HomeMy WebLinkAboutpitkin.eh.264315302002 (2013) (CDU)— Pitkin County Environmental N"th Department Onsite Wastewater Treatment System (OWTS) USE PERMIT Permit for Continued Use of an Existing OWTS 76 Service Center Road, Aspen, CO 81611 Phone: 970-920-5070 Fax: 970-920-5374 L.�.v npitkin.com/EHNR Parcel ID #: I 2643-15J-02-002 Type OWTS Use Permit #: I 0010.2013.powu (2) Date Issued: 03/12/2013 Issued By: Kurt Dahl Expiration Date: 03/12/2014 Owner(s): I Jennifer Craig Property Address: 1814 Woody Creek Rd (Caretaker Dwelling Unit) Legal Description: Parcel 4 Craig Ranch Parcels Licensed Inspector: Carla Ostberg Inspection Date(s): 02/12/2013 SYSTEM INFORMATION Compone is Type Capacity/Size Primary Treatment Unit concrete Two-compartment tank 1000 gallon Secondary Treatment Unit Concrete "de-nitrifing" tank 500 gallons Absorption Area Gravelless chambers 9 chambers (279 ft2) Other System Co ponents Dosing chamber with syphon OWTS Use Status: ® In use at thE time of the inspection ❑Not in use at the time of the inspection.* *If the OWTS was not in use cit the time of the inspection, it is recommended that the system be re-evaluated when it is in use for a more accurate evaluation of the system. System Records: Permit #: 98053 Date of Issuance: Date of Final Approval: 11/06/1998 # of Bedrooms or fixturjes served by OWTS: 2 Operational Status: The inspector noted the system appears to be functioning properly. The 1000 gallon septic tank is in good condition and water tight. The 500 gallon "de-nitrifing" tank and dosing syphon and working and there is no evidence of surfacing effluent. Inspector Recommendations: Clean the effluent filter annually, monitor pipe coming into the dosing syphon chamber for additional settling. Department Recommendations: monitor pipe coming into the dosing syphon chamber for additional settling. Issuance of this OWTS Use Permit is based solely on the conditions observed and reported by the inspector to the Department on the date of the inspection(s) and on Department records at the time of permitting. The issuance of this permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail or that the system will not be subject to future enforcement action to correct non-compliant conditions. Estimated capacity of the system has been listed on the permit and we recommend that you monitor and/or meter water use to prevent overuse and possible failure. Owner's Name: '3 0'r) rl t 6!: 'r Crcy (>' Address:- r i 0, 0A \t t - ('( ,, C7 Parcel Number: to -3— I E2 t72- OJ -Z_ Inspection Date: 2 2 Inspector's Name: P - Business Name: f1C Phone Number �G�Zej Email: 2 Pitkin County Systems Inspector License Numbee Q A cavy of this inspection report will be remitted to Pitkin County Enviranmentaf Health Department by the t icenseft Systems Inspector within 60 days of the inspection regardless of whether the system passes or Lails. QUESTIONS FOR PROPERTY OWNER PRIOR TO INSPECTION: Is the home currently occupied? NO If NO, how long has the home been vacant? How many bedrooms are in the home? If secondary treatment is used, who is the t C C maintenance provider? RECORDS: Were system records availablefromPitkin County? YES NO C If YES: Permit number: Date of Final Approval:�� # of bedrooms permitted: c- ,fix Was an as -built drawing available? YES NO l (�`I, Is the as -built drawing accurate? YES NO If NO: Complete a drawing of the system on last page of this form as accurately as possible. Any question marked FAIL will require correction before an OWTS Use permit is issued. SITE CONDITIONS: Proper grading, no evidence of erosion?PASS FAIL Improper vegetative cover? C� YES Evidence of compaction such as heavy machinery or livestock? C. jt YES Improper discharges such as straight pipes? PAS FAIL Evidence of hil;h ground water? NO YES`' Snow cover present? NO YES 0 Page 1 Iii IN Onsite Wastewater Treatment Systems (OWTS) Use a Permit Inspection Form r LI NT Pitkin County Environmental Health Department 76 Service Center Rd, Aspen, CO 81611 Phone: 970-920-5070 Fax: 970-920-5374 Website: www.aspenpitkin.comJehnr Inspection form for continued use of an existing OWTS Owner's Name: '3 0'r) rl t 6!: 'r Crcy (>' Address:- r i 0, 0A \t t - ('( ,, C7 Parcel Number: to -3— I E2 t72- OJ -Z_ Inspection Date: 2 2 Inspector's Name: P - Business Name: f1C Phone Number �G�Zej Email: 2 Pitkin County Systems Inspector License Numbee Q A cavy of this inspection report will be remitted to Pitkin County Enviranmentaf Health Department by the t icenseft Systems Inspector within 60 days of the inspection regardless of whether the system passes or Lails. QUESTIONS FOR PROPERTY OWNER PRIOR TO INSPECTION: Is the home currently occupied? NO If NO, how long has the home been vacant? How many bedrooms are in the home? If secondary treatment is used, who is the t C C maintenance provider? RECORDS: Were system records availablefromPitkin County? YES NO C If YES: Permit number: Date of Final Approval:�� # of bedrooms permitted: c- ,fix Was an as -built drawing available? YES NO l (�`I, Is the as -built drawing accurate? YES NO If NO: Complete a drawing of the system on last page of this form as accurately as possible. Any question marked FAIL will require correction before an OWTS Use permit is issued. SITE CONDITIONS: Proper grading, no evidence of erosion?PASS FAIL Improper vegetative cover? C� YES Evidence of compaction such as heavy machinery or livestock? C. jt YES Improper discharges such as straight pipes? PAS FAIL Evidence of hil;h ground water? NO YES`' Snow cover present? NO YES 0 Page 1 TANK: Tank 1 Is a pump or dosing siphon present? Tank 2 if YES, is the pump/dosing siphon functioning properly? Tank 3 Does the pump/wiring/dosing siphon appear to be in good condition? Tank capacity Is the high water alarm working, both visible and audible? gallons SECONDARY TREATMENT: gallons Is a secondary treatment unit present? YES gallons Tank material,�� NO Does the owner have a current maintenance contract for the unit? YES NO UNKNOWN Maintenance Provider: Phone: If there is no maintenance contract, a contract must be in place prior to occupancy of the home. A #t of compartments Health Department. j Date of last pumping a%�2rf.4711 Lids/risers in good conditionPASS` FAIL PASSV' FAIL f PAS FAIL Risers to grade YES NO `,� NO , YES NO Riser height Riser condition/watertightness r� Inlet sanitary T/baffle FAIL PASS FAIL PASS FAIL Outlet sanitary T/bafflePAS FAIL PASS FAIL PASS FAIL Effluent filter (if part of design) Condition of tank material ASS AIL c -PM N/A FAIL PASS FAIL (PASS N/A FAIL' PASS FAIL AS N/A FAIL Tank was pumped for inspection YES 0 YES NO 'YES NO If YES, list the pumping company 27 2,p I If NO, when was the last pumping Scum level (1st compartment) inches inches inches Sludge level (1st compartment) ('t." inches inches inches Scum level (2nd compartment) " inches inches inches Sludge level (2nd compartment) inches inches inches Backflow (if pumped) PASS FAIL PASS FAIL PASS FAIL Midtank baffle FAIL N/A PASS FAIL N/A PASS FAIL N/A Watertightness FAIL PASS FAIL PASS FAIL PUMPS/DOSING SIPHONS: Is a pump or dosing siphon present? YES NO if YES, is the pump/dosing siphon functioning properly? PASS FAIL - Does the pump/wiring/dosing siphon appear to be in good condition? PASS FAIL Is the high water alarm working, both visible and audible? PASS FAIL i.j [A, SECONDARY TREATMENT: f Is a secondary treatment unit present? YES NO> UNKNOWN If YES, does the unit appear to be in good working condition? YES NO Does the owner have a current maintenance contract for the unit? YES NO UNKNOWN Maintenance Provider: Phone: If there is no maintenance contract, a contract must be in place prior to occupancy of the home. A copy of the contract must be submitted to Pitkin County Environmental Health Department. ABSORBTION AREA: Effluent surfacing? Evidence of past surfacing? Surface dampness? Excessive odors? Field location verified by observation ports or probing: Liquid in observation port? If YES, record depth: Distribution Box or ADV part of original design? If YES, is it accessible from grade? Is it level and in good condition? PASS NO `Ports FAIL YES YES YES Probing YES inches YES NO YES NO PASS FAI L Page 2 UNKNOWN M Any problems with the system that were not addressed in the inspection checklist? Please list any recommendations for the continued use of the Were any repairs done as a result of this inspection? NO YES If YES, please c escribe the repairs. To the best of my knowledge and training, the information collected in this inspection is accurate as of 11�7 , 20 t0. Licensed Sys't�rns Inspector Signature: � Q ( L Additional Notes: Y 7j } r 1 Irl f r .' -1�1 Clearly label any pictures and attach them to this form. Page 3 ��/� -� |\ �/[\�/`/� ( vp\ Ifnoas-built drawings exist for this system orthe as -built was inaccurate, please diagram the system as accurately aspossible. Besure uvdocument all system components and the location ofany well onthe property. Using markers such as corners of the house, exact measurements can be used to triangulate the location cfthe system components for future reference. AI 414 4. / / } \ . > / .t 07 98 02:3 p Doug From�Fivp.rud 6.Fta cy. Fm 76C��T4 Yolv.; iC}463iJT Throm To; ccuy 7MCM {c Deep TV= Cwamcnon 970-925-2465 p.1 Pagel of6 T7 MAM &gte dye engineering 70144 e,,=7&+vetl ay., #2, ,/7)enver, Co. 80231 303-755-4374 vn9legeQeeentral.eom Betsy Kipp, Aspen -Pitkin County Environmental Health 130 S. 4alena Street Aspen, It6lorado 81611 (970)920-5070 August 20, 1998 Ref: Jennifer Craig, Cabin Addition 1814 Woody Creek Road Woody Creek, Colorado proposed ISDS. Dear Ms. k;ipp: 'Phis letter, and attached two drawings, constitute the proposed design of an individual Sewage Diiposal System for the above named property. The County application form and fee, the percolation -profile test report, and a copy of the proposed building floor plan are enclosed as well. Calculatlon of Sewage Flow: Residential floor area: less than 704 square Feet Bedrooms: Sze fo Per Capita flow (table 1) : ons per day t Average flow = 2 bdtm x 2 persons x 75 gpd = 300 gpd )Coo r, ' Design Flow = 300 x 1.75 = 525 gallons per day Size of Septic Tank: per table 8-2, 750 gallons Install: A 1000 gallon 2 -compartment concrete tank, with side envy for the building sewer, improved inlet piping, quieter fluid transfer to the second compartment, and an Oreaco 4" Biotube effluent filter_. The second tank, 500 gallons in size will be a nitrifyin de-nitri ±ng chamber filled with 1'/z inch gravel to provide a meas m orhed gro�itit out n 2rtfyinsio- _ - - m ...tun. -,. ... __ - m _,... x►ilriTjnnactettia. The second tank and the dosing chambar will be vented to lite atmosphere tttrougkt a 6" Orenco activated carbon frlter- The third unit r�itl be a 30" diameter ribbed FVC dosing thaan6er containing an (henco model 336 dosing siphon. As 3 ft of water is drawn out of tank two and the dosi:tg chamber during siphon operation, air is drawm in to support the action of the aerobic nitrifiers; as the volume re -fills, the condition ort the gravel surfaces becomes anoxic, and supports the action of the de-nitrifiers. There will be an Orenco siphon -sitter I to monitor siphon operation. Siphon will discharge 250 gallons per cycle, at a nominal rate of 83 gpm, or 110 gpm max. Distribution: Reduction to a 2" nipple in the splitting manifold will assure an even split between infiltrator rows. This reduction will cause a 5" headloss at the nominal siphon discharge rate. A 4" (originally solid) distribution pipe, the full length of each row, tivill be hung with nylon ties at the crown of the [lot U7 86 U2:36p Doug Throm Rom: Fltsy.,�4 %.St. Gy. V— 6077"-ITTl Y.1-1303-7994374 To: DouyThrem. %t:OoU9Thro COnst.uoCep 970-925-246h P.2 Pag620r6 Fkay Aug"t22, 1M T 24:40 AM infiltrators_ It will have two 5ig" holes hand -drilled at the "10 and 2 O'clock" positions every 6 ft. (one hair of holes per infiltrator, near the center of the unit). These holes will assure even distribution of the dose along the entire row length, by causing a 1.5" headloss at the nominal siphon discharge rniC. A single 3/8" hale drilled on a slant at the "6 O'clock" posiliun, within 2" of each end of each row, will allow complete draining of the pipe, whi le directing their main force against the infiltrator endplates instead of the soil absorbing surface. Ends of distribution pipes to be capped. Size of Absorption Field: Referring to the attached profile investigation and pare test, average perc rate is13.7 MPI. Area = (525/ 5) x 13.7' = 389 fP We are requesting the allowed 30% reduction of area for the use of infiltrators area a 389 x .7 = 272 ft2 At 15,5 W per infiltrator unit: 272'15.5 – 17.6 units Install: 18 units in two rows of 9 each Infiltrators will be placed on a level soil absorbing surface dug parallel to the contours of the slope, at a minimum depth of 3.5 ft below grade at the lower edge. The itiio infiltrator rows will be vented with straight pipes to above grade, placed at the far end. and having rodent -proof screen. This will allow for air displacement during the rapid discharge of the siphon. lviirifi 180-N geotextile (or equivalent) will be draped along the vxo long sides of the excavation, from absorption surface up. Theft backfill will be placed in the normal manner to a level 6" above the crown of the units. Then the fabric will be draped over the fill, and backfilling will continue until original grade is restored. This is being called for at Health department request, to protect against extreme flood scour during a flood event exceeding the 100 year return probability. Please note that the toe of the slope, and in l—_ Disturbed areas on the slope w,11 be rale , �e tth an appro rt� mixture pF�q ve seeds, re - tamped, and protected with excelsior bPl q ppropriatq i 479 Sincerely, F. P. Fitzgerald Colorado Registered Professional Engineer #19656 Bet 07 SH 02�JE;p Doug itirom 370-325-2465 p.3 Frame F"S"O/ipib f7ry s $03-7644st4 vww: 7a3-7654174 Te: O.Uz7— Pap36t6 FH6sy.AuCUt21.1W87�26:43 AM '11V{ wi� r 1 inL'h = J? fi i +f Gvj/dr%7o Sewer Co.,) be .3. tviow fiir5n floor rive% Jennifer Craig 1$14 Woody Creek Rd Woody Creak, Pitkin County Colorado E31656 5£E 'T?Ak5 FCK ,CLL rANKS min:mum spacc. t7duse to icnk, is 5 fey? 1000 q,711un, cor ncr d, 2 -compartment sec,'ic tort*, SnTe entry. 500 yxi/tort cor'n-er'. / Fn7/e compor.mel fork for de-n.i,Zy:nq JO" rZtc!d ;ayst;c pvmlp ChOmbpr \ for ddsia.:f sphor' =� 250 �.agnc A �+ \"sem .s 20 \ 1� O \U i0 dbC�'8 O � � grade, :rilh -c. ; ` rodent -proof Scr2Pn. o � ' t Ott—Site $elvoge Soi: Absorption System SITE PLAN syA{PM Df.gI1 (PROPOSED) Eagle Ey- Engineer la g 10144£. r'eweilRv,'2 Daum; CWvrudb� 80231 SW -72V-4-574 4,°74 Uct U"✓ SH UL -1:36P Doul Throm 970-925-246b p' 4 R&TCMtrald Eapb;vt For 393-7664M Valw3M.765437E TvDauy7hrom atDoagThromCcnaftdon P40046fa FtMIy. tLCi+tt21.!age 72516AN Oc�r Orccl3 Q1 /,7/ PROPdSED bd mdy ne. plccej 6" di„mder eCt%vaed- .-o:-bort Fdfcr fur uoFar confrgl of loa4 vent;n�7. r,7eer q in Mcr, rorher #r .a _ I yrw4, ro pravert heezlag of m Wwe .%tl'in 1hr corbp i gr v/rt. w4'R %onk 1. !;v nffarniotofy dre+vinq ,h lr6sir a;[ Ond re-1Vliog MY" Seplic lent effluent dnbhred over the rock, mai de�erop co!artiss o1 m:croaes. h'wn� on the roct svrrace9, phlrn e•%V rerr4y2 c s.ryr.✓rcvrt po,Non or the n%rrooen p,�Aufonfs lror» fhe +anter 61r canverAlq ;f jo l:e�.l ofmosa"Wric rt%I oyan gos. 6'ranch cssernbly glued to ho 11,_ nF Vfa da d 0M.1 Dr oUliet tee, shcriened so bottom pi hronch ie Some as ront (fled to bottaT Qr role .M rcir+dec •x� e ! , 7'fr >� t 01) FefspeC#V6 v7em of i71C1 fee- m. nifola.. !r cc:,ri / 4 " s f r"f 1701 -MCI neiirmal f%Ui0 JrOnSiE^r l�'Pfl end view e/ Ion.4 portili9r7 {eek ` S DETAl1 S OF 7600 wrL ranlr, 1✓O7 r,l SCAlL" Jer3Diff�r Craig ©n—Site Sewage 1614 Woody Creek Rd. Soil Absorption System Ci >rptaker Residence 'Kahk Details 'itl�in County. Colorado f piiq??T dfop* Fir+ p.e. 'V nprrnOl oullel ht,le in enJ r 1 to,/, 1 baso i of elfec!. Ir�w g; ode ot'o.m o' Ivo. r :d 4o ly I I? ii lank ovl/el �etC'f � OlCnCG 4 6'O!U;e E+8gle Eye''ngitiftrk29 J0144 E..fvveJI AI, 12 PO veY,Co'lo'hdo kA31 l Cot o? go 02�96p nour. Throm F— E .�a70 MAV4 V.I— 201-79"374 T.: D..g Th— V0-4; TM— C--tl--V-- qpf 57u-uF5-24G5 P.6 p.g.5.ff Friery, AuOuat 21, 1838 727:28 )LM Clock jntet Ae;rafi 14FO-Al qeofe;ef;4e, or :'Vel- to —d in("bes of' Toi; Cover. AOR A,.4ZA1--,T 3.5 H F1 000 511-/.`W/"? ObCVe 100 Yr AOCAI-1-' fo tce of slope Jennifer Craig 1814 Woody Creek Rd. Curetolter Residence Pith -in County, Colorado On—Site Sewage Soii Absorption System Field Details Systcm Dcmgn: FFF. p.( - Eaffle Eye Engin-partV 10144E.. JeivellAv, '2 Deaver, Colpi-ado 80231 4" .7Chl 40 (C Z' in these 6�/:rr Q n,ppie-F, to ccv?trol / or Yo Ole— 4- disteibutio., pipe 4" pi'00,?g r'=dfbr3 aT pipe 14" 0" 0'4i glues �PO'--', E (P flo", R 0 Q), Jennifer Craig 1814 Woody Creek Rd. Curetolter Residence Pith -in County, Colorado On—Site Sewage Soii Absorption System Field Details Systcm Dcmgn: FFF. p.( - Eaffle Eye Engin-partV 10144E.. JeivellAv, '2 Deaver, Colpi-ado 80231 oot 07 99 02:37r Uou-e Threim From: F11MOrAM E&WO Eyt FW:303T65-W4 VON: 303.7654374 To. Qoup7nrom amyom Corouutuee 970-925-2465 p.1,6 p.y 5 on Tw•rpy S•p--0" Y 5:�St �m &9ie eye &9ineerin9 10144 Av., ##2, ! enver, Co. $0231 303--755-4374 engleyeCeeenteal-com ■ Doug Throm; Throm Construction 617 W. Main Street Aspen, Colorado 81611 FAX 970-925-2465 Sept 1, 1998 Ref` Jennifer Craig, Cabin Addition 1814 Woody Creek Road Woody Crack, Colorado Plan Modifications Dear Mr. Throm: (� The County Health Department has requested two modifications to the proposed design. These will not require any change to the drawing-, if you will simply make a note on the copies you have. They will also result in less cost because the cost of the added equipment will be more than offset by the cost of materials and labor for the item deleted. 1. Add to the siphon chamber: This will be in addition to the "Siphon Sitter" originally called for. 2. Delete from the infiltrator field: the Miran fabric covering over the chambers. Simply place the chambers at the spxified 3.5 ft minimum depth, and backfill with native soil in the manner recommended by the chamber manufacturer. Sincerely, Fax copy: Betsy Kipp County Health O INSTALLATION PROCEDURES FOR NORWESCO SEPTIC TANK EXCAVATION A. Backfill cover must range from 6'to 3010 avoid overexpansion of tank and possible leakage. m B.SidewalI allowance: 18' to 24'. r, Endwall allowance:l &' to 24'. Failure to comply with allowaneil ranges could cause tank ccl- lapse. C. Sand/gravel mixture, well - packed. 6' minimum in soil terrain, 12' minimum in rock terrain. ;OVER & MANHOLE EXTENSION A. Install cover and/or manhole [^ extension before you put water i in tank and backfill or cover may not fit. �fl B' Please note direction of flow: 11 inlet is higher than ouget. TEE GASKET INSTALLATION A. Installrubber gasket into preformed hub area. bJ`T —to „, - B. Install pipe through gasket and make connection to 4' —i reE sanitary tee. Use solvent weld cement to make connections. C. Put tees directly under ?kt�� rcooE manway/inspection boss. D. If the tank is equipped with an inspection boss, it can be cut open and a 6' pipe can be placed over the boss and extended to ground level for Inspection. BACKFILLING EXTERIOR 8 FILLING WITH WATER A.CAUTION: Start filling tank with water when you begin to backfill, ® keeping water level even with = backfill level as you go to prevent possible collapse. B.Backfill with 12' maximum thick ness layers of sand/gravel mixture, well -packed. ALWAYS COMPACT ENDS FIRST. C.Tamp and compact backfill under inlet and cutlet pipe. 5 BACKFILLING THE TOP OF SEPTIC TANK G`s When the septic tank is filled with water, backfill to the surrounding level. Maximum of 30'. MPORTANT TO CONTACT YOUR LOCAL OR STATE TARTAN REGARDING PROPER INSTALLATION OF SANITARY TEE ASSEMBLIES vont ! : 1 3/4l" 51` I f.M ^• J I SECTION AA 91 casiqmd By_ LEIWN -j. �'rrand function Pipe & Sp►ly CO. VOTE - m s drv+ring i41000 fv neo moneo•ioxx tnly, for 1 14 1000 GALLO N FRE—CASs CONCRETE I r 4 -,r -r ' ,r(7 A OVf.9OM a �i=dJlLlLtlm CA(IC x Pipe i� �h.:Id arsd ,r i- of 4Vr cuxl.rr - ana '9 net „ O.SEPTIC__.TAiJK p;'rwrt e� WITI'__..CAST j I �� P.a.$ox:M • 2868:70 BanIm Loov - - aenah4sd am FP A.sal«ml _ :nglneeri�y ;aqnPLACE _.IIoTE _ -£'i-- ..... __ ... _--___�__-------_�....�._.�__�_i «_�_ 6N P _ASCE BA F"U—t .,a �• Tt!epbm'37Moa •Pix 3 ro�ui 6&23 BiotubeO Effluent Filter Installation Operation and Maintenance FT0444-36 U.S. Patent Nos. 5294635 / 4439323 Installation Instructions: The Biotube Effluent Filter is suspended in the septic tank, supported by the 4" outlet pipe. The assembly is composed of a body that will be fixed to the discharge pipe and a removable cartridge that: consists of the biotube screen unit, the access handle and the vent. 1) Test -fit thO effluent filter on the 4" outlet pipe without gluing. Make sure that it fits plumb. Any existing outlet tee will have to bE removed. 2) Ensure sufficient clearance for servicing filter, but install assembly as snug as possible to the tank wall. If pumping from same compart- ment, allow sufficient room for septage pumping equipment. s- �z a tib' •�-: Orenco Systems Incorporated MAIM AVENUE SUTNERL ,OREGON 97479 (540 459.4 (800) 34891 EIN-FT-FTS-1 REV. 1.1 7/1/98 PAGE Maintenance Instructions How to Clean the Cartridge (Be sure to use protective equipment) Inspect the filter at least once a year, to ensure it is functioning properly. The filter cartridge should be cleaned if it starts toplug and whenever theta A is pumped. (A biological growth will occur on the filter. This growth is natural and should not be removed until clogging sufficiently impairs the discharge rate.) 1) Remove the filter cartridge by lifting it out of the vault. 2) Spray the cartridge tubes with a hose to remove any material sticking to them. Make sure the rinse water runs back into the tank. 3) Inspect the modulating orifices. Spray them clear of debris. 4) Ensure the red plugs are secure at base of cartridge. Clear the vent holes of any debris. Replace the cartridge. r vent holes 0 middle tube outlet hole a 9 EIN-FT-FTS-1 REV. 1.17/1/98 PAGE 3 February 19, 2013 Michael Craig Michaelcraigg66C)-comcast.net Onsite Wastekwater Treatment System (OWTS) Use Permit Inspection 1814 Woody (Creek Road (CDU) Pitkin Countyi, Colorado Mr. Craig, As requestedl, CBO Inc. performed an Onsite Wastewater Treatment System (OWTS) Use Permit inspection on the system serving the CDU at 1814 Woody Creek Road on February 12 and 19, 2413. The subject OWTS consists of a concrete 1000 -gallon two-compartment septic tank, a 500 - gallon single'' compartment concrete "de -nitrification" tank and a dosing chamber with a siphon. Effluent is dosed to an absorption area with two rows of gravelless Infiltrator® chambers, each row having 9 chambers each for a total of approximately 279 square feet of infiltrative area. A permit was obtained for the installation of this system and was documented in Pitkin County Environmental Health Department's electronic files; however, a paper file was unable to be found (Parcel ID # 2465-153-02-002). The owner was able to locate the proposed design packet, provided with the inspection report. The 1000 -gallon septic tank had a concrete inlet and an outlet tee with an effluent filter. The effluent filter''on the outlet tee was difficult to remove, so an extension was added. The septic tank was pumped between the first and second visits to the property by B&R Septic. The 500 -gallon "de -nitrification" tank had a lid on the tank, then a riser access to grade. The vent pipe extending from the tank inhibited access to the tank itself. A pipe connects that "de -nitrification" tank to the dosing chamber. The pipe coming into the dosing chamber was tilted upward, which indicates possible settling. While the system is still functional at this time, this pipe could become problematic if more settling occurs. The dosing siphon was tested and is (functioning properly. The absorption area showed no signs of saturation, and had no indication of failure. Observation ports were present. This evaluation is not a guarantee of future system performance.l, This inspection is good for one year. This report Ohould be submitted to the Pitkin County Environmental Health Department. The following] links are the required application and application checklist. CBO Inc. 33 Four Wheel Drive Road b Carbondale, CO 81623 t cell) 970-309-5259 office) 970-704-0484 cbo2610@yahoo.com February 19, 2013 Michael Craig Michaelcraigg66C)-comcast.net Onsite Wastekwater Treatment System (OWTS) Use Permit Inspection 1814 Woody (Creek Road (CDU) Pitkin Countyi, Colorado Mr. Craig, As requestedl, CBO Inc. performed an Onsite Wastewater Treatment System (OWTS) Use Permit inspection on the system serving the CDU at 1814 Woody Creek Road on February 12 and 19, 2413. The subject OWTS consists of a concrete 1000 -gallon two-compartment septic tank, a 500 - gallon single'' compartment concrete "de -nitrification" tank and a dosing chamber with a siphon. Effluent is dosed to an absorption area with two rows of gravelless Infiltrator® chambers, each row having 9 chambers each for a total of approximately 279 square feet of infiltrative area. A permit was obtained for the installation of this system and was documented in Pitkin County Environmental Health Department's electronic files; however, a paper file was unable to be found (Parcel ID # 2465-153-02-002). The owner was able to locate the proposed design packet, provided with the inspection report. The 1000 -gallon septic tank had a concrete inlet and an outlet tee with an effluent filter. The effluent filter''on the outlet tee was difficult to remove, so an extension was added. The septic tank was pumped between the first and second visits to the property by B&R Septic. The 500 -gallon "de -nitrification" tank had a lid on the tank, then a riser access to grade. The vent pipe extending from the tank inhibited access to the tank itself. A pipe connects that "de -nitrification" tank to the dosing chamber. The pipe coming into the dosing chamber was tilted upward, which indicates possible settling. While the system is still functional at this time, this pipe could become problematic if more settling occurs. The dosing siphon was tested and is (functioning properly. The absorption area showed no signs of saturation, and had no indication of failure. Observation ports were present. This evaluation is not a guarantee of future system performance.l, This inspection is good for one year. This report Ohould be submitted to the Pitkin County Environmental Health Department. The following] links are the required application and application checklist. An. Application: http://www.aspenpitkin.com/Portals/0/docs/county/Com%20Dev/EHNR/OWTS%20Use%20 Permit%20Application.pdf Application Checklist: http://www.aspenpitkin.com/Portals/0/docs/county/Com%20Dev/EHNR/OWTS%20Use%20 Perimt%20Application%20Checklist.pdf Please call with questions. Sincerely, 0 (. Q Carla Ostberg, MPH, REHS NAWT Certified Inspector Certification # ITC11042010 Exp. 2014 Inlet chamber of septic tank with concrete baffle. Outlet chamber of septic tank with effluent filter 2/12/13 2/19/13 photo taken after pumping and handle extension. Top of "de -nitrification" tank lid and vent pipe in riser Dosing chamber with siphon. See inlet pipe angled upward. Vent pipe "de -nitrification" tank Absorption area to the east of the driveway. • 11 wo ,rte ... ...... co,tc �4 P- < Ob