie
Sent:
Thursday, April 10, 2008 3:05 PM
To:
jpascoe@hpgeotech.com'
Cc:
'ruhle@hpgeotech.com'
Subject:
River Woods Holding - Lot A - Krabacher
Jason,
I left you a voice message today about the review of this new design due to the potential of seasonal high
groundwater.
. The site map should indicate the exact location of the actual well
` Our regulations specify that a .95 loading rate is to be used for sand mounds
" I forgot to mention that the 'new' Plf loading factor of 1.4 was not used in the calculation. ( The minimum
absorption area for effluent from secondary or advanced secondary treatment may be calculated using a Plf of
not less than 1.0 when the percolation rate formula is used.)
I'll be in in the mornings on Monday & Tuesday - the 14th and 15th. Maybe we can talk about it then if you have
time. The new regs are going to take getting used to by all of us!
nancy
Nancy MacKenzie
Environmental Health Specialist
970-920-5076
Pitkin County Environmental Health & Natural Resources
0405 Castle Creek Rd, Suite 10
Aspen, CO 81611
4/10/2008
0
Go(Ptech
HEPWORTH- PAWLAK GEOTECHNICAL_
May 14, 2009
0
I lepwnrih-Pawlak (ic,aechnical, Inc.
P.O. Drawer 1887
Silveuhorne, Cnlormlo 80498
Phone: 970-468-1989
Fax: 970-468.5891
cinail: hpgco40hl1gc1rech.Co10
Joseph Krabacher
201 North Mill Steet, Suite 201
Aspen, CO 81611
Job No. 407 0299
Subject: As -Quilt Evaluation of On-site Wastewater "Treatment System, Existing
Residence, Lot A, River Woods at Woody Creek Subdivision, Pitkin County,
Colorado.
Dear Joseph:
I lepworth-Pawlak Geotechnical, Inc. has observed the installation of the Onsite Wastewater
Treatment System (OWTS) for the four bedroom residence on the project site. The OWTS
components observed include: septic tank, dosing chamber, effluent pipe, cleanouts, manifold
pipes, distribution lateral pipes, aggregate thickness, sand filter dimensions, inspection ports,
and the locations of components. We previously designed an OWTS for the subject site and
presented our recommendations in a report dated May 7, 2008, Job No.407 0299. Our
observations and recommendations are presented in the following paragraphs.
We performed our As -Built site evaluations on August 7, 2008, September 24, 2008 and May
11, 2009. A site visit was made on August 7, 2008 to observe the mounded absorption area
and sand filter prior to the placement of the soil cap. The components evaluated during the
site visit included the sand filter dimensions and thickness, aggregate bed dimensions,
distribution laterals, manifold piping, air vents and setbacks requirements from absorption
field. A site visit was made on September 24, 2008 to observe the septic tank installation,
effluent piping and sewer piping. The components evaluated included the septic tank, dosing
chamber, inlet tee, outlet tee, access risers, sewer line from residence to tank, cleanout,
encased effluent line from lank to absorption field and required setback distances to all
components. The effluent line was encased nearly the entire length (approx. 190 feet), which
is greater than the required length by Pitkin County F rivironmental I lealth due to crossing the
Walthen irrigation ditch. A site visit was made on May 11, 2009 to observe the dosing pump.
This addition visit was needed due to the lack of electrical power on our previous visits. The
/3 Glenwood Springs 970.945-7988 9 Parker 303-84t-7119 • Worado Springs 719.633.5562
0
Joseph Krabacher
May 14, 2009
Page 2
1i
components evaluated were the Orenco 131:3005 submersible effluent pump installed within
the specified Orenco Biotube Pump Vault located in the dosing chamber of the septic tank,
the Float assembly, the alarm Float and control panel. The water level in the dosing chamber
was not high enough during our site visit to trip the upper Float and dose the absorption field
manually. The dosing pump should be monitored for proper operation once the water level
reaches the correct capacity to dose the absorption field.
It is our opinion that the OWTS meets the general intent of our May 7, 2008 design report.
The OWTS As -Built site plan is shown on the attached Figure I. An As -Built Photograph
Log is also provided as an attachment.
The observations and recommendations presented above are based on our site observations
and our experience in the area. We make no warranty either express or implied. Alterations
to the system including recommended corrections, backfill and site grading could alter the
operation and effectiveness orthe OWTS. On-site observations of the OWTS backfill,
recommended corrections or other out of scope services can be provided for an additional
cost.
Please reel free to contact us iryou have any questions regarding this letter.
Sincerely, n
AWLAK GEOTECHNICAL, INC.
Environmkntal Specialist
p F. LTA
Reviewed by:
;
�f�09
George W. Benecke III, P.G.
xFSS�O.•
Associate
NAI ENG
Attachments: Figure I —OWTS As -Built Site Plan
As -Built Photograph Log
cc: Pitkin County Environmental Ilealth Department
Job No. 407 0299
,:.�•-
,r
��
�� �f at
.'
� � � � h �r y
JC-.
� � � -yam .siiy�
' _x y�
A't �Jt
t � p � / If '
i//' I 1 pp
(,I �Y'�� �� . � rzr L�t v�:+� �f��1 �;.x �hr-x,> }ex (,��xi{� r{x,4: f yi
.)I �F T'�d�'�i�� ♦ ,,�t. '6'". i�:.ix. rit�^rornxi:3�
i I -.
. '��1. is - .. ... ......
0
Job No. 407 0299
I�
0
Photograph 3: 1.5" Schedule
40 distribution laterals and
manifold installed level. The
inspection ports properly placed
in the comers of the absorption
field.
Photograph 4: Distribution
laterals embedded and getting
covered with aggregate prior to
geotextile placement.
Photograph 5: 1.5" Schedule
40 effluent pipe entering
absorption area manifold.
Effluent pipe is properly sloped
to drain back to the tank and
properly encased with solid 4"
Schedule 80 pipe.
~FIech
dM �
0
Job No. 407 0299
9
Photograph 6: Encased
effluent line crossing under
Walthen In igation Ditch
culvert.
Photograph 7: Effluent line
covered with compacted back-
fill and blue board to prevent
freezing.
Photograph 7: Septic tank
being installed.
Gtech
Job No. 407 0299
1C+
0
Photograph 9: Sewer line from
residence into first chamber of
the tank. hilet tee properly
installed.
Photograph 10: Sewer line
properly embedded with
aggregate to prevent settlement.
Photograph 11: Septic tank
backfilled with access risers
installed and effluent line
backfilled and covered, leaving
the dosing chamber.
Ge Ptech
•
ISDS DESIGN CALCULATIONS - for Pitkin
Owner's Name Parcel ID #
House Size (sq. ft.) (75 gpd or 100 gpd)
Number of Bedrooms in Main House
Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House
Number of Bedrooms m Detached Caretaker unit
Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit
(If the caretaker unit is ATTACHED, treat as if part of main house.)
Average Daily Waste Flow 600
State Review Required? no
Perc Rate (T)
Design Flow (Q) = # potential bedrooms X 2 people/bedroom X gpd X 1.5
Q= 900
Minimum tank capacity
1125 gallons
Absorption Area (=Q/5 X SQRT perc rate)(1.4 loading factor)
A = 1,333 sq. ft. of absorption area required
Absorption Area (=Q/5 X SQRT perc rate) WITH SECONDARY TREATMENT (no loading factor)
A= 952 sq. ft. of absorption area required
Abs. Area w/ locaing factor (B25)
Trench
Bed
Pipe and Gravel
1200.112795
1333.458661
Dosing
1066.766929
1066.766929
Chambers
933.4210625
1200.112795
Max Allowable
666.7293304
933.4210625
Secondary Treatment
Abs Area w/ out loading factor (B28)
Trench
Bed
Pipe and Gravel
857.2234248
952.470472
Dosing
761.9763776
761.9763776
Chambers
666.7293304
857.2234248
Max Allowable
476.235236
666.7293304
100
SETBACK FROM WELL
# of feet =
50
SETBACK FROM FOND, STREAM OR IRRIGATION DITCH
# of feet =
25
SETBACK FROM DRY GULCH
# of feet =
0U
75
H�IV*
HEPWORTH-PAWLAK GEOTECHNICAL
May 7, 2008
Hepwaawlak Geotechnical, Inc.
P. 0. Drawer 1887
Silverthome, Colorado 80498
Phone: 970-468-1989
Fax. 970-468-5891
emad: hpgeo4®hpgeotech.axn
Joseph Krabacher RECFWED
201 North Mill Street, Suite 201 MM 0 9 2000
Aspen, Colorado 81611
DITKIN C4XNTY ENVIRONMENTAL Job No. 407 0299
IIEALTH b NATURAL RESouRCES
Subject: Onsite Wastewater Treatment System Redesign, Proposed Residence,
Lot A, River Woods at Woody Creek Subdivision, Pitkin County,
Colorado.
Dear Joseph:
As requested, Hepworth-Pawlak Geotechnical, Inc. has redesigned the Onsite Wastewater
Treatment System (OWTS) for the proposed residence located at Lot A, River Woods in
the Woody Creek Subdivision in Pitkin County, Colorado. The study was conducted in
accordance with our written agreement to you through our Glenwood Springs office dated
June 29, 2007. The Pitkin County Environmental Health Department's review of the
initial design raised concern with regards to the potential for seasonal high groundwater at
the project site. The OWTS was redesigned due to the potential for shallow groundwater
at the subject site. The percolation testing discussed below was performed during a
seasonally dry period of the year. The OWTS redesign recommendations based on the
proposed construction, subsurface conditions encountered and our expertise in the area
are presented in this report.
Site Conditions: The project site is relatively flat with a gentle slope down to the west-
southwest. The Walthen Ditch is located east-northeast of the proposed building
envelope. There is a steep, roughly 50 foot high escarpment down to the Roaring Fork
River on the south side of the lot. A pond is located at the eastern end of the lot and
adjacent to the south side of the ditch. The site vegetation consists of small landscaped
trees, grass and weeds. The site is approximately 3.7 acres in size. Water service will be
provided to the proposed four bedroom residence by an on-site water well. The proposed
Glenwood Springs 970-945.7988 0 Parker 303.841-7119 0 Colorado Springs 719-633-5562
09
Joseph Krabacher
May 7, 2008
Page 2
residence will be a 1.5 story wood frame structure over a partial basement and
crawlspace.
Profile Pit and Percolation Test: Percolation tests and a profile pit observation were
conducted on November 8, 2000 by Church and Associates, Inc. The Church and
Associates, Inc. report is included as an attachment. The soils exposed in the profile pit
consisted of about 2 feet of topsoil underlain by sand with cobbles and boulders to the
depth explored of about 8 feet. No detection of water was noted during the excavation of
the profile pit; however, the potential for shallow groundwater during seasonal run-off is
prevalent in this area The average soil percolation rate was 11 minutes per inch.
ISDS Analysis: Based on the subsurface conditions and the percolation test results, the
tested area is suitable for an OWTS utilizing the shallow soils and a semi -mounded sand
filter for the treatment and dispersal of effluent. A site plan showing the proposed
OWTS, existing water well, proposed residence and the minimum horizontal setback
distances of site features relative to the OWTS components is shown on Figure 1. The
OWTS was designed for a total of four bedrooms. All materials and installation should
meet the requirements of the current Pitkin County Individual Sewage Disposal System
Regulations.
Septic and Dosing Tanks: A concrete 2,000 gallon, three -chamber Valley Precast
Concrete septic tank, or equivalent, will be used for primary treatment of sewage from the
residence. The third chamber of the septic tank will be equipped with a submersible
effluent pump installed within an Orenco Biotube Pump Vault and will be used to dose
the mounded absorption area. Sewage will gravity feed from the proposed residence to
the septic tank where the effluent will be pressure dosed to the mounded absorption area.
If the septic tank access riser lids will be installed at grade, with no backfill cover, then
the lids should be insulated with foam insulation board to provide frost protection. The
sewer pipe inlet tee in the first chamber of the septic tank should be installed beneath the
Job No. 407 0299
1.D
G95tech
0 0
Joseph Krabacher
May 7, 2008
Page 3
access lid of the first chamber of the septic tank so that it can be reached for service
should it become clogged. A high water alarm switch should be installed in the third
chamber 3 to 6 inches above the upper float position. The high water alarm will provide
audio and visual warning of a high water condition in the tank and should be placed
inside or on the dwelling where it will be readily seen or heard. The PVC handle on the
Biotube Pump Vault filter cartridge should be extended up to within reach of the tank
access riser lid. This will allow for easy access and maintenance of the filter.
Approximately 2 feet of soil backfill cover should be placed over the top of the septic
tank to allow for easy access and frost protection. For maintenance reasons, deep tank
installations should be avoided and we should be contacted to evaluate this OWTS design
should it appear that a deep tank installation involving more than 4 feet of backfill soil
over the top of the septic tank will be required.
Dosing Pump: An Orenco PF3005, 115 volt, submersible effluent pump with a 1.25 inch
diameter discharge assembly, or equivalent, is suitable for this application. Due to the
cylindrical design of the PF3005 pump, it must be installed in an Orenro Biotube Pump
Vault. For design purposes it was assumed that the elevation difference from the dosing
pump intake to the absorption area manifold is not more than 15 feet and that the length
of the effluent transport pipe does not exceed 220 feet.
The dosing pump will be controlled by a control panel and a system of float switches.
The float switches should be set to provide a dose of about 120 gallons. The actual dose
volume is about 140 gallons, assuming an effluent drainback volume of about 20 gallons
in the transport pipe. At this dose volume the absorption area will be dosed between six
and eight times per day.
Sewer and Effluent Piping: The sewer line from the proposed residence to the septic
tank should not be less than the diameter of the building drain and not less than 4 inches
in diameter and will service all levels of the proposed residence. Soil backfill beneath the
sewer pipe must be adequately bedded and compacted to prevent settlement of the pipe.
Job No. 407 0299
Joseph Krabacher• •
May 7, 2008
Page 4
The sewer pipe should be installed in landscape areas with at least 42 inches of soil
backfill covering the pipe, or the pipe should be insulated on the top and sides with 2 inch
thick rigid foam insulation board for frost protection. Beneath driven surfaces, we
recommend Schedule 40 PVC sewer pipe encased within Schedule 80 PVC for
protection. Beneath the irrigation ditch or potable water supply lines, the Schedule 40
PVC sewer pipe must be encased with 4 inch Schedule 80 PVC pipe for a minimum of 60
feet on each side of encroachment (see Figure 1 for details). The pipe should be insulated
if it will be installed with less than 4 feet of backfill soil cover.
We recommend the use of Schedule 40 PVC pipe between the proposed residence and the
septic tank, though this is not required by local regulations. The portion of the sewer pipe
extending from 5 feet outside the building foundation should have a slope of at least 2%
except for the last 10 feet of sewer pipe immediately preceding the septic tank which
should be sloped between 1% and 2%. Cleanout pipe(s) should be installed in the sewer
line adjacent from the building foundation, adjacent to the inlet of the septic tank, where
the sewer pipe bends at 90 degrees or more and at least one cleanout should be installed at
least every 100 linear feet of non -pressurized sewer or effluent pipe throughout its length.
We recommend that a straight section of pipe be installed between the residence
foundation and the septic tank. Any required 90 degree bends in the sewer pipe should be
accomplished through the use of a series of 45 degree smooth elbows or a 90 degree long
sweep to help prevent clogging of the pipe.
The 1.5 inch diameter schedule 40 PVC transport pipe should be sloped at 2% minimum
to drain back to the septic tank between doses. It is critical that the effluent transport pipe
be properly bedded to prevent settlement which could cause standing effluent to freeze in
the pipe.
Absorption Area: The mounded absorption area aggregate is designed to be 960 square
feet. The aggregate bed containing the distribution laterals has dimensions of 20 feet
wide by 48 feet long and will be constructed over a sand filter which is 2 feet thick. A
Job No. 407 0299
Qct
0 0
Joseph Krabacher
May 7, 2008
Page 5
loading rate of 0.95 gallons per day per square foot for the sand filter was used to size the
absorption area aggregate based on an average daily flow of 900 gallons per day. The
sand fill basal area calculations were based on a loading rate of 0.72 gallons per day per
square foot. Based on this loading rate, a basal area of 1,250 square feet is required. The
actual basal area of the sand filter proposed is 1,568 square feet. Absorption area
calculations are shown on Figure 2.
The mound absorption area should be installed on a relatively flat excavated surface. Due
to the potential for relatively shallow groundwater at the site, cuts should be limited to
approximately 1 foot from ground surface to construct the mounded sand filter.
Vegetation and topsoil should be removed and exposed soils should be scarified prior to
placement of the absorption area materials. Care must be taken during installation to
ensure that the soils exposed in absorption area excavation are not compacted. The
excavation, once completed, should be left open to allow the soils to air dry, if necessary,
before the sand, aggregate and distribution piping are placed. A cross section of the
mound absorption area is shown on Figure 4.
The filter sand should be placed in loose lifts not to exceed 1 foot thick. Each lift should
be compacted by wheel rolling or bucket packing prior to placement of the next lift. If
water is available each lift may be wetted prior to compaction to decrease future
settlement of the filter sand. A Mirafi 140N or equivalent geotextile should be placed
over the aggregate bed containing the distribution laterals to reduce clogging of the
aggregate by fine soil particles. The total thickness of the soil cap over the mound,
including topsoil, should be a minimum of 1 foot on the edge of the aggregate bed and 1.5
feet in the center of the aggregate bed. The side slopes of the soil cap should be graded at
a slope of 3H:1 V or flatter. At least the top 6 inches of the soil cap should consist of
topsoil suitable to support vegetation. It is important not to plant large vegetation or plant
species with invasive roots in and around the mound absorption bed. We recommend that
the topsoil cap be re -vegetated as soon as possible with a mountain meadow grass mix or
other suitable equivalent.
Job No. 407 0299 r+F �'
N
Q
0 0
Joseph Krabacher
May 7, 2008
Page 6
Combination air ventlinspection ports should be installed at each comer of the aggregate
bed. The ports should be constructed of 4 inch diameter PVC pipe installed to the bottom
of the aggregate bed_ The bottom portion of the pipe which lies within the aggregate
should be perforated. The ports should extend a minimum of 8 inches above the ground
surface and should have ventilated removable caps.
Section 628.090(A)(3)(b) of the Pitkin County OWTS Regulations state that pressurized
effluent distribution lateral orifices shall be no smaller than 3/16 inch unless preceded by
secondary treatment. Per our conversation with Carla Ostberg with the Pitkin County
Environmental Health Department on March 11, 2008, smaller distribution lateral orifices
may be allowed with justification by a Professional Engineer. To adequately pressurize
the OWTS at the subject site and to evenly distribute effluent throughout the absorption
area while maintaining correct dosing volume and residual head, we acc4mgposing to use
1/8 inch diameter orifices. The orifices will be drilled at 3 foot intervals which will
minimize head loss in the distribution laterals. We have accounted for potential clogging
of the smaller orifices by sizing the effluent pump to pressurize the system with 5 feet of
residual head at the last orifice in each lateral. The absorption area manifold and
distribution piping layout is shown on Figure 3.
All materials used and installation methods should meet the requirements of the current
Pitkin County Onsite Wastewater Treatment System Regulations.
Subsurface Drainage: No fire water was observed in the profile pit; however, seasonal
groundwater is a concern but, based on the site topography in the proposed absorption
area, it is our opinion that a trench drain will not be required-
OWTS
equired
OWTS Maintenance: The on-site OWTS will require maintenance. The level of
maintenance will vary with the complexity of the system and water use habits of the
users. We recommend that fats, oils, bath oils, greases, paint, solids, water softener
Job Na 407 0299
0 0
Joseph Krabacher
May 7, 2008
Page 7
backwash solution, water from hot tubs and other constituents that can clog and foul
collection and disposal equipment are not disposed of in the residence drains. The
absorption area and any areas directly up gradient of it should not be watered by lawn
irrigation systems or other means as the soils may become hydraulically overloaded.
Septic tanks and other treatment tanks should be pumped whenever the sludge occupies
1/3 of the liquid capacity of the first chamber of the septic tank. The high water alarm
float switch should be checked at least once per year to ensure that it is working properly.
In addition, the Biotube Pump Vault should be checked for clogging at least once per year
and cleaned as necessary. We recommend that an operation and maintenance manual he
developed for the OWTS. The OWTS should be operated and maintained as stipulated in
the manual. If you desire our services, we can prepare the operation and maintenance
manual for the on-site OWTS.
Limitations: This design has been conducted in accordance with generally accepted
engineering principles and practices in this area at this time. We make no warranty either
express or implied. The conclusions and recommendations submitted in this report are
based upon the data obtained from reviewing the Church and Associate report, the
proposed type of construction, and our experience in the area. Our findings include
interpolation and extrapolation of the subsurface conditions identified at the profile pit
and percolation test holes and variations in the subsurface conditions may not become
evident until excavation is performed. If conditions encountered during construction
appear different from those described in this report, we should be notified at once so re-
evaluation of the recommendations may be made.
Based on site reconnaissance, it is our opinion that the designed location of the OWTS
does not violate any setback requirements of the current Pitkin County Environmental
Health Department's OWTS regulations. We recommend that the position of the OWTS
components, proposed residence, proposed water well and setback requirements be
verified in the field by a Professional Land Surveyor licensed in the State of Colorado.
Job No. 407 0299
0
Joseph Krabacher
May 7, 2008
Page 8
0
This report has been prepared for the exclusive use by our client for the OWTS design
submittal process. We are not responsible for technical interpretations by others of our
information. As the project evolves, we should provide continued consultation and field
services during OWTS construction to review and monitor the implementation of our
recommendations, and to verify that the recommendations have been appropriately
interpreted. We recommend on-site observation of the absorption area excavation, filter
sand placement, pipe and tank installation, and soil backfill placement by a representative
of the geotechnical engineer. On-site observations of the OWTS installation or other out
of scope services will be provided for an additional cost.
Please contact us for any necessary revisions or discussion after review of this report by
the Pitkin County Health Department. If you have any questions, or if we may be of
further assistance, please let us know.
Sincerely,
- PAWLAK GEOTECRMCAL, INC.
Reviewed by:
Ronald J. Uhle, P.E. C.C.E.
Associate
'I,,;
V
161
��'FSS�ONAIFaG;
Attachments: Figures I through 4
Orenco PF3005 Pump Performance Curve
C)Job No. 407 0299
r-1
r ---j
IRW
OWES ABSORPTION AREA CALCULATIONS
In accordance wkb the Pkkin County Regulations for Onsite Wastewater Treatment Systems (OWTS), the
OWTS absoTogn area was calculated us' the EPA Module Number 9 for Mounds as folbws:
DESIGN fWW TI
TOTALNUMBERBEDROOMS= 4
AVERAGE FLOW PER PERSON= 75 GALLONS PER DAY
PERSON PERBEDROOM= 2
PEAKINGFACTOR= 1.5
DESIGN FLOW = 900 GALLONS PER DAY
TOTAL DESIGN FLOW = 900 GALLONS PER DAY
SAND FILTER LOADING RATE= 0.95 GALLONS PER DAY PER SQUARE FOOT
W45RMABSORIYMN AREA AGGREGATESIZE= 947 SQUAREFEIT
AB
ACMALABSORPTION AREA AGGREGATESIZE= 960SQUARE FEEr
AVAIIABLEBFDLENGTH = 48 FEET
BED WIDTH (A)= 20 FEEL
AND FILL D I_
_
SAND FILL DEPTH = 2.0 FEEL'
APPROXIMATE EXISTING GROUND SLOPE= 0.0*proposed abso tion area is relatively flat
FILLDEPTH = 1.0 FEET
AGGREGATE BED DEPTH = 1.0 FOOT
CAP AT EDGE OF AGGREGATE BID = 1.0 FOOT
CAP AT CENTER OF AGGREGATE BID = 1.5 FEET
SLOPE OF SAND FILL= 2R-lV MAXUvIUM
SLOPE OF MOUND COVER SOIL= 31-11V MAXMIUM
UPSIOPE SETBACK 0 FEEL'
_
SIDE SLOPE SETBACK = 0 FEET
BASALAREALOADINGRATE= 0.72 GALLONSPFRDAYPERSQUAREFOOT
_
DESIGN FLOW = 900 GALLONSPERDAY
MINIMUM BASALAREA REQUIRED= 1250 UAREFFO C
BASAL AREA SLOPE LENGTH = 0 FEET
BASAL AREA MOUND LFNI'H = 56 FEET
BASALAREA MOUND WIDTH = 28 FEET
ACTUALBASALAREA= 1568 SQUAREFEET
COVER OIL PROMIONS 1 V
COVFRSOILUPSLOPESETB.ACK= 9 FEET
COVER SOIL SIDE SLOPE SETBACK= 9 FEET
COVER SOIL LENGH I = 66 FEET
COVER SOIL WIDTH= 38 FEET
407 0299
G Pt h
HEPWORTHPAWLAKGEOTECHNICAL
LOT A, RIVER WOODS AT WOODY CREEK
ABSORPTION AREA CALCULATIONS
FIGURE 2
1.5" DIA. SOLID SCH.40 PVC
TRANSPORT PIPE SLOPED -
AT 2% MIN. TO DRAIN BACK
TO SEPTIC TANK.
1.5" DIA. SOLID SCH.40 PVC
MANIFOLD PIPE INSTALLED L
1.5 INCH DIA. SCH. 40
PVC PIPE WITH 1/8 INCH
DIA. PERFORATIONS ON
BOTTOM OF PIPE SPACED
AT 3 FEET ON CENTER
WITH FIRST PERFORATION
6 INCHES FROM MANIFOLD
AND LAST PERFORATION 6
INCHES FROM SOLID
LOOPED END FOR A
TOTAL OF 15
PERFORATIONS PER
LATERAL. EACH LATERAL
SHALL BE EQUIPPED WITH
A FLUSHING VALVE.
SOLID 1.5 INCH SCH.
40 PVC LOOPED ENDS
ON DISTRIBUTION
LATERALS INSTALLED
LEVEL.
4" DIA.
PVC AIR VENT
INSTALLED VERTICALLY -
TO BOTTOM OF
AGGREGATE BED.
BOTTOM 12" OF PIPE
WITHIN AGGREGATE
BED TO BE
PERFORATED. TOP
OF PIPE TO BE
COVERED WITH
REMOVEABLE VENTILATED
TOP CAPS. INSTALL
TOP CAPS A MINIMUM
OF 8" ABOVE
GROUND SURFACE.
NOT TO SCALE
2'
T
0 0I 2
�-� 20'
NOTES: 1. ALL PIPING AND INSTALLATION METHODS SHALL MEET PITKIN COUNTY
OWTS REGULATIONS.
2. DISTRIBUTION PIPES SHALL BE INSTALLED LEVEL AND IN LOCATIONS
SHOWN ABOVE.
48'
4070299 I G(;&eCh I LOT A, RIVER WOODS AT WOODY CREEKI FIGURE 3
HEPWORTH-PAWLAK GEOTECHNICAL PLAN VIEW OF MOUND ABSORPTION AREA
3G
Pump Selection for a Pressurized
System
LOT A, RIVER WOODS AT WOODY CREEK
Input Parameters
4070299
Orifice Size
1l8 inches
Residual Head at Last Orifice
5.00 feel
200
Orenco Systems
Orifice Spacing
3.0 feel
------
--_--- -- _
Effluent Pumpsp
Incorporated
PF30 Series
Number of Laterals per Cell
5
_
112h to 3/4h
Lateral Length
44.0 feet
180
Lateral Line Size
1.50 inches
PF3007
814AIRWAY AVENUE
Lateral Pipe Class/Schedule
40
SUTHERLIN, OREGON
Distributing Valve Model
None
150
-
97479
Manifold Length
28.0 feet
-
Manifold Line Size
1.60 inches
--- --
Manifold Pipe Class/Schedule
40
Lift to Manifold
15.0 feet
140
--
TOLLFREE:
Transport Length
220.0 feet
_
18001318-9843
Transport Line Size
1.60 inches
_
Transport Pipe Class/Schedule
40
p�e
120
Discharge Assembly Size
1.25 inches
G
PF3005
-
TELEPHONE
Flow Meter
None inches
a
_
(51114594449
'Add-on' Friction Losses
0.0 feet
=
100
U
Calculations
_
-- ----
FACSIMILE:
Minimum Flow Rate per Orifice
0.43 gpm
>.
_
Number of Orifices per Zone
75
0
80
1541)459-2884
Total Actual Flow Rate
32.5 gpm
o
12
Number of Lines per Zone
6
- -- -.
% Flow Differential 1st and Last Orifice
0.4 %
60
www.orenco.com •
Lift to Manifold
15.0 feet
-- --
Residual Head at Last Orifice
5.00 feet
Head Loss in Laterals
0.1 feet
40
Head Loss Through Distributing Valve
0.0 feet
Head Loss in Manifold
0.5 feet
Head Loss in Transport Pipe
13.5 feet
'
Head Loss Through Discharge
5.3 feet
20
Head Loss Through Flow Meter
0.0 feet
'Add-on' Friction Losses
0.0 feet
00
Total Flow Rate
32.5 gpm
10 20
30 40
TDH
39.3 feet
Net Discharge, gpm
APPROXIMATE EXISTING
GROUND SURFACE
1
NOTES
1. AGGREGATE SPECIFICATIONS
STANDARD SIEVE SIZE
3/4`2•
No.4
2. FILTER SAND SPECIFICATIONS
STANDARD SIEVE SIZE
No.4
X PASSING BY WEIGHT
100x
0-20X
0-3x
x PASSING BY WEIGHT
100x
EFFECTIVE SIZE BETWEEN /30 AND /60 SIEVE
UNIFORMITY COEFFICIENT OF 4.0 OR LESS
3. CONCRETE SAND IS TYPICALLY USED AND EASILY
FOR FILTER SAND IN THIS AREA.
4. TRANSPORT AND DISTRIBUTION PIPING TO BE SCHEDULE
40 PVC.
NATURAL SOIL CAP
1 FOOT MIN. SOIL COVER
WITH A MINIMUM OF 6
INCHES OF TOPSOIL
1
11 e e a n
2
I �T 17 I 1
I � � I� �—
�-� �
2 FOOT MIN. SAND FILL
WITH GRADATION AS
SPECIFIED BELOW.
MAINTAIN 2HAV MAX
SLOPE FOR SAND FILL
MIRAFI 140N OR EQUIVELENT
GEOTEXTILE LAYER.
GRADE MOUND COVER SOIL TO
DEFLECT SURFACE WATER. MAINTAIN
3H:1 V MAX. SLOPE
1 FOOT MIN. AGGREGATE THICKNESS WITH GRADATION AS SPECIFIED
BELOW SUCH THAT 8 INCHES OF AGGREGATE IS BELOW DISTRIBUTION
LATERALS AND 2 INCHES OF AGGREGATE IS ABOVE DISTIBUTION LATERALS
REMOVE EXISTING VEGETATION
AND APPROXIMATELY 1 FOOT OF
NATIVE SOIL. SCARIFY GROUND
SURFACE PRIOR TO PLACEMENT
OF SAND MATERIAL.
Gk�'Stech
LOT A, RIVER WOODS AT WOODY CREEK
ABSORPTION AREA CROSS SECTION
APPROXIMATE SCALE: I 4070299 I FIGURE 4
1 INCH = 5 FEET
Apnl 6, 2001
Semam Bugg and Design, Inc.
2088 East Main Street
Aspen, Colorado 81611
;6 ages, Inc.
ENGINEERS & GEOLOGISTS
Subject: Subsinface hrnstigation and OWS Design, Proposed Residence
Lot A, Riva Ranch PUD
Pitkin County, Colorado
fob No. 13207W -A
Gentlemen:
> ' As requested, we have investigated subsurface conditions and designed an onsite wastewater system
(OWS) for the proposed residence. The subscuface investigation was performed on November 11, 2000:
SITE CONDITIONS
The property is located in a residential area in Riva Randa PUD, Pitman County, Colorado where OW$ are
...
�:. raNirod. The proposed drain field area has a 2'/. slope to the northwest and a thin cover of native grasses
and weeds. The residence will be served by an onsite well 132+ feet fiom the proposed drain &4d.
PROPOSED CONSTRUCTION
aI=
A four-bedroom residacce with an area of 58M square fat (SF) is proposed at the location presented on
F•>•.' Figure 2. The OWS was sized based on 4 bedrooms and 800 Gallons Per Day (GPD) using AspadMdn
Fzvronmental Health Department (APEHD) loading of 100 GPD per pecan. The sewage loading with a
pealing factor of 1.75 is 1400 GPD. This loading includes washing madames and garbage grinder.
SUBSURFACE CONDITIONS
A subaufece investigation was paforned by digging three percolation holes, 29 to 34 inches dap, and one
profile pit at the locations indicated on Figure 2. Subsurfiace mmtaWs in the profile pit consisted of 2 feet of
topsoil, underlain by sand with cobbles and boulders to the maximum depth explored of 8 fat. Percolation
tests indicate percolation rates of 8 to 13 minutes per inch (MPI). The average percolation rate is 11 MPI.
Percolation data is presented in Table 1.
RECOMMENDATIONS
The installation mai include a septic tank aod:thtee ahaial5ar ype drain field beds installed at the locations
presented on Figure 2. The OWS de* is bird mast sewage load of 800 GPD and a percolation
rate of 11 MPL The installation mast inehadsfioe'20tvw-watt, precast concrete septic
tank with an effiueDt filter on the outlet i6 tit ere dnolbe AWe two with three rows of five chambers and
(d r one with three rows of four dnambas A Saw"splitter >ritm is required to distribute efbient to the fields. If
gravity discharge cannot be achk"d oar We ahculd bi;'ooatacted for specific pump details.
DENVER 4881 Wadsworth aouAvard Wheat Ridge, CO .0033 CASTLE ROCK 303.860.4358
ti ; .. - 33.40.3.9317 Fax: 303.1834321 EVERGREEN 303.818.1455
9 " ' LOVELAND 970.6832124
3-�
• Subsi* Investigation and OWS Design
Job No. 13207W -A
Page 2
Vehicle movement over the drain field area during construction should be kept at a minimum to
prevent compaction of the receiving soils. The bottoms of trenches should be scarified with a pick,
shovel, or backhoe bucket teeth prior to the edtlSt M Of Chimbers.
The surface of the field shotild be seeded after instaWon of the fields. A native seed mot available shpuld
be sown over the trench area These mixes do not require irrigation and develop a growth 10 to 15 inches
high No automatic sprinkler system should be installed over the fields.
OPERATION AND MAINTENANCE
The owner must realize an OWS is different from public sewer service. The owner must be aware of,
and assume responsibility for maintenance of the system. In the absence of a monitoring program, the
septic tank should be pumped every two years. Eluent filter and screened vaults, as applicable, are to
be cleaned during pumping. There are daily considerations such as not putting plastic or other nonbi-
odegradable materials into the septic system. Garbage disposal use should be minimized.
The backwash of a water softener may be hamnf it to the OWS.,A separate drywell should be constructed
for the backwash waste, if a softener is installed. Chemically treated water from a swimming pool or spas
should not be introduced to the OWS.
LEMHATIONS
An OWS destgrt should be installed by a contractor who is experienced in its installation. Our investigation,
layout, design and recommendations are based on data submitted. If subsurface conditions considerably
different from those desrn-bed in this report are encountered, we should be notified to evaluate the effect on
the proposed OWS. If the health department makes modifications to this design, we should be contacted to
evaluate the impact on the performance of the OWS. The county and our firm must be contacted upon
completion of the OWS.
All construction is to be in accordance with the ]SDS regulations. Pipe type and size, burial requirements,
septic tank construction, and other specifications, which are not depicted in our report, are to conform to
the requkonents of the ]SDS regulations. The installer of the system is to have demonstrated knowledge of
the APEHD ISDS regulations and requirernerrts.
Edward 0. Church,
a ^.
SCALE
LOT A. RNER RANCH SUISOMED
PRION COUNTY. COLORADO -
wnDAT ON DITA /
651 SF OF rFwTxAM r�A w ns� auvr� Less /
\ AND BEDS'A' VES ROWS OF 6 04AMMM
AND ROW MTA
74 VES ERS. OF 4 CFWfSERS /
/ `♦ FOR A TOTAL S1F �2 GYJBHtS•
FLOW sru / w
I /
SEPTIC
ENVELOPE
LIM FAST BE
ENcesEn ` /
1 AccaRmNE ro 82•
1 �DLiAnaNs X01 /
I--- oira — —
2000.GALLOK
1 TWO-cawARrnwr. I
PRECAST
1 CONCRETE SEPTIC
ITOM WITH Lrd, I BUILDING I 132' FROM
ON THE OUT Ed ENVELOPE WELL
1 JPROPOSED
�
\/ If 1, I FWELL
RESWEKE \; ENVELOPE
I
\�I
1 L-
1 LOT `\\
I5.9 ACRES
1
... ,
. IRRIGATION DITCH\
R�gRING
FORK
RIVER
... ..............
.................
...............
SITE PLAN. LOCATION aF
PERCOLATION HOLES, AND LOCATION
OF PRDPOSED OWB . . . .
JOB NO. 13207W-A . . . FKXM 2
- N.T.S.
CRAV}LlESS CHAMBER
3' BY 6.D'—
4' WR 35 PUC
OBSERVATION/VENT PIPE
4' SDR 35 PERFORATED
PVC RPE PLACED ON GROUND SIREACE ACCORDING TO
MANUFACTURER SPECIFICATIONS
(PIPE INSTAUED LEVEL)
TYPICAL CROSS-SECTION - 4V.� VC PIPE
ROlVATIA CAP
1 4' M" /
2O' MIN.
EXTENT O M
CALCULATIONS AND SPECIFICATIONS
DESIGN L7VTBOA
MAIN RESIDENCE - 4 BEDROOMS, 8000 SF
LOADING - 100 GAL/BAY/PERSON
AVEIRAGE LOAD= - ICO GPD
P00)LATIH RATE - 11 W
AREA - (1.75 X q x-417/5
MEA - 922 SF
REDUCTION FOR USE OF CHAMBERS - 30S
TOTAL AREA - BW SF
JOB N2_13 -
J 'B' LEVEL MANIFOLD
TOTAL - THREE BEDS
4' SDR 35 PERFORATED
PK PIPE PLACED ON GROUND
O AVELL65 CHAMBER
7 BY B.IS'
BED SPECIFICATIONS
NUMBER OF PUSS - 3
LENGTH OF CDS 'A' - 31M FEET. 5 CHAMBERS
LENGTH OF ® 'B' - 25 FEET. 4 CHAMBERS
=71,1 OF EACH BED - I FEET, 3 0IMW6
TOTAL NUMBER OF CHAMBERS - 41 CHAMBERS
TOTAL AREA - 551 SF
DRAIN FIELD DETAILS
4' SDR 35
SOLA PVC PIPE
(SCHEDULE 40
UNOEA DRIVE; 1,/I'
PER FOOT DROP)
N SPUTTER BASIN
14/30 - 3 CUTLETS)
--�_ETFLUENT INLET
(1/5' PER FOOT MOP)
nnw�CUnysC m�wnn
IDME
OR9FILtx r mwiPw
miwnw
I1�V1E
TREATMENT MIT SPECIFICATIONS
MINIMUM TOTAL CAPACITY - 1.75 S q S (30 HOURS/34 HOURS) -
1750 GALLONS
70OD-GN1W, TWO-COMPARTMENT. PRECAST CONCRETE SEPTIC TANK
MIDI AN EFFLUENT FLTET ON THE OUTLET
CHURCH & Associates, Inc.
Septic Tank with 4" Dia. Biotuber Effluent Filter
2000 -GALLON TWO-COMPARTMENT PRECAST CONCRETE SEPTIC TANK WITH AN EFFLUENT � Spks Ba w/Cad G*
FILTER ADDED TO THE OUTLET
F7tr cww*
Nutabe Effluent Filler or Equiwlent
F f j 4�, 2 5.44 6J5
PwWq
elm, &wwo wolk Inc.
JOB NO. 13207W
FIGURE 4
Car✓wW Lid ■ahswklfm
er♦ mm ASK
Bella
Gmund
PVC %w wb Gmnwno�
YAWN 6 OR=
gs7Feol
•
Fran n Rev
---
sari
reeamrwded )
ad
Tank Adoplr
to
F1ber Crtridpe Horde
74lF1rOC
(K1) 4W-4�
(� r bA4
AContka kam F
(Heid eut to deelnd height}
FACOME
Co" Sed
(ett) 40 -SM
„
Took Moptw (cad or belted}
InWt Tee
Ment Qtiice
Lod
-i
r
Whim
vad 1Wd Ports
nod
F7tr cww*
Nutabe Effluent Filler or Equiwlent
F f j 4�, 2 5.44 6J5
PwWq
elm, &wwo wolk Inc.
JOB NO. 13207W
FIGURE 4
ProBie:
TABLE 1 - PERCOL AXK* .TEST RESULTS
LOT A. RIVER RANCH PUD DATE OF TEST: 11.1-N 1
PITKIN COUNTY, COLORADO
DEPTH TIME DEPTH DEPTH INTERVAL HOLE
HOLE OF HOLE, INTERVAL START, END, CHANGE, PERC PERC•
NUMBER RATE,
(INCHES) (MINUTES) (INCHES) (INCHES) (INCHES) RATE (MPI)
iMPll
2 33 10
2.50
3.75
1.25
8
10
3.75
4.50
0.75
13
10
4.50
5.25
0.75
13
10
5.25
6.00
0.75
13
10
6.00
7.00
1.00
10
10
7.00
7.75
0.75
13 13
JOB NO. 13207W -A
1 0
•
FIRST AMENDED FINAL PLAT OF PITKIN IRON/RIVER WOODS PUD
[ER}RCATIgI.1 CEgCn}ION ANOOWMEA9NV
ozr YI Innma nY IMee Pnvanu INat I"' RMR OEVELOPNEM. LLC,, Cameo
Mmxee IMOIIk/ eomWnY. tlellM Ue
-..10 .. Ynee M I. Colmn, Coblaeh.
JescrlMe Y blloxe;
PIiNM IPOWRIVER Rp I., Neombp Io DeePMI R,,,W IeeorMtl Mxeb }],xWvIn
IW.e fax PgenenJ M.
EICEP}OUZTI PI MIFUN:PNEp IeH,, PUD, Nedglq la Xn PW XIwM
-IW. Mertb R..mPl. ,"N Pape Ex
T.G Tll.n YKII. I rlpnl W,- antl can.. na., ena.<mp PRYIn Ym Rvtl.e
C.W. glee ftln e,No.4x antl Pwr:ng Pmcb Roaeb Plrer peM,NNlwnwIM
al PIIFIn ImNPlvn WwM PVO, accwJlnp., Ue Plel mored recONatl NNa# x3, 3pW
I
` ponyrzn Vea.el. ane. 1W1— In PPXb bmf Ewam. n. recoreM xwamMr v.
1991 W, N.cewrnn xo. MScµ.
e`el anr.ne. Un IIMI PUI d Pexin h Rlra. Wmee PDD a. mornon IM I.
nIr OD1e1 Waae. PUp ane ewe In W, tlMkele. mn br m.
u aI Nnom.e meY . 111c JYl .W,M ., Uen .We,.X_eM•w
n.wrtl mW ega�l.,.f ]e%.
PFIYJN Mpl OIVILOPY6ai, LLO.
A I;awNd WWy bMryv PM
T rl Mr
pTAREp1.GEg4➢DI
CpM}Y OF %tNNI NE
RW l.rgoln91ne1rumanl was acYrotl MI
31 hY mMngr .1PlUJ.IpR DeeNLLC.
ry vlVuu eMb
eU.MY
11
mYW. Mne.n MI -N 1
My �omm��-it'OM
~��Pnak rl d
LFNMWS 1 ON KT
OKIV¢1D pA1Ml At Te..1, as ele W.W111a1.1Uw eanW eeeWe W Irv...
newbe 1bIN A'b10 Pl RNMbn Ne.. YI41 end Y13W, me U,1 eeNul Fln.rl.lnP
%emltl.e M.la 33, KPe N Ree.Plbn No. YI'Pe, encurnMlq e.e nenm
eaOQR4 Rtllbe nel a PUD cWenb b Iel 1.c 1.1 aUn FIM O.11 M FlnW PI.1
a RYN NNMNw Woab NO eMfelM In Yb WdkMbn b Ihe,111m1 elle Nnml
tivNe.
,W,Yp Nb d;: 4ya /1'F. .3001
Re: W @lD IRM, M TRIN3 C OIpANY
pr
b: rL� L�Cr �uY-•3L.L•
mm DP Llja,.y3. �J•3-L, J
49
CgIHTY OF i�y�IM M'A I
Tl.p.yPMp3a/PM1 GI.eM.p. Nylo.kep.e M3wcmebr
U i anleeaLD eAxNarPuscawAxr
ew. so aFa aria/ .3wa
r___-��r � a zt•
CIEIU] PEp IHOMOB[SML9TMQ NR IZCOP W G
Ttl. FbNMm1140PY/M13a{1Ye Mn.Aew WWYNOeaRepW'UR tiv
alk.an. CMnr r c+wrp m.
oWdy ,IRO,
mbt,nnrebr..� +Pqn res PNM ccwmNebMl.
MaNbn %AMiEE. ANeN4peaREw E,
(::�tYLNL+Gf" -155
pWY.le Rwa0.3 �J
IwlaMec FI
Uwpun Y�w�IIYrwIDSoUItrheeyO4VIerIi11J�tWIe M tRW rO�emn°�1l7 vMd
01 -Mt _.... Wed 0.7Ynw J.po.onr
.
ill FbN Pnr,M,e FYr,I PYr,I P:ym hn:vRlr..w ,P11p la aJWIM PXYIn
ewnn pv.w a ewMv ewre,n.W can a. a m. JE __ mr a 3wMu.L-a.N
TMPWncaoMy Be,q acwmn C,mmM.vn<n,,e m.nxlelkfurol
aorarnr.l n<vbe W leX a3, Mpou Pxao.un Na, ..i<..
.b Uwnxa ..u01 AI.•yn.d�>reyMfuoel. Ail l All.
m.L.Wllm.mlrmr^bnRrI..m..0OWeeW. owe.1.1.1
cMdeneNL PIWr Imxeacewrb.bnx.�
SEE
PPp _l n:napwvvNofrMFlnl AM,neae FInNp!mnl PtW,J NRlIIWooe<PUO
by PNFin Caon1Y, Co!or.M<eeluQv aYpmval PI U,..... anl, ene mael(wlbn,1.111
YmY %a1 me 9il<3lp«111 D,r,lnpmem Plvn of Jle PilY,n hMplvx Wohee PUD r<coNM
.rtµ II. xcoJ.l„ P.r pnN e3. W Pap. ex ,ne ea, n en.wn Mnw, }nM Flnl NneM.J
Fiwl vkr nr pwm LnrMlv.r waves Pup n.rMr.. p..wly .cam.:
lel In :onp4•albn aml wcalion al U, purtliw Enr<Iopa.lne WW Emabpa,
I<1n 1-ee nn Pnx W.ne, L.ra A. e. Cxq Dmb.
c n11Yur hon„ne boJom a, anwn Mrcw,
Ibl o'Jon.:Ne publk OIYW9 easwuM nPI1YM Yo^
no to Op<n DI- 1., m .n11PuM n,M loalbn o eMwn M on,
Ia IM propoxU rabcalion ollA, WNUm Dlkll: punwnl lv IM1i, am,ntlm,M.
all pe n. ngUlrtmml w commlJlxnl olOwnx b m.r, vM rehc,W
IR. w 1111 Dllen. Is<. Nor d bNw.l
Idl b, I.rm a m, Plp I, cMlgw m PNI. ImNarx ane Jre _W
ame FU< g h p.Ml<Mun.elm Ow RID k eNrq,d b M,r W.M,
lel Un name a -o Recall Read wMe 1M IUD a cnanq,e to RM,r Wocda
Regie.
AU d,rWpm,nl In Rn P. ".- W..S PUp-.-IeW.I ;. IM 4.W isbn
Ynme1-. Apna W br Rum lIeeRp.l Rena PDO r.cre<e .-hu, 3p.
Re<eP1xw1 No. Yl le, wM w. Flm nm.,w ,O I. be sU.0 nW n enpmrem.n W
Pgramlenl
.
r.d 11T-<^03001. ae Pe[,PUen M.. •L{fjpLenblN IMo MMeen
m, p.rm.M Rum cm:n ed le pwem.eWb, Rwn uenRWx gam. IUD M. 1
C.r,mnu vne PlannY Und pwelo0menl Guk,1µo11.1 Wnh 3j 1W0 Y N.e,Nbn
No. 4153. and X�111.Few Pm,nomenl Uen.n r --We OdiL3/ xMl,mgx,plbn
N..4 <GOP�lM' P•JD',We'1,nrerM:d.-w IM 0µ11r,, PIIFIn Co.n1Y.
S. C.mmn Own epac,c ek
P.Iv,n !Iwr.zMllMpermamnlly
we. erbxn ",ge w panmp. anw.1.191 and.U.in
apalw I- U,e.lUt .,ewnpxaarwcnvd,n no dl il.I. wc Un ne -W .10 U, h11µ wxe
mryM,Xoeee Uy M, PV. Gubs. Cemmon Op.. ep.c .I E. Mver Wowb eMll h,
Perm,In 1n ted b.. a I« w11 an. w.ur....a. PP as w."np111W.
rnmon vpn .pec,, r eeelonm.pen apce all 1.1 aP.cWWrel p.r,WW; 1,1 IM nnnNe
M IM --ee ontl r.am.nn OR'— Woeea me 1. U. s Olnr.ees ae mvy U. vlbwe. Uy
De.
PUD GJNe.
3. V.. W.m. AWm.M bn MlAm,nMd Fhe. pbl.I PiLLIn.mNFlvx Wmrn
PVO M PIUrb Conn nor --r. I'll, rpnu punuanl;. ANcn 52 T4.. le.
C.bneo R Ree` Slbhw ane p.m ... t;l m, pr.rnl<m.In, Plrem Conry L nJ Ue,
c,We
I , WNIMRONch,3 Wn
,Jpn<n 1, N.wn on ll.b 01.11 Owner
Mrehy -e-e"' lo^Ueabenelil el WWW PiuY. I—,W Iha oNx canon of ln,
W.IU,n Dlen a noMell lr.e W-1 IDba.m.. bD m1. es em...... cl
WW.0 q e_t.WWe v1U, W.Men D:Ich, forme P.Iwaea of <errylnp IM weln rlpld,
p ,.enpy.,else.m U. W.IU,n Ul ane roM«n I. U. WellMn Oecn Ior... e..,
Imemc. aN npalr d me weM,o DIKn. 3nN Rr.urr..r.e,e 1-1 11.1 d Je PUNn
DWRMr woM PDO her.e�ee%eun nk .1, res rcanmlhn
pyn,r +M r.Ysep ,WNInn WU m mporen,ne. Mmo,
aneh exprve.h. W,.enMme f.r WWnrl mw.
e. pmwrya, tM •bnmy wee�..ele.-n, .1......Me..IW bte f.r ewe,
W.N M,-. LW A.. C ell OIL Ue rq.I,M-W, brIM em1 b,ech
a Ree puilmp ee. I, DmweW-1 ^of U. bub. n,nYdMrleewrorn over Pe
Ames tlW Maln9 ew.lnw ucM le the M1r,wey,nx x d„IgnNee m Une FM
ell fleeI le m Rub Y mJRW.r WOW. IVD.
e.Pud Ewce xn ERN,.i w. -Med W IN.Fnl dm,Mee F PN .11 1.
JOeR1 ,Wore. PDD U. IWW PW a P.n mNRlvx Re. PUD a recerUM VWeh 31
]oDp In %.c. W a Pep 43 and M.M NI ume, pmrbbnn.bllpWwn,.werlerW,
ru4k Yme e W YI o10µ vWlxs s.l bU Uerew.,11111 In 1., brt. aW exec,
7. PUkW on e,n.o.Nnime Common 11111eµ C.mmon.iv. : he Cone.m,....m Map of
pNYn Uon recoI %,evend,iWeFpM B.eY seN.weeeWW1M CeMwre
pxlayMl.r PlMlnbneme Lnwrye3ph1xRx ebmnl Co,piax pw,O
eefim µM dunrM U, PWem IrwrCme,mm..m,i7 POM 1n CeeIeW
Lme 1. 3, e. a. a µre 6 gird e,mwn Ly,n 9q<. L.. :. 0µµm N,e. Tlm FMf Am,naW
.MI PMI. PIIIW.I
meq lr xp•, nd Innnd,. ro aRn(wmWllY In.rrY w,y
YN CmdomlNum y w C,eWWW'.WmnAoun JeclxaYen.
HIRED GUN SURVEYING LTD.
P.O. BOX 9
SNOWMA55, COLORADO 81654
(970)923-2794
LEGAL DESCRIPTION
TCOE1NFR wminurcERTANIquFxLLu4.vE MXLFIRFQIn�II@ D.EwPtwll.
IyMtgµl2 MDgryN11fFM1 D]S1M NIBLICRM'AYAY Xr:pMlb 111E FlINIn INpN
pipp4N3AF WJ11E PFRIIC1dMLLYDF4CI10EDNnWrfFR}NNpRXN 01011 FI9Ef•ENLrM1pN
ETNpI CMMfYPECV1GF01qIENiF1 .1.IpEEPB PFCF➢}Xa1 Mx.a3aA] NiXE OFFFICEm�
v ne mmN m1411r .sal Ma p3nolm Fn.
MRNOWM
M XVONPx.Vp.Rccwemgb Na Prat U,r..l nc.NeJ Mx<N :3.ZWO:n
P.ed+ m.1 .1 1. P.w n .xb u.
SURVEYORS CER}F ATE
Fa e,npnl I wIMW eltunae.r.w,.. a..1U0 1rn . b:
P�wree nM IMI drn.r.eW I,nm Ral Jr vaen. wawr.r wore. vua n a. n.1«umn d
M,ry. rolls ane elver e ..v 1Ml
lea... vn a cly:na comcllY snwn
•ne II
_O_m .� Ihw„raY,a m ne 9rvuna
In w.ln.sa wnar.al bW.aMmy hall elm savl Uia Jay.1 �, 3001
ca. R. Caraucnx.PLi.L iN.�M]Dl
BEEI
@rrf 1M Np Mr WRS
Ogle
FW t.r4®M®aW1Mi
Dex SU0.VEYPD: III IM, "TA%3E RARE: 0010305
DATE DMFtm: ✓M. 011AWN 9Y: T. WN%
mlem: 3LoucD
REVISED: 3/mol REVLSm PLLE IM MEj Rml Mt Pt_C,C Pap 3
FIRST AMENDED FINAL PLAT -OF _PIT_KIN IRON/RIVER WOODS PUD
FINAL PUD AND SUBDIVISION PLAT AND SITE SPECIFIC DEVELOPMENT PLAN
FOR PITIDN IRONIRIVER WOODS PUD
PITgN COUNTY, COLORADO
NOEE :1E0NmIHO 11E NW gIOW N N R INN Ppi 4YlOB8 W O 6A8EMF.Ni
@WL'NBiTE 1ECM000MR1 MRigNCWNT'ClF]lIt A10 PEC0110EM1N
1E@IpNN0.epEWr AMa IIEI'B11a11 MOpeNf. rm'mro MSE
ooc1EENA 1Efa1E EWEEwwnwlmlltllcllow � \
RIVER
ROAD I ,
\�
-- ------------------------
R.F.R.H.A: R.O.W.
.IIYgC IY.q
-----------------------------------------
�.
•n•ggt yq
aEq �
In.IAYMgf. �� —
♦......................Rill!]FOf.A�¢EAE_iiE EAed�liM1M'fitp6Y ---
------------------
ff
9®®
,�,,��yy��,,rr �Wnq[IP•IAEI�•.EwNtliwgw`.ee..n
e,nY,r�EEw W tiaYmN[.,I.w
.ores , r :a1
♦^ —_—._
i .- •--tl�. .- E 6Q 1
�_.� - �- RrvHi WOapE bTE
L1p ACIEH.4
p[A.w NVERWCCCB tATC
Emn At2lFE.s-.
wrA
RIVER
iL nru.n .. q.l a
/amu•
Pq A
•� •R0+148+®
NU•619PWIEaNWAY E4 0.0.W.
W
N.W. ECIIM
mE®EaEErnwE
—..mjw q
•
FORK
" .A$ I' ft
COLORADO STATE HIGHWAY 82
CG•[
we[a—v Af�u.•�
W -42 -JM
En..r
�A•.2]Ely NNN M•AY Ei 0.o. W.
HIRED GUN SURVEYING, LTD
P.O. DOX 9
SNOWMASS, COLORADO O,G54
MO}E: PE6Egl0 MMEA MFFEMIm MIB'Al}FJ1PY.}E ACCEE6
N?= woAi NAa rMEMFHr rEca+neo vnm
W.xen]a]Na.EaEv No I�srlor]woEre. nssEN }o MSE
oocu®m vaE SEaExIa Am mremucrloN.
eaa a neE}E.
feta wwwrnx
a .NEtin
wD
.E R61 C0•xFA wYn uwvx,¢,¢pry,
/ LEGAL DESCRIPTION
p WN
��M
}NE}IEA 1,Ni EEmuY NONLt0.115ryE E.Vp®IfEpIMNE ggU]gl.
to
N
iiEEi
I
41g56Yp AS EbPE5iM1�CVlMIV 1]ESCflBEp MTT X11}ANmMN pgMNd�EWiN�f pNN
M AwRNo i onN w.l�nwn N«u,nc w]Nwmv m M eonm oP mwn mrEN 01EAE
oemoN cmxm nevr,.e w�.e.cw Ir, wqu NEcsrwn.u[as nM Sre1cE
aP M m xn caxnr aEu um NSmNoex
ANp NNOWNA]
E
Pmtn IRONWIVEF MHCN PVep[mNinp b N[ Pln N.nW r[[orhtl M.r[II li ]UOO In
2'[J
5
PI•l800k EE n P.ge 9].nE n,
Legend and Notes:
�`�
I
exv..pegpr[q,reeam
vn•.rq r.Mru[ppu
ww
e
exrlgvw
s—
,wnnaa
�NEIaIIE
--�—ag4fw VRmw
RE
DRAWN BY TOM YOCUM BOX 9, SNOWMASS, COLORADO 81854 (970) 923-2794
MWE11111E]� M
n'RANIER M MiA ff£tWlt n,P,[1
Iq.! ppq IeVI®Puw1E qw Pyi Rlq']
0
v`
Srl�p•+°
1
1
1
1
I
1
1 S
;o
1
I
•sent
1 Si•,M
•y fM/
_ 1
arty Bba
E
f
FINAL LANDSCAPING PLAN
Scale -1'.50•
To rA f NrM TEHUL
PI[N PNyny Glavn Colm.+'^ •-iveel
9'-10'e•n.7gl61 rol.0
PppuM1U TrnrrubNlef 1^�Mrrhe[,I 1
r mxnm.rrr �an„n. rwl roi.r
mMMr-um
ropuxe,ieuim,e.alHperKM26
re•I cnHanwooe f
3- -361aa1
NrrelartltlerrW rHo9a ISnYKeOnry rl. upl
35 wlwl
IIORSL' PAS•rV(RC
SEEOGo I12ER
srrlrr esr e.o.. se.H r3Ec
Ilaelllm.PrYHwr11Y1
-sHwTr.^rrr��
-19M1wYYIVIww9. .
-IEw-Ilq�'e�eEr YHs
-rw.e.aldntiwrbP4
orrrlpeararaer.Irw Er
�rirHMrHi4
S glyy. 1
5-(�ALE
r�fLOPE t
6
pEp,Lnr��.rN cr.r,r-'rY ■ . 3 —
.µlc
j{oAKINlr R,1,.cH jZUA0
(SeW F M,.I: ., •ysrwi • .8•r.. Ilr,.-r aw. . t i
eW - i Elle
VeLL, n • 5 • - / /
ENJ � 2 '�vjj' lvf•r_
I J/
1 1 �-
��7—
—t
TO
e iLNi 1�r• 1 L:G EW M /i
7 ' N•+w"1 1 5w6 LrvV 3 / LsTp • J . �/
,y _ ",N +b4 +µ �� O=M•N VNEnTe
l •,t HAMM r
^lam E E Y flif Pl 1 RIVFR WOODS MI«IN.N TRfrl
r \ Ewltrre.a = E
r CNTtw.Ke.o- z, Z
cr rlsft N= `3 a
_-$FAv,cEnEPRf
i illfifs: 20
KDARIIQn FoRr RIVE2 Alf- BERe+s L`Ir
M y.
Moir
E E
E
e
3 Lan vrc
OL
S EtiA � Z
0 86M' gE.M` 's. �w+p
L° LNr
«5
Rw1n3.a.cF.,,,• ,�7, L
A�r� A IQoN n Y y.f� 17 EEPE0
f�nc
� Ay 5° iso FrE<o c c_z
k / 5 f, o
C'�yf3 � SePTK "
SfeiLO F,EL rJ
fN , WEGI.I
^ n KrN
i FxST1.rE+E /Jure' WRTEQ
SIn���``I�ILY IRox• $AINe c,/G APPR ux IY^N` STOQeE�
PLA r— Ago,-.•wreb O Loc E rs^r oTEO.
\\w�J pl.n«nw rish., n 39 = �•� vnL PLR<E.,Fi-•
SERYKN•GNI{ MoT VAP)
K:11 PARKINIr
1
EPM"u,r PLA T,r lr
c eTrx«.re.o7 6
24.
5�r„N.e.rrT Is
U
z�
c O
ra
W ° `0
�a
zLn =
OQ3
C
Y n Y
N s
z�
li-yr
a
c�
1
HV
onwbw
LANG tf� fl«4
PLt^
,
SO,,E
WIT" R-ised
Shut No.
9�
A0.4ji
0
`-1
•
5
of s e
•
CA
1.18.07
•••-
8
�r�now�an�n tio�u
oo+wemfe wrzw®
KRABACHER I SANDERS PC,
ATTORNEYS AND COUNSELORS AT Low
B.Joseph Krebacher
Curtis B. Sanders
Jennifer M. Causing'
Diana G. EMinger
Robed S. Hoover"
David L Hailey
J.Patrick Boland
' Am �YiYY1nIM ra.iau..wr
-sue anme�aw
�seuHti a�.ycr.a am
October 11, 2007
Jerome Pmiassionaf Building
201 N. MILL STREET, SUITE 201
ASPEN, COLORADO 81611-1557
T(970) 925-6300
F(970) 925-1181
email: krabecher@krabacher.com
Internet:w .krabacher.com
Pitkin County Environmental Health Dept
HHS Building
0405 Castle Creek Road
Aspen CO 81611
Attn: Carla Ostberg
8. JOseph Krebacher
Ikrebanher@Umbecher.com
Legal Assistants:
Cheryl M. Helberger
Shayn D. McFarland
Re: River Woods Lot A
Pitkin Iron/River Woods PUD
0200 River Woods Road, Woody Creek CO 81656
Dear Carla:
Thank you for meeting with me yesterday along this project.
I am enclosing the completed application form, building floor
plans, land use development approvals, and proof of adequate water
supply.
With respect to the well permits, you will note that the
permits numbers have changed. This was because the driller
installed the well and did the pump test, but a permanent pump has
never been installed as there is no electricity to the well at
this point. Accordingly, the old well permit expired and you will
note that the permit number in the new well permit references that
fact. Please also note that project was previously called "River
Ranch" subdivision.
Let me know if you have any questions with respect to the
enclosed materials. The application fee of $623.00 is enclosed.
Thank you for your assistance.
Very truly yours
KRABACHER AND SANDERS P.C.
B. Jos ph 5a'cher
Ll (-p (00084687.DOC / I)
M
ORDER OF THE STATE ENGINEER
IN THE MATTER OF WELL PERMIT NO. 61697-F
RECEIPT NO. 9501807A
LOCATION: SE'/., NE'/., SECTION 8, TOWNSHIP 9 SOUTH, RANGE 85 WEST, 6'" P.M.
APPLICANT: RIVERWOODS HOLDINGS LLC
THE STATE ENGINEER FINDS:
The well permit was issued on September 17, 2004, and had an expiration date of
September 17, 2006.
On June 28, 2007, the applicant submitted evidence that the well had not been
constructed and/or pump installed prior to the well permit expiration date. The evidence is as
follows: Application for a permit to use an existing well (receipt no. 3618325).
The well permit is hereby expired and is of no further force or effect.
Dated this 1644 day of
�--Y 20 0 7 .
Prepared by: JG
cc: Division 5
Applicant
L173
Li4
Dick Wolfe
For State Engineer
John Gaben
Water Resource Specialist
N 0 0
10/30/99
To; Nancy Mackenzie
Pitkin County
From; Timothy Semrau
S and S Development
RE; Pitkin Iron
Dear Ms. Mackenzie
Is
SEMRAU
SALITERMAN
DEVELOPMENT
Attached is a draft plat reflecting leaving the Walthen ditch in its present
location. The only changes to the plat are splitting of the building envelopes,
relocation of the septic/well envelopes as needed, and removing of the easement
to move the Walthen ditch.
Please review and let me know if the setbacks work for the well and septic
envelopes. The 4 homes are each 4 Bedrooms and restricted to 5800 Sq. ft.
including garages. Per our conversation I used a setback of 82' to the irrigation
ditch, and 132' to the edge of a well envelope. Keep in mind the ditch is only 2'
wide and accurately located on the plat.
If we do encounter groundwater in the spring, I assume the septic fields would
need to be bigger. Do you suggest making the envelopes bigger now?
Please call with suggestions after reviewing the plat.
Timothy Semrau
y? 2086 East Main • Aspen, Colorado 81611 • 970-925-6447 • Fax 970-925-6437
ASPEN/PITKIN ENORONNIENTAL HEALTH DEPARTMENT
ISDS DESIGN CALCULATIONS
Owners Name
House Size (sq. ft.)
Number of Bedrooms in Main House
Parcel ID #
(75 gpd, 100 gpd, or 130 gpd)
Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House
Number of Bedrooms in Detached Caretaker unit
Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit
(If the caretaker unit is ATTACHED, treat as if part of main house.)
Average Daily Waste Flow 800
State Review Required? no
Perc Rate _(T)
Design Flow (Q) = # potential bedrooms X 2 peopleibedroom X gpd X 1.75
Q= 1400
Absorption Area (=Q/5 X SQRT perc rate)
A = 1533.6232 sq. ft. of absorption area required
99 gravelless chamber units without reduction
# of Perc Holes Required: 3
1 in every soil type? Spaced uniformly over proposed area?
A maximum 30% reduction is allowed t'or use of deep gravel or gravelless chambered system,
only if the lot size and soil conditions are optimal.
If a reduction is being proposed, describe why lot size and soil conditions are optimal:
A = 1073.5362 sq.ft. with reduction
69 gravelless chamber units with reduction
Type of system: []Absorption trenches []Absorption bed [] Gravelless chambers
[]Dry well []Seepage Pit []Other (type)
Minimum tank capacity 1750 gallons
SETBACK FROM WELL
# of feet = 132
SETBACK FROM POND, STREAM OR IRRIGATION DITCH
# of feet = 82
SETBACK FROM DRY GULCH
# of feet = 57
Ll
q Printed on Recycled Paper
100
ASPENIPITKIN ENVIRONMENTAL HEALTH DEPARTIENT
ISDS DESIGN CALCULATIONS
Owner's Name Parcel ID #
House Size (sq. ft.) (75 gpd, 100 gpd, or 130 gpd) 100
Number of Bedrooms in Main House
Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House
Number of Bedrooms in Detached Caretaker unit
Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit
(If the caretaker unit is ATTACHED, treat as if part of main house.)
Average Daily Waste Flow 800
State Review Required? no
Perc Rate -(T)
Design Flow (Q) = # potential bedrooms X 2 people/bedroom X gpd X 1.75
Q= 1400
Absorption Area (=Q/5 X SQRT perc rate)
A = 2168.8707 sq. ft. of absorption area required
140 gravelless chamber units without reduction
# of Perc Holes Required: 3
1 in every soil type? Spaced uniformly over proposed area?
A maximum 30% reduction is allowed lot use of deep gravel or gravelless chambered system,
only if the lot size and soil conditions are optimal.
If a reduction is being proposed, describe why lot size and soil conditions are optimal:
A = 1518.2095 sq.ft. with reduction
98 gravelless chamber units with reduction
Type of system: []Absorption trenches []Absorption bed [] Gravelless chambers
[]Dry well []Seepage Pit []Other (type)
Minimum tank capacity 1750 gallons
SETBACK FROM WELL
# of feet = 132
SETBACK FROM POND, STREAM OR IRRIGATION DITCH
# of feet = 82
SETBACK FROM DRY GULCH
# of feet = 57
50 Printed on Recycled Paper
0
MEMORANDUMI
0
To: Tamara Pregl, Community Development Department
From: Nancy MacKenzie, Pitkin County Environmental Health Department
Date: November 17, 2000
Re: Pitkin Iron/River Ranch PUD Minor Plat Amendment
Parcel ID # 2643-081-00-851
I have reviewed the draft plat which relocated the septic and well envelopes for the four
private home lots on the Upper River Road side of the development. The proposed
locations of the wells and septic systems appear to meet the setback distances required
between the wells and septic fields and the septic fields and the existing location of the
Walthen ditch.
Soil data has just been collected for the four ISDS sites and the engineer has verbally
indicated that there appears to be good soils and conventional systems can be installed.
The proposed areas for the septic absorption areas would be large enough for
conventional systems.
However, we have required that the owner and engineer reconfirm the distance to
groundwater during the months of highest ground saturation which for these particular
lots would be during the irrigation season normally in June. If the ground within four feet
below the bottom of the proposed soil absorption system is not dry, an engineer would
have to design a raised system which sometimes requires more area than a conventional
system. The engineer would need to determine if the septic envelopes are large enough to
accommodate a raised system.
Form No. OFFICE OF THATATE ENGINEER •
GVVS-25 COLORADO DIVISION OF WATER RESOURCES
818 Centennial Bldg., 1313 Sherman St., Denver, Colorado 80203
13031966-3581
APPLICANT
EXST
WELL PERMIT NUMBER 61697 -F _
DIV. 5 WD 38 DES. BASIN MD
LoC A Block: Filing: Subdiv: PITKIN IRON/RIVER WOODS PUD
APPROVED WELL LOCATION
PITKIN COUNTY
SE 1/4 NE 1/4 Section 8
S & S DEVELOPMENT, LLC/ RIVER RANCH LLC Township 9 S Range 85 W Sixth P.M.
68 TRAINERS LANDING DISTANCES FROM SECTION LINES
ASPEN, CO 81611- 2000 Ft. from North Section Line
(970) 925-6447
1250 Ft. from East Section Line
UTM COORDINATES
ISSUANCE OF THIS PERMIT DOES NOT CONFER A WATER RIGHT
CONDITIONS OF APPROVAL
1) This well shall be used in such a way as to cause no material injury to existing water rights. The issuance of this permit does not assure the
applicant that no injury will occur to another vested water right or preclude another owner of a vested water right from seeking relief in a civil
court action.
2) The construction of this well shall be in compliance with the Water Well Construction Rules 2 CCR 402-2, unless approval of a variance has
been granted by the State Board of Examiners of Water Well Construction and Pump Installation Contractors in accordance with Rule 18.
3) Approved pursuant to CRS 37-90-137(2) for the use of an existing well, appropriating ground water tributary to the Roaring Fork River, as an
ahemate point of diversion to the Basalt Conduit, on the condition that the well shall be operated only when the Basan Water Conservancy
Distncrs substitute water supply plan, approved by the State Engineer, is in effect and when a water allotment contract between the well owner
and the Basalt Water Conservancy District for the release of replacement water from Ruedi Reservoir is in effect, or under an approved plan for
augmentation. BWCD contract #3.3.5.332.
4) Approved for the installation of a pump in, and the use of, an existing well, constructed on April 23, 2001, to a depth of 73 feet under permit
no. 53782-F (expired).
5) Approved as a well on a residential site of 3.67 acre(s) described as lot A, Pitkin Iron/River Woods Subdivision, Pitkin County.
6) The use of groundwater from this well is limited to ordinary household purposes inside one (1) single family dwelling. The ground water
shall not be used for irrigation or other purposes. All use of this well will be curtailed unless the water allotment contract or a plan for
augmentation is in effect.
7) The maximum pumping rate of this well shall not exceed 15 GPM. The simultaneous maximum pumping rate of all wells operating under
BWCO contract #3.3.5.332 shall not exceed 75 GPM.
8) The annual amount of ground water to be appropriated shall not exceed 0.39 acre-foot. The annual amount of ground water to be
appropriated by all wells operating under BWCD contract #332 shall not exceed 7.7z acre-feel-
9)
cre-feet9) The owner shall mark the well in a conspicuous place with well permit number(s), name of the aquifer, and court case numbers) as
appropriate. The owner shall take necessary means and precautions to preserve these markings.
10) A totalizing flow meter must be installed on this well and maintained in good working order. Permanent records of all diversions must be
maintained by the well owner (recorded at least annually) and submitted to the Division Engineer upon request.
11) This well shall be located not more than 200 feet from the location specified on this permit.
NOTICE: This permit has been approved for the subdivision name as noted above. You are hereby notified that you have the right to appeal
the issuance of this permit, by filing a written request with this office within sixty (60) days of the date of issuance, pursuant to the State
Administrative Procedures Act. (See Section 244-104 through 106, C.R.S.)
NOTE: Canceled permit no. 52410-F and expired permit nos. 53782-F and 57587-F were� ppr�eviously issued for this lot.
NOTE: Parcel Identification Number (PIN): 49-2643-081-03-008 " 4�r.r_ �2'
NOTE: Assessor Tax Schedule Number: R017390
APPROVED
DMW
State
L
Receipt No. 9501807A
J
Form No. OFFICE OF THIRTATE ENGINEER 10
GWS -25 COLORADO DIVISION OF WATER RESOURCES
818 Centennial Bldg., 1313 Sherman St., Denver, Colorado 80203
(303)866-3581
APPLICANT
EXST
WELL PERMIT NUMBER 61697 -F _
DIV. 5 WD 38 DES. BASIN MD
Lot A Block: Filing: Subdiv: PITIKIN tROWRIVER WOODS PUD
S & S DEVELOPMENT, LLC/ RIVER RANCH LLC
68 TRAINERS LANDING
ASPEN, CO 81611-
(970)925-6447
APPROVED WELL LOCATION
PITKIN COUNTY
SE 1/4 NE 1/4 Section 8
Township 9 S Range 85 W Sixth P.M.
DISTANCES FROM SECTION LINES
2000 FL from North Section Line
1250 FL from East Section Line
UTM COORDINATES
ISSUANCE OF THIS PERMIT DOES NOT CONFER A WATER RIGHT
CONDITIONS OF APPROVAL
1) This well shall be used in such a way as to cause no material injury to existing water rights. The issuance of this permit does not assure the
applicant that no injury will occur to another vested water right or preclude another owner of a vested water right from seeking relief in a civil
court action.
2) The construction of this well shall be in compliance with the Water Well Construction Rules 2 CCR 402-2, unless approval of a variance has
been granted by the Slate Board of Examiners of Water Well Construction and Pump Installation Contractors in accordance with Rule 18.
3) Approved pursuant to CRS 37-90.137(2) for the use of an existing well, appropriating ground water tributary to the Roaring Fork River, as an
alternate point of diversion to the Basalt Conduit, on the condition that the well shall be operated only when the Basalt Water Conservancy
Districts substitute water supply plan, approved by the State Engineer, is in effect and when a water allotment contract between the well owner
and the Basalt Water Conservancy District for the release of replacement water from Ruedt Reservoir is in effect, or under an approved plan for
augmentation. BWCD contract 03.3.5.332.
4) Approved for the installation of a pump in, and the use of, an existing well, constructed on April 23, 2001, to a depth of 73 feet under permit
no. 53782-F (expired).
5) Approved as a well on a residential site of 3.67 acre(s) described as lot A, Pitkin IronlRiver Woods Subdivision, Phkin County.
6) The use of ground water from this well is limited to ordinary household purposes inside one (1) single family dwelling. The ground water
shall not be used for irrigation or other purposes. All use of this well will be curtailed unless the water allotment contract or a plan for
augmentation is in effect.
7) The maximum pumping rale of this well shall not exceed 15 GPM. The simultaneous maximum pumping rate of all wells operating under
BWCD contract #3.3.5.332 shall not exceed 75 GPM.
8) The annual amount of ground water to be appropriated shall not exceed 0.39 acre-foot. The annual amount of ground water to be
appropriated by all wells operating under BWCD contract #332 shall not exceed 7.72 acre-feet.
9) The owner shall mark the well in a conspicuous place with well permit number(s), name of the aquifer, and court rase numbers) as
appropriate. The owner shall take necessary means and predutions to preserve these markings.
10) A totalizing Bow meter must be installed on this well and maintained in good working order. Permanent records of all diversions must be
maintained by the well owner (recorded at least annually) and submitted to the Division Engineer upon request.
11) This well shall be located not more than 200 feet from the location specified on this permit.
NOTICE: This permit has been approved for the subdivision name as noted above. You are hereby notified that you have the right to appeal
the issuance of this permit, by filing a written request with this office within sixty (60) days of the date of issuance, pursuant to the State
Administrative Procedures Act. (See Section 24-4-104 through 106, C.R.S.)
NOTE: Canceled permit no. 52410-F and expired permit nos. 53782-F and 57587-F were previously issued for this lot.
NOTE: Parcel Identification Number (PIN): 49.2643-081-03-008
NOTE: Assessor Tax Schedule Number: R017390 O Q�/ 740 Sc
APPROVED �t
DMW V
Receipt No. 9501807A State EngineerDATE
53
DATE
0
i
Form No. OFFICE OF THE STATE ENGINEER
GWS -25 COLORADO DIVISION OF WATER RESOURCES
818 Centennial Bldg., 1313 Sherman St., Denver, Colorado 80203
(303) 866-3581
APPLICANT
RIVERWOODS HOLDING LLC
C/O B JOSEPH KRABACHER
201 N MILL ST STE 201
ASPEN, CO 81611-
(970)925-6300
EXST
WELL PERMIT NUMBER 66160 -F _
DIV. 5 WD 38 DES. BASIN MD
Lor. ,v r900K: rmng: JuedN: Fir KIN IRON/RIVER WOODS PUD
APPROVED WELL LOCATION
PITKIN COUNTY
SE 1/4 NE 1/4 Section 8
Township 9 S Range 85 W Sixth P.M.
DISTANCES FROM SECTION LINES
2000 Ft. from North Section Line
1250 Ft. from East Section Line
UTM COORDINATES (Meters Zone 13 NAD83)
'ERMIT TO USE AN EXISTING WELL rasung: Normmg:
ISSUANCE OF THIS PERMIT DOES NOT CONFER A WATER RIGHT
CONDITIONS OF APPROVAL
1) This well shall be used in such a way as to cause no material injury to existing water rights. The issuance of this permit
does not assure the applicant that no injury will occur to another vested water right or preclude another owner of a vested
water right from seeking relief in a civil court action.
2) The construction of this well shall be in compliance with the Water Well Construction Rules 2 CCR 402-2, unless approval
of a variance has been granted by the State Board of Examiners of Water Well Construction and Pump Installation
Contractors in accordance with Rule 18.
3) Approved pursuant to CRS 37-90-137(2) for the use of an existing well (constructed under permit no. 61697-F, expired),
appropriating ground water tributary to the Roaring Fork River, as an alternate point of diversion to the Basalt Conduit, on
the condition that the well shall be operated only when the Basalt Water Conservancy District's substitute water supply
plan, approved by the State Engineer, is in effect and when a water allotment contract between the well owner and the
Basalt Water Conservancy District for the release of replacement water from Ruedi Reservoir is in effect, or under an
approved plan for augmentation. BWCD contract #3.3.5.332.
4) The use of ground water from this well is limited to ordinary household purposes inside one (1) single family dwelling. All
use of this well will be curtailed unless the water allotment contract or a plan for augmentation is in effect.
5) The maximum pumping rate of this well shall not exceed 15 GPM. The simultaneous maximum pumping rate of all wells
operating under Basalt WCD contract #3.3.5.332 shall not exceed 75 GPM.
6) The annual amount of ground water to be appropriated shall not exceed 0.39 acre-foot. The annual amount of ground
water to be appropriated by all wells operating under BWCD contract #332 shall not exceed 7.72 acre-feet.
7) The owner shall mark the well In a conspicuous place with well permit number(s), name of the aquifer, and court case
number(s) as appropriate. The owner shall take necessary means and precautions to preserve these markings.
8) This well shall be located not more than 200 feet from the location specified on this permit.
9) A totalizing flow meter must be installed on this well and maintained in good working order. Permanent records of all
diversions must be maintained by the well owner (recorded at least annually) and submitted to the Division Engineer upon
requesV__)j 6�,:lo-7
(APPROVED —
JSG
For
Receipt No. 3618325
• •
0111RES0URCE
MENEM
■■■■■ E N G I N E E R I N G I N C
Mr. Tim Semrau, Manager
Pitkin Iron Development, LLC
208 %: E Main Street
Aspen CO 81611
RE: Potable Water Supply for River Ranch Lot A
Dear Tim:
September 17, 2001
This letter summarizes the water quantity and water quality of the potable water supply for Lot
A of the River Ranch Subdivision. The potable water supply will come from a well drilled on
the property under well permit No. 53782-F. The well was drilled in the Roaring Fork Alluvium
to a total depth of approximately 73 feet. The static water level was measured at
approximately 31.5 feet below the top of casing.
The well was tested for water quantity and quality on May 15, 2001. The well was pump
tested by J & M Pump Company for 4.5 hours at a rate of 15 gallons per minute. A total of
4,050 gallons was pumped during the test. The total drawdown measured was 1 inch. The
extremely small amount of drawdown indicates that the aquifer has a high transmissivity and
that the well will produce an adequate physical water supply for a large single family residence
on the lot.
A water sample was obtained at the end of the pumping test by Resource Engineering and
submitted under proper chain of custody to Grand Junction Laboratories. The results of the
laboratory testing indicates that the water ality meets all of the primary drinking water
standards. The hardness was measured a 20 illig rams per liter which slightly exceeds the
recommended secondary standard of 200 ml (grams per liter.
Water softening to remove the hardness and disinfection treatment is recommended for the
water supply. Prior to initial use for a residence, the well should be pumped for 4 to 8 hours
to remove any remaining fine sediment around the well screen area.
Copies of the well pumping test and water quality data are attached.
Please call if you have any questions or need additional information.
Sincerely,
RESOURCE ENGINEERING, INC.
�G
Michael . Erion, P.E.
Water esources Engineer
MJElmmm
876-1.0 U pooble lot a wat.,.875.w d
Attachments
Consulting Engineers and Hydrologists
59`09 Colorado Avenue ■ Glenwood Springs, CO B1 B01 ■ (970) 945-6777 ■ Fax (970) 9411 37
J
JOHN C. KEPHART & CO
GRANO JUNCTION [AURATORIFS
435 NORTH AVENUE PHONE: (670) 242-7616 * FAB: (670) 247-7235 • GRAND ju N�TION; d,;L 6i 111301
•� )1 wTaX11 1
ANALYTICAL REPORT —
Received from:
Resource Engineering
909 Colorado Ave.:�e�^"-
Glenwood Springs, CO 81601
(970)945-6777, FAX 945-1137
Customer No. laboratory No. 6618 Sample water
Date Received
Date Reported 7/17/01
Lab number-
6618
Limits for Drinking
Suggested
Sample ID River Ranch Well
A
by Colo.
Dept. Health
Raw 5/15/01 11:45A
Arsenic(AS)
0.000
mg/l
0.05
mg/1
Barium(Ba)
0.13
mg/l
2.0
mg/l
Cadmi(.tm(Cd)
0.0000
mg/l
0. 005
mg/l
Chromium(Cr)
0.(100
mg/l
0.1
mg/l
Fluoride(F)
0.22
mg/l
4
mg/1
Lead(Pb)
0.000
mg/l
0.015
mg/l
Mercury(Hg)
0.00000
mg/l
0.002
mg/l
Nitrate(N)
0.08
mg/l
111.0
mg/l
Se1enium(Se)
0.004
mg/l
0.05
mg/l
Silver(Ao)
0.0000
mg/l
0.05
mg/1
Color(Co/Pt unit)
0
no official
limit
pH
7.40
no official
limit
Conductivity@25 deg. C
425
umhos/cm
no official
limit
Sodium(Nai
3.8
mg/l
20
mg/1
Cal r_iLAM (CA)
64
mg/l
no official
limit
Maonesium(f1o)
12
mg/l
125
moll
POtaSSi Uim(V)
1.8
mg/l
no official
limit
Chloride(Cl)
4
mo/1
250
mo/1
Sulfate(SO4)
40
mg/l
250
mg/1
Ph•}nol. Alkalinity(CaCO3)
0
mg/l
no official
limit
rota). Alkalinity(CaCD:3+)
168
mg/1
no official
limit
BiCarbonate(HCOI )
203
mg/l
no official
limit
Carbonate(CD3)
0
mg/l
no official
limit
uissolved Solid=_
308
ma/1
500
mg/l
Hardness (CaCD.')
209
ma/1
200
mg/1
rurbidity(NTU)
0.67
1
Boron(B)
0.00
mg/l
no official
limit
Capper (Cu)
0.000
mg/l
1.0
my/1
Ir-on(Fe)
0.00
mg/l
0.3
mg/l
ManoaneselMn)
0.017
ma/l
0.05
mg/l
Mal ybdenum (Mo)
0.000
mg/l
no official
limit
Ammonia(N)
0.00
mg/l
no official
limit
Phosphate (P'
0.01
mg/l
no official
limit
7inc(Zn)
0.008
mg/l
5.0
mg/l
NOTES: (Jf the parameters
tested, only
Hardness
exceeded limit for
ouolic supplies. May cause
mineral
deposits
and lessen
the ef-Fectiveness
0i soap.
L:ab Dir.:
Brian S.
Bauer-
2
WELL DATA
Well Name [% Z07- A
Measuring Point TO�
Total Depth 73
Static Water Level 3/ "
Top of Screen �- Fbynra 3430
Type of Test 2
Pump Intake 72
Observation Wells
!
MOTOR
w.. 10 nL/ /[ISPUMP
wr.
wWl
TT
T�
w r-
.7 —
-7--
4.i G.rr.
MTS l?// AMM
�,p
nui
w
Y•.�rn
rouA.
an
r•n�
ou.mw.
a
�
✓
Ati
m..c.n,
(
7.16ln
1O
' '
S
4: a1, 7s Pr
l7
10: ,50 _ 1'? r.
30-1
I 7"
S
31 '7
I
^ 1 7'
I D
1lo
al�+
20
1 711
"
30
S D
�
x!(101
60
s
�
9�u9
r
oS
.r
f & t-/& �u/l 4
TD�uz�
8811 COUNTY RD. 117
GLENWOOD SPRINGS, CO 81801
(970)948.8189
May 15, 2001
Pitkin Iron Development LLC.
208J East Main St.
Aspen Co 81611
RE:Well Test
Attn: Mr, Semrau,
A four hour #ell test #as performed on Lot A. permit N 053782-F.
The follo#ing results dere obtained:
Well Depth: 73'
Water Level: 3116"
Dra#do#n: 1"
Sustained Yeild: 15 GPM
Clarity: Clear
If you have any questions, please call, 945-6159. Thank You.
J 8 M Pump Co.
A�ww 441
Richard A. Holub
Lic. No. 1196
5S,
DOUBLE ENCASE 1.5 INCH DIAMETER SCH. 40 PVC
PIPE IN 4 INCH DIAMETER SCH. 80 PVC PIPE FOR --
ENCROACHMENTS ON IRRIGATION DITCH (SEE NOTE
FOR DETAILS),
PROPOSED 2,000 GALLON, THREE
CHAMBER VALLEY PRECAST
CONCRETE SEPTIC TANK EQUIPPED
WITH AN ORENCO PF3005 HIGH HEAD
SUBMERSIBLE EFFLUENT PUMP —�
INSTALLED WITHIN AN ORENCO
BIOTUBE PUMP VAULT IN THE THIRD
CHAMBER.
Is
A�
CLEANOUT(typ.)
S.F.R.
BUILDING ENVELOPE
PER BK58/PG2
PROPOSED FOUR
BEDROOM RESIDENCE
RUVER WOODS LOQ' A
NOTE;
1. ENCROACHMENTS MAY BE PERMITTED TO THE 50 FOOT SETBACK FROM EFFLUENT LINES TO AN
IRRIGATION DITCH PROVIDED THAT THE EFFLUENT LINE IS ENCASED FOR A MINIMUM OF 10 FEET ON EACH
SIDE OF THE ENCROACHMENT FOR A TOTAL OF 60 FEET OF ENCASED EFFLUENT PIPE. FOUR INCH DIAMETER
SCHEDULE 80 PVC PIPE SHALL BE PLACED OVER THE EFFLUENT LINE, RIGID SCHEDULE 80 PVC END CAPS
SHALL BE GLUED AND SECURED TO THE END OF THE ENCASEMENT PIPE. A HOLE SHALL BE DRILLED IN THE
END CAP AND BE PLACED AT THE BOTTOM OF THE END CAP SO THAT THE 1.5 INCH EFFLUENT LINE RESTS ON
THE BOTTOM OF THE ENCASEMENT PIPE. THE AREA AROUND THE HOLE IN THE END CAP SHALL BE SEALED
WITH A COMPATIBLE UNDERGROUND SEALANT.
REQUIRED 15 FOOT SETBACK
FROM WALTHEN DITCH LINE.
A�� �% B�N�FO
ROgR�NG F
� ORK RI SER
TOE OF SLOPE
�AT EDGE OF RIVER
ASPHALT
SNOW
STORAGE
AREA
SEPTIC SYSTEM
ENVELOPE
GRAVEL
N
T
EXISTING
WELL
TOP OF BANK /
20' STREAM SETBACK
REC# 441574
MINIMUM HORIZONTAL DISTANCES
FIELD TO:
TANK TO:
PROPERTY LINES
10'
HOUSE
5'
*8 FT. ADDED FOR
TANK
6'
WATER LINES
10'
EACH
100 GAL. /
HOUSE
20'
SURFACE WATER
50'
WATER LINES
25'
DRY DITCHES
10'
DAY
DESIGN FLOW
SURFACE WATER
50' *
WELLS
50'
OVER
1,000
DRY DITCHES
25' *
PROPERTY LINES
10'
GAL.
/ DAY.
WELLS
100'
IRRIGATION DITCH
50' *
BUILDING SEWER TO:
EXISTING FIELDS
20'
WATER LINES
10'
CUT BANKS
4X VERT. CUT HEIGHT
WELLS
50'
PROPOSED 960 SQUARE FOOT
MOUNDED ABSORPTION AREA WITH
DIMENSIONS 20 FEET WIDE BY 48
FEET IN LENGTH. SEE FIGURES 3
AND 4 FOR DETAILS.
APPROXIMATE SCALE;
1 INCH = 20 FEET
LOT A, RIVER WOODS AT WOODY CREEK
OWTS SITEPLAN
Ge Ptech
HEPWORTH-PAWLAK GEOTECHNICAL
4070299
FIGURE 1
5q