HomeMy WebLinkAboutpitkin.eh.264321302008 (2015)1!11 SK Permit #: 0030.2015.POWT %,idSITE WASTEWATER TREAT --._NT SYSTEM (OWTS) CONSTRUCTION PERMIT 76 Service Center Rd Aspen, CO • 81611 Phone: 970.920.5070 Fax: 970.920.5374 Parcel ID #: 2643-213-02-008 Permit Issued: ®NEW []REPAIR ❑REMODEL/ADDITION []TANK ONLY []FIELD ONLY []AMENDMENT Owner(s): Tad and Kathreen Hundertmark Property Address: 295 Upper Ranch Rd Legal Description: Lot 4 Block 2 Filing 2 Brush Creek Village Size of Lot: 2.054 Acres Detached Accessory Unit: ❑YES ONO Size of Building: 1400 ft' Size of Accessory Unit: This system is designed to serve 4 bedrooms. The existing hous,;-_ ,. Designed By: Phone #: Fax #: All Service Septic Project #: _ Mailing Address: Perc Rate: 0.15 LTAR Email Address: C1110 Dated: January 29, 2015 Profile Hole Depth: T Depth to Groundwater or Bedrock: ➢ 7' Minimum Tank Capacity: 1250 gallons Minimum Absorption Area: 3000 ft2 Permit Conditions: This OWTS Construction Permit is approved on the condition of compliance with the engineer design as submitted with the application and the specifications cited above. Changes must be approved by this Department and the engineer prior to construction. This permit is for a new OWTS to serve the existing 3 -bedroom residence. The system has been designed to serve 4 - bedrooms to accommodate a future bedroom addition. Sewage will flow via gravity to a 1250 -gallon two-compartment septic tank with an effluent filter on the outlet tee. Effluent will then flow via gravity to an Orenco AX20RT treatment system with a pump. Effluent will then be dosed through an Automatic Distribution Valve (ADV) and to a 5 zone NDDS soil treatment area (STA). Each STA bed will have four 2" diameter distribution laterals 50 -feet long and 2 feet -on -center apart. Inspection ports will be installed at the end of one lateral in each zone. The STA shall be a minimum of 10 feet to the property line, 20 feet to the residence, and 100 feet to any well. This Permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an "as-buitP letter to this Department within 30 days of the final inspection, unless a longer period of time has been agreed upon, in writing. This Department must also be called for the final inspection with a minimum of 48 -hours notice. Minimum horizontal distances between components of the system and physical features shall conform to the requirements of the Pitkin County OWTS Regulation. This Permit is conditioned upon the property owner(s) providing for regular inspection, cleaning, and maintenance of the system by qualified personnel, in accordance with the manufacturer's recommendations and the requirements of the Pitkin County OWTS Regulation. Issuance of this OWTS Construction Permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail. Issuance of this permit does not imply compliance with Pitkin County building and/or land use regulations, nor guarantee issuance of building and/or land use permits. THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN COUNTY OWTS REGULATION, INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE. Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Pitkin County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built' drawing must be submitted and approved by EH before final approval of the system will be issued. Issued By: Kurt Dahl, REHS Date: 09/16115 Expires: 09116/16 License #: Reactivation Authorized by: G �n Final Approval Issued By Date- Date: t New Expiration Date: "E] Fee IS 0030,2015 ,pow i 17 uNSITE WASTEWATER TREATMEL. JYSTEM (OWTS) A EH/NR (��f(/ CONSTRUCTION PERMIT APPLICATION l V 76 Service Center Rd - Aspen, CO • 81611 Phone: 970.920.5070 Fax: 970.920.5374 Parcel IO# (available from the Pitkin County Assessor's Office 970-9205160 or at www.pitkinassessor.ora): / L / A6 - 3,R i - oo(Y Purpose of Permit: ❑AEW ❑ REPAIR DUE TO FAILURE ❑ REMODELIADDITION ❑ TANK ONLY ❑ FIELD ONLY Cost of Syst m Repair or Remodel/Addition (approximate): Business one: 11 33 Property Address, Email Address: C.oN 'i PW L , Lot:Block Filing: Bt 44T Subdivision: 1� C v , ZuFae— Building Permit # (if a plicable): Property Owner s)': Email Address: Owner's Mailing Address: City, State, Lp: jn� -- AS W Home Phone: _ I Business Phone: 'Contact inrorma#on must he Provided for the owner signing this application. Pd ry Contact PersonlApplicaant (If not owner): Company: Contact/Applicant Melling Address: 96 City State, Zip: C O Or, Cell Phone: Business one: 11 33 Fax Number. a -2 �A Email Address: C.oN 'i PW L , Building Permit # (if a plicable): Lot Size (in acres): '2•DS Size of Building (square feet): „ -4RLD c3:'3' Number of Potential Bedrooms: Detached Accessory Unit? ❑ YES 5(NO Size of Accessory Unit (square feel): Number of Polel edrooms In or Fixture Ust for the Accessory Unit: Water Source: ❑ PRIVATE WELL ❑ SURFACE WATER ❑ SPRING .COMMUNITY/PUBLIC WATER SYSTEM Name of Community/Public Water System (if applicable): PLEASE READ BEFORE SIGNING: I certify that the above Information Is complete and accurate and that I have provided complete and accurate information in all of the documents Included In my application package. I acknowledge that EHINR may revoke any permit I am Issued if my application is found to contain any Inaccurate, false, or misleading Information. I understand that no construction may be undertaken on an OWTS until an OWTS Construction Permit is Issued. 33 Four Wheel DriveRd CO1 Carbondale, CO 81673 970.309.5259 SERVICE April 3, 2016 Tad Hundertmark aradgulat7a hotmail.com Onsite Wastewater Treatment System (OWTS) Installation Observations 295 Upper Ranch Road Pitkin County, Colorado OWTS Construction Permit 0030.2015.POWT Tad, Project No. C1110 ALL SERVICE septic, LLC observed the installation of the onsite wastewater treatment system (OWTS) on October 7, 2015 and January 4, 2016 for the subject property. Sacred Ground Excavation installed the system. The existing septic tanks were removed and the existing seepage pit was pumped and the void filled with gravel. The system installation included a new 1250 -gallon, two-compartment Valley Precast concrete septic tank with an Orenco® Biotube Effluent filter on the outlet tee. An Orenco® AdvanTex AX20RT Treatment System with an Orenco® PF3005 pump was also installed. The control panel for the pump was placed within line of sight of the septic tank and AX20RT unit. The effluent filter located in the second compartment of the 1250 -gallon septic tank must be cleaned annually, or as needed. Effluent is pumped through a 1.25 -inch diameter transport line to a model 4605 Automatic Distributing Valve (ADV), which is insulated and is accessible from grade. We opted not to install an air relief valve to minimize the chance of freezing. Effluent exits the ADV with 1.25 -inch diameter pipes into five distribution boxes, all accessible from grade. Each distribution box feeds 2 -inch diameter pipes going to three NDDS sections, each with four 2 -inch distribution laterals, each 50 feet long, connected with a 2 - inch diameter level manifold. Laterals have '/<-inch orifice holes at 6 o'clock, 8 -inches on center. Each section is stepped down the hillside. Inspection ports installed at the end of each zone. Valley Precast performed start-up on the AdvanTex AX20RT unit and they currently hold the maintenance contract on this system. A maintenance contract on the AdvanTex system is required by the manufacturer and by Pitkin County for proper long term functioning of the system. The OWTS was generally installed according to specifications. This observation is not a guarantee of workmanship and/or parts and materials. ALL SERVICE septic, LLC should be notified if changes are made to the OWTS in the future. Any additional OWTS construction must be according to the county regulations. LIMITS: Observations are limited to components that are visible at the time of the inspection. The installer must have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. The quality of the installation is dependent of the expertise of the installer, soil type, and weather conditions. Please call with questions. Sincerely, ALL SERVICE septic, LLC Nt'LL (., 08-�&&s Carla Ostberg, MPH, RENS Reviewed A RichardH. New pipe and clean out tapped to existing line from house 1250 -gallon, two-compartment septic tank �Y' OUL . Inlet tee X Outlet tee with filter �e- 19 1% Q� RI®flr4nRiae.�r �I / C� T (Pk\;, Y A (Pk\;, Y N 0' 10' 20' Scale: 1'=20'-0' C� O RECOR® THE LOCATION OF EXISTING AND PROPOSED IMPROVEMENTS SHOWN ARE NOT THE RESULT OF A PROPERTY SURVEY. THE LOCATIONS ARE APPROXIMATE. ��` Hundertmark Residence Date: 04103116 33 Four Wheel Drive Road N Carbandala, Colorado 81623 295 Upper Ranch Read ' 970.309.5259 Pitkin County, Cabrado pesi9ned By. CBO record I N SfBV C eahone da@allservi=eptIc.com Reviewed By. RHP Project Number. C7110 Drawn By ANG Sheet 1 of 1 Do Your Part, Be S imak: The Do's and Don'ts of Your Septic System Learn these simple steps to protect your home, health, environment and property value: sephcsmarf �, LLSFme�nmtJOmM.m •gmer Do: • Have your system inspected (in general) every three years by a licensed contractor and have the tank pumped, when necessary, generally every three to five years. Dont: • Pour cooking grease or oil down the sink or toilet. • Rinse coffee grounds into the sink. • Pour household chemicals down the sink or flush them. Don't: • Hush non -degradable products a chemicals, such as feminine hygiene products, condoms, dental floss, diapers, cigarette butts, cat litter, paper towels, pharmaceuticals. Don't: • Park or drive on your drainfield. The weight can damage the drain lines. • Plant trees or shrubs too close to your drainfield, roots can grow into your system and clog it. Don't • Concentrate your water use by using your dishwasher, shower, washing machine, and toilet at the same time. All that extra water can really strain your septic system. Do: • Eliminate or limit the use of a garbage disposal. • Properly dispose of coffee grounds E food. • Put grease in a container to harden before discarding in the trash. Do: • Dispose of these items in the trash can! Do: • Consult a septic service professional to advise you of the proper distance for planting trees and shrubs, depending on your septic tank location. Do: • Stagger the use of water -generating appliances. This can be helpful especially H your system has not been pumped in a long time. • Become more water efficient by fixing plumbing leaks and consider installing bathroom and kitchen faucet aerators and water -efficient products. 33 Four wheel Drive CO1 Carbondale, CO 81623 970-3095259 ,6N11, January 29, 2015 Tad Hundertmark c/o Dana Carpenter Daybreak Construction Specialties, Inc. PO Box 582 Glenwood Springs, CO 81601 davbreakconstructfon anhotmail.com Project No. C1110 Subsurface Investigation and Onsite Wastewater Treatment System (OWTS) Design 3 -Bedroom Residence (4 -Bedroom OWTS Design) 295 Upper Ranch Road Pitkin County, Colorado Tad, ALL SERVICE septic, LLC performed a subsurface investigation and completed an onsite wastewater treatment system (OWTS) design for the subject residence. The property is located outside of Aspen, in an area where OWTSs are necessary. The legal description of the property is Block 2, Lot 4, Filing 2, Brush Creek Village Subdivision. SITE CONDITIONS A 3 -bedroom single-family residence presently exists and a detached garage with plumbing is proposed. The existing sheds in the area of the proposed garage will be abandoned. The existing residence is utilizing an existing OWTS which will be properly abandoned. The existing OWTS is documented under Pitkin County OWTS Use Permit 0033.2014.powu and requires replacement of the existing no later than July 16, 2015. The subdivision is served by a community water system. No wells exist within 100 -feet of the proposed soil treatment area (STA) or within 50 -feet of the proposed septic tank(s)- The proposed STA location has approximately a twenty-five percent slope to the northeast across the proposed STA. Vegetation over the proposed STA consists of sage, scrub oak, and other native grasses. No potential future land use changes are planned for the property. A future bedroom is contemplated over the proposed garage and therefore, the OWTS design will be able to accommodate 4 bedrooms. SUBSURFACE The subsurface was investigated on November 11, 2014 by digging three soil profile test pit excavations (Test Pits) ranging from 5 to 7 -feet in depth. A visual and tactile analysis of the soils was performed on the Test Pits at approximately 2 to 3 -feet below grade. A Soils Log is provided (W5.0). The materials encountered in the Test Pit #1 consisted of dark brown, moist topsoil to 12 -inches, underlain Page 2 by medium brown to tan, moist, clay with blocky structure shape, strong structure grade, and extremely firm consistence to a maximum depth explored of 7 -feet. No bedrock or groundwater was encountered. The material encountered in Test Pits #2 and #3 was consistent with findings in Test Pit #1, with a maximum depth explored of 5 -feet. No bedrock or groundwater was encountered. The soil was classified as Soil Type 4, clay (with blocky structure and strong structure grade). For sizing purposes, a long term acceptance rate (LTAR) of 0.15 gallons per square foot will be used to design the OWTS, in accordance with Soil Type 4A outlined in Table 6.28-7 presented in the Pitkin County On -Site Wastewater Treatment System Regulations. Test Pits observed November 11, 2014 Test Pit #1 Test Pit #2 Test Pit #3 Page 5 LIMITS: The design is based on information submitted. If soil conditions encountered are different from conditions described in report, ALL SERVICE septic, LLC should be notified. All OWTS construction must be according to the county regulations. Requirements not specified in this report must follow applicable county regulations. The installer should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. Please call with questions. Sincerely, ALL SERVICE septic, LLC Otv_t ( 0_S-I-6(.1k's Carla Ostberg, MPH, REHS Reviewed By: Richard H. Petz, Liability Clause: Under no circumstances whatsoever shall the #ability of ALL SERVICE septic, LLC, in conneabon with any contrw4 directly or Indirectly, exceed the total amount paid by the client to ALL SERVICE septic, LLC for the services and/or goods which are the subject of the contract In connection with which the #ability arises. Page 3 DESIGN SPECIFICATIONS The existing OWTS must be properly abandoned. The septic tank will be removed, and the existing seepage pit pumped and filled with soil and rock so a void no longer exists. The OWiS design is based on 4 -bedrooms. A design flow of 600 GPD will be used. A Non -Pressurized Drip Dispersal System (NDDS) has been designed in accordance with criteria outlined in Colorado Professionals in Onsite Wastewater (CPOM Guidelines for the Design and Installation of NDDS, Revised December 11, 2014. Design Calculations: Wastewater Flow = Q = 75 gaUday x 2 people/bedroom x 4 Bedrooms = 600 gaUday Q 1 LTAR = 60010.15 = 4000 SF x 1.5 Size Adjustment Factor = 6000 SF 6000 SF 12 = 3000 lineal feet of non -pressure drip dispersal pipe The system installation will include a new 1250 -gallon, two-compartment Valley Precast concrete septic tank with an Orenco® Biotube Effluent filter on the outlet tee, followed by an Orencov AX20RT Treatment System' with an OrencoO PF3005 pump. An equivalent pump able to achieve 10 gallons per minute and 35 feet of total dynamic head may be considered. The NDDS system has been designed to completely fill 25% - 50% of the distribution laterals in each zone each pump cycle; therefore, the floats should be set for a dose volume of approximately 90 gallons (see calculations below). The control panel for the pumps must be placed within line of sight of the septic tank and AX20RT unit Effluent filter(s) must be cleaned annually, or as needed. Pipe calculations are as follows: 1.25 -inch diameter pipe from AX20RT Unit to ADV = 9.3 gallons (drain back) 1.25 -inch diameter pipe from ADV to farthest D -box = 2.7 gallons .174 gallons x 25 feettlateral x 4 laterals x 3 sections = 52.5 gallons .174 gallons x 8 feet/ manifold x 3 manifolds = 4.2 gallons 9.3 gal + 2.7 gal + 52.5 gal +4.2 gal = 68.7 gallons — 9.3 gallons drain back = 59A gallons Minimum 60 gallons/dose Set floats to 90 gallons per dose Effluent will be pumped through a 1.254nch diameter transport line to a Model 4605 Automatic Distributing Valve (ADV), which must remain accessible from grade. An air relief valve must be placed at the high point on the 1.254nch diameter line from the AX20RT Unit to the ADV. Effluent will exit the ADV with 1.254nch diameter pipes into five distribution boxes, all accessible from grade and set level with a baffle or angled pipe at the inlet. Each distribution box will feed 2 -inch diameter pipes going to three NDDS sections, each with four 24nch distribution laterals 50 -feet long connected with a 2 -inch diameter level manifold. Laterals must be installed with a trencher, with each line 2 -feet on center. Laterals must have '/.-inch orifice holes at 6 o'clock, 8 -inches on center. Dispersal laterals must be Installed a minimum 12 -inches and maximum 30 -inches deep. Each section may be stepped down the hillside. An inspection port must be installed at the end of at least one lateral in each zone. ' Please note the specification sheets W4.0 and W5.0 do not minor exact design specifications. The 1250 - gallon septic tank must include an effluent fitter on the outlet tee, and the RT Unit must be preceded by a 1250 -gallon septic tank, not a 1000 -gallon tank. l 1 y Page 4 The component manufacturers are typical of applications used by contractors and engineers in this area. Alternatives may be considered or recommended by contacting our office. Construction must be according to Pitkin County Onsite Wastewater Treatment System Regulations, the OWTS Construction Permit provided by PMdn County Environmental Health Department, and this design. REVEGETATION An adequate layer of good quality topsoil capable of supporting revegetaticn shall be placed over the entire disturbed are of the OWTS installation. A mixture of native grass seed that has good soil stabilizing characteristics (but without taproots), provides a maximum transpiration rate, and competes well with successional species. No trees or shrubs, or any vegetation requiring regular irritation shall be plated over the area. Until vegetation is reestablished, erosion and sediment control measures shall be implemented and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation cover. OPERATION INFORMATION AND MAINTENANCE The property owner shall be responsible for the operation and maintenance of each OWTS servicing the property. The property owner is responsible for maintaining service contracts for manufactured units, alternating STAB, and any other components needing maintenance. This technology requires a maintenance contract with qualified personnel be maintained, and maintenance performed per manufacturer recommendations. A renewable permit may be required per county regulations. Geo -fabrics or plastics should not be used over the STA No heavy equipment, machinery, or materials should be placed on backfilled STA. Livestock should not graze on the STA Plumbing fixtures should be checked to ensure that no additional water is being discharged to OWES. For example, a running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a STA. The homeowner should pump the septic tank every two years, or as needed gauged by measurement of solids in the tank. Garbage disposal use should be minimized, and non -biodegradable materials should not be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS. Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste only. ADDITIONAL CONSTRUCTION NOTES If design includes a pump, air release valves and weep holes must be installed to allow pump lines to drain to minimae risk of freezing. The pump shall have an audible and visual alar notification in the event of excessively high water conditions and shall be connected to a control breaker separate from the high water alar breaker and from any other control system circuits. The pump system shall have a switch so the pump can be manually operated. Excavation equipment must not drive in excavation of the STA due to the potential to compact soil. Extensions should be placed on all septic tank components to allow access to them from existing grade. Backfill over the STA must be uniform and granular with no material greater than minus 3 -inch. INSTALLATION OBSERVATIONS ALL SERVICE septic, LLC must view the OWTS during construction. The OWTS observation should be performed before backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing siphons, and other plumbing, as applicable, must also be observed. ALL SERVICE septic, LLC should be notified 48 hours in advance to observe the installation. Pump Selection for a Non -Pressurized System - Single Family Residence Project Hundertmark Residence 1295 Upper Ranch Road, Pitkn County, CO Parameters Discharge Assembly Sim 1.25 !"dies Transport Length Before Valois 120 feet Transport Pipe Claw 40 feet Transport Line Sim 1.25 inches DisnbuBng Vis he Mo dA 4805 :eel Transport Length After Velw 35 feel Transport Pipe Ge» 40 Transport Pipe Sim 1.25 Inches Max Elevation Lift 28 rest Design Flaw Rete 10 Will Row Metz None inches Add-on'Fdcdon Lomas 0 feet Calculations Transport Velodly Before Vere 22 fps Tomspad VeloatYAfw Velve 2.2 fps Frictional Head Losses Low through Discharge 0.7 feet Lou in Transport Before Vele 1.7 feet Lose through Valva 3.2 feet Low In Transport after Veba 05 feel Low through Flovaneier 0.0 :eel 'Add-on' Pomo" Losses 00 at Pipe Volumes Vol of Transport Line Before Velee 9,3 gals Vol of Transport Line AllerValve 23 gala Minimum Pump Requirements Design Flow Rate 10.0 ppm Total Dynamic Head 34.2 feet ar.vav erlenra onn Net Discharge (gpm) Pumpoeta PF3005 High Head E18ueel Pump 30 GPM, 12HP 11 512M 10 BO12,200V 3000Hz P173007 High Head Effluent Pump 30 GPM, 314HP 230V 108OH; 200MBOV 3080Hz PF3010 High Heed Effluent Pump 30 GPM, 1HP 230V 10801-1; 2001460V 3000Hx PF3015 High Head Effluent Pump 30 GPM, 1-112HP 230V 1080H; 20012301460V 308OHz 5ys:em Curs Pump Cuae. Pump Optimal Range_ Operaung Point Design Paint 1 Th IN Pitkin County Environmental Health Department e Onsite Wastewater Treatment System (OWTS) USE PERMIT Co ILI INT Permitfor Continued Use of an Existing DINTS 76 Service Center Road, Aspen, CO 81611 Phone: 970-920-5070 Fax: 970-920-5077 www.aspenpitkin.com/EHNR Parcel ID #: 2465-141-02-016 OWTS Use Permit #: I 0033.2014.POWU Date Issued: 08/14/2014 Issued By: Kurt Dahl Expiration Date: 08/14/2015 Owner(s): Robert Mcgill Krueger Property Address: 1295 Upper Ranch Rd Legal Description: I Lot 4 Block 2 Filing 2 Licensed Inspector: I Carla Ostberg Inspection Date(s): July 16, 2014 SYSTEM INFORMATION Components Type Capacity/Size Primary Treatment Unit Likely a single -compartment tank 750 gallons ? Secondary Treatment Unit Absorption Area Concrete block Seepage Pit 13 feet deep Other System Components OWTS Use Status: ® in use at the time of the inspection. Eliot in use at the time of the inspection.* •lithe OWrSwasnot 1n use at the time of the lnspectlan, it Is recommended that the system be re-evaluated when it is rn use far a more accurate evaluation of the system. System Records: Permit #: N/A Date of Issuance: N/A Date of Final Approval: N/A # of Bedrooms or fixtures served by OWTS: 3 bedrooms Operational Status: The OWTS system appears to be a 750 gallon single compartment tank with a 13 -foot deep, concrete block dry well. The system does not meet the minimum Regulations and must be replaced. Since the buyers have indicated they intend to remodel within 1 year (see letter on file), the OWTS may be used for 1 year from the date of the approval of this permit. After one year, the existing OwTS must be abandoned and a new system meeting the minimum requirements of the Pitkin County OWTS Regulations installed. A new construction permit will be required and is administered through this office. Inspector Recommendations: Replace system. Department Recommendations: Limit water usage. Iswunce ofthB OW73 Use Permdisbwedsolelyan themndldansobservedandrepartedby the hupectorto the Depart enton the dote ofthehupecdan(s) and on Depmbnentrecontsat MedmeofpermlWng. lhetuummOfMtrpn itcfu snotmnsdWten guarantee, wanamy, arrePn',m atlm bythe Deportment that thesystem will operate Propedyor willnotfodarthat thesystem wglnathesublecrtofuture enfarcemeataahrn to ca ectad mplla»tmndldona EWmotedmpadtyofehesystemhosbeennstedontheperaritmdweremmmadthatyaumunttormd/ormeterwoWr to Preventwe andpassible failure. *SUBSURFACE DRIP ect Air Valve Description The single effect air vlave is designed to extract and push NM the air inside the piping network It allows for major air ventilation at pump startup. Features Designed to be easily disassembled for cleaning. The large clear passageway allows lots of air to How in and out easily. The elbow cap design is ideal for directing wastewater/air spray. With the internal weight removed, these airvcnts can easily be used as a flush port. Part No. APVSSE•100 APVSSE•200 L3lCt 1" 2^ Max Pressure 80 psi/185 ft. 80 psi/185 ft. Max Temp 140 of 140 of Height 8.0" Specification The Single Effect Air Valve shall provide instant on - continuous air relief. The body and base shall be made of strengthened nylon with glass fibre. The internal weght shall be made of molded plastic and shall be removable for easy cleaning. The air vacuum breaker shall be part number APVSSE-100 or APVSSE-200 as supplied by Geoflow, Inc Pmdu¢ShMS-?O1I tiN2lccS1n1WEfitt[(W) 121121 indd Geoflow, Inc. Tel 415.92760001800.828.3388 Fax 415927.0120 www.geoflow.corn &UBSU, RFACE DRI' e1Sef Vale Description Air release occurs when air escape the system at startup and vacuum relief allows air to enter during shutdown. The air vent vacuum breakers are installed at the highest points in the drip Geld to keep soil from being sucked into the emitters due to back siphoning and back pressure. This is an absolute necessity with underground drip systems. They are also used for proper drainage of the supply and return manifolds. Use one on the high point of the supply manifold and one on the high point of the return manifold and any high points of the system. Features Geoflow's new kinetic air vacuum breakers have a twist off cap that is easy to take apart for cleaning. The large clear passageway allows lots of air to flow in and out easily. The elbow cap design is ideal for directing wastewater spray, directing spray downward. With the ball removed, these airvents can easily be used as a flush port. art No. APVBK75L APVBK100L Act TA l- ax Pressure 80 psi/185 G 80 psi/185 it ax Temp 140 of 140 of eight 5" 5.5" eight 1 oz. 1.2 oz. Available in drip packages or sold separately. Specification The Air Vacuum Breaker shall provide instant and continuous vacuum relief and non -continuous air relief Both the body and the ball shall be made of molded plastic The ball shall be removable for easy cleaning. The au vacuum breaker shall be part number APVBK75L or APVBK100L as supplied by Geoflow, Inc Pmdua Shmu 2011 Am%'-t%awumltelicf(j0 11 HaS.indd Geoflow, Inc. Tel 415.927.60001800.828.3388 Twist 0 cap Ball lei Seal Air and Vacuum Flow Rate (P -Si) fft37m-,n 1 -471 -235 ;m'tmin.) -800 -400 UPDATED MODEL ! o.e 0.4 -0.2 fi.d 0 215 471 706 0 400 807 12DO Firm. Rate Fax 415927.0120 www.geofiow.com 0591SURFACE DRIP600,01" acuum Relie4all UPDATED Description Air release occurs when air escape the system at startup and vacuum relief allows air to enter during shutdown- The air vent vacuum breakers are installed at the highest points in the drip field to keep soil from being sucked into the emitters due to back siphoning and back pressure. This is an absolute necessity with underground drip systems. They are also used for proper drainage of the supply and return manifolds. Use one on the high point of the supply manifold and one on the high point of the return manifold and any high points of the system. Features Geoflow's new kinetic air vacuum breakers have a twist off cap that is easy to take apart for cleaning No need to remove the valve to maintain it The large clear passageway allows lots of air to flow in and out easily. The protected mushroom cap is ideal for wastewater, directing spray downward. Specification The Air Vacuum Breaker bady and ball shall be made of molded plastic The ball shall be removable for easy cleaning. The Air Vacuum Breaker shall be part number APVBK75m or APVBK100m as supplied by Geoflow, Inc Pmdua Shms-2011 AiWMA'u umade.{(u)IM05.imid Air and Vacuum Flow Rabe Ipsi) Part No. APVBK75m APVBK100m Inlet 3/4" 1" Max. Flow Rate 30 gpm Max Pressure 80psi/185 ft. 80psi/185 ft. Max Temp 140 of 140 of Height 5" 5.5" Weight 1 oz. 1.2 oz. 1 -0.2 Specification The Air Vacuum Breaker bady and ball shall be made of molded plastic The ball shall be removable for easy cleaning. The Air Vacuum Breaker shall be part number APVBK75m or APVBK100m as supplied by Geoflow, Inc Pmdua Shms-2011 AiWMA'u umade.{(u)IM05.imid Air and Vacuum Flow Rabe Ipsi) 3.4', ;hsrl a. r o.e a 3.8 0.4 0.2 0 0 -- -2.9 1 -0.2 fit:'m•n 1 -471 23f, 0 233 471 706 (m'tmin.)-800 -40G 0 400 800 12DO Firm- Rnta Geoflow, Inc. Tel 415927-60001800-828.33BB Fax 415927-0120 www.geoflow.com 11 1 1 DESIGN 343EDROOM RESIDENCE t 1 FUTURE BEDROOM (75 GAI/PERSONIDAY x2 PERSONSIBEDROOM x4 BEDROOMS) WASTEWATER FLOW -60O GALLONS TANK- 600 ANK600 x48 HOUR REIFNTIONTNIE=1250 GALLONS USE 1250GALLON, TWOCOMPARTMENTTANK FOLLOWED BYAN ADVANTEKAX 20 RT UNIT SOIL TREATMENT AREA (STAk LONG TERM ACCEPTANCE RATE (LTAR)=0.15 GAV SO FT STA- DALTAR-BOO GAL /0.15 GAL/SO FT=4000 SF 4000 SF K 15 (NODS SIZE ADJUSTMENT FACTOR SORTYPE4A)- MINIMUM 6000 SO FTANO 3000 LINEAL FEET NODS PIPE STING SEEPAGEPITTO PIT #2 BE ABANDONED I \ 0TESTPID®1 PROPOSED I I -+v GARAGE I I PLUMBINGWRH I (SHEDS TO BE DEMOLISHED) I T \ \\ •• I EXISTING \\. \ o•,., i SEPTIC TANK I {f TO REMOVED VED 1 \SID RESIDENCE y / i Lot 4, Block 2 I I 1 II I 1 Y 4� I 7 LEGALDESCRIPTION: r1SITE PLAN BRUSH CREEK VILLAGE FUNS NO.2• BLOCK 2, LOT4 SITUATED IN SECTION 21, TOWNSHIP 9 SOUTH, RANGE 85 WEST OFTHE STH P.M. COUNTY OFPTIION, STATE OF COLORADO DRAWINGS MUST BE USED IN CONJUNCTION WITH DESIGN LETTER DATED 7718/15 3sftndml melwmdRina Hund Residence D otrlsn6II ��etsn Ur R z9suPP�r+xnd,P�,a at Ph= 970.309J4759 �°� PWdn C9tmN.CNaetla BY. CBO W1.0 mm - Pmjw. Nwbw. 01119 PJill �er> Bp_ - _- -- fT`N I P 1P T0' Scab: 1--2P-0' �—\ 'N �� — \\ --I 12POEASCH•40PUMP \\ 1 \ LINETOADVWRHAIR EF VALVE AT HIGH 1 Easeereld, \ \ WT 1 4 WSOR35 SEWER LINE DOUBLE-SWEEP I UT(MN2E \I \\\ \ \\ \\ 2'DNSC-RLIlA18WG I 1 I l L'NENFTER-- \ 4 ..• _. - . i Mp0 0XE6 AX26RT,TREd ENT I NESS\AT 1 \ \ •_; UNfNCO!}I!- � E \ oREcn \ \ \ O -• 'TWac I \ \ ox PARTMEM, 1 \ 1 \ \ 35 '.CQNC SEPIICTANK 177Sd 1PI osOAS E \ \\ \ \\ \ \ \ \ \ \ 1 \ FVC Stand I \ \ I \ 4• D(ASI�R3iSEWER INE 3AmROOM \ \ \ \ RESIDENCE \ \ 1 \ \ \ \ \ \ N I \ 1 \ \ WITH DOLIBLESNEEPL I \ \ CLEANOUT VAIN 2% SLOPE q 1 I \ I TO TANK) ' - \ 1 2• DIA NDDS SYSTEM WITH 1 1 15 SECnONS. PROVIDE 1 INSPSCM ON PO ffr AT END Garepa OF EACH SECTION 1 II .°st N I o v I 01 m II 1]at. 1 I @M222 OWIS 33Fm Wlmd Ddee Roes Hundertmadc Residence Dm 01Q915 Cmboedela, Cola o 0162 eemmm® ,e mpthm PMA CaMfy,Ddmma Deslpaad er raD W2.0 RaNesed ST.. RHP Pm1w Nmobm C1110 Dm B •arvc SIw 12afS roAwvauTmuTwue mnrxeBoueecml xatvaweuALownotTxTal B.'S.ECTKM. mumr F!'BETWEEN LATERALS ;.• uw�iox 30- wr�°w7 emcrnerA .. Aooniwuaacenam xoom SECTION— rj-jVDDS DETAILS %=Wc6TTRlAII 33FuWholDdwRwd Hundertmark Resklenco olrj9tl6 a"' 0'r CsrbmldsJe.CoWM.8lB23 29BLIppwRonchRoW PhMD970-mg.Em PPAh C�ly, Cb,.do md By. CSWO WA3.0 carlacahemicamp6m= wowd ST. r pfujmN,ftw. cille 3, 'q iS ANG !shft 3 ofe SUP -ON PVC I DO NOT GLUE SEWER LINE FINISHED GRADE 4 CLEAN BOX AND COVER BROUGHT TO GRADE CONCRETE LID FINSHED GRADE O O O INLET OUTLETS BAFFLE OR DISTRIBUTION BOX PIPE ANGLED TOWARD BOTTOM tZ� D—BOX DETAIL OF BOX IVIT$ 6r9'P.@ I O - DISTRIBUTING fy FROM EFFLUENT VALVE ASSEMBLY PUMPING SYSTEM 1.25INLETAND OUTLETS 6 ADVO AIL mrmva VI / 1 IANK ObIA1L 6mE 33 F=Wheel Drive Rmd HURderbmrk RBSWBRCB Data 01(2913 .Cdwado31823 JILL.6.1 299 UPW Reece RMWSE DmianW Dr. CBO W9 illPRAM 070.309420 ®eBamvlcasoPUemn PhNn CoM. CcWedo Revkvmd Dr. R 111[11{ PmIeGNumber. C7110 Drawn ,ANC Sheet4 a18 AX20RT Treatment System -Pump Discharge Irmee_.Y�. r.e. Dmim Nd C} e ♦ FIWG.evn I rs 0 .. w.• L .� 1000 gal. Primary Tank - Top View AX20 8D0 gal. Recim Tank - Top View n.a Trsl.c q._d3•nu rem— -r, sr-rw....ol.-r 3MrrIW .-ywr / ATN— fir ��� lY1TW4NYr X rK YOe F b y V� T r- L_I 1000 gal. Pnmary Tank - Side View AX20 800 gal. Recim. Tank - Side View Discharge Chamber - End View /1 TREATMENT UNIT D c4Ppaa W �.% oiemy�YaY. bn 1eeP.r3a arm=ao _ hwaporaW r,.. ar aer rn �...«1 A%�liT 4bd=ta xa.: r.rW h�_� r.. e"..'..... r:.....o Y.." nlear cewN3nwarmp a.a�pae xV r.wdros aa cu"*A srr .e..... �..............:..�.:. ........ NfB7D0IOLL Fx. 40y x. umrtu 33 vfia8 Hundertmrk Residene DM: 9tw15 tt�] 295 Uppw RAu PhwFwn 97W P Cwe y coww w. 0s 9ew By: CBO W5. 5.0 � � ROMmm PMIW NwMer. 01110 of. She 5&6 day vi lapedl KI TESTPITnt DARK BROWN. MOIST TOPSOIL (ROOTZONE) MEDIUMBROWNTOTAN MOIST. CLAY WITH BLOCKY STRUCTURE SHAPE. STRONG BTRUCIUREGRM ONSIS EKTREACLY FlTKM CONBIsiENCE S 1. NO GROUNDWATER ENCOUNTERED BACKHOE TEST PIT 02 DARK BROWN, MOIST TOPSOIL (ROOTZONE) MEDIUM BROWNTOTAN. MOISLCLAYWRHSLOCKY STRUCTURE SKAPE, STRONG BTRUC URE GRADE, AND F](TREMELY FWACON6IBTENCE /15OIL -LOGS %Zjfm cv. TEST PRg3 DARK BROWN, MOIST TOPSOIL (ROOTZONE) MEDIUMBROWNTOTAN. wRoAa MOSR.CAY WRH BLOCIKY STRUCTUREGRAMARD STRUCNRE FIRM CONSISTENCE EXTREMELY FIRM CONSISTENCE 33FWWhed Ddw Head HUndertmark Residence Dela: Dirmla pQw aiei �gCdoo W6.0 =..� dd D®BIredBY•CSO 10( I udaotloeMmeepft Revexed By. RHP'Pmlad Nu . C1110 8r..ANG ShWGdS Brush Creek Metropolitan District 500 Juniper Hill Road, Aspen, CO 81611 970-925-5195 TO: Environmental Health Department FROM: Kevin McClure, Manager Brush Creek Metropolitan District DATE: May 21, 2015 RE: Water Service - Brush Creek Metropolitan District This is to confirm that the Brush Creek Metropolitan District will supply water to the property located at 295 Upper Ranch Road, Brush Creek Village Subdivision, Aspen, Pitkin County, Colorado. If you have any questions, please call me at 970-379-9088, or my email address is kvnmcclure@gmail.com. Except for Soil Type 0, the LTAR may vary, depending on the Soil Type and the Treatment Level of the effluent. You may adjust the LTAR for Soil Types 1-5 by choosing different Treatment Levels, but for Soil Type "0" the LTAR will always be "I" regardless of Treatment Level. Remember that HLT systems are always pressure -dosed, so no additional sizing reductions are Riven for Manufactured or Chamber distribution media for HLT systems. Enter Design Flow (gpd) 600 Enter Number of Bedrooms (including office(s), ADU, etc.) 4 Select LTAR 0.15 Enter Additional Flow in GPD1 0 Select Effluent Application Factor 1 ' 11rJ See Distrbution Media Tabs below for design details TRENCH STA 2001 BED 5 T A FOR TLSw /GRAVEL DISTIRBU11ON MEDIA CLICK HERE to go to/return to this TAB TRENCH STA 4000 BED STA 4800 TRENCH STA 3600 BED STA 4320 1 FOR TLS w /CHAMBER DISTRIBUTION MEDIA CLICK HERE t0 go to/return to this TAB TRENCH STA2800 BED STA 3360 To Calculate STA Reductions for Deep Gravel I CLICK I HERE Ito go to/ return to this TAB To Calculate Distirbution Pipe Volume CLICK HER[ to go to/return to this TAB Enter the Lake Evaporation Rate 42 inches per year ET SYSTEMS 10046 NDDS SYSTEM 3000 House size in sq ft 1600 Flow 75 Minimum Tank Size = YorxIN COUM1T• Pa' -'e I oI, I Kurt Dahl <kurt.dahl@pitkincounty.com> Hundertmark Activity Envelope and Site Plan with Scenic Review 1 message Kurt Dahl <kurt.dahl@pitkincounty.com> To: Lance Clarke <lance.clarke@pitkincounty.com> Tue, Sep 8, 2015 at 10:17 AM Lance, Sorry this is late. I did some investigation on the sizing of the proposed OWTS and given the poor soils and the code will not give a reduction in the field size for this type of system, the sizing cannot be adjusted and they need a large area to accommodate the new field. The proposed system is sized for 4 bedrooms. Please let me know when they have approval of the application and I will issue the permit. Thanks, Kurt Kurt Dahl Pitkin County Environmental Health Manager (970) 920-5438 kurt.dahl@pitkincounty.com 9/8/2015 ATKIN QGu N rfi CVIl NID Pitkin County Environmental "'�alth Department I— 'Onsite Wastewater Treatment Sys:. ,, �Zn (OWTS) USE PERMIT Permit forContinued Use of an Existing OWTS 76 Service Center Road, Aspen, CO 81611 Phone: 970-920-5070 Fax: 970-920-5077 www.aspenpitkin.com/EHNR Parcel ID #: 2465-141-02-016 OWTS Use Permit#: I 0033.2014.POWU Date Issued: 08/14/2014 Issued By: Kurt Dahl Expiration Date: 08/14/2015 Owner(s): I Robert Mcgill Krueger Property Address: 295 Upper Ranch Rd Legal Description: Lot 4 Block 2 Filing 2 Licensed Inspector: Carla Ostb erg Inspection Date(s): July 16, 2014 SYSTEM INFORMATION Components Type Capacity/Size Primary Treatment Unit Likely a single -compartment tank 750 gallons ? Secondary Treatment Unit Absorption Area Concrete block Seepage Pit 13 feet deep Other System Components OWTS Use Status: ® In use at the time of the inspection. ❑Not in use at the time of the inspection.* *If the OWTS was not in use of the time of the inspection, it is recommended that the system be re-evaluated when it is in use for a more accurate System Records: Permit #: N/A Date of Issuance: N/A Date of Final Approval: N/A # of Bedrooms or fixtures served by OWTS: 3 bedrooms Operational Status: The OWTS system appears to be a 750 gallon single compartment tank with a 13 -foot deep, concrete block dry well. The system does not meet the minimum Regulations and must be replaced. Since the buyers have indicated they intend to remodel within 1 year (see letter on file), the OWTS may be used for 1 year from the date of the approval of this permit. After one year, the existing OWTS must be abandoned and a new system meeting the minimum requirements of the Pitkin County OWTS Regulations installed. A new construction permit will be required and is administered through this office. Inspector Recommendations: Replace system. Department Recommendations: Limit water usage. Issuance of this OWTS Use Permit is based solely on the conditions observed and reported by the inspector to the Department on the date of the lnspection(s) and on Department records at the time of permitting. The issuance of this permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail or that the system will not be subject to future enforcement action to correct non-compliant conditions. Estimated capacity of the system has been listed on the permit and we recommend that you monitor and/or meter water use to prevent overuse and possible failure. V� JJ Ntkin County Environmental H( i Department 't'p1 T K t N Onsite Wastewater Treatment System (OWTS) CUti n 1. ti USE PERMIT APPLICATION 76 Service Center Rd Aspen, CO 81611 Website: www.aspenpitkin.com/ehnr/ Annlicatinn fnr rnrttinitnrl I iieo of ftn ntArrQ Primary Contact Person/Appiicant`(if not owner): Da r� Company: IEW ty Assessoes Office- lwww.orBdnassesse from the Phkin or 2 by � 870920 9780 or at orrn): - 213 - v Z 008 Purpose of Use Permit: PROPERTY T1tANSACITON ❑ RENODEUADDITION Cell Phone: q-70 1 Property Address: -3 Fax Num �� ry � 7� J� J Lot: Block: Filing: Subdivision: Indicate Preferred Method of Permit Receipt: Email Pax Z 2— Nor14077MA, Coy Residences: Other Licensed Systems Inspector one Number. CArt7-�-k4 # s of Bedrooms: fixtumsluses: 7 Fax Number. DS 1'3q7&-369-S=r Mailing Addr,e/�' Property Ownar(s)*: \-2-06A- Email Address: tom. > Owners Mailing Address: City, State, Zip: Z9 s vPP.e� CIA ' PLEASE READ BEFORE SIGNING: Home Phone: 7 C1b—m•Contact Business Phone: I certify that the abow IMamatlon is complete and accurate and that I have provltled complete and accurate information In all of the documents Included in my application package. I acknowledge that this department may revoke any 1 am issued H infomaovw� psrmlt my application la found to contain any Primary Contact Person/Appiicant`(if not owner): Da r� Company: Ices, �, S A4 C_ ContaWAppricant Mailing Address: City, ate, Zip: Ui CZ 31C OZ Cell Phone: q-70 1 Business Phone: 970- -3 Fax Num �� ry � 7� J� J ^Email Address: 1� Indicate Preferred Method of Permit Receipt: Email Pax ❑ us Mail Nor14077MA, Coy Licensed Systems Inspector one Number. CArt7-�-k4 Email Address: Fax Number. DS 1'3q7&-369-S=r Mailing Addr,e/�' Ci�ty, S^tat^e, Z�ip: YWJ'2_rti[� Oyu PLEASE READ BEFORE SIGNING: I certify that the abow IMamatlon is complete and accurate and that I have provltled complete and accurate information In all of the documents Included in my application package. I acknowledge that this department may revoke any 1 am issued H Inaccurate, false, or misleading Information. psrmlt my application la found to contain any Signature (Re Please allow 3-5 busing days for processing of Use Permits. i USE ONLY - EH Staff Fee & Receipt is Date: 4100 Sf b 3IN120 1'K IN Pitkin County Environmental alth Department Onsite Wastewater Treatment System (OWTS) CTI NTt USE PERMIT CHECKLIST Permit for Continued Use of an Existing OWTS 76 Service Center Rd Aspen, CO 81611 Phone: 970.920.5070 Fax: 970.920.5374 Website: www.aspenpitkin.com/ehnr Some items listed on this checklist may already exist in the Department files. Please contact this department to collect any necessary documentation, using the parcel ID# to identify the property, priorto scheduling an OWTS Use Permit inspection and/or submitting the OWTS Use Permit application packet. A complete application package must be presented at the time of your pre -application conference for acceptance. To schedule a pre -application conference, please call (970) 920- 5070. PLEASE INITIAL EACH ITEM TO INDICATE COMPLETION Only one copy of each item is necessary. Electronic versions of any or all of the documents identified below may be emailed to ehnr(5)co.pitkin.co.us before the date of the pre -application conference. OWTS Use Permit Application (completed) Site Plan (11x17) Should include general location of each OWTS, buildings, water courses, domestic water source(s), and other pertinent information. Building Floor Plans (11x17) ❑ Current floor plans for a property transaction; or ❑ Proposed floor plans for an addition/remodel that does not increase potential bedroom count or water usage of the structure served by the existing OWTS. Inspection report by a Licensed Systems Inspector Ik'� A list of Licensed Systems Inspectors can be found at www.aspenoitkin com/ehnr An inspection report is good for one year Applicable Fee 1 OWTS Use Permit: $100 Please make checks payable to Pitkin County Environmental Health Department. July 25, 2014 Robert Krueger Go Dana davbreakconstruct(cDhotmail.com Onsite Wastewater Treatment System (OWTS) Use Permit Inspection 295 Upper Ranch Road Pitkin County, Colorado Mr. Krueger, As requested, CBO Inc. performed an Onsite Wastewater Treatment System (OWTS) Use Permit inspection at 295 Upper Ranch Road, Aspen, Colorado on July 16, 2014. No permit and record drawing was available from Pitkin County Environmental Health Department (Parcel ID #2643-213-02-008). The subject OWTS consists of a concrete septic tank followed by a stacked cinder block drywell. The septic tank is likely a single -compartment (although that is not confirmed), 750 -gallon tank (exact capacity not known), with no inlet or outlet tees. According to B&R Septic records, 750 gallons were pumped in March of 2000; 2200 gallons were pumped in 2004 (likely both the tank and drywell), and 500 gallons were pumped in 2011. The septic tank was not pumped as part of this inspection. The septic tank appeared to be holding water at normal levels. Water was run through the system and flow through the septic tank into the drywell appeared to be normal. The stacked cinder block drywell had approximately 4.5 -feet of water in the bottom. Depth from ground level to the bottom of the drywell was 13 -feet. The inlet to the drywell was several feet (exact distance not measured) above the water level in the drywell. At this time, it does not appear that the OWTS poses a risk to public health or the environment. This evaluation is not a guarantee of future system performance. This inspection is good for one year. Typically, repairs would need to be made to this OWTS in order to obtain the required OWTS Use Permit. There is a desire on behalf of the buyer to redevelop the property, which will include replacement of the existing OWTS. Section 6.28.020 B. 2. C of the Pitkin County Onsite Wastewater Treatment Systems Regulation states... "The Department, in its discretion, may waive the requirement for an OWTS use permit where warranted by a particular fact situation (e.g., a buyer agrees to demolish an existing dwelling and abandon the existing OWTS within a defined time period)." The buyer will be requesting a one-year timeframe for continued use of the existing OWTS following transfer of the property in order to obtain the appropriate Pitkin County land use approvals and establish redevelopment plans for the property. The new OWTS will likely be designed by Sopris CBO Inc. 33 Four Wheel Drive Road Carbondale, CO 81623 cell) 970-309-5259 office) 970-704-0484 lei " carla.ostberg(ogmail.com July 25, 2014 Robert Krueger Go Dana davbreakconstruct(cDhotmail.com Onsite Wastewater Treatment System (OWTS) Use Permit Inspection 295 Upper Ranch Road Pitkin County, Colorado Mr. Krueger, As requested, CBO Inc. performed an Onsite Wastewater Treatment System (OWTS) Use Permit inspection at 295 Upper Ranch Road, Aspen, Colorado on July 16, 2014. No permit and record drawing was available from Pitkin County Environmental Health Department (Parcel ID #2643-213-02-008). The subject OWTS consists of a concrete septic tank followed by a stacked cinder block drywell. The septic tank is likely a single -compartment (although that is not confirmed), 750 -gallon tank (exact capacity not known), with no inlet or outlet tees. According to B&R Septic records, 750 gallons were pumped in March of 2000; 2200 gallons were pumped in 2004 (likely both the tank and drywell), and 500 gallons were pumped in 2011. The septic tank was not pumped as part of this inspection. The septic tank appeared to be holding water at normal levels. Water was run through the system and flow through the septic tank into the drywell appeared to be normal. The stacked cinder block drywell had approximately 4.5 -feet of water in the bottom. Depth from ground level to the bottom of the drywell was 13 -feet. The inlet to the drywell was several feet (exact distance not measured) above the water level in the drywell. At this time, it does not appear that the OWTS poses a risk to public health or the environment. This evaluation is not a guarantee of future system performance. This inspection is good for one year. Typically, repairs would need to be made to this OWTS in order to obtain the required OWTS Use Permit. There is a desire on behalf of the buyer to redevelop the property, which will include replacement of the existing OWTS. Section 6.28.020 B. 2. C of the Pitkin County Onsite Wastewater Treatment Systems Regulation states... "The Department, in its discretion, may waive the requirement for an OWTS use permit where warranted by a particular fact situation (e.g., a buyer agrees to demolish an existing dwelling and abandon the existing OWTS within a defined time period)." The buyer will be requesting a one-year timeframe for continued use of the existing OWTS following transfer of the property in order to obtain the appropriate Pitkin County land use approvals and establish redevelopment plans for the property. The new OWTS will likely be designed by Sopris Engineering in conjunction with plans for the new residence(s). The existing OWTS will be abandoned when redevelopment begins. This report should be submitted to the Pitkin County Environmental Health Department, along with the required application and associated paperwork. The buyer must also contact Pitkin County Environmental Health to establish a record of the plan and allowed timeline for continued use of this OWTS. The following links are the required application and application checklist. Application: http: //www. aspenpitkin. com/Portals/0/docs/county/Com %20Dev/E H N R/OWTS%20Use%20Permit% 20Application.pdf Application Checklist Please call with questions. Sincerely, Carla Ostberg, MPH, REHS NAWT Certified Inspector Certification # 11 0441T Exp. 2016 July 16. 2014 Septic tank location / three access pipes to septic tank Three ports of access. Able to see lack of tees on inlet and outlet sides of tank. Not much else able to be viewed. Drywell access well via cinderblock �°'`" I Looking down drywell. Used flashlight to see into drywell. When water was run, could see water entering drywell. Owner's Name: Address: Onsite Wastewater Treatment Systems (OWTS) Use Permit Inspection Form Pitkin County Environmental Health Department 76 Service Center Rd, Aspen, CO 81611 Phone: 970-920-5070 Fax: 970-920-5374 Website: www.aspenpitkin.com/ehnr Inspection form for continued use of an existing OWTS Parcel Number: � (4'�5 a,I ?r-- Ca' — CC V, Inspection Date: -711('110 Inspector's Name: (in tj (r \n�)l , n, Business Name: ORD Inc Phone Number Email: Our La. oca-1L7.P �(,1���i�1G�- -CfyiAi1 Pitkin County Systems Inspector License Number: 1)1 :gill be remitted to Pitkin County Environmental Health Department by i iw IJcc >;_ J Sy;1i•n;s hupccror within 60 days of the inspection regardless of whether the system passes or fails. QUESTIONS FOR PROPERTY OWNER PRIOR TO INSPECTION: Is the home currently occupied? YES NO If NO, how long has the home been vacant? How many bedrooms are in the home? 3 If secondary treatment is used, who is the maintenance provider? N i l) RECORDS: Were system records available from Pitkin County? YES NO If YES: Permit number: Date of Final Approval: # of bedrooms permitted: Was an as -built drawing available? YES NO Is the as -built drawing accurate? YES NO If NO: Complete a drawing of the system on last page of this form as accurately as possible. Any question marked FAIL will require correction before an OWTS Use permit is issued. SITE CONDITIONS: Proper grading, no evidence of erosion? PASS FAIL Improper vegetative cover? NO YES Ory Ihie U Evidence of compaction such as heavy machinery or livestock? N YES Improper discharges such as straight pipes? P FAIL Evidence of high ground water? NO YES Snow cover present? NO YES Page 1 ` C L -15D JO I Zeno Kar: 5 (i_O 20 t Ii 2Lca a( 1 TANK: Timid Evidence of past surfacing? Tank 2 YES Tank 3 If YES, is the pump/dosing siphon functioning properly? Tank capacity FAIL gallons PASS gallons Is the high water alarm working, both visible and audible? gallons Tank material SECONDARY TREATMENT: If YES, is it accessible from grade? YES Is a secondary treatment unit present? YES NO ' ' UNKNOWN n of compartments 7 Does the owner have a current maintenance contract for the unit? YES NO UNKNOWN Maintenance Provider: Phone: Date of last pumping Lids/risers in good condition 11IML PASS FAIL PASS FAIL Risers to grade NO YES NO YES NO Riser height bf Riser condition/watertightness Inlet sanitaryT/baffle PASS FAI PASS FAIL PASS FAIL Outlet sanitary T/baffle PASS %1k" PASS FAIL PASS FAIL Effluent fitter (if part of design) PASS FAIL PASS FAIL N/A PASS FAIL N/A Condition of tank material FAIL PASS FAIL PASS FAIL Tank was pumped for inspection YES N YES NO I YES NO If YES, list the pumping company if NO, when was the last pumping Scum level (1st compartment) inches inches inches Sludge level (1st compartment) inches inches inches Scum level (2nd compartment) inches inches inches Sludge level (2nd compartment) inches inches inches Backflow (if pumped) PASS—SAIL PASS FAIL PASS FAIL Midtank baffle PASS F N/A PASS FAIL N/A PASS FAIL N/A Watertightness P FAIL PASS FAIL PASS FAIL 191 ll rooVcr Lf, -IR i wan iavlk F ctry k1l PUMPS/DOSING SIPHONS: PASS Evidence of past surfacing? Is a pump or dosing siphon present? YES NO'S If YES, is the pump/dosing siphon functioning properly? PASS FAIL Does the pump/wiring/dosing siphon appear to be in good condition? PASS FAIL Is the high water alarm working, both visible and audible? PASS FAIL SECONDARY TREATMENT: If YES, is it accessible from grade? YES Is a secondary treatment unit present? YES NO ' ' UNKNOWN If YES, does the unit appear to be in good working condition? YES NO Does the owner have a current maintenance contract for the unit? YES NO UNKNOWN Maintenance Provider: Phone: If there is no maintenance contract, a contract must be in place prior to occupancy of the home. A copy of the contract must be submitted to Pitkin County Environmental Health Department. ABSORBTION AREA: Effluent surfacing? PASS Evidence of past surfacing? Surface dampness? eN Excessive odors? Field location verified by observation ports or probing: Ports Liquid in observation port? NO If YES, record depth: JJ L}_cjr Wn irLefytW_I� Distribution Box or ADV part of original design? YES If YES, is it accessible from grade? YES Is it level and in good condition? PASS FAIL YES YES YES Probing (- Page 2 j.�Sc��-p YE inches JJ L}_cjr Wn irLefytW_I� �r UNKNOWN FAIL Any problems with the system that were not addressed in the inspection checklist? Please list any recommendations for the continued use of the system: Were any repairs done as a result of this inspection? eo YES If YES, please describe the repairs. To the Pest olff my knowledge and training, the information collected in this inspection is accurate as of ZC_jq' Licensed Systems Inspector Signature: _�.l'd Clearly label any pictures and attach them to this form. Page 3 If no as -built drawings exist for this system or the as -built was inaccurate, please diagram the system as accurately as possible. Be sure to document all system components and the location of any well on the property. Using markers such as comers of the house, exact measurements can be used to triangulate the location ofthe system components for future reference. �IT � � "'V.ERI�Y.AILDIMENSIOIIS WITH MVM-rIH4. 6ASCMCrVj'•, IS -y 1 I 11 -rte II P ,AS'aT 4' G 2." 1GN ONI L.L•116TN TO ---*--. �-III OMPENN_rc, E' F02 SIDIN fa (EMOp ONl ON' 94'SF1��1-1T LEVEL. VE¢IFY ON ':•17 ,Go •2"1-2 .. SC¢GN ¢a F • yl Vo= „p `� �y14�umanSed�and rove-Ment encToP-ograpft-8Ji LY4Y Lot 4, Bloda2 ______ I'll Bnnh Creak A” FINN No.2 _ _ ____ $9WROM W1.424Wn TIP9 SMµ RY 89 We1V ry[ 61a P M, C.11 (R PlilrM. SUIC M CQMIW w t _ ___ - I 1 11' W 11 1 1I 1 1 I I 1 1 1 i 1 1 IF I m t i q _ 11 ` - t j �wwrswr�ioq�womrwusanrowncrrr �Z .}1 o���rFw I, ��`y+ I r �ro.rw.m..emrwn mrynomrcam.aanmSwn 1 1S r�rM.na.rru 111 � 1 a < 1 Mrs i yea �w.,mY ry11 Wa�mr� ` _ww 1'1 V I' nr-1r 1 IYP\\, ,111 I 1 1' mr 11 t q r11 mrta<rru\uvs•rw• I ys ..91C,w Lot 4, Block 2 1'1 t I 1'1 II r . t yK 1 � '1 I n•\•• pM rri w.pOrwuvMt�Oor.iam\q .rrraraao� ' „j. M 4 rn •or'.WrvwrrY�rrorroneere�ruaww•sVr r rr• `��<� A rrn '•1 SurvCo Inc. 1 ak.PIQ W=mll gvs.m cenoRwnn l:ms = ylna le_mw_. �� 1 Of 1 Tad and Kathryn Hundertmark RE: 295 Upper Ranch Road Aspen, CO 81611 To Whom it May Concern: August 8, 2014 On or about August 18, 2014 we will be closing on the purchase of property located at 295 Upper Ranch Road in Aspen, CO. Our intentions are to live in the north part of the present building until we can secure plans and permits required by the county to build a 2000 (+-) sq. foot addition to the south end of the building over what is presently a garage/shop area. We understand all requirements will be established as we go through the permitting process that we will start before the end of this year. Our intentions are to have a building permit in place for us to start the remodel as soon as weather permits in the spring of 2015. At that point we will also have a newly designed OWTS and other details accomplished to complete this project. Sincerely, Tad and,Kathryn Hundertmark Tad Hunpertmark Kathmark 7700 1 7720It It 4 7730 1 + It .��it � `, I tl\ 1, i � � \\\ �I• <t <. 7740 (�} °01'54 c ` ` ��yr tt i `I \` 1 \\` 10' Utility Easement per `\ `\� \\`\ 3y \ ��- , 1 1 ', tQl no of pro ed Covenants, Rec. No.123147 ``\ jC 233. 1 ; I ( Activlty,Fnvelope (typical)7750 700 `< Found No. 5 Rebar ::::::::. ` ` \ \ r --��\ \ ` ♦ \ \ \ \ t '. I F ..tet..,.:.. ` `\ _ � \ \\ `I OF 7760 7q : ::.... C...... . \` Proposed26'k,3lY ' - - _ 93.59' I `\ 1`♦ ` \ \ \\ \\ \\ `\1.. `\\ `\ 2 r Gare e\ , ' 31.... ♦\ \ , i, TO N TO •tip :C:: ♦ \ \ ••- v .Y:,:::::: �.�..sy::::�:: 4::.:::;:::::: \ \ 1 \ 1 \ 7770P •••`,'. •: \`\ ,`rya 1 .:.....t:.:....,.... \ , \ \ \ I \ 1 I I `y� < P ..........:. .S... \ I ` ` 1 \ 1 11 t 1 1 1 � f R-35SEWE I `� `�"�:•;}:::::d , \�+ \ \ 1 +I +1 1 It It `\` :::•\••.•. •� •,. �.:: \ \` \\ THIO LESIWEEP. ' "E '. ` D `•::;; � \\ . ; \\i 1 It\ `\ Ol1Y IN 2% ,` ♦`,,, t .. /�/`` 2' DIA SCH3l0 T I(I • ` '1 c:::. , \ I 1 ,� 1 1 `•.: ✓...1.-•� ` I \t�T STI 5:::�•II:•• \ \ 1 1 1 1 LINEAFTER \` �`� 21 '. :::j i i 111 [ B 1 < li , TTRFA ENIt��. ::� I � 1 \ AX20R .{... 1.... , \ 1 \ \ \ l \ I 1 1A6V MO �ai::•: •i? \ \ \ UNIT WITH •'.! I ;,;:;:�,II\\ 11 } 46105W ys. .. :li 13 I3 :...::::� \\ �`� �� ORENCO.'PF 05:;::t..;j::::1 \ I, c �C4ESS A'i •'.::::::; t'::.• ...:7 \ \ \ \ L.:::t:::.0 ... (' N ` 1 I I 1 1 \ 1 ..1..:fcii: ` \ \ \ - PUMP' J r.::::Y;::: •• \ 11 + '. RAbE s152SIi A SCF)•40 PUMP ` 1250 -GA L6N. / i-;;;+: 1 I 1 t "E:�ADV WITH AIR TWO -CO F1tRT161EF1 '.s I �`\ .$ 11 IK 1 1 , �FV1kLVEA\THIGH \ `.\ CONCRE $zp-11U,i1ANKi f�� .C. ra'.♦ , I 1 1 V P III I \ 1 ' 5 1 i 1 1 ` ::3•. :.1 \ 1 ♦ .'{a1 v ` \ G , I I 1 I c 1 1 < k :::�•'•' ::1. \1 \` O � _ �� `� `, \ pp3y, 11 � I I ; 11 � I 1 1 II 1`, B \`v 1 :::1:. \ 1 O` I♦ ` `\ • W, A :: �. 125" A ``\ ... ..: ..: ::i:t:ii:: PV Sts pipe ` i I ( ; I 1 v SGIM-0 PIP TO `\ :::?i :::t:::. , (Ex,sm� `\. f\6 D-BRX S Y:::::. 1 ` ` 1 °L 1 I i i i v C ...I •• . 't71 ♦`\ 1°iw. ♦`\`::::::((I \` `\\\ .. ;<1 1 1 1� 1 tl / / 11 i 1 1i , C ��\ \ •' :.,•• )i:::: :.. IST::::: X1 ``, �1 <' ;. 1 r (gr,�eled) / / I 11 i ; , \,( \ •.::: i::::.'t'.:::. •::;:.1:::::.1 \ d i L 1 i I I � / I I 1 I 7 LaCa110n of on-site wastewater \ \ \ ..:. •, �!•,: 1C:::::3:::::. :::::1:::: :;; +I , , I 1 1 /v < ♦ ..... ...: 5:::::....., 5::::::C::::::::::?:::' I A. J I I 1 1 1 1 O 2 treatments system (OWTS) \ \ ♦ \ �':::::';;;;,1:::::�::::;. \ •J ::•a 1 r 1 1 1 ` ♦ .. H la Famay Residence �L I I + , esdesigned byAll Service Septic, \ ( \ \ •••••• 'P.I."SR13:35 s (• ':)• ` (•:::::...,..... .. wood Fvne c°mwca°n t I I I \ I 1 + 8 Project No. C1110 \ \ \ (....... .. ;.1. •::. 1 I I , 1 1 1 •�< \ \ (:::::.':::::..J22950pper Rend) Reed , \ \ .. yy ,�}••;u;:;Y':::. .. Y• Aspen,C0. 81611 •::�. \ \ 1 1 \ •I.. Benc�tm8rk:1'PPNatI 1 1 \ \ BCE �..... _ S ,rS11V �:::. 9 • ..j.... ayF \\ \ Elpv 7�d9.50 ` ♦. .::[:::::.p{�v.E� MN2%31 (;'.• ---- -- �::::: '3 ; 1 YlfaterM�ter .59STEM WITFt ..... t z Odlllneofp !� t• �:::::: •::::��=_=- `\ a::::: .A 103.8 \ ♦ ( , \ c...,' ...I...hq: :..::: S P O IDE '%` \ \ \ Q 3 \ :: N:: 1 v•••• ,\ Storage •\•. Pmposellseloca igivewry \\ I \\ \\ \\ �..: ... .......�:1L • •<�::.��:::.5 �� f/ I ,�� 5: ♦ `. 1`E :i. 6 `N \ `,:::y:.: r::::: �i,::... :::i::::::s•:::::. :.l \ \� 1 1 S ` \ \ I \ + 1 T • , ...v::::... + 1 '. I , L.• •. o w �`�:::::::.:::: `s�::...... ,...... ..... .•:!,��,� \`\ \`-��� , + \ � ' \ potline fpro ed \ \ \ I Activity IF�vall \ ♦ ..... :::::: 5:::[).. )... \....... ..1::::::3:::::.1:, :. \ \ 1 \ \ \ \ °� \ \\ I I 1 I \ \ .t 1 1 ' ' ..... ... .. .. .fi..�::.:: �)IJ(line\Ofproposed � �• ,' Se o. Re , ty�nveb ..g: a.raP,P>f <+<<< Al No. S \ .. I....... 3 \ \ ` 1.......'::::..)'":::::C:::::I:.::.. \..... ..d YI�]'t ....7:::::::1:::::: 5::::: ..... 1 \ ••• 1 `S \ \ .....1......y...... ................ 1 r� le t yi \ ...1.::::1::.... ::1.....1.:.... .. < / ::::•:....., iYd IFxm f \ ...4J::. . 5, ec { \ \ ..�•:::::. " abet IPlas. .. � Fbund R ::::v::: N 7198 \ ,:....I . 0 29030 .�..... PLSN . < ...... ..................>-:....... �.....-,..... .... .. ...:. ..t.::/,: .. I Cep,, . Q / ............... ........ .........�........> ........,......... ............. ..... �....:.�::::.,,..�.......1.`....S.t......�: Else. Trens.,Phon4aRc( ...Y ..l . 7730 d UGI. Pold'- •::'�::::::::. " TV Risers an I 1. :.t l: ........ .... "::::::::a�:>s., ;::......., v':.::::^::::::...�:::::::..• i ..;.... 7741 15'Non usiveDi ay and .. <"'::::::.:.. :.K1:.•: . ... _ ,.........x. ............................t`:::::::'.ti�:.:::::`.::: ...... ...... .... ...... Access easem Bk. 352,Pgs.972-97 " 7750 - /+ GRAPHIC SCALE .y.\... \ 7760 20 0 10 20 40 00 �'` `�%� � � tea, Dy,,.,•. .: ti�:i::. .-v^..��'i:'....,....�,.:::::. 1 Y::?.....:,:::. \♦\ \ 11 17770 780 +;1�eterMeters::•`�,� "�� r. ..w:`:.4::: -E \ I ( IN I?= ) --"-.{ ':�:.'�^•„� ��' `�'' �`\\ i 1 1 Inch >• 20 & o •�'�':"•'""�" \ ``♦`� '7780 All Linear Dimensions Shown Hereon Are In US Survey Feet is Wo � # don F\nce 1 `.• ``�` \` Contour Interval Is 2.0' Vertical Elee. ----- x ` 'Mate V 7790 x x \ Found No. 5 Rebar 7804 k NOTICE: (ACCORDING TO C.R.S.1380.105 Er. SEOJ ACCORDING TO COLORADO LAW YOU MIDST COMMENCE ANY LEGALACTION BASED UPON ANY DEFECT IN THIS SURVEY WTTIM THREE YEARS AFTERYOU DISCOVER SUCH DEFECT. IN NO EVENT, MAY ANY ACTION BASED UPON ANY DEFECT IN THIS IMPROVEMENT SURVEY BE Activity Envelope Plan Of Lot 4, Block 2 Brush Creek Village Filing No. 2 SITUATED IN SECTION 21, TOWNSHIP 9 SOUTH, RANGE 85 WEST OF THE 6TH P.M. COUNTY OF PITKIN, STATE OF COLORADO URVEYORS' CERI7FICAIION: OWNER'S ACKNOWLEDGMENT AND DISCIAAffiL' THE UNDERSIGNED, BEING A LICENSED PROFESSIONAL LAND SURVEYOR IN THE STATE APPLICANT ACKNOWLEDGES ALL HAZARD BEAST INFORMED FE PITKIN PROPERCOUNTY. THE IDGSIII4CH OF ENVIRONMENTAL trA�.ttn AREAS THAT MIGHT AFFECT THE PROPHRTY,ANY COLORADO DO HEREBY CERTIFY THAT THIS MONUME•NTED LAND, IMPROVEMENT AND IMPROVEMENT'S, AND THE USE AND OCCUPANCY THEREOF. THE PROVISIONS OF THE PITKIN pOGRAPHIC SURVEY WAS PREPARED FOR TAD. D. AND KATHRYN E. HUNDERTMARKBY COUNTY REGULATIONS DO NOT IN ANY WAY ASSURE OR IMPLY THAT AREAS OUTSIDE OF ME AND UNDER MY DIRECT SUPERVISION AND CHECKING AND THAT IT IS TRUE AND CORRECT' DESIGNATED HAZARD AREAS WILL BE FREE FROM HAZARDS, OR THAT APPROVED MITIGATION THE BEST OF MY KNOWLEDGE AND BELIEF. MEASURES WILL GUARANTEE THE SAFELY OF ANY PROPERTY. FURTHER CERTIFY THAT THE IMPROVEMENTS ON THE PARCEL INDICATED ON THIS DATE, JULY 28, 2014, EXCEPT UTILITY CONNECTIONS, ARE ENTIRELY WITHIN THE BOUNDARIES OF THE PARCEL, EXCEPT AS SHOWN, THAT THERE ARE NO ENCROACHMENTS UPON THE DESCRIBED DATE REMISES BY IMPROVEMENTS ON ANY ADJOINING PREMISES, EXCEPT AS INDICATED, AND THAT OWNER THERE IS NO APPARENT EVIDENCE OR SIGN OF ANY FASEMENT CROSSING OR BURDENING ANY PA OF SAW PARCEL, EXCEPT AS NOTED. ALL INFORMATION PERTAINING To OWNERSHIP AND OTHER EASEMENTS OR ENCUMBRANCES COMMUNITY DBV6LOP 4ENr DIRECTOR: RECORD HAS BEEN TAKEN FROM A TITLE INSURANCE COMMITMENT PREPARED BY STEWART 1. ACTMTY ENVELOPE HAS BEEN REVINWED AND APPROVED BY THE PITKIN COUNTY ME, INC, TITLE INSURANCE COMMITMENT ORDER NO. 0 133043835, EFFECTIVE DATE COMMUNITY DEVELOPMENT DIRECTOR TIES _DAY OF .204 SUBJECT LY 01, 2014 AT 8A0 AM TO ADMINISTRATIVE DECISION NO. RECORDED AS RECEPTION NO. Y: SAMUEL D. PHELPS OL.ORADO LICENSED PROFESSIONAL Preliminary for review LAND SURVEYORNO. 27613 r COMM[JNIIY DEVELOPMENT DI2ECI.OR GRAND ON BEHALF OF SURVOO, INC. and comment COLORADO CORPPORATION ATE OF CERTIFICATION: 28/JULY/2014 CLERK & RECORDER ACCEPTANCE: ROPERTY DESCRIPTION: THIS ACTIVITY ENVELOPE HAS BEEN ACCEPTED FOR FILING IN THE OFFICE OF THE CLERK AND LOT 4, BLOCK 2 RECORDER OF PITKIN COUNTY, COLORADO, ON THIS DAY OF . 20 RUSH CREEK VIIAGE FILING NO.2 CCORDING TO THE SUBDIVISION PIAT THEREOF IN PLAT BOOK_ AT PAGE . AS RECEPTION NO. AS FI.RD FORRECORD IN PLAT BOOK3 AT PAGE 96 OUNTY OF PITKIN TATE OF COLORADO ONTAINS 2.054 ACRES AS DESCRIBED. DAM, PITKIN COUNTY CLERK AND RECORDER TRI ADDRESS: 95 UPPER RANCH ROAD ASPEN, Co. 1611 (NOT WITHIN MUNICIPAL LmIITS) BY: DEP VLY URVEYORS NOTES: HEARINGS AS SHOWN HEREON ARE BASED UPON A RECORD BEARING OF N.79°0124"E FOR THE NORTH LINE OF THE SUBJECT PROPERTY. MONUMBNTATION BEING FOUND IN THE FIELD AS INDICATED HEREON- ) THIS SURVEY IS BASED UPON MONUMENTATION BEING FOUND IN THE FIELD AS INDICATED H RRON AND THE RECORD PLAT OF THE SUBJECT PROPERTY. ALL LINEAR DIMENSIONS SHOWN HEREON ARE IN US SURVEY FEEL'. DATE OF FIE[O SURVEY: JULY 18, 2014. THIS PROPERTY IS/MAY BE SUBJECT TO US PATENT RIGHTS, MINERAL. RESERVATIONS AND PROTECTIVE COVENANTS OF RECORD. ELEVATIONS AS SHOWN HEREON ARE DERIVED BY GPS gIERW METHODS AND ARE A CLOSE APPROXIMATION OF NAVD a8 ELEVATIONS. THIS PROPERTY IS ZONED AFRIO BY PITKIN COUNTY AND IS SUBJECT TO -ACTIVITY ENVELOPS" DETERMINATION BY THE COMMUNITY DEVELOPMENT DEPARTMENT. THIS PROPERTY MAY BE SUBJECT TO AN INGRESSMORFSS EASEMENT AS RESERVED IN DOCUMENTS RECORDED IN BOOK 227 AT PAGE 403 AND BOOK 232 AT PAGE 541 IN WHICH 1T{8 SPECIFIC LOCATION OF THE EASEMENT IS NOT DEFINED. 106954'00" W Iuolt,6 UU vv W$VJOY lVV oG w C 4' j':1 �' ♦ F � 1 _ y 1 21 -- a2' t _ .Sli 1 >- n a y I •' j / t , �' �; 0 i T 1 m F' rl G \ i 4, Y )G ( 106°54'00" W 106°53'00" W WGS84106052'00" W TN JrMN ° 1000 VITIRS Y ID, f�ao6 TIEf 0 600 Pr ntedBom TOP01®2000 WAIllomr Plodoetions (w\ w to!M wnl) Vicinity Map SurvCo, Inc. Slope Analysis within deslgnated"ActivltyEnvelope" RTK GPS and Conventional Land Surveying Services No shading Slopes 0%to 29.99% 826-1/2 Grand Avenue Post Office Box 2782 1 Slopes 30% to 44.99% Glenwood Springs, CO. 81602-2782 Slopes 45%+ Phone: (970) 945-5945 Fax: (970) 945-5946 Email: survco C<9gmatl.com L Date: 28/July/2014 Sheet Client: Tad and Kathryn Hundertmark dwg file: 14.026.001 1 Of 1 Job No.: 14.026 Drown By. S. Phelps N0. BY DATE REVISION DESCRIPTION URVEYORS NOTES: HEARINGS AS SHOWN HEREON ARE BASED UPON A RECORD BEARING OF N.79°0124"E FOR THE NORTH LINE OF THE SUBJECT PROPERTY. MONUMBNTATION BEING FOUND IN THE FIELD AS INDICATED HEREON- ) THIS SURVEY IS BASED UPON MONUMENTATION BEING FOUND IN THE FIELD AS INDICATED H RRON AND THE RECORD PLAT OF THE SUBJECT PROPERTY. ALL LINEAR DIMENSIONS SHOWN HEREON ARE IN US SURVEY FEEL'. DATE OF FIE[O SURVEY: JULY 18, 2014. THIS PROPERTY IS/MAY BE SUBJECT TO US PATENT RIGHTS, MINERAL. RESERVATIONS AND PROTECTIVE COVENANTS OF RECORD. ELEVATIONS AS SHOWN HEREON ARE DERIVED BY GPS gIERW METHODS AND ARE A CLOSE APPROXIMATION OF NAVD a8 ELEVATIONS. THIS PROPERTY IS ZONED AFRIO BY PITKIN COUNTY AND IS SUBJECT TO -ACTIVITY ENVELOPS" DETERMINATION BY THE COMMUNITY DEVELOPMENT DEPARTMENT. THIS PROPERTY MAY BE SUBJECT TO AN INGRESSMORFSS EASEMENT AS RESERVED IN DOCUMENTS RECORDED IN BOOK 227 AT PAGE 403 AND BOOK 232 AT PAGE 541 IN WHICH 1T{8 SPECIFIC LOCATION OF THE EASEMENT IS NOT DEFINED. 106954'00" W Iuolt,6 UU vv W$VJOY lVV oG w C 4' j':1 �' ♦ F � 1 _ y 1 21 -- a2' t _ .Sli 1 >- n a y I •' j / t , �' �; 0 i T 1 m F' rl G \ i 4, Y )G ( 106°54'00" W 106°53'00" W WGS84106052'00" W TN JrMN ° 1000 VITIRS Y ID, f�ao6 TIEf 0 600 Pr ntedBom TOP01®2000 WAIllomr Plodoetions (w\ w to!M wnl) Vicinity Map SurvCo, Inc. Slope Analysis within deslgnated"ActivltyEnvelope" RTK GPS and Conventional Land Surveying Services No shading Slopes 0%to 29.99% 826-1/2 Grand Avenue Post Office Box 2782 1 Slopes 30% to 44.99% Glenwood Springs, CO. 81602-2782 Slopes 45%+ Phone: (970) 945-5945 Fax: (970) 945-5946 Email: survco C<9gmatl.com L Date: 28/July/2014 Sheet Client: Tad and Kathryn Hundertmark dwg file: 14.026.001 1 Of 1 Job No.: 14.026 Drown By. S. Phelps N0. BY DATE REVISION DESCRIPTION TN JrMN ° 1000 VITIRS Y ID, f�ao6 TIEf 0 600 Pr ntedBom TOP01®2000 WAIllomr Plodoetions (w\ w to!M wnl) Vicinity Map SurvCo, Inc. Slope Analysis within deslgnated"ActivltyEnvelope" RTK GPS and Conventional Land Surveying Services No shading Slopes 0%to 29.99% 826-1/2 Grand Avenue Post Office Box 2782 1 Slopes 30% to 44.99% Glenwood Springs, CO. 81602-2782 Slopes 45%+ Phone: (970) 945-5945 Fax: (970) 945-5946 Email: survco C<9gmatl.com L Date: 28/July/2014 Sheet Client: Tad and Kathryn Hundertmark dwg file: 14.026.001 1 Of 1 Job No.: 14.026 Drown By. S. Phelps N0. BY DATE REVISION DESCRIPTION