AGENDA ITEM SUMMARY WORK SESSION DATE: November 1, 2016 AGENDA ITEM TITLE: Energy Code Addendum STAFF RESPONSIBLE: Brian Pawl, Pitkin County Chief Building Official ISSUE STATEMENT: The purpose of this work session is to discuss the proposed local Energy Addendum as an accompaniment to the recently adopted 2015 International Energy Conservation code (IECC). A series of work sessions began on June 28th with a Matrix of energy code options and strategies that was created to aid in the discussion process and became the structure for the Matrix rewind. (Attachment#1) A Renewable Energy Mitigation Program(REMP) focused presentation was the topic of the July 19`h work session which laid out the initial ground work for the overall REMP discussion which was continued at the August 9th work session. (Attachment#2) Today we will be discussing the culmination of the previous work session topics to create an adoptable ordinance that enhances the current 2015 International Energy Conservation Code, supersedes the Efficient Building code and updates the Renewable Energy Mitigation Program ordinance. BACKGROUND: The BOCC reviewed the introduction and slides of the Matrix at the 6/28/2016 work session stopping before the Mechanical Systems slide. The Review continued on 7/12/2016 from the Mechanical System slide to the REMP overview slide. The REMP discussion at the 7/19/2016 work session covered the background on how the program functions today and some areas that could be the focus of future changes based on the BOCC direction. The 8/9/2016 discussion covered sections of the REMP program that the Energy Addendum group would like to update or create. LINK TO STRATEGIC PLAN: Flourishing and Natural Environment/Conserve natural resources and the environment. KEY DISCUSSION ITEMS: 1. A brief recap of the August 9, 2016 work session and the further Round table discussion that followed with members of CORE, a Consultant, City Staff and County Staff. 2. Staff would like to dedicate the Energy Addendum in memoriam to a local champion of Energy and Sustainability, Michael Augello: "The main thing we want to stress is there is an alternative to throwing everything in the dumpster and taking it to the landfill. "—Michael Augello, 1 of 30 VP Wodehouse Builders Aspen Times, November 25, 1999 He not only believed in building as efficiently as possible, but also helped pioneer new green standards such as de-construction. 3. The Matrix rewind. Staff has attempted to compile a working document from the direction received from the BOCC and the Addendum Team's desire to produce a functional and effective above code ordinance that demonstrates Pitkin County's commitment to energy efficiency and sustainable construction methods. 4. REMP definition..."The intent of the REMP program is to encourage on- site offset of energy used for energy uses including: houses over 5000 square feet,snowmelt,pools, and spas. If a project opts not to install renewable energy systems on-site to mitigate energy use, a fee equivalent to the cost of offsetting that energy consumption for a period of 20 years is to be paid into the REMP fund. These fees are to be used to install renewable energy production in other locations and provide funding for renewable or efficiency projects throughout the Roaring Fork Valley through collaboration and partnerships." - Energy Addendum Team 5. REMP ordinance edit. Staff has updated sections of the REMP program to reflect an adjustment to the original document using similar logic paths. The intended goal was to analyze the existing credit and offset calculations and revise them as well as addressing items such as existing system credits, house size and heat tape system offsets. 6. The Landfill White Paper on construction waste—summary. 7. 2015 IECC cost study for Colorado - summary. BUDGETARY IMPACT: Use of a Community Grant from CORE for Training, Education, Public Outreach and associated Staff Time. RECOMMENDED BOCC ACTION: Staff's recommendation is for the Board of Commissioners to participate in a discussion of this initial draft and offer guidance and direction regarding goals and concerns. Staff will further refine key decision points as the review continues based on the BOCC direction with public input and present a completed ordinance at a future regular meeting. ATTACHMENTS: #1 the Matrix rewind; #2 REMP ordinance with revisions; #3 Michael Augello article clipping; #4 Landfill White Paper; #5 cost study; #6 Boulder Deconstruction document; #7 Appendix RB—2015 IRC 2 of 30 DRAFT VERSION Building Size <2,500 ft2 2,500 to 5,000 5,000 to 7,500 7,500+ft2 Staff comments and explanation of compliance path Insulation R-Values Continuous Insulation(C.I.)as a driver for increased R value at exterior wall for larger homes.Equiv=full depth foam,or SIPs or some other pre-defined Walls NA NA C.I.or equivalent C.I.or equivalent wall methodology.Can't just do a UA trade off. Windows If using ERI path,need to run a number of example models to see what the ERI should be,and look for loop holes in that modeling process. Refer to Max.Glazing >15%* >15%* >15%** >15%** sustainable options below. Max.U Value 0.28 0.28 0.24 0.24 ONLY apply for>15%,this becomes the new prescriptive value.ERI is also an alternative pathway.(These U value numbers need study and review) Numbers need study,maybe reduce U and SHGC for 7,500 ft2 and above. Should we tie it to SF of glazing(over 15%)? The more the glazing the lower Max.SHGC 0.3 0.3 0.25 0.25 the SHGC? There is a reason IECC doesn't require SHGC in this climate zone. Skylights ? ? ? ? Match all to window performance,regardless of home size or glazing ratio.Verify this is reasonable in terms of cost for small homes. *prescriptive values not allowed.Must use modelling or Total UA **prescriptive method not allowed. Must model using Energy Rating Index path Equipment Appliance Efficiency eStar eStar eStar eStar use E-star for applicable applicances,add categories E-star doesn't cover(e.g.water heaters) Boiler AFUE Min 92% Min 92% Min 92% Min 92% Furnace AFUE Min 92% Min 92% Min 92% Min 92% Water Heater Efactor 82 Efactor 82 Efactor 82 Efactor 82 Multiple Systems,or over 5 Multiple Systems,or over 5 Multiple Systems,or over 5 Multiple Systems,or over 5 thermal Commissioning thermal zones thermal zones thermal zones zones If more than 5 zones(heating or cooling)OR if multiple boilers OR heating and cooling Mechanical Rooms Sealed and Vented to Exterior Sealed and Vented to Exterior Sealed and Vented to Exterior Sealed and Vented to Exterior Vent to be continuous low,and thermally activated to high.NEED TO DEFINE FLOWS. Controls for HVAC system NA NA Mandatory Mandatory For over 5k:remote access(for owner/property manager)to t-sats requried. (programmable stats not typically useful for this home type) Controls for Snowmelt and Heat tape included in REMP included in REMP included in REMP included in REMP Some language is included:let's review.Add low temp cutoff language Control:self-regulating tape is required&control(timer or photo cell)to allow for operation only during daylight hours.REMP:Need to perform a calc to discuss annual exterior energy Btu per installed wattage.This then would become another exterior energy use in the REMP Controls for electrical heat tape included in REMP included in REMP included in REMP included in REMP calcs.Probably also allow a maximum wattage that is'free.'(controls are still mandated though). Upgrades to Existing Remodels affecting Building Envelope Prescriptive Minimum Insulation Prescriptive Minimum Insulation ERI ERI Mechanical system replacement meet current code meet current code meet curren code meet current code Remodels interior only I Remodels and Additions greater than 225 sf or 10%of existing floor area(whichever is less)requires the following to existing house: would need to have an energy assessment that addresses both the electrical and gas energy systems(if applicable)and the building Home Energy Assessment Required Required Required Required envelope with blower door test Existing house to be air sealed Existing house to be air sealed Existing house to be air sealed Existing house to be air sealed with a with a minimum 15%air leakage with a minimum 15%air leakage with a minimum 15%air leakage minimum 15%air leakage reduction. reduction.Test-in of existing and reduction.Test-in of existing and reduction.Test-in of existing and Test-in of existing and test-out with Air Sealing test-out with addition required. test-out with addition required. test-out with addition required. addition required. Existing vented crawlspaces to be Existing vented crawlspaces to be Existing vented crawlspaces to be Existing vented crawlspaces to be converted to semi-conditioned converted to semi-conditioned converted to semi-conditioned converted to semi-conditioned spaces spaces to meet 2015 prescriptive spaces to meet 2015 prescriptive spaces to meet 2015 prescriptive to meet 2015 prescriptive crawlspace Crawlspace conversion crawlspace reqt's crawlspace reqt's crawlspace reqt's reqt's passively vented to the exterior crawlspaces converted to mechanical ventilation or conditioned space. Accessible existing vented attics Accessible existing vented attics Accessible existing vented attics are required to be brought to are required to be brought to are required to be brought to Accessible existing vented attics are 2015 IECC insulation levels and 2015 IECC insulation levels and 2015 IECC insulation levels and required to be brought to 2015 IECC provide sufficient ventilation provide sufficient ventilation provide sufficient ventilation insulation levels and provide sufficient Attic Insulation required by 2015 IRC. required by 2015 IRC. required by 2015 IRC. ventilation required by 2015 IRC. 75%of lighting must be high- 75%of lighting must be high- 75%of lighting must be high- 75%of lighting must be high-efficacy efficacy luminairs or LEDs,with efficacy luminairs or LEDs,with efficacy luminairs or LEDs,with luminairs or LEDs,with exception of Lighting exception of low voltage circuits exception of low voltage circuits exception of low voltage circuits low voltage circuits require testing >4 pci make require testing>4 make require testing>4 make require testing>4 make appropriate Radon VB and prepiping appropriate modifications appropriate modifications appropriate modifications modifications 3 of 30 Renewables Solar Hot Water Prepiping Prepiping Prepiping Prepiping Appendix RB with amendment for installing piping and conduit with size requirement Photovoltaic Conduit Conduit Conduit Conduit Appendix RB with amendment for installing piping and conduit with size requirement Electric Vehicle Charging Outlet wiring Would like to include somehow.Optional credit for installing?pre-wire requried?At what home size? EV charging require 240 in garage require 240 in garage Sustainable Construction Jobsite Waste Deconstruction Deconstruction Deconstruction Deconstruction Mandatory for all Demolition Permits Reduce,Reuse,Recycle Separation and Handling Separation and Handling Separation and Handling Separation and Handling Mandatory for all Demolition and Construction sites Sealed Ductwork Mandatory Mandatory Mandatory Mandatory Testing required?Currently only in unconditioned spaces. Boiler Operation Sequential Sequential Sequential Sequential Need to discuss further. Boiler Operation Outdoor Reset Outdoor Reset Outdoor Reset Outdoor Reset Anyway to push for a maximum operation temp? Use occupancy sensor with timer.Fan and timer combo to be sized to provided 1 ACH for each operation.(For example,1 600 ft2 garage,10 ft tall, Exhaust fan in Garage 1 ACH/Day 1 ACH/Day 1 ACH/Day 1 ACH/Day would require a 100 cfm fan to run for 1 hr). Driven by>15%glazing/house size Projects greater than 5000 square feet/>15%glazing must incorporate 2 of these options. Projects taking credit for C.I.equivalent must incorporate at Materials and framing practices Engineered Lumber Engineered Lumber Engineered Lumber Engineered Lumber least 3. Materials and framing practices Insulated Header Insulated Header Insulated Header Insulated Header Materials and framing practices 24"o.c.Framing 24"o.c.Framing 24"o.c.Framing 24"o.c.Framing Materials and framing practices Three Stud Corners Three Stud Corners Three Stud Corners Three Stud Corners Materials and framing practices SIPs or other SIPs or other SIPs or other SIPs or other 4 of 30 I 11.32: INTERNATIONAL ENERGY CONSERVATION CODE Section 101.1 Jurisdiction, Pitkin County Section 107.1 Fees is hereby amended and shall read as follows: "A permit shall not be valid until all fees as prescribed in the Pitkin County Community Development Fee Ordinance that is in effect at the time of permit submittal are paid in full, nor shall an amendment to the permit be released until the additional fees, if any, have been paid." Section 107.5 Refunds is hereby amended and shall read as follows: The building official shall authorize the refund for the full amount of any fe •, • which was erroneously paid or collected. Not more than 80% of a permit fee paid •_ • - n•ed when no work has been done under a permit issued in accordance with this ode. , e duilding official shall not authorize refunding any fee paid except when submitted o writ •n application filed by the original permittee not later than six months after the date of paym. . Refunds may be approved for up to 80% of a fee paid for ' . 1 P. i o refund will be approved when requested more than 180 days after the Certificate o . cu. cy or Letter of Completion is issued. Section 109 Board of Appeals Ill109.1 General is deleted in its entirety and , - . as follows: Appeals shall be in accordance with Pitkin County Code Title 11, C apt- I A, Section 112.1. Section 110 Liability to read as '•Bows. The Building Official or his auth zed representative charged with the enforcement of this code, acting in good fa' . and without malice in the discharge of his duties, shall not thereby render himself perso able for any damage that may accrue to persons or property as a result of any . o om _ •n in the discharge of his duties. • This code s• o .e construed to relieve or lessen the responsibility of any person owning, operatin: co olling any building or structure for any damage to persons or property ca se f •. -cts on or in such premises, nor shall the code enforcement agency, any mp • e• ereof, or Pitkin County be held as assuming any such responsibility or liability by . •n f the adoption of this code or by the exercise of inspections authorized and carried ou - -reunder, or by the issuance of any permits or certificates issued pursuant to this code. Section 301 Climate Zones shall be deleted in its entirety and shall read as follows: "The City of Aspen, Colorado and Pitkin County, Colorado shall use Climate Zone 7 in determining the applicable requirements from Chapters 4 and 5". Section 402.4.2 Air sealing and insulation is hereby amended and shall read as follows: 5 of 30 "Building envelope air tightness and insulation installation shall be demonstrated to comply with the testing option section 402.4.2.1. Section 402.4.3 Fireplaces is hereby amended and shall read as follows: New wood-burning fireplaces and gas log fireplaces shall have gasketed doors and outdoor combustion air. "Appendix A" "Residential Renewable Energy Mitigation Program" Section 101 SCOPE AND ADMINISTRATION Section 101.1 Scope. Residential snowmelt, outside pool, or outside sp tems and equipment may be installed only if the supplemental energy meets e -:uire ents of the Residential Renewable Energy Mitigation Program (RREMP) Appendix applies to all installations for which an application for a permit or renewal of an st : permit is filed or is by law required to be filed with or without an associated Buildin ' that include systems described in section 101.1. Section 101.2 Residential Renewable Energy itigation Program (RREMP) Option — Exterior energy use for residential snowmelt system- i door spas, and outdoor pools are calculated as directed by Section 201. AH: Does there d to sea reference to roof/gutter melt here? It has it's own section further down, butt . -rsg ions we have had, it in now being considered the same as any other exterior us:-_ f--/offset protocol. Also might need a definition of "snowmelt"versus roof/gutte Section 101.2.1. The maximum area of snowmelt is capped at 6,000 square feet per parcel. AH: — • 301.3 are exenip cap. Delete exce n SHP'.s Section 101. 0 insulation shall be installed under all areas to be snowmelted. R 5 insulatie a, - used when the insulation extends up the sides of the slab.AH: I recommend del: ® t � exception. Do you need to clarify that `effective R-value' products like radiant ba '- . i bubble wrap does not comply? Or is that just an enforcement issue? SECT• I► _101.2.XX All snowmelt systems shall employ controls which control slab temperature to a set temperature, no `idling' of slab systems (maintaining a minimum temperature) shall be allowed, presence of moisture must be detected for slab heating activation, and a-temperature cutoffs shall be employed to not allow snowmelting below 20F or above 40F. THIS LANGUAGE (OR SIMILAR) SHOULD ALSO BE ADDED TO THE CREMP, HOWEVER, WE SHOULD CONSIDER ALLOWING IDILING FOR CRITICAL SAFTEY ISNTALLATIONS, BUT THEN NEED TO DEFINE THAT IS A SIDEWALK CRITICAL? OR JUST THE ENTRY RAMP AT A HOSPITAL? SHOULD IDILING BE ALLOWED FOR 6 of 30 `CRITICAL' RESIDENTIAL APPLICATIONS? SHOULD ALSO CONSIDER LIMITING THE BTU CAPACITY FOR RESIDENTIAL SYSTEMS TO 125 BTU/FT2. How about limits around entry ways? Section 101.2.X?? Roof, gutter and other exterior melting options not defined as snowmelt. (AH: BETTER WORDING HERE?) 1. Electric roof and gutter deicing systems shall include automatic controls capable of shutting off the system when outdoor temperature is above 40 degrees F any s- +w 25 degrees F, or which limit the use of the system to daylight hours by o a programmable timer. [AH: Another good system control is a moisture sensor. .' t t as an option? Consider requiring the temp limit+ either moisture or timer.] g►. Ode. 2. Hydronic systems: Shall be considered snowmelt systems . 1 • ,11 omply with Appendix A "Residential Renewable Energy Mitigatio ro of the 2009 International Energy Conservation Code, as amended. o s is d other snowmelt system parameters apply. Section 101.3 On-site Renewable Credits Option — Renewa► c ''t options are calculated as directed by Section 301. lb Section 102 Payment option. The RREMP payme- opt sn i the difference in energy use calculated in section 202 and on-site renewable credits calculated in section 302 and shall be paid at the time of issuance of the building pe itThe payment, if any, is based on the amount of energy required, expressed as dollars .- u re foot, to operate the exterior energy use systems for 20 years (AH: Correct??).- N. .yment shall be made to an applicant that exceeds the energy use with on-site renewa, f - 'ts. •11 monies collected pursuant to this section shall be recorded in a separate fund . s' b. spent in accordance with a joint resolution by the Aspen City Council and Pitk'- + ty B+ard of County Commissioners. Section 103 Credits for on-site renewable energy. This RREMP payment option is voluntary. Applicants interested in 48i- 'or energy use systems can alternatively choose to produce on-site renewable energy (S- i• ' ) with solar photovoltaics and/or solar hot water or micro-hydro,. or reduce the - - • •- s ffset via reductions in the proposed size of applicable systems (AH: just a thought... o re if that's worth stating). The energy efficient technology of ground source heat p ps lso permitted for supplemental on-site energy. SE 3 .' RE-EXISTING SYSTEMS Pre-e 's ' g snowmelt, pools or spas Installed prior to Aspen Pitkin Energy Conservation Code (APEC adopted in 1995) which are being replaced, overhauled or renovated qualify for exterior energy credit. This credit can only be applied towards an installation of exterior energy on the same parcel. The calculation of the credit shall be based on section 301. The maximum allowable replacement credit shall be 6000 square feet of snowmelt (or 240,000,000 BTU's). The replacement credit may be applied to other exterior energy consumption. Systems installed after the adoption of APECC 1995 without permit approval are not eligible for replacement credit and are subject to all applicable fees. AH: This clause is allowing grandfathering, I 7 of 30 understood the BOCC wanted this deleted. Additionally, remodels/additions should be clarified as any credit being be pro-rated based on the date of CO, as a ratio of the 20 year period. I too thought we were eliminating the grandfathering of older systems when they were getting upgraded, enlarged, etc. The BOCC also suggested some sort of inspection of proper functioning for exterior energy systems (boiler plants etc.) and renewable energy systems upon transfer of properties. Should that go here? Could that be part of the inspection prior to sale? Section 105 -Residential repairs. Repairs to building components, systems, or equip e i h do not increase their pre-existing energy consumption need not comply with RREMP. replacement mechanical equipment shall be Energy Star©rated. Section 106 Residential Renewable Energy Mitigation Program (RREM . 'use 5,000 square feet and more. A new residence 5,000 sq ft or more in area(as `efine, .y e building code), or a residence receiving an addition which brings the area of esid- ,ce to 5,000 sq ft or more, is required to offset a portion of its fossil fuel energy consumptio eugh the use of on- site renewable energy or through a fee payment to REMP. R- e, .le energy systems installed for this requirement do not qualify for credit for exterior ener: us- Section 106.2. The on-site renewable energy requirement - et by the installation of a two- kilowatt solar photovoltaic or equivalent renewal) -n- I ystem. This requirement can alternatively be satisfied off site by payment of a REM fe- as follows. The fee for buildings over 4,999 sq ft shall equal the floor area as defedby the building code. For example: 5,000 sq ft $5,000 8,255 sq ft $8,25 AH: Are we using Btu's at all? .. , ,1 . For reference, the fee/ft2 based on the average ft2 of home, with the update. cost .1-rs is $72/ft2.... Section 201 EXTERIOR EN., USE °ALCULATIONS Section 201.1 Snowmelt energy consumption shall be calculated as a RREMP payment option at $34.00 $68.97 per squarOo divided by the boiler efficiency (AFUE). Do we want to present these as options? • Section 201.2 tde pool energy use shall be calculated as a RREMP payment option at $136.00 $27 ." p quare foot divided by the boiler efficiency(AFUE). Se . I . 'pa energy use shall be calculated as a RREMP payment option at $176.00 $3 . square foot divided by the boiler efficiency (AFUE). Package spas not more than 64 squar- f- are exempt. No more than one spa per property shall be exempt. Section 201.4 Roof, gutter and other exterior melting: 1. Electric systems: RREMP payment option at $5.87 per watt of installed electric heating element. 2. Hydronic systems: Shall be considered snowmelt systems and shall comply with Appendix A"Residential Renewable Energy Mitigation Program" of the 2009 International 8 of 30 Energy Conservation Code, as amended. Controls and other snowmelt system parameters apply. DELETE THIS SECTION 2.?? Section 202 The total RREMP payment option is the total sum of exterior energy use of sections 201.1, 201.2 and 201.3. Section 301 ON-SITE RENEWABLE CREDITS Section 301.1 Photovoltaic Systems — On-site renewable credit shall be calculated . ' : 4 $4,250 per 1 kilowatt of the system design. Solar electric (photovoltaic) systems • to the electric grid, are eligible for on-site renewable credit. Systems must be site•, ie -d and installed for solar electric panels to supply at least 90% of rated capacity of - •t . led KW. System designer/installer must be certified by certified by COSEIA • o olar Energy Industries Association) or NABCEP, (North American Board of Cert ed g 'ractitioners). Section 301.2 Solar Hot Water - On-site renewable credit shall : .Iculated as $224.65 $121.25 per 1 square foot of the system design. The size •f - .r hot ater systems is limited to 500 square feet of collector area. [AH: The 121.25 re is . - cost / ft2 to install SHW. We had discussed with the BOCC some `de-rate' to or the lower system energy applicability for most system as well as lower reliabili - . y a de-rate?1 Section 301.3 Ground Source Heat Pump - On-site ne able credit shall be calculated as $6.84 per 100,000 BTU per year of the sy- em design $1,400 per 10,000 Btu's of installed GSHP capacity. In order to use a GSHP • •n-site renewable credit the GSHP system must supply at least 20% of the peak load f4 eating the house and all the exterior energy uses. jAH: Given the significantly to :• -• (this is roughly a 25% credit against the upgrade cost), I suggest removing t • 1°o d 00% of exterior requirements.] agree Each ground source heat pump system . •e tes -d and balanced and the design engineer shall certify in writing that it meets a design •- ficient of performance of 3.0 inclusive of source pump power. OP The ground •op1 y' - must be designed by a CGD (Certified GeoExchange Designer certified bye • • '.tion of Energy Engineers) or a professional engineer with IGSHPA (Internation G . -d Source Heat Pump Association). The mechanical system must be installed • a c 'feed IGSHPA contractor. - ion ' I The total RREMP on-site renewable credit is the total sum of sections 301.1, ! d 301.3. PUBLIC DOMAIN SOFTWARE Section 401 A free calculation program known as RREMP 2009 shall be made available to the public. 9 of 30 EXAMPLE CALCULATION FOR RESIDENTIAL RENEWABLE ENERGY MITIGATION PROGRAM UPDATE Snowmelt Example (Snowmelt requested 800 sq. ft.) $34.00*800/ .91 (efficiency rating of boiler) = $29,890.11 RREMP payment option for exterior energy use will be $29,890.11 ON-SITE RENEWABLE CREDITS 96 square feet of solar hot water panels*$224.65 - $121.25 'per square foot= $21,566.24 RREMP payment option will be $8,323.87 OR 4.8 KW photovoltaic system *$6,241.20 $4,250 per , :watt= $29,957.76 RREMP payment option will be $0 lb "Appendix B" (added) 1111 "Commercial Renewable Energy Mitigati ' o_ram" SECTION 101 SCOPE AND A► TION Section 101.1 Scope. Commercial s ' melt, outside pool, or outside spa(ADD HEAT TAPE? It is listed in it's own section below, but we are proposing pulling it into the same fee/offset model... ) systems andet.� ent may be installed only if the supplemental energy meets the requirements of t e mme al Renewable Energy Mitigation Program (CREMP) Appendix B. This applies to al tallations for which an application for a permit or renewal of an existing permit is filed or is by law required to be filed with or without an associated Building Permit that include syste s des 'ibed in section 101.1. Sectio 10 ' ommercial Renewable Energy Mitigation Program (CREMP) Option — Exterior energy us, for commercial snowmelt systems, outdoor spas, and outdoor pools are calculated as directed by Section 201. Section 101.2.1. R-10 insulation shall be installed under all areas to be snow melted. R-5 insulation may be used when the insulation extends up the sides of the slab. [Similar to residential, consider removing the edge exception] Section 101.3 On-site Renewable Credits Option — Renewable credit options are calculated as directed by Section 301. 10 of 30 I SECTION 102 PAYMENT OPTION The CREMP payment option is the difference in energy use calculated in section 202 and on-site renewable credits calculated in section 302 and shall be paid at the time of issuance of the building permit. The payment, if any, is based on the amount of energy required, expressed as dollars per square foot, to operate the exterior energy use systems. No payment shall be made to an applicant that exceeds the energy use with on-site renewable credits. All monie o lected pursuant to this section shall be recorded in a separate fund and shall be spent in acc. • • ith a joint resolution by the Aspen City Council and Pitkin County Board of County Co . m' sio ers. SECTION 103 CREDITS FOR ON-SITE RENEWABLE ENERGY This CREMP payment option is voluntary. Applicants interested in : terio •n- gy use systems can alternatively choose to produce on-site renewable energ i ectio 301) with solar photovoltaics and/or solar hot water or micro-hydro. The energy effici- -chnology of ground source heat pumps is also permitted for supplemental on-site -ne . . SECTION 104 PRE-EXISTING SYSTEMS Pre-existing snowmelt, pools or spas Installed prior t:Asp P. kin Energy Conservation Code (APECC adopted in 1995) which are being replaced overhauled or renovated qualify for exterior energy credit. This credit can only be applied owards an installation of exterior energy on the same parcel. The calculation of the credi s '.u11 be based on section 301. The maximum allowable replacement credit shall be 60,. quare feet of snowmelt (or 240,000,000 BTU's). The replacement credit may be ap. -. . ,th; exterior energy consumption. Systems installed after the adoption of APECC ' o.. permit approval are not eligible for replacement credit and are subject to all a. . 1 .le fe:". [AH: Similar edits to residential section.] SECTION 105 - COMMERCIAL 4 'PAIRS Repairs to buildi I c• pels, systems, or equipment which do not increase their pre-existing energy consunip i. 4-"a •of comply with CREMP. SECTION 21 iSy'IOR ENERGY USE CALCULATIONS Se ?. 20 owmelt energy consumption shall be calculated as a CREMP payment option at .' .. '1.71 per square foot divided by the boiler efficiency (AFUE) with the following excep 'o.. Section 201.2 Outdoor pool energy use shall be calculated as a CREMP payment option at $170.00 $348.76 per square foot divided by the boiler efficiency (AFUE). Section 201.3 Spa energy use shall be calculated as a CREMP payment option at $176.00 $357.03 per square foot divided by the boiler efficiency (AFUE). Package spas with not more than 64 square feet of water surface area are exempt. 11 of 30 Section 202 The total CREMP payment option is the total sum of exterior energy use of sections 201.1, 201.2 and 201.3. Section 301 ON-SITE RENEWABLE CREDITS Section 301.1 Photovoltaic Systems — On-site renewable credit shall be calculated as $6,241.20 $4,250 per 1 kilowatt of the system design. Solar electric (photovoltaic) systems :• o the electric grid are eligible for on-site renewable credit. Systems must be sited, • ' ,nd installed for solar electric panels to supply at least 90% of rated capacity of the in a ed . System designer/installer must be certified by COSEIA (Colorado Solar Ens. : I stries Association) or NABCEP (North American Board of Certified Energy Practitio - Section 301.2 Solar Hot Water- On-site renewable credit shall be ca A late• as $224.65 $112.25 per 1 square foot of the system design. The size of solar hot waters stems is limited to 500 square feet of collector area. Section 301.3 Ground Source Heat Pump - On-site renewab : ' e• ' shall be calculated as $644 per 100,000 BTU per year of the system design $1,400 - ' 000 Btu's of installed GSHP capacity. In order to use a GSHP for on-site renewable -• - GSHP system must supply at least 20% of the peak load for heating the building as 1 t® erior energy uses. Each ground source heat pump system shall be tested and balanced a m d e design engineer shall certify in writing that it meets a design coefficient of performance of 3.0 exclusive of source pump power. [AH: remove reference to system sizing qua ' ier'.' The ground loop system must be d;.' r CGD (Certified GeoExchange Designer certified by the Association of Energy E P_i ee or professional engineer with IGSHPA (International Ground Source Heat Pump • ',tion). ' he mechanical system must be installed by a certified IGSHPA contractor. Section 302 The total C rAv ' on-site renewable credit is the total sum of sections 301.1, 301.2 and 301.3. • PUBLIC DO A \ •FTWARE Se • A 0 ' ee calculation program known as CREMP 2009 shall be made available to the pu EXAMPLE CALCULATION FOR COMMERCIAL RENEWABLE ENERGY MITIGATION PROGRAM Snowmelt area 1200 sq. ft. $60.00*1,200/.92 efficienc ratio_ of boiler) = $78,260.87 12 of 30 Pool area 700 sq. ft. $170.00*700/.92(efficiency rating of boiler)= $119000.00 Spa area 80 sq. ft. $176.00*80/.92(efficiency rating of boiler)=$15,304.35 CREMP payment option for exterior energy use will be $222,913.04. ON-SITE RENEWABLE CREDITS 448 square feet of solar hot water panels*$224.65121.25 per square fo = $100,612.1154.432 20 KW photovoltaic system *$6,211.201,250.00 per kilowa•w ,. .!!85,000 I CREMP payment option will be ',' NEED TO UPDATE EXAMPLE CALC Add Section 403.81. to Section 403.8 Snow melt systems c► ro 1. Electric roof and gutter deicing systems sh. c tomatic controls capable of shutting off the system when outdoor temperature is abo 4 • degrees F and below 25 degrees F, or which limit the use of the system to dayli:o t hours by means of a programmable timer. [AH: Another good system control is a mois P ' ensor. List this as an option? Consider requiring the temp limit+ either moisture • 'mer.� 2. Hydronic roof and gu -r de : . stems shall be considered snowmelt systems and shall comply with Appendix - iden .1 Renewable Energy Mitigation Program" of the 2009 International Energy Conservation c •:e, as amended. SECTION 501 GovernmORenewable Energy Mitigation Program (GREMP) Local, State anal •- 2vernment Buildings and Structures may be exempted from mitigation payments and o et Fined previously in this code for a percentage of the requested snowmelt when there i dstrated risk to public safety related to snow and ice removal. The o‘i ems and any related documentation will be reviwedreviewed and evaluated to dete - e potential exemption. A percentage of exempted area will be determined and any remaining equested snowmelt will need to be paid for or mitigated in the typical format. Upon receominendationrecommendation by the Chief Building Official, a formal request will be compiled by the applicant and presented to the Board of County Commissioners for final approval at a regularly scheduled meeting. 501.1 An application for review and approval would include the following: 1. Demonstration and declaration that typical mitigation methods were researched and proven not feasible. 13 of 30 2. Demonstration that the public service being service provided by the entity applying offsets the energy consumption being requested in this application including any cumulative offset exemption requests for REMP mitigation. 3. Demonstration of safety risk to the General Public if exterior snowmelt is not installed including: a. Providing the ratio of total paved area vs. Snowmelted paveme, b. Illustrating that the project minimizes the total amount of exterior t .y used; and c. The installation of snowmelt only in critical public safety ar. 4. Demonstration that BTU's saved through other means (ex'•°ing ip ent upgrades, envelope improvements, or other energy saving measur- nsla, to mitigation BTU's for snowmelt credit. Examples include: a. -Hybrids, EV use on site b. Wind Powser ? c. Hydro-Electric d. Waste Oil Boilers e. Pellet Boilers—This is CO2 offs• i th th.n an energy offset... still applies? 5. Demonstration that offsite mitigatio ga& . yes have been considered at other offsite locations within Pitkin Co W5P he installation of typical mitigation methods. a. Typical Gro • o e 5 eat Pump, Solar, or PhotoVvoltaic methods that are not feasibl= • 'te co d be installed at a more feasible location 6. Other creative or innovat ve alternatives proposed by the applicant. Upon review and ec• ntion by the Chief Building Official, areas associated with these buildings or sty '• .re critical to pedestrian ingress, egress, or life safety may, at the discretion of the oa County Commissioners,be exempted from REMP payments for all or a portion of t•' ar owmelted. (Or . ' '-I u t); prior code Title VII 19-4); Chapter 11.32 repealed/replaced Ord. 01-10; C , - .32 amended(part) Ord. 030-10) Chapter 11.32 amended(part) Ord. 016-13 14 of 30 I 11.32: INTERNATIONAL ENERGY CONSERVATION CODE Section 101.1 Jurisdiction, Pitkin County Section 107.1 Fees is hereby amended and shall read as follows: "A permit shall not be valid until all fees as prescribed in the Pitkin County Community Development Fee Ordinance that is in effect at the time of permit submittal are paid in full, nor shall an amendment to the permit be released until the additional fees, if any, have been paid." Section 107.5 Refunds is hereby amended and shall read as follows: The building official shall authorize the refund for the full amount of any fee paid which was erroneously paid or collected. Not more than 80% of a permit fee paid may be refunded when no work has been done under a permit issued in accordance with this code. The building official shall not authorize refunding any fee paid except when submitted on a written application filed by the original permittee not later than six months after the date of payment. Refunds may be approved for up to 80% of a fee paid for REMP. No refund will be approved when requested more than 180 days after the Certificate of Occupancy or Letter of Completion is issued. Section 109 Board of Appeals 109.1 General is deleted in its entirety and shall read as follows: Appeals shall be in accordance with Pitkin County Code Title 11, Chapter 11.04, Section 112.1. Section 110 Liability to read as follows: The Building Official or his authorized representative charged with the enforcement of this code, acting in good faith and without malice in the discharge of his duties, shall not thereby render himself personally liable for any damage that may accrue to persons or property as a result of any act or omission in the discharge of his duties. This code shall not be construed to relieve or lessen the responsibility of any person owning, operating or controlling any building or structure for any damage to persons or property caused by defects on or in such premises, nor shall the code enforcement agency, any employee thereof, or Pitkin County be held as assuming any such responsibility or liability by reason of the adoption of this code or by the exercise of inspections authorized and carried out thereunder, or by the issuance of any permits or certificates issued pursuant to this code. Section 301 Climate Zones shall be deleted in its entirety and shall read as follows: "The City of Aspen, Colorado and Pitkin County, Colorado shall use Climate Zone 7 in determining the applicable requirements from Chapters 4 and 5". Section 402.4.2 Air sealing and insulation is hereby amended and shall read as follows: 15 of 30 I "For Remodels and Additions: Building envelope air tightness and insulation installation shall be demonstrated to comply with the testing option of section 402.4.241.2 at a rate of seven air changes per hour at 50 pascals of pressure when tested with a blower door. Visual inspection can be substituted when testing is determined by the code official as not being a feasible option.".- Section 402.4.3 Fireplaces is hereby amended and shall read as follows: New wood-burning fireplaces and gas log fireplaces shall have gasketed doors and outdoor combustion air. "Appendix A" "Residential Renewable Energy Mitigation Program" Section 101 SCOPE AND ADMINISTRATION Section 101.1 Scope. Residential snowmelt, outside pool, or outside spa systems and equipment may be installed only if the supplemental energy meets the requirements of the Residential Renewable Energy Mitigation Program (RREMP) Appendix A. This applies to all installations for which an application for a permit or renewal of an existing permit is filed or is by law required to be filed with or without an associated Building Permit that include systems described in section 101.1. Section 101.2 Residential Renewable Energy Mitigation Program (RREMP) Option — Exterior energy use for residential snowmelt systems, outdoor spas, and outdoor pools are calculated as directed by Section 201. For the purposes of this document, exterior water features (fountains, reflecting ponds, etc.) shall be considered a"Pool Section 101.2.1. Snowmelt systems requirements: 1. The maximum area of snowmelt is capped at 6,000 square feet per parcel. 2. R-10 insulation shall be installed under all areas to be snowmelted. 3. All snowmelt systems shall employ controls that control slab temperature to a set temperature. 4. No `idling' of slab systems (maintaining a minimum temperature) shall be allowed. 5. Presence of moisture must be detected for slab heating activation. 6. Temperature cutoffs shall be employed to not allow snowmelting below 20F or above 40F. 7. Systems shall employ zoning for different aspects (North, South, East, West etc.) and uses. Section 101.2.2 Roof, gutter and other exterior melting options not defined as snowmelt. 1. Electric roof and gutter deicing systems shall use self-regulating heat tape with maximum peak wattage of l OW per linear foot or square foot. 2. Electric roof and gutter deicing systems shall include automatic controls: 16 of 30 a. Capable of shutting off the system when outdoor temperature is above 40 degrees F and below 25 degrees F. b. AND limit the use of the system to daylight hours by means of a programmable timer OR a gutter mounted moisture sensor c. AND seasonal shutoff mechanism clearly labeled. 3. Hydronic roof and gutter melt systems: Shall be considered snowmelt systems and shall comply with Appendix A "Residential Renewable Energy Mitigation Program" of the 2009 International Energy Conservation Code, as amended. Controls and other snowmelt system parameters apply. Section 101.2.3 Pool requirements: 1. Pool area will include any vertical or horizontal areas associated `spillover' features as calculated area. 2. Pools are required to have R-1 covers installed. Section 101.2.4 Spa requirements: Provide R-12 minimum cover. Section 101.3 On-site Renewable Credits Option — Renewable credit options are calculated as directed by Section 301. Section 102 Payment option. The RREMP payment option is the difference in energy use calculated in section 202 and on-site renewable credits calculated in section 302 and shall be paid at the time of issuance of the building permit. The payment, if any, is based on the amount of energy required, expressed as dollars per square foot, to operate the exterior energy use systems for 20 years. No payment shall be made to an applicant that exceeds the energy use with on-site renewable credits. All monies collected pursuant to this section shall be recorded in a separate fund and shall be spent in accordance with a joint resolution by the Aspen City Council and Pitkin County Board of County Commissioners. Section 103 Credits for on-site renewable energy. This RREMP payment option is voluntary. Applicants interested in exterior energy use systems can alternatively choose to produce on-site renewable energy (Section 301) with solar photovoltaics and/or solar hot water or micro-hydro, or reduce the energy to be offset via reductions in the proposed size of applicable systems. The energy efficient technology of ground source heat pumps is also permitted for supplemental on- site energy. SECTION 104 PRE-EXISTING SYSTEMS Pre-existing snowmelt, pools or spas installed 20 years prior to the date of permit submission will be eligible for a credit towards the calculated REMP fee. This credit will be a pro-rated based upon the portion of 20 years that have passed since original installation. For example, a system installed 12 years prior would be eligible for a credit of 8 of 20, or 8/20 = .4 of the fee as calculated in Section 201. (NOTE: THIS PRO-RATING ADDRESSES FEES, BUT DOES NOT ADDRESS ISSUES SURROUNDING EXISTING SYSTEMS THAT ARE LARGER THAN THE 6,000FT2 MAXIMUM.) 17 of 30 I Section 105 -Residential repairs. Repairs to building components, systems, or equipment which do not increase their pre-existing energy consumption need not comply with RREMP. All replacement mechanical equipment shall be Energy Star©rated. Section 106 Residential Renewable Energy Mitigation Program(RREMP) for houses 5,000 square feet and more. A new residence 5,000 sq ft or more in area(as defined by the building code), or a residence receiving an addition which brings the area of the residence to 5,000 sq ft or more, is required to offset a portion of its fossil fuel energy consumption through the use of on- site renewable energy or through a fee payment to REMP. Section 201 EXTERIOR ENERGY USE CALCULATIONS Section 201.1 Snowmelt energy consumption shall be calculated as a RREMP payment option at $68.97 per square foot divided by the boiler efficiency (AFUE). Section 201.2 Outdoor pool energy use shall be calculated as a RREMP payment option at $275.89 per square foot divided by the boiler efficiency (AFUE). Section 201.3 Spa energy use shall be calculated as a RREMP payment option at $4-7-6700 $357.03 per square foot divided by the boiler efficiency (AFUE). Package spas not more than 64 square feet are exempt. No more than one spa per property shall be exempt. Section 201.4 Roof, gutter and other exterior melting: 1. Electric systems: RREMP payment option at $5.87 per watt of installed electric heating element. Note this fee is per watt, not linear foot. Using lower wattage heat tape will lower the energy use and therefore the required mitigation. 2. Hydronic systems: Shall be considered snowmelt systems and shall comply with Appendix A"Residential Renewable Energy Mitigation Program" of the 2009 International Energy Conservation Code, as amended. Controls and other snowmelt system parameters apply. Section 202 The total RREMP payment option is the total sum of exterior energy use of sections 201.1, 201.2 and 201.3. Section 301 ON-SITE RENEWABLE CREDITS Section 301.1 Photovoltaic Systems — On-site renewable credit shall be calculated as $4,250 per 1 kilowatt of the system design. Solar electric (photovoltaic) systems tied to the electric grid, are eligible for on-site renewable credit. Systems must be sited, oriented and installed for solar electric panels to supply at least 90% of rated capacity of the installed KW. System designer/installer must be certified by NABCEP, (North American Board of Certified Energy Practitioners). 18 of 30 I Section 301.2 Solar Hot Water - On-site renewable credit shall be calculated as $224.65 $112.25 per 1 square foot of the system design. The size of solar hot water systems is limited to 500 square feet of collector area. Section 301.3 Ground Source Heat Pump - On-site renewable credit shall be calculated as $1,400 per 10,000 Btu's of installed GSHP capacity. Each ground source heat pump system shall be tested and balanced and the design engineer shall certify in writing that it meets a design coefficient of performance of 3.0 inclusive of ground loop field pump power. The credit will be increased based upon the ration of equipment COP over the base requirement of 3. Example: A system with a COP of 3.5 would qualify for $1,400 x (3.5/3) = $1,633 per 10,000 Btu's of system capacity. The ground loop system must be designed by a CGD (Certified GeoExchange Designer certified by the Association of Energy Engineers) or a professional engineer with IGSHPA (International Ground Source Heat Pump Association). The mechanical system must be installed by a certified IGSHPA contractor. Section 302 The total RREMP on-site renewable credit is the total sum of sections 301.1, 301.2 and 301.3. PUBLIC DOMAIN SOFTWARE Section 401 A free calculation program known as RREMP 20XX shall be made available to the public. EXAMPLE CALCULATION FOR RESIDENTIAL RENEWABLE ENERGY MITIGATION PROGRAM ISnowmelt Example Snowmelt of 800 sq. ft. $68.97*600/ .93 (efficiency rating of boiler) = $44,497.77 Gutter melt system of 300W $5.87*300 = $1,761 RREMP payment option for exterior energy use will be $44,497.77 ON-SITE RENEWABLE CREDITS 450 square feet of solar hot water panels *$112.25 per square foot= $50,512.50 OR 10.5 KW photovoltaic system *$4,250 per kilowatt= $44,625 RREMP payment option will be $0.00 or$1,643.71 19 of 30 "Appendix B" (added) "Commercial Renewable Energy Mitigation Program" SECTION 101 SCOPE AND ADMINISTRATION Section 101.1 Scope. Commercial snowmelt, roof and gutter melt, outside pool, or outside spa systems and equipment may be installed only if the supplemental energy meets the requirements of the Commercial Renewable Energy Mitigation Program (CREMP) Appendix B. This applies to all installations for which an application for a permit or renewal of an existing permit is filed or is by law required to be filed with or without an associated Building Permit that include systems described in section 101.1. Section 101.2 Commercial Renewable Energy Mitigation Program (CREMP) Option — Exterior energy use for commercial snowmelt systems, outdoor spas, and outdoor pools are calculated as directed by Section 201. For the purposes of this document, exterior water features (fountains, reflecting ponds, etc.) shall be considered a"Pool." Section 101.2.1. Snowmelt systems requirements: 8. The maximum area of snowmelt is capped at 6,000 square feet per parcel. 9. R-10 insulation shall be installed under all areas to be snowmelted. 10. All snowmelt systems shall employ controls that control slab temperature to a set temperature. 11. No `idling' of slab systems (maintaining a minimum temperature) shall be allowed. 12. Presence of moisture must be detected for slab heating activation. 13. Temperature cutoffs shall be employed to not allow snowmelting below 20F or above 40F. 14. Systems shall employ zoning for different aspects (North, South, East, West etc.) and uses. Section 101.2.2 Roof, gutter and other exterior melting options not defined as snowmelt. 4. Electric roof and gutter deicing systems shall use self-regulating heat tape with a maximum peak wattage of l OW per linear foot or square foot. 5. Electric roof and gutter deicing systems shall include automatic controls: a. capable of shutting off the system when outdoor temperature is above 40 degrees F and below 25 degrees F b. AND limit the use of the system to daylight hours by means of a programmable timer OR a gutter mounted moisture sensor c. AND seasonal shutoff mechanism clearly labeled. 6. Hydronic roof and gutter melt systems: Shall be considered snowmelt systems and shall comply with Appendix A "Residential Renewable Energy Mitigation Program" of the 20 of 30 I 2009 International Energy Conservation Code, as amended. Controls and other snowmelt system parameters apply. Section 101.2.3 Pool requirements: 1. Pool area will include any vertical or horizontal areas associated `spillover' features as calculated area. 2. Pools are required to have R-1 covers installed. Section 101.2.4 Spa requirements: Provide R-12 minimum cover. Section 101.3 On-site Renewable Credits Option — Renewable credit options are calculated as directed by Section 301. SECTION 102 PAYMENT OPTION The CREMP payment option is the difference in energy use calculated in section 202 and on-site renewable credits calculated in section 302 and shall be paid at the time of issuance of the building permit. The payment, if any, is based on the amount of energy required, expressed as dollars per square foot, to operate the exterior energy use systems. No payment shall be made to an applicant that exceeds the energy use with on-site renewable credits. All monies collected pursuant to this section shall be recorded in a separate fund and shall be spent in accordance with a joint resolution by the Aspen City Council and Pitkin County Board of County Commissioners. SECTION 103 CREDITS FOR ON-SITE RENEWABLE ENERGY This CREMP payment option is voluntary. Applicants interested in exterior energy use systems can alternatively choose to produce on-site renewable energy (Section 301) with solar photovoltaics and/or solar hot water or micro-hydro. The energy efficient technology of ground source heat pumps is also permitted for supplemental on-site energy. SECTION 104 PRE-EXISTING SYSTEMS Pre-existing snowmelt,pools or spas installed 20 years prior to the date of permit submission will be eligible for a credit towards the calculated REMP fee. This credit will be a pro-rated based upon the portion of 20 years that have passed since original installation. Example: A system installed 12 years prior to permit submittal would be eligible for a credit of 8 of 20, or 8/20= .4, i.e. a credit of 40% of the fee as calculated in Section 201. SECTION 105 - COMMERCIAL REPAIRS Repairs to building components, systems, or equipment which do not increase their pre-existing energy consumption need not comply with CREMP. SECTION 201 EXTERIOR ENERGY USE CALCULATIONS 21 of 30 Section 201.1 Snowmelt energy consumption shall be calculated as a CREMP payment option at $60.00 $121.71 per square foot divided by the boiler efficiency (AFUE) with the following exception: Section 201.2 Outdoor pool energy use shall be calculated as a CREMP payment option at $348.76 per square foot divided by the boiler efficiency (AFUE). Section 201.3 Spa energy use shall be calculated as a CREMP payment option at $357.03 per square foot divided by the boiler efficiency (AFUE). Package spas with not more than 64 square feet of water surface area are exempt. No more than one spa per property shall be exempt. Section 202 The total CREMP payment option is the total sum of exterior energy use of sections 201.1, 201.2 and 201.3. Section 301 ON-SITE RENEWABLE CREDITS Section 301.1 Photovoltaic Systems — On-site renewable credit shall be calculated as $6,241.20 $4,250 per 1 kilowatt of the system design. Solar electric (photovoltaic) systems tied to the electric grid are eligible for on-site renewable credit. Systems must be sited, oriented and installed for solar electric panels to supply at least 90% of rated capacity of the installed KW. System designer/installer must be certified by COSEIA (Colorado Solar Energy Industries Association) or NABCEP (North American Board of Certified Energy Practitioners). Section 301.2 Solar Hot Water - On-site renewable credit shall be calculated as $112.25 per 1 square foot of the system design. The size of solar hot water systems is limited to 500 square feet of collector area. Section 301.3 Ground Source Heat Pump - On-site renewable credit shall be calculated as $1,400 per 10,000 Btu's of installed GSHP capacity. Each ground source heat pump system shall be tested and balanced and the design engineer shall certify in writing that it meets a design coefficient of performance of 3.0 inclusive of ground loop field pump power. The credit will be increased based upon the ration of equipment COP over the base requirement of 3. Example: A system with a COP of 3.5 would qualify for $1,400 x (3.5/3) = $1,633 per 10,000 Btu's of system capacity. The ground loop system must be designed by a CGD (Certified GeoExchange Designer certified by the Association of Energy Engineers) or a professional engineer with IGSHPA (International Ground Source Heat Pump Association). The mechanical system must be installed by a certified IGSHPA contractor. Section 302 The total CREMP on-site renewable credit is the total sum of sections 301.1, 301.2 and 301.3. PUBLIC DOMAIN SOFTWARE 22 of 30 Section 401 A free calculation program known as CREMP 20XX shall be made available to the public. NOTE: The C and R REMP `Programs' are really one spreadsheet. Alternate language? EXAMPLE CALCULATION FOR COMMERCIAL RENEWABLE ENERGY MITIGATION PROGRAM Snowmelt area 1200 sq. ft. $121.71*1,200/.96 (efficiency rating of boiler) = $155,380.39 Pool area 700 sq. ft. $348.76*700/.96(efficien ating of boiler)= $249,112.38 Spa area 80 sq. ft. $357.03*80/.96(efficiency rating of boiler)=$29,752.37 CREMP payment option for exterior energy use will be $436,594.39 ON-SITE RENEWABLE CREDITS 500 square feet of solar hot water panels*$121.25 per square foot= $56,125 35 KW photovoltaic system *$4,250.00 per kilowatt= $148,750.00 CREMP payment option will be $204,875.00 SECTION 501 Governmental Renewable Energy Mitigation Program(GREMP) Local, State and Federal Government Buildings and Structures may be exempted from mitigation payments and offsets defined previously in this code for a percentage of the requested snowmelt when there is a demonstrated risk to public safety related to snow and ice removal. The following items and any related documentation will be reviewed and evaluated to determine the potential exemption. A percentage of exempted area will be determined and any remaining requested snowmelt will need to be paid for or mitigated in the typical format. Upon recommendation by the Chief Building Official, a formal request will be compiled by the applicant and presented to the Board of County Commissioners for final approval at a regularly scheduled meeting. 501.1 An application for review and approval would include the following: 1. Demonstration and declaration that typical mitigation methods were researched and proven not feasible. 2. Demonstration that the public service being service provided by the entity applying offsets the energy consumption being requested in this application including any cumulative offset exemption requests for REMP mitigation. 23 of 30 3. Demonstration of safety risk to the General Public if exterior snowmelt is not installed including: a. Providing the ratio of total paved area vs. Snowmelted pavement b. Illustrating that the project minimizes the total amount of exterior energy used; and c. The installation of snowmelt only in critical public safety areas. 4. Demonstration that BTU's saved through other means (existing equipment upgrades, envelope improvements, or other energy saving measures)translate to mitigation BTU's for snowmelt credit. Examples include: a. Hybrids, EV use on site b. Wind Power-2 c. Hydro-Electric d. Waste Oil Boilers e_Pellet Boilers e: This is CO2 offset rather than an energy offset... still applies? 5. Demonstration that offsite mitigation alternatives have been considered at other offsite locations within Pitkin County for the installation of typical mitigation methods. a. Typical Ground Source Heat Pump, Solar, or Photovoltaic methods that are not feasible on site could be installed at a more feasible location 6. Other creative or innovative alternatives proposed by the applicant. Upon review and recommendation by the Chief Building Official, areas associated with these buildings or structures that are critical to pedestrian ingress, egress, or life safety may, at the discretion of the Board of County Commissioners,be exempted from REMP payments for all or a portion of the area snowmelted. (Ord. 99-61 (part); prior code Title VII§9-4); Chapter 11.32 repealed/replaced Ord. 01-10; Chapter 11.32 amended(part) Ord. 030-10) Chapter 11.32 amended(part) Ord. 016-13 24 of 30 , AVM- çntlq wino s v i 'u saw yw 1.w•/v.wt M.Ile r fir. - . MUMMY.NOVEYSER 25,ties Well known for green building Wodehouse Builders recycle techniues and cycledqmate al�nr new onstruc• house to benefit charities tion, Wodehouse Builders is also taking steps to save our planet's resources by assuming an active role In the demolition and recycling of , existing structures. 1 t 4 We recently "deconstructed" an - '- =-e= - • • - entire home on Red Mountain _ i where thetaii buildin f''` __ `i "The main thing we want • �_ materials to stress is there is an - _ - �� are being alternative to throwing �, ,� , complete!} everything in the ', -- - -- dumpster and taking it to _ recycled. the landfill" . � _"s -�`` The profits _- _ _ ~_ Michael Aiwa. ; "- - from the ,� .,. ..... .,,.,...,.,,.r r -- f ` - sale of - - ='� materials "T - • - are benefitting Challenge Aspen, an � c‘ \�, adaptive skier program. Blechman deconstruction in Red Mountain. GREEN BUILDING AWARDS Our efforts in the Asps Dia ilers Amnia Sports D Intl field of Green Building November 25, 1999 The Powell Residence have been recognized Builders Recycle House to in Telluride's east end was both nationally and locally. We have been Benefit Charities selected as Home of the featured recently in the Year in October 1998, as following media articles: Telluride Magazine well as winning the AI A's Summer 1999 199E Architect's Choice Is Your !)ream House Award, as featured in the Tellun de Style Magazine Denver Post. Winter 1999/00 Green? (p. 42) Build Your Dream Richard House and Help Save Colorado Homes& lifestyles In addition, World (p. 82) - Wodehouse made presen- theMagoilne tations at the Energy March/April 1999 Efficient Building Asso- Custom Home Magazine Colorado's Best in ciation (EEBA) national National Association Residential Architecture convention, both in of Home Builders' (COBRA) October 1998 in Wash- November '99, Pacesetter Award-winning Johnson ington, DC and again in Award fur Innovation in Residence near Telluride October, '99 iiittaltimore, The Construction and Demolition Debris Diversion Status and Opportunities in Pitkin County Cathleen Hall, Pitkin County Solid Waste Manager Executive Summary Construction and demolition debris (C&D) are recognized as one of the largest components of the County's waste stream. In 2015 C&D comprised 55% of the waste entering the Pitkin County Landfill. Avoidance of landfilling C&D provides a greater degree of environmental protection, a smarter use of natural resources, energy savings, savings of landfill air space, and a net decrease in greenhouse gas emissions. This report summarizes the benefits of diverting C&D to assess the potential for recycling and waste diversion in Pitkin County. The report also summarizes potential opportunities for reuse based on resources and facilities located at the Pitkin County Solid Waste Center (SWC) and throughout the Roaring Fork Valley. Pitkin County Landfill Construction and Demolition Debris/Waste Composition The Pitkin County Landfill has an estimated 14 years of landfill capacity remaining. In 2015 the landfill accepted 41,318 tons or 137,272 cubic yards of C&D material, which makes up 55% of the incoming buried waste stream. C&D primarily consists of drywall, lumber, plywood, fixtures, metal framing, and cardboard, plastic sheeting, roofing shingles, concrete, and windows. From 2006 through 2015, 80% of the C&D was ground and used for alternative daily cover in the landfill working face. Building contractors could claim a beneficial reuse credit for ground C&D because of its use as alternative daily cover on the landfill. In December 2015, operations changed and the C&D was no longer ground for use as alternative daily cover; it is now compacted into the landfill. Due to potential air quality issues and the expense of operating a C&D grinder, Pitkin County opted to cease grinding operations and chose to purchase a larger landfill compactor to achieve equal or higher compaction rates for the waste. C&D material for disposal closely follows the economy and building permits. As the economy improves, the number of building and demo permits increases, thus increasing the amount of C&D waste generated. The following table shows the amount of C&D material from 2008 through 2015. 26 of 30 Cubic Yards of C&D 2008-2015 200,000 180,000 160,000 140,000 120,000 100,000 80,000 60,000 40,000 20,000 2008 2009 2010 2011 2012 2013 2014 2015 After 2008, the county saw a slight dip in the amount C&D that was generated. 2014 showed an all-time peak in incoming C&D material, which amounted to 63% of the waste stream. Staff are projecting a decline in the amount of C&D, which closely mimics the drop in construction and demolition permits issued, over the next few years. Even with the decrease in the amount of C&D generated, there is still an abnormally high amount of C&D waste to manage. The County is looking into ways to divert and recycle a bulk of this waste. Existing County Programs for C&D Diversion Pitkin County has a 40%waste diversion rate, as referenced in the 2016 Roaring Fork Valley Waste Diversion Plan. Phase I of the waste diversion study looked at traditional municipal solid waste and recycling; C&D was not studied in detail. The SWC has little in the ways of diversion and recycling opportunities for C&D waste. The SWC currently houses the "Drop and Swap" area where usable materials and furniture can be diverted for no charge. However, the Drop and Swap facility is uncovered and space is limited. The SWC also diverts scrap metal for recycling. However, in many cases, once the C&D arrives at the SWC as trash, it is unrecoverable for any reuse or recycling opportunities. The Roaring Fork Valley is also home to a robust Habitat for Humanity program, with two warehouse facilities in Basalt and Glenwood Springs. Habitat offers the best reuse opportunity of materials and furnishings salvaged from remodels and demolitions. However, the owner and the contractors must make a concerted effort to capture and properly handle those materials before they are sent to the landfill. 27 of 30 During Phase II of the Roaring Fork Valley Waste Diversion Plan, staff will research recycling opportunities that are economically viable for our region. One such solution is to study the effectiveness of adding ground drywall material into the composting stream. Markets for used lumber and other building materials will be researched. Future C&D Waste Diversion Planning Efforts Pitkin County is taking active steps to improve C&D waste diversion efforts. Planning is underway to study more closely the C&D waste stream through a visual waste sort. The composition of the County's C&D waste will be included in Phase II of the Roaring Fork Waste Diversion Plan. In addition to the composition of the C&D waste stream, recommendations for diversion and recycling will be included. Staff also intend to propose an expanded, covered Drop and Swap area in the 2017 budget. The proposed expanded facility will include a covered pole barn type structure, lighting, and staffing to manage the facility. In addition, inventory will be managed and scrutinized for value and reuse opportunity. Staff are researching facility designs and costs to make the most out of the available area and space. The expanded Drop and Swap will be closely modeled after Habitat for Humanity, Monterey, California's Last Chance Mercantile, and Boulder, Colorado's Charm facility. These reuse facilities mimic retail store set ups, and are operated based on profits generated. Materials that come in to the Drop and Swap will be hard goods such as furniture, fixtures, doors, lumber, tile, flooring, reusable construction materials. The expanded Drop and Swap will not accept upholstered furniture or mattresses, electronics, or clothing/textiles. Materials will be inspected by a staff person and managed through an inventory system. Summary The Pitkin County Landfill sees an abnormally high amount of C&D entering the waste stream, this has to do with our unique tourist economy, home values, and limited vacant land for building. Residents, mostly second homeowners, choose to demo existing structures and rebuild. There is very little incentive to encourage homeowners and businesses to de-construct structures to divert waste for reuse opportunities. Through a combination of diversion incentives and regulations, improving diversion facilities at the SWC, and partnerships with local reuse organizations, the County would likely see a decrease in the amount of C&D material from being buried in the landfill. With a limited lifespan reaming for the Pitkin County Landfill it is imperative that all waste reduction and diversion opportunities be implemented. 28 of 30 • I APPENDIX RB SOLAR-READY PROVISIONS-DETACHED ONE- AND TWO- :. ,. , FAMILY DWELLINGS, MULTIPLE SINGLE-FAMILY DWELLINGS (TOWNHOUSES) Ems; ,, ; (The provisions contained in this appendix are not mandatory unless specifically referenced in the adopting ordinance.) G ;` SECTION RB101 RB103.6 Interconnection pathway. Construction docu- - SCOPE tents shall indicate pathways for routing of conduit or • RB101.1 General. These provisions shall be applicable for plumbing from the solar-ready zone to the electrical service new construction where solar-ready provisions are required. panel or service hot water system. RB103.7 Electrical service reserved space.The main elec- trical service panel shall have a reserved space to allow SECTION RB102 installatiorijof a dual pole circuit breaker for future solar elec- , GENERAL DEFINITION tric installation and shall be labeled"For Future Solar Elec- f :;; :SOLAR-READY ZONE.A section or sections of the roof or tie! The reserved space shall be positioned at the opposite building overhang designated and reserved for the future (load)end from the input feeder location or main circuit loca- installation of a solar photovoltaic or solar thermal system. tion. RB103.8 Construction documentation certificate. A per- SECTION RB103 manent certificate, indicating the solar-ready zone and other SOLAR-READY ZONE requirements of this section, shall be posted near the electri- cal distribution panel,water heater or other conspicuous loca- RB103.1 General.New detached one-and two-family dwell- tion by the builder or registered design professional. ' ings,and multiple single-family dwellings(townhouses)with not less than 600 square feet(55.74 m2) of roof area oriented . : between 110 degrees and 270 degrees of true north shall com- '; ply with Sections RB 103.2 through RB103.8. Exceptions: • 1. New residential buildings with a permanently installed on-site renewable energy system. 2. A building with a solar-ready zone that is shaded for more than 70 percent of daylight hours annually. RB103.2 Construction document requirements for solar- .ready zone.Construction documents shall indicate the solar- ; ,:ready zone. RB103.3 Solar-ready zone area.The total solar-ready zone area shall be not less than 300 square feet(27.87 m2)exclu- sive of mandatory access or set back areas as required by the International Fire Code. New multiple single-family dwell- sings (townhouses)three stories or less in height above grade plane and with a total floor area less than or equal to 2,000 ': square feet (185.8 m2) per dwelling shall have a solar-ready zone area of not less than 150 square feet (13.94 m2). The I solar-ready zone shall be composed of areas not less than 5v. I .• '; "feet (1524 mm) m width and not Less than 80 square feet ' � q �,; (7.44 m2)exclusive of access or set back areas as required by the International Fire Code. 1 RB103.4 Obstructions.Solar-ready zones shall be free from :obstructions, including but not limited to vents, chimneys, ;and roof-mounted equipment. .RB103.5 Roof load documentation. The structural design loads for roof dead load and roof live load shall be clearly indicated on the construction documents. 29 of_30 ( .2015 INTERNATIONAL ENERGY CONSERVATION CODE® R-51 N1101.14 Certificate(Mandatory).A permanent certificate shall be completed by the builder or registered design professional and posted on a wall in the space where the furnace is located, a utility room or an approved location inside the building. Where located on an electrical panel,the certificate shall not cover or obstruct the visibility of the circuit directory label,service disconnect label or other required labels.The certificate shall list the predominant F-values of insulation installed in or on ceiling/roof,walls,foundation (slab,basement wall, crawl space wall and/or floor)and ducts outside conditioned spaces; U-factors for fenestration and the solar heat gain coefficient(SHGC)of fenestration,and the results from any required duct system and building envelope air leakage testing done on the building.Where there is more than one value for each component,the certificate shall list the value covering the largest area. The certificate shall list the types and efficiencies of heating,cooling and service water heating equipment.Where a gas-fired unvent- ed room heater,electric furnace,or baseboard electric heater is installed in the residence,the certificate shall List"gas-fired unvented room heater,""electric furnace"or"baseboard electric heater,"as appropriate.An efficiency shall not be listed for gas-fired unvented room heaters,electric furnaces or electric baseboard heaters.Where.;photovoltaic systems are present,the.certificate shall;.indicate the number:of panels;the nameplate rating of.the:systeirt(kW) and.the anticipated:average annual output(kWh)of the systeiri Addj new sections to.incorporate the existing.'BuildSmart deconstruction,..constructiion,jobsite waste reduction and recy- cling and indoor iwdter conservation.requirements. N1101.15 Deconstruction(Mandatory) NJ.1Q1151 Deconstruction.All;eztistiztg buildings aiid portions.thereofrequirring removaaf;building.materials:must be:de- constivcted as defined in this.chapter Derriolition:is not perrrittted . . . ......... N11.O1.1t5 2 Penalty Buildings.that are demolished:or pal tially;demolished rrather than deconstructed will;.:at.the discretion of the Building Official,be issued a Stop Work notice fora period note ceeding:30 days. 1101°153'Docuntentati[on.of:Intent to Deconstruct.Documentation o€intentto:deconstructconsistingofa;deconstruction plan,°a:written description of deconstruction:work,or the County Leeonstruction Checklist must,be provided at building permit`application. e Th documeritation'of intent to deconstruct must include:the name Of the Deconstruction Contractor;a .. ..... .. ...... list..ofthe!materials to e recovered donated,or reused,end the destination of the iiiaterials.Tlie:'documentation must include both Nonstructural:Deconstruction and Structural°Deconstruction Iteins.:whic}.iiiust be donated,.sold;or re-used include: cabinets i:din.ens onal lumber,flooring;and solid core:doors. r N1.10,11.15 4.•Veriftcation of deconstruction of a structure.:The completion of deconstruction as approved on the decon- struction.plan must be verified by the Building Division:The owner or deconstruction contractor shall provide written verifi- cation of deconstruction by Means of receipts or a written:log;maintained by the..homeowner or general contractor,which in- cliides the..volume or weight of materials and the destination where.thek...............................Division office. Verification riu:st be received prior to scheduling tar:rough.inspecti ons. NI101.I6 Construction Jobsite.Waste Reduction and Recycling.(Mandatory).All construction jobsite waste must be recycled including.wood;.scrap metal;eardbe ark and concrete.Labeled.containers must be provided at the construction-site.for use in captur- ingrecyclabTe material.:ssi.mixed.load contairier.may be•used if that container is being sent:to a waste/recycling centerthat will.verify the weight.of recycled material recoveredfroin that mixed::load N11:01 16.1.•Documentation of Intent;to'Recycle:Documentation of intent,to recycle:which consists of a recycling plan;a written description ofrecycling activity,or the submittal of the County:Recycling Checklist must be provided at building perniit application.The documentation innst clearly show howthe requirements of Section 1101.15 will be inet and must specifythe locations.o f recycling containers and the destination:where:material willbe recycled. N1:1011....M.Z1YetifientintE.Tieidinspection willbe inade'by the:Boulder County Building Division;during the construction process to assure that recycling containers have been placed on-site.Prior to the final inspection,docu n,m tnentatioust be provided to the Building:Division:office by the owner or waste/recycling contractor indicating the weight:or volume,of Mate- . .. rials diverted from the waste stream.Materials that must be recycled include:appliances,concrete,metalss,cardboard,and wood(except pressure treated or painted wood),and thermostats and other devices containing mercury.Other materials which are accepted by the waste/recycling contractor must also be recycled. N1101..17-.indeor..water conservation(Mandatory).,New and replacement.bathroom sink faucets,shower heads,toilets,and:urina[ Must be labeled as.meeting EPA Water Sense(www epagovlWaterSensel}:enterfa; 2015 Amendments to Boulder County Building Code•Effective January 1,2016 56 30 of 30