Loading...
HomeMy WebLinkAboutpitkin.eh.264315200012 (1999)0 ui 0 I rn rn r J 3 0 SE RTy TlE 3611, N 1 s, r� Eqs r �P� TgS, Rg514 W 6pM T O,o C SURVEY INFORMATION PROVIDED BY LOUIS H. BUETTNER SURVEYING 0040 WEST SOPRIS CREEK ROAD BASALT, COLORADO 81621 !I� 970-927-3611 77 SEE REALIGNMENT DRAWING FOR CORRECT BNDY 20 0 20 40 1 inch = 20 feet EXISTING GROUND J I BACKFILL - 3'MINUS 6' - TOP SOIL INSTALL 1-1/2' PERFORATED \ SCH 40 PVC LINE INSIDE INFILTRATOR, HANG FROM TOP OF INFILTRATOR 1/4' HOLES @ 60' OC 30 -DEGREE OFF BOTTOM ON EACH SIDE OF PVC TYP 6 TRENCHES FULL LENGTH OF INFILTRATORS BEDDING ZONE - FINE NAIIVE MATERIAL NO LARGER THAN 1' IN DIAMETER WITHIN 6 ' OF INFILTRATOR vvvvvv vvvvvvvvvv vvv vvv v vvv vvv vv' vv / vv INFILTRATOR ra tip DRIv EW AY 8- 90 - FOOT INFILTRATOR TRENCHES - 15 UNITS IN EACH TRENCH TRENCHES. IE TO BE - 94.5 FIELD VERIFY MINIMUM DEPTH IS 2.5 -FOOT TO BOTTOM OF TRENCH, 10' APART MINIMUM c/N d�I\ \F �9r QOM' REUSE EXIS' 750 GALLON PLUG PIPING TO EXISTING SYSTEM AND ABANDON N WELL gnu. INSTALL 2EW 1,000 GALL❑ SEPTIC TANKS. ELD VERIFY 4' EX NECT TO EXISTING T NOT DISTR AVE SI E 3' SCH 80 TRANSMISSION LI ANIFOLD AT POSITIVE SLOPE UP TO NEW 750 GALLON S =D TANK AS DOSING SEE AT' AED DESIGN ES AND DETAILS FOR R NFO, IE TO BE FILED NOTES PROFILE HOLE 1, SEE ATTACHED DESIGN NOTES AND MEMORANDUM FOR MORE INFORMATION ON THE SYSTEM. 2. 1-112' PIPING TO BE HUNG INSIDE THE INFILTRATOR UNITS IS TO BE PERFORATED WITH 1/4' HOLES AT 60' ❑C d'•'e 3. FIELD VERIFY ALL ELEVATIONS Sinn PERCOLATION HOLES 4. BOTTOM OF TRENCHES TO BE 94,50 TRENCH DETAIL N T S 5, GROUND WATER AT 90.00 6, PUMP\DOSING TANK INFORMATION IN MEMORANDUM AND ON DETAIL SHEET 7. ASSUMED FF HOUSE TO BE 99,00 8. IE OF PIPING AT TANK ASSUMED TO BE 93,00 9. BOTOM OF DOSING TANK IS 89.00+\- 10, TRENCHES TO BE FIELD ADJUSTED TO MEET REQUIRED SETBACKS 11, FIELD MODIFICATIONS MAY CHANGE ALIGNMENT AND # OF TRENCHES 12. WELL SETBACK 1881, STREAM SETBACK 138' RIFIED 18E' WELL OFFSET INSTALL 17 TRENCHES OF INFILTRATORS 7 UNITS PER TRENCH IN 14, (42'), AND 9 UNITS— UNITS PER TRENCH IN 3, ( 48'), 122 UNITS TOTAL' %\ BED SYSTEM, BOTTOM OF TRENCH 9 R @ 90,00 MAY REQUIRE MINOR FILL ON TOP FOR 18' COVER a/I WIRE FENCE \TBM - (MWE) ~100,00 PIN AT CORNER ^O� �0 INSTALL 1-112' SCH40 PVC PERFORATED j� PIPE IN EACH ROW OF INFILTRATORS l 2 - 1/4' HOLES AT 60' oc & EACH ❑FF BLIT. (v HANG LINE FROM TOP OF EACH I ILTRATOR�� Aw� PROJECT NUMBER 99-025.01 DESIGN: GDD DETAIL: GOD CHECK: VENT AT END OF EVERY THIRD TRENCH REVISED DRAWIN :8/3/99 DD OWSLEY RESIDENCE SEPTIC SYSTEM PLAN AND DETAILS DESIGN INFORMATION ughlin Alcott `. DATE: 6/99 DRAWINItl NUMBER G S —