Pitkin County Environmental Health Department
Onsite Wastewater Treatment System (OWTS) USE PERMIT
Permit for Continued Use of an Existing OWTS
76 Service Center Road, Aspen, CO 81611
+' Phone: 970-920-5070 Fax: 970-920-5077
www.aspenpitkin.com/EHNR
Parcel la #: 2467-201-02-016
OWTS Use Permit#: 10017.2017.POWU
Date Issued: 3/13/2017
Issued By: Bryan Daugherty
Expiration Date: 3/13/18
Owner(s): I Pam Mulleavey
Property Address:
34 Eddie Lane
Legal Description:
Absorption Area
Licensed Inspector:
Carla Ostberg
Inspection Date(s):
1/31/17
SYSTEM INFORMATION
Components
Type
Capacity/Size
Primary Treatment Unit
Concrete 2 -compartment tank
1500 Gallons
Secondary Treatment Unit
Absorption Area
Pipe and gravel trenches
1815 ftZ
Other System Components
®In use at the time of the inspection. ❑Not in use at the time of the inspection.*
*lf the OWTS was not in use at the time of the inspection, it is recommended that the system be re-evaluated when it is in use for a more accurate
evaluation of the system.
System Records:
Permit #: 89002 Date of Issuance: 3/6/89 Date of Final Approval: 9/15/89
# of Bedrooms or fixtures served by OWTS: System is shared between several units, this unit is 2 bedrooms.
Operational Status: According to the inspectors observations at the time of inspection the system was functioning as
designed. The tank had been pumped recently and had tees and baffles in place. The field area did not show any signs
of failure such as surfacing effluent.
Inspector Recommendations: Inspector recommends adding an effluent filter to the outlet of the tank to prevent solids
from reaching the field area. Install an outlet tee on 1St tank in series serving this residence. Maintenance provider
should determine which units are served by which systems.
Department Recommendations: N/A
issuance of this OWTS Use Permit is based solely on the conditions observed and reported by the Inspector to the Department on the date of the Inspection(s) and
on Department records at the time of permitting. The issuance of this permit does not constitute a guarantee, warranty, or representation by the Department
that the system will operate properly or will not fail or that the system will not be subject to future enforcement action to correct non-compliant conditions.
Estimated capacity of the system has been listed on the permit and we recommend that you monitor and/or meter water use to prevent overuse andpossible
failure.
Pitkin County Environmental Health Department
} Onsite Wastewater Treatment System (OWTS)
' r USE PERMIT APPLICATION
76 Service Center Rd
Aspen, CO 81611
Website: www.aspenpilkin.com/ehnr/
Aonlication for Continued Use of an Existina OWTS
Parcel ID# (available from the Pitkin County Assessor's Office
Ccmpany,
970-920-5160 or at www.i)itkinassessor.org►:
C ty, State, Zip.
Coli Phone.
Purpcse of Use Permit.
PROPERTY 1 RANSACT[ON
[REMODELIADDiFIO(~J
Property Address
3 q Edd" k4
!_j i35 Mail
Lot Block.
Filing
Subdivisbn
Resdences:
Other
V of Bedrooms ^
fi:xlures uses:
Prerty Owner(s)' Finail Address
Q
0,ti-,er's 1vlailing Address -Iy_ State, Zip.
Hcme Phone BuseTa
on
i�3 �•/i6w Ca r�Fnr�P t �'o gld
Contact inforrnahon must he provided for the owner s,gninq 117is application
Primary Contact Person Applicant (if not o. Teri
Ccmpany,
Conlac::Apphcant Maiiirg Address.
C ty, State, Zip.
Coli Phone.
Business Phone:
Fa'; Number.
Email Address:
Ind :ate Preferred Method of Pern,:l Receipt
Email ❑ Fax
!_j i35 Mail
Lic used 5stems pec or. Pone Number, Email Address: Fax Number,
V� 97 3 5, S71 vs- r ' •nowt
Mailing Address, City. State, Zip
3 3 W r v•Ott E bnVAA0 Lf
PLEASE READ B-Fr')RE- SIGNING:
I certify that the above information is complete and accurate and that I have provided complete and accurate information in all of the documents
included in my application package_ I acknowledge that this department may revoke any permit I am issued if my application is found to contain any
inaccurate, false, or misleading information
O".ner jigs a (Req Ve ! Date
!1 11/iu&— r
App::canl Signat - Date I
Please allow 3-5 business days for processing of Use Permits.
IFOR OFFICE USE ONLY
Received by EH Staff Fee & Recelp! f� Gate
Onsite Wastewater Treatment Systems (OWTS) Use
F Permit Inspection Form
Pitkin County Environmental Health Department
76 Service Center Rd, Aspen, CO 81611
Phone:970-920-5070 Fax: 970-920-5374
Website'."t:p,'IpAincouniycoml246V,as:ea,aler-lrealmenI
Inspection form for continued use of an existing OWTS
Owner's Name:
Address:
Parcel Number:
Inspection Date:
Inspector's Name:
Business Name:
Phone Number
Email:
Pam J. Muileave
34 Eddie Lane
Basalt. CO
2467 201 02 016
January 31, 2017
Carla Ostber
CBO Inc.
970 309-5259
carla.ostberg@gmail.com
Pitkin County Systems Inspector License Number: 1017
A copV of this ins echon re art will be remitted to Pitkin Coupty Environmental Health Department b
the Licensed Systems Inspector within 60 days of the inspection regardless of whether the s stern
passes or fails.
QUESTIONS FOR PROPERTY OWNER PRIOR TO INSPECTION:
Is the home currently occupied? 7 -YES ❑N
If NO, how long has the home been vacant?
How many bedrooms are in the home? 12
If secondary treatment is used, who is the
maintenance provider? I nla
RECORDS:
Were system records available from Pitkin County? ❑YES Q N 0
If YES: Permit number:
Date of Final Approval:
# of bedrooms permitted.0
Was an as -built drawing available? ❑ YES F_-] NO
Is the as -built drawing accurate? ❑YES ❑NO
If NO: Complete a drawing of the system on last page of this form as accurately as
possible.
Any question marked FAIL will require correction before an OWTS Use permit is issued.
SITE CONDITIONS:
Proper grading, no evidence of erosion? ❑PASS El FAIL
Improper vegetative cover? : NO ❑ YES
Evidence of compaction such as heavy machinery or livestock? NO YES
Improper discharges such as straight pipes? F_ -]PASS ❑FAIL
Evidence of high ground water? ❑ NO ❑ YES
Snow cover present? ❑ NO F7- YES
Page 1 Effective Date 111212017
TANK:
tanks are between 1000 �
and 1500 gallons - confil
with pumping records
Tank 1 Tank 2
Tank 3
Tank capacity
gallons
gallons
gallons
Tank material
concrete
concrete
# of compartments
Date of last pumping
Summer 2016
Summer 2016
Lids/risers in good condition
Pass
Pass
Select One
Risers to grade
Yes
Yes
Select One
Riser height
3'
3'
Riser condition/watertightness
OK
OK
Inlet sanitary T/baffle
Pass
Pass
Select One
Outlet sanitary T/baffle
Fail
Pass
Select One
Effluent filter (if part of design)
N/A
N/A Iselect
One
Condition of tank material
Pass
Pass
Select One
Tank was pumped for inspection
No
Select One
Select One
If YES, list the pumping company
If NO, when was the last pumping
Summer 2016
Summer 2016
Scum level (1st compartment)
inches
inches
inches
Sludge level (1st compartment)
inches
inches
inches
Scum level (2nd compartment)
inches
inches
inches
Sludge level (2nd compartment)
inches
inches
inches
Backflow (if pumped)
Select One
Select One
Select One
Midtank baffle
Select One ISelect
One
Select One
Watertightness
Pass
Pass
Select One
PUMPS/DOSING SIPHONS:
Is a pump or dosing siphon present?® YES NFAIL NO
mIf YES, is the pup/dosing siphon functienrng properly? PASS
Does the pump/wiring/dosing siphon appear to be in good condition? ❑PASS ❑FAIL
Is the high water alarm working, both visible and audible? ❑PASS ❑FAIL
SECONDARY TREATMENT:
Is a secondary treatment unit present? ❑YES 0 NO ❑UNKNOWN
If YES, does the unit appear to be in good working condition? HYES
❑YEs ❑ NODoes the owner have a current maintenance contract for the unit? NO UNKNOWN
Maintenance Provider: n+a I Phone
If there is no maintenance contract, a contract must be in place prior to occupancy of the home. A
copy of the contract must be submitted to Pitkin County Environmental Health Department
ABSORBTION AREA:
Effluent surfacing?
Evidence of past surfacing?
Surface dampness?
Excessive odors?
Field location verified by observation ports or probing:
Liquid in observation port?
If YES, record depth:
Distribution Box or ADV part of original design?
If YES, is it accessible from grade?
Is it level and in good condition?
F]PASS
'❑
"❑
■
HFAIL
NO YES
NO ❑ YES
NO ❑ YES
Ports Probing
NO"
NO YES
YES NO
YES NO
PASS FAIL
UNKNOWN
Page 2 Effective Date 1/1212017
6
-,lease ns{ any rerammencrauons Tor the continuea use or [ne system:
• Work with whoever is managing andlor pumping the OWTSs to assure there is good
documentation regarding which residences are served by each OWTS in the subdivision.
• Install an outlet tee on the pipe existing the first septic tank serving 34 Eddie Lane.
• Install effluent f0ters on all outlet tees. If installed, these filters must be cleaned annually, or as in
Were any repairs done as a result of this inspection? D DYES
if YES please describe the repairs.
To the best of my knowledge and training, the information collected in this inspection is accurate as of
February 320 17 .
Licensed Systems Inspector Signature: =erg
Additional Notes
Clearty label any pictures and attach them to this form.
Save Form Ctear Form
Print Form
Page 3 Effective Date 111212017
February 3, 2017
Pam Mulleavey
pumlleaveyC,,iL gmai i.com
CBO Inc.
33 Four Wheel Drive Roar!
Carbondale. CO 81623
cell) 970-309-5259 office) 970-704-0484
carla.ostberqC@,qrnaiI.com
Onsite Wastewater Treatment System (OWTS) Use Permit Inspection
34 Eddie Lane
Pitkin County. Colorado
Pam,
As requested, CBO Inc. performed an Onsite Wastewater Treatment System (OWTS) Use Permit
inspection at 34 Eddie Lane, Basalt, Colorado on January 31. 2017. The legal description of the property
is Lot 7, Unit 1, Hoaglund Ranch Historic Subdivision.
Pitkin County Environmental Health Department has a variety of permits and drawings for Hoaglund
Ranch-, however. those that we reviewed appeared to be inconsistent with what we found on the property
(Parcel ID #2467-201-02-016). Hoaglund Ranch Homeowner's Association (HOA) manages the OWTSs
serving residences within Hoaglund Ranch. Without drawings or past pumping invoices, we are not
certain of the sizes of the septic tanks. but the subject OWTS consists of two concrete septic tanks and a
soil treatment area (STA) of unknown size and configuration. The system serves multiple residences.'
The septic tanks are located to the west of the subject residence and south of what appears to be an
uninhabited historic barn. Four manhole lids are accessible from grade with 3 -feet of risers. We turned
the water on from a sink in 34 Eddie Lane and let it run through the course of the inspection. We
observed water coming into the first septic tank through a 6 -inch diameter tee. There was also a 4 -inch
diameter tee entering the side of the septic tank. There was no tee on the pipe existing the first septic
tank. We are not sure if these two tanks are connected in series. but are in close proximity to one
another. The second septic tank has 4 -inch tees entering both the end and side of the tank. A 4 -inch
outlet tee exits the end of the second septic tank.
The Hoaglund Ranch HOA manages pumping operations and reported the last pumping of these septic
tanks occurred in the Summer of 2016 by Kelly Gessle. Levels in both septic tanks were normal at the
time of our inspection.
There was snow cover at the time of our inspection. We observed an inspection port in the yard area to
the southwest of the septic tanks. The inspection port was dry. We walked the approximate STA and
found no evidence of surface saturation or failure at the time of our inspection. This evaluation is not a
guarantee of future system performance. This inspection is good for one year.
Recommendations (HOA):
• Work with whoever is managing and/or pumping the OWTSs to assure there is good
documentation regarding which residences are served by each OWTS in the subdivision.
• Install an outlet tee on the pipe existing the first septic tank serving 34 Eddie Lane.
• Install effluent filters on all outlet tees. If installed. these filters must be cleaned annually. or as
needed.
Lot 1 is served by a separate OWTS Lots 3, 4, 5 and Lot 11 are served by separate OWTSs.
This report and a completed OWTS Use Permit Application must be submitted to the Pitkin County
Environmental Health Department. Applications may be submitted to Pitkin County Environmental Health
Department electronically. The following are links to the required OWTS Use Permit Application and
Checklist.
Application: http://www.pitkincounty.com/DocumentCenter/HomeNiew/621
Application Checklist: http://www.pitkincounty.com/DocumentCenter/HomeNiew/620
All questions regarding permit submission can be directed to Pitkin County Environmental Health
Department, 970-920-5070.
Disclaimer: This inspection is intended only as an evaluation of the present condition of the OWTS
based upon what was observed and the Licensed Inspector's expertise in onsite wastewater technology.
The Inspector has not been retained to warrant or guarantee the proper functioning of the system for any
period of time in the future. Because of numerous factors which may affect the operation of an OWTS,
as well as the inability of the Inspector to supervise or monitor the use or maintenance of this OWTS, this
report shall not be construed as a warranty by the Inspector that the system will function properly for any
particular prospective buyer, and the Inspector disclaims any warranty, either expressed or implied,
arising from the inspection of the OWTS or this report. The evaluation does not ascertain the impact the
system is having on groundwater.
Please call with questions.
Sincerely,
(yt,q Com.. o.� &A
s
Carla Ostberg, MPH, REHS
NAWT Certified Inspector
Certification # 11 0441T Exp. April 2018
View of septic tank lids (first tank)
(second tank near trees)
7
r
Inlet tees (6" through end and 4" side) Outlet pipe (no tee)
Second tank (two inlets)
Outlet tee second tank
View of tank lids looking toward 34 Eddie Lane View of tanks looking toward historic barn
Approximate STA and inspection port
approx. location of STA
(size and configuration
unknown)
If no as -built drawings exist for this system or the as -built was inaccurate, please diagram the system as
accurately as possible. Be sure to document all system components and the location of any well on the
property. Using markers such as corners of the house, exact measurements can be used to triangulate
the location of the system components for future reference.