Loading...
HomeMy WebLinkAboutpitkin.eh.264316101008 (1990)(From Most Recent to Oldest Permit) Permit Application Log Sheet/Notes & Photos Communications As -built Design Engineer Design Soil Information Water Permit & Information Second System on property Third System .etc. Floor Plans Please See Building and Land Use Approvals Files for additional information. 0 ASPEN*PITKIN 23-16/-0/-008 E IVIRONMENTAL FIEALTH OEPARTM.ENT. INDIVIDUAL SEWAGE DISPOSAL PERMIT NO.90�_ TYPE OF PERMIT: ( )Initial Construction ( )Emergency Use ( )Repair Work,(Piovicus Permit 1_.) Alteration of an exlpeing system, or installation(Previous Permit 1 q/0NE .) ( )Use Permit as a result of Sale ( )Others n C�/� ISSUED TO: DATE OF ISSUE, I 9 A Owner /v1A2k 91 KEit y f U.PWEl1 Home Phone q;_6 Business Phone Mailing i - - /� _ ��/� P// i Agent) Mailing Address Sewage Disposal System Work to be performed by &-0-F-SMq,,J - 6CX&1 Z - This permit valid only for premises location by the following 1 gal desert tions T%G� (E S LOT SIZE • y Aag&{ s NATER SUPPLY EL(.. S AVERA.CC PERCOLATION RATE Q//� - This Individual Sewage Disposal Permit is granted with regard to the following uset SIA --66- LJrS/�fNCt- Ntraber oft Dodreoms -IfL Lofts - Garbage Disposals_ Dishwashers_ Clothes Washers CALCULATED AVERAGE DAILY WASTE LOAD -7-50 GALLONS. THE NATURE OF THE SYSTEM INCLUDED UNDER THIS PERMIT: Typo . of Tank or Tres tment Unil:15 ./' a Tank Capacity !�-� t=l _Callon Nimmons �A16/AJEF� r,ithod of Final Disposals ED �. Square Feat Nintn.auAbsorptio0 Area t pQ Description (including brand name. if any) of other equlpment or appurtnanccat BED /N MOII O W 7N (N ISR 0- /000 CON�',F' T� 17QS/NG if1NC of /990 9. Fr /et" AVA110WdH SL- . J�LN/f'EUe- C - p Eii//VSTf!/.GEO PLf1A,tS DATeQ -a' �,EYE�G G.'eE2$ Other Conditions or E celficationar x-0(3 z!S --&M4 F&M /i0,T-qd"7- .LOT -51- 101eOAE 77 00JA1E1e-- /N0/e47infG' 1160ayT/oA) tdA7C,e FSM CXeXV,47-FD GICOdNDcuKTEiQ PI / 6AILy. STAGES REQUIRING INSPECTION BY THE HEALTH DEPARTMENT: ,/ ( )Before Excavation Upon completion of excavation and prior to p1see"ent of gravel yp Before covering distribution ,,1 //�'` n - 'lrystem of absorption field N�Prior to backfill of any component Other, Specify. rL-; ,- QA D i#Jtm Plans and apeciflcattons of the proposed sewage disposal system have been reviewed and are considered satlefaetory. Pe rnlsaloo is hereby granted to tl,P owner or his agent to Perform the work indicated above in accordance with the Pitkin County individual Sew y) Dispesal Rc•u:la eons in et fact on Una dile of issue. In addition to general provisions act fortb on the raveree hcraet, this Permit is subject to the following additional terms and conditions: Aspen/Pitkin Enviromtental APPROVED FOR ISSUE BY4 -Z (title) Health Officer The aLsve lr..tividual ac.eige disposal system Installed by &U I �MAAI - 6f7-9MZ . a iwcn (a.. �ic.l wr r.puvcn!..r sec ..( t:.^ ..... ..w _- �... •:� i—Tc=. p.0 t� :... .... _- h•::;wntiLllt!y Ing�sy a efnu lailurc or load yuauy of ttvlJC�11C d1]poa.11•3 y,tem. Compl,Ln as -Luis: !,-,In') etta Chnd. *- A' ;IAf. /nlsfr'cTioA/ RZ-1UJeD AV le" eW DATE OF Ili:; I, -r t i Aspen/Pitkin Environmental TITLE - Health Officer- - -- I ..\ 1 e/ 130 South Galens Street Aspen, Colorado 811G11 303/1320-6070 • ASPEN&PITKIN • ENVIRONMENTAL HEALTH OEPAMTMENT APPLICATION FOR AN INDIVIDUAL SEWAGE DISPOSAL- PERMIT Name of OWNER i PHONE 9 n 01 S Z� Address of OWNER .IID Li l f/T_- !C -x to Name of APPLICANT <Z�M Ae PHONE 9a S S z 3 PERMIT TO BE: Picked Up ( )Nailed to: TYPE OF REKNIT: VfNew Installation ( )Repair ( towner ( )Applicant ( )Emergency Use ejAilteratio. NOT due to failure ll _•ATION OF PROPOSED SYSTEM. _ _�j, / flee ,� 6 ?'� X4 S Legal Description /GJ Lot Block Filing Subdivision Site of Lot scree TYPE OF STRUCTURE: jiFSingle Family Dwelling I )Other% Do you plan any furthe dltions to the residence? ( )YES )NO No. of bedrooms ­� No. Of Lofts �J No. of Garbage Disposals / No. Of Automatic Dishwashers Ro, of Autonatic Clothes Washers s� //- Y �g ' ��% A J WATER SUPPLY: %)Private Well, Depth `�/ Q or t )Pu blic, Name of Systan ( )Spring �J C ( )Stream or Creek V D TYPES OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED: /'% septic Sank/Absorption Field ( )Aeration Plant/Absorption Field ( )Composting Toilet ( )Incineration Toilet ( )Mound ( )Recycling, potable use ( )Recycling, other use ( )Vault Privy ( )Other. The initial site inspection must be arranged with the Aspen/Pitkin Envlromsental Health Department (925-2020, 8:30-9:30 a.m.) be Core a permit can be issued. The individual sewage disposal permit must be Issued before a building permit can be obtained. FINAL INSPECTION APPROVAL MUST BE GIVEN BY THE ASPEN/PITKIN ENVIRONMENTAL HEALTH DEPARTMENT PRIOR TO BACKFILLING ANY PORTION OF THE SYSTEM. Application for an individual sewage dim p permit is hereby submitted. The undersign d acknowledges that the above information is true and that false informatio 1 validate the application and any subseguent p rmit. Signature of Applicant DATE (This application becomes. invalid 12 months from the above date.) NOTE: PLOT PLAN must be filed with this application. Please locate the following items by measured distances: 1. Property lines and dimensions. 2. Proposed and existing water wells on subject property and adjacent property. 3. Domestic water service lines. {. Proposed and existing buildings, driveways, and other structures. 5. Streams, lakes, ponds, irrigation ditches, and other water courses. 6. Proposed and existing individual sewage systems on subject property. SUBMIT A REVISED PLOT PLAN PRIOR TO CONSTRUCTION IF INSTALLATION IS TO BE CHANGED FROM ORIGINAL PLAN. The undersigned Mreby acknowledges receipt of this lndivldcal sewage dispasel permit application and a permit fee in the amount of 3 .f-�. ov Receipt Number Date Fee Received �0 -07'/� by �' Adm %Hist Cativo O[[Lccr 3 130 South Galena Street Aspen, Colorado 131611 303/920-5070 • ASPEN*PITKIN • 3 1�0 ENVIRONMENTAL HEALTH DEPARTMENT -fPE5 OF INDIVIDUAL SEWACE DISPOSAL SYSTEM PROPOSED$ XSeptic Tank/Absorption Field ( )Aeration Plant/Absorption Field ( )Composting TOLIst ( )Incineration Toilet ( )Mound 1 )Raryeling, potable use ( )Recycling, other use ( )vault Privy ( )Other, :he initial site inspection must be arianged with the Aspen/Pitkin Envirommental Hcalth Department (915-1030, 0s30-9:10 a.m.) cfore a permit can be issued. The individual sewage disposal permit oust be issued beforo a building permit can be obtainad, 'INAL INSPECTION APPROVAL MUST RE GIVEN BY THE ASPEN/PITKIN ENVIRONMENTAL HEALTH DEPARTMENT PRIOR TO DACKFILLING ANY PORTION :F THE SYSTEM. .9ion for true individual 1nl pia sewage ws�spermit sand hereby cany subsoquentundersigned armlt�knowledges that the above information 9 trueand that falsoill alldatetheapplication agnaturt of Applicant / DATE G (This application becomes. invalid 11 months from the above date.) NOTE: PLOT PLAN must be filed with this application. Please locate the following Stems by measured distances: 1. Property lines and dimensions. 2. Proposed and existing water wells on subject property and adjacent property. J. Domestic waterservicelines. 4. Proposed and existing buildings, driveways, and other structures. 5. Streams, lakes, ponds, irrigation ditches, and other water courses. 6. Proposed and existing individual sewage systems on subject property. , SUBMIT A REVISED PLOT PLAN PRIOR TO CONSTRUCTION IF INSTALLATION IS TO BE CHANGED FROM ORIGINAL PLAN. the undersigned hereby acknowledges receipt of this individual sewage disposal permit application and a permit fee in the amount Receipt Number Date Fee Received - �� .by j-'li � Of Ste.__ Administrative officer 130 South Galena Street Aspen, Colorado BlES11 303/925-.2020 APPLICATION FOR AN INDIVIDUAL SEWAGE DISPOSAL'PERMIT AT6i Name of OWNER �, Irk %- P]i/ l urnc// PHONE Address of OWNER 3.23 FL—c 5,2✓c,-{ ca Cc /2r i0[.(rnel/ PHONE �Z2s-6o2,31 Name of APPLICANT ,// ERMfT TO DEI 0 Picked Up � ( )Nailed tot TYPE OF PERMIT, (Yl Nev Inetallatlon ( )Repair //-- ( jowner ( )Applicant , ( )r"rgency use ( )Alteration NOT due to failure .00ATIOH OF PROPOSED SYSTEMS .egal Description Scc,& /t -.TOW "J 1+YY� �c-�f(.r RA,�r O.SW(eY 0�- ,iLG %• pilhG,17�� /ilei z� w Block Filing subdlvlsionl)i%/r p/, / CN( S sire of Lot , 0 y acres nt YPE OF STRUCTURE, c�tingle Family Dwelling ( )Others //`� to the Do you plan any Lurcher additions resldence7 ( )YES ( )NO ;o. of bedrooms S ' No. of Lofts No. of Garbage Disposals / No. of Automatic Dishwashers lo. Of AatamaLLe Clothas Washers EATER SUPPLY, y7 �PrivaU5^ta wall, Depth 0 I �• or ( )Public, Name of System C )Spring .. • ( )stream or Crack -fPE5 OF INDIVIDUAL SEWACE DISPOSAL SYSTEM PROPOSED$ XSeptic Tank/Absorption Field ( )Aeration Plant/Absorption Field ( )Composting TOLIst ( )Incineration Toilet ( )Mound 1 )Raryeling, potable use ( )Recycling, other use ( )vault Privy ( )Other, :he initial site inspection must be arianged with the Aspen/Pitkin Envirommental Hcalth Department (915-1030, 0s30-9:10 a.m.) cfore a permit can be issued. The individual sewage disposal permit oust be issued beforo a building permit can be obtainad, 'INAL INSPECTION APPROVAL MUST RE GIVEN BY THE ASPEN/PITKIN ENVIRONMENTAL HEALTH DEPARTMENT PRIOR TO DACKFILLING ANY PORTION :F THE SYSTEM. .9ion for true individual 1nl pia sewage ws�spermit sand hereby cany subsoquentundersigned armlt�knowledges that the above information 9 trueand that falsoill alldatetheapplication agnaturt of Applicant / DATE G (This application becomes. invalid 11 months from the above date.) NOTE: PLOT PLAN must be filed with this application. Please locate the following Stems by measured distances: 1. Property lines and dimensions. 2. Proposed and existing water wells on subject property and adjacent property. J. Domestic waterservicelines. 4. Proposed and existing buildings, driveways, and other structures. 5. Streams, lakes, ponds, irrigation ditches, and other water courses. 6. Proposed and existing individual sewage systems on subject property. , SUBMIT A REVISED PLOT PLAN PRIOR TO CONSTRUCTION IF INSTALLATION IS TO BE CHANGED FROM ORIGINAL PLAN. the undersigned hereby acknowledges receipt of this individual sewage disposal permit application and a permit fee in the amount Receipt Number Date Fee Received - �� .by j-'li � Of Ste.__ Administrative officer 130 South Galena Street Aspen, Colorado BlES11 303/925-.2020 Li w6 l ,2-s-rozY ��o �" Ffl�s1 PPR �- � •• •rs�L(al TPEF M pA,e FArr vsEv SMP �!T o F AS �o ANG �nJ • ASPENOPITKIN • ENVIRONMENTAL HEALTH DEPARTMENT Legal dec Name of C Address: FIELD TEST DATA SHEET Name of Agent: Water Supply: Public Utility_ Sub ivisi n Private Well_ � 1O 4--s.-6 Lot Area: 75 x 30.0 Distance to ea est Surface WaterD ft. Dates Observations Made: Soil Borings: 9 D by Percolation Tests: - - by SOIL BORING TESTS MAN AAIN ININIMI ■11i liMi[1€ i it Ivan INNINNININ III A Imam also RINI AMA TUT Te T.a DU Tw D[.Tw TO !ro!u wo[., "" OD!(IIY [e aID w1111 I.IM.T YVM!(• I{[• CM 1..0 T[L OI <DIL SITE \M if Lw [L! Iw Il [T B-1 .... L • TT. 5 /^ B-2 <M. Y.1(T(Y O• IIIC[M -L-NT OI.... t. Ia INNIMMIN ililii[A!■ Malawi, i[.lil■ W� i■leis€■i�€�€Iiiiii€iHii[If[[M�iiiii��ffi PERCOLATION TESTS dl li■ lEiii ■11i liMi[1€ i it ■Ili ilii! w4momfIRIMMIN ~-*' w.Tl. Till ar[ aro. n w.Taw Lo (L, l.{.[! wIIIDn• .... L • TT. L.., •C!T y <M. Y.1(T(Y O• IIIC[M -L-NT OI.... t. Ia MVU ICD oYCx[L TwICCY[!! IY IY <M{! IfC 11CT OINIT Y IYVT[ LAST I(LI00 LAST .[.IOD •[11100 0. 4.(/1 I I I P-1 ZO S 6 P-20 P-3 P-4 MAINE RINI NIXON ■;[1€iiIIII IR Average Rate: A minutes/inch Plan ofthe, site on the back %��% Date Sign aturez/X 8106 NELSON .+S ,EN/PITKIN SAr4ITARIAN 130 S. GALENA ASPEN, CO 81611 0 V SCMMUESER MEYER June 18, 1990 Mr. Todd Habermann Box 1210 Basalt, Co. 81621 RE: Purnell Residence Dear Todd Grand Avenue, Suite 2-E Glenwood Springs, Colorado 81601 (303) 90.5-1004 (303) 925.8501 Fax (303) 9455948 CONSULTING ENGINEERS i This letter is in reference to Individual Sewage Disposal Systems (ISDS) alternatives of the Mark and Kelley Purnell residence located at 105 Little Texas, Pitkin County. The reference in the Pitkin County Building Department is No. 1020. This analysis is based on site visit with yourself several weeks ago as well as my understanding of the proposed construction. It is my opinion that an engineered system can be designed and cosntructed on this property to meet Pitkin County Environmental Health Standards. I would anticipate that the engineered system would either be a mound system or an evapo-transporation (ET) system, both located ont he lower bench, adjacent to the Roaring Fork River but above the 100 year flood plain line. Additionally, I would anticipate that a septic tank would be constructed on the upper bench of the property immediately adjacent to the residence. Based on percolation tests conducted by the Envrionmental Health Officer, it would appear that the primary restraint on the property is high ground water table rather than the lack of a percolation rate. This is also to indicate that Schmueser Gordon Meyer, Inc. has been retained by yourself to provide the engineering services in conjnction with the ISDS. That design will begin once more detain has been generated with respect to an architectual site plan and architectual details. I trust that the above is sufficient for you process through the building department. answer any further questions that either department might have concerning this site. Sincerely, SCHMUESER GORDON MEYER, INC. P.E. to begin the permitting I will remain available to yourself or the building Iii 130 S. Galena ASPEN* P11 COMMUNITY DEVELOPMEM DEPARTMENT General '4spen,,CO 81611 PERMIT APPLICATION Permit 970/920-5090 920-5448 Inspection line PITKIN COUNTY X CITY OF ASPEN ❑ /j_ / ^ Applicant to complete numbered Spaces only, No. JOB ADDRESS 1.B SO LEGAL LOT NO. 2. DESC. BLOCK TRACT ORSUBDMSION 13 ME ATTACHED SHEET) I CO_ DE OWNER MAILAODRESS ZIP PHONE 3.MAIZK p FD CONTRACTOR AWL ADDRESS LICENSE NO 4. FN ARCHITECT OR ENG EER OF RECORD MAIL ADDRESS P LICENSE NO MH 5. MS DESIGNER MAILADDRESS PHONE LICENSE NO 6. RF CLASS OFR' 7. 13NEWWO ADDITION ❑ ALTERATION ❑ REPAIR ❑ G�Y1 C'O'OTS FEE " L E/�jE v / U USE TAX CENSUS CODE USE OF BUILDING 8. 5 NJ PICHECK FEE '.(0 Volo. ZONING FEE VALUATION OF WORK 9. $ w SGUARE FOOTAGE 10. P. of ComoacMon DecupeuyG° P otArea 11. Is there food service in this building ❑ YEs No 12. Is LPG used? ❑ YEsi(No NO.OF BEDROOMS Uea Zale Rn SpnnWrs ReRlmM ❑Ym ❑N° 13. Remarks EX snND Aoom AImm SVslem RagwedT ❑Ym ❑Na - Coola=rAVOID No. of OweWrg Unim OFFSTRE(T PARKING SPACES gonna <6LAaA&1-E Cmared LAnovered II I'ROVALS REWIRED AUTHORIZED BY DATE -)OA to5 ZONA H.P.C. PARK DEDICATION ENNRO. HEAL y v 9 PRFSUBMIiAL PPPIJCATpN P�C�I� BANS CHECKED APPRWFD rORISSWNCE ENGINEERING IAt// PARKS BY I BY BY BV MARSHAL fFIRE DATE lAb DATE DATE WATER TAP NOTICEASPEN CONSOL SAN. DIST. i ARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING, VENTILATING OR AIR CONDITIONING. �� _ THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION PAYMENT OF PITKIN COUNTY USE TAX AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. ❑ MONTHLY OR QUARTERLY RETURNS WILL BE SUBMITTED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PRO- ❑ DEPOSIT METHOD 3.5 % OF 25% OF THE PERMIT VALUATION PAID AT ISSUANCE. A FINAL REPORT ON TOTAL ACTUAL COST MUST BE FILED WITH IN 90 DAYS OF SUBSTANTIAL COMPLETION OF BORLAND/ORISSUANCEOFT BSTANTIAL CO PLOF OCCUPANCY. VISIONS OF ANY OTHER STATE OR LOCAL LAW REG TING CONSTRUCTION OR THE PERF ORMAN E FCO STRUCTION. IT I MY RESPONSIBILITY TO ❑ EXEMPT: EXEMPT ORGANIZATION REVIEW THE AP N AND OM S THAT AR COM NED THE ON ICD ATT ST RE /Ofl PRO IS B LT IN ❑ RESALE: STATE 6 PffKIN COUNTRY RESALE NO. �0 I LL S ANYONE WHO USES AND / OR CONSUMES BUILDING MATERIALS AND FlXTURES IN / PITKIN COUNTY IS SUBJECT TO THE 3.5% USE TAX, sIDNAruRE OF NTMCTON ( PROPERTY LIENS MAY BE PLACED ON THE OWNER'S AND /OR THE CON- TRACTOR'S PROPERTY WHEN USE TAX IS NOT PAID SIGNARIRE aF OVMEP IIF OWNER 6UWDFA) (DAT THIS FORM IS A PERMIT ONLY WHEN VALIDATED Energy Code Validation i O WORK STARTED WITH OUT PERMIT WILL BE DOUBLE FEE Validation Zoning Validation Permit Validation 3.5 % Use TM Deposit Validation 60 CANARY -APPLICANT • 0 September 18, 1990 To: Pitkin County Environmental Health District Re: Unused well on the lower bench of Lot 5, Little Texas The well on the lower bench of our property which is Lot 5, Little Texas is not being used for household purposes. It was used in the past and may be used again for irrigation of that area. There is a well on the upper bench for the domestic use of Lots 4, S, and 6. Thank you, L. V. Anderson 4 DESIGN CALCULATIONS 1. DETERMINE FLOW TO FIELD (AVERAGE DAILY) 5 BEDROOM HOUSE 2 PERSONS/BEDROOM 75 GPC/DAY 5*2*75= 750 GPD 2. PERCOLATION RATE FROM FIELD DATA IS 15 MPI ALLOWABLE LOADING RATE(NATIVE MATERIALS) = 0.72 GAL/SF./DAY ALLOWABLE LOADING RATE(SAND) = 0.95 CPD/SF. J. CALCULATE FIELD SIZE: DETERMINE BOTTOM OF BED AREA: AREA = 1.95 * 750 - 0.055 * 750 = 1990.0 SF 0.72 USE 34' X 59' BED AREA (EFFECTIVE AREA = 2006 S.F.) 4. CALCULATE FIELD SIZE FOR DOSING OF BED: Q(AD✓)= 750-0.20(750)= 600 GPD A= 1.95(600) 0.055(600) = 1592 SF 0.72 USE A BED SIZE OF 27 x60 GENERAL N07ES: 1. ALL MATERIALS, INSTALLATION PRACTICES, SETBACKS, ETC. SHALL CONFORM TO PITKIN COUNTY INDIVIDUAL SEWAGE SYSTEM REGULA 77ONS. 2. THE CONTRACTOR AND OWNER SHALL TAKE WHATEVER MEASURES ARE NECESSARY TO ASSURE THAT (A) THE SEPTIC TANK AND SEWER LINES ARE COMPLETELY WATER– 77GHT TO PREVENT INFILTRATION OF GROUNDWATER INTO THE SYSTEM, AND (B) THE SYSTEM IS TO BE INSTALLED TO PREVENT FREEZING OF GRA PTY SEWER LINES: J. THE COUNTY ENVIRONMENTAL HEALTH DEPARTMENT SHALL BE NO77FIED WHEN CONSTRUCTION COMMENCES SO THAT THE SYSAFM CAN BE INSPECTED AT REGULAR INTERVALS TO ASSURE CONFORMANCE WI7H THESE PLANS. 4. STONE SHALL BE 3/4" TO 2 1/2" CRUSHED ROCK. 5. THE AREA DISTURBED BY CONSTRUCTION SHALL BE RESEEDED WITH NAT/lE GRASSES TO PREVENT EROSION. 6. USE RISERS AS NEEDED TO BRING SEPTIC TANK ACCESS HATCH WITHIN 6' OF FINISHED GRADE. 7. THE FOLLOWING PREVENTIVE MAINTENANCE SCHEDULE IS RECOMMENDED TO PROLONG THE LIFE OF THE SYSTEM: (A) PUMP SEPTIC TANKS ONCE A YEAR. (B) CHECK PLUMBING FIXTURES ON A REGULAR BASIS AND REPAIR ALL LEAKS WHICH CAN ADD SUBSTANTIAL AMOUNTS OF WA 7ER TO THE SYS MY B. CAST IRON PIPE OR PIPE OF EQUAL STRENGTH OR OTHER PIPE PROPERLY SUPPORTED TO PREVENT FAILURE BY SET7ZING SHALL EXTEND FROM SEP77C TANK FOR A DISTANCE OF AT LEAST FIVE (5) FEET FROM THE INLET AND OUTLET ENOS 9 . 71 -IE LOCATION OF THE FIELD AS DRAWN MAY BE ADJUSTED ON THE SI TF TO BEST FIT THE S1 TE IT MUST BE NO7ED THAT FIELD ADUSTMFNTS MUST .STIII BF ,.dAnF V/,"" THAT SETBACK REQUIREMENTS ARE MAINTAINED. CONTRACTOR TO MINIMIZE THE REMOVAL, OR DES7RUC77ON OF EXISTING TREES AS MUCH AS POSSIBLE. 10. INSTALLA7701V OF LOW WATER USE FIXTURES WOULD RESULT IN THE REDUCTION OF FLOW BY 25 PERCENT. THIS WOULD ALSO RESUL F IN A FIELD SIZE REDUCTION OF 25 PERCENT. 11. DESIGN CONSIDERS WELL LOCATED ON ADJACENT / IS UTILIZED (OR ABANDONED) FOR IRRIGATION PURPOSES \ \ COT*NWOOD \ \ \ \ o \\ \ \ \ \ \ \ \ LOT 7 DOSING 'TANK \ 3" FINISHED GRADE LAP 10 MIL. PVC LINER REQUIRED AROUND PERIMETER OF BED 72" IAP 6' 6' I—NATIVE BACKFILL o J0 QC 6" MIN. U 000 24" SAND 4" PERFORATED PVC SLOPE 0'/FT (TYP.) BED SECTION. - N. T. S. MIRAFI 14ON FILTER FABRIC OR EOUAL OVER GRAVEL 12' OF /2" TO 2-1/2" CLEAN ROCK SCALE. I "= 10 CONTOUR INTERVAL 2 0 NOTE: BED TO BE MINIMUM 10' FROM ALL PROPERTY I 3200 LINES. BED TO BE M/N/MUM 20' FROM _ _ , - IL O T 5 / HABITABLE STRUCTURES. SEPTIC TANK TO BE MINIMUM 5' FROM HABITABLE STRUCTURES. BED TO BE 50' FROM ORDINARY HIGH WATER LINE OF ROARING FORK RIVER. / NO 7E- CONTRACTOR AND OWNER TO VERIFY THAT FACILITIES DRAWN DO NOT CONFLICT WITH / OTHER CONSTRUCTION PROPOSED. SINCE NO DETAILED GRADING PLAN EXISTS, CONTRACTOR AND OWNER TO VERIFY THAT EXISTING AND PROPOSED GRADES ARE COMPA TABLE WITH / MINIMUM SL OPES AND L OCA TIONS OF FA CILI TIES DRAWN. CONTACT ENGINEER IF CONFLICTS ARISE. / 11 NOTE: SAND SHALL BE 0.5 TO 1.0 MM EFFECTIVE SIZE WITH / T4Y" SPRUCE LOT n A UNIFORMITY COEFFICIENT OF 4 OR LESS. PROVIDE \ SIEVE ANAL PSIS TO ENGINEER FOR REVIEW. \ / NOTE. PROVIDE CLEAN OUTS AT EVERY CHANGE IN \ \ DIRECTION (BOTH VERTICALL Y AND HORIZ- ON TALL Y). \ \ \ i 800.6 \ V A \ V A 00 10 MIL. PVC \ �\ \ \ \ \ \ \ \ \ \ \ \ \ 20" SPRUCE / / LINER REQUIRED �\ o\ \ \ p \ \ J�LOPE 0 0 27 x 60' BED - 10 MIL PVCJ LINER REQUIRED 1 � NATIVE BACKFILL 70 o SEE BED SECTION NOTE- THE DISPOSAL BED LOCA MIV MAY BE FIELD ADLUSTED / 10 MIL. PVC LINER REQUIRED SITE PLAN SCHMUESER GORDON MEYER INC. 1001 GRAND AVENUE, SUITE 2—E GLENWOOD SPRINGS. COLORADO 81601 (303) 945-1004 ASPEN, COLORADO (303) 925-6727 TO MINIMIZE REMOVAL OF.rXISTING TREES. HOWEVER, 7HL FINAL BED LOCAno1vVUST MAINTAIN ALL REQUIRED SETBACK DIMENSIONS DATUM EL_EV_ 60.00 -- LINER - SEE BEO SECTION ASTd 3034 PVC - FEEOER LINE FROM DOSING TANK. 4 " /6 DIA. WASTE LPI£ FROM HOUSE CONNEC75 TO HOXE VENT SY57EV PK' SLOE C. P;PE 5 MK 4" PERFORATED PVC SLOPF O'%FT (TYP.) SEE BED SECTIONS FOR SPACING 4" SOLID WALL HEADER (ASTM 2729) NOTE: SKETCH SHOWN IS SCHEMATIC IN NATURE, APPLICABILITY TO EACH SITE MAY VARY. TYPICAL LATERAL INSTALLATION DETAIL N. T S. `-FAOSHED GRADE is 20 - Da ACCESS HATCH, W/ RASER REMOVE SAFFL 3RLNG wm*v 6- OF FYNShED GRADE q�VE �.. SIPHON 4"PVC .. ..-.-.. � SPHOY STARTS I 1000 GALLON Irl. PIPE OPERATION I SEPT7C E7YeV SIPHON ENDS� RAT/ON ' HOUSE B4FFLE .: 24 ` DIA RISER PIPE -GROUT HOG£ OVE)zq-ow PPE ,PROVl)6 K,VOCXCUT AS AECE55ARY TO DLSTR/BU- rION Box `+ 2W STAGE CONCRETE T— CJ. PIPE FOR 5' OR UNTIL SOLID GROUND /000 GAL. CONCRETE SEPTIC TANK 1.6ED USE S4FFL£ BELOW SIPHON FOR DOSING TANK FOR FORM OF 210 STAGE CONCRETE T YR. INSTALLATION OF TANKS & DOSING SIPHON N TS CLEAN-OUri DETAIL .90. EXISTING GRIDS I DOWNHILL EDGE OF HOUSE i 100 � I 4" DIA. ASTM 3034 SEWER PIPE - 1250 GALLON CONCRETE SEPTIC TANK 80. 4" DIA. ASTM 3034 SEWER PIPE 1000 GALLON DOSING TANK / 1 10' HORIZONTAL 1 - 5' VER77CAL 4"" DIA. ASTM. 3034 SEWER PIPE t PROVIDE BENDS AS NECESSARY APPROX.. LEVEL OF. GPOUNDWATER ... — ... _ 7�... — ... — ... — ... EX1S77NG GRADE ELEVATION � rn ocl EXISTING GRIDS I DOWNHILL EDGE OF HOUSE i 100 � I 4" DIA. ASTM 3034 SEWER PIPE - 1250 GALLON CONCRETE SEPTIC TANK 80. 4" DIA. ASTM 3034 SEWER PIPE 1000 GALLON DOSING TANK / 1 10' HORIZONTAL 1 - 5' VER77CAL 4"" DIA. ASTM. 3034 SEWER PIPE t PROVIDE BENDS AS NECESSARY APPROX.. LEVEL OF. GPOUNDWATER ... — ... _ 7�... — ... — ... — ... EX1S77NG GRADE ELEVATION 0400 P URNELL RESIDENCE 7+00 SEC TICN A —A BER REVISION DATE BY lob 9245 IIVDI VID UAL ,-)-L- 'A GE Drawn by: MH DISPOSAL /SYSTEM Date 711 JI90 ,—A Appr. by: JSS OF � rn ocl 0400 P URNELL RESIDENCE 7+00 SEC TICN A —A BER REVISION DATE BY lob 9245 IIVDI VID UAL ,-)-L- 'A GE Drawn by: MH DISPOSAL /SYSTEM Date 711 JI90 ,—A Appr. by: JSS OF