Loading...
HomeMy WebLinkAboutpitkin.eh.264316101006 (2008)-MEMOEg THE LOCATION OF EXISTING AND PROPOSED IMPROVEMENTS SHOWN ARE NOT THE RESULT OF A PROPERTY SURVEY. THE LOCATIONS ARE APPROXIMATE. IT IS THE HOMEOWNERS DUTY TO ENSURE ALL CONSTRUCTION AND IMPROVEMENTS LOCATIONS ARE ACCURATE. ALL SETBACK DISTANCES SHOULD BE CONFIRMED PRIOR TO EXCAVATION. PUMP HOUSE HIGH WATER FOR ROARING FORK RIVER 2" SCHEDULE 40 PIPE TO DRAIN FIELDS OBSERVATION PIPE 4" PVC SEWER PIPE WITH CLEANOUT (2% FALL TO TANK) EXISTING 1000 -GALLON SEPTIC TANK rO BE ABANDONED SCALE 1"=20' NORTH 2000 -GALLON, TWO-COMPARTMENT PRECAST CONCRETE SEPTIC TANK WITH AX -20 ADVANTEX SECONDARY TREATMENT UNIT. PARKING AREA CHAMBER BED. THE BED MUST HAVE 6 ROWS OF 12 CHAMBERS FOR A TOTAL OF 711 SF INFILTRATCR(R) QUICK4(TM) CUT SHEET 12" ,= 34° 52"- 48" CTIVE LENGTH) FINISHED GRADE 4 FEET MIN SEWER LINE - 4" SCHEDULE 40 P.V.C. SLIP-ON PVC CAP DO NOT GLUE EFFLUENT LINE -4"SCHEDULE 40 OR 4" SDR 35 P.V.C. INSULATED COPPER TRACER WIRE MAY BE INSTALLED TO LOCATE LINE IN FUTURE r SWEEP / 2 WAY CLEANOUT DETAILS (N.T.S) TYPICAL AdvanTex Treatment System AX 20 Series - Mode 3a Filtrate Return Line ---� (minSlope. 1/8"/ft.) Inlet Inlet Recii with Inlet Discharge Filb To Drain Field AdvanTex g0" INFILTRATOR(R) QUICK(TM) 2" PVC CHAMBERS, 3' X 4' LEVEL MANIFOLD ---\ 2" EFFLUENT LINE TYPICAL PLAN VIEW - N.T.S. QUICK4(TM) END CAPS Dam, ADVANTEX-20 NOTES: 1. CONTROL PANEL SHOULD BE MOUNTED IN 'LINE OF SIGHT' TO TANK AND AX UNIT 2. DEDICATED 15A SERVICE FOR CONTROL BREAKER (IN OSI PANEL) REQUIRED. FOR 115V PUMPS A 20A. SERVICE IS SUFFICIENT. TANK SPECIFICATIONS CAPACITY REQUIRED = q X 1.5 X (30 HOURS/24 HOURS) = 1407 GALLONS REQUIRED TANK = 2000 -GALLON, TWO-COMPARTMENT, CONCRETE SEPTIC TANK WITH AX -20 UNIT. 2" No. Vent Dia. PVC Riser/Lid ;ompertment Tank _._.ube® Pump Package OBSERVATION/VENT PIPES (TYP.) it II End View CROSS SECTION OF TYPICAL CHAMBER -TRENCHES BACKFILL 4" SDR 35 PVC COUND FREE OBSERVATION/VENT F LARGE COBBLES PIPE WITH CAP 0 0 o 0,., o EXTENT OF EXCAVATION Ilk,_ ^PIFY SURFACE PLACE 6" OF SAND/ BENEATH BED MUST BE LEVEL CHAMBERS DESIGN NOTES: 5 -BEDROOM MAIN RESIDENCE, <6000 SF 3.7 2 -INCH PERFORATED LATERALS SUSPENDED WITHIN THE CHAMBERS ENTIRE LENGTH. THE LATERALS MUST HAVE 1/4 -INCH HOLES ON 1 -FOOT CENTERS FACING DOWN. PLACE CAP AT END OF EACH PIPE. EXISTING GRADE INFILTRATOR(R) QUICK4(TM) CHAMBER, 3' X 4' BED MAY BE ANGLED TO FIT TOPOGRAPHY AND TO MINIMIZE AVERAGE LOADING = q = 750 GALLONS PER DAY REMOVAL OF EXISTING VEGETATION. PERCOLATION RATE = 11 MINUTES PER INCH CALCULATED AREA = ((1.5 X q) X sgrt 11 / 5 = 747 SF THE SLOPE AT THE PROPOSED DRAIN FIELD IS APPROXIMATELY 5% TO REDUCTION OF 10% DUE TO CHAMBERS IN BED = 672 SF THE SOUTHWEST. VEGETATION CONSISTS OF A FULL COVER OF IRRIGATED GRASSES. BED SPECIFICATIONS LIMITATIONS - THESE PLANS MUST BE USED IN CONJUNCTION WITH WIDTH OF BED = 18 FEET = 6 CHAMBERS LETTER AND SOILS DATA FORM PROVIDED. THE DESIGN IS BASED UPON LENGTH OF BEDS = 48 FEET = 12CHAMBERS INFORMATION SUBMITTED. IF SOIL CONDITIONS ENCOUNTERED ARE TOTAL NUMBER OF CHAMBERS =72 DIFFERENT FROM CONDITIONS DESCRIBED IN REPORT, ALL SERVICE TOTAL INFILTRATIVE AREA = 711 SF SEPTIC L.L.C. SHOULD BE NOTIFIED. ALL OWS CONSTRUCTION MUST BE ACCORDING TO COUNTY REGULATIONS. THE INSTALLER SHOULD HAVE ONE TOTAL BED DEMONSTRATED KNOWLEDGE OF THE REQUIREMENTS AND REGULATIONS OF THE COUNTY IN WHICH THEY ARE WORKING. THE COUNTY AND ALL SERVICE SEPTIC L.L.C.MUST VIEW INSTALLATION ALL SERVICE septic, LLC 0101 LITTLE TEXAS LANE _ PROJECT N0. 1518 °E NOODSPRINGS, C081602 PITKIN COUNTY, COLORADO UPGRADE ONSITE WASTEWATER SYSTEM DESIGN 08/08/08 970-618-5033 KEMPNER RESIDENCE