Loading...
HomeMy WebLinkAboutpitkin.eh.264309300009 (2000)(Main House)Document Layout (From Most Recent to Oldest Permit) Permit Application Log Sheet/Notes & Photos Communications As -built Design Engineer Design Soil Information Water Permit & Information Second System on property Third System etc. Floor Plans Please See Building and Land Use Approvals Files for additional information. 0 a Aspen/Pitkin Environmental Health Department Permit for an Individual Sewage Disposal System 130 S. Galena St. Aspen, Colorado 81611 Phone 970-920-5070 / FAX 970-920-5074 Permit # ,z p p/ (o Parcel ID # 2643-093-00-009 Type of permit New( X) Repair( ) Addition to House( ) Name of Owner Janet Schoeberlein Street Address 7274 UDDer River Rd. Woodv Ck Property legal description Size of lot 1.8 acres Total square footage of the house 5,300 Water source Private well # of bedrooms in house 3 # of offices, lofts & similar sized rooms in house 1 Caretaker unit Total square footage of the caretaker unit # of bedrooms in caretaker unit # of offices, lofts & similar sized rooms in caretaker unit Designed for what If rooms (list) (4) FOUR = 3 bedrooms and 1 office Permit information Designed by Church & Associates, Inc Mailing Address 4501 Wadsworth Boulevard, Wheat Ridge, CO 80033 Perc rate 7 Profile hole depth 8 ft Depth to groundwater or bedrock 8 ft **to be reconfirmed Septic tank capacity 1750 minimum Absorption area 741 sq ft, 30 % redu.for infiltrator = 519 sq It Septic permit approved per compliance with the engineer design and specifications dated April 24, 2000 and Clarification Letter dated May 4, 2000. Any changes must be approved by this department and the design engineer prior to them being made. This department and the engineer design require that no work can be done under this permit until ground water level is confirmed during the months of highest runoff and ground saturation. Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin County ISDS regulations. The engineer has stated that the setbacks from the irrigation ditches and well can be reduced and contamination by the ISDS will be prevented. The design is for one 2000 gallon two-compartment concrete tank with a pump in a biotube vault. There are 3 trenches with'14 gravelles chambers in each trench for a total of 93 chambers. This department does not endorse any brand of products. The engineer must do a final inspection of the installation and submit an as -built letter to this department. This department must also be called for an inspection with a minimum of 48 hours advanced notice. Permit approved by: /SLY Date: Plans and specifications of the oposed individual sewage disposal system have been reviewed and are considered satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was issued unless system construction has commenced or an extension has been approved in writing by the Department. As -built dra ngm s ust be included with this ( �aInstaller: �n r Inspection before the final approval will be issued. Date:` D A frL&D 0 Hak4.P 1 Dud 34l c�tv dosiry5 �iam.de�-� v „ T" Ne -W 7o i� srui/ ri SeYS Tv ASP/PITKIN ENVIRONMENTAL HEALTH DEPARTMENT APP ION FOR INDIVIDUAL SEWAGE DISPO* SYSTEM 130 S. Galena St.. Aspen Colorado 81611 Phone 970-920-5070/Fax 970-920-5039 Permit 8 Parcel ID # Permit For. New Ihis station ( Repair Name of OWNER IZy70 Street Address ? r ✓fir ' r r— Owner's Marling Address �.S n_0 / D D a Business Phone: 30 -,Soo -O Home Phone 0 Y oZ a Rxel Legal Description: Lot ,Block _ / Size of lot /'e. � acres Type of proposed structure: Total areaaiwng space (sq. 8): J . -5 O V #1A Bedrooms, offices -and similar size rooms. Primary Contac Person ^` /�� l7 V,611 1/ ' '— Contact Mailing Address � � oC] �( �,� ��/�l /i / rL(.0 7 ✓Q,/r well ( )Spnng ( )Stream ( ) Community/Pubbe (Name of System) Is Proof of Adequate Water Attached (Required l ? (AjPes ( ) No (A water quality test and wall pump test or approval letter from community system) Has this project been approved by Pitkin County 7 (y4es ( ) No Is a Copy of the floor plan attached ( Required ) ? W i es ( ) No Is a Coov of the site Dian attached Application for an individual sewage disposal system is hereby submitted. I hereby candy that the above Information is true and accurate and that I have provided Irue and accurate information oD locations of all existing and proposed wells, contour intervals, buildings, property lines, ditches, slopes, waterlines, springs. suction or irrigation lines, drinking water cisterns, drain tiles, irrigation ditches. lakes, water courses, streams. noodplains, dry gulches. and existing septic systems. I acknowledge that any false or incomplete information will invalidate the application and any subsequent permit. Issuance of the permit does not imply the approval of any other permit required for construction pursuant to Pitkin County codes. No cons el'on may be undertaken until all approvals and permits have been obtained. The owner assumes all responsibilities in rase of failure or inatlequacy of this system. _ Signature of applicant Date ZG'axt) ----------------- For department use below PERMIT FOR INDPADUAL SEWAGE DISPOSAL SYSTEM Desion Criteria of system to be Installed (Any changes must be submitted and approved in writingt Perc Rate min per inch Profile Hole Depth feet Septic tank capacity: gallons Absorption areai sq. ft. An Inspection is required prior to backfill of any component of the distribution system. Design by Engineer Required ? ( ) Yes ( ) No All plans and specifications of the engineer must be followed. Any changes must be approved by the AspeNPitkin Envirommital Health Department in writing and the engineer must certify the final installation to the Environmental Health Department in wnling. Permit approval by: Date Plans and speufirabons of the proposed individual sewage disposal system have been reviewed and are considered satisfactory. Penrlissort is hereby granted to the owner or the agent to perform the work indicated In accordance with the Pekin County ISDS Regulation in effect M the time of issue. This permit becomes invalid 6 months from the date that the permit was issued unless system construction has commenced or an extension has been approved in wining by the Department. As -Built drawings must be included with this permit before the final approval will be issued. Installer: Receipt # Date received Received by Site Plan Well Permit and Floor Plan Water Quality Test or Comm Dev Approval Water System Letter Final Inspection Approval: Date: p 5-d2 6 4 ;Loma _ Soils Test _ Date Info Complete Final Insp Requested •PEHD 1. Feb 07 01 10:23a Accnrrintac February 7, 2001 Jan Schoeberlein 26054 Centennial Trail Golden, CO 80401 ENGINEERS & GEOLOGISTS P. '2&L/3-0�'3-0v --007 Subject: [.'valuation of Existing OWS, Proposed Schoeberlein Caretaker Unit 7274 Upper River Road Pilkin County, Colorado Job No. 12220 Ms. Schoeberlein, As requested, we have evaluated the possible installation of a washer and dryer, to be placed in a proposed caretaker unit on the subject property. We understand the caretaker unit will be using the existing onsite wastewater system (OWS) installed in the early 1980's. The existing OWS is 1 197 square feet (SF), and is a 'standard' drain field with 4" PVC pipe and gravel. The existing OWS was excavated in April, 2000 in two locations and appeared to be functioning properly. The loading of a laundry washer is 19.5 gallons/per/day per person. A two-bedroom residence would bring the loading to 78 gals/day, The existing OWS (tanks and drain field) can handle the additional loading from a laundry washer place in the caretaker unit. We are only evaluating the addition of a laundry washer. Sincerely, ClIURCH and Associates, Inc Tim R. Petz, Project Manager TRP 2 copies sent copy to APEHD, Attn: Carla Block DENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 80033 303.463.9317 Fax: 303.463.9321 CASTLE. ROCK 303.6604358 EVERGREEN 303.8161,155 LOVELAND 970.6632124 Tom Dunlop, 11:40 AM 03/30/2000 -0700, Janet Schoberlein Page 1 of 1 r i X -Sender: tomd@comdev.ci.aspen.co.us X -Mailer: QUALCOMM Windows Eudora Pro Version 4.2.0.58 Date: Thu, 30 Mar 2000 11:40:41-0700 To: Nancy MacKenzie < nancym@ci.aspen.co.us >, Carla Block <carlabt@ci.aspen.co.us> From: Tom Dunlop <tomd@ci.aspen.co.us> Subject: Janet Schoberlein Hi, I just spoke to Janet Schoberlein 923-2801 who lives in the Woody Creek area. She wants to replace her current 4 bedroom home with a new one. Her isds was installed around 1980, she is not sure exactly. I told her we might have a permit, but could not guarantee it. She wanted to do a perc test before April 15th, but I told her we wanted to wait until after that date because of cold nights and days that might effect the test results. She is not sure if she needs a new system or not. Her old one has been working fine according to her. She has pumped the tank regularly. Janet will be calling one of you (probably Nancy) to search for her old permit. FYI, TSD Thomas S. Dunlop, Director Aspen/Pitkin Environmental Health Dept. 130 S. Galena St. Aspen, CO 81611 tomd@ci.aspen.co.us 970 920-5073 desk 970 920-5074 fax Printed for Nancy MacKenzie.<nancym@ci.aspen.co.us> 03/30/2000 CHURCH & Associates, Inc. ENGINEERS & GEOLOGISTS August 17, 2000 Jan Schoeberlein 26054 Centennial Trail Golden, CO 80401 Subject: Installation Observation, Proposed Schoeberlein Residence 7274 Upper River Road Pitkin County, Colorado Job No. 12220 Ms. Schoeberlein, As requested, we observed the installation of the onsite wastewater system (OWS) for the subject site on August 1, 2000. The system was designed under our Job No. 12220, dated April 24, 2000. The system includes the installation of a 2000 -gallon, two-compartment, precast concrete septic tank with an effluent filter on the outlet, followed by a 1000 -gallon single -compartment precast concrete septic tank with a pump. Three chamber -trenches were installed, as indicated on Figure 1. Each trench had one row of 12 chambers, for a total infiltrative area of 558 square feet (SF). An as -built drawing is included as Figure 1. The pump and effluent filter were in place and wired at the time of our visit. The installation foreman, Jinx Stone, may activate pumping system at his discretion. The components of the OWS were installed in con- formance with our plans and specifications. If there are questions or if we may be of further service, please call. Sincerely, CHURCH and Associates, Edward O. Church, P. I 3772 , EOC/trp "'gvgi; Fly 2 copies sent copy to APEHD, Attn: Nancy MacKenzie copy to Aspen Digger, Attn: Jinx, 630 Stgne Load, Basalt, CO 81623 DENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 80033 CASTLE ROCK 303.660.4358 303.463.9317 Fax: 303.463.9321 EVERGREEN 303.816.1455 —7 T LOVELAND 970.663.2124 a 0 1.8 ACRES 7274 UPPER RIVER ROAD PITKIN COUNTY, COLORADO 558 SF OF INFILTRATIVE 3 GRAVELLESS BEDS EACH BED - I ROW OF AREA IN 0 DISTRIBUTION BOX \ WELL % 99 I �` / EXISTING DRAIN FIELD ONE -2000 GALLON TWO-COMPARTMENT PRECAST CONCRETE SEPTIC WITH AN EFFLUENT FILTER ON THE OUTLET FOLLOWED BY ONE 1000 -GALLON y SINGLE -COMPARTMENT SEPTIC TANK WITH A PUMP **41,*> \98 / I I I I PROPOSED 4 -BEDROOM RESIDENCE IRRIGATION DITCHES ARE 50 FEET EXISTING /N/� FROM THE DRAIN FIELD % 2 -BEDROOM CABIN UTILIZE EX EXISTING ♦� °/rC WELL IS 100 FEET FROM THE DRIAN FIELD AND / y DRAIN FIELD % EXISTING 1250 GALLON SEPTIC % TANKS *** OWS AS -BUILT DRAWING SCALE 1"=50' JOB NO. 12220 FIGURE 1 Ct RCH & Associates, c. ENGINEERS & GEOLOGISTS b&y4 2Wff Aspen Pitkin Environmental Health Department Attn: Nancy MacKenzie 130 Galena Street Aspen, CO 81611 Subject: Clarification Letter, Proposed Residence 7274 Upper River Road Pitkin County, Colorado Job No. 12220 Dear Ms. MacKenzie, This letter is to clarify errors in our OWS design for the subject site, dated April 24, 2000. The percolation rate for the proposed OWS is 7 minutes per inch (MPI). The area that is required for a drain field with a percolation rate of 7 MPI, four bedrooms, and a total square footage (SF) of 3500 SF, is 741 SF. Using a 301/6 reduction, we proposed three rows of I 1 chambers, for a total of 511.5 SF. All other recommendations in our OWS design should be followed. If there are any questions or if we can be of further service, please call. Sincerely, CHURCH & Associates, Inc. Tim R. Petz I copies sent fax copy to 303.526.5171, Attn: Jan fax copy to 970.927.160$, Attn: Nancy DENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 80033 CASTLE ROCK 303.660.4358 303.463.9317 Fax: 303.463.9321 EVERGREEN 303.816.1455 It ASPENIPITKIN EARONMENTAL HEALTH DEPARTMENT ISDS DESIGN CALCULATIONS Owner's Name Parcel ID # House Size (sq. ft.) (75 gpd, 100 gpd, or 130 gpd) 100 Number of Bedrooms in Main House Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House Number of Bedrooms in Detached Caretaker unit Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit (If the caretaker unit is ATTACHED, treat as if part of main house.) Average Daily Waste Flow 800 State Review Required? no Perc Rate (T) Design Flow (Q) = # potential bedrooms X 2 people/bedroom X gpd X 1.75 Q= 1400 Absorption Area (=Q/5 X SQRT perc rate) A = 740.81037 sq. ft. of absorption area required 48 gravelless chamber units without reduction # of Perc Holes Required: 3 1 in every soil type? Spaced uniformly over proposed area? A masmtm 30% reduction is allowed for use of deep gravel or gravelless chambered system, only if the lot size and soil conditions are optimal. If a reduction is being proposed, describe why lot size and soil conditions are optimal: A = 518.5 with reduction 33 gravel ss chamber units with reduction Type of system: []Absorption trenches []Absorption bed [] Gravelless chambers []Dry well []Seepage Pit []Other (type) Minimum tank capacity 1750 gallons SETBACK FROM WELL # of feet = 132 SETBACK FROM POND, STREAM OR IRRIGATION DITCH # of feet = 82 SETBACK FROM DRY GULCH # of feet = 57 / \ Printed on Recycled Paper IV ASPENIPTTKIN ENVIRONMENTAL HEALTH DEPAR• ENT ISDS DESIGN CALCULATIONS Owner's Name SCHO,Eal f t [ fl+l „ . „ , 'r Parcel ID # House Size (sq. ft) 200016000` (75 gpd, 100 gpd, or 130 gpd) 100 Number of Bedrooms in Main House 1 4 V Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House 0 Number of Bedrooms in Detached Caretaker unit 0 Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit 0 (If the caretaker unit is ATTACHED, treat as if part of main house.) Average Daily Waste Flow 800 State Review Required? no Perc Rate 7 (1) Design Flow (Q) = # potential bedrooms X 2 people/ bedroom X gpd X 1.75 Q= 1400 Absorptior Area Q/5 X SQRT) A = 741 sq. fl. of absorption area required 48 infiltrator units without reduction A maximum 30% reduction is allowed for use of deep gravel or gravelless chambered system, only if the lot size and son conditions are optimal. If a reduction is being proposed, describe why lot size and soil conditions are optimal: GOOD SOIL CONDITIONS, DOSING NARROW BEDS A = \/519 sq.fL with reduction 33 infiltrator units with reduction Type of system: UAbsorption trenches UAbsorption bed [x] Graveness chambers HDry wen nSeepage Pit 00ther Minimum tank capacity 1750 gallons SETBACK FROM) ELL # of feet = 132 REDUCTION PERMITS 100' SETBACK SETBACK FROM POND, STREAM OR IRRIGATION DITCH # of feet = , 82 REDUCTION PERMITS 50' SETBACK SETBACK FROM DRY GULCH # of feet = 57 FINAL INSPECTION BY: DATE: 0 0 Engineer's Submittal for Septic Permit in Pitkin County Owner's Last Name: SCHOEBERLEIN Location: 7274 UPPER RIVER ROAD Summary of information regarding new septic system: Type of system being proposed: SEPTIC TANK AND GRAVELLESS CHAMBERS Other treatment processes being used: NONE Does the system use any mechanical parts? (Prohibited unless there is no alternative)YFS If yes, explain why there are no alternatives A PUMP IS REQUIRED DUE TO ELEVATION DIFFERENCE FROM SEPTIC TANKS TO DRAIN FIELD Does the system require any maintenance other than routine pumping? YES If yes, who will do the maintenance? CLEAN FILTER WHEN SEPTIC TANK IS PUMPED Are any reductions being proposed? YES If yes, what makes the lot and soil conditions optimal? GOOD SOIL CONDITIONS AND DOSING TRENCHES Which of the following are on the site or within setbacks? Closest distance of septic system to each feature Q 100 year floodplain ) Q well(s) >100 FEET Q irrigation ditches >50 FEET Q streams >50 FEET Q ponds Q other features What was the profile hole depth? N/A What is the depth to groundwater? NL What is the depth to bedrock? N/A What assumptions, if any, were made in system sizing and design? (Include any local, site- specific data, such as months without snow cover, ratio of evaporation to absorption, etc. that are relevant.) AN 8 FOOT TEST PIT IS REQUIRED PRIOR TO DRAIN FIELD INSTALLATION. If there are any variations from normal design, please explain how they can be demonstrated to improve treatment and protect water quality. NONE JC) Rpr 04 00 01:31p William F Schoeherlein 303-526-5171 • fi'd 11f0► . i Pff[ON COUNTY ARE-ArFUCATION CONFERENCE SUM?"" � I� � � � P1ANN5R' Snenne-woltT DATE: lune 15, 1999 SMaeDeflem PROJECT: dtpsimraQve 1041 kiara'd Rreview dt fiMQS Eta IOCAT3@�f:.i7274Uppef RivwRcad OWNER- I pho.dFar. (303152l.BSOSiS2(,5L7L QR 923-2801 (P4) I Hari.d Revsen' d-GMQS fXcUlptim dop twt Applicant propses todemohsh 00-e124iagss'410 and tephct d e t�Mactrk semelauiauasticaristes�asidasm fnwdwww;cwwwdvwfm-improycmants,dle Adiel! b a baildmR envelope uamd the arcading and. popotrd imPtWmtmAt. Tfw budding cuvd )Pc silkseltb; y t041 d aet "MaPPd wiWlifiellabisal ffrsiss)a< Il lascaw Additional impaett ac, IC141 was (low MUMASNICINut im p"mwd h she pevio.s> .di/Wsbed arta). 11t budding to be deonolubod is ler 100 y:an old, but is noon pitltin Cornty Hivotic Lncw—y and a aeoosideted Cl4kk Gds the Stade dHissa is ces Pbr. f4lol 1 1 Land Use Cause Seotiaas{b addatsik bttw of sequsxtlappficatios: I Seet6634(X10 I Beard Review: TLe-ptoposedbuikUngmvdopedufl,itke+. avoid 1041 ha d:anroi 08 tot cteato additional 1041 imp"M in order to be d*" fox she ad,miaiWative ¢view'. ----,"3.150- GHQS-E2emptm to Reple.'.e a L 01Y FsabliAW SMUCIOM In osde+ to be eligiale 1« th Is tiem�tioq thcA licaet drR docm.snsl wbsys the tsr.ewreaas oowAnsHel sadtbat thetvre rasnplie w�1 the "dwe j mit"=dd,,77tfia-tion in �e Godo "...a s"rwe4yenleraWe Fwma taubisapoa of rooms, whi contain k;�nyc�bgtx batls hN'`inea asst whs6 tRdcsiFped for or an be 056M1asa resideocebY s single family orals, 'I� of `,,..j"', faesilieseegusests.- II SnQwW mfelow Azoning, wood) Crw& Cautus Yasiew by: V omm ity�oeat O recant _ S..a�—t�f+a wti c Plsmiog Fcaj To opply. tlre-fna"Aop iafoamati� utas voted 64ty—t: 1 II ; 1. falter of jxpjts4 CodeSecuous lived above; 2. 24" z 36`Site Plan - h mmpliacxmh the povisiwu of Sect' w 5--70.040 (anacb4 i t 3- foasust floor owner( m ptoce>;l application and asabatixiyl the repfCSeNativc (if;piiraWe)(1 m0Y% 4. Pasml dnrtsp , udmg kgd d=QiPIR Ud ve[Indy MAP S. Copy ctf t+rs;sn"M (I mPY) I 6. App !ot fro: 7. Pmofof TAis preapplFratioa erny�mxe awunary it advtsary in natre and wl binding on dee Cowry The vlJor iar pre° dad w dw satnaaiy is based canrem -mug simukrt6 and staff' 6nerpresubw s bused upon eeprescnsmion of the of- 0 April 27. 2000 JANET K. $cHOEBERLEIN 26064 CENTENNIAL TRAIL GOLDEN. OOLORADO 00401 1303) 52e-0606 Nancy Mackenzie Aspen/Pitkin Environmental Health Department 130 S. Galena St. Aspen, Colorado 81611 Re: Application for Building Permit 7274 Upper River Rd., Woody Creek 81656 Dear Nancy: I am enclosing the following. E Application for Individual Sewage Disposal System Exhibit A — legal description Site map House floor plans — 81 /2 a 11 Bacteriological test results for water supply from Aspen Consolidated San. Dist. Report on Well Permit 7576 from Colo. Div. of Water Resources Soil & Foundation investigation from Church & Associates Engineer's Submittal for Septic Permit in Pitkin County Check in the amount of $330 for Permit Fee Copy of Pitkin Cty Pre -Application Conference Summary Please let me know if you have any questions or require further information. Thank you for your assistance. Sincerely, ganetK. Schoeberlein 970-923-2801 Encls. ,uY • Exhibit A • i 9 uth, _ and 15a Section 9, Townsh P li tract of land situated in Lots l� Heridian, described as follo the Sixth Prinetp line o a a'cEroadway •43 Range 85 WQ5t Of i on the southwesterly Beginning at a p° of said SeC.ion'9 bearer o 08+ W. 240.83 feet; Vh¢nce the South l/4 7a7 feet; them the southwesterly line of feet; thenar S+ E-33 0.00 feet, to i point 8 60 feet, along the s�ttaaining thence S. 430 57 S. 490 58 E}}�e int of beginning. w�e�Eine of d public road walY to 1.75 acres 7ppYe oa less- those Prot4` i'*" restrictio2sand 0I ressly made subJect to recorded at Book ante is exp 116481, eRantnseuhicn appear in full at Document No. gage 362, of the Records of Pitkin CAuntY, 0 0 CHURCH & Associates, Inc. ENGINEERS & GEOLOGISTS April 24, 2000 Janet Schoeberlein 26054 Centennial Trail Golden, Colorado 80401 Subject: Subsurface Investigation and OWS Design, Proposed Residence 7274 Upper River Road Pitkin County, Colorado Job No. 12220 Dear Ms. Schoeberlein, As requested, we have investigated subsurface conditions at the site and designed an onsite wastewater system (OWS) for the proposed residence. Subsurface conditions were investigated April 18, 2000. Our firm conducted a Soil and Foundation Investigation for the subject site, and is presented under a separate letter. SITE CONDITIONS The site is in a rural residential area of Pitkin County, Colorado in the Woody Creek area. There is an existing 2- s, on the southern portion of the lot that is utilizing an 1197 square feet (SF) drain field. Due to the bunk beds, we are designating the cabin as based on three bedrooms. According to Pitkin County regulations a three-bedroom residence having less than 2000 SF and a percola- tion rate of 8 minutes per inch (MPI), requires 446 SF of drain field. The existing drain field, as indicated on Figure I is 1197 SF in area and appears to be functioning properly. The drain field is presently exposed for county inspection. The existing tank configuration is sufficient to serve the existing 3 -bedroom resi- dence. The proposed drain field area has relatively no slope and a moderate cover of native grasses. PROPOSED CONSTRUCTION A four-bedroom residence with living area of between 2000 and 6000 square feet (SF) is proposed at the location presented on Figure 1. We have sized the OWS based on four -bedrooms and 800 gallons per day (GPD) using Aspen/Pitkin Environmental Health Department (APEHD) loading of 100 gallons per day per person. The sewage loading with a peaking factor of 1.75 is 1400 GPD. This loading includes washing machines and a garbage grinder. SUBSURFACE CONDITIONS We performed a subsurface investigation by digging 4 percolation holes, 41 to 33 inches deep, and one profile pit at the location indicated on Figure 1. Subsurface conditions in Profile 1 consist of 6 inches of a sandy root zone; underlain to 2.5 feet by sandy, silty clay; underlain to the maximum depth explored of 8 feet by silty sand with gravel and -14%e cobbles. Percolation tests indicate percolation rates of 5 to 10 MPI. The average percolation rate is 9,W. . Percolation data is presented in Table I . J (� DENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 80033 CASTLE ROCK 303.660.4358 303.463.9317 Fax: 303.463.9321 EVERGREEN 303.816.1455 • Su fice Invesligalion and OWS Design Job No. 12220 Page 2 RECOMMENDATIONS The OWS includes one septic tank with a pump, and three chamber -type drain fields installed at the locations presented on Figure 1. The OWS design is based on an average sewage load of 800 GPD and a percolation rate of 8 MPI. We recommend the installation of one 2000 -gallon, two-compartment concrete septic tank with a pump in a biotube vault, as indicated on Figure 3. A pump is required due to elevation differences between the tank and the drain field. The air field requires the installation of three chamber - type trenches, each trench having one row f i2 chambers. distribution box is required to control effluent flow to the fields. We recommend a design ftow rate o -gallons per minute and a total dynamic head of 18.9 feet. Pump details are presented on the pump curve. Based on subsurface conditions, topographic positioning of the well and irrigation ditches, and the casing of the well, we believe setback distances can be reduced. The setback distance from the irrigation ditches and the well can be reduced to 50 feet and 100 feet respectively. The resultant flow from the drain field will be away from the well and the irrigation ditches and contamination of these by the OWS will be prevented. An eight -foot test pit is required during "spring runoff' and prior to OWS installation to confirm ground water and soil conditions. The county and our firm must be contacted to observe the test pit. Movement over the drain field area during construction should be kept at a minimum to prevent compaction of the receiving soils. We recommend the bottom of the bed be scarified with a pick, shovel, or backhoe bucket teeth prior to the addition of chambers. We recommend the surface of the fields be seeded after installation of the fields. We recommend using a native seed mix available at seed stores. These mixes do not require irrigation and develop a growth 10 to 15 inches high. No automatic sprinkler system should be installed over the fields. OPERATION AND MAINTENANCE The owner must realize an OWS is different from public sewer service. The owner must be aware of and assume responsibility for maintenance of the system. In the absence of a monitoring program, we recommend the septic tank be pumped every two years. Effluent filter and screened vaults, as applic- able, are to be cleaned during pumping. There are daily considerations such as not putting plastic or other nonbiodegradable materials into the septic system. Garbage disposal use should be minimized. The backwash of a water softener may be harmful to the OWS. A separate drywell should be constructed for the backwash waste, if a softener is installed. Chemically treated water from a swimming pool or spas should not be introduced to the OWS. LIMITATIONS A contractor who is experienced in OWS installation should install the OWS design. Our investigation, layout, design and recommendations are based on data submitted. If subsurface conditions considerably different from those described in this report are encountered, we should be notified to evaluate the effect on the proposed OWS. If the health department makes modifications to this design, we should be contacted to evaluate the impact on the performance of the OWS. The county and our firm must be contacted upon completion of the OWS 17 • Subace Investigation and OWS Design Job No. 12220 Page 3 All construction is to be in accordance with the ISDS regulations. Pipe type and size, burial requirements, septic tank construction, and other specifications, which are not depicted in our report, are to conform to the requirements of the ISDS regulations. The installer of the system is to have demonstrated knowledge of the APEHD ISDS regulations and requirements. If there are any questions or if we can be of further service, please call. The project manager for this site is Tim Petz. CHURCF Edward C EOC/trp 3 copies sent I'k 0 1.8 ACRES 7274 UPPER RIVER ROAD prMN COUNTY, COLORADO 558 SF OF INFILTRATIVE 3 GRAVELLESS BEDS EACH BED - I ROW OF 12 AREA IN CHAME 0 /• P-1 lop \j moi. P-3 -ti DISTRIBUTION BOX WELL ♦ ee I TWO 1250 -GALLON EXISTING SEPTIC TANKS FOLLOWED BY 1197 SF OF DRAIN FIELD ONE -2000 GALLON TWO-COMPARTMENT PRECAST CONCRETE SEPTIC TANK ' so -,--WITH PUMP IN BIOTUBE VAULT Asa 4* I I I I PROPOSED 4 -BEDROOM RESIDENCE IRRIGATION DITCHES MUST BE 50 FEET ` EXISTING FROM THE PROPOSED DRAIN FIELD OR THEY ♦ 2 -BEDROOM CABIN / 4Ti� O MUST BE LINED OR CULVERTED ♦` TO UTILIZE EXISTING I� VACy WELL MUST BE 100 FEET FROM THE DRIAN FIELD AND / PROPOSED DRAIN FIELD ♦ EXISTING ♦ 1250 GALLON SEPTIC TANKS ♦♦ �e SITE PLAN, LOCATION OF PERCOLATION HOLES, AND LOCATION OF PROPOSED OWS JOB NO. 12220 SCALE 1"=50' FIGURE 1 • TYPICAL PLAN VIEW - N.T.S. 4" SDR 35 PERFORATED PVC PIPE PLACED ON GROUND ACCORDING TO MANUFACTURERS SPECIFICATIONS C 3' 4" SDR 35 PVC OBSERVATION/VENT PIPE TYPICAL CROSS-SECTION - N.T.S. 3' 4" SDR 35 PERFORATED PVC PIPE PLACED ON GROUND ACCORDING TO MANUFACTURERS SPECIFICATIONS 0 4" SDR 35 PVC OBSERVATION/VENT PIPE WITH CAP LL EXTENT OF EXCAVATION EFFLUENT INLET _ (1/8" PER FOOT DROP) GRAVELLESS CHAMBER 3' BY 6.25' TOTAL - THREE TRENCHES SLOPE F - MIN. OR DRAINAGE `' 1.5' MIN GRAVELLESS CHAMBER 3' BY 6.25' CALCULATIONS AND SPECIFICATIONS DESIGN CRITERIA RESIDENCE — 4 BEDROOMS, 2000-6000 SF LOADING — 100 GAL/DAY/PERSON TOTAL LOADING — B00 GPD PERCOLATION TEST — 7 MPI AREA — (1.75 X Q XRT)/5 AREA — 792 SF hyo REDUCTION FOR USE OF CHAMBERS — 30% TOTAL AREA — 555 SF 5iy LEVEL MANIFOLD STRIBUT10N BOX EFFLUENT LINE TO THIRD TRENCH TYPICAL DISTRIBUTION BOX - N.T.S. TRENCH SPECIFICATIONS NUMBER OF TRENCHES — 3 LENGTH OF EACH TRENCH — 75 FEET, 12 CHAMBERS WIDTH OF EACH BED — 3 FEET, 1 CHAMBERS TOTAL NUMBER OF CHAMBERS — 36 CHAMBERS TOTAL AREA — 558 SF DRAIN FIELD DETAILS l 3' APPROX. PLAN VIEW Im I CONCRETE DISTRIBUTION BOX �,__4" SDR 35 PVC PIPE ONLET INLET OUTLET VIEW VIEW • MINIMUM OF FOUR OUTLETS NEEDED OUTLET TOTAL CAPACITY — 1.75 X 0 X (30 HOURS/24 HOURS) _ 1750 GALLONS RECOMMENDATION — ONE 2000 GALLON TWO COMPARTMENT PRE—CAST CONCRETE SEPTIC TANKS WITH A PUMP IN A BIOTUBE VAULT FIGUR " TO 8" 1.5' A PROX. 1' APPROX. INLET OUTLET VIEW VIEW • MINIMUM OF FOUR OUTLETS NEEDED OUTLET TOTAL CAPACITY — 1.75 X 0 X (30 HOURS/24 HOURS) _ 1750 GALLONS RECOMMENDATION — ONE 2000 GALLON TWO COMPARTMENT PRE—CAST CONCRETE SEPTIC TANKS WITH A PUMP IN A BIOTUBE VAULT FIGUR 40M1..i CHURCH & ASSOCIATES, INC. Effluent Pumping System Orenoo Systems* 20004ALLON TWO COMPARTMENT PRECAST CONCRETE SEPTIC TANK WITH A PUMP IN A BIOTUBE VAULT l" rponftd Fibarrggloo Gosketed Lid with Stainton Steel Bolts Slope Ground Away from Meer Inlet Tee Conduit Seal Conduit to— Height Varies 18' Winimum Disclosure. The owners of Church & Associates, Inc. also own S.C.G. Erderprisee, Inc, which distributes Orenco Systeme Inc. products Patents 14,439,323 i 5,492,835 Foreign Patents Pending G 1997, Orenca Systems, Inc. Job No. 12220 SEK PVC PVC Riser with Grommet(s) ice Box (bond to tank adopter with recommended odhol e) WC Splice Box with Cord Gripe f. Discharge Assembly Fkodble Hose Effluent Discharge Tank Adapter (cost or bolted) c Hann 6 _1—.j r,..a..0 FI„M On/Off Redundant Off W/Alarm Check Valve (optional) Voult Inlet Porta 1/8' Weep Flow Inducer Hole Effluent Pump Filter Cartridge Drain Port Effotubedl Pump Voult EDW—TD-3 Rev. 1.0 (2/98) FIGURE 3 • • 0 0 0 N m U U C C � %J' g N O O 11loll O II11111I O ~ Q =I;11 11 N > @ W N III N LL Ism U y N d 111 loll W Z o loll Hill 0 LL 01 0« O M 3 L co J m o v W Q = S H N 61 y x O 0 q �... 1�.��..�.111 m = :1 ,. .mi 1.9.I IN 1111 ■ 1 long 11111 111■■■■■ .■. ll op 11 .�I•.■loll R.9 .■.ri.i■.■■ 1 o ■■I Isom 11111 Ism 1199 io:.il.: ■1=1111..■ ...■■.■■■ sling on 1■1../I �..:':.11i111i ■.1 - ■►,. py - still ■o1%.1 - oulm■ol■■■ .II.■l..m■....1■.. Woollom 111. 1 ■■.■llCllll� • 11011 on looms 111 ►■; 1.:. ■.1 ►�■.losing l 01■ ■i/■ . llllll■:ll:1111■ ■■l .loll. - I�.. _ ... .= �........■lOil ;. �■n loll ;.. _ r""' iemongolil.■■l:INN on I 1 1:- 0 N m U U C C � %J' g N O O O O� O ~ Q LD N > @ W N C N LL o g WQJ 1H41] WOH C�I�0 RPI u o o b o m n o o Lo@ m N O til O O 0 h 0 m jE M a �Z E ~ Q w d d > rG W CL LL 3 U y N d W Z o N Z 0 LL 01 0« O M 3 L co J m o v W Q = S H N 61 y x O 0 q m = x 0 h 0 m jE M a �Z E Profile: TAE 1 - PERCOLATION TEST RESTS 7274 UPPER RIVER ROAD DATE OF TEST: 4/18/00 PITKIN COUNTY, COLORADO feral rincerintinn o- 1' (OPSOIL, SANDY, SILTY, ROOT ZONE V- 2.5' CLAY, SANDY, SILTY, STIFF. MOIST, RED/BROWN 2 5'- 8' SAND WITH GRAVEL AND GOBBLE, SILTY, DENSE, MOIS I RED NO BEDROCK OR GROUNDWATER PRESENT HOLE DEPTH TIME NUMBER OF HOLE, INTERVAL (INCHES) (MINUTES) AVG DEPTH DEPTH CHANGE, INTERVAL HOLE START, END, (INCHES) PERC PERC. (INCHES) (INCHES) RATE (MPI) RATE, IMPII 2 35 10 350 600 2.50 4 10 1 00 250 1 50 7 10 150 262 1.12 9 10 1 25 250 1.25 10 262 462 2.00 5 8 10 125 275 1.50 7 10 275 425 1.50 7 10 125 275 1 50 7 7 3 33 10 4.50 5.50 1.00 10 10 1 00 250 1 50 7 10 4.25 6.00 1.75 6 10 1 25 250 1.25 8 10 2.50 375 1,25 8 10 175 300 1 25 8 8 NUMBER OF HOLES: 4 AVG PERCOLATION RATE (MPI): 7 Joh No. 12220 Profile: TARE 1 - PERCOLATION TEST RESTS 7274 UPPER RIVER ROAD DATE OF TEST: 4/18/00 PITKIN COUNTY, COLORADO faaf dasrrinfinn 0- 1' TOPSOIL, SANDY, SILTY, ROOT ZONE 1'- 2 5' CLAY, SANDY, SILTY, STIFF. MOIST, RED16ROWN 2 5'- B' SAND WITH GRAVEL AND COBBLE, SILTY, DENSE. MOIST RED NO BEDROCK OR GROUNDWATER PRESEN T NUMBER OF HOLES: 4 AVG PERCOLATION RATE (MPI): 7 Job No. 12220 AVG. HOLE DEPTH TIME DEPTH DEPTH CHANGE, INTERVAL HOLE OF HOLE, INTERVAL START, END, PERC PERC. NUMBER (INCHES) (INCHES) (MINUTES) (INCHES) (INCHES) RATE (MPI) RATE, (MPII NUMBER OF HOLES: 4 AVG PERCOLATION RATE (MPI): 7 Job No. 12220 0 0 CHURCH & Associates, Inc. ENGINEERS & GEOLOGISTS March 10, 2000 Janet Schoeberlien 26054 Centennial Trail Golden, Colorado 80401 Subject: Soil and Foundation Investigation, Proposed Residence 7274 Upper River Road Pitkin County, Colorado Job No. 12220 Dear Ms. Schoeberlien, As requested, we investigated subsurface conditions utilizing test pits dug at the subject property on February 22, 2000. The purpose of our investigation was to evaluate subsurface conditions at the bearing level of the proposed residence. The site is a 1.75 -acre parcel located in a rural -residential area in Woody Creek, Colorado. There is an existing residence with a partial basement in the location of the proposed residence that will be demolished prior to new construction. The proposed residence will be a 2 -story structure with a full basement and wood frame construction. Relatively light loads are anticipated. Two test pits were excavated using a rubber tire backhoe, as indicated on Figure 1. Subsurface conditions in Test Pit 1 (TP -1) consisted of 6 inches of topsoil, underlain by very silty clay to 4 feet, underlain by sand with cobbles and gravel to the maximum depth explored of 9.5 feet. Subsurface conditions in TP -2 consisted of 6 inches of topsoil, underlain by very silty clay to 4 feet, underlain by sand with cobbles and gravel to the maximum depth explored of 8 feet. The results of laboratory testing are attached as Figures 2 through 4. The hand drive taken from TP -2 was a sample of silty clay and exhibited a 2.6% consolidation wetted under a surcharge pressure of 1000 Pounds Per Square Foot (PSF). The hand drive taken from TP -1 had a moisture content of 4.01/o. A bulk sample was taken from TP -1 at 8 feet and had a fines content of 14 percent. The results of our observations and laboratory testing indicate a spread footing foundation system is appropriate. Spread footing supported by sand and cobbles should be designed for a maximum allowable bearing pressure of 2500 PSF. Footings should bear on the native undisturbed sand and cobble, beneath the silty clay zone, at minimum depths of 4 feet. Areas in which material is disturbed or where existing foundations have been placed, must be excavated to native soils. The sand and cobble have nil expansion potential. We believe four feet of frost protection is necessary. We recommend an exterior foundation drain be installed around the basement foundation to discharge into a sump pit or to be daylighted away from the residence. A detail of the subsurface drain is presented on Figure 5. .DENVER 4501 Wadsworth Boulevard Wheat Rldge, CO 80033 CASTLE ROCK 303.660.4358 . c _ 303.463.9317 Fax: 303.463.9321 EVERGREEN 303.816.1455 Soil and foundation Invcsligation • • Job No. 12220 Page 2 Any soil loosened or disturbed during foundation construction should be removed prior to placing concrete. Excessive wetting or drying of the subgrade should be avoided during construction. We appreciate the opportunity to be of service on this project. If there are any questions or if we can be of further service, please call. Sincerely, Pip REGI CHURCH & As �e'4r�O.Cy T G9� v •o 13 7 s Edward 0. Churc •-. I3- (U_ ss/ONAL EN EOC/trp 3 copies sent fax copy to 303.526.517 1, Attn: Janet 727.4 UPPER RIVER ROAD PITKIN COUNTY, COLORAW 0 -- -- -- -- -- EXISTING CABIN I1 ' EXISTING RESIDENCE ' TO BE REMOVED 20' TP -1 TP -2 ' rn in UPPER RIVER ROAD SITE PLAN AND LOCATION OF EXPLORATORY PITS JOB NO. 12220 NOT TO SCALE FIGURE 1 10 ,3.{SI-Lk - ig1 ROOTZONE, SANDY, SLIGHTLY SAND WITH COBBLES AND GRAVEL, DENSE TO ® MOIST, DARK BROWN/RED VERY DENSE, MOIST, RED/BROWN/UGHT BROWN CLAY, VERY SILTY, SANDY, MEDIUM STIFF, MOIST, RED/BROWN NOTES: WC = MOISTURE CONTENT % DD = DRY DENSITY -200 = PERCENT PASSING THE -200 SIEVE I DEPTH AT WHICH SAMPLE WAS TAKEN TEST PITS WERE EXCAVATED WITH A RUBBER TIRE BACKHOE ON FEBRUARY 22, 2000 LOGS OF TEST PITS JOB NO. 12220 D� FIGURE 2 TP -1 TP -2 oll HAND DRIVE WC = 4 HAND DRIVE -200 = 59 WC = 11.4 06 00DD = 99 o° 00 -200 = 59 o° o° o, BULK -200 = 14 10 ,3.{SI-Lk - ig1 ROOTZONE, SANDY, SLIGHTLY SAND WITH COBBLES AND GRAVEL, DENSE TO ® MOIST, DARK BROWN/RED VERY DENSE, MOIST, RED/BROWN/UGHT BROWN CLAY, VERY SILTY, SANDY, MEDIUM STIFF, MOIST, RED/BROWN NOTES: WC = MOISTURE CONTENT % DD = DRY DENSITY -200 = PERCENT PASSING THE -200 SIEVE I DEPTH AT WHICH SAMPLE WAS TAKEN TEST PITS WERE EXCAVATED WITH A RUBBER TIRE BACKHOE ON FEBRUARY 22, 2000 LOGS OF TEST PITS JOB NO. 12220 D� FIGURE 2 3q 0 CHURCH & Associates, Inc. Engineers & Geologists Denier Colorado, 303463-9317 rvutpeeu Colemdo, 303-916-1455 Castle Rwk, Coluntdo 303-6604358 Gradation Test Results a200 #100 450 a30 a16 48 a4 0 3B' 3u' 1-12' 3' 0.01 01 1 10 Dh melee of Particle hi Ml6imetem DESCRIPTION: Sand with Cobbles and Gravel 0 00 100 GRAVEL 21% HOLE / SAMPLE TP -I @ 8' SAND 65% DEPTH FINES 14% LIQUID LIMIT N/A PLASTICITY INDEX N/A DRY DENSITY (pet) N/A i �inH vii i u I► iii IIl .���ini� i�Nl l ildilli m �l 111111111, MIN 1 0.01 01 1 10 Dh melee of Particle hi Ml6imetem DESCRIPTION: Sand with Cobbles and Gravel 0 00 100 GRAVEL 21% HOLE / SAMPLE TP -I @ 8' SAND 65% DEPTH FINES 14% LIQUID LIMIT N/A PLASTICITY INDEX N/A DRY DENSITY (pet) N/A DATE: 3/10/00 JOB NAME: Schoeberlien JOB NUMBER: 12220 FIGURE 3 s 7 6 5 5) -6 -q 0 0 CONSOLIDATION UNDER CONSTANT PRESSURE DUE TO WETTING 1 10 APPLIED PRESSURE - ksf Sample of SILTY CLAY, TP -2 @ 3 FEET Natural Dry Unit Weight =11.4 % Natural Moisture Content = 99 PCF 100 JOB NO. 12220 SWELL - CONSOLIDATION TEST RESULTS FIGURE 4 �_� BACKFILL M IRAFI 140N OR EQUIVALENT GRAVEL: MINIMUM GEOTEXTILE FABRIC I CUBIC FOOT OF GRAVEL PER LINEA FOOT OF DRAT ----a • 0 O O D0 0.0;x. °0 • a O •4• U 0:'% O yi � o 0006 O Q � 0 i 6" MIN ..o• a Q 0C.O Qo. o h 00—$ ❑4 0 12 MIN. ,o•op:; • INSTALL DRAIN 1 ABOVE LINE JOB NO. 12220 J NOTES: GRAVEL SPECIFICATIONS: CLEAN WASHED GRAVEL 100% PASSING 1.5' 60-100% RETAINED #4 MAXIMUM 3% PASSING #200 POLYETHYLENE SHEETING •1• >PERFORATED 4 INCH DIAMETER PVC MIN. PIPE SLOPE OF 1/8' PER FT FOR SOLID PIPE AND 1/4' PER FT FOR FLEXIBLE PIPE I. DRAIN PIPE SHOULD LEAD TO SUMP OR POSITIVE GRAVITY DISCHARGE. 2. WRAP GRAVEL COMPLETELY IN AREAS OF SANDY OR SILTY SOILS. 3. DRAIN SHOULD BE A MINIMUM OF 12 INCHES BELOW SLAB AT HIGH POINT. 12 MIN. TYPICAL EXTERIOR BASEMENT WALL DRAIN FIGURE 5 to 0 } f) C 3 8Ol 3 i G 5� e a 12.50 CALL vi T, (-o CcH:DqeTmr yr I+f ����CP CDh'tfi£ 7Trc Tl,r1:G U/fThl %-' R1$E,Q,� Qy lviflN}IO(�S DM se�rr� K wiry &Vf— 8 �N N�oc_E ABA IJ F `' 14ETAL T/W k' �V,r„�-��^e:ftonK-QI Igo -k: �q�� /I �( s e co p. Taav� —t vi y i �{.le+&'. 118Y, $ f' 1 i � CAbd L�-WELL Sent By: ACSD Wastewater Facility; 9709257278 �1 � i Apr -27.00 12:18; Page 212 STANDARD BACTERIOLOGICAL WATER TEST ASREIL C0119OLIDATED SAXIMArm MSTRICT Oft SERIAM CENTER DRIVE AWM COLORADO 11111 SAANETAREM. DATE tTAi 7!2.'lA/jJ 1 ) COMMUNITYSIwRY ( 1YSTTA &Mty I I NCNCOWAWTY ( I CHECK � j I ) PROCESS WATER 1 ) OTHER P°9LC ( 1 HAW I ( ) SURFACE ( J,ir(eL'ATE ( I SREpAL NM'LC 8"MOTALL WWMTM KIDT LN/nRiF MTHIMAIYIE WILL IN! N7CAAawRETLM To REVARK FECAL ABSENT PRESENT ZI - SEE votx-TIDIM OR 8ACR PAQE - RF9IATS WDN 0 E 0R vAw cDUFOLi15 WMREVOW FOR TIEL TIONS, SAWLiND IN5TRUDTIDN$AIID DETHATIDNS PERIOD ML MICATE NON.00MPLWXE WRHMNAR) DRVVMwATERSTMgARD5. FOR TEST g Al as RPR -26-2000 15:59 REPORT DATE Wad Apr 26 15:29:46 MDT 2000 r Receipt 9116835 Permit 7576 Div 5 Wd Basin Md Engineer User RUSSELL WILLIAM Address Proposed 0 0 Actual 30.00 WOCREEK Telephone acres Case Permit XRef 0 Well Name County PITKIN 010 040 NW 0160 SW Sec 9 Ts 9 South Rng 85 West Pm Sixth 38 0 State Co DIV 5 WTR RESOURCES OLORADO WELL APPLICA l IONS OLORADO DIVISION OF WATER zip 81656 Subdivision Filing Block Lot Parcel Size PIN 0 Main AcOVnY Interim Status Last Action Permit Issued Permit Expires Expire Notice Sent Well Const Report Well Const Complete Well Report (Non Crib) Pump Install Report Pump Install Complete 1st Beneficial Use 12-04-1960 Statement Benef Use Benef Use (Non -crib) Abandonment Report Well Plugged DOMESTIC 1 -AjJ ttlo ] 1� r. Gc�ew V I'hRMIIS Pump Rate Ann Amt Proposed 0 0 Actual 30.00 0 Irrigated Area 0 acres Elevation 0 Pert Casing Top 0 Perf Casing Bottom 0 Water Level 57 Aquiferl Aquifer2 Driller Pump Installer Statute Meter Log Dual AbReq No No No No Comment Depth 0 76 APR -26-2000 15:59 DIV 5 WTR RESOURCES 1 30S Ebb 5415 r.W/04 form .No. taw$ -t t 4M9 STATE OF COL OFFICE OF THE STA GItffER 818 Centennial Bldg„ t"13 SL, Denver, CO 80203 (303) 886-3581 Fax (303) 8811-31M For Omte Only i CHANGE IN OWNERSHIP/ADDRESS CORRECTION OF THE WELL LOCATION ` j Insert the Well Permit Number %'5-,76 and welt NAME(S) �7 ! e�//\�. ScC- 1 d Q V, If your well has an absolute weer riaM decreed well by the court and thewwell iss not registered with the � ////4 Mailing Addresses 6 ( � ? I7 / 4..t2 �rQ i J �O ,�_ // CRY, SL Zip /qy n n s > 0 �V� Some Ertweheer. Enter the WaterCoon Cate Number / Civil Action Number and well number as decreed. Phone D O -75'- This This form is filed by the named indiuidwYenBty claiming that they are the owner of the well Pertmhed as relemnoed above. This MM is made pursuant to C.R.S. 37480.143. 1 WELL LOCATION: t;,wrnty // YL Owner's 1Mell Designation e—/6S6i ) V pp) /(Addy I(S�tate) / . or U , Range 0 E. or L� V11., (O "' P.M. I I W 114 of theEVIM, Sec. Twp. �D NS. Distance from Section Lines FL From O N. or S., FL From 0 E. or 0 W. Line I Subdivision Name `Lo- caii- Lot . Block FilromAinit The above listed owner(s) say(s) that he, she (they) own the well described herein. The existing record is being i amended for the following reasons. L thange in name of owner ❑ Change 4h mailing address j jO Correction of location for exempt wets permitted prior to May 8, 1972 and nonexempt wells permitted after I May 17. 1M. Please see the reverse side for fulfner htfonnation regardmmg correction of the well location, I (we) claim and say that I (we) (are) the owner(s) of the well described above aro that the conlmenoamenl of extraction of ground water from tris well W&*My made under the well permit, occurred on the date indicated. and OW the statements trade herein are true to my (our) knowledge. print the Swow p Name a Title Sin (s) or Me newer. I Dab ft o Uro responsb,My ofthe new owns mf to wN b cwriplsla and syn the tomb. siynatum d agents are gocq We if an I origkW %Nm of aperay signal by the ower s atached to the form upon its receipt. rorotsoeueohr Sone blot: JO 0 LEGEND & NOTES FOUND SURVEY MONUMENT REBAR WITH CAP AS NOTED O FOUND AL. CAP FOR THE SOUTH 1/4 SECTION 9 'LS 15710' BOOK 746 PAGE 202 WAS THE ONLY RECORD INFORMATION FURNISHED TO THE SURVEYOR. NO TITLE SEARCH WAS DONE BASIS OF BEARINGS 1/4 COR TO FOUND REBAR AS SHOWN IRRIGATION DITCH - WIRE FENCE OVERHEAD ELECTRIC LINES ,o TELEPHONE / POWER POLE $ WOOD FENCE ELEVATION DATUM IS ARBITRARY BASED ON T.B.M. - 100.0' SET STEEL SPIKE AS SHOWN, CONTOUR INTERVAL IS ! FOOT gg 6 SPOT ELEVATION LEGAL DESCRIPTION A TRACT OF LAND SITUATED IN LOTS 13 AND 15, SECTION 9. TOWNSHIP 9 SOUTH. RANGE 85 WEST OF THE SIXTH PRINCIPAL MERIDIAN. DESCRIBED AS FOLLOWS: BEGINNING AT A POINT ON THE SOUTHWESTERLY LINE OF A PUBLIC ROADWAY WHENCE THE SOUTH 1/4 CORNER OF SAID SECTION 9. BEARS 5.40.48'E. 1.636.43 FEET: THENCE S. 42.31'W. 367.27 FEET: THENCE N. 36.08' W. 240.83 FEET THENCE N. 43.57'E. 310.00 FEET. TO A POINT ON THE SOUTHWESTERLY LINE OF SAID PUBLIC ROADWAY: THENCE S. 49.58'E. 228.60 FEET, ALONG THE SOUTHWESTERLY LINE OF SAID PUBLIC ROADWAY TO THE POINT OF BEGINNING CONTAINING 1.75 ACRES MORE OR LESS. COUNTY OF PITKIN STATE OF COLORADO CERTIFICATION I. DAVID W. McBRIDE. A REGISTERED LAND SURVEYOR IN THE STATE OF COLORADO. HEREBY CERTIFY THAT THIS PLAT WAS PREPARED FROM A FIELD SURVEY PREFORMED UNDER MY SUPERVISION IN JUTA EX . 199- AND IS TRUE AND CORRECT TO THE BEST 0 DGE AND BELIEF. THIS CERTIFICATION IS VOID UNLWEY�rl,,, ON AN ORIGINAL BLUEPRWW.T. o'GlSlcp'•op'G SIGNED TH1S ?L DAY OF I 16129 [, • yaRwlm ltmw �Mff ACCORDING TO COLORADO LAW YOU MUST COMMENCE ANY LEGAL ACTION' BASED UPON ANY DEFECT IN THIS PLAT WITHIN THREE YEARS AFTER YOU FIRST DISCOVERED SUCH DEFECT. IN NO EVENT. MAY ANY ACTION BASED UPON ANY DEFECT IN THIS PLAT BE COMMENCED MORE THAN TEN YEARS FROM THE DATE OF THE CERTIFICATION SHOWN HEREON. SCALE I INCH - 20 FEET 30 40 1/4 CORNER ON 9 CAP '15710- SITE/TOPOGRAPHIC SURVEY SCHOEBER LEIN TRACT OF LAND IN SECTION 9. TOWNSHIP 9 SOUTH. RANGE 85 WEST 6th P.M.. PITKIN COUNTY. COLORADO PREPARED BY ASPEN SURVEY ENGINEERS 210 S. GALENA STREET P.O. BOX 2506 ASPEN. COLO. 81611 PHONE/FAX (970) 925-3816 JOB NO 231048 INC. PROPOSED HOUSE ADDED 3-20-00 JUNE 22, 1999