Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
pitkin.eh.264315301003 (2003)(Garage & Rec Center)
Document Layout (From Most Recent to Oldest Permit) Permit Application Log Sheet/Notes & Photos Communications As -built Design Engineer Design Soil Information Water Permit & Information Second System on property Third System etc. Floor Plans Please See Building and Land Use Approvals Files for additional information Pitkin County Environmental Health Department Permit for an Individual Sewage Disposal System 0405 Castle Ck Rd, Aspen, Colorado 81611 Phone 970-920-5070 / FAX 970-920-5077 Permit# 02084 Parcel ID# 2643-153-01-003 Type of permit New( ) Repair( ) Addition to House( X ) Recreation Room in Garage Name of Owner Patrick Lally Street Address 909 White Star Drive Property legal description Size of lot 14 Water source 909 White Star Drive, Lot 8 acres Total square footage of the house 995 # of bedrooms in house 0 # of offices, lofts & similar sized rooms in house Caretaker unit N/A Total square footage of the caretaker unit # of bedrooms in caretaker unit # of offices, lofts & similar sized rooms in caretaker unit Designed for what # rooms (list) Toilet and sink for Recreation Room only —**but sized based on 2 bedrooms Permit information Designed by Church & Associates, Inc Mailing Address 4501 wadsworth Boulevard, Wheat Ridge CO 80033 Perc rate 20 mpi Profile hole depth 8 ft Septic tank capacity 1,000 gallons" Depth to groundwater or bedrock +8 It Absorption area 470/235 w/ 50% reduction— Comments Septic permit approved per compliance with the engineer design and specifications dated October 15 , 2002. Any changes must be approved by this department and the design engineer prior to them being made. Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin County ISDS regulations. Design is for a 1,000 concrete, two-compartment septic tank with an effluent filter on the outlet. Engineer has taken a 50% reduction in size in the absorption area for using graveless chambers in a trench configuration. There will be two trenches, each one chamber wide by 8 chambers long for a total of 16 chambers This department does not endorse any brand of products. The engineer must do a final inspection of the installation and submit an as -built letter to this department. This department must also be called for an inspection with a minimum of 48 hours advanced notice. Permit approved by: 6 Date: I b Plans and specifications of the pr osed individual sewage disposal system have been reviewed and are considered satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was issued unless system construction has commenced or an extension has been approved in writing by the Department. As -built drawings must be included with this permit before the final approval will be issued. staller: F4 Approval: Date: / PITKIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM 0405 Castle Creek Road, Suite 10, Aspen Colorado 81611 Phone 970-920-5070/Fax 970-920-5077 Name of OWNER P A7 R 1 Owner's Mailing Address V ', LA KEv w N S p City, State, Zip Business Phone: Home Phone: - 4 E-mail Address: Primary Contact Person (all communication regarding this permit will go through this person) Name UPE 7 Erc C 1h41 6 Company k w \ Contact Mailing Address o - 3 City, State, Zi , ) (.o `1 \ Business Phone A Ll2'LA- 2i Cell Phone : Fax: ` `1-") S E-mail Address: Parcel ID # (available from assessor's office at 9205160 or at www.aspen.com/assessors Street address of property `l0 i W la i -T F `lrA U0. \,j E Legal Description: Lot ,Block Filing Subdivision Size of lot: � L) acres. Type of proposed structure: �Z E c R r� Total square feet of house 0C S 41 # of bedrooms (potential) in house Caretaker Unit: Attached ( ) Detached ( ) N I A Total area(so. R.) of caretaker unit # of bedrooms (potential) in Permit is for. New Home ( ) Repair due to failure ( ) Remodel/Addition N )Emergency use ( ) Water: Private well ( ) Spring ( ) Stream ( ) Community/Public Water System (y), If community system: Name of system The fee for a ISDS application is $330 for a permit that takes 6 hours or less for the department to approve. If approval takes longer than 6 hours, a rate of $65 per hour will be charged. The maximum fee is $1000. The basic fee of $330 is due at the time of application. The remainder, if any, will be due in two stages: first, at the time of issuance of the ISDS permit; second, before final approval of the ISDS permit. Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information is true and accurate and that I have provided true and accurate information on locations of all existing and proposed wells, contour intervals, buildings, property lines, ditches, slopes, waterlines, springs, suction or irrigation lines, drinking water cisterns, drain tiles, irrigation ditches, lakes, water courses, streams, fioodplains, dry gulches, and existing septic systems. I hereby certify that any such features not shown on attached site map are not present. Issuance of the permit does not imply the approval of any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all approvals and permits have been obtained. The Aspen/Pitkin Environmental Health Department, Pitkin County and employees of these agencies will be held harmless should the individual sewage disposal system fail or malfunction. The permit to construct is issued on information submitted by the applicant or his/her representatives. The owner assumes esponsibility in case of failure of the system. Signature of applicant Date 10 a4 O Received by IO') -o-1 Receipt # LI Date GtisdsUsdsapp\isdsa . oc .\�"/t_� D$v\ & vti `i i CHURCH & Associates, Inc. ENGINEERS & GEOLOGISTS December 2, 2002 Jack Wilkie Builders, Inc do Deanna Raso 20 Sunset Drive, Suite 3 Basalt, Colorado 81621 Subject: Installation Observation 909 White Star Drive Pitkin County, Colorado Job No. 15333W Ms. Raso, As requested, we observed the installation of the onsite wastewater system for the subject site on November 19, 2002. The system was designed under our Job No. 15333W, dated October 15, 2002. The system includes the installation of a 1000 -gallon, two-compartment, precast concrete septic tank with an effluent filter on the outlet, and two chamber -trenches with a concrete distribution box. Each trench had 1 row of 8 chambers, for a total of 16 chambers and 248 square feet of infiltrative area. An as -built drawing is included as Figure 1. Jessie, with Aspen Earth Moving, was instructed to `bed' the four -inch PVC sewer pipe from the house to the tank to achieve proper support of the pipe, prior to backfill. The components of the OWS were installed in conformance with our plans and specifications. Sincerely, CHURCH & Associates, Inc. ,�. rlt Timothy R. Petz Project Manager TRP/erb 2 copies sent Copy to PCEHD, Attn: Nancy MacKenzie DENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 80033 303.463.9317 Fax: 303.453.9321 Reviewed by 11; re f.T eEll RECEIVED DEC 0 5 2002 PITKIN COUNTY ENVIRO;Vp11ZNTAL HEALTH 909 WHITE STAR DRIVE, McLAIN FLATS PITKIN COUNTY, COLORADO OB NO. 1 16- rj ON PROPERTY LINE 248 SF OF INFIL A IN GRAVELESS CHAMBER -TRENCH EACH TRENCd-�E ROW \ CHAMBERS DIRT C i 100 -GALLON, TWO -CO TMENT, PRECAST CONCRETE -SEPTIC EPTIC TANK WI N EFFLUENT RIBUTION BOXY ER ON THE UTLET. \ AS -BUILT L_ 61 SCALE 1°=40' 12/02 FI RE 10 !E I itLv r -%X ✓V H R6 3T6ita ate,,,{ Q-15-02 L—P lk III -es ES Li MSCI ----------------- 0 CHURCH & Associates. Inc. ENGINEERS & GEOLOGISTS October 15, 2002 Jack VlWilldeBuilders, Inc do Deanna Raso 20 Sunset Drive, Suite 3 Basalt, Colorado 81621 Subject: Subsurface Investigation and OWS Design, Proposed 2 -Bedroom Unit 909 White Star Drive, Pitkin County, Colorado Job No. 15333W Ms_ Raso, As requested, we investigated subsurface conditions and designed an onsite wastewater system (OWS) for the proposed 2 -bedroom unit. The investigation was performed on October 1, 2002. SITE CONDITIONS The property is in a residential area of Pitkin County, where OWS are required. There is an existing resi- dence served by an OWS presently. A 2 -bedroom unit is proposed north of the existing residence, which will utilize a separate OWS. The proposed drain field area for the 2 -bedroom unit has a 20% slope to the south and has a moderate cover of native grasses. The proposed structure will be served water by the local water district. PROPOSED CONSTRUCTION �Ec t�pc,r✓` A9w beikeem uai� with a living area of 995 square feet (SF), is proposed at the location presented on Figure 2. The OWS was sized based on 2 bedroom, which requires a 300 gallons per day (GPD) average loading using Pitkin County Environmental Health Department (PCEEiD) loading of 75 gallons per day per person. The sewage loading with a peaking factor of 1.75 is 525 GPD. SUBSURFACE A subsurface investigation was performed by drilling four percolation holes, 13 to 27 inches deep, and one profile hole at the locations indicated on Figure 2. Subsurface materials in the profile hole consisted of 1.0 feet of topsoil, underlain by clayey sand to 3.0 feet, underlain by slightly sandy clay to 7 feet, underlain by clayey sand to the maximum depth explored of 8 feet. No ground water was encountered. Percolation tests indicate percolation rates of 16 to 27 minutes per inch (MPI). The average percolation rate is 20 MPI. Percolation data is presented in Table 1. RECOMMENDATIONS The installation requires a septic tank and two chamber -trench drain fields at the location presented on Figure 2. The OWS design is based on an average sewage load of 300 GPD and a percolation rate of 20 MPI. The installation includes a 1000 -gallon, two-compartrnent, precast concrete septic tank with an DENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 90033 303.463.9317 Fax: 303.463.9321 . Sub# Investigadon andOWS Design Job No. 15333W, 10-15-02 Z ($ I to C" Page 2 effluent filter at the outlet and two chamber -trenches. The trenches must have 1 row of 8 chambers for a total infiltrative area of 248 SF. A flow splitter basin or distribution box is required to distribute effluent. If gravity flow cannot be achieved from the septic tank to the drain field our office should be contacted for pump specifications. Vehicle movement over the drain field area during construction should be kept at a minimum to minimize compaction of the receiving soils. The bottom of the bed should be scarified with a pick, shovel, or backhoe bucket teeth prior to the addition of the chambers. The surface of the field should be seeded after installation of the fields. A native seed mix should be sown at the drain field to revegetate the surface. These mixes do not require irrigation and develop a growth 10 to 15 inches high. No automatic sprinkler system should be installed over the fields. OPERATION AND MAINTENANCE The owner must realize an OWS is different from public sewer service. The owner must be aware of and assume responsibility for maintenance of the system. In the absence of a monitoring program, the septic tank should be pumped every two years. Effluent filter and screened vaults, as applicable, are to be cleaned during pumping. There are daily considerations such as not putting plastic or other nonbio- degradable materials into the septic system. Garbage disposal use should be minimized. The backwash of a water softener may be harmful to the OWS. A separate drywell should be constructed for the backwash waste, if a softener is installed. Chemically treated water from a swimming pool or spas should not be introduced to the OWS. LIMITATIONS An OWS design must be installed by a contractor who is experienced in its installation. Our investigation, layout, design and recommendations are based on data submitted. If subsurface conditions different from those described in this report are encountered, we should be notified to evaluate the change on the proposed OWS. If the health department modifies this design, we should be contacted to evaluate the impact on the performance of the OWS. The county and our firm must be contacted upon completion of the OWS All construction is to be in accordance with the ISDS regulations. Pipe type and size, burial requirements, septic tank construction, and other specifications, which are not depicted in our report, are to conform to the requirements of the ISDS regulations. The installer of the system is to have demonstrated knowledge of the PCEHD ISDS regulations and requirements. If there are questions, please call. The project engineer for this site is Tim Petz. CHURCH & Associates Inc. 11,L2.P�- Timothy R Petz, Project Manager 3 copies sent, via FID EX 1W Reviewed Edward O. Church, P. 0. 0 909 WHITE STAR DRIVE, McLAIN FLATS PITKIN COUNTY, COLORADO JOB NO. 15333W CI 0 FENCE ON PROPERTY LINE 130 \120 DIR DRIV AY RTIN ESICE \ \ \\ \ 110 80 \\ 90 \ 100 \\ ` 70 ` **�� Wy�T� ST **.. N \ 4?/p 0000� 100 SITE PLAN / / SCALE 1"=100' 10/15/02 FIGURE 1 909 WHITE STAR DRIVE,IN FLATS 1"=40' PITKIN COUNTY, COLORA O ON PROPERTY LINE 8 S.F OF INFILTRA EA IN Z GRAELESS CHAMBER -TRENCH EACH TRENCH H R0W OF 8 CHAMBERS ®• 0 ON/ 3» \ VENT PIPES t PLAN, OCATION OF .TION HOLSk, AND LOCATION OF PROPOS S N L PVC 100 ALLON ONCR SE FIL ON REMODEL 10/15 FI ARE TYPICAL PLAN VIEW - N.T.S. GRAVELLESS CHAMBER 3.00' BY 6.25' 4" SDR 35 P OBSERVATION/VENT PIPE TYPICAL CROSS-SECTION - N.T.S. 4" SDR 35 PVC OBSERVATION/VENT PIPE WITH CAP 3.0' EXTENT OF EXCAVA CALCULATIONS AND SPECIFICATIONS DESIGN CRITERIA 2-8EDROOM UNIT, <2000 SF LOADING — 75 GAL/DAY/PERSON TOTAL AVERAGE LOADING — q = 300 GPD PERCOLATION RATE — t = 20 MPI AREA = (1.75 X q X sqrt t)/5 AREA =470 SF REDUCTION FOR USE OF CHAMBER—TRENCHES — 50% TOTAL AREA = 235 SF TOTAL - TWO TRENCHES C FOR ORAU/AG f CHAMBER `� BY 6.25' TRENCH SPECIFICATIONS NUMBER OF TRENCHES = 2 LENGTH OF EACH TRENCH = 50 FEET, 8 CHAMBERS WIDTH OF EACH TRENCH = 3 FEET, 1 CHAMBER TOTAL NUMBER OF CHAMBERS = 16 CHAMBERS TOTAL AREA = 248 SF TO BELE TO REM e1 TOP VIEW SPUTTER BASIN ISTRIBUTION BOX FLAW SPLITTER BASH' FOR GRAVITY FLOW EFFLUENT R STAMLESS STEEL !E GASKET. N GE PIPE JISCH E, OI TREATMENT UNIT SPECIFICATIONS TOTAL MINIMUM CAPACITY — 1.75 X q X (30 HOURS/24 HOURS) = 657 GALLONS RECOMMENDATION — ONE 1000—GALLON, TWO—COMPARTMENT, PRECAST CONCRETE SEPTIC TANK WITH AN EFFLUENT FILTER ON THE OUTLET DRAIN FIELD DETAILS 10/15/02 E03 JOB NO. 15333W Septic Tank with 4" Dia. Biotub? Effluent Filter 0 0 1000 -Gallon, Two -Compartment, Precast Concrete Septic Tank with Effluent Filter o systems®Irimrporawd Vault Inlet Ports 0 High Laval Alarm Flaot (optional) Filter Cartridge FT0400 Series Biotube Effluent Filter Patents # 4,439,323 h 5,492,635 DISCLOSURE THE PRESIDENT OF CHURCH do ASSOCIATES, INC. IS A Foreign Patents Pending SHAREHOLDER OF SCG ENTERPRISES, INC. WHICH IS A LOCAL DISTRIBUTOR OF ©1997, Orenco Systems, Inc. ORENCO SYSTEMS, INC. PRODUCTS. 10/15/02 JOB NO. 15333W FIGURE 4 PVC Splice Box w/Cord Grips 614 AIRWAY AVENUE SUTHERUN, OREGON Fiberglass Gasketed Lid with 97479-9012 Stainless Steel Bolts Inspection Access Riser and Lid at Slope Ground PVC Riser with Grommets) TUHHONC or near ground Away From Ruler (bond to tank adapter with (541) 459-4449 surface), optional — — recommended adhesive) FAO9MAe Tank Adapter f ?I' Conduit to —I— - Filter Cartridge Handle (541) 459-2B64 (asst or halted) E Alarm Panel (field cut to desired height) Conduit Seal Tank Adapter (cost or bolted) Inlet Tee Vent Orifice Effluent Discharge Liquid Leval $qirModulating TM 2' Discharge Orifices Vault Inlet Ports 0 High Laval Alarm Flaot (optional) Filter Cartridge FT0400 Series Biotube Effluent Filter Patents # 4,439,323 h 5,492,635 DISCLOSURE THE PRESIDENT OF CHURCH do ASSOCIATES, INC. IS A Foreign Patents Pending SHAREHOLDER OF SCG ENTERPRISES, INC. WHICH IS A LOCAL DISTRIBUTOR OF ©1997, Orenco Systems, Inc. ORENCO SYSTEMS, INC. PRODUCTS. 10/15/02 JOB NO. 15333W FIGURE 4 PRO - 1: 0 0 TABLE 1 - PERCOLATION TEST RESULTS 909 White Star Drive DATE OF TEST: 10/01/02 Pitkin County, Colorado feet descrintion 0 - 1 Topsoil, root zone 1 -3 Sand, clayey. slightly ravelly, dense, moist. red/brown 3 - 7 Clay, slightly sandy very hard, moist, brown 7 - 8 Sand. clayey. ravel/ , with large cobbles, dense, moist, red/brown NO GROUNDWATER WAS ENCOUNTERED WITHIN EXCAVATION NUMBER OF HOLES: 4 AVG PERCOLATION RATE (MPI): 20 JOB NO. 15333W AVG. INTERVAL DEPTH TIME DEPTH DEPTH HOLE HOLE OF HOLE, INTERVAL, START, END, CHANGE, FERC. NUMBER (INCHES) (MINUTES) (INCHES) (INCHES) RATEPERC (INCHES) RATE RATE, (MPI) tMPll NUMBER OF HOLES: 4 AVG PERCOLATION RATE (MPI): 20 JOB NO. 15333W PRO - 1: 0 r� TABLE 1 (CONT) - PERCOLATION TEST RESULTS 909 White Star Drive Pitkin County, Colorado feet description DATE OF TEST: 10/01/02 0 - 1 Topsoil, root zone 1 -3 Sand, clayey, slightly ravel) . dense, moist. red/brown 3 - 7 Clay, slightly sandy, very hard, moist, brown 7 - 8 Sand, clayey,gravelly, with large cobbles, dense, moist. red/brown NO GROUNDWATER WAS ENCOUNTERED WITHIN EXCAVATION INTERVAL AVG. DEPTH TIME DEPTH DEPTH HOLE HOLE CHANGE, PERC. OF HOLE, INTERVAL, START, END, PERC. NUMBER (INCHES) (MINUTES) (INCHES) (INCHES) (INCHES) RATE RATE, (MPI) 20 MPI 4 15 20 5.25 9.00 3.75 5 20 5.13 7.38 2.25 9 20 4.13 6.38 2.25 9 20 4.75 6.13 1.38 15 10 4.63 5.25 0.63 16 16 10 5.25 6.00 0.75 13 NUMBER OF HOLES: ' 4 AVG PERCOLATION RATE (MPI): 20 JOB NO. 15333W IIF, 0 _, 90 130 / / Y / / / , / � / / , / . ' ,' �' / / � / / ' � / / /' � / / ' � /%L14}67.8 To '� E:•IMILIIrtk�D Twy st 1111 12 F14 F � WA -Tr / �' /✓ 6 I DATUM- 4�O 00041 1 � W � SC2vfG•E / 101-0 i 1 / 5 TpFt4pRT* 11 F / / I r°lI,,IO 1 I Two TSV. wt DRIV19 1 � ( I 1 vx1�-T'W Far#c / I MJ�M1�T� �YI�T6 COOT Iucsif ' i .r,•• _ - _ \\ {\ \ / / / 1 J EL I ♦'/!O C WTRAcToR TO CAST'& 3ly ALL ELEVATIOI"S A$ovV /BELOW ORADE ARP 2,ASED C IW E5rABLa5N D SITS ISO •LCR MARK FOR ACTUAL ELP-vATIO4 AbOYV 5E0. LEVEL "PF -KR TO LOGA,L �ITYICOUNTY DATUM: