0 a
Aspen/Pitkin Environmental Health Department
Permit for an Individual Sewage Disposal System
130 S. Galena St. Aspen, Colorado 81611
Phone 970-920-5070 / FAX 970-920-5074
Permit # ,z p p/ (o Parcel ID #
2643-093-00-009
Type of permit New( X) Repair( ) Addition to House( )
Name of Owner Janet Schoeberlein
Street Address 7274 UDDer River Rd. Woodv Ck
Property legal description
Size of lot 1.8 acres Total square footage of the house 5,300
Water source Private well
# of bedrooms in house 3 # of offices, lofts & similar sized rooms in house 1
Caretaker unit Total square footage of the caretaker unit
# of bedrooms in caretaker unit # of offices, lofts & similar sized rooms in caretaker unit
Designed for what If rooms (list) (4) FOUR = 3 bedrooms and 1 office
Permit information
Designed by Church & Associates, Inc
Mailing Address 4501 Wadsworth Boulevard, Wheat Ridge, CO 80033
Perc rate 7 Profile hole depth 8 ft Depth to groundwater or bedrock 8 ft **to be reconfirmed
Septic tank capacity 1750 minimum Absorption area 741 sq ft, 30 % redu.for infiltrator = 519 sq It
Septic permit approved per compliance with the engineer design and specifications dated April 24, 2000 and
Clarification Letter dated May 4, 2000. Any changes must be approved by this department and the design
engineer prior to them being made. This department and the engineer design require that no work can be
done under this permit until ground water level is confirmed during the months of highest runoff and
ground saturation.
Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin
County ISDS regulations. The engineer has stated that the setbacks from the irrigation ditches and well can be
reduced and contamination by the ISDS will be prevented.
The design is for one 2000 gallon two-compartment concrete tank with a pump in a biotube vault. There are 3
trenches with'14 gravelles chambers in each trench for a total of 93 chambers.
This department does not endorse any brand of products.
The engineer must do a final inspection of the installation and submit an as -built letter to this department. This
department must also be called for an inspection with a minimum of 48 hours advanced notice.
Permit approved by: /SLY Date:
Plans and specifications of the oposed individual sewage disposal system have been reviewed and are considered
satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin
County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was
issued unless system construction has commenced or an extension has been approved in writing by the Department.
As -built dra ngm
s ust be included with this
( �aInstaller:
�n
r
Inspection
before the final approval will be issued.
Date:` D A frL&D
0
Hak4.P
1 Dud 34l c�tv
dosiry5 �iam.de�-�
v
„
T"
Ne -W 7o i� srui/ ri SeYS
Tv
ASP/PITKIN ENVIRONMENTAL HEALTH DEPARTMENT
APP ION FOR INDIVIDUAL SEWAGE DISPO* SYSTEM
130 S. Galena St.. Aspen Colorado 81611
Phone 970-920-5070/Fax 970-920-5039
Permit 8 Parcel ID #
Permit For. New Ihis station ( Repair
Name of OWNER IZy70
Street Address ? r ✓fir '
r r—
Owner's Marling Address �.S n_0 / D D a
Business Phone: 30 -,Soo -O Home Phone 0 Y oZ a Rxel
Legal Description: Lot ,Block _
/
Size of lot /'e. � acres Type of proposed structure:
Total areaaiwng space (sq. 8): J . -5 O V #1A Bedrooms, offices -and similar size rooms.
Primary Contac Person ^` /�� l7 V,611
1/ ' '—
Contact Mailing Address � � oC] �( �,� ��/�l /i / rL(.0 7 ✓Q,/r
well ( )Spnng ( )Stream ( ) Community/Pubbe (Name of System)
Is Proof of Adequate Water Attached (Required l ? (AjPes ( ) No (A water quality test and wall pump test or approval letter from community system)
Has this project been approved by Pitkin County 7 (y4es ( ) No
Is a Copy of the floor plan attached ( Required ) ? W i es ( ) No
Is a Coov of the site Dian attached
Application for an individual sewage disposal system is hereby submitted. I hereby candy that the above Information is true and accurate and that I have provided Irue and
accurate information oD locations of all existing and proposed wells, contour intervals, buildings, property lines, ditches, slopes, waterlines, springs. suction or irrigation lines,
drinking water cisterns, drain tiles, irrigation ditches. lakes, water courses, streams. noodplains, dry gulches. and existing septic systems. I acknowledge that any false or
incomplete information will invalidate the application and any subsequent permit. Issuance of the permit does not imply the approval of any other permit required for construction
pursuant to Pitkin County codes. No cons el'on may be undertaken until all approvals and permits have been obtained. The owner assumes all responsibilities in rase of failure
or inatlequacy of this system. _
Signature of applicant Date ZG'axt)
-----------------
For department use below
PERMIT FOR INDPADUAL SEWAGE DISPOSAL SYSTEM
Desion Criteria of system to be Installed (Any changes must be submitted and approved in writingt
Perc Rate min per inch Profile Hole Depth feet
Septic tank capacity: gallons Absorption areai sq. ft.
An Inspection is required prior to backfill of any component of the distribution system.
Design by Engineer Required ? ( ) Yes ( ) No All plans and specifications of the engineer must be followed. Any changes must be approved by the
AspeNPitkin Envirommital Health Department in writing and the engineer must certify the final installation to the Environmental Health Department in
wnling.
Permit approval by: Date
Plans and speufirabons of the proposed individual sewage disposal system have been reviewed and are considered satisfactory. Penrlissort is hereby granted to the owner or
the agent to perform the work indicated In accordance with the Pekin County ISDS Regulation in effect M the time of issue. This permit becomes invalid 6 months from the date
that the permit was issued unless system construction has commenced or an extension has been approved in wining by the Department.
As -Built drawings must be included with this permit before the final approval will be issued.
Installer:
Receipt #
Date received
Received by
Site Plan Well Permit and
Floor Plan Water Quality Test or
Comm Dev Approval Water System Letter
Final Inspection Approval: Date:
p 5-d2 6 4 ;Loma
_ Soils Test
_ Date Info Complete
Final Insp Requested
•PEHD 1.
Feb 07 01 10:23a
Accnrrintac
February 7, 2001
Jan Schoeberlein
26054 Centennial Trail
Golden, CO 80401
ENGINEERS & GEOLOGISTS
P.
'2&L/3-0�'3-0v --007
Subject: [.'valuation of Existing OWS, Proposed Schoeberlein Caretaker Unit
7274 Upper River Road
Pilkin County, Colorado
Job No. 12220
Ms. Schoeberlein,
As requested, we have evaluated the possible installation of a washer and dryer, to be placed in a
proposed caretaker unit on the subject property. We understand the caretaker unit will be using the
existing onsite wastewater system (OWS) installed in the early 1980's.
The existing OWS is 1 197 square feet (SF), and is a 'standard' drain field with 4" PVC pipe and gravel.
The existing OWS was excavated in April, 2000 in two locations and appeared to be functioning
properly.
The loading of a laundry washer is 19.5 gallons/per/day per person. A two-bedroom residence would
bring the loading to 78 gals/day, The existing OWS (tanks and drain field) can handle the additional
loading from a laundry washer place in the caretaker unit. We are only evaluating the addition of a
laundry washer.
Sincerely,
ClIURCH and Associates, Inc
Tim R. Petz, Project Manager
TRP
2 copies sent
copy to APEHD, Attn: Carla Block
DENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 80033
303.463.9317 Fax: 303.463.9321
CASTLE. ROCK 303.6604358
EVERGREEN 303.8161,155
LOVELAND 970.6632124
Tom Dunlop, 11:40 AM 03/30/2000 -0700, Janet Schoberlein Page 1 of 1
r i
X -Sender: tomd@comdev.ci.aspen.co.us
X -Mailer: QUALCOMM Windows Eudora Pro Version 4.2.0.58
Date: Thu, 30 Mar 2000 11:40:41-0700
To: Nancy MacKenzie < nancym@ci.aspen.co.us >,
Carla Block <carlabt@ci.aspen.co.us>
From: Tom Dunlop <tomd@ci.aspen.co.us>
Subject: Janet Schoberlein
Hi,
I just spoke to Janet Schoberlein 923-2801 who lives in the Woody Creek area.
She wants to replace her current 4 bedroom home with a new one. Her isds was installed around
1980, she is not sure exactly. I told her we might have a permit, but could not guarantee it. She
wanted to do a perc test before April 15th, but I told her we wanted to wait until after that date
because of cold nights and days that might effect the test results.
She is not sure if she needs a new system or not. Her old one has been working fine according to
her. She has pumped the tank regularly.
Janet will be calling one of you (probably Nancy) to search for her old permit.
FYI, TSD
Thomas S. Dunlop, Director
Aspen/Pitkin Environmental Health Dept.
130 S. Galena St.
Aspen, CO 81611
tomd@ci.aspen.co.us
970 920-5073 desk
970 920-5074 fax
Printed for Nancy MacKenzie.<nancym@ci.aspen.co.us> 03/30/2000
CHURCH & Associates, Inc.
ENGINEERS & GEOLOGISTS
August 17, 2000
Jan Schoeberlein
26054 Centennial Trail
Golden, CO 80401
Subject: Installation Observation, Proposed Schoeberlein Residence
7274 Upper River Road
Pitkin County, Colorado
Job No. 12220
Ms. Schoeberlein,
As requested, we observed the installation of the onsite wastewater system (OWS) for the subject site on
August 1, 2000. The system was designed under our Job No. 12220, dated April 24, 2000.
The system includes the installation of a 2000 -gallon, two-compartment, precast concrete septic tank with
an effluent filter on the outlet, followed by a 1000 -gallon single -compartment precast concrete septic tank
with a pump. Three chamber -trenches were installed, as indicated on Figure 1. Each trench had one row
of 12 chambers, for a total infiltrative area of 558 square feet (SF). An as -built drawing is included as
Figure 1.
The pump and effluent filter were in place and wired at the time of our visit. The installation foreman, Jinx
Stone, may activate pumping system at his discretion. The components of the OWS were installed in con-
formance with our plans and specifications.
If there are questions or if we may be of further service, please call.
Sincerely,
CHURCH and Associates,
Edward O. Church, P. I 3772
,
EOC/trp "'gvgi; Fly
2 copies sent
copy to APEHD, Attn: Nancy MacKenzie
copy to Aspen Digger, Attn: Jinx, 630 Stgne Load, Basalt, CO 81623
DENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 80033
CASTLE ROCK
303.660.4358
303.463.9317 Fax: 303.463.9321
EVERGREEN
303.816.1455
—7
T
LOVELAND
970.663.2124
a
0
1.8 ACRES
7274 UPPER RIVER ROAD
PITKIN COUNTY, COLORADO
558 SF OF INFILTRATIVE
3 GRAVELLESS BEDS
EACH BED - I ROW OF
AREA IN
0
DISTRIBUTION
BOX \
WELL
% 99
I
�` /
EXISTING DRAIN FIELD
ONE -2000 GALLON TWO-COMPARTMENT
PRECAST CONCRETE SEPTIC WITH AN
EFFLUENT FILTER ON THE OUTLET
FOLLOWED BY ONE 1000 -GALLON
y SINGLE -COMPARTMENT SEPTIC TANK
WITH A PUMP
**41,*>
\98 /
I
I
I
I
PROPOSED 4 -BEDROOM
RESIDENCE
IRRIGATION DITCHES ARE 50 FEET EXISTING /N/�
FROM THE DRAIN FIELD % 2 -BEDROOM CABIN
UTILIZE
EX
EXISTING ♦� °/rC
WELL IS 100 FEET FROM THE DRIAN FIELD AND / y
DRAIN FIELD % EXISTING
1250 GALLON
SEPTIC %
TANKS
*** OWS AS -BUILT DRAWING
SCALE
1"=50'
JOB NO. 12220 FIGURE 1
Ct RCH & Associates,
c.
ENGINEERS & GEOLOGISTS
b&y4 2Wff
Aspen Pitkin Environmental Health Department
Attn: Nancy MacKenzie
130 Galena Street
Aspen, CO 81611
Subject: Clarification Letter, Proposed Residence
7274 Upper River Road
Pitkin County, Colorado
Job No. 12220
Dear Ms. MacKenzie,
This letter is to clarify errors in our OWS design for the subject site, dated April 24, 2000. The
percolation rate for the proposed OWS is 7 minutes per inch (MPI). The area that is required for a drain
field with a percolation rate of 7 MPI, four bedrooms, and a total square footage (SF) of 3500 SF, is 741
SF. Using a 301/6 reduction, we proposed three rows of I 1 chambers, for a total of 511.5 SF. All other
recommendations in our OWS design should be followed.
If there are any questions or if we can be of further service, please call.
Sincerely,
CHURCH & Associates, Inc.
Tim R. Petz
I copies sent
fax copy to 303.526.5171, Attn: Jan
fax copy to 970.927.160$, Attn: Nancy
DENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 80033 CASTLE ROCK 303.660.4358
303.463.9317 Fax: 303.463.9321 EVERGREEN 303.816.1455
It
ASPENIPITKIN EARONMENTAL HEALTH DEPARTMENT
ISDS DESIGN CALCULATIONS
Owner's Name Parcel ID #
House Size (sq. ft.) (75 gpd, 100 gpd, or 130 gpd) 100
Number of Bedrooms in Main House
Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House
Number of Bedrooms in Detached Caretaker unit
Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit
(If the caretaker unit is ATTACHED, treat as if part of main house.)
Average Daily Waste Flow 800
State Review Required? no
Perc Rate (T)
Design Flow (Q) = # potential bedrooms X 2 people/bedroom X gpd X 1.75
Q= 1400
Absorption Area (=Q/5 X SQRT perc rate)
A = 740.81037 sq. ft. of absorption area required
48 gravelless chamber units without reduction
# of Perc Holes Required: 3
1 in every soil type? Spaced uniformly over proposed area?
A masmtm 30% reduction is allowed for use of deep gravel or gravelless chambered system,
only if the lot size and soil conditions are optimal.
If a reduction is being proposed, describe why lot size and soil conditions are optimal:
A = 518.5 with reduction
33 gravel ss chamber units with reduction
Type of system: []Absorption trenches []Absorption bed [] Gravelless chambers
[]Dry well []Seepage Pit []Other (type)
Minimum tank capacity 1750 gallons
SETBACK FROM WELL
# of feet = 132
SETBACK FROM POND, STREAM OR IRRIGATION DITCH
# of feet = 82
SETBACK FROM DRY GULCH
# of feet = 57
/ \ Printed on Recycled Paper
IV
ASPENIPTTKIN ENVIRONMENTAL HEALTH DEPAR• ENT
ISDS DESIGN CALCULATIONS
Owner's Name SCHO,Eal f t [ fl+l „ . „ , 'r Parcel ID #
House Size (sq. ft) 200016000` (75 gpd, 100 gpd, or 130 gpd) 100
Number of Bedrooms in Main House 1 4 V
Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House 0
Number of Bedrooms in Detached Caretaker unit 0
Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit 0
(If the caretaker unit is ATTACHED, treat as if part of main house.)
Average Daily Waste Flow 800
State Review Required? no
Perc Rate 7 (1)
Design Flow (Q) = # potential bedrooms X 2 people/ bedroom X gpd X 1.75
Q= 1400
Absorptior Area Q/5 X SQRT)
A = 741 sq. fl. of absorption area required
48 infiltrator units without reduction
A maximum 30% reduction is allowed for use of deep gravel or gravelless chambered system,
only if the lot size and son conditions are optimal.
If a reduction is being proposed, describe why lot size and soil conditions are optimal:
GOOD SOIL CONDITIONS, DOSING NARROW BEDS
A = \/519 sq.fL with reduction
33 infiltrator units with reduction
Type of system: UAbsorption trenches UAbsorption bed [x] Graveness chambers
HDry wen nSeepage Pit 00ther
Minimum tank capacity 1750 gallons
SETBACK FROM) ELL
# of feet = 132 REDUCTION PERMITS 100' SETBACK
SETBACK FROM POND, STREAM OR IRRIGATION DITCH
# of feet = , 82 REDUCTION PERMITS 50' SETBACK
SETBACK FROM DRY GULCH
# of feet = 57
FINAL INSPECTION BY: DATE:
0 0
Engineer's Submittal for Septic Permit in Pitkin County
Owner's Last Name: SCHOEBERLEIN Location: 7274 UPPER RIVER ROAD
Summary of information regarding new septic system:
Type of system being proposed: SEPTIC TANK AND GRAVELLESS CHAMBERS
Other treatment processes being used: NONE
Does the system use any mechanical parts? (Prohibited unless there is no alternative)YFS
If yes, explain why there are no alternatives A PUMP IS REQUIRED DUE TO ELEVATION
DIFFERENCE FROM SEPTIC TANKS TO DRAIN FIELD
Does the system require any maintenance other than routine pumping? YES
If yes, who will do the maintenance? CLEAN FILTER WHEN SEPTIC TANK IS PUMPED
Are any reductions being proposed? YES
If yes, what makes the lot and soil conditions optimal?
GOOD SOIL CONDITIONS AND DOSING TRENCHES
Which of the following are on the site or within setbacks?
Closest distance of septic system to each feature
Q 100 year floodplain
)
Q well(s)
>100 FEET
Q irrigation ditches
>50 FEET
Q streams
>50 FEET
Q ponds
Q other features
What was the profile hole depth? N/A
What is the depth to groundwater? NL
What is the depth to bedrock? N/A
What assumptions, if any, were made in system sizing and design? (Include any local, site-
specific data, such as months without snow cover, ratio of evaporation to absorption, etc. that are
relevant.) AN 8 FOOT TEST PIT IS REQUIRED PRIOR TO DRAIN FIELD INSTALLATION.
If there are any variations from normal design, please explain how they can be demonstrated to
improve treatment and protect water quality. NONE
JC)
Rpr 04 00 01:31p
William F
Schoeherlein
303-526-5171
•
fi'd 11f0►
.
i Pff[ON COUNTY
ARE-ArFUCATION CONFERENCE SUM?""
�
I� � � � P1ANN5R' Snenne-woltT DATE: lune 15, 1999
SMaeDeflem
PROJECT: dtpsimraQve 1041 kiara'd Rreview dt fiMQS Eta
IOCAT3@�f:.i7274Uppef RivwRcad
OWNER- I pho.dFar. (303152l.BSOSiS2(,5L7L QR 923-2801 (P4) I
Hari.d Revsen' d-GMQS fXcUlptim
dop twt Applicant propses todemohsh 00-e124iagss'410 and tephct d e
t�Mactrk semelauiauasticaristes�asidasm fnwdwww;cwwwdvwfm-improycmants,dle
Adiel! b a baildmR envelope uamd the arcading and. popotrd imPtWmtmAt. Tfw budding cuvd )Pc
silkseltb; y t041 d aet "MaPPd wiWlifiellabisal ffrsiss)a< Il lascaw Additional impaett ac, IC141 was
(low MUMASNICINut im p"mwd h she pevio.s> .di/Wsbed arta). 11t budding to be deonolubod is ler 100 y:an
old, but is noon pitltin Cornty Hivotic Lncw—y and a aeoosideted Cl4kk Gds the Stade dHissa is
ces
Pbr. f4lol 1 1
Land Use Cause Seotiaas{b addatsik bttw of sequsxtlappficatios:
I
Seet6634(X10 I Beard Review: TLe-ptoposedbuikUngmvdopedufl,itke+. avoid 1041 ha d:anroi 08 tot
cteato additional 1041 imp"M in order to be d*" fox she ad,miaiWative ¢view'.
----,"3.150- GHQS-E2emptm to Reple.'.e a L 01Y FsabliAW SMUCIOM In osde+ to be eligiale 1« th Is
tiem�tioq thcA licaet drR docm.snsl wbsys the tsr.ewreaas oowAnsHel sadtbat thetvre rasnplie w�1 the
"dwe j mit"=dd,,77tfia-tion in �e Godo "...a s"rwe4yenleraWe Fwma taubisapoa of rooms, whi contain
k;�nyc�bgtx batls hN'`inea asst whs6 tRdcsiFped for or an be 056M1asa resideocebY s single family orals,
'I� of `,,..j"', faesilieseegusests.- II
SnQwW mfelow Azoning, wood) Crw& Cautus
Yasiew by: V omm ity�oeat O recant _
S..a�—t�f+a wti
c Plsmiog Fcaj
To opply. tlre-fna"Aop iafoamati� utas voted 64ty—t: 1
II ;
1. falter of jxpjts4 CodeSecuous lived above;
2. 24" z 36`Site Plan - h mmpliacxmh the povisiwu of Sect' w 5--70.040 (anacb4 i
t
3- foasust floor owner( m ptoce>;l application and asabatixiyl the repfCSeNativc (if;piiraWe)(1 m0Y%
4. Pasml dnrtsp , udmg kgd d=QiPIR Ud ve[Indy MAP
S. Copy ctf t+rs;sn"M (I mPY) I
6. App !ot fro:
7. Pmofof
TAis preapplFratioa erny�mxe awunary it advtsary in natre and wl binding on dee Cowry The vlJor iar pre° dad
w dw satnaaiy is based canrem -mug simukrt6 and staff' 6nerpresubw s bused upon eeprescnsmion of the
of-
0
April 27. 2000
JANET K. $cHOEBERLEIN
26064 CENTENNIAL TRAIL
GOLDEN. OOLORADO 00401
1303) 52e-0606
Nancy Mackenzie
Aspen/Pitkin Environmental Health Department
130 S. Galena St.
Aspen, Colorado 81611
Re: Application for Building Permit
7274 Upper River Rd., Woody Creek 81656
Dear Nancy:
I am enclosing the following.
E
Application for Individual Sewage Disposal System
Exhibit A — legal description
Site map
House floor plans — 81 /2 a 11
Bacteriological test results for water supply from Aspen Consolidated San. Dist.
Report on Well Permit 7576 from Colo. Div. of Water Resources
Soil & Foundation investigation from Church & Associates
Engineer's Submittal for Septic Permit in Pitkin County
Check in the amount of $330 for Permit Fee
Copy of Pitkin Cty Pre -Application Conference Summary
Please let me know if you have any questions or require further information. Thank you for
your assistance.
Sincerely,
ganetK. Schoeberlein
970-923-2801
Encls.
,uY
• Exhibit A • i 9 uth,
_ and 15a Section 9, Townsh P
li tract of land situated in Lots l� Heridian, described as follo
the Sixth Prinetp line o a a'cEroadway
•43
Range 85 WQ5t Of i on the southwesterly
Beginning at a p° of said SeC.ion'9 bearer o 08+ W. 240.83 feet;
Vh¢nce the South l/4 7a7 feet; them the southwesterly line of
feet; thenar S+ E-33 0.00 feet, to i point 8 60 feet, along the s�ttaaining
thence S. 430 57 S. 490 58 E}}�e int of beginning.
w�e�Eine of d public road
walY to
1.75 acres 7ppYe oa less- those Prot4` i'*" restrictio2sand
0I
ressly made subJect to recorded at Book
ante is exp 116481,
eRantnseuhicn appear in full at Document No.
gage 362, of the Records of Pitkin CAuntY,
0 0
CHURCH & Associates, Inc.
ENGINEERS & GEOLOGISTS
April 24, 2000
Janet Schoeberlein
26054 Centennial Trail
Golden, Colorado 80401
Subject: Subsurface Investigation and OWS Design, Proposed Residence
7274 Upper River Road
Pitkin County, Colorado
Job No. 12220
Dear Ms. Schoeberlein,
As requested, we have investigated subsurface conditions at the site and designed an onsite wastewater
system (OWS) for the proposed residence. Subsurface conditions were investigated April 18, 2000. Our
firm conducted a Soil and Foundation Investigation for the subject site, and is presented under a separate
letter.
SITE CONDITIONS
The site is in a rural residential area of Pitkin County, Colorado in the Woody Creek area. There is an
existing 2- s, on the southern portion of the lot that is utilizing an 1197 square
feet (SF) drain field. Due to the bunk beds, we are designating the cabin as based on three bedrooms.
According to Pitkin County regulations a three-bedroom residence having less than 2000 SF and a percola-
tion rate of 8 minutes per inch (MPI), requires 446 SF of drain field. The existing drain field, as indicated
on Figure I is 1197 SF in area and appears to be functioning properly. The drain field is presently exposed
for county inspection. The existing tank configuration is sufficient to serve the existing 3 -bedroom resi-
dence. The proposed drain field area has relatively no slope and a moderate cover of native grasses.
PROPOSED CONSTRUCTION
A four-bedroom residence with living area of between 2000 and 6000 square feet (SF) is proposed at the
location presented on Figure 1. We have sized the OWS based on four -bedrooms and 800 gallons per day
(GPD) using Aspen/Pitkin Environmental Health Department (APEHD) loading of 100 gallons per day per
person. The sewage loading with a peaking factor of 1.75 is 1400 GPD. This loading includes washing
machines and a garbage grinder.
SUBSURFACE CONDITIONS
We performed a subsurface investigation by digging 4 percolation holes, 41 to 33 inches deep, and one
profile pit at the location indicated on Figure 1. Subsurface conditions in Profile 1 consist of 6 inches of a
sandy root zone; underlain to 2.5 feet by sandy, silty clay; underlain to the maximum depth explored of 8
feet by silty sand with gravel and -14%e cobbles. Percolation tests indicate percolation rates of 5 to 10 MPI.
The average percolation rate is 9,W. . Percolation data is presented in Table I .
J (� DENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 80033 CASTLE ROCK 303.660.4358
303.463.9317 Fax: 303.463.9321 EVERGREEN 303.816.1455
• Su fice Invesligalion and OWS Design
Job No. 12220
Page 2
RECOMMENDATIONS
The OWS includes one septic tank with a pump, and three chamber -type drain fields installed at the
locations presented on Figure 1. The OWS design is based on an average sewage load of 800 GPD and a
percolation rate of 8 MPI. We recommend the installation of one 2000 -gallon, two-compartment concrete
septic tank with a pump in a biotube vault, as indicated on Figure 3. A pump is required due to elevation
differences between the tank and the drain field. The air field requires the installation of three chamber -
type trenches, each trench having one row f i2 chambers. distribution box is required to control effluent
flow to the fields. We recommend a design ftow rate o -gallons per minute and a total dynamic head of
18.9 feet. Pump details are presented on the pump curve.
Based on subsurface conditions, topographic positioning of the well and irrigation ditches, and the casing of
the well, we believe setback distances can be reduced. The setback distance from the irrigation ditches and
the well can be reduced to 50 feet and 100 feet respectively. The resultant flow from the drain field will be
away from the well and the irrigation ditches and contamination of these by the OWS will be prevented.
An eight -foot test pit is required during "spring runoff' and prior to OWS installation to confirm
ground water and soil conditions. The county and our firm must be contacted to observe the test pit.
Movement over the drain field area during construction should be kept at a minimum to prevent
compaction of the receiving soils. We recommend the bottom of the bed be scarified with a pick,
shovel, or backhoe bucket teeth prior to the addition of chambers.
We recommend the surface of the fields be seeded after installation of the fields. We recommend using a
native seed mix available at seed stores. These mixes do not require irrigation and develop a growth 10 to
15 inches high. No automatic sprinkler system should be installed over the fields.
OPERATION AND MAINTENANCE
The owner must realize an OWS is different from public sewer service. The owner must be aware of
and assume responsibility for maintenance of the system. In the absence of a monitoring program, we
recommend the septic tank be pumped every two years. Effluent filter and screened vaults, as applic-
able, are to be cleaned during pumping. There are daily considerations such as not putting plastic or
other nonbiodegradable materials into the septic system. Garbage disposal use should be minimized.
The backwash of a water softener may be harmful to the OWS. A separate drywell should be constructed
for the backwash waste, if a softener is installed. Chemically treated water from a swimming pool or spas
should not be introduced to the OWS.
LIMITATIONS
A contractor who is experienced in OWS installation should install the OWS design. Our investigation,
layout, design and recommendations are based on data submitted. If subsurface conditions considerably
different from those described in this report are encountered, we should be notified to evaluate the effect on
the proposed OWS. If the health department makes modifications to this design, we should be contacted to
evaluate the impact on the performance of the OWS. The county and our firm must be contacted upon
completion of the OWS
17
• Subace Investigation and OWS Design
Job No. 12220
Page 3
All construction is to be in accordance with the ISDS regulations. Pipe type and size, burial requirements,
septic tank construction, and other specifications, which are not depicted in our report, are to conform to
the requirements of the ISDS regulations. The installer of the system is to have demonstrated knowledge of
the APEHD ISDS regulations and requirements.
If there are any questions or if we can be of further service, please call. The project manager for this site is
Tim Petz.
CHURCF
Edward C
EOC/trp
3 copies sent
I'k
0
1.8 ACRES
7274 UPPER RIVER ROAD
prMN COUNTY, COLORADO
558 SF OF INFILTRATIVE
3 GRAVELLESS BEDS
EACH BED - I ROW OF 12
AREA IN
CHAME
0
/• P-1
lop
\j moi. P-3
-ti
DISTRIBUTION
BOX
WELL
♦ ee
I
TWO 1250 -GALLON EXISTING
SEPTIC TANKS FOLLOWED BY 1197
SF OF DRAIN FIELD
ONE -2000 GALLON TWO-COMPARTMENT
PRECAST CONCRETE SEPTIC TANK
' so -,--WITH PUMP IN BIOTUBE VAULT
Asa 4*
I
I
I
I
PROPOSED 4 -BEDROOM
RESIDENCE
IRRIGATION DITCHES MUST BE 50 FEET ` EXISTING
FROM THE PROPOSED DRAIN FIELD OR THEY ♦ 2 -BEDROOM CABIN / 4Ti� O
MUST BE LINED OR CULVERTED ♦` TO UTILIZE
EXISTING I� VACy
WELL MUST BE 100 FEET FROM THE DRIAN FIELD AND /
PROPOSED DRAIN FIELD ♦ EXISTING
♦ 1250 GALLON
SEPTIC
TANKS
♦♦ �e SITE PLAN, LOCATION OF
PERCOLATION HOLES, AND
LOCATION OF PROPOSED OWS
JOB NO. 12220
SCALE
1"=50'
FIGURE 1
•
TYPICAL PLAN VIEW - N.T.S.
4" SDR 35 PERFORATED PVC PIPE
PLACED ON GROUND ACCORDING
TO MANUFACTURERS SPECIFICATIONS
C
3'
4" SDR 35 PVC
OBSERVATION/VENT PIPE
TYPICAL CROSS-SECTION - N.T.S.
3'
4" SDR 35 PERFORATED PVC PIPE
PLACED ON GROUND ACCORDING
TO MANUFACTURERS SPECIFICATIONS
0
4" SDR 35 PVC
OBSERVATION/VENT PIPE
WITH CAP
LL EXTENT OF EXCAVATION
EFFLUENT INLET _
(1/8" PER FOOT DROP)
GRAVELLESS CHAMBER
3' BY 6.25'
TOTAL - THREE TRENCHES
SLOPE F -
MIN. OR DRAINAGE `'
1.5' MIN
GRAVELLESS CHAMBER
3' BY 6.25'
CALCULATIONS AND SPECIFICATIONS
DESIGN CRITERIA
RESIDENCE — 4 BEDROOMS, 2000-6000 SF
LOADING — 100 GAL/DAY/PERSON
TOTAL LOADING — B00 GPD
PERCOLATION TEST — 7 MPI
AREA — (1.75 X Q XRT)/5
AREA — 792 SF hyo
REDUCTION FOR USE OF CHAMBERS — 30%
TOTAL AREA — 555 SF 5iy
LEVEL MANIFOLD
STRIBUT10N BOX
EFFLUENT LINE
TO THIRD TRENCH
TYPICAL DISTRIBUTION BOX - N.T.S.
TRENCH SPECIFICATIONS
NUMBER OF TRENCHES — 3
LENGTH OF EACH TRENCH — 75 FEET, 12 CHAMBERS
WIDTH OF EACH BED — 3 FEET, 1 CHAMBERS
TOTAL NUMBER OF CHAMBERS — 36 CHAMBERS
TOTAL AREA — 558 SF
DRAIN FIELD DETAILS
l
3' APPROX.
PLAN
VIEW
Im I
CONCRETE DISTRIBUTION
BOX
�,__4" SDR 35
PVC PIPE
ONLET
INLET OUTLET
VIEW VIEW
• MINIMUM OF FOUR OUTLETS NEEDED
OUTLET
TOTAL CAPACITY — 1.75 X 0 X (30 HOURS/24 HOURS) _
1750 GALLONS
RECOMMENDATION — ONE 2000 GALLON TWO COMPARTMENT
PRE—CAST CONCRETE SEPTIC TANKS WITH A PUMP IN A
BIOTUBE VAULT
FIGUR
" TO 8"
1.5' A
PROX.
1' APPROX.
INLET OUTLET
VIEW VIEW
• MINIMUM OF FOUR OUTLETS NEEDED
OUTLET
TOTAL CAPACITY — 1.75 X 0 X (30 HOURS/24 HOURS) _
1750 GALLONS
RECOMMENDATION — ONE 2000 GALLON TWO COMPARTMENT
PRE—CAST CONCRETE SEPTIC TANKS WITH A PUMP IN A
BIOTUBE VAULT
FIGUR
40M1..i
CHURCH & ASSOCIATES, INC.
Effluent Pumping System
Orenoo Systems*
20004ALLON TWO COMPARTMENT PRECAST CONCRETE SEPTIC TANK WITH A PUMP IN A BIOTUBE VAULT l" rponftd
Fibarrggloo Gosketed Lid with
Stainton Steel Bolts
Slope Ground
Away from Meer
Inlet Tee
Conduit Seal
Conduit to—
Height Varies
18' Winimum
Disclosure. The owners of Church & Associates, Inc. also own S.C.G.
Erderprisee, Inc, which distributes Orenco Systeme Inc. products
Patents 14,439,323 i 5,492,835
Foreign Patents Pending
G 1997, Orenca Systems, Inc.
Job No. 12220
SEK PVC PVC Riser with Grommet(s)
ice Box (bond to tank adopter with
recommended odhol e)
WC Splice Box with Cord Gripe
f. Discharge Assembly
Fkodble Hose
Effluent Discharge
Tank Adapter (cost or bolted)
c Hann 6 _1—.j r,..a..0 FI„M
On/Off Redundant Off W/Alarm
Check Valve (optional)
Voult Inlet Porta
1/8' Weep Flow Inducer
Hole Effluent Pump
Filter Cartridge
Drain Port
Effotubedl Pump Voult
EDW—TD-3
Rev. 1.0 (2/98)
FIGURE 3
•
•
0 0
0
N
m
U
U C
C �
%J'
g
N
O
O
11loll
O
II11111I
O
~
Q
=I;11
11
N
>
@
W
N
III
N
LL
Ism
U
y N
d
111
loll
W
Z
o
loll
Hill
0
LL
01
0«
O
M
3
L
co
J
m
o
v
W
Q
=
S
H
N
61
y
x
O
0
q
�...
1�.��..�.111
m
=
:1
,.
.mi 1.9.I
IN
1111 ■ 1
long
11111
111■■■■■
.■. ll
op
11
.�I•.■loll
R.9
.■.ri.i■.■■
1 o
■■I
Isom
11111
Ism 1199
io:.il.:
■1=1111..■
...■■.■■■
sling
on
1■1../I
�..:':.11i111i
■.1
- ■►,.
py
- still
■o1%.1
- oulm■ol■■■
.II.■l..m■....1■..
Woollom
111.
1 ■■.■llCllll�
•
11011
on
looms
111
►■;
1.:.
■.1
►�■.losing
l
01■
■i/■
.
llllll■:ll:1111■
■■l
.loll.
- I�..
_ ...
.=
�........■lOil
;.
�■n
loll
;..
_
r""'
iemongolil.■■l:INN
on
I 1
1:-
0
N
m
U
U C
C �
%J'
g
N
O
O
O
O�
O
~
Q
LD
N
>
@
W
N
C
N
LL
o g
WQJ 1H41] WOH C�I�0 RPI
u
o o b o m
n o o Lo@ m
N
O til O O
0
h
0
m jE
M
a
�Z
E
~
Q
w d
d
>
rG
W
CL
LL
3
U
y N
d
W
Z
o
N Z
0
LL
01
0«
O
M
3
L
co
J
m
o
v
W
Q
=
S
H
N
61
y
x
O
0
q
m
=
x
0
h
0
m jE
M
a
�Z
E
Profile:
TAE 1 - PERCOLATION TEST RESTS
7274 UPPER RIVER ROAD DATE OF TEST: 4/18/00
PITKIN COUNTY, COLORADO
feral rincerintinn
o- 1' (OPSOIL, SANDY, SILTY, ROOT ZONE
V- 2.5' CLAY, SANDY, SILTY, STIFF. MOIST, RED/BROWN
2 5'- 8' SAND WITH GRAVEL AND GOBBLE, SILTY, DENSE, MOIS I RED
NO BEDROCK OR GROUNDWATER PRESENT
HOLE DEPTH TIME
NUMBER OF HOLE, INTERVAL
(INCHES) (MINUTES)
AVG
DEPTH DEPTH CHANGE, INTERVAL HOLE
START, END, (INCHES) PERC PERC.
(INCHES) (INCHES) RATE (MPI) RATE,
IMPII
2
35
10
350
600
2.50
4
10 1 00 250 1 50
7
10
150
262
1.12
9
10 1 25 250 1.25
10
262
462
2.00
5
8
10
125
275
1.50
7
10
275
425
1.50
7
10
125
275
1 50
7
7
3
33
10 4.50 5.50 1.00
10
10 1 00 250 1 50
7
10 4.25 6.00 1.75
6
10 1 25 250 1.25
8
10 2.50 375 1,25
8
10 175 300 1 25
8
8
NUMBER OF HOLES: 4
AVG PERCOLATION RATE (MPI): 7
Joh No. 12220
Profile:
TARE 1 - PERCOLATION TEST RESTS
7274 UPPER RIVER ROAD DATE OF TEST: 4/18/00
PITKIN COUNTY, COLORADO
faaf dasrrinfinn
0- 1' TOPSOIL, SANDY, SILTY, ROOT ZONE
1'- 2 5' CLAY, SANDY, SILTY, STIFF. MOIST, RED16ROWN
2 5'- B' SAND WITH GRAVEL AND COBBLE, SILTY, DENSE. MOIST RED
NO BEDROCK OR GROUNDWATER PRESEN T
NUMBER OF HOLES: 4
AVG PERCOLATION RATE (MPI): 7
Job No. 12220
AVG.
HOLE DEPTH TIME DEPTH DEPTH CHANGE, INTERVAL
HOLE
OF HOLE, INTERVAL START, END, PERC
PERC.
NUMBER (INCHES)
(INCHES) (MINUTES) (INCHES) (INCHES) RATE (MPI)
RATE,
(MPII
NUMBER OF HOLES: 4
AVG PERCOLATION RATE (MPI): 7
Job No. 12220
0 0
CHURCH & Associates, Inc.
ENGINEERS & GEOLOGISTS
March 10, 2000
Janet Schoeberlien
26054 Centennial Trail
Golden, Colorado 80401
Subject: Soil and Foundation Investigation, Proposed Residence
7274 Upper River Road
Pitkin County, Colorado
Job No. 12220
Dear Ms. Schoeberlien,
As requested, we investigated subsurface conditions utilizing test pits dug at the subject property on
February 22, 2000. The purpose of our investigation was to evaluate subsurface conditions at the bearing
level of the proposed residence.
The site is a 1.75 -acre parcel located in a rural -residential area in Woody Creek, Colorado. There is an
existing residence with a partial basement in the location of the proposed residence that will be demolished
prior to new construction. The proposed residence will be a 2 -story structure with a full basement and
wood frame construction. Relatively light loads are anticipated.
Two test pits were excavated using a rubber tire backhoe, as indicated on Figure 1. Subsurface conditions
in Test Pit 1 (TP -1) consisted of 6 inches of topsoil, underlain by very silty clay to 4 feet, underlain by sand
with cobbles and gravel to the maximum depth explored of 9.5 feet. Subsurface conditions in TP -2
consisted of 6 inches of topsoil, underlain by very silty clay to 4 feet, underlain by sand with cobbles and
gravel to the maximum depth explored of 8 feet.
The results of laboratory testing are attached as Figures 2 through 4. The hand drive taken from TP -2 was a
sample of silty clay and exhibited a 2.6% consolidation wetted under a surcharge pressure of 1000 Pounds
Per Square Foot (PSF). The hand drive taken from TP -1 had a moisture content of 4.01/o. A bulk sample
was taken from TP -1 at 8 feet and had a fines content of 14 percent.
The results of our observations and laboratory testing indicate a spread footing foundation system is
appropriate. Spread footing supported by sand and cobbles should be designed for a maximum allowable
bearing pressure of 2500 PSF. Footings should bear on the native undisturbed sand and cobble, beneath the
silty clay zone, at minimum depths of 4 feet. Areas in which material is disturbed or where existing
foundations have been placed, must be excavated to native soils. The sand and cobble have nil expansion
potential. We believe four feet of frost protection is necessary. We recommend an exterior foundation drain
be installed around the basement foundation to discharge into a sump pit or to be daylighted away from the
residence. A detail of the subsurface drain is presented on Figure 5.
.DENVER 4501 Wadsworth Boulevard Wheat Rldge, CO 80033 CASTLE ROCK 303.660.4358
. c _ 303.463.9317 Fax: 303.463.9321 EVERGREEN 303.816.1455
Soil and foundation Invcsligation
• • Job No. 12220
Page 2
Any soil loosened or disturbed during foundation construction should be removed prior to placing concrete.
Excessive wetting or drying of the subgrade should be avoided during construction.
We appreciate the opportunity to be of service on this project. If there are any questions or if we can be of
further service, please call.
Sincerely,
Pip REGI
CHURCH & As
�e'4r�O.Cy T
G9�
v •o
13 7 s
Edward 0. Churc
•-. I3- (U_
ss/ONAL EN
EOC/trp
3 copies sent
fax copy to 303.526.517 1, Attn: Janet
727.4 UPPER RIVER ROAD
PITKIN COUNTY, COLORAW
0
-- -- -- -- --
EXISTING CABIN
I1
' EXISTING RESIDENCE '
TO BE REMOVED
20'
TP -1
TP -2 '
rn in
UPPER RIVER ROAD
SITE PLAN AND LOCATION
OF EXPLORATORY PITS
JOB NO. 12220
NOT TO
SCALE
FIGURE 1
10
,3.{SI-Lk - ig1
ROOTZONE, SANDY, SLIGHTLY SAND WITH COBBLES AND GRAVEL, DENSE TO
® MOIST, DARK BROWN/RED VERY DENSE, MOIST, RED/BROWN/UGHT
BROWN
CLAY, VERY SILTY, SANDY, MEDIUM STIFF,
MOIST, RED/BROWN
NOTES:
WC = MOISTURE CONTENT %
DD = DRY DENSITY
-200 = PERCENT PASSING THE -200 SIEVE
I DEPTH AT WHICH SAMPLE WAS TAKEN
TEST PITS WERE EXCAVATED WITH A RUBBER TIRE BACKHOE ON FEBRUARY 22, 2000
LOGS OF TEST PITS
JOB NO. 12220
D�
FIGURE 2
TP -1
TP
-2
oll
HAND DRIVE
WC = 4
HAND DRIVE
-200 = 59
WC = 11.4
06
00DD = 99
o°
00 -200 = 59
o°
o°
o,
BULK
-200 = 14
10
,3.{SI-Lk - ig1
ROOTZONE, SANDY, SLIGHTLY SAND WITH COBBLES AND GRAVEL, DENSE TO
® MOIST, DARK BROWN/RED VERY DENSE, MOIST, RED/BROWN/UGHT
BROWN
CLAY, VERY SILTY, SANDY, MEDIUM STIFF,
MOIST, RED/BROWN
NOTES:
WC = MOISTURE CONTENT %
DD = DRY DENSITY
-200 = PERCENT PASSING THE -200 SIEVE
I DEPTH AT WHICH SAMPLE WAS TAKEN
TEST PITS WERE EXCAVATED WITH A RUBBER TIRE BACKHOE ON FEBRUARY 22, 2000
LOGS OF TEST PITS
JOB NO. 12220
D�
FIGURE 2
3q
0
CHURCH & Associates, Inc.
Engineers & Geologists
Denier Colorado, 303463-9317
rvutpeeu Colemdo, 303-916-1455
Castle Rwk, Coluntdo 303-6604358
Gradation Test Results
a200 #100 450 a30 a16 48 a4
0
3B' 3u' 1-12' 3'
0.01 01 1 10
Dh melee of Particle hi Ml6imetem
DESCRIPTION: Sand with Cobbles and Gravel
0
00
100
GRAVEL 21% HOLE / SAMPLE
TP -I @ 8'
SAND 65% DEPTH
FINES 14% LIQUID LIMIT
N/A
PLASTICITY INDEX
N/A
DRY DENSITY (pet)
N/A
i
�inH
vii
i
u
I►
iii
IIl
.���ini�
i�Nl
l
ildilli
m
�l
111111111,
MIN
1
0.01 01 1 10
Dh melee of Particle hi Ml6imetem
DESCRIPTION: Sand with Cobbles and Gravel
0
00
100
GRAVEL 21% HOLE / SAMPLE
TP -I @ 8'
SAND 65% DEPTH
FINES 14% LIQUID LIMIT
N/A
PLASTICITY INDEX
N/A
DRY DENSITY (pet)
N/A
DATE: 3/10/00
JOB NAME: Schoeberlien
JOB NUMBER: 12220
FIGURE 3
s
7
6
5
5)
-6
-q
0 0
CONSOLIDATION UNDER CONSTANT
PRESSURE DUE TO WETTING
1 10
APPLIED PRESSURE - ksf
Sample of SILTY CLAY, TP -2 @ 3 FEET
Natural Dry Unit Weight =11.4 %
Natural Moisture Content = 99 PCF
100
JOB NO. 12220 SWELL - CONSOLIDATION TEST RESULTS FIGURE 4
�_�
BACKFILL
M IRAFI 140N
OR EQUIVALENT
GRAVEL: MINIMUM GEOTEXTILE FABRIC
I CUBIC FOOT OF
GRAVEL PER LINEA
FOOT OF DRAT
----a • 0 O O
D0 0.0;x. °0
• a O •4• U 0:'%
O yi
� o 0006
O Q �
0 i
6" MIN ..o• a Q 0C.O Qo. o
h 00—$
❑4 0
12 MIN. ,o•op:; •
INSTALL DRAIN 1
ABOVE LINE
JOB NO. 12220
J
NOTES:
GRAVEL SPECIFICATIONS:
CLEAN WASHED GRAVEL 100%
PASSING 1.5' 60-100% RETAINED
#4 MAXIMUM 3% PASSING #200
POLYETHYLENE SHEETING
•1•
>PERFORATED
4 INCH DIAMETER
PVC
MIN. PIPE SLOPE OF 1/8'
PER FT FOR SOLID
PIPE AND 1/4' PER FT
FOR FLEXIBLE PIPE
I. DRAIN PIPE SHOULD LEAD TO SUMP OR POSITIVE
GRAVITY DISCHARGE.
2. WRAP GRAVEL COMPLETELY IN AREAS OF SANDY
OR SILTY SOILS.
3. DRAIN SHOULD BE A MINIMUM OF 12 INCHES BELOW
SLAB AT HIGH POINT.
12 MIN.
TYPICAL EXTERIOR BASEMENT WALL DRAIN
FIGURE 5
to 0
}
f) C 3 8Ol
3 i G
5�
e
a 12.50 CALL vi T, (-o CcH:DqeTmr yr
I+f ����CP CDh'tfi£ 7Trc Tl,r1:G
U/fThl %-' R1$E,Q,� Qy lviflN}IO(�S
DM
se�rr� K wiry &Vf— 8
�N N�oc_E
ABA IJ F `'
14ETAL T/W k'
�V,r„�-��^e:ftonK-QI
Igo -k: �q�� /I �(
s e co p. Taav� —t vi y
i �{.le+&'. 118Y, $ f'
1
i
� CAbd
L�-WELL
Sent By: ACSD Wastewater Facility; 9709257278
�1 �
i Apr -27.00 12:18; Page 212
STANDARD BACTERIOLOGICAL WATER TEST
ASREIL C0119OLIDATED SAXIMArm MSTRICT
Oft SERIAM CENTER DRIVE
AWM COLORADO 11111
SAANETAREM. DATE tTAi 7!2.'lA/jJ
1 ) COMMUNITYSIwRY ( 1YSTTA &Mty
I I NCNCOWAWTY ( I CHECK � j I ) PROCESS WATER
1 ) OTHER P°9LC ( 1 HAW I ( ) SURFACE
( J,ir(eL'ATE ( I SREpAL NM'LC
8"MOTALL WWMTM KIDT LN/nRiF
MTHIMAIYIE WILL IN! N7CAAawRETLM To
REVARK
FECAL ABSENT PRESENT
ZI
- SEE votx-TIDIM OR 8ACR PAQE - RF9IATS WDN 0 E 0R vAw cDUFOLi15
WMREVOW FOR TIEL TIONS, SAWLiND IN5TRUDTIDN$AIID DETHATIDNS PERIOD ML MICATE NON.00MPLWXE
WRHMNAR) DRVVMwATERSTMgARD5.
FOR TEST
g Al
as
RPR -26-2000 15:59
REPORT DATE
Wad Apr 26 15:29:46 MDT 2000
r Receipt 9116835
Permit 7576
Div 5 Wd
Basin Md
Engineer User
RUSSELL WILLIAM
Address
Proposed 0
0
Actual 30.00
WOCREEK
Telephone
acres
Case
Permit XRef
0
Well Name
County
PITKIN
010
040
NW
0160
SW
Sec
9
Ts
9 South
Rng
85 West
Pm
Sixth
38
0
State
Co
DIV 5 WTR RESOURCES
OLORADO WELL APPLICA l IONS
OLORADO DIVISION OF WATER
zip
81656
Subdivision Filing Block Lot
Parcel Size PIN
0
Main AcOVnY
Interim Status
Last Action
Permit Issued
Permit Expires
Expire Notice Sent
Well Const Report
Well Const Complete
Well Report (Non Crib)
Pump Install Report
Pump Install Complete
1st Beneficial Use 12-04-1960
Statement Benef Use
Benef Use (Non -crib)
Abandonment Report
Well Plugged
DOMESTIC
1 -AjJ ttlo ] 1� r. Gc�ew
V I'hRMIIS
Pump Rate
Ann Amt
Proposed 0
0
Actual 30.00
0
Irrigated Area 0
acres
Elevation 0
Pert Casing Top 0
Perf Casing Bottom 0
Water Level 57
Aquiferl
Aquifer2
Driller
Pump Installer
Statute Meter Log
Dual AbReq
No No
No No
Comment
Depth
0
76
APR -26-2000 15:59
DIV 5 WTR RESOURCES
1 30S Ebb 5415 r.W/04
form
.No.
taw$ -t t
4M9
STATE OF COL
OFFICE OF THE STA GItffER
818 Centennial Bldg„ t"13 SL, Denver, CO 80203
(303) 886-3581 Fax (303) 8811-31M
For Omte Only
i
CHANGE IN OWNERSHIP/ADDRESS
CORRECTION OF THE WELL LOCATION
`
j
Insert the Well Permit Number %'5-,76
and welt
NAME(S) �7 ! e�//\�. ScC- 1 d Q V,
If your well has an absolute weer riaM decreed
well
by the court and thewwell iss not registered with the �
////4
Mailing Addresses 6 ( � ? I7 / 4..t2 �rQ i J
�O ,�_
//
CRY, SL Zip /qy n n s > 0 �V�
Some Ertweheer. Enter the WaterCoon Cate
Number / Civil Action Number and well number
as decreed.
Phone D O -75'-
This
This form is filed by the named indiuidwYenBty claiming that they are the owner of the well Pertmhed as relemnoed above.
This MM is made pursuant to C.R.S. 37480.143.
1
WELL LOCATION: t;,wrnty // YL Owner's 1Mell Designation
e—/6S6i
) V pp)
/(Addy I(S�tate) /
. or U , Range 0 E. or L� V11., (O "' P.M. I
I W 114 of theEVIM, Sec. Twp. �D NS.
Distance from Section Lines FL From O N. or S., FL From 0 E. or 0 W. Line I
Subdivision Name `Lo- caii- Lot . Block FilromAinit
The above listed owner(s) say(s) that he, she (they) own the well described herein. The existing record is being
i amended for the following reasons. L thange in name of owner ❑ Change 4h mailing address j
jO Correction of location for exempt wets permitted prior to May 8, 1972 and nonexempt wells permitted after I
May 17. 1M. Please see the reverse side for fulfner htfonnation regardmmg correction of the well location,
I (we) claim and say that I (we) (are) the owner(s) of the well described above aro that the conlmenoamenl of
extraction of ground water from tris well W&*My made under the well permit, occurred on the date indicated. and
OW the statements trade herein are true to my (our) knowledge.
print the Swow
p Name a Title
Sin (s) or Me newer. I Dab
ft o Uro responsb,My ofthe new owns mf to wN b cwriplsla and syn the tomb. siynatum d agents are gocq We if an I
origkW %Nm of aperay signal by the ower s atached to the form upon its receipt.
rorotsoeueohr
Sone blot:
JO
0
LEGEND & NOTES
FOUND SURVEY MONUMENT REBAR WITH CAP AS NOTED
O FOUND AL. CAP FOR THE SOUTH 1/4 SECTION 9 'LS 15710'
BOOK 746 PAGE 202 WAS THE ONLY RECORD INFORMATION
FURNISHED TO THE SURVEYOR. NO TITLE SEARCH WAS DONE
BASIS OF BEARINGS 1/4 COR TO FOUND REBAR AS SHOWN
IRRIGATION DITCH
-
WIRE FENCE
OVERHEAD ELECTRIC LINES
,o TELEPHONE / POWER POLE
$ WOOD FENCE
ELEVATION DATUM IS ARBITRARY BASED ON T.B.M. - 100.0'
SET STEEL SPIKE AS SHOWN, CONTOUR INTERVAL IS ! FOOT
gg 6 SPOT ELEVATION
LEGAL DESCRIPTION
A TRACT OF LAND SITUATED IN LOTS 13 AND 15, SECTION 9. TOWNSHIP 9 SOUTH.
RANGE 85 WEST OF THE SIXTH PRINCIPAL MERIDIAN. DESCRIBED AS FOLLOWS:
BEGINNING AT A POINT ON THE SOUTHWESTERLY LINE OF A PUBLIC ROADWAY
WHENCE THE SOUTH 1/4 CORNER OF SAID SECTION 9. BEARS 5.40.48'E. 1.636.43
FEET: THENCE S. 42.31'W. 367.27 FEET: THENCE N. 36.08' W. 240.83 FEET
THENCE N. 43.57'E. 310.00 FEET. TO A POINT ON THE SOUTHWESTERLY LINE OF
SAID PUBLIC ROADWAY: THENCE S. 49.58'E. 228.60 FEET, ALONG THE SOUTHWESTERLY
LINE OF SAID PUBLIC ROADWAY TO THE POINT OF BEGINNING CONTAINING 1.75 ACRES
MORE OR LESS.
COUNTY OF PITKIN
STATE OF COLORADO
CERTIFICATION
I. DAVID W. McBRIDE. A REGISTERED LAND SURVEYOR IN THE STATE
OF COLORADO. HEREBY CERTIFY THAT THIS PLAT WAS PREPARED FROM
A FIELD SURVEY PREFORMED UNDER MY SUPERVISION IN JUTA EX .
199- AND IS TRUE AND CORRECT TO THE BEST 0 DGE AND
BELIEF. THIS CERTIFICATION IS VOID UNLWEY�rl,,, ON AN
ORIGINAL BLUEPRWW.T. o'GlSlcp'•op'G
SIGNED TH1S ?L DAY OF I
16129
[, • yaRwlm ltmw �Mff
ACCORDING TO COLORADO LAW YOU MUST COMMENCE ANY LEGAL ACTION'
BASED UPON ANY DEFECT IN THIS PLAT WITHIN THREE YEARS AFTER YOU
FIRST DISCOVERED SUCH DEFECT. IN NO EVENT. MAY ANY ACTION BASED
UPON ANY DEFECT IN THIS PLAT BE COMMENCED MORE THAN TEN YEARS
FROM THE DATE OF THE CERTIFICATION SHOWN HEREON.
SCALE
I INCH - 20 FEET
30 40
1/4 CORNER
ON 9
CAP '15710-
SITE/TOPOGRAPHIC
SURVEY
SCHOEBER LEIN
TRACT OF LAND IN SECTION 9.
TOWNSHIP 9 SOUTH. RANGE 85
WEST 6th P.M.. PITKIN COUNTY.
COLORADO
PREPARED BY
ASPEN SURVEY ENGINEERS
210 S. GALENA STREET
P.O. BOX 2506
ASPEN. COLO. 81611
PHONE/FAX (970) 925-3816
JOB NO 231048
INC.
PROPOSED HOUSE ADDED 3-20-00
JUNE 22, 1999