Loading...
HomeMy WebLinkAboutpitkin.eh.264334300004 (2013)COU l�T T� Permit #: 0011.2013.powt JSITE WASTEWATER TREATr NT SYSTEM (OWTS) CONSTRUCTION PERMIT 76 Service Center Rd- Aspen, CO - 81611 Phone: 970.920.5070 Fax: 970.920.5374 Parcel ID #: 2643-213-08-003 Permit Issued: ®NEW CDU ❑REPAIR ❑REMODEL/ADDITION [-]TANK ONLY ❑FIELD ONLY ❑AMENDMENT Owner(s): K2 Family Property LLC Property Address: Legal Description: 1370 Owl Creek Rd Size of Lot: 21 Acres Size of Building: 14,800 Sq. Ft Detached Accessory Unit: Size of Accessory Unit: Sq. Ft. The system is designed for: '9 Bedrooms total. The game room has been counted as a bedroom and the bunk room will have 6 beds and is equal to 3 bedrooms. The exercise room and office in the master suite are not counted as bedrooms. Designed By: Schmueser Gordon M Phone #: 970-319-2886 Fax #: 970-945-0482 Project #: 2011-371.001 Dated Mailing Address: Email Address: Perc Rate: 28 mpi or 0.95 Profile Hole Depth: 8' Minimum Tank Capacity: 3375 gallons 4185 CR 154 Glenwood 10/09/2011 nas 81601 roger@structuralassoc.com Depth to Groundwater or Bedrock Minimum Absorption Area: 2274 ft2 Permit Conditions: 2' This OWTS Construction Permit is approved on the condition of compliance with the engineer design as submitted with the application and the specifications cited above. Changes must be approved by this Department and the engineer prior to construction. This system is for the main house and includes the bunk room with 6 beds (3 bedrooms total, at 2 persons/bedroom; for sizing purposes) and the game room for a total of 9 bedrooms. The office and exercise room in the master suite are not to be used as bedrooms. The sizing also includes 45 gpd to allow for future expansion for a bathroom in a barn. The system consists of sewage flowing via gravity through a 4" pipe to a 2000 -gallon concrete, single -compartment tank. The effluent from this tank them flows into a second, 1500 -gallon, two-compartment tank. A dosing pump will be installed in the second compartment of the 1500 -gallon tank and will pump effluent to an Orenco automatic distributing valve. The effluent will then be distributed to a 41'X58' (2378 ft2) sand mound soil treatment area. The soil treatment area shall be a minimum of 236 feet to any well, 186 feet to any unlined pond or stream, and 161 feet to the dry gulch, and 4 feet above the groundwater. This Permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an "as -built" letter to this Department within 30 days of the final inspection, unless a longer period of time has been agreed upon, in writing. This Department must also be called for the final inspection with a minimum of 48 hours notice. Minimum horizontal distances between components of the system and physical features shall conform to the requirements of the Pitkin County OWTS Regulation. This Permit is conditioned upon the property owner(s) providing for regular inspection, cleaning, and maintenance of the system by qualified personnel, in accordance with the manufacturer's recommendations and the requirements of the Pitkin County OWTS Regulation. Issuance of this OWTS Construction Permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail. Issuance of this permit does not imply compliance with Pitkin County building and/or land use regulations, nor guarantee issuance of building and/or land use permits. THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN COUNTY OWTS REGULATION, INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE. Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Pitkin County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built" drawing must be submitted and approved by EH before final approval of the system will be issued. Issued By:Date: 05/07/13 Expires: 05/07/2014 Installer: License #: Reactivation Authorized by: Final Approvallsssued,By � , Date: , � 9 # � I New Expiration Date: 0FeePdd oct, powi �2ot3 MEH/NRO ll ONSITE WASTEWATER TREATMENT SYSTEM (OWTS) CONSTRUCTION PERMIT APPLICATION 76 Service Center Rd • Aspen, CO • 81611 Phone: 970.920.5070 Fax: 970.920.5374 Parcel ID# (available from the Pitkin County Assessor's Office 970-920-5160 or at www.pitkinassessor.org): �l - '+-34'3`i �� _ ��' ` � Purpose of Permit: NEW ❑REPAIR DUE TO FAILURE ❑REMODEL/ADDITION [j TANK ONLY ❑FIELD ONLY Cost of System Repair or Remodel/Addition (approximate):] Contact/Applicant Mailing Address: Property Address:/ n / y � Lot: Block:Filing: Subdivision: Property Owner(s)*: . Email Address: K2 F I Owner's Mailing Ad ress: City, State, Zip: i Home Phone: B siness Phone: Contact information must be provided for the owner signing this application. Prima Contact Person/_Applicant (if not owner): Company: ` Contact/Applicant Mailing Address: Cit , State, Zip: Cell Phone: Erusiness Phone: 60(7 - ,—? Z C1 -7c, ��;j Fax Number: 67'70 -�, y5 - c x4ez- Email Address: Building Permit # (if applicable): Lot Size (in acres): / Size of Building (square feet)/ Number of Potential Bedrooms: �,✓ Detached Accessory Unit? � YESIL51 X NO Size of Accessory Unit (square feet): , Number of Potential Bedrooms In or Fixture List for the Accessory Unit: Water Source: PRIVATE WELL ❑ SURFACE WATER ❑ SPRING ❑ COMMUNITY/PUBLIC WATER SYSTEM Name of Community/Public Water System (if applicable): Engineering Firm: Job Number: Phone Number: Fax Number: Mailing Address: City, St , Zip: % >✓ % 62 PLEASE READ BEFORE SIGNING: 1 certify that the above information is complete and accurate and that I have provided complete and accurate information in all of the documents included in my application package. I acknowledge that EH/NR may revoke any permit I am issued if my application is found to contain any inaccurate, false, or misleading information. I understand that no construction may be undertaken on an OWTS until an OWTS Construction Permit is issued. Owner Signature (Required): Date: Applicant Signature Date: 3 -ii -13 FOR OFFIC NLY Received by EN/HR Staff: Fee & Receipt #: Date: 1 013. 33V)-4- PO Box 2844 Glenwood SpHngs, CO 81602 Ph 970-618-5033 alii6Fax 303.216-27% June 3, 2011 Project No. 1851 K2 Family Property C/O Cunniffe Architects At: Steve Smith 610 East Hyman Avenue Aspen, CO 81611 Subsurface Review and Planning Recommendations for Upgrade Onsite Wastewater System Kotubei Residence 1370 Owl Creek Road Pitkin County, Colorado Steve, ALL SERVICE septic, LLC conducted a percolation test for the subject property, and prepared preliminary onsite wastewater system (OWS) layouts for the proposed subject residence. The property is located outside of Aspen, CO in an area where OWS are necessary. SITE CONDITIONS A residence and several barns/sheds exist on the property. As we understand a new 7 bedroom residence, having approximately 15,000 SF is proposed. The current structures and existing OWS will be removed and/or abandoned. The property is 10.3 acres and has grassy undulating meadows. There are several drainages flowing through or next to the property which must be considered during OWS design. The property will be served by an onsite well. Based on the size of the proposed structure, the setback distance from the OWS drain field to wells is 188 feet, and the setback distance from the OWS drain field to any surface water drainage is 138 feet. A surface drainage may be lined with PVC liner and reduce setback to 10 feet. SUBSURFACE The subsurface was investigated by digging 4 percolation holes in two different areas as indicated on attached plan. Materials encountered in the percolation holes consisted of very loamy sandy clay to the maximum depth explored of 4 feet. Groundwater was encountered in Percolation holes 3 and 4 at 2 feet. Percolation rates ranged from 10 to 40 minutes per inch (MPI). A 28 MPI, or an application rate of 0.95 Gals/SF/day rate will be used to design the OWS. o CONCLUSION Onsite Wastewater System Page 2 The OWS design will based on 7 -bedrooms and an average sewage load of 1400 GPD. The installation will include a tank capacity of approximately 2500 gallons, and a drain field consisting of chambers. Secondary treatment may be added which would allow for considerable drain field size reductions. The soil investigation yielded ground water at 2 feet, therefore a partial mound must be installed. The mound may be graded such that it is `blended' in with current topography. OPTION 1 — (W1) — Utilize secondary treatment. Place drain field in one of two areas shown, depending on `lining' of water courses. OPTION 2 — (W2) — No secondary treatment. Place drain field in one of two areas shown, depending on `lining' of water courses. It should be more cost effective, based on subsurface conditions, to implement secondary treatment and install a smaller drain field. This will also reduce impact on landscape. The OWS options proposed can be constructed in the proposed activity envelope. Both options are viable. The final OWS location decision may be made in the future prior to building permit application. Construction must be according to the Pitkin County Health Department OWS regulations, the OWS Construction Permit provided by the county, and this design. LIMITS: The design is based on information submitted. If soil conditions encountered are different from conditions described in report, ALL SERVICE septic, LLC should be notified. All OWS construction must be according to the county regulations. Requirements not specified in this report must follow county regulations. The installer should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. Please call with questions. Sincerely, ALL SERVICE septic, LLC Timothy R. Petz Copy emailed to Mitch Haas Copy emailed to Cunniffe Architects Reviewed By: Richard H. C OWTS DESIGN CALCULATIONS - for Pitkin USING LTAR Owner's Name Parcel ID # House Size (sq. ft.) (75 gpd or 100 gpd) Number of Bedrooms in Main House Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House Number of Bedrooms in Detached Caretaker unit Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit (If the caretaker unit is ATTACHED, treat as if part of main house.) Average Daily Waste Flow 1800 State Review Required? no LTAR OEM (T) Design Flow (Q) = # potential bedrooms X 2 people/bedroom X gpd X 1.5 Q= 2700 L� Minimum tank capacity 3375 gallons Absorption Area (=B20 X 1.0/1317) A = Q x 1.0 loading/LTAR A = 2,842 sq. ft. of absorption area required Absorption ^ e (—Q i 5 v SQRT per- . rate) u�ru nnSECO D nv TREATMENT ENT (no leading factor) A= 2,842 sq. ft. of absorption area required Abs. Area w/ loading factor (B25) Trench Bed Quick4 Trench Quick4 Bed Pipe and Gravel 2558 2842 259 288 Dosing 2274 2274 230 230 Chambers 1989 2558 202 259 Max Allowable 1421 1989 144 202 Secondary Treatment Abs Area w/ out loading factor (1328) Trench Bed Pipe and Gravel 2558 2842 259 288 Dosing 2274 2274 230 230 Chambers 1989 2558 202 259 Max Allowable 1421 1989 144 202 236 SETBACK FROM WELL # of feet = 186 SETBACK FROM POND, STREAM OR IRRIGATION DITCH # of feet = 161 SETBACK FROM DRY GULCH # of feet = ti✓ RECEPTION#: 583810, 01104/2013 at 11:29:10 AM, 1 OF 2, R $0.00 Doc Code ADMIN DECISION Janice K. Vos Caudill, Pitkin County, CO ADMINISTRATIVE DECISION OF THE COMMUNITY DEVELOPMENT DIRECTOR OF PITKIN COUNTY, COLORADO, APPROVING THE K2 FAMILY PROPERTY LLC MINOR AMENDMENT TO SITE PLAN TO INCLUDE A BARN Administrative Decision No. �-2012 RECITALS 1. Pursuant to Section 2-20-150(b) of the Land Use Code, K2 Family Property LLC ("Applicant") has applied to the Community Development Director of Pitkin County, Colorado ("Director") to amend the Site Plan approved pursuant to Hearing Officer Determination No. 05-2011 to add a barn at the north end of the residence. The proposed barn is within the previously approved Activity Envelope. 2. The lot is located at 1370 Owl Creek Road, and more described as Parcel E, Stapleton Subdivision. 3. The lot contains 10.31 acres and is a conforming size lot in the AR -10 zone district. 4. The BOCC approved the Stapleton Subdivision via the Agricultural Lot Split Subdivision Exemption, pursuant to Resolution Nos. 83-122 and 84-116, the final plat was recorded in Plat Book 20 at Page 31. Parcel E is improved with a single family residence built in 1967, a detached garage and agricultural outbuildings. Parcel W is unimproved. 5. The Community Development Director approved building envelopes on both parcels pursuant to Administrative Decision No. 65-2006; the 1041 site plan was recorded in Plat Book 80 at Page 96. The vested rights expired on July 11, 2009. The Community Development Director approved activity envelopes on both parcels pursuant to Administrative Decision No. 47-2009: the Activity Envelope Plan was recorded in Plat Book 91 at Page 71. The 2009 approval replaced the prior 1041 approval. 6. The Hearing Officer approved Determination No. 05-2011, which granted Site Plan Review approval to construct a new single family residence, Special Review and GMQS Exemption to utilize four TDRs to develop up to 15,000 square feet of floor area, amendments to the previously approved Activity Envelope, and GMQS Exemption for a replacement residence. The Site Plan has not been recorded. 7. The Director finds that the proposed amendment complies with the applicable provisions of the Land Use Code, and will not change the use of the proposed development or the basic character of the land, is consistent with action taken during the original review, does not increase off-site impacts or the allowable floor area, and will not endanger the public health, safety or welfare. 8. The Director further finds that the proposed barn complies with the provisions of Sec. 5-20-70(i) of the Land Use Code, Floor Area Exemption for Agricultural Buildings, as follows: A. The proposed barn is designed to house field equipment for on-site haying. Administrative Decision No. -2012 Page 2 C. The parcel contains less than 20 acres, therefore, the barn is exempt from floor area up to 1,160 square feet. D. The proposed barn contains mechanical, electrical and plumbing equipment. E. The toilet room (toilet and lavatory only) will not exceed 20 square feet. F. The proposed barn will not contain any office space or human amenities. 9. The Director further finds that the barn complies with Sec. 7-20-120 of the Code, Scenic View Protection Areas, and is consistent with the development previously approved on the site. The barn is to the north of and contiguous with the approved garage and has the same height and width as the garage, so will blend with the existing structures on the site. THE DIRECTOR DOES HEREBY APPROVE the K2 Family Property LLC Minor Amendment for a barn, subject to the following conditions, which shall run with the land and be binding on all successors in interest: 1. All conditions of Hearing Officer Determination No. 05-2011 shall remain in full force and effect, except as amended herein. 2. Prior to submission of a building permit application for the barn, the Applicant shall be required to submit for approval by the County Attorney and Community Development an amended Site Plan in accordance with Land Use Code Section 2-30-20(g) and Application Manual Section 2.1.12. The above referenced approvals shall be a condition precedent to finalization and recordation of them. Prior to issuance of a building permit for the barn, the Applicant shall record an Occupancy Covenant and Agreement in a form acceptable to the County Attorney in which the Applicant agrees that the exempt floor area may only be used in association with the raising, producing, or keeping of plants or livestock, or cultivation and management of other crops or farm products, and that any area not consistent with those uses would count as floor area. The Occupancy Covenant and Agreement shall also allow the County to inspect the agricultural building at any time for compliance with the specified use limitations, subject to the provision of reasonable notice to the property owner. 4. No calculations for height, bulk, setback, size, floor area, or any other building and zoning requirements have been conducted. These requirements will be considered at the time of building permit. Any structures represented in the application may not be permitted under building and zoning regulations. 5. The Applicant shall adhere to all material representations made in the application. APPROVED by the Director, this 3Bbday of ,.,,012. Ke —;kA Aa) R Co �Q Cind ouben, Community Development Director P105-12;PID #264334300004 ...� *age RECEPTION#: 584409,11116/2011 at 02:21:17 PM, 9 OF 4, R $0.00 Doc Code DETERMINATION Janice K. Vos Caudill, Pitkin County, CO DETERMINATION OF THE HEARING OFFICER OF THE COMMUNITY DEVELOPMENT DEPARTMENT OF PITKIN COUNTY, COLORADO, APPROVING THE K2 FAMILY PROPERTY LLC SITE PLAN REVIEW, ACTIVITY ENVELOPE AMENDMENT, SPECIAL REVIEW FOR TDR RECEIVER SITE AND GMQS EXEMPTIONS Determination No.5_-2011 RECITALS 1) K2 Family Property LLC (hereafter "Applicant') has applied to the Pitkin County Hearing Officer (hereafter "Hearing Officer") to obtain Site Plan approval to construct a new single-family residence. The Applicant is requesting special review approval and GMQS exemption to utilize four TDRs to develop up to a total of 15,000 square feet of floor area. The Applicant is also requesting to amend the previously approved Activity Envelope and to obtain a GMQS exemption for a replacement residence. The parcel is within a designated scenic view protection area as seen from Owl Creek Road. 2) The property is located at 1370 Owl Creek Road, and described as Parcel E, Stapleton Subdivision. 3) The lot contains 10.31 acres and is a conforming size lot in the AR -10 zone district. 4) The BOCC approved the Stapleton Subdivision via the Agricultural Lot Split Subdivision Exemption, pursuant to Resolution Nos. 83-122 and 84-116; the final plat was recorded in Plat Book 20 at Page 31. Parcel E is improved with a single family residence built in 1967, a detached garage and agricultural outbuildings. Parcel W is unimproved. 5) The Community Development Director approved building envelopes on both parcels pursuant to Administrative Decision No. 65-2006; the 1041 site plan was recorded in Plat Book 80 at Page 96. The vested rights expired on July 11, 2009. The Community Development Director approved activity envelopes on both parcels pursuant to Administrative Decision No. 47-2009; the Activity Envelope Plan was recorded in Plat Book 91 at Page 71. The 2009 approval replaced the prior 1041 approval. The vested rights are valid until July 1, 2012. 6) The Hearing Officer heard this application at duly noticed public hearings on September 20, September 27, October 4 and October 18, 2011, at which time evidence and testimony was presented with respect to this application. 7) The Hearing Officer finds that the Site Plan and Amended Activity Envelopes comply with the applicable standards in the Land Use Code ("Code"). 8) The Hearing Officer further finds that the proposed development is consistent with the criteria for development within the Scenic View Protection Area. The residence has been sited, designed and landscaped to minimize the visual impact as seen from Owl Creek Road, 9) The Hearing Officer further finds that the use of four TDRs on the site is appropriate, given the siting of the residence, the support in the Owl Creek Master Plan for the use of TDRs for additional floor area, and compliance with the other special review criteria. 0 Determination No. -2011 Page 2 NOW, THEREFORE, BE IT RESOLVED by the Pitkin County Community Development Hearing Officer that he does hereby approve the K2 Family Property LLC Site Plan Review, Activity Envelope Amendment, Special Review for TDR Receiver Site, and GMQS Exemptions, subject to the following conditions, which shall run with the land and be binding on all successors in interest: 1. The Applicant shall adhere to all material representations made in the current or prior applications or in public meetings or hearings and shall consider those representations to be conditions of approval, unless amended by other conditions. 2. The conditions of Administrative Decision No. 47-2009 shall remain in full force and effect, unless amended by other conditions herein. 3. The Applicant shall comply with all standards for development within Scenic View Protection Areas as represented in the application and approved in this Determination. The exterior of the structures shall utilize indigenous earth tone materials or colors and the roofs shall have a non -reflective color or composition. Reflective roof materials shall not be used unless the materials are treated prior to installation to eliminate reflectivity, with the exception of materials associated with solar or photovoltaic equipment. Samples of exterior materials shall be reviewed and approved by Community Development prior to building permit application. Driveway lighting is prohibited and all other lighting shall comply with the lighting code. 4. Prior to submission of any future building permit applications for the residence, the Applicant shall be required to submit for approval by the County Attorney and Community Development a Site Plan in accordance with Land Use Code Section 2-30-20(g) and Application Manual Section 2.1.12. The above referenced approvals shall be a condition precedent to finalization and recordation of them. Prior to recordation of the Site Plan, the Community Development Department shall conduct an evaluation to determine if the resulting land use or character of the land is or will be essentially and primarily residential, commercial, or another use or character other than agricultural, and, thereby determine if a covenant prohibiting commercial agricultural activity shall be required. The Community Development Department's determination shall be memorialized in an Administrative Decision. 6. The lot is exempt from Growth Management for up to 5,750 square feet of floor area. At building permit application for the new residence, the Applicant shall surrender four TDR Certificates and a copy of the deed(s) evidencing the Applicant's acquisition of the Certificates (if applicable), in order to develop up to 15,000 square feet of floor area. 7. The property line of Parcel E is within '/z mile radius of the Buttermilk Metro District's service area. Therefore, prior to submission of building permits for the residence, the Applicant shall comply with Sec. 7-50-20(c)(2) of the Code. 8. Prior to issuance of building permits for the residence, the Applicant shall: A. Provide proof of an adequate water supply (in terms of quantity and availability) for domestic and fire protection purposes, and for irrigation purposes, if applicable. B. Complete a fireplace/woodstove registration form with the Community Development Department, if necessary. Determination No. 'S_-2011 Page 3 C. Obtain a County access/driveway permit for any major improvements to the driveway, which shall be reviewed and approved by the Aspen Fire Protection District and Planning/Zoning. D. Submit a drainage and erosion control plan for review and approval by Planning/Zoning. If the total development disturbs one (1) acre or more, the Applicant shall apply for and obtain a State Stonnwater Permit. All historic and natural drainage patterns shall be maintained. Stormwater shall be detained onsite and allow infiltration of runoff prior to discharge. E. Submit a construction management plan for review and approval by Planning/Zoning. F. Pay the applicable road and employee housing impact fees. G. Obtain an On -Site Wastewater Treatment System construction permit from Environmental Health. Secondary treatment is encouraged due to high ground water conditions. The drainage ditch adjacent to Owl Creek Road shall be lined or converted in order to meet minimum setbacks to the proposed absorption area. H. Submit a detailed revegetation plan for disturbed areas with appropriate seed mixes. The plan shall specify the native seed mix to be used, the rate at which it will be applied and the method of cover. 1. Submit a tree mitigation plan for the removal of any trees larger than 6 inch DBH. J. Submit a detailed landscaping plan. K. Submit a detailed exterior lighting plan. 9. The Applicant shall submit an earthmoving permit for the pond and water features, for review and approval by Planning/Zoning, Verification of adequate water rights shall be provided. The permit application shall include engineering for all overflow and outlet structures, recirculation systems, etc. If the pond is to be stocked with fish, the Applicant shall obtain a private lake license and stocking permit from the DOW. The pond can only be stocked with certified whirling disease free fish. 10. Landscaping shall be substantially consistent with the landscaping shown on the site plan. Areas disturbed by construction shall be re -vegetated within one growing season of the project's completion. Landscaping shall be completed prior to issuance of the Certificate of Occupancy for the residence. 11. No development in excess of 30" above or below natural grade shall occur within the setbacks of the lot, with the exception of driveways and associated retaining walls of up to 6' above or below natural grade and fencing. Landscaping in the form of berms shall not exceed four feet from the most restrictive grade. Any development located within setbacks mandated by County zoning regulations that does not comply with these restrictions shall require a variance from the Board of Adjustment. Approval of an activity envelope within such setbacks does not assure approval of a variance. 12. The Applicant shall comply with all of the codes and requirements of the Aspen Fire Protection District, including but not limited to access, turning around of fire apparatus, installation of approved fire sprinkler systems in all structures, and a minimum 20,000 gallon water supply for fire fighting or confirmation of an accessible hydrant in the vicinity. 13. No development shall occur outside of the approved activity envelopes, with the exception of vegetation removal necessary to comply with the wildfire mitigation measures described above. 14. The Applicant shall provide adequate engineering of any retaining walls over 4' in height and/or any improvements to retaining walls over 4' in height. All retaining walls shall be a maximum of 7' in height. 0 Determination No. 5-2011 Page W 15. Prior to commencement of any earthmoving or other construction activity, the Applicant shall stake the corners of the activity envelope and install construction fencing around the construction site within the perimeter of the activity envelope. The fencing shall remain in place until issuance of a Certificate of Occupancy. 16. No calculations for height, bulk, setback, size, floor area, or any other building and zoning requirements have been conducted. These requirements will be considered at the time of building permit. Any structures represented in the application may not be permitted under building and zoning regulations. 17. Failure to comply with the conditions of this approval may result in revocation of this approval, or any subsequent permit(s) or approval(s) related to this property, or vested rights associated with this property. 18. Statutory vested rights for the approval contained herein are granted pursuant to the Pitkin County Land Use Code and Colorado Statutes, subject to the exceptions set forth in Pitkin County Land Use Code, § 2-20-170 and C.R.S., § 24-68-105. The statutory vested rights granted herein shall expire on C)'J(j)er- 1',�' 2014. NOTICE NOTICE OF PUBLIC HEARING PUBLISHED IN THE ASPEN TIMES WEEKLY on the 10 day of August, 2011. APPROVED AND ADOPTED this 18'h day of October, 2011. PUBLISHED AFTER ADOPTION FOR VESTED REAL PROPERTY RIGHTS in the Aspen Times Weekly on the -_�a day of C r 2011. ATTEST: Bonnie WaechtIer, Administrative Assistant APPROVED AS TO FORM: John Ely, Cou y P050-11;PID##264334300004 COMMUNITY DEVELOPMENT DEPARTMENT HEARING OFFICER OF PITKIN COUNTY, COLORADO By $C - James R. True, Hearing Officer Date o /12 —" ' APPROVED AS TO CONTENT: u� Cindy Houben, Community Development Director 11iflliillliilllliililfililll{Ili �_��-��ry�t:^�_ illlliililllilliil JANICE K VOS CAUDILL PITKIN COUNTY CO R 0.00 D 0.00 ADMINISTRATIVE DECISION OF THE COMMUNITY DEVELOPMENT DIRECTOR OF PITKIN COUNTY, COLORADO, APPROVING THE STAPLETON 1041 HAZARD REVIEW Administrative Decision No.2006 RECITALS LLZP Elizabeth and Sam Stapleton Family, ("Applicant') has applied to the Pitkin County Community Development Director ("Director") for 1041 Hazard Review approval to establish building envelopes on two lots, within which to construct new single family residences. The envelope on Parcel E encompasses the existing residence and outbuildings; the envelope on Parcel W would replace the "Proposed House Site" on the Plat. 2. The lots are located at 1370 Owl Creek Road, and are described as Parcels E and W, Stapleton Subdivision. 3, The property is zoned AFIZ14 Parcel E; contains 10,3068 acres and Parcel W contains 10.0294 acres, 4. The BOCC granted General Submission and Detailed Submission/Final Plat approval for the Stapleton Lot Split pursuant to Resolution Nos. 83-133 and 84-116. The plat was recorded in Plat Book 20 at Page 3 ] The_lots are,exp pt. from growth management up to 5,750 square.feet of floor area, as they were.approved by tfie BOCC, prtorao.June,1.9,;Q99,,pursuant to Sec 9-] 1Q-Q51(A). 5. The Applicant submitted a complete application prior to July 6, 2006, therefore, the application is being considered pursuant to the 1994 Land Use Code, as amended. 6. The Applicant provided notice of the application to the adjacent property owners, as required pursuant to Section 5-80-010(J) of the Land Use Code ("Code"). No objections were received within 30 days from the date the notice was postmarked (June 1, 2006). W 7. The Director finds that the wildfire;.hazard within the envelopes is rated as low and can be mitigated; that the envelopes are located on slopes- of less than 15%i.and that the property is not within any mapped wildlife: habitat areas. THE DIRECTOR DOES HEREBY APPROVE the Stapleton 1041 Hazard Review, subject to the following conditions, which shall run with the land and be binding on all successors in interest: I . Prior to submission of any building permit applications for new development, the Applicant shall a submit a 1041 Hazard Review Site Plan to the Community Development Department for approval and recording. The mylar copy of the site plan must be signed by the owner prior to submittal for recording. The site plan shall be amended as follows_ A. Eliminate the reference to the "Proposed House Site" on Parcel W. B. Clarify the delineation of the parcel lines and the building envelope boundaries. 2. Prior to submission of an ISDS permit for a residence on Parcel W ora replacement residence on Parcel E, the Applicant shall provide documentation to the Environmental Health and Natural Resources Department as to an adequate quantity of water. l 526617 1� Pa9e t of 4 1 @7/14/2006 03:251 �ti 11 �I @ 11 SII I� I� �Na u TY Il o JANICE K VOS CAI1diL4 TKI N c P I 526728 Administrative Decision No, &5--20061111111111111111 11111111111111111 I� 0ge: fPa e 2 IN1Ili `ai2eo02:48'- JANIRNIC£ K VOS CRUDSLL. PITKIN COUNTY CO E2 0,00 D 0.00 3. Prior to issuance of any building permits for a residence on Parcel W or a replacement residence on Parcel E, the Applicant shall: A. Complete a fireplace/woodstove registration form with the Community Development Department, if necessary. B. Obtain a County access/driveway permit to improve or construct the driveway, if applicable. C. Submit a drainage and erosion control plan for review and approval by the County Engineer, D. Submit a construction management plan for review and approval by the County Engineer showing the locations of staging, material stsage and employee and construction traffic parking. Er Pay the applicable road and employee housing ippact fees, F. Obtain approval of a septic permit from the Enyironmental Health Department. The septic system shall be located within the approved building envelope, and must comply with the setback requirements from surface and groundwater sources. 4. Prior to commencement of any earthmoving or construction activity, the Applicant shall stake the corners of the building envelope and install construction fencing around the perimeter of the envelope. The fencing shall remain in place until a Certificate of Occupancy is issued for the residence, 5. The Applicant shall comply with the following landscaping and wildfire defensible space mitigation standards: A. Brush, debris and non -ornamental vegetation shall be removed within a 10' perimeter of all structures. B. New conifers shall not be planted within 15' of existing or new structures, C. The Applicant shall be responsible for the continued maintenance of the defensible space vegetation requirements. 6. The Applicant shall comply with the following additional wildfire mitigation standards: A. Roofs shall be constructed with a Class A roof covering or a Class A assembly as defined in the International Building Code (TBC) Section 1505.2. Wood shake/shingle roof coverings are prohibited. Roofs with less than a 3:12 pitch are not permitted unless they comply with the following: 1) All roof coverings shall be noncombustible materials and installed on a Class A roof assembly. 2) All roof coverings shall have a surface that shall facilitate the natural process of clearing the roof. 3) All roof designs shall facilitate the natural process of clearing roof debris. Protrusions above the roofline, such as parapets, shall be prohibited. 4) Roofs shall be installed as required by the adopted building code and shall have a minimum slope of 1:48. 5) All roof designs, coverings, or equivalent assemblies shall be specifically approved by the Fire Marshal prior to submittal of a building permit application, B. Vents shall be screened with corrosive resistant wire mesh with mesh '/4 inch maximum. C. Roofs and gutters shall be kept clear of debris. D. Yards shall be kept clear of all litter, slash, and flammable debris. 1526517 PI 1Page: 2 of 4 0 7/I43flNICE K t� VOS CRUDI�PITKIN COUNTY CO R 0.0.00 D20 00 � 25, 11111111111111111111111111111111111111111111111111111�ge:3ofAdministrative Decision No. -20D6 07/21/2006 02:48F Page 3 JANICE K VOS CAUDILL PITKIN COUNTY CO R 0.00 D 0.00 E. All flammable materials and firewood/wood piles shall be stored on a parallel contour a minimum of 15 feet away from any structure. F. Weeds and grasses within a 30 foot perimeter of all structures shall be maintained to a height of not more than 6 inches. G. Swimming pools or ponds shall be accessible to Fire Department vehicles. H. Fences shall be kept clear of brush and debris. 1. Wood fences shall not connect to the structure. J. Fuel tanks shall be installed underground with an approved container. K. Propane tanks shall be installed according to NFPA 48 standards and on a contour away from the structure with standard defensible space vegetation mitigation around any above -ground tank. Any wood enclosure around the tank shall be constructed with materials approved for 2 hour fire - resistive construction on the exterior side of the walls. L. Each structure shall have a minimum of one 10 pound approved ABC fire extinguisher placed in a visible and accessible location. M. Addresses shall be clearly marked with 2 inch non-combustible letters and shall be visible and installed on a non-combustible post. N. New utility lines shall be buried within the driveway. 6) The Applicant shall comply with the following measures to mitigate impacts to wildlife: A. Native vegetation shall be maintained outside of the activity and access envelopes. B. Provide waste storage that complies with the County's Wildlife Protection Ordinance, C. Avoid fruit -bearing trees and shrubs in any landscaping. D, Fencing outside of the building envelope must comply with the wildlife fencing standards in the Code. 7. No development,iricluding,_grad ug,. excavation, fll placement, berming, landscaping, vegetation removal or disturbance, entry or ranch gates, well or septic system shalfoccur oufslda of the 'approved buildtngenvelope.�_ 8. All areas disturbed by construction steal l be revegetated to limit water consumption and additional runoff within one growing season after completion of construction. 9. The Applicant shall comply with the applicable codes and requirements of the Aspen Fire Protection District, including but not limited to fire department access, turning around of fire apparatus, an approved fire sprinkler system and water supply. 10. Failure to comply with the conditions of this approval may result in revocation of this approval, or any subsequent permit(s) or approval(s) related to this property, or vested rights associated with this property. 11. The Applicant shall adhere to all material representations made in the application and shall consider those representations to be conditions of approval, unless amended by other conditions, Illi ( 52651 7 11 II Page: 3 of 4 Ill ` I llll� Mi Illy f Ill�l 07/14/2006 Il II IN llll 03.25E JRNICE K VOS CAUDILL PITKIN COUNTY CO R 0.00 D 0.00 LM .Administrative Decision No&6—�-2006 Page 4 !!11lI�IIlIliIIH! 5272 Page: 4 of R 07/21/2006 02:48F JRNICE K VO5 CRUDILL PITKIN COUNTY CO R 0.00 D 0.00 12. Statutory vested rights for the approval contained herein are granted pursuant to the Pitkin County Land Use Code and Colorado Statutes, subject to the exceptions set forth in Pitkin County Land Use Code, § 4-140 and C.R.S., § 24-68-105. The statutory vested rights granted herein shall expire on 2009. APPROVED by the Director, thisJj -4 ,,day of 2006. PUBLISHED AFTER ADOPTION FOR VESTED REAL PROPERTY RIGHTS IN THE ASPEN TIMES WEEKLY ONR]_� -9�Lx LL ' Cindy frouben, Community Development Director P0I37-06 PIDR264334300004 & 264334300005 llllillllll� 17 : 4 of 4 Illy«l 1�11111�1! } 1 JRNICE���IIIllllll K VOS CRUD VIII 07/14/20 iLL pITKIN COUNTY CO 06 03.25E R 0.00 D 0.00 ADMMSTRATIVE DECISION OF THE COMMUNITY DEVEi,OPAjENT DIRECTOR OF PITXtN COUNTY, COLORADO, APPROVING THE SAM AND ELMABETII STAPLJE;TON FAMILY LLLP ACTIVPI'Y ENVELOPES Administrative Decision No.q---2009 RECITALS 1. Sam and Elizabeth Stapleton F'amUy LLLP (°'Applicant") has applied to the Pitkin County Community Development Director ("Director') for approval. to establish activity envelopes on two Jots, within which to construct new single farnily residences. Thc.activty,egvelopesaee. slightly expanded from the envelopes approved in 2006. 2. The lots are located at 1370 Owl Creek Road, and are described as Parcels Band W, Stapleton Subdivision. Parcel -l3 is improved with a single t"elniiy..residence and agcuitu�ai.ogtbuildings; Parcel... 3. no property is zonedmAR-10 Parcel E contalns 10.3048 acres and Patrol W contains 10.02% acm 4. The BOCC granted General Submission and Detailed SubmissiowFinai Plat approval for the Stapleton Lot Split pursuant to Resolution NOS, 83133 and 84116. The plat was recorded in Plat Boots 20 at Page 31. The Joss _are�cxempt #mm growth_ management. up to.6,7,.S0;sggare fist of floor area, as they. •were approved. by the T3bCC prior to June J 9, 20011, pursuant to Sec Q:1 � it 051(A). 5. The Community Development Director granted 1041 hazard review approval, pursuant to Administrative Decision No. 65-2006. The,1041 site plan is recorded in Plat Book 80 at Page 96.. The vested rights expire on duty 11, 2009, 6. Tho Director finds that tiie wildfire. hazard within the.enYelgpes is rated as low and can be mitigated;__ that the enveb eS are located o» slopes --- P open of less share 1 S%arid chat the property is not within any_ mapped wildlifea6dat arm, THE DIRECTOR DOES HEREBY APPROVE the Sam and Elizabeth Stapleton Family LLLP Activity Envelopes, subject to the•followingconditions, which shall run with the land and be binding on all successors in interest: 1. The Applicants shall adhere to all material representations made during the application process. Z Prior to submission of any building or other development permit applications, the Applicant shalt he _ required to submrt farapprpva! an application for SIit lan_)teview, pursuant #q,Secs 2 3Q 20 and i:0-50 of the Code,• The Site Pian Review application shall address the following, in addition to the A14q@rements specified above: A. Demonstrate compliance with the standards In See. 7.20-120.4 for develop ment,within the x Memo Vrew Proteetlon Area and the rural character guide Ines for burlc[i»g .locatrorr R Sec.,.7 20 l20�is of khe GAs)e B. 15emonstrate ihaf the site can accommodate an on -Site wastewater treatment system (OWTS) that complies with the then current OWTS regulations. RECEPTIO NP-: 660698, 07/0912009 at 02:07:33 PM, I on d, R $0.00 Doc Code ADMIN DECISION Janice K. Vos Caudill, Pitkin County, CO E Administrative recision No."T 2009 Page 2 C. Demonstrate that a driveway can standards. be constructed in compliance with the County's driveway 3. Prior to submission of the Site plan Review application, the Applicant shall be required to submit for approval by the County Attorney and Community Development Director an Activity Envelope plan in accordance with Und•Use Code Section 2-30-20(g) and Application Manual•Section 2.1.1. The above referenced approvals $hail be a condition precedent to finalization ind-recordation, 4. Each lot is exempt from growth management up to 5,756 square feet of gross floorarea without the use - of TDR$ or growth management alfotrmonts for additional floor area. S. Prior to issuance of any building permits for a residence on Parcel W or a replacement residence on Parcel 13, the Applicant shall., A. Provide proof of an adequate water supply (in terms of quantity and availability) for domestic and fire protection purposes, and for irrigation purposes, if applicable. B. Complete a fireplace/woodstove registration form with the Community Development Department, if necessary, C. Obtain a County accessfdriveway permit to improve or construct the driveway, if applicable. D. Submit a drainage and erosion control plan for review and approval by the Coty Enungineer. E. Submit a construction management plan For review and approval by the County Engincor showing the locations of staging, material storage and employee and construction traffic parking, F. pay the applicable road and employee housing impact fees. G..Obtain•an on-site wastewater disposal system permit from the Environmental Heafth and N Resources Department, ahuraE Prior to commencement of any_ earthmoving or construction activity, the Applicant shall stake the corners of the activity envelope and install construction fencing around the perimeter ofthe envelope. The fencing shall remain in place until a Certificate of Occupancy is issued for the residence. 7. The Applicant shall comply with the following landscaping and wildfire defensible space mitigation -standards- A. Brush, debris and non-orname structures. ntal vegetation shall be removed within a l0' perimeter of all B. New conifers shah not be planted within 15' of existing or new structures. requirements. C. The Applicant shall be responsible for the continued maintenance of the defensible space vegetation 8. The Applicant shall comply, with the following additional wildfire mitigation standards; A. Roofs shall be constructed with a Class A roof covering or a Class A assembly as defined in the international Building Code (IBC) Section 1505.2, Wood shake/sitingle roof cove rings are prohibited. Roofs with less than a 3:12 pitch are not permitted unless they comply with the following- 1) All roof coverings shall be noncombustible materials and installed on a Class A roof assembly. Administrative Decision No. �R-2004 Page d 2) All roof coverings shall have a surface that shall facilitate the natural process of clearing the roof, 3) All roof designs shall facilitate the natural process of clearing roofdebris, Protrusions above the rooflinc, such as parapets, shall be prohibited. d) hoofs shall be installed as required by the adopted building code and shall have a minimum slope ofIAg. S) Ali roof designs, coverings, or equivalent assemblies shall be specifically approved by the Fire Marshal prior to submittal of a building permit application. B. Vents shall be screened with corrosive resistant wire mesh with mesh 114 inch maximum. C. Roofs and gutters shall be kept clear of debris, D, Yards shall be kept clear of all litter, slash, and flammable debris, B. All flammable materials and firewood/wood piles shall be stored on a parallel contour a minimum of IS feet away from any structure, F. Weeds and grasses within a 30 foot perimeter of all structures shall be maintained to a height of not more than G inches. a Swimming pools or ponds shall be accessible to Fire Department vehicles. 11. Fences shall be kept clear of brush and debris. L Wood fchces shall not connect to the structure. I. Fuel tanks shall be installed underground witli an approved container. K. Propane tanks shall be installed according to NFPA 48 standards and on a contour away from the structure with standard defensible space vegetation mitigation around any -above -ground tank, Any wood enclosure around the tank shall be constructed with materials approved for 2 hour fire - resistive construction on the cxierlor side of the walls. L. Each structure shall have a minimum of one 10 pound approved ABC fire extinguisher placed in a visible and accessible location. M. Addresses shall be clearly marked with 2 inch tion -combustible letters and shall be visible and installed on a non-combustible post. N. Now utility lines shall be buried within the driveway. 9. The Applicant shall comply with the following measures to mltigato impacts to wildlife; A. Native vegetation shall be maintained outside of the activity and access envelopes. B. Provide waste storage that complies with the -County's Wildlife Protection Ordinance. C. Avoid f6it-bearing trees and shrubs in, any landscaping. D. Fencing outside of the building envelope must comply with the wildlife fencing standards lo tho Code, 1D'No development, including, grading, excavation, rill placement, berming, landscaping, vegetation removal or disturbance, entry or ranch gates, well or septic system shall occur outside of the approved activity and,access envelopes. I 1. All areas disturbed by construction shall be revegetated to limit water consumption and additional runoff within one growing season after completion of construction. (60 AdmInistrarive DeeisiwMo. 7_2009 Page r 12. The Applioant shall comply with the applicable codes and requirements of the Aspen Fite Protection District, including but not limited to tire department access, turning around of fire apparatus, an approved fire sprinkler system and water,supply. 3. Failure to comply with the conditions of this approval may result in revocation of this approval, or any subseq went Permit(s) or approval(s) related to this property, or vested rights assaciated with this property. 14. Statutory vested rrghts for the approval contained herein are granted pursuant to the Pitkin County Land Use Code and Colorado statutes, subject to the exceptions set forth in Pitkin County Land Use Code, § 41 140 and,CA.S.,}§ 24.68.16. The statutory vested rights granted herein shall expire on APPROVED by the Director, this A -day of _, 2009, PUBLISHED AMR T ADOPTION FOR VESTED REA)C, PROPERTI' RIGHTS i[Y EiE ASPEN 1MES WEEKLY Ol�l„ i i J Z C3 Cinoyflouhen, Commun[tyl?eveloCSp7mNenit�bfirector P042-09 P'D#264334300004 &.264334300005 Scott C. Miller* PATRICK I MILLER I KROPF Attomeys at Law wwwwaterlaw.com shareholder December 6, 2011 miller -C waterlawcram replt to rlsl)t tt ailacc Mr. Charles Cunniffe 'licensed in CO Mr. Jim Kehoe Charles Cunniffe Architects 610 East Hyman Avenue Aspen, CO 81611 Re: K2 Building Permit Application for Parcel E, 1370 Owl Creek Road; Compliance with Section 7-50-20(c)(2). Dear Charles and Jim: You have asked me to address the above referenced County Code provision as it relates to the building permit application being submitted for K2 on Parcel E. 1. Public water service is not available to this Property. Main Office: 730 E. Durant Avenue The Code provision states that "...the County may require that Suite 200 development connect to a public system if service is available...." Here, public Aspen, CO 81611 service is not available. First, Parcel E is not within the taxing boundaries or the T. 970.920.1028 service area boundaries of the Buttermilk Metropolitan District as defined in the F. 970.925.6847 District Service Plan approved by Pitkin County and the District Court of Pitkin Denver Office: County during the District's formation process. Therefore, any public service to 999 18th Street this Property requires a change to the District's Service Plan which must be 30th Floor approved by the Pitkin County Board of County Commissioners pursuant to Denver, CO 80202 Pitkin County Resolution No. 188-2000; and which can be enjoined by the T. 303.893.9700 District Court. F. 303.893.7900 Nor can the District compel this property to connect to the District. By Phoenix Office: statute [C.R.S. 32-1-1006(1)(a)(II)] a Colorado Special District has no power to 2415 E. Camelback compel connection if the owner's property is outside of the District boundaries. Suite 700 Phoenix, AZ 85016 This statute is intended to protect the property owner against involuntary forced T. 480.921.4044 inclusion and taxation. 1. 480.921.8688 Moreover, the City of Aspen now provides water to the District pursuant Tulsa .63r ' to Bulk Sale Water Service Agreement, dated January 14, 2011. As it currently 7633 E. 63rd Place stands, this Agreement does not authorize any increased service to Parcel E.1 In Suite 300-18 Tulsa, OK 74133 T. 918.459.4634 The Agreement does recognize there is current service "extraterritorially" to the existing, old (. 970.925.6847 Stapleton home, but specifically does not allow increased usage above existing use. a professional corporation CADmuments and Settings\—\Local SettingsUempomry Intemet Files\OLK112\Qmnitre Ltr for County submittal 11-28-1I.doc • i PATRICK I MILLER ( KROPF Charles Cunniffe Architects Page 2 December 6, 2011 addition, the City must approve any change to the District "service area." During the Agreement negotiations, the City was opposed to any increased service to Parcel E through the District/City water system. 2. Environmental impacts would be greater by connecting to the District/City public system. The City supplies water to the District through a "master meter" tap which is located by the Airport. The District then needs to pump this water in a pressurized system uphill to serve the uses in its service area. The energy costs to pump and lift this water uphill and service Parcel E are far greater than the pumping costs in an individual well located within feet of the residence. In addition, the City water comes from direct diversions out of Maroon and Castle Creeks, surface sources which are over appropriated and subject to many competing uses, including environmental instream flows held by the Colorado Water Conservation Board. The proposed well water for Parcel E will come from the underground aquifer tributary to Owl Creek. The K2 well will largely utilize recharge water from ditch irrigation diversions which will occur with or without the well, i.e., any well diversions are primarily a "successive" use and re -use of the deep groundwater percolation and return flows from irrigation. Considering these factors, it is arguable that connection to the District/City water system causes more environmental impact than using an individual on-site well. 3. State law allows for an exempt well permit in this situation and K2 is entitled to rely on such permit. K2 is vested with an "exempt" well permit for Parcel E, issued pursuant to C.R.S. 37-92-602. Issuance of an exempt well permit is, by definition, a determination that "other water supplies are not available" to this Property since such exempt permit could not be granted otherwise. Required connection to a nearby (but out -of -boundary) public provider is inconsistent with the State statute and policy allowing for reliance on an exempt well permit in this scenario. In conclusion, we believe K2 has complied with Section 7-50-20(c)(2). Connection to the District/City public system is not required because service is not available to Parcel E and any such requirement would be contrary to State statutes which allow exempt well permits and prohibit compelled connection in this situation. Moreover, the basis for requiring such a connection under the Code (i.e., less environmental impact) is not present here. PATRICK I MILLER I KRQPF Charles Cunniffe Architects Page 3 December 6, 2011 Very truly yours, PATRICK, MILLER & KROPF, P.C. A Professional Corporation By: ;At�'Z Scott C. Miller millerawaterlaw. com SCM/scm encl. cc: Leonard Oates, Esq. Mitch Haas t5SGM www .sgm inc.com November 20, 2015 PITKIN COUNTY ENVIRONMENTAL HEALTH Attn: Kurt Dahl 76 Service Center Road Aspen, CO 81611 RE: OWTS Certification of Installation K2 Ranch, 1370 Owl Creek Road, Pitkin County CO, Parcel ID #264334300004 Pitkin County Environmental Health and Natural Resources Department: This letter is intended to fulfill the Pitkin County requirements for the certification of construction of the Onsite Wastewater Treatment System (OWTS) for the K2 Ranch property located at 1370 Owl Creek Road, Pitkin County, CO. This work was completed under Pitkin County Onsite Wastewater Treatment System (OWTS) Construction Permit No. 0011.2013.powt. The observations made by SGM of the OWTS installation have been completed pursuant to plans and specifications prepared by SGM. SGM conducted a site visit on 9/11/2013 to observe installation of the sand mound, pipe and gravel distribution system, automatic distributing valve and flushing assemblies. SGM conducted another site visit on 11/17/2015 to observe operation of pumps and ensure installation of controls and alarms. Due to changes in architectural and plumbing design, it was not possible to get the wastewater to flow to the septic tank via gravity. Thus, a concrete lift station with duplex grinder pumps was added between the house and first tank. Other installed components included a 2,000 gallon septic tank followed by a 1,500 -gal two-compartment septic tank with duplex effluent pumping system, piping to the automatic distribution valve, absorption field piping, and the sand mound system with pressure distribution laterals and flushing assemblies. The control panels and alarms were installed within sight of the system, including strobes, and were connected to the house's central control and alarm system. The attached record drawings show the installation of the system was generally completed per plan. As -built survey points were obtained by SGM and are provided on the plan with GPS coordinates for critical design elements. The intent of this letter, along with the attached record drawing, is to provide adequate information to convey that the installation of the OWTS improvements for the K2 Ranch property were 1:\2011\2011-371 Kotzubei�A_Corresp\PitCo_OWTS_Cert_Letter-K2Ranch.doc GLENWOOD SPRINGS 118 West Sixth St, Suite 200 1 Glenwood Springs, CO 81601 1 970.945.1004 November, 20, 2015 Pitkin County Environmental Health OWTS Certification Letter Page 2 ;SSG M www.sgm-inc.com completed pursuant to the approved plans and specifications prepared by SGM. Please feel free to contact me if I may provide further information or provide you with copies of any of the photographs that were taken during the site visits by SGM. Very Truly Yours, SGM Matthew T. Webster, Engineering Manager cc: Structural Associates Charles Cunniffe Architects o. 26078 ,"aNAL E Reviewed by: ``"NZSSS� Jay Hammond, P.E. Principal, Aspen Office -,w +' AC olt]fRp/ ser. ro weva+r.. tv 1 �.,� � ��! � � � f � auv rrousE ✓"� � / rx rms vmm ,mRs "+�. �v „�� a / r 1 r 1 - A,,.��''�w l f r. n[c L,x.nais sxw rrsrµc ✓>KJ�s sr«+wx ew r[.w ca£ axw,>,rewrr. "' i r } `- ',i9 r�I \ � / eex.azt2 2�ntC1 � a� caY� rMe ulNJrr /+cm"nrnav rnulm cr � / x+a[ umrrr ouwnres ro HE EKSe�i ax smn sc'°L�Law�srs 1 x'• - ••�''+ `� ' J. E[ecr+c nc[ aro rets+vue e:�rr evsutuuays m er aMc rN 1 `% Lw.aev ..a I ,+z�"� FJ //� snercr <ccaroa ce' wmi i �nwawr .r£awc£ters wrr aEnvs: m X` • �:'. �u[Lrr r5£r sce, wild _%�- �-+�°�--� ,i�°9 f ; �y+� � weer arJ. w,t-aE cawrcra scmEN ✓rnm coxwrr Wa^✓rrarEm�,w, � ' t4.�yWe � � � j rr•s, m xnure�aaxrs: carr �wvw.r� s+rwmr cewcr ro rixsu i \ 1 ! wnr a £ w ne o •re c wnM as cam wm ne u2.rn w' �• i`� %o.+rxa- eD[asss F.n r�ewnrz:msxx .un scxora. reewwn!nav r y � i � r l 1 rx nr£ ✓rutrr cawxv[Es. k �' r ne 4r °a \: .. i I i s ctwavea ✓rrurr rxfrxw .:w ec smxa srr ro u+rcrr xaw .¢�c[w_-Nr �• �• '� 1 / G � % � t ,x+r,) e.Ex..«r=.sm" rrz� a� r�or � � w.rfxcvs. ° cawxmr w5 t[urxw spe szEe+r�• A+r R�+g rsw,xs. �,., f f� + r f cavravrae n Resw.stae sw me assaunmzv /aur rror wFnru£J os j 1, u. a£rnmD .L•cmru[. ewus scwr a.rav L� .war s*w+sstE fzw KOf3'rMJ �'L M6:A[[AIKIVC �\��fx ,$wFR .1 �1/ � � i a. UMW CON1Id1ClDH EAGMN,G UTA.. IRt]tar AMS MS%Nl PoC GAWrY \� \ JB?Y CtlNHrNY NYL QNYN,t' N sISKCI1tYf J' a4j YCAk J ' -} = _ / ��\ ` \ /. j j (! j �l �`ixirrrn wvn�-as. r'�"'im>"£s`• moi' xw �i�vNr s -- - r� 1' �ewr£wvs ,4m erei. R+nr scxEauieL[Lxrn srianrnre+crae ' �, -, \ % urarrr outs n n,[ . onrxn cewaar. /r ! i P 1/�ttt �~ -- r L a. £oa crrxuear a c,.s tewrs aw sER[xrs: cwmuervx rs sum rr t+[s Mws°s"s"rr`r c0p1rra�.abex � � .� �� �a�rzus�sae a� exvrre�.vEau«Ea aswn�°''sizs srm � xmre wna"�i`cr srece u�ra- tt�rv- .uf ! r fwa�m o cx. a!re» ro wmuurc sec,.rvnui-rron ra mru xE t suv attMtn �' ! / Yy0!A swcx;,w£s IN! �07 f LMS AEViI tlln,+relr,a� �\, LMf, r<r p, UIKYfD ro MYSSE � , ' ,';:.. { 4 A1lGTMW ARA Rl1 Ab fill(/ gICMAO - (°° Y —A4— /` ) •.. \, " SCHMUESER GORDON MEYER llra arG,H �,_" ,� D.S e w en s.eee . 5— zoo JU S v (970) oo0 -1 « 4t. eo.oA.,r,o e r eo i A—., 45-1004 70102"727594e PITKIN COUNTY, CO Record Drawing S SCMMUESER� OORDON � MEIER AS'ee, C0.onNon L9]O� 925C]2] r( 6urrrweoe. CO 19]01 641.5355 2!4 06Y75 LAT/RUDE/LONGITUDE w zw res un* -- K xew n�.crsrc Enr aura -aan+ � - _ _ -.c.. ---- Nrw tEtsnuxt2wxe ry ur+: mss,,,, rm aur.�o-rr.nva ,.,sas. ars rt,.. ......__—.,...__...� rswY w+n ....._._-..e-._ -._.._ ra avara.-roa•+.w ,Durr 4nunrr -,w +' AC olt]fRp/ ser. ro weva+r.. tv 1 �.,� � ��! � � � f � auv rrousE ✓"� � / rx rms vmm ,mRs "+�. �v „�� a / r 1 r 1 - A,,.��''�w l f r. n[c L,x.nais sxw rrsrµc ✓>KJ�s sr«+wx ew r[.w ca£ axw,>,rewrr. "' i r } `- ',i9 r�I \ � / eex.azt2 2�ntC1 � a� caY� rMe ulNJrr /+cm"nrnav rnulm cr � / x+a[ umrrr ouwnres ro HE EKSe�i ax smn sc'°L�Law�srs 1 x'• - ••�''+ `� ' J. E[ecr+c nc[ aro rets+vue e:�rr evsutuuays m er aMc rN 1 `% Lw.aev ..a I ,+z�"� FJ //� snercr <ccaroa ce' wmi i �nwawr .r£awc£ters wrr aEnvs: m X` • �:'. �u[Lrr r5£r sce, wild _%�- �-+�°�--� ,i�°9 f ; �y+� � weer arJ. w,t-aE cawrcra scmEN ✓rnm coxwrr Wa^✓rrarEm�,w, � ' t4.�yWe � � � j rr•s, m xnure�aaxrs: carr �wvw.r� s+rwmr cewcr ro rixsu i \ 1 ! wnr a £ w ne o •re c wnM as cam wm ne u2.rn w' �• i`� %o.+rxa- eD[asss F.n r�ewnrz:msxx .un scxora. reewwn!nav r y � i � r l 1 rx nr£ ✓rutrr cawxv[Es. k �' r ne 4r °a \: .. i I i s ctwavea ✓rrurr rxfrxw .:w ec smxa srr ro u+rcrr xaw .¢�c[w_-Nr �• �• '� 1 / G � % � t ,x+r,) e.Ex..«r=.sm" rrz� a� r�or � � w.rfxcvs. ° cawxmr w5 t[urxw spe szEe+r�• A+r R�+g rsw,xs. �,., f f� + r f cavravrae n Resw.stae sw me assaunmzv /aur rror wFnru£J os j 1, u. a£rnmD .L•cmru[. ewus scwr a.rav L� .war s*w+sstE fzw KOf3'rMJ �'L M6:A[[AIKIVC �\��fx ,$wFR .1 �1/ � � i a. UMW CON1Id1ClDH EAGMN,G UTA.. IRt]tar AMS MS%Nl PoC GAWrY \� \ JB?Y CtlNHrNY NYL QNYN,t' N sISKCI1tYf J' a4j YCAk J ' -} = _ / ��\ ` \ /. j j (! j �l �`ixirrrn wvn�-as. r'�"'im>"£s`• moi' xw �i�vNr s -- - r� 1' �ewr£wvs ,4m erei. R+nr scxEauieL[Lxrn srianrnre+crae ' �, -, \ % urarrr outs n n,[ . onrxn cewaar. /r ! i P 1/�ttt �~ -- r L a. £oa crrxuear a c,.s tewrs aw sER[xrs: cwmuervx rs sum rr t+[s Mws°s"s"rr`r c0p1rra�.abex � � .� �� �a�rzus�sae a� exvrre�.vEau«Ea aswn�°''sizs srm � xmre wna"�i`cr srece u�ra- tt�rv- .uf ! r fwa�m o cx. a!re» ro wmuurc sec,.rvnui-rron ra mru xE t suv attMtn �' ! / Yy0!A swcx;,w£s IN! �07 f LMS AEViI tlln,+relr,a� �\, LMf, r<r p, UIKYfD ro MYSSE � , ' ,';:.. { 4 A1lGTMW ARA Rl1 Ab fill(/ gICMAO - (°° Y —A4— /` ) •.. \, " SCHMUESER GORDON MEYER llra arG,H �,_" ,� D.S e w en s.eee . 5— zoo JU S v (970) oo0 -1 « 4t. eo.oA.,r,o e r eo i A—., 45-1004 70102"727594e PITKIN COUNTY, CO Record Drawing S SCMMUESER� OORDON � MEIER AS'ee, C0.onNon L9]O� 925C]2] r( 6urrrweoe. CO 19]01 641.5355 •*alrr a+. lu Ia��.Lom mr,al aa.I laagr tl++ k.N w.> Pd�rnb1 1I IJSMr] 1.492= IICY Wir IFtI19 a 1014 Omer AadI tc ♦ M Gwl aMM arw.I.rr . PIrI•I lr.l Ia•r tAa-1D-EPS-M'-d1 a• ower a 1. lea rr iwa w o r1•N mrrrn L.n I•r w I,a Ia ma. 3.0 (o3/0e) nsrArLEN mwL. ctawuav ro Au Rraw cnuwr rrtALav LOMNIIa]DI amaAnaa Au ceaanaFaNS a nr tlmrr rumwmr sYsresr (cwrsJ srwu r2r Ananrae AEaAArnws r. rM oars srwL. —1— av AttY w r amr Am —aoet .ono roMSAcrtAleNs AlCkllaQplaOK srasrmmgv5 s rv.Panflws av Mnrzaw.s au ,ver ec Auwm A arrrnwr IhC ATIOMIL LJ< nnF n[xnav EIM^INRIn IrswLw Alai rmalaC arxz nvr aMX Ara.esarvc suNSNwNws. raK LM rai0 AaC .WN.SO 6C naOrtC2D rlrov cbMa(.TpL KMCN.M ALLiF 9RR10 L XPr dF M P•Mr /tlA aLM rALnrs Aw rrEnrr rota IE>.ercr vAx<a nnr a.acoaEn er1 rM aeweta Au sen Rrrrm aN ccMPAnm srwe ae Ncaolm Ann AERALEa amY saw I. Arc PIc nr txMMenoNS srwt er sarexr antro, Larrss oncaarsE sRLn=rn J. AIL ArseN� IwM" eorq Aw rwYn vara vMu vrnlo r Kai ANI£ s nlnvaac rreJxn caelLc san yrcL ar Lvar w AAnUMJ anst,r Aw Aam AAar Fanlr Ar5'W Ar A � ,.r.. ALPn AaPE ro alnAavr a SfalT PPE Aw [aFLLN)'II PPE S'11fL BE PNLMEALr aPDOED PEa IAr r.PEMYr lA!TAn PNOpKa r LAnosrwnnn slvc eE nr AESN.wswem a of aMN. s szns aulr Assnrwv save eE cLMarArenn aArtw rnrr ro ASA.Mr An cwdnv aN nma• Ivrea •at Footer oeJA>r IOLUNs a � A$wYQ 9. PMJngF ALCWMIE AVII-ROIAaLW aENCrT AS MEDL'aED PV SfMM rMK/lYlnlrDlM. ra Y ascarons LK rear PrAw wAr ro Aw ro a ersu.Irm AaaaUw^ ro LCaI! PAowx srteear Arttawae cvlrAacE tweaLro LTrtLEIYr R.VPrna smrar nnPwc sasrtn srwc rwlr A axo aeor,nar 06LawR£ AsseAar. ear Nae x tma aunrtx aRHxcr AT501Mrr sMLL clew eax Iva smrc TAnN. z acalnAce AssElar srrnL MIr A aaenw.eer uMav AacsDerr races aarm rrra roe PUP AnuL:ArNr J R•P s>srd save KLLAr nave RLxr stern's Aa 'W rtdr, AN 2sr Rar Aw A rlesr aoneP ALw. AN Aad/aJNV. Lar aAru Aualr/aEnr,aawr err rtar a nrnavat. A RCxr aPEE nNnp'L Ann rYIEN /IUCne AI1rc friipll'r ro A AMX. LkTM OF rS KMS H2alI ar ra^ Lr IM )AMI' atRA. J N$nIItL)r SIMIt rLnlnrSN Aw MnWl AN IXIeeIYrL .iPr2£ aW: a SR2£ an+r (MUI I) mra.t LE LC AMaaKN ap aFT LCGnpVS r. AfL IIIIF SILKS Saw' IIF COYRlMI MIM K (42a aA2AAaCEr CLMI{CIptS RMwaR PAKt: r. +rsrxtrn save levies AN oatnvro ne olxaro. z toxnelcleN saws awA.tr oaneN ANo/w LLhaw. cnvrMcroN res Loclaow m covnlar ranrt. LLMrneAnrL Awe er AaYAVIED LW IAF El'IE.TnY1 LY' rlYe rLYLLWC MIIh1N .4na/r ro" )M NE3AfiIl1£ PLMMW' Sa31ETl. arD1r Ci AnI A SIAJN[L LLYJ1Ikw M BUAMT rnr NSaL[G 9Nf[ CaVIACI nA+ anxry EAC.amr FON Lll[IwL£ ro ALlFMW)r MNEL LLGnIAw a calvrlaY. MM't sruc x Apowrta Ar A caMtacar Mwavr ro Arctw ALL'S$ Aro aLAArFraner. I. rM Auet swL or Lourzo A.naY nwr nc ALasv cw eF IlrAntr stow Aw NrAm. Top View I------f_TIM-------I !� (Big OHolelear Lid t Ri:;eT Minimum Height Flexibl Panel Boot Sectionr— View I I utyl Rubbe . i I Sealant O I b Tank: Pump: 'Meets ASTM C-1227 spec Lowers TSS and improves effluent Including C-1644-06 for resilient quality to field connectors Easiest pump system to maintain on • 4000 psi concrete the market • Delivered complete with internal piping Complete installation (wiring, panel, Service contracts available /or maintenance mounting and start-up procedures) a Complete warranty Digging Specs invert Dimenalona Effluent Pumping System for Cold Weather Applications (cw style) C9 Inlet 56• ouMt 73• Length 137 Wkllh 68' Height 97 Intel Side 1,002 gaAons Outlet Side 503 galims Total 1.505 gallons rtrrnE ewes rAa r.o' ceaa. SYN SCM A�ar4 Ilal SIFT �..I.I Nm NPS �...I.... aYw�lnLYmxor�l k•t�-MM cwawoo •etpet •*alrr a+. lu Ia��.Lom mr,al aa.I laagr tl++ k.N w.> Pd�rnb1 1I IJSMr] 1.492= IICY Wir IFtI19 a 1014 Omer AadI tc ♦ M Gwl aMM arw.I.rr . PIrI•I lr.l Ia•r tAa-1D-EPS-M'-d1 a• ower a 1. lea rr iwa w o r1•N mrrrn L.n I•r w I,a Ia ma. 3.0 (o3/0e) nsrArLEN mwL. ctawuav ro Au Rraw cnuwr rrtALav LOMNIIa]DI amaAnaa Au ceaanaFaNS a nr tlmrr rumwmr sYsresr (cwrsJ srwu r2r Ananrae AEaAArnws r. rM oars srwL. —1— av AttY w r amr Am —aoet .ono roMSAcrtAleNs AlCkllaQplaOK srasrmmgv5 s rv.Panflws av Mnrzaw.s au ,ver ec Auwm A arrrnwr IhC ATIOMIL LJ< nnF n[xnav EIM^INRIn IrswLw Alai rmalaC arxz nvr aMX Ara.esarvc suNSNwNws. raK LM rai0 AaC .WN.SO 6C naOrtC2D rlrov cbMa(.TpL KMCN.M ALLiF 9RR10 L XPr dF M P•Mr /tlA aLM rALnrs Aw rrEnrr rota IE>.ercr vAx<a nnr a.acoaEn er1 rM aeweta Au sen Rrrrm aN ccMPAnm srwe ae Ncaolm Ann AERALEa amY saw I. Arc PIc nr txMMenoNS srwt er sarexr antro, Larrss oncaarsE sRLn=rn J. AIL ArseN� IwM" eorq Aw rwYn vara vMu vrnlo r Kai ANI£ s nlnvaac rreJxn caelLc san yrcL ar Lvar w AAnUMJ anst,r Aw Aam AAar Fanlr Ar5'W Ar A � ,.r.. ALPn AaPE ro alnAavr a SfalT PPE Aw [aFLLN)'II PPE S'11fL BE PNLMEALr aPDOED PEa IAr r.PEMYr lA!TAn PNOpKa r LAnosrwnnn slvc eE nr AESN.wswem a of aMN. s szns aulr Assnrwv save eE cLMarArenn aArtw rnrr ro ASA.Mr An cwdnv aN nma• Ivrea •at Footer oeJA>r IOLUNs a � A$wYQ 9. PMJngF ALCWMIE AVII-ROIAaLW aENCrT AS MEDL'aED PV SfMM rMK/lYlnlrDlM. ra Y ascarons LK rear PrAw wAr ro Aw ro a ersu.Irm AaaaUw^ ro LCaI! PAowx srteear Arttawae cvlrAacE tweaLro LTrtLEIYr R.VPrna smrar nnPwc sasrtn srwc rwlr A axo aeor,nar 06LawR£ AsseAar. ear Nae x tma aunrtx aRHxcr AT501Mrr sMLL clew eax Iva smrc TAnN. z acalnAce AssElar srrnL MIr A aaenw.eer uMav AacsDerr races aarm rrra roe PUP AnuL:ArNr J R•P s>srd save KLLAr nave RLxr stern's Aa 'W rtdr, AN 2sr Rar Aw A rlesr aoneP ALw. AN Aad/aJNV. Lar aAru Aualr/aEnr,aawr err rtar a nrnavat. A RCxr aPEE nNnp'L Ann rYIEN /IUCne AI1rc friipll'r ro A AMX. LkTM OF rS KMS H2alI ar ra^ Lr IM )AMI' atRA. J N$nIItL)r SIMIt rLnlnrSN Aw MnWl AN IXIeeIYrL .iPr2£ aW: a SR2£ an+r (MUI I) mra.t LE LC AMaaKN ap aFT LCGnpVS r. AfL IIIIF SILKS Saw' IIF COYRlMI MIM K (42a aA2AAaCEr CLMI{CIptS RMwaR PAKt: r. +rsrxtrn save levies AN oatnvro ne olxaro. z toxnelcleN saws awA.tr oaneN ANo/w LLhaw. cnvrMcroN res Loclaow m covnlar ranrt. LLMrneAnrL Awe er AaYAVIED LW IAF El'IE.TnY1 LY' rlYe rLYLLWC MIIh1N .4na/r ro" )M NE3AfiIl1£ PLMMW' Sa31ETl. arD1r Ci AnI A SIAJN[L LLYJ1Ikw M BUAMT rnr NSaL[G 9Nf[ CaVIACI nA+ anxry EAC.amr FON Lll[IwL£ ro ALlFMW)r MNEL LLGnIAw a calvrlaY. MM't sruc x Apowrta Ar A caMtacar Mwavr ro Arctw ALL'S$ Aro aLAArFraner. I. rM Auet swL or Lourzo A.naY nwr nc ALasv cw eF IlrAntr stow Aw NrAm. Top View I------f_TIM-------I !� (Big OHolelear Lid t Ri:;eT Minimum Height Flexibl Panel Boot Sectionr— View I I utyl Rubbe . i I Sealant O I b Tank: Pump: 'Meets ASTM C-1227 spec Lowers TSS and improves effluent Including C-1644-06 for resilient quality to field connectors Easiest pump system to maintain on • 4000 psi concrete the market • Delivered complete with internal piping Complete installation (wiring, panel, Service contracts available /or maintenance mounting and start-up procedures) a Complete warranty Digging Specs invert Dimenalona Net Capacity ',,' Long . B' Wide 56" below inlet in -1 Inlet 56• ouMt 73• Length 137 Wkllh 68' Height 97 Intel Side 1,002 gaAons Outlet Side 503 galims Total 1.505 gallons Net weight LIE Tank Total 3,600 lbs 11,1801bs 14,9801Ds �� LEtet L� CAG111J S" PYC AN rPr ALxPr fSL IIIIFRML� � r0" NOAE Mw „xo r. r"aML Mn 1E s • � r• Iaa YaaL r• DYE Lam - _ � Da � senn rtrrnE ewes rAa r.o' ceaa. SYN SCM FLUSH/NG ASSEMBLY MAIIID A.rIT Mien AaGS ICN E.YIS� AC PN/I. �r rmeLlss. rnt 'Ucaw enrsrmc �Ae ew�.I.sNr. calrlereo sor ro DJr ww aLacaNr a.vrr rro+ exsrAc sve-eag •a~ALVf r< os*w AEalnr•FNrs Aw-✓ilvsr saseYnrse BueED HPE amemc Mlfaw RaPACr �DJr uLY LM1' aM' sora' a• Au sas rrr ,. PrA¢ � LTYACT aracwa M21sIL ee.arE MTNII1a' Po£ 2 rPE ' nIUJI 6[ a/ BALL C9MMCIEa AnD IPr Ma(LED AI rAC Cr LUnC I6 CYIAapY L65[P1' 1NW PIPE DETAIL RLC A1C N (AwSOWnC, eman Ir MIm APEAs on ca�nlErE sLses Ir P+c LS6aa IY P,PE Ir \J� IY APE PIL' err ar ��w' Q°01Y aoa CLEAN—OUT DETAIL (CO) ..1S eIu ru calEn salt rr' arN —nmo }1"'veru rtrrnE ewes rAa r.o' ceaa. oeMrL ar srcar Awt Mss A scaAno x as' MSna REaM1ID Clw A J/I' SIXEEIV 1w nae r I%'PM Rrtmwr umrc RELEF r[K MIrOIM}C aS1e91nM4• Y4YE SSEMBLY .SIM ro YFE/ LNIMIIna SPECS Ar CMILa WT BY CaWIE A,r�x, -a' 41aI1E1 aaR PIE ° .. �� AFa CFN 7 lav _ � 5� ORENCO AUTOMATIC DIS7RIBURNG SALVE + (ADV) MODEL 6605 MOUND SECTION t'N �` � _ o U O Z z N 0 Y z Y F— a DRAWING: SECOND FL. REf. PIAN ISSUE: DATE: PRICING 10.1&11 RENSIONS PERMIT SHEET NO. SECOND FLOOR REFERENCE PLAN A2.2 1 3/32. _ V -0 - NORTH OWYMW CH ES C"HE RUTUTS • 2 U z N V FIRST FL REF. PLAN ISSUE: DATE: PRICING ,N18111 CD PPoCING 02-0fi-11 cD PwclNc os.oa-1s O 0 0 O v Z O U Z Y F- a SHEET N0. A2.1 QWPYMGK IIIARLES E•NNE AR[NIEETS l y939��. Hay Field / Grazing Property Line 4 Property Line Activity Envelope ... Proposed Pond i a1 o Property Line Vehicle Access \ \ Maintained Grass Pathway Through Meadow Hay Field \ Hay Field / Grazing 1� Permit Set K2 Ranch Barn Site Plan [] Scnematic Design Design Development Construction Documents Date: MGM Scale: 1"=sv Drawn By: its Revised: n3n611z 06104/12 11/23M 0 /1e/� 13 00 a'13 OND6113 OY2]/13 04/03/13 04/26113 Sheet: L-1.3 / F Owl Creek Road Property Line I I Activity Envelope Landscaping / Grading And Utility Envelope I"t 79 7% Slope Up Hill \ yI I Gerator Pad 4' Berm ` —` Property Line Landscaping / Grading And Utility Envelope r � I Vehicle Access Maintained Grass Pathway Through Meadow l y939��. Hay Field / Grazing Property Line 4 Property Line Activity Envelope ... Proposed Pond i a1 o Property Line Vehicle Access \ \ Maintained Grass Pathway Through Meadow Hay Field \ Hay Field / Grazing 1� Permit Set K2 Ranch Barn Site Plan [] Scnematic Design Design Development Construction Documents Date: MGM Scale: 1"=sv Drawn By: its Revised: n3n611z 06104/12 11/23M 0 /1e/� 13 00 a'13 OND6113 OY2]/13 04/03/13 04/26113 Sheet: L-1.3 Stone Cap Quartzite Veneer To Match Hou: Boulders Mixed Into Veneer — Reinforced Concrete Structure — Possible Lighting PVC Liner Under Stream Sand Or Soft Base Water Level — Finish Grade Turn Back Liner In Earth Trench Alt. Stone Edge On 6" Aggregate Base To Protect Liner 4"-6" Stone At Wave Action Zone =nm -1111= °o o ° ��° � --- — — -- III= 36 mil Polypropylene Pond Liner, Lap Joints Sealed =1111' ° cp 8. g4/ ° pQ10'.. g o �o� IIII' In The Field, Sand Cushion If Required 111111=1. o--_— �o �'9 JII� � q 1—IIII' Pond Contractor To Confirm 11=IIII=IIII=II=1111 IIII=1111 IIII-1111-1111=1111-IIII=IIII=1111-1111-1111-111 M 1111=1111=1111=110=1111=1111=IIII,= Smooth Prepared Sub -grade Free Of SharpStones -IIII=IIII=1111 IIII=IIII=IIII=IIII=IIII=IIII=IIII=IIII=IIII=IIII=IIII=IIR=IIII IIII=IIII=IIII=IIII=IIII=IIII=Ioi— Or Specify PVC Liner 6-7 4" Fine Aggregate Bottom ter Wall Section �.leltream Section 1/2"=1'-0" L" ProposedWetland Sod Subgrade Elevation: -.8' Key Trench Perimeter Proposed Pond Water Surface Elevation: 0' �Varies Liner Key Trench Elevation: +5 Pond Contractor To Confirm Or Specify PVC Liner TyrAcal P� Scale - 1/4"=1'-0" Salvaged Fill Eight Ounce/ sq. Yard Nonwoven Geotextile (Propex Geotex 801 Or Equivalent) 36 -mil Reinforced Polypropylene Liner Salvaged / Imported Topsoil Compacted Subgrade 0 '0015 Co... Wall With Ston. vs and Stone Cop 5• Thick Reinforced Concrete G.neroior 6.11" n 3'5.25" +TW 25.80' Scale - 1/4"=1 Construction Final Pricing Set K2 Ranch Details ❑ Schematic Design Design Development ■ can.truction Documents Date: 02IM12 Scale: _ As Shown Drawn By: 4/M Revised: 0&1&12 0&04/12 11/23112 92!19/13 o—a(13 MUM Sheet: L-5.5 7905 S£RV10E 70 HOUSE, PENS EXTENSION FROM ROPERTY CORNER," ERWCL P ON MECFWNTCA PLANS - OIL CAS GENERATOR LOCAAON. 0 A!£P PLANS FOR GENERATOR 4710NS REFER TO LANDSCAPE OR DETAILED GRADING REQUIRE, -7922- U 4q..••TO BE K2 RANCH PITKIN C'O UNTY. CO 1gg# ,'•- RENSh7N PERMIT SET CONSTRUCTION/F/NAL PRICING SET 5 1 BERM GRADING REWSION 1921 WELL WATER WILL REQUIRE TREATMENT PR/OR TO USE. _ FINAL TREATMENT UNIT SPECF7C4T/ON TO BE DETERMINED AFTER FURTHER WATER QUALITY T£S77NC. AT A MINIMUM, WAj£R SOfTENNNG WILL BE REQUIRED. 5,000 -CAL WATER STORAGE 7ANK FOR DOMESAC AND INTERNAL f7RE SUPPRESS/ON US£ 'S�6! 4" PVC OVERFLOW (S££ DETAIL, SHEET C6). PUMP SPEC P£NT>I" •.. PIPE 70 LY1YLlGHT DETERM/NA770N OF DOMESTIC ANO f7RE a •.: ��-""""^..� .. �'\ �01JJE�ElO9fA59. ]6 U "..,, 'N'l6d.T2p,l9• E l090Q211 p � WIN GENERAL UTILITY NOTES - I. ALL LOCATIONS FOR EXIS77MG UTILITIES SHOWN ON PLAN ARE APPROXIMATE PRIOR TO ANY SITE EXC4VATION, CONTACT THE U77UTY NOTIFICA710N CENTER OF COLORADO (UNCC) AT I -800-922-1987. 2 SHALLOW UTIL177ES SHOWN ON THE PLANS ARE SCHEA077C IN NATURE FINAL UTILITY OUANTMES TO BE BASED ON FIELD REQUIREMENTS J. ELECTRIC, GAS, AND TELEPHONE U77LITY INSTALLATIONS TO BE MADE IN S71?ICT ACCORDANCE MIN UTILITY COMPANY REOUIREMENTS WITH RESPECT TO BEDDING, TRENCH DETAIL, DEPTH OF BURY, MATERNLS, ETC (SEE TYPICAL DETAIL SHEET C6). WHERE CONFLICTS BETWEEN UAL/TY COMPANY REQUIREMENTS AND THESE DRAWINGS OCCUR, U77LITY COMPANY REOUIREM£NIS SHALL GOVERN. 4. JOINT UTILITY 7RENCH WORK MAY NOT ACCOMMODATE THE RESPECTNE U77UTY REQUIREMENTS U77LITY COMPANIES MAY REQUIRE CHANCES TO THESE PLANS ONCE IN THE FIELD. THE CONTRACTOR MUST COMPLY WITH THE U77LITY COMPANY REOUES75 AND AN77CIPATE LOCIS77C4L AND SCHEDULE COORDINAAON WITH THE UTILITY COMPANIES. 5. COMBINED UTILITY TRENCH CAN BE FELL) FIT TO MATCH ROAD ALIGNMENT AND AVOID CONFLICTS W/7H D241NAGE ELEMENTS PROVIDE HAND HOLES (AIN. 3X4XJ) EVERY 400'-500' FEET OF TRENCH. 6. CONTRACTOR IS RESPONSIBLE FOR ALL UALI7Y TRENCHWORK, BEDDING MATERIALS & CONDUIT IIVSTALLA77ON FOR ELECTRIC AND PHONE UALIAES CONTRACTOR IS RESPONSIBLE FOR THE INSTALLA770N (BUT NOT PURCHASE) OF ALL REQUIRED EZEC7RM.4L VAULTS. CONTRACTOR IS NOT RESPONSIBLE FOR \ PEDESTAL/RISER INSTALLATIONS 'Ry 7. UPON CONTRACTOR £XC4VAT/NG UTILITY TRENCH AND INSTALLING CONDUIT, UTILITY COMPANY WILL CONDUCT AN INSPECAON OF THE WORK PRIOR TO B4CKFILL OF TRENCH AND WILL MEASURE AMOUNT OF UTILITY LINE NEEDED. U7TUTY COMPANY WILL WRITE A CONTRACT WITH PROPERTY OWNER FOR AME & MATERIALS AND WILL THEN SCHEDULE U77LITY SUBCONTRACTOR 70 INSTALL '.. U77LITY LINES IN THE FRONDED CONDUIT. 1921 B. FOR INSTALLATION OF GAS MAINS AND SERWCES CONTRACTOR IS RESPONSIBLE FOR ALL TRENCHWORK AND BEDDING MATERIAL. SOURCEGAS WILL INSPECT TRENCH, DET£RM/NE REQUIRED QUANAAES AND WILL WRITE A CONTRACT WITH PROPERTY OWNER, PRIOR TO SCHEDULING SUBCONTRAC70R TO INSTALL ALL GAS PIPELINES. 9. APPROVED SHORING PROVIDED BY C0NTRACT0R/DEl2ZOP£R FOR WHEN UTILITY COMPANY EMPLOYEES NEED 70 ENTER AN EXCAVAAON AREA 5 FEET OR MORE IN DEPTH. tI 1\ —L.sum - L1AlE BY Job No. 2011-371.007 �� �JnD, NEK UTILITY PLAN Drown by.- m, 1J JJ NEK D°M: 10109112011 T l3 NEK 51ZIIJ NEK OC. PE JH OF �.EGEND EXISTING OVERHEAD ELECTRIC NG- NEW GAS LINE NE NEW ELECTRIC LINE �C,TNEW TELEPHONE/CABLE 7V ZINE Nl*. NEW J" WATER LINE \ !'a'AA NEW 2" WATER LINE ORENCO ADV 6.605, --ills NEW 4" SLWER LINE \ AUTOMATIC OLS7RlBUTING f/• \ 37,/.," s VALVE (SEE.3'H£ET 477)' LING \ \ ro \ .......... OWTS OUND, ........ \ SEE EI'ILS \ \6ft \ 1g \\ SHE C7 :' f \� / E $ 4 fa"•'U \ 1 \ A\ 7905 S£RV10E 70 HOUSE, PENS EXTENSION FROM ROPERTY CORNER," ERWCL P ON MECFWNTCA PLANS - OIL CAS GENERATOR LOCAAON. 0 A!£P PLANS FOR GENERATOR 4710NS REFER TO LANDSCAPE OR DETAILED GRADING REQUIRE, -7922- U 4q..••TO BE K2 RANCH PITKIN C'O UNTY. CO 1gg# ,'•- RENSh7N PERMIT SET CONSTRUCTION/F/NAL PRICING SET 5 1 BERM GRADING REWSION 1921 WELL WATER WILL REQUIRE TREATMENT PR/OR TO USE. _ FINAL TREATMENT UNIT SPECF7C4T/ON TO BE DETERMINED AFTER FURTHER WATER QUALITY T£S77NC. AT A MINIMUM, WAj£R SOfTENNNG WILL BE REQUIRED. 5,000 -CAL WATER STORAGE 7ANK FOR DOMESAC AND INTERNAL f7RE SUPPRESS/ON US£ 'S�6! 4" PVC OVERFLOW (S££ DETAIL, SHEET C6). PUMP SPEC P£NT>I" •.. PIPE 70 LY1YLlGHT DETERM/NA770N OF DOMESTIC ANO f7RE a •.: ��-""""^..� .. �'\ �01JJE�ElO9fA59. ]6 U "..,, 'N'l6d.T2p,l9• E l090Q211 p � WIN GENERAL UTILITY NOTES - I. ALL LOCATIONS FOR EXIS77MG UTILITIES SHOWN ON PLAN ARE APPROXIMATE PRIOR TO ANY SITE EXC4VATION, CONTACT THE U77UTY NOTIFICA710N CENTER OF COLORADO (UNCC) AT I -800-922-1987. 2 SHALLOW UTIL177ES SHOWN ON THE PLANS ARE SCHEA077C IN NATURE FINAL UTILITY OUANTMES TO BE BASED ON FIELD REQUIREMENTS J. ELECTRIC, GAS, AND TELEPHONE U77LITY INSTALLATIONS TO BE MADE IN S71?ICT ACCORDANCE MIN UTILITY COMPANY REOUIREMENTS WITH RESPECT TO BEDDING, TRENCH DETAIL, DEPTH OF BURY, MATERNLS, ETC (SEE TYPICAL DETAIL SHEET C6). WHERE CONFLICTS BETWEEN UAL/TY COMPANY REQUIREMENTS AND THESE DRAWINGS OCCUR, U77LITY COMPANY REOUIREM£NIS SHALL GOVERN. 4. JOINT UTILITY 7RENCH WORK MAY NOT ACCOMMODATE THE RESPECTNE U77UTY REQUIREMENTS U77LITY COMPANIES MAY REQUIRE CHANCES TO THESE PLANS ONCE IN THE FIELD. THE CONTRACTOR MUST COMPLY WITH THE U77LITY COMPANY REOUES75 AND AN77CIPATE LOCIS77C4L AND SCHEDULE COORDINAAON WITH THE UTILITY COMPANIES. 5. COMBINED UTILITY TRENCH CAN BE FELL) FIT TO MATCH ROAD ALIGNMENT AND AVOID CONFLICTS W/7H D241NAGE ELEMENTS PROVIDE HAND HOLES (AIN. 3X4XJ) EVERY 400'-500' FEET OF TRENCH. 6. CONTRACTOR IS RESPONSIBLE FOR ALL UALI7Y TRENCHWORK, BEDDING MATERIALS & CONDUIT IIVSTALLA77ON FOR ELECTRIC AND PHONE UALIAES CONTRACTOR IS RESPONSIBLE FOR THE INSTALLA770N (BUT NOT PURCHASE) OF ALL REQUIRED EZEC7RM.4L VAULTS. CONTRACTOR IS NOT RESPONSIBLE FOR \ PEDESTAL/RISER INSTALLATIONS 'Ry 7. UPON CONTRACTOR £XC4VAT/NG UTILITY TRENCH AND INSTALLING CONDUIT, UTILITY COMPANY WILL CONDUCT AN INSPECAON OF THE WORK PRIOR TO B4CKFILL OF TRENCH AND WILL MEASURE AMOUNT OF UTILITY LINE NEEDED. U7TUTY COMPANY WILL WRITE A CONTRACT WITH PROPERTY OWNER FOR AME & MATERIALS AND WILL THEN SCHEDULE U77LITY SUBCONTRACTOR 70 INSTALL '.. U77LITY LINES IN THE FRONDED CONDUIT. 1921 B. FOR INSTALLATION OF GAS MAINS AND SERWCES CONTRACTOR IS RESPONSIBLE FOR ALL TRENCHWORK AND BEDDING MATERIAL. SOURCEGAS WILL INSPECT TRENCH, DET£RM/NE REQUIRED QUANAAES AND WILL WRITE A CONTRACT WITH PROPERTY OWNER, PRIOR TO SCHEDULING SUBCONTRAC70R TO INSTALL ALL GAS PIPELINES. 9. APPROVED SHORING PROVIDED BY C0NTRACT0R/DEl2ZOP£R FOR WHEN UTILITY COMPANY EMPLOYEES NEED 70 ENTER AN EXCAVAAON AREA 5 FEET OR MORE IN DEPTH. tI 1\ —L.sum - L1AlE BY Job No. 2011-371.007 �� �JnD, NEK UTILITY PLAN Drown by.- m, 1J JJ NEK D°M: 10109112011 T l3 NEK 51ZIIJ NEK OC. PE JH OF AND 7EZ£PHON£ S£ 7RENCH,:'DEMIL \ \ 1g \ .I. \ . \\ \� \ ++ ORENCO ADV 6.605, \\ f•,^„^. \ AUTOMATIC OLS7RlBUTING f/• \ 37,/.," s VALVE (SEE.3'H£ET 477)' LING \ \ ro \ .......... OWTS OUND, ........ \ SEE EI'ILS \ \6ft \ 1g \\ SHE C7 :' f \� 4 \ 1 \ 1 1 ! ntt1 1 \ of 1,5 L, TWO-COMPARTMENT•. \ SE AC TANK WNH EF/Z / (SEE DETAIL C7) T .. ,: , \\ \ /:' / :•' 1919 \ /1 \ \ \ \ .l.... OWTS DESIGN CALCULAAONS.• \\ \\ 1. 9 BEDROOM RESIDENCE 2 PEOPLE PER BEDROOM, 100 GALLONS - "•'•.•...\...•••. \\ ...................... 'N POLE AND \ � PER PERSON PER DAY;P07EN774L 84RN ADD?ION AT 45 GPD. GUY 2. AVERAGE DAILY FLOW = 1845 CPD E \ \ /NE J. DES/GN FLOW = 1845 GPD X 1.5 = 27675 CPO \ \ NE x ' 4. ABSORPAON AREA FOR SAND FILTER MOUND = (OD X FYF)/LTAR Eryof ................. 8184............ ...... ..:.. ........ (2767.5 X 1.0)/0.95 = 2973 SF •i5' DOSING REDUCAON (-20R) - 2331 SF ' \ FIELD: 58' X 41' = 2378 SF \ SCHMUESER GORDON MEYER �V 1 1 8 W. 6TH STREET, SUITE 200 GLENWOOD SPRINGS, COLORADO 8 1601 (970) 945-1004 FAX (970) 945-5948 SCHMUESER I GORDON I MEYER ASPEN, COLORADO (970) 925-6727 ENGINEERS 1 SURVEYORS GUNNISON, CO (970) 641-5355 7905 S£RV10E 70 HOUSE, PENS EXTENSION FROM ROPERTY CORNER," ERWCL P ON MECFWNTCA PLANS - OIL CAS GENERATOR LOCAAON. 0 A!£P PLANS FOR GENERATOR 4710NS REFER TO LANDSCAPE OR DETAILED GRADING REQUIRE, -7922- U 4q..••TO BE K2 RANCH PITKIN C'O UNTY. CO 1gg# ,'•- RENSh7N PERMIT SET CONSTRUCTION/F/NAL PRICING SET 5 1 BERM GRADING REWSION 1921 WELL WATER WILL REQUIRE TREATMENT PR/OR TO USE. _ FINAL TREATMENT UNIT SPECF7C4T/ON TO BE DETERMINED AFTER FURTHER WATER QUALITY T£S77NC. AT A MINIMUM, WAj£R SOfTENNNG WILL BE REQUIRED. 5,000 -CAL WATER STORAGE 7ANK FOR DOMESAC AND INTERNAL f7RE SUPPRESS/ON US£ 'S�6! 4" PVC OVERFLOW (S££ DETAIL, SHEET C6). PUMP SPEC P£NT>I" •.. PIPE 70 LY1YLlGHT DETERM/NA770N OF DOMESTIC ANO f7RE a •.: ��-""""^..� .. �'\ �01JJE�ElO9fA59. ]6 U "..,, 'N'l6d.T2p,l9• E l090Q211 p � WIN GENERAL UTILITY NOTES - I. ALL LOCATIONS FOR EXIS77MG UTILITIES SHOWN ON PLAN ARE APPROXIMATE PRIOR TO ANY SITE EXC4VATION, CONTACT THE U77UTY NOTIFICA710N CENTER OF COLORADO (UNCC) AT I -800-922-1987. 2 SHALLOW UTIL177ES SHOWN ON THE PLANS ARE SCHEA077C IN NATURE FINAL UTILITY OUANTMES TO BE BASED ON FIELD REQUIREMENTS J. ELECTRIC, GAS, AND TELEPHONE U77LITY INSTALLATIONS TO BE MADE IN S71?ICT ACCORDANCE MIN UTILITY COMPANY REOUIREMENTS WITH RESPECT TO BEDDING, TRENCH DETAIL, DEPTH OF BURY, MATERNLS, ETC (SEE TYPICAL DETAIL SHEET C6). WHERE CONFLICTS BETWEEN UAL/TY COMPANY REQUIREMENTS AND THESE DRAWINGS OCCUR, U77LITY COMPANY REOUIREM£NIS SHALL GOVERN. 4. JOINT UTILITY 7RENCH WORK MAY NOT ACCOMMODATE THE RESPECTNE U77UTY REQUIREMENTS U77LITY COMPANIES MAY REQUIRE CHANCES TO THESE PLANS ONCE IN THE FIELD. THE CONTRACTOR MUST COMPLY WITH THE U77LITY COMPANY REOUES75 AND AN77CIPATE LOCIS77C4L AND SCHEDULE COORDINAAON WITH THE UTILITY COMPANIES. 5. COMBINED UTILITY TRENCH CAN BE FELL) FIT TO MATCH ROAD ALIGNMENT AND AVOID CONFLICTS W/7H D241NAGE ELEMENTS PROVIDE HAND HOLES (AIN. 3X4XJ) EVERY 400'-500' FEET OF TRENCH. 6. CONTRACTOR IS RESPONSIBLE FOR ALL UALI7Y TRENCHWORK, BEDDING MATERIALS & CONDUIT IIVSTALLA77ON FOR ELECTRIC AND PHONE UALIAES CONTRACTOR IS RESPONSIBLE FOR THE INSTALLA770N (BUT NOT PURCHASE) OF ALL REQUIRED EZEC7RM.4L VAULTS. CONTRACTOR IS NOT RESPONSIBLE FOR \ PEDESTAL/RISER INSTALLATIONS 'Ry 7. UPON CONTRACTOR £XC4VAT/NG UTILITY TRENCH AND INSTALLING CONDUIT, UTILITY COMPANY WILL CONDUCT AN INSPECAON OF THE WORK PRIOR TO B4CKFILL OF TRENCH AND WILL MEASURE AMOUNT OF UTILITY LINE NEEDED. U7TUTY COMPANY WILL WRITE A CONTRACT WITH PROPERTY OWNER FOR AME & MATERIALS AND WILL THEN SCHEDULE U77LITY SUBCONTRACTOR 70 INSTALL '.. U77LITY LINES IN THE FRONDED CONDUIT. 1921 B. FOR INSTALLATION OF GAS MAINS AND SERWCES CONTRACTOR IS RESPONSIBLE FOR ALL TRENCHWORK AND BEDDING MATERIAL. SOURCEGAS WILL INSPECT TRENCH, DET£RM/NE REQUIRED QUANAAES AND WILL WRITE A CONTRACT WITH PROPERTY OWNER, PRIOR TO SCHEDULING SUBCONTRAC70R TO INSTALL ALL GAS PIPELINES. 9. APPROVED SHORING PROVIDED BY C0NTRACT0R/DEl2ZOP£R FOR WHEN UTILITY COMPANY EMPLOYEES NEED 70 ENTER AN EXCAVAAON AREA 5 FEET OR MORE IN DEPTH. tI 1\ —L.sum - L1AlE BY Job No. 2011-371.007 �� �JnD, NEK UTILITY PLAN Drown by.- m, 1J JJ NEK D°M: 10109112011 T l3 NEK 51ZIIJ NEK OC. PE JH OF