HomeMy WebLinkAboutpitkin.eh.246720102016 (2017)COUNT Pitkin County Environmental Health Department Onsite Wastewater Treatment System (OWTS) USE PERMIT Permit for Continued Use of an Existing OWTS 76 Service Center Road, Aspen, CO 81611 +' Phone: 970-920-5070 Fax: 970-920-5077 www.aspenpitkin.com/EHNR Parcel la #: 2467-201-02-016 OWTS Use Permit#: 10017.2017.POWU Date Issued: 3/13/2017 Issued By: Bryan Daugherty Expiration Date: 3/13/18 Owner(s): I Pam Mulleavey Property Address: 34 Eddie Lane Legal Description: Absorption Area Licensed Inspector: Carla Ostberg Inspection Date(s): 1/31/17 SYSTEM INFORMATION Components Type Capacity/Size Primary Treatment Unit Concrete 2 -compartment tank 1500 Gallons Secondary Treatment Unit Absorption Area Pipe and gravel trenches 1815 ftZ Other System Components ®In use at the time of the inspection. ❑Not in use at the time of the inspection.* *lf the OWTS was not in use at the time of the inspection, it is recommended that the system be re-evaluated when it is in use for a more accurate evaluation of the system. System Records: Permit #: 89002 Date of Issuance: 3/6/89 Date of Final Approval: 9/15/89 # of Bedrooms or fixtures served by OWTS: System is shared between several units, this unit is 2 bedrooms. Operational Status: According to the inspectors observations at the time of inspection the system was functioning as designed. The tank had been pumped recently and had tees and baffles in place. The field area did not show any signs of failure such as surfacing effluent. Inspector Recommendations: Inspector recommends adding an effluent filter to the outlet of the tank to prevent solids from reaching the field area. Install an outlet tee on 1St tank in series serving this residence. Maintenance provider should determine which units are served by which systems. Department Recommendations: N/A issuance of this OWTS Use Permit is based solely on the conditions observed and reported by the Inspector to the Department on the date of the Inspection(s) and on Department records at the time of permitting. The issuance of this permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail or that the system will not be subject to future enforcement action to correct non-compliant conditions. Estimated capacity of the system has been listed on the permit and we recommend that you monitor and/or meter water use to prevent overuse andpossible failure. Pitkin County Environmental Health Department } Onsite Wastewater Treatment System (OWTS) ' r USE PERMIT APPLICATION 76 Service Center Rd Aspen, CO 81611 Website: www.aspenpilkin.com/ehnr/ Aonlication for Continued Use of an Existina OWTS Parcel ID# (available from the Pitkin County Assessor's Office Ccmpany, 970-920-5160 or at www.i)itkinassessor.org►: C ty, State, Zip. Coli Phone. Purpcse of Use Permit. PROPERTY 1 RANSACT[ON [REMODELIADDiFIO(~J Property Address 3 q Edd" k4 !_j i35 Mail Lot Block. Filing Subdivisbn Resdences: Other V of Bedrooms ^ fi:xlures uses: Prerty Owner(s)' Finail Address Q 0,ti-,er's 1vlailing Address -Iy_ State, Zip. Hcme Phone BuseTa on i�3 �•/i6w Ca r�Fnr�P t �'o gld Contact inforrnahon must he provided for the owner s,gninq 117is application Primary Contact Person Applicant (if not o. Teri Ccmpany, Conlac::Apphcant Maiiirg Address. C ty, State, Zip. Coli Phone. Business Phone: Fa'; Number. Email Address: Ind :ate Preferred Method of Pern,:l Receipt Email ❑ Fax !_j i35 Mail Lic used 5stems pec or. Pone Number, Email Address: Fax Number, V� 97 3 5, S71 vs- r ' •nowt Mailing Address, City. State, Zip 3 3 W r v•Ott E bnVAA0 Lf PLEASE READ B-Fr')RE- SIGNING: I certify that the above information is complete and accurate and that I have provided complete and accurate information in all of the documents included in my application package_ I acknowledge that this department may revoke any permit I am issued if my application is found to contain any inaccurate, false, or misleading information O".ner jigs a (Req Ve ! Date !1 11/iu&— r App::canl Signat - Date I Please allow 3-5 business days for processing of Use Permits. IFOR OFFICE USE ONLY Received by EH Staff Fee & Recelp! f� Gate Onsite Wastewater Treatment Systems (OWTS) Use F Permit Inspection Form Pitkin County Environmental Health Department 76 Service Center Rd, Aspen, CO 81611 Phone:970-920-5070 Fax: 970-920-5374 Website'."t:p,'IpAincouniycoml246V,as:ea,aler-lrealmenI Inspection form for continued use of an existing OWTS Owner's Name: Address: Parcel Number: Inspection Date: Inspector's Name: Business Name: Phone Number Email: Pam J. Muileave 34 Eddie Lane Basalt. CO 2467 201 02 016 January 31, 2017 Carla Ostber CBO Inc. 970 309-5259 carla.ostberg@gmail.com Pitkin County Systems Inspector License Number: 1017 A copV of this ins echon re art will be remitted to Pitkin Coupty Environmental Health Department b the Licensed Systems Inspector within 60 days of the inspection regardless of whether the s stern passes or fails. QUESTIONS FOR PROPERTY OWNER PRIOR TO INSPECTION: Is the home currently occupied? 7 -YES ❑N If NO, how long has the home been vacant? How many bedrooms are in the home? 12 If secondary treatment is used, who is the maintenance provider? I nla RECORDS: Were system records available from Pitkin County? ❑YES Q N 0 If YES: Permit number: Date of Final Approval: # of bedrooms permitted.0 Was an as -built drawing available? ❑ YES F_-] NO Is the as -built drawing accurate? ❑YES ❑NO If NO: Complete a drawing of the system on last page of this form as accurately as possible. Any question marked FAIL will require correction before an OWTS Use permit is issued. SITE CONDITIONS: Proper grading, no evidence of erosion? ❑PASS El FAIL Improper vegetative cover? : NO ❑ YES Evidence of compaction such as heavy machinery or livestock? NO YES Improper discharges such as straight pipes? F_ -]PASS ❑FAIL Evidence of high ground water? ❑ NO ❑ YES Snow cover present? ❑ NO F7- YES Page 1 Effective Date 111212017 TANK: tanks are between 1000 � and 1500 gallons - confil with pumping records Tank 1 Tank 2 Tank 3 Tank capacity gallons gallons gallons Tank material concrete concrete # of compartments Date of last pumping Summer 2016 Summer 2016 Lids/risers in good condition Pass Pass Select One Risers to grade Yes Yes Select One Riser height 3' 3' Riser condition/watertightness OK OK Inlet sanitary T/baffle Pass Pass Select One Outlet sanitary T/baffle Fail Pass Select One Effluent filter (if part of design) N/A N/A Iselect One Condition of tank material Pass Pass Select One Tank was pumped for inspection No Select One Select One If YES, list the pumping company If NO, when was the last pumping Summer 2016 Summer 2016 Scum level (1st compartment) inches inches inches Sludge level (1st compartment) inches inches inches Scum level (2nd compartment) inches inches inches Sludge level (2nd compartment) inches inches inches Backflow (if pumped) Select One Select One Select One Midtank baffle Select One ISelect One Select One Watertightness Pass Pass Select One PUMPS/DOSING SIPHONS: Is a pump or dosing siphon present?® YES NFAIL NO mIf YES, is the pup/dosing siphon functienrng properly? PASS Does the pump/wiring/dosing siphon appear to be in good condition? ❑PASS ❑FAIL Is the high water alarm working, both visible and audible? ❑PASS ❑FAIL SECONDARY TREATMENT: Is a secondary treatment unit present? ❑YES 0 NO ❑UNKNOWN If YES, does the unit appear to be in good working condition? HYES ❑YEs ❑ NODoes the owner have a current maintenance contract for the unit? NO UNKNOWN Maintenance Provider: n+a I Phone If there is no maintenance contract, a contract must be in place prior to occupancy of the home. A copy of the contract must be submitted to Pitkin County Environmental Health Department ABSORBTION AREA: Effluent surfacing? Evidence of past surfacing? Surface dampness? Excessive odors? Field location verified by observation ports or probing: Liquid in observation port? If YES, record depth: Distribution Box or ADV part of original design? If YES, is it accessible from grade? Is it level and in good condition? F]PASS '❑ "❑ ■ HFAIL NO YES NO ❑ YES NO ❑ YES Ports Probing NO" NO YES YES NO YES NO PASS FAIL UNKNOWN Page 2 Effective Date 1/1212017 6 -,lease ns{ any rerammencrauons Tor the continuea use or [ne system: • Work with whoever is managing andlor pumping the OWTSs to assure there is good documentation regarding which residences are served by each OWTS in the subdivision. • Install an outlet tee on the pipe existing the first septic tank serving 34 Eddie Lane. • Install effluent f0ters on all outlet tees. If installed, these filters must be cleaned annually, or as in Were any repairs done as a result of this inspection? D DYES if YES please describe the repairs. To the best of my knowledge and training, the information collected in this inspection is accurate as of February 320 17 . Licensed Systems Inspector Signature: =erg Additional Notes Clearty label any pictures and attach them to this form. Save Form Ctear Form Print Form Page 3 Effective Date 111212017 February 3, 2017 Pam Mulleavey pumlleaveyC,,iL gmai i.com CBO Inc. 33 Four Wheel Drive Roar! Carbondale. CO 81623 cell) 970-309-5259 office) 970-704-0484 carla.ostberqC@,qrnaiI.com Onsite Wastewater Treatment System (OWTS) Use Permit Inspection 34 Eddie Lane Pitkin County. Colorado Pam, As requested, CBO Inc. performed an Onsite Wastewater Treatment System (OWTS) Use Permit inspection at 34 Eddie Lane, Basalt, Colorado on January 31. 2017. The legal description of the property is Lot 7, Unit 1, Hoaglund Ranch Historic Subdivision. Pitkin County Environmental Health Department has a variety of permits and drawings for Hoaglund Ranch-, however. those that we reviewed appeared to be inconsistent with what we found on the property (Parcel ID #2467-201-02-016). Hoaglund Ranch Homeowner's Association (HOA) manages the OWTSs serving residences within Hoaglund Ranch. Without drawings or past pumping invoices, we are not certain of the sizes of the septic tanks. but the subject OWTS consists of two concrete septic tanks and a soil treatment area (STA) of unknown size and configuration. The system serves multiple residences.' The septic tanks are located to the west of the subject residence and south of what appears to be an uninhabited historic barn. Four manhole lids are accessible from grade with 3 -feet of risers. We turned the water on from a sink in 34 Eddie Lane and let it run through the course of the inspection. We observed water coming into the first septic tank through a 6 -inch diameter tee. There was also a 4 -inch diameter tee entering the side of the septic tank. There was no tee on the pipe existing the first septic tank. We are not sure if these two tanks are connected in series. but are in close proximity to one another. The second septic tank has 4 -inch tees entering both the end and side of the tank. A 4 -inch outlet tee exits the end of the second septic tank. The Hoaglund Ranch HOA manages pumping operations and reported the last pumping of these septic tanks occurred in the Summer of 2016 by Kelly Gessle. Levels in both septic tanks were normal at the time of our inspection. There was snow cover at the time of our inspection. We observed an inspection port in the yard area to the southwest of the septic tanks. The inspection port was dry. We walked the approximate STA and found no evidence of surface saturation or failure at the time of our inspection. This evaluation is not a guarantee of future system performance. This inspection is good for one year. Recommendations (HOA): • Work with whoever is managing and/or pumping the OWTSs to assure there is good documentation regarding which residences are served by each OWTS in the subdivision. • Install an outlet tee on the pipe existing the first septic tank serving 34 Eddie Lane. • Install effluent filters on all outlet tees. If installed. these filters must be cleaned annually. or as needed. Lot 1 is served by a separate OWTS Lots 3, 4, 5 and Lot 11 are served by separate OWTSs. This report and a completed OWTS Use Permit Application must be submitted to the Pitkin County Environmental Health Department. Applications may be submitted to Pitkin County Environmental Health Department electronically. The following are links to the required OWTS Use Permit Application and Checklist. Application: http://www.pitkincounty.com/DocumentCenter/HomeNiew/621 Application Checklist: http://www.pitkincounty.com/DocumentCenter/HomeNiew/620 All questions regarding permit submission can be directed to Pitkin County Environmental Health Department, 970-920-5070. Disclaimer: This inspection is intended only as an evaluation of the present condition of the OWTS based upon what was observed and the Licensed Inspector's expertise in onsite wastewater technology. The Inspector has not been retained to warrant or guarantee the proper functioning of the system for any period of time in the future. Because of numerous factors which may affect the operation of an OWTS, as well as the inability of the Inspector to supervise or monitor the use or maintenance of this OWTS, this report shall not be construed as a warranty by the Inspector that the system will function properly for any particular prospective buyer, and the Inspector disclaims any warranty, either expressed or implied, arising from the inspection of the OWTS or this report. The evaluation does not ascertain the impact the system is having on groundwater. Please call with questions. Sincerely, (yt,q Com.. o.� &A s Carla Ostberg, MPH, REHS NAWT Certified Inspector Certification # 11 0441T Exp. April 2018 View of septic tank lids (first tank) (second tank near trees) 7 r Inlet tees (6" through end and 4" side) Outlet pipe (no tee) Second tank (two inlets) Outlet tee second tank View of tank lids looking toward 34 Eddie Lane View of tanks looking toward historic barn Approximate STA and inspection port approx. location of STA (size and configuration unknown) If no as -built drawings exist for this system or the as -built was inaccurate, please diagram the system as accurately as possible. Be sure to document all system components and the location of any well on the property. Using markers such as corners of the house, exact measurements can be used to triangulate the location of the system components for future reference. i - - _T. - .' t + i _f j _`--•t r --� (-- . i t / Page 4 1 f j h t F i I ; -.:.Cw;-t- / Page 4 1