Onsite Wastewater Treatment System (OWTS) USE PERMI
Permitfor Continued Use of on Existing OWTS I
76 Service Center Road, Aspen, CO 81611
Phone: 970-920-5070 Fax: 970-920-5077
www.aspenpitkin.com/EHNR
Parcel ID #: 2467-174-01-014
OWTS Use Permit #: I 0066.2016.POWU
Date Issued: 11/21/2016
Issued By: Bryan Daugherty
Expiration Date: 11/21/2017
Owner(s): I Peter and Brigitte Abplanalp
Property Address:
142 Holland Hills Rd
Legal Description:
Lot 18, Holland Hills
Licensed Inspector: Carla Ostberg
Inspection Date(s): 11/8/16
Components
Type
Capacity/Size
Primary Treatment Unit
2 compartment concrete tank
2 compartment concrete tank
1000 gallons
1000 gallons
Secondary Treatment Unit
Absorption Area
Pipe and gravel bed
"infiltrator" trenches
1300 ftz
1100 ft2
Other System Components
®In use at the time of the inspection. ❑Not in use at the time of the inspection.*
*If the OWTS was not in use at the time of the inspection, it is recommended that the system be re-evaluated when it is in use for a more accurate
evaluation of the system.
System Records:
Permit #: 77104 & 92043 Date of Issuance: 3/17/78 & 7/30/92 Date of Final Approval: 3/31/78 & 4/13/93
# of Bedrooms or fixtures served by OWTS: This system is designed to serve 6 bedrooms
Operational Status: According to the inspectors observations the system was functioning as designed. Both tanks were in good,
water -tight condition with inlet and outlet tees in place. The tanks gravity flowed to a distribution box that was not accessible from
grade that split flows between the 1977 bed and 1992 addition of trenches. There were no observation ports to check for standing
effluent, there was no evidence of failure
Inspector Recommendations: Continued maintenance.
Department Recommendations: N/A
Issuance of this OWTS Use Permit is based solely on the conditions observed and reported by the inspector to the Department on the date of the inspection(s) and
on Department records at the time of permitting. The issuance of this permit does not constitute a guarantee, warranty, or representation by the Department
that the system will operate properly or will not fail or that the system will not be subject to future enforcement action to correct non-compliant conditions.
Estimated capacity of the system has been listed on the permit and we recommend that you monitor and/or meter water use to prevent overuse and possible
failure.
t k W W
Parcel ID# (available from the Pitkin County Assessor's Office
Company:
970-920-5160 or at www.pitkinassessor.org):
-s
Purpose of Use Permit:
I� ,�/ PROPERTY TRANSACTION
❑ REMODEL/ADDITION
Property Address:
Indicate Preferred Method of Permit Receipt:
Email ❑ Fax
❑ US Mail
Lot: Block:
/
Filing:
Subdivision:
Residences:
Other
# of Bedrooms:
fixtures/uses:
Property Owner(s)*: Email Address:
Owner's Mailing Address: City, State, Zip:
Home Phone: Business Phone:
97® - g27 4,/q- 941 q-1® - -Z7 7
*Contact information must be provided for the owner signing this application.
Primary Contact Person/Applicant (if not owner):
Company:
Contact/Applicant Mailing Address:
City, State, Zip:
Cell Phone:
Business Phone:
Fax Number:
Email Address:
Indicate Preferred Method of Permit Receipt:
Email ❑ Fax
❑ US Mail
Licensed Systems Inspector r Phone Number Email Address: Fax Number:
,.�
hf
Mailing Address: City, State, Zip:
u
2
P_
PLEASE READ BEFORE SIGNING:
I certify that the above information is complete and accurate and that I have provided complete and accurate information in all of the documents
included in my application package. I acknowledge that this department may revoke any permit I am issued if my application is found to contain any
inaccurate, false, or misleading information.
Owner Signature(Required): Date:
Applicant at Date:
Please allow 3-5 business days for processing of Use Permits.
Received by EH Staff: Fee & Receipt #: Date:
�G
On66e2C�fG.i�o�JU
November 12, 2016
Peter Abplanalp
pompoms bplanalps.net
Onsite Wastewater Treatment System (OWTS) Use Permit Inspection
124 Holland Hills Road
Pitkin County, Colorado
Peter,
As requested, CBO Inc. performed an Onsite Wastewater Treatment System (OWTS) Use Permit
inspection at 124 Holland Hills Road, Basalt, Colorado on November 8, 2016. The legal description of
the 2.1 -acre property is Lot 18, Holland Hills at Basalt.
The permits and record drawings were provided by Pitkin County Environmental Health Department
(Parcel ID #2467-174-01-014). The subject OWTS consists of two 1000 -gallon, two-compartment
concrete `VCP' septic tanks. Effluent gravity flows to a distribution box, and distributes effluent between
the original (1977) 13'x 100' pipe and gravel soil treatment area (STA) and two chamber trenches
(1993), each with 17 `Standard' Infiltrator® chambers. The original OWTS is documented by Pitkin
County Health Department Permit Number 77104, which was given final approval on March 31, 1978.
Additional STA was added under Individual Sewage Disposal System Permit 92043. The system was
sized to accommodate 6 bedrooms. The permit received final approval on April 13, 1993.
The septic tanks are located to the southwest of the residence. These septic tanks have access two
access points to the inlet side of the septic tank and one access point to the outlet side of the septic tank.
Only the inlet sides were accessible initially; however, the outlet access was dug up and brought to grade
with a sprinkler box. Inlet and outlet baffles have a PVC tee cast into the concrete. The concrete outlet
baffle on both septic tanks are showing signs of significant deterioration, but are still intact.
The first septic tank in the series was pumped by B&R Septic at the time of our inspection. The second
septic tank in the series did not have enough solids accumulated to warrant pumping.
The distribution box was not accessible and therefore, we were not able to inspect this component. We
recommend locating the distribution box and making it accessible from grade for future monitoring and
inspection. We walked the approximate STA and found greener grass over one of the trenches. No
inspection ports were visible in the STA. There were no signs of surface saturation or evidence of failure
at the time of our inspection.
This evaluation is not a guarantee of future system performance. This inspection is good for one year.
Recommendations:
® Locate distribution box and bring it to grade.
This report and a completed application packet must be submitted to the Pitkin County Environmental
Health Department. The following links are the required application and application checklist.
CBO Inc.
33 Four Wheel Drive Road
Carbondale, CO 81623
cell) 970-309-5259 office) 970-704-0484
carla.ostberg&gmail.com
November 12, 2016
Peter Abplanalp
pompoms bplanalps.net
Onsite Wastewater Treatment System (OWTS) Use Permit Inspection
124 Holland Hills Road
Pitkin County, Colorado
Peter,
As requested, CBO Inc. performed an Onsite Wastewater Treatment System (OWTS) Use Permit
inspection at 124 Holland Hills Road, Basalt, Colorado on November 8, 2016. The legal description of
the 2.1 -acre property is Lot 18, Holland Hills at Basalt.
The permits and record drawings were provided by Pitkin County Environmental Health Department
(Parcel ID #2467-174-01-014). The subject OWTS consists of two 1000 -gallon, two-compartment
concrete `VCP' septic tanks. Effluent gravity flows to a distribution box, and distributes effluent between
the original (1977) 13'x 100' pipe and gravel soil treatment area (STA) and two chamber trenches
(1993), each with 17 `Standard' Infiltrator® chambers. The original OWTS is documented by Pitkin
County Health Department Permit Number 77104, which was given final approval on March 31, 1978.
Additional STA was added under Individual Sewage Disposal System Permit 92043. The system was
sized to accommodate 6 bedrooms. The permit received final approval on April 13, 1993.
The septic tanks are located to the southwest of the residence. These septic tanks have access two
access points to the inlet side of the septic tank and one access point to the outlet side of the septic tank.
Only the inlet sides were accessible initially; however, the outlet access was dug up and brought to grade
with a sprinkler box. Inlet and outlet baffles have a PVC tee cast into the concrete. The concrete outlet
baffle on both septic tanks are showing signs of significant deterioration, but are still intact.
The first septic tank in the series was pumped by B&R Septic at the time of our inspection. The second
septic tank in the series did not have enough solids accumulated to warrant pumping.
The distribution box was not accessible and therefore, we were not able to inspect this component. We
recommend locating the distribution box and making it accessible from grade for future monitoring and
inspection. We walked the approximate STA and found greener grass over one of the trenches. No
inspection ports were visible in the STA. There were no signs of surface saturation or evidence of failure
at the time of our inspection.
This evaluation is not a guarantee of future system performance. This inspection is good for one year.
Recommendations:
® Locate distribution box and bring it to grade.
This report and a completed application packet must be submitted to the Pitkin County Environmental
Health Department. The following links are the required application and application checklist.
Application:
httD://www.Ditkincountv.com/DocumentCenter/HomeNiew/621
Application Checklist:
http://www.pitkincounty.com/DocumentCenter/HomeNiew/620
t
Disclaimer: This inspection is intended only as an evaluation of the present condition of the OWTS
based upon what was observed and the Licensed Inspector's expertise in onsite wastewater technology.
The Inspector has not been retained to warrant or guarantee the proper functioning of the system for any
period of time in the future. Because of numerous factors which may affect the operation of an OWTS,
as well as the inability of the Inspector to supervise or monitor the use or maintenance of this OWTS, this
report shall not be construed as a warranty by the Inspector that the system will function properly for any
particular prospective buyer, and the Inspector disclaims any warranty, either expressed or implied,
arising from the inspection of the OWTS or this report. The evaluation does not ascertain the impact the
system is having on groundwater.
Please call with questions.
Sincerely,
a �' ('a"-
Carla
Ostberg, MPH, REHS
NAWT Certified Inspector
Certification # 110441TC Exp. April 2018
Access to inlet side of tank
Access to middle (inlet side) of tank
View of access to septic tanks
Location of septic tank (looking northwest)
View looking southeast
View of STA (note greener grass over trench)
Outlet sides of septic tank (note deteriorating concrete)
Accesses to outlet side of septic tank made accessible from grade
Map of tank access
Onsite Wastewater Treatment Systems (OWTS) Use
Permit Inspection Form
Pitkin County Environmental Health Department
76 Service Center Rd, Aspen, CO 81611
Phone: 970-920-5070 Fax: 970-920-5374
Website: www.aspenpitkin,comLehnr
inspection form for continued use of an existing OWTS
_
owner's Name: U
Address: ,,A"
J_
Parcel Number:
L
a 'PAA12
Inspection Date:
Inspector's Name:
Business Name:
Phone Number
Email: L) I � � —r-fj In
7
Pitkin County Systems Inspector License Num1ben—,
.... ...... .
A co o this ins ection re port Dvill be remitted to Pitkin Qwnty Environmental Health Departrrientby,_
Me- Licensed SIV.Stems h :1,;'pector within 60 da s ox the in,:,oction re f whether t
passes or &I is.
QUESTIONS FOR PROPERTY OWNER PRIOR TO INSPECTION:
r
Is the home currently occupied? YES NO
If NO, how long has the home been vacant?
How many bedrooms are in the home?
If secondary treatment is used, who is the
maintenance provider?
RECORDS:
Were system records available from Pitkin County? YES NO
3
If YES; Permit number. 2-0
Date of Final Approval:
# of bedrooms permitted:
Was an as -built drawing available? NO
Is the as -built drawing accurate? NO
If NO: Complete a drawing of the system on lost page of this form as accurately as
possible.
Any question marked FAIL will require correction before an OWTS Use permit is Issued.
SITE CONDITIONS: P "_)C4
Proper grading, no evidence of erosion? PAS FAIL t
YES
improper vegetative cover?
Evidence of compaction such as heavy machinery or livestock?
YES
improper discharges such as straight pipes? PASS FAIL
Evidence of high ground water?YES
Snow cover present? C—N-00 YES
Page 1
TANK:
Tank I
N/A
Tank 2
FAIL /A
Tank 3
Watertightness FAIL
Tank capacity
L? 0
gallons
jt zs
gallons
gallons
Tank material
f
of compartments
is a pump or dosing siphon present?
Date of last pumping
C—_NO_-
If YES, is the pump/dosing siphon functioning properly?
PASS
FAIL
Lids/risers in good condition
Does the pump/wiring/dosing siphon appear to be in good condition?
FAIL
FAIL
PASS
FAIL
Risers to grade
PASS
_YE
NO
YES
NO
Riser height
Is a secondary treatment unit present?
YES
LNO':>
UNKNOWN
Riser con diti on/watertightness
If YES, does the unit appear to be in good working condition?
YES
NO
Does the owner have a current maintenance contract for the unit?
Inlet sanitary T/.�:=af
ONASS'
FAIL
4 S---,
—P -se:-,
FAIL
PASS
FAIL
Outlet sanitary/ §aff_----->
I e
_pASV
FAIL -
If there is no maintenance contract., a contract must be in place prior to o,-cupancy
FAIL
PASS
FAIL
Effluent filter (if part of design)
PASS FAIL
PASS FAILC��A
PASS FAIL
N/A
Condition of tank material
�p
FAIL
FAIL
PASS
FAIL
Tank was pumped for inspection
YE
NO
YES NO)
YES
NO
If YES, list the pumping company
4f�'
If NO, when was the last pumping
Scum level (1st compartment)
inches
inches
inches
Sludge level (1st compartment)
inches
inches
inches
Scum level (2nd compartment)
inches
inches
inches
Sludge leve .. 1 .1 2nd compartment)
inches
inches
inches
Backflow (if pumped)
FAIL
S'�
FAIL
PASS
FAIL
FAIL
�1,-
FAIL N/AE_ FAIL
Midtank baffle S
N/A
PASS
FAIL /A
"P
Watertightness FAIL
FAIL
PASS
U
�pl P IVIPS/DOSING SIPHONS:
is a pump or dosing siphon present?
YES
C—_NO_-
If YES, is the pump/dosing siphon functioning properly?
PASS
FAIL
Does the pump/wiring/dosing siphon appear to be in good condition?
PASS
FAIL
is the high water alarm working, both visible and audible?
PASS
FAIL
SECONDARY TREATMENT:
Is a secondary treatment unit present?
YES
LNO':>
UNKNOWN
If YES, does the unit appear to be in good working condition?
YES
NO
Does the owner have a current maintenance contract for the unit?
YES
NO
UNKNOWN
Maintenance Provider: -Phone:
If there is no maintenance contract., a contract must be in place prior to o,-cupancy
pf the
home, A
copy of the contract must be submitted to Pitkin County Environmental Health Departmen't.
ABSORBTION AREA:
Effluent surfacing?
Evidence of past surfacing?
Surface dampness?
Excessive odors?
Field location verified by observation ports or probing
Liquid in observation port?
If YES, record depth:
Distribution Bo x or ADV part of original design?
If YES, is it accessible from grade?
Is it level and in good condition?
CfPnA
�Si SS
,0,
`-N
N
Ports
NO
FAIL
YES
YES
YES
Probing
YES
inches
NO
ES �� NO.�
PASS FAIL
Page 2
UNKNOWN
Any problems with the system that were not addressed in the inspection checklist?
Please listny recommendations for the
k
use
Were any repairs done as a result of this inspection?
If YES, please describe the repairs.
the system:
M
To th best of my knowledge and training, the information collected in this inspection is accurate as of
20
Licensed Systems inspector Signature:
�y
Additional motes:
Cleariv label any Octures and attach them to this form,
Page 3
. - ���
�� ��r
d
f�.�
F �<
e
�C
a , e' I
�{�
� ;��,
�'. ,
;�
i
i
\!
I
�
f
I
��
,�; ��
�, .
� ��
� �
�_
����
�,3
r�
� d
�
��.
F �<
e
�C
a , e' I
�{�
� ;��,
�'. ,
;�
i
i
\!
I
�
it
� ���'}��
�
�
!
t{
,� �
� �� �
���
'
Al