HomeMy WebLinkAboutpitkin.eh.273503100001 (2004)Pitk ;ounty Environmental Health Departi it
Permit for an Individual Sewage Disposal System
0405 Castle Creek Road, Suite 10, Aspen, Colorado 81611
Phone 970-920-5070 / FAX 970-920-5077
Permit # 04092 Parcel ID # 9735-031-00-80-5-- '�- 3r5—bbL_0o—co I
Type of permit New(X) Repair( ) Addition/Remodel to House( )
Name of Owner Buttermilk Basin, LLC
Street Address 501 West Buttermilk Road
Property legal description
Size of lot 37 acres Total square footage of the house -7000
Water source Private well - will be Community Water (W. Buttermilk Metro District)
# of bedrooms in house 3 # of offices, lofts & similar sized rooms in house
Caretaker unit Attached Total square footage of the caretaker unit 1404
# of bedrooms in caretaker unit 2 # of offices, lofts & similar sized rooms in caretaker unit
Designed for what # rooms (list) 5 bedrooms
Permit information
Designed by Church and Associates
Mailing Address 4501 Wadsworth Boulevard Wheat Ridge CO 80033
Perc rate 48 mpi Profile hole depth 8 ft Depth to groundwater or bedrock Greater than 8 ft
Minimum Septic tank capacity 2844 gallons Minimum Absorption area 1576 w/ 50% reduction
Comments
Septic permit approved per compliance with the engineer design and specifications dated October 18, 2004. Any
changes must be approved by this department and the design engineer prior to them being made.
Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin
County ISDS regulations. There must be a minimum 202 foot setback to the well from the field.
This system will consist of one 2000 gallon single compartment tank followed by one 1000 gallon two compartment
tank with an effluent filter on the outlet. The effluent will be distributed via distribution box to 8 trenches. There
must be at least 6 feet of undisturbed soil between each trench. There should be 20 Quick 4 chambers in each
row, for a total of 160 chambers.
This department does not endorse any brand of products. This permit must be kept on-site during installation.
The engineer must do a final inspection of the installation and submit an as -built letter to this department. This
department must also be called for an inspection with a minimum of 48 hours advanced notice.
*Revegetation over the area of the field is very important for the functioning of the system. Pitkin County has guidelines that must be
followed to assure the plants that are introduced are appropriate for the conditions of the area. The use of native plants is strongly
en
Permit approved by: �aLaJ�qDate: t 4 t t M
Plans and specifications of the proposed individual sewage disposal system have been reviewed and are considered
satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin
County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was
issued unless system construction has commenced or an extension has been approved in writing by the Department.
As -built drawings must be included with this permit before the final approval will be issued.
Installer: f a4,ka4- Z,6u- —'
Final approval: �yQC� �C' Date:
L�
PITKIN CULINTY ENVIRONMENTAL HEALTH DEPARTMENT
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM
0405 Castle Creek Road, Suite 10, Aspen Colorado 81611
Phone (970) 920-5070 Fax (970) 920-5077
Name of OWNER�-�-
Owner's Mailing Address k. WACj1 jp1 y�
City, State, Zip Z t Business Phone: � o. `-z-7, 4&C
Home Phone: E-mail Address:
Primary
Contact Person (all communication regarding this permit will go through this person)
Name
,4
CompanyG
�/' ?�
Contact Mailing Address , U;
�W uSZ
City, State, Zip
3
Business Phone: Z'7-7 "--7
Cell Phone:
Fax : z v, 17-Z7 rc s
E-mail Address: dg c�o
Parcel ID # (available from assessor's offic
at 920-5160 or at www.pitkinassessor.org )
Building Permit # (if available)
Street address of property
Legal Description: Lot Block
Size of lot: !ti 1 7 acres.
,Filing
Type of proposed structure:
,Subdivision
Total square feet of house -7oW # of bedrooms (potential) in house
Caretaker Unit: Attachedp< ) Detached ( )
Total areas . ft. of caretaker unit 4` # of bedrooms(potential) in caretaker unit
Permit is for: New Home ) Repair due to failure ( ) Remodel/Addition ( ) Emergency use ( )
Water: Private well ( ) Spring ( ) Stream ( ) Community/Public Water System
If community system: Name of system'¢� J =V� u<— Mari-r.� i�,p <--t^
The fee for a ISDS application is $600 for a permit that takes 6 hours or less for the department to approve. If approval takes
longer than 6 hours, a rate of $100 per hour will be charged. The maximum fee is $1000. The basic fee of $600 is due at the
time of application. The remainder, if any, will be due in two stages: first, at the time of issuance of the ISDS permit; second,
before final approval of the ISDS permit.
Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information is true and
accurate and that I have provided true and accurate information on locations of all existing and proposed wells, contour
intervals, buildings, property lines, ditches, slopes, waterlines, springs, suction or irrigation lines, drinking water cisterns, drain
tiles, irrigation ditches, lakes, water courses, streams, floodplains, dry gulches, and existing septic systems. I hereby certify that
any such features not shown on attached site map are not present. Issuance of the permit does not imply the approval of any
other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all approvals
and permits have been obtained.
The Pitkin County Environmental Health Department, Pitkin County and employees of these agencies will be held harmless
should the individual sewage disposal system fail or malfunction. The permit to construct is issued on information submitted by
the applicant or his/her representatives. The owner assumes full re"nsibi ' ingse of failure of the system.
Signature of applicant
Received by
G:\isds\isds applic\isdsapp rev072904.doc
0
Date
Receipt # a�� Date
PRO - 1:
TABLE 1 - PERCOLATION TEST RESULTS
Burlingame Ranch
Pitkin County, Colorado
DATE OF TEST: 11/05102
acv% a —. IB 1,
0 - 1 Topsoil, root zone
1 -8 Sand, clayey, angular and rounded boulders and gravel, dense,
moist, red/brown
NO GROUNDWATER WAS ENCOUNTERED WITHIN EXCAVATION
JOB NO. 15364W
AVG.
INTERVAL
DEPTH TIME DEPTH DEPTH CHANGE, PERC.
HOLE
HOLE
OF HOLE, INTERVAL, START, END, (INCHES) RATE
PERC.
NUMBER
(INCHES) (MINUTES) (INCHES) (INCHES) (MPI)
RATE,
(MPII
JOB NO. 15364W
PRO -1:
TABLE 1 (CONT) - PERCOLATION TEST RESULTS
Burlingame Ranch
Pitkin County, Colorado
DATE OF TESTA 1/05/02
MUL UWO%,l IIJLKW.S
o-1 Topsoil, root zone
1 -8 ISand, clayey, an ular and rounded boulders and gravel, dense,
moist, red/brown
NO GROUNDWATER WAS ENCOUNTERED WITHIN EXCAVATION
NUMBER OF HOLES: 4
AVG PERCOLATION RATE (MPI): 48
JOB NO. 15364W
AVG.
INTERVAL
DEPTH TIME DEPTH DEPTH CHANGE, PERC.
HOLE
HOLE OF HOLE, INTERVAL, START, END,
(INCHES) RATE
PERC.
NUMBER (INCHES) (MINUTES) (INCHES) (INCHES)
(MPI)
RATE,
(MPII
NUMBER OF HOLES: 4
AVG PERCOLATION RATE (MPI): 48
JOB NO. 15364W
SECTION VIEW
SIDE VIEW
INFILTRATOR(R) QUICK4(TM) CUT SHEET
n
u
CHURCH & Associates, Inc.
ENGINEERS & GEOLOGISTS
December 22, 2004
Peak Construction Management, Inc.
Attn: Tim Bottger
P.O. Box 2052
Carbondale, Colorado 81623
Subject: Installation Observation, Proposed Residence 1 r
Tract 37, West Buttermilk, Burlirtffi�y�� R)
Pitkin County, Colorado, A V Lk
Job No. 15364W � V�' s -i 0 LL
J3� 35 -.0.21 - DU -905
Mr. Bottger,
As requested, we observed the installation of the onsite wastewater system for the subject site on
December 17, 2004. The system was designed under our Job No. 15364W, with a final revision date of
October 18, 2004.
The system includes the installation of a 2000 -gallon, single -compartment, concrete septic tank followed
by a 1000 -gallon, two-compartment, concrete septic tank with an effluent filter on the outlet, and eight
gravelless chamber -trenches. Each trench has one row of 13 chambers for a total of 104 chambers and
1612 ftz of infiltrative area. An as -built drawing is included as Figure 1.
The observed components of the OWS were installed in general conformance with our design. A licensed
electrician must make final electrical connections. Our installation observations do not imply a guarantee
or warranty of materials or workmanship.`•;.
Sincerely,
CHURCH & Associates, Inc.
Eric R. Burns
Field Technician
EOC/erb
3 copies sent
Copy to PCEHD, Attn: Nancy MacKenzie
DENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 80033
303.463.9317 Fax: 303.463.9321
• ..` L.J. pp••] v,^`''
�I 'S..q,i � •'cY dtl h�.v r.l..i
Reviewed by `�� ZZ-
E and O. Church, P.E.
www.geo-church.com
Toll Free -1.877.248.3123
House Size (sq. ft.) No= (75 gpd, 100 gpd, or 130 gpd)
Number of Bedrooms in Main House
Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House
Number of Bedrooms in Detached Caretaker unit
Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit
(If the caretaker unit is ATTACHED, treat as if part of main house.)
Average Daily Waste Flow 1300
State Review Required? no
Perc Rate I, !rI
Design Flow (Q) = # potential bedrooms X 2 people/bedroom X gpd X 1.75
Q= 2275
Absorptior Area (A= Q X SQRT T/5)
A = 3152 sq. ft. of absorption area required
203 infiltrator units without reduction
A maximum 50% reduction is allowed for use of deep gravel or gravelless chambered system,
only if the lot size and soil conditions are optimal.
If a reduction is being proposed, describe why lot size and soil conditions are optimal:
50% REDUTION TAKEN FOR GOOD PERCOLATION RATES AND USE OF GRAVELLESS CHAMBERS
A = 1576 sq.ft. with reduction
102 infiltrator units with reduction (159 min. Quick4 chambers)
Type of system: []Absorption trenches []Absorption bed [x] Gravelless chambers
[]Dry well []Seepage Pit []Other
Minimum tank capacity
SETBACK FROM WELL
# of feet = 202
SETBACK FROM POND, STREAM OR IRRIGATION DITCH
# of feet = 152
SETBACK FROM DRY GULCH
# of feet = 127
FINAL INSPECTION BY: DATE:
tri
Engineer's Submittal for Septic Permit in Pitkin County
Owner's Last Name: j /� / �S: Location: TRACT 37, WEST BUTTERMILK
Summary of information regarding new septic system:
Type of system being proposed: GRAVELLESS CHAMBER -TRENCHES
Other treatment processes being used: EFFLUENT FILTER
Does the system use any mechanical parts? (Prohibited unless there is no alternative) NO
If yes, explain why there are no alternatives
Does the system require any maintenance other than routine pumping? YES
If yes, who will do the maintenance? CLEAN FILTER WHEN SEPTIC TANK IS PUMPED
Are any reductions being proposed? YES
If yes, what makes the lot and soil conditions optimal?
GOOD PERCOLATION RATES AND PROPOSING TRENCHES
Which of the following are on the site or within setbacks?
Closest distance of septic system to each feature
[] 100 year floodplain
NA
[X] well(s)
>202 FEET
[] irrigation ditches
N/A
[] streams
[] ponds
N/A
[] other
N/A
What was the profile hole depth? 8 FEET
What is the depth to groundwater? N/A
What is the depth to bedrock?
What assumptions, if any, were made in system sizing and design? (Include any local, site-
specific data, such as months without snow cover, ratio of evaporation to absorption, etc. that are
relevant.)
If there are any variations from normal design, please explain how they can be demonstrated to
improve treatment and protect water quality. NONE
CHURCH & Associates, Inc.
ENGINEERS & GEOLOGISTS
October 18, 2004
Peak Construction Management, Inc., Attn: Tim Bottger
P.O. Box 2052
Carbondale, Colorado 81623
Subject: Revised OWS Design, Proposed Residence
Tract 37, West Buttermilk, Burlingame Ranch
Pitkin County, Colorado
Job No. 15364W
Mr. Bottger,
As requested, we have prepared a revised onsite wastewater system (OWS) for the proposed residence.
The revisions are based on changes to the residence from our latest revised design, dated December 30,
2002. All previous designs should be discarded to avoid confusion. The subsurface investigation was per-
formed on October 29, 2002.
SITE CONDITIONS
The property is in a residential area of Pitkin County, where OWS are required. The proposed drain field
area has an approximate 6 percent slope to the west and has a heavy cover of native grasses and sage.
Water is provided to the site by an onsite well located greater than 202 feet from the proposed drain field
area.
PROPOSED CONSTRUCTION
A three-bedroom residence with an attached two-bedroom caretaker unit is proposed at the location
indicated on Figure 1. Total living area for the structure is 7000 ft2. The revised OWS design is based on 5
bedrooms and an average daily loading of 1300 Gallons Per Day (GPD) using Pitkin County Environmental
Health Department (PCEHD) loading of 130 gallons per day per person. The sewage loading with a
peaking factor of 1.75 is 2275 GPD. This loading includes washing machines and garbage grinders.
If additional bedrooms in unfinished areas are possible, it is suggested that the OWS be constructed to
handle the additional loading. The installation of a properly engineered OWS to serve future build -out
can be cost effective.
SUBSURFACE CONDITIONS
The subsurface investigation was performed by digging four percolation holes, 28 to 39 inches deep, and
one profile hole at the locations indicated on Figure 1. Subsurface materials in the profile hole consisted of 1
foot of topsoil, underlain by clayey sand to the maximum depth explored of 8 feet. No ground water was
DENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 80033 www.geo-church.com
303.463.9317 Fax: 303.463.9321 Toll Free -1.877.248.3123
Revised OWS Design
Job No. 15364W, 10/18/04
Page 2
encountered. Percolation tests indicate percolation rates of 20 to 80 minutes per inch (MPI). The average
percolation rate is 48 MPI. Percolation data is presented in Table 1.
RECOMMENDATIONS
The installation must include two septic tanks, an effluent filter, and a gravelless chamber -trench drain
field at the locations presented on Figure 1. The OWS design is based on an average sewage load of
1300 GPD and a percolation rate of 48 MPI. The installation must include a 2000 -gallon, single -
compartment, concrete septic tank followed by a 1000 -gallon, two-compartment, concrete septic tank
with an effluent filter on the outlet and eight chamber -trenches. Each trench must have one row of 20
Infiltratorg Quick4TM chambers for a total of 160 chambers and 1587.2 ft2 of infiltrative area. The
trenches may be modified to conform to topography and to preserve as much vegetation as possible
using pivot points on the Quick4TM chambers. A concrete distribution box with a baffle,is required to
distribute effluent to the field.
Movement over the drain field trench during construction should be kept at a minimum to minimize
compaction of the receiving soils. The bottom of each trench must be scarified with a pick, shovel, or
backhoe bucket teeth prior to the addition of chambers.
The surface of the drain field should be seeded after installation of the system. A native seed mix from the
area available at seed stores should be used. These mixes do not require irrigation and develop a growth 10
to 15 inches high. No automatic sprinkler system should be installed over the field.
OPERATION AND MAINTENANCE
The owner must realize an OWS is different from public sewer service and must assume the responsibility
for maintenance of the OWS. The system is relatively maintenance free, but the owner must have the septic
tanks pumped. In the absence of a monitoring program, the septic tank should be pumped and the effluent
filter cleaned every two years. There are daily considerations, such as not putting plastic or other nonbiode-
gradable material into the OWS. Water use must be monitored so toilets are not allowed to run when seals
malfunction. To illustrate the point, a running toilet can consume in excess of 1000 GPD. A loading of 1000
GPD could flood and irreparably harm the OWS.
The loading from the backwash of a water softener may be harmful to the OWS. A separate drywell should
be constructed for the backwash waste, if a softener is installed. Chemically treated water from a swimming
pool or spas should not be introduced to the OWS.
LIlVITTATIONS
An OWS design requires installation by a licensed contractor. Our investigation, layout, design and recom-
mendations are based on data submitted. If conditions different from those described in this report are
encountered, we should be notified to evaluate the effect on the proposed OWS. If the health department
modifies this design, we should be contacted to evaluate the impact on the performance of the OWS.
All construction is to be in accordance with PCEHD ISDS regulations. Pipe type and size, burial
requirements, septic tank construction, and other specifications, which are not depicted in our report, are to
conform to the requirements of the ISDS regulations. The installer of the system is to have demonstrated
knowledge of the ISDS regulations and requirements.
If there are questions or if we can be of further service, please call.
Sincerely,
CHURCH & Associates Inc.
Reviewed by:
Eric R Burns Edward O. C:
Design Technician
EOC/erb
3 copies sent via FedEx to: Peak Construction Management, Inc.
Attn: Tim Bottger
204 Park Avenue, Suite #1D
Basalt, Colorado 81621
,,wo, Revised OWS Design
Job No. 15364W, 10/18/04
Page 3
2000 -Gallon, Single -Compartment, Concrete Septic Tank followed by one
1000 -Gallon, Two -Compartment, Precast Septic Tank with an Effluent Filter
SLOPE GROUND
AWAY FROM RISERS (TYP.)
INLET TEE
OR BAFFLE
CONDUIT T0—
ALARM PANEL
(OPTIONAL)
CONDUIT SEAL
LIQUID LEVEL
CLEAR ZONE OPENING IN
THE BAFFLE IS AN ACCEPTABLE
ALTERNATIVE TO PVC TEES
HIGH LEVEL
ALARM FLOA
PVC SPLICE BOX
W/CORD GRIPS
FIBERGLASS GASKETED
LID WITH STAINLESS
STEEL BOLTS AND
2" INSULATION
24" DIA. PVC RISER WITH
GROMMET(S) (BOND TO TANK
ADAPTER WITH RECOMMENDED
ADHESIVE)
FILTER CARTRIDGE HANDLE
(FIELD CUT TO DESIRED HEIGHT)
•
0n
Orenco Systems®
Incorporated
814 AIRWAY AVENUE
SUTHERLIN, OREGON
97479-9012
TELEPHONE:
(541) 459-4449
FACSIMILE:
(541) 459-2884
TANK ADAPTER (WATERTIGHT)
VENT ORIFICE
EFFLUENT DISCHARGE
MODULATING DISCHARGE ORIFICES
VAULT INLET PORTS
FILTER CARTRIDGE
BIOTUBE EFFLUENT FILTER
Patents # 4,439,323 do 5,492,635
OForeign Patents Pending
1997, Orenco Systems, Inc.
DISCLOSURE: THE PRESIDENT OF CHURCH a ASSOCIATES, INC. IS A NON -PARTICIPATING OWNER OF SCG ENTERPRISES, INC. WHICH IS A LOCAL DISTRIBUTOR
OF ORENCO SYSTEMS, INC. PRODUCTS. THIS DRAWING HAS BEEN MODIFIED BY CHURCH FOR THIS PROJECT.
*NOTE: OWNER MAY SELECT NOT TO INSTALL HIGH-WATER ALARM. HOWEVER, THE OWNER MUST ASSUME THE RISK OF POTENTIAL BACKUPS IF THE ALARM
IS NOT INSTALLED AND THE FILTER WAS TO BECOME CLOGGED.
CHURCH &Associates. Inc. JOB NO. 15364W
ENGINEERS &GEOLOGISTS TYPICAL TWO SEPTIC TANK WITH EFFLUENT FILTER
4501 Wadsworth Boulevard FIGURE 3
Wheat Ridge, Colorado
80033 Phone: (303) 463-9317
11-10-04 03:05PM FROM -DIVISION OF WATER RESOURCES 3038662223 T-844 P.02/03 F-681
_ F,LI, CONSTRUCTION AND TEST REPORT
FOR OFECEUSE. ONLY
STATE OF COLORADO, OFFICEOF THE STATE ENGINFER
cl S 6� ago
RECEIVED
WELL PERMIT NUM13ER -- 9 1—A
WELL
Na=(s): Aspen, City of Ann: Housing Office
JAN 2 12003
2-1
Mailing Address: 530 E. Main St. Lower Level
NATERRE SOURCES
City, State, Zip ; Aspen, Co. 81611
sr4n A
Phone # 970-920-5050
APPROVAL aGWS31-91-0]
_ NW IA SL 1/4 Sec: 3
3'
TWP: 10 S Range: 8886 W
DISTANCES FROM SEC. LINES
1740 ft. from South Sec- line and 2060 It. 6-orn East Sec. line OR
Northing: Fasting:
SUBDIVISION: LO'r: BLOCK:
FILING (UNIT):
STREET ADDRESS AT LOCATION
GROUND SURFACE ELEVATION ft. DRILLING METHOD Air Rotary
4.1
DATE COMPLETED: 11/4n_002 TOTAL DL -PTH; 495
DEPTH COMPLETION: 495
5.
GCOLOGIC LOQ
b- HOLE_ DiAM6TP_R (:n)
FROM (ft) TO (d)
Depth -fjpc of Material Size, Color, and a
9-0
0 100
000-075 Dirt, Rocky
6.5
]00 495
075-495 Mancos Shah
7. PI_ AIN CASING
OD (44)
Kind Wall Sia From (d) To (a)
7.0
Steel 0.240 -1
100
5.5
PVC 0.250 95
450
PERF. CASING : Screed Siet Size
!-
5-5PVC
r 0.250 450
495
!
11-10-04 03:05PM FROM -DIVISION OF WATER RESOURCES 3038662223 T-844 P.03/03 F-681
INSYI:"TION AN[! TW RWMRT
For Mae LA* o0y
_PLUP
I
STATE OF COLORAW, OFFICE OF TK SPATE ENCANEM
RECEIVED
DEC 16 2W2
W�7EafiF5Gi
1,
yyaL PM" NUMBER 220601 A
2IP110110
OWNERNAME(s) Jim Williams
���p� ^wJ.�,, y
MaWv Addra:ha 539 F N r4 � n s t=
S1eiE EW,,n..[,I
GG, G
C1ty, et zfp A�Pe CQ 81611
-0)
SG /.a1. -?Q
(97 920-5050
3
• NW 1/4_,SE 1/4,S6C. Twp_ 10S ,PIMQe55 W 6th
DWANCEB FROM BEC, WNES;
3 Z44- ,. h from �jMsec. Ime. am _2a8 n ft from F!ast Sok:. we,
SUBON&ON: FILNO(UNn)
STRI T ADM58 AT WELL LOCATION:
4.
PU pP DATA: Type Submersible tn&sgow CompNKW 1 1/ 19 / 0 2
" tNarhtlbcturer G o u d s Purrrp Modal No. 13 G S 3 0 412 L
Dwr UPM 33 at 3 5 n HP—h—, Votes 2 3 n Full Load An*v1 6 .6
Pump Me Dspth 490' Feat, DrtlplCokimrl Pipe Size " inches, Ki WUb 8Q PYc
A PUM6 GREM0 IM IQ 9M:
1WBfNE DRIVER TYPE: C30owic ❑ Eine MOM
DeOgn Howl teat. "bar of , stm t we Inch"
6.
Alr&w Ina Wled M Yas NA arfte Dep4h tt . Monter Tube trtetaNed ❑ Yea NO, Depth 11 -
flow Mater K*9.— — Mow Serial Na
Flow
Metes iisacbuk Q 4t ?a. 0 TttotteanQ GaRA(t6, 0 Aar feet, [] Ba it tirh� Ream -- -
❑ Check bolt N Tara data ss wrbro c/J r , 4upp1smental Form
1 C,
Date '11114102
TOO Wall Depth 498' Time 2 xu
611* Lawrl 1 3 2 ' Raie (GOO
Date Measured PuMpilp Lvl
7.
DJUNFEC7M: Type Chlorox _ ,&jM uod _ 2 Cups
&I
Water Quality wWyvW mrailWle. EIY= ❑ No
a
Remeft
Q I theins read ribs stwernenta mtme therein and know the COMM Owre01, and tthm they are true to my knOVAac7Ba
(Putwant to Section 24-4-104 (13)(4) QRS., the makft of tales stat mw= heraln constiwes per(ury in the swam
dogroe and IB puNsMWQ ars a CUM t fh%dwnvanor.]
CONTRACTOR _ J & M pump Co Phone (j7 01 9 4 5 -6159 Lit. Na 119 6.
McMnp Address 6 Co 117 Q1 601
Neme/rMe (Pteaae type or phtrip One
/�'
Richard A. Holub Oaner C9G %Z01 -n,
Permit # 03006
Pitkin County Environmental Health Department
Permit for an Individual Sewage Disposal System
0405 Castle Creek Road, Suite 10, Aspen, Colorado 81611
Phone 970-920-5070 / FAX 970-920-5077
Parcel ID # 2735-031-00-805
Type of permit New( X ) Repair( ) Addition/Remodel to House( )
Name of Owner Jim & Jill Williams
Street Address 0045 West Buttermilk Road Aspen, CO
Property legal description
Size of lot 37
Water source Private well
# of bedrooms in house 5
Caretaker unit Detached
# of bedrooms in caretaker unit
Designed for what # rooms (list)
Total square footage of the house 6392
# of offices, lofts & similar sized rooms in house
Total square footage of the caretaker unit
1189
2 # of offices, lofts & similar sized rooms in caretaker unit
5 bedrooms in the main house, 2 bedrooms in the caretaker unit
Permit information
Designed by Church & Associates
Mailing Address 4501 Wadsworth Boulevard, Wheat Ridge, CO A93
Perc rate 48 Profile hole depth 8 ft D to ground r or rock Greater than 8 ft
Minimum Septic tank capacity 3500 gallons mum Absor rea 1940 w/ 50% reduction
Commenl R` '11-
Septic permit approved per compliance wi a eng esign pecifications d ec er 30, 2002.
Any changes must be approved by this d ment and esign eergn made.
Minimum horizontal distances between nents of the tem and physical features all con rm t Pitkin
County ISDS regulations. The well must feet from th eld. Trenches must beat least 10 ei�o he
property line.
The system will consist of one 10 gallon tank rve the etaker it. The in h e one 2000
gallon single compartment tank foliived by a 10 Ion compartment tank. A flow lift asin or distribution
box will be used. There will be 10 trfVches, each mbers for a total of 130 a e There must be a
minimum 6 feet of separation betweeN each trench.
This department does norse any nd of products. This permit must be kept -site during installation.
The engineer must do a fin ection a installation and submit an as -built letter to this department. This
department must also be calle ins ion with a minimum of 48 hours advanced notice.
Permit approved by: ��l ��1� Date: —42KIZ -42 D
Plans and specifications of the proposed individual sewage disposal system have been reviewed and are considered
satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin
County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was
issued unless system construction has commenced or an extension has been approved in writing by the Department.
As -built drawings must be included with this permit before the final approval will be issued.
Installer:
Final approval: Date:
34'-0'
S' -v 5"e 5'-4" 5'4 81-10" 16'-4'
4'-0" 4' -0" -0" 5'-8" 3'-0' 3'-0" 4'-0" 4'-0" 4'-0"- 4'-0"
11.10.. 2'-4" '4'
II
II II II
Z5
----IF
--- - - --------
X
LUFLL (P
kX
xx
--4
4AN7W — — — — — — — —
um I a 11 IM
_j L
PjA� CEW4 —
7 F 5TUDY
ING 5�00M, F
L li I F _10-1 -1 0 MASAWAT
losII CAIWEPRAL CEIAG
— -------- —
"iWEDRAL CEI4W.
—I—
kx MASTER BEDROOM 0
(:Ixqx — - .9
_CATREDfZALCETLM-
DRE$SIWS
ry PAT
L J L
VESTIBULE T w1r_
HALL WICHALL 1106-4
O BARREL VAULT
KITCHEN
F 114 FChtR
171011 G.UE5T 5 w
D RDOM ® WINE
104-1
GAP.AGEin C)
E
6 EM11,111 T L
GUE5T ROOM
Wil F15 4-1
R 10 Z O CATHEDRAL CEILW.
. .....................I wic
104-21
IRWEL
AfREA WELL
-2
GARAGE L _—Au D-1
E 5
......... ..........
>
... . ..... .
L
10'4"
>
ell_
16.
3'-3", 1%2" 5'-11" 9'-4" 9'.4" 3--0' r,'-4" 5'.4" 3'-0'! '-0" Y-10"
26,
.-2. 9'-4" 22'-0'
So ri�
Engineering L
EngRLR
moxixw.FroP PAx"w
1i�� +lpunFssiq�
A
\` wwvrte
_.
07-3145
_¢ 303083
TRACT 37, WEST BUTTERMILK \
BURLINGAME RANCH
PITKIN COUNTY, COLORADO
OBSERVATION/
VENT PIPES (TYP.)
1
I/
i
I
I
1 �
14" `R,VC HEADERS -
JOB NO. 15364W
SCALE
1"=30'
PTIC FIELD ENVELOPE
1587.2 SF OF INFILTRATIVE AREA IN EIGHT
�GRAVELLESS CHAMBER -TRENCHES. EACH
TRENCH MUST HAVE ONE ROW OF 20
INFILTRATOR(R) QUICK4(TM) CHAMBERS FOR
`,. A TOTAL OF 160 CHAMBERS.
CONCRETE DISTRIBUTION
BOX WITH BAFFLE
•CLEANOUTS REQUIRED EVERY
100 FEET MINIMUM
" PVC EFFLUENT LINE
2000 -GALLON, SINGLE -COMPARTMENT,
CONCRETE SEPTIC TANK FOLLOWED BY
1000 -GALLON, TWO-COMPARTMENT,
CONCRETE SEPTIC TANK WITH
AN EFFLUENT FILTER ON THE OUTLET
?'SETBACK
TO WELL
SITE PLAN, LOCATION OF 1V � 10/18/04
PERCOLATION HOLES, AND LOCATION
OF PROPOSED OWS 0 `� REVISED FIGURE 1
TYPICAL PLAN VIEW - N.T.S.
4" PVC EFFLUENT LINE
r1OKI!`R�_TF r1ICTPIRI ITIONI POY WITH R
INFILTRATOR(R) QUICK4(TM)
GRAVELLESS CHAMBERS,
3—FOOT BY 4—FOOT EACH ----
TYPICAL CROSS-SECTION - N.T.S.
ACKFILL
4' MAX
EXTENT OF EXCAVATION
4" PVC HEADER
TOTAL - EIGHT TRENCHES
4" SDR 35 PVC
OBSERVATION/VENT PIPE
WITH CAP
' MIN. SLOPE FOR ORqINAG
E
1.5' MIN
NFILTRATOR(R) QUICK4(TM)
IL GRAVELLESS CHAMBERS,
3—FOOT BY 4—FOOT EACH
CALCULATIONS AND SPECIFICATIONS
DESIGN CRITERIA
RESIDENCE = 5 TOTAL BEDROOMS, 7000 SF
LOADING = 130 GAL/DAY/PERSON
AVERAGE LOADING = q = 1300 GPD
PERCOLATION RATE = 48 MPI
AREA = ((1.75 X 1300) X sqrt 48)/5 =3152 SF
50% REDUCTION FOR CHAMBER—TRENCHES = 1576 SF
I: •
TRENCHES MAY BE MODIFIED TO FIT
TOPOGRAPHY USING PIVOT POINTS ON
QUICK4(TM) CHAMBERS
CONCRETE DISTRIBUTION BOX - N.T.S.
T(
TRENCH SPECIFICATIONS
NUMBER OF TRENCHES = 8
LENGTH OF EACH TRENCH = 80 FEET, 20 CHAMBERS
WIDTH OF EACH TRENCH = 3 FEET, 1 CHAMBER
TOTAL NUMBER OF CHAMBERS = 160 CHAMBERS
TOTAL AREA = 1587.2 SF
DRAIN FIELD DETAILS
'VC INLET
E
SIDE VIEW
GHT 4"
VC OUTLETS
1.5'
1.0'
INLET OUTLET 6"-8"
VIEW VIEW
*MINIMUM 8 OUTLET BOX REQUIRED
TREATMENT UNIT SPECIFICATIONS
TOTAL MINIMUM CAPACITY — 1.75 X q X (30 HOURS/24 HOURS) = 2844
GALLONS
RECOMMENDATION — ONE 2000—GALLON, SINGLE—COMPARTMENT, CONCRETE
SEPTIC TANK FOLLOWED BY ONE 1000—GALLON, TWO—COMPARTMENT,
CONCRETE SEPTIC TANK WITH AN EFFLUENT FILTER ON THE OUTLET.
all
10/18/04
TRACT 37, V
BURLINGAM
PITKIN COUP`
OBS
AS -BUILT DRAWING /
JOB NO. 15364W
SCALE
1"=30'
IN EIGHT
-iES. EACH
;HAMBERS
;S.
NE
,LE -COMPARTMENT,
TANK FOLLOWED BY
COMPARTMENT,
TANK WITH
ER ON THE OUTLET
XISTING
NELL
12/22/04
FIGURE 1