Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
pitkin.eh.264320403004 (2005)
Permit # 05051 Pitkin County Environmental Health Department Permit for an Individual Sewage Disposal System 0405 Castle Creek Road, Suite 10, Aspen, Colorado 81611 Phone 970-920-5070 / FAX 970-920-5077 Parcel ID # 2643-204-03-004 Type of permit New( ) Repair( ) Addition/Remodel to House( X ) Name of Owner Alan & Cherie Hassenflu Street Address 135 Turtle Cove, Brush Creek Property legal description Lot 22 Block 2 Filing 2, Brush Creek Subdivision Size 'of lot 2.407 acres Total square footage of the house 4300 Water source Brush Creek Community System # of bedrooms in house 5 # of offices, lofts & similar sized rooms in house Caretaker unit # of bedrooms in caretaker unit Total square footage of the caretaker unit # of offices, lofts & similar sized rooms in caretaker unit Designed for what # rooms (list) FIVE Bedrooms Permit information Designed by McLaughlin Rincon, Ltd. Mailing Address 111 P AABC, Aspen, CO 81611 Perc rate 30 Profile hole depth 8 ft Minimum Septic tank capacity 2,187 gallons Depth to groundwater or bedrock Minimum Absorption area Comments >8ft 1917sf/ 50% reduc=958sf Septic permit approved per compliance with the engineer design drawing and specifications letter dated Revised August 17, 2005. Any changes must be approved by this department and the design engineer prior to them being made.Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin County ISDS regulations. Design is for one 1500 gallon and one 1000 gallon septic tank in series, with a Biotube filter in the final outlet, and gravity flow with equal distribution to two systems of Standard Infiltrator units in trenches. Each system to have 4 rows of 8 units for a total of 64 units. There must be 6 feet of undisturbed soil between the trenches. The old system must be properly abandoned. This department does not endorse any brand of products. This permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an as -built letter to this department. This department must also be called for an inspection with a minimum of 48 hours advanced notice. *Revegetation over the area of the field is very important for the functioning of the system. Pitkin County has guidelines that must be followed to assure the plants that are introduced are appropriate for the conditions of the area. The use of native plants is strongly encouraged Permit approved by: t,6 �� Date: L Plans and specifications of the pr sed individual sew a disposal system have been reviewed and are considered satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was issued unless system construction has commenced or an extension has been approved in writing by the Department. As -built drawings must be included with,this permit before the final approval will be issued. Installer: Final approval: JL Date: 1 Jul 18 05 07:42a ;kin Co Env. Health (9-`)920-5077 PITKIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM 0405 Castle Creek Road, Suite 10, Aspen Colorado 81611 Phone (970) 920-5070 Fax (970) 920-5077 Name of OWNER AL� I S *\ 6* kc,6eMF LLk Owner's Mailing Address -�] 0 1 G AtZAeg� s `• City, State, Zip "mJVQN `TX' ")-] ©(�S Business Phone: Home Phone: 7 I b;41 E-mail Address: Primary Contact Person (all communication regarding this permit will go through this person) Name I -0M (0 Company 1 N L ' Contact Mailing Address LJ— SSC • S� G i�� Ci , State, Zi pc5 Business Phone: Cell Phone :- Fax : ^- 1 E-mail Address: Parcel ID # (available from assessor's office /' at 920-5160 or at www.pitkinassessor.org) Street address of property Legal Description: Lot CL ,Block .1. Filing a Subdivisipn �( US�j C Q¢ U )U.AIs� Size of lot: y0 7 acres. Type of proposed structure: -:S Total square feet of house T 3 6® # of bedrooms (potential) in house Caretaker Unit: Attached ( ) Detached ( ) Total areaCq . ft. of caretaker unit 0 # of bedrooms (potential) in caretaker unit Permit is for. New Home ( ) Repair due to failure ( ) Remodel/Addibon (j< ) Emergency use ( ) Water: Private well ( ) Spring { ) Stream ( ) Community/Public Water System ( ) If community system: Name of system The fee for a ISDS application is $600 for a permit that takes 6 hours or less for the department to approve. If approval takes longer than 6 hours, a rate of $100 per hour will be charged. The maximum fee is $1000. The basic fee of $600 is due at the time of application. The remainder, if any, will be due in two stages: first, at the time of issuance of the ]SDS permit; second, before final approval of the ISDS permit. Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information is true and accurate and that I have provided true and accurate Information on locations of all existing and proposed wells, contour intervals, buildings, property lines, ditches, slopes, waterlines, springs, suction or irrigation lines, drinking water cisterns, drain files, irrigation ditches, lakes, water courses, streams, floodplains, dry gulches, and existing septic systems. I hereby certify that any such features not shown on attached site map are not present. Issuance of the permit does not imply the approval of any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all approvals and permits have been obtained. The Pitkin County Environmental Health Department, Pitkin County and employees of these agencies will be held harmless should the individual sewage disposal system fail or malfunction. The permit to construct is issued on Information submitted by the applicant or his/her representatives. The owner assumes full responsibility in case of failure of the system. Signature of applicant Received by G:lisdslisds applic\lsdsapp Rev050103.doc Date Receipt # I t ! Date P.A IMA 0 Q- e --c Iv awll slel}lui ua�el eq o} uoi}oy / s}uawwoo I of ua� odS uosiad I ale(] :ssaippy #al laoaed :aweN }says bol }oe}uo7 }uawpedaa y}IeaH le}uawuoainu3 A}unoo ul�}Id `"1 Pitkin County Environmental Health Department Contact Log Sheet Name: E Lk, Parcel ID#: Address: Date Person Spoken To Comments / Action to be Taken Initials ITime ft-n(�M,irlQa C61 v I P. 1 * * COMOCATION RESULT REPORT ( OCT. 11. 2 9:31AM ) * * * FAX HEADER: ENVIRO HEALTH NAT RESOURCE TRANSMITTED/STORED : OCT.11.2006 9:28AM FILE MODE OPTION ADDRESS RESULT PAGE -------------------- ------------------- -- - ------------ ---- 700 MEMORY TX 9258780 OK 2/2 9251974 OK 2/2 ---------------------------------------------------------------------------------------------------- REASON FOR ERROR E- 1) H A N G U P OR LINE FAIL E-2 BUSY E-3) NO ANE-4) NO FACSIMILE CONNECTION PITKIN COUNTY ENVIRONMENTAL HEALTH & NATURAL RESOURCES DATE: 10/11/2006 Send to: Ian Long From: Alicia Gomez Fax Number: 925--8780 Phone Number. 920-5087 CC: McLaughlin Rincon Number of Pages, Including Cover: 2 CC Fax Number: 925-1974 O URGENT O REPLY ASAP O PLEASE COMMENT O PLEASE REVIEW IRI FOR YOUR INFORMATION CO M M F_NTs: Septic Permit 4,05051 for parcel 2543-204--03-004, owner Hassenflu, has been finalized. Please feel free to call 920-5070 if you have any questions. fax cover Pitkin County Environmental Health and Natural Resources 0405 Castle Creek Road Suite #10, Aspen, CO 81611 Phone (970) 920.5070 I Fax (970) 920.5077 Web Site www.aspenpitkin.com/ehnr C u jima@co.pitldn.co.us, 04:32 PM 8/18/2005, Hassenflu- 135 Turtle cove -okay for building permit issuance To: jima@co.pitkin.co.us From: Nancy MacKenzie <nancym@co.pitkin.co.us> Subject: Hassenflu- 135 Turtle cove -okay for building permit issuance Cc: Bcc: Attached: Hi Jim, Sorry to be back to the old way of doing things, but I like to get them going on this permit. The engineer just walked in with the necessary changes to the septic design. So I won't have time to issue the paper permit until I get back. And Alicia is gone for the day. Hope it isn't a problem for you. Printed for Nancy MacKenzie <nancym@co.pitkin.co.us> 1 Nancy Mackenzie From: Nancy Mackenzie Sent: Thursday, December 22, 2005 9:22 AM To: Jim Austin Subject: 135 Turtle Cove - Hassenflu GARAGE Jim, We are okay with the issuance of a building permit for the unheated garage with no plumbing. The garage location does not interfer with the location of the septic system. 12/22/2005 TRAUTi rER•LONG INCORF"�RATED BUILDING CONTRACTORS 315 E. HYMAN ■ ASPEN, COLORADO 81611 970.920.1414 ■ FAX 970.925.8780 1 RECEIVED DEC Z 2-2005 PI !'KIN COUNTY ENVIRONMENTAL HEALTH G � \ CIF'? 1 RECEIVED DEC Z 2-2005 PI !'KIN COUNTY ENVIRONMENTAL HEALTH 0 0 Laughlin Rincon `nginedring design ;onsulting McLAUGHLIN RINCON Ltd. 111 P AABC ASPEN, COLORADO 81611 970-925-1920 970-925-1974 fax mweaspen*of.net MEMORANDUM Date: September 8, 2006 To: Pitkin County Environmental Health — Carla Block From: Dean Derosier; McLaughlin Water Engineers, Ltd. RE: HASSENFLU Septic System - 49 Turtle Cove — Brush creek Village PCEH Permit # 05051 This Final Approval letter is written for the new septic system and the associated permit that serves the Hassenflu Residence at 49 Turtle Cove in Brush Creek Village. The system was designed and installed and placed into service in the summer of 2006. PCEH, and GDD inspected the installation of the system and found it was installed according to MR's design and PCEH requirements. This letter is to serve as the acceptance letter for MR and recommendation to Pitkin County for final acceptance of the system. To my knowledge and per my inspection, the System was installed according to MR and PCEH standards and the system layout was installed per the revised design dated May 30, 2006. The system consists of 1-1,500 and 1-1,250 gallon tanks and 2 infiltrator systems. Each OWS has 5 rows of 8 infiltrators in each row, (40 in each system and 80 TOTAL). One system is located below the house and the other system is located below the road. Attached is an asbuilt of the system as installed. A visual test was passed on the pumping system to insure all rows of infiltrators in the Mound System were distributing effluent evenly. Please call is�you have any questions. G. D --y- Derosierr P. it EME 30 06 10:20a WL6ughlin Rincon Laughlin Rincon �— or+.1raPr-nq dcsi,n =o nsuIVing Date: May 30, 2006 970-925-1974 is P.1 McLAUGHLIN RINCON, Ltd. 111 P AABC ASPEN, COLORADO 31611 970-925-1920 970-925-1974 fax mweaspen@rof.net MEMORANDUM To: Nancy M - Pitkin County Environmental Health; From: Dean Derosier; McLaughlin Rincon, Ltd. RE: Hassenflu Residence - Septic System Design Notes — 49 Turtle Cove in Brush Creek Village — UPDATED DESIGN INFO: Due to the contractor installing the infiltrators 8 feet apart instead of 10 feet and not having 6 feet of undisturbed soil between trenches, the design of the system needs to be modified. Since we do have 6 feet between the trenches we do not have a typical bed or a typical trench system, but a hybrid so speak. The design and soils do not warrant the redesign of the system based upon a bed system but does not have enough soil between trenches to meet the requirements of a trench system. I recommend that we add another row of infiltrators, spaced 10 feet apart from the previously installed rows, to the system. This would effectively increase the size of the system by 25% not the 30% increase that the bed design would require. The total number of infiltrators would increase from 64 to 80 units in 5 rows of 8 infiltrators. We will also install the two items you requested tees in the first tank per the regulations and the installation of larger baffled distribution boxes to evenly distribute flow to each of the 5 (Five) rows of infiltrators in each system. Area of Septic field required = A Percolation Rate = 30 minute per inch A=Q/5 x SR of the Perc Rate 1,750/5 X SR of 30 = 1,917 square feet 15.5 Sq ft per unit = 123 infiltrators1-4 Wyk-, McLaughlin Rincon Ltd. 2300 15" Street, Suite 220, Denver, Colorado 80202 P 303-964-3333 F303-964-3355 May 30 06 10:20a McLaughlin Rincon 970-925-1974 p•2 0 Pitkin Cou ty allowance = 30% for use of infiltrators in a bed system A- 958 SF or 86 units I recommend increasing the size by 25% (16 total units) Change to 80 total units — 5 rows of 8 infiltrators in two systems. Add an additional row of 8 infiltrators to each system. G. Dean Derosier, P. E. gd&Hassenflu2 McLaughlin Rincon Ltd. 2300 15'" Street Suite 220, Denver, Colorado 80202 P 303-964-3333 F303-964-3355 McLAUGHLIN RINCON, Ltd. I I I P AABC ASPEN, COLORADO 81611 970-925-1920 970-925-1974 fax mweaspen@roinet MENI DU . RF Clete August 'I7, 2005 oQ�00 To; Pitkin County EnvironmentalHealth; : Q w 25012 From: Crean rosier; l�lo'Laughlin Rincon, Ltd s ,� RE Hassonflu Residence - Septic System Design No W41� �� - Eve in Brush Greek Village - REVISED The following are my design notes for the Remodel of the Hassenflu Residence. The existing OWS, located just below the haeme is old and is to be abandoned in place. Over the years records shown two additions to the system. Investigative excavations found the existing system to be plugged and not working. The new system will completely replace a old system. 5 — Bedrooms - Approx. 5,000 Square Feet of living area -100 gallons per day per person - Per Rates 30 MPI By GDD - Ground wter 500'+1- feet from surface not encountered - Public Wa er System - Existing System — 1-1,000 gallon tank, which will be abandoned / Flow = Q = � bed rooms x 2 peo/br x 100 gal/day/per x 1.75(max flow) = 1,7550 gallons per day. / Tank sizing - 5 - Bed Rooms requires 2,187 gallons of septic tanks; Q X 1.25. Install two new tanks — 1- 1,500 gallon tank and 1- 1,000 gallon tank for a total of 2,500 gallons. The new double chambered tanks shall be located in series below the existing home and will be installed in the general area north of the home in the open area. A minimum drop of 3" is required between tanks. Tees will be installed on both the influent and effluent lines of the tank; set on the inside of the tank. Set top of line from tee within 1" of the roof of the tank and extend line downward 14" below centerline of tee. McLaughlin Rincon Ltd. 2300 15`h Street, Suite 220, Denver, Colorado 80202 P 303-964-3333 F303-964-3355 Maximum cover over access to tank shall be 6" and easily accessed for maintenance. Asbuilt location of the tank lids for future maintenance. Do not bury tank access lids. Bedding illor'lscreened rockkarou'nd the tanks be e compacted to 95%. installation of native outside the bedding zone is acceptable. Fill tank with water prior to backfill to check for leaks and leave water in tank for placing the system in service. Septic tank will be two -chambered tanks. Install an OSI 4" diameter Biotube, or equal, inside the new 1,000 -gallon tank's effluent line. The housing is to be 36" high with a cartridge length of 28", using SDR 26 PVC piping. Piping from the home to the tanks will be 4" SDR 35 PVC laid at a minimum of 1%. Insul tis with less than 42" of cover or in uninsulated crawl spaces. Minimum depth is 3.5' for all piping. Install cleanout between house and septic tank. Use standard 2" Blue BOard clon led 6" above all pipelinesthe pipe and laid to and from the on a flat bedding surface if less then 3 5' of overon septic tanks,. Install cleanouts between the home and septic tanks. I Area of Septic field requiredA 11 Percolation Rate = 30 minute per inch A=Q/5 x SR of the Perc Rate 1,750/5 X SR of 30 = 1,917 square feet 15.5 Sq ft per unit = 123 infiltrators Pitkin County allowance = 50% for use of infiltrators A- 958 SF or 62 units – (98 Quick 4's) (9.8 sq ft/unit) The design will separate the new system into two separate and similar sized trench systems, one above the road and one below the road. This is a gravity feed system using infiltrators and serial distribution. No pumping or dosing system is proposed. Each system will have 32 units in 4 rows of 8 units. We will use Infiltrator Standardsanits. Total length of each trench is 48 feet long. Total 64 infiltrators in two trench systems. Each trench will be stepped down and offset slightly to fit the site.. (Infiltrator Quick 4 could be used as well -Quick 4's are required, 4 rows of 13 infiltrators in each system OR 102 TOTAL). The advantage of Quick 4's is they work better on sites that require curved rows. Distribution line to the field from the tank and in between the trench systems shall be 4" SDR 26 PVC. Install cleanout between home and the first tank and if any line between tank and the system exceeds 100 -feet in length. All pipe bedding to consist of a minimum of 2" under and 6" over the pipe of native soils with McLaughlin Rincon Ltd. 2300 15'h Street, Suite 220, Denver, Colorado 80202 P 303-964-3333 F303-964-3355 maximum sized material of 1". Remove all burrs, excess material, and other debris from drilling the perforations in the pipe. Rake trench bottoms and sidewalls prior to installation of infiltrators. Install a splitter box with a baffle to evenly distribute flows between the two systems and again at each system to evenly distribute flow to each row. System location to be field determined to reduce tree and vegetation removal, site conditions, and maintain setbacks. Contour the trenches to fit site conditions and the topo of the site. Trenches are to be 10' apart. Minimum depth= 12"; maximum depth = 36" to top of infiltrator. Install access ports/vents on each row of trenches. Use collar on vent as it penetrates the infiltrator to insure pipe does not drop into infiltrator. Move vents on existing system to end of additional rows to be added. Trenches to be with in 2,of level across the entire length of each row. Install splash plates under the entry and exit piping at each end of each row of infiltrators. (Splash Plate - 1' Wide and 18" Long). Adjustments to fit existing site contours and conditions may be made per approval of the engineer and homeowner. Minimal tree and vegetation is to be disturbed during installation. The engineer shall finalize elevations of the tank and trenches in the field. Installation and operation shall be approved by the engineer prior to final acceptance. The existing septic field is to be abandoned in place as part of the contract to install the new system, including the existing septic tank. Contractor to dispose of all materials per Pitkin County Regulations. Care is to be taken working around the existing system, not to disturb the system. System must meet all Pitkin County ISDS requirements and MRLtd. design standards and must be inspected by MRI -td. and Pitkin County prior to Final Approval. Owner is recommended to pump the septic tank at 2 -year intervals and change the Biotube. Landscaping and watering us on top of septic field shall be minimized or eliminated. Owner is to pump the existing tanks as part of the permit for the new system. The septic system installation will be inspected by both Pitkin County and MRL. Provide adequate notice for inspections. We will both need to inspect the tank installation, distribution piping, new infiltrators, splitter box. See attached ISDS Completeness form for more information on installation requirements and information needed for asbuilts. The contractor or installer is responsible to supply the Design Engineer and County with asbuilt information prior to final acceptance. G. Dean Derosier, P. E. gdd\Hassenflu 1 McLaughlin Rincon Ltd. 2300 15" Street, Suite 220, Denver, Colorado 80202 P 303-964-3333 F303-964-3355 Laughlin Rin ongineerinq dt sitgn aOnst""ng McLAUGHLIN RINCON Ltd. I 1 I P AABC ASPEN, COLORADO 81611 970-925-1920 970-925-1974 fax mweaspen@rof.net MEMORANDUM Date: July 14, 2005 BY: Dean Derosier P.E. ; McLaughlin Rincon, Ltd., RE: hASSENFLU Septic Design Property Address: 49 Turtle Cove — Brush Creek Village Legal Description: Property Owner: Hassenflu Percolation Information: Ground Water @: No Hole Depth: 36" to 42" Depth to Water: 500'+ Sand\Gravel: No Presoak:Yes - 6/22/05 tions: SlNo Amt of Water: —3 gal 2% Sloope:pe: 2 Bedrock @: Unknown Depth to Rock: unknown small and cobbles- Broken and Type: Fractured rocks in a clayey loam with gravel fractured shale at about 8'feet. Percolation Tests: Date and Time: 6\22\05 2:00 pm Hole # 36„ 42" 3 36" Depth Presoak yes yes yes Remaining 10min 10min Time 2hr Interval 2hr 2hr 2hr Length 10 20 40 Percolation Rate A fourth hole had a percolation rate of 30 MPI Avg is 25 MPI, However I am going to use the DESIGN PERCOLATION RATE of 30 MINUTES PER INCH Soil Profile Hole: 0-1.' Topsoil Light Brown. 1.0 to 7.5' - Sandy Clay with gravel and cobbles, Light grey 7.7 to 8' Datk��c+lays �.;.g��gls some broken shale ADDRESS: 111 Aspen, CO. 81611 970-925-1920 -1, PITKIN ENVIRONMENTAL HEALTH DEPARTMEN-f ISDS DESIGN CALCULATIONS Owner's Name Parcel ID # House Size (sq. ft.) 41.. (75 gpd, 100 gpd, or 130 gpd) 100 Number of Bedrooms in Main House Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House Number of Bedrooms in Detached Caretaker unit Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit° ,w (If the caretaker unit is ATTACHED, treat as if part of main house.) Average Daily Waste Flow 1000 State Review Required? no Perc Rate -`` 1 (T) Design Flow (Q) = # potential bedrooms X 2 people/bedroom X gpd X 1.75 Q= 1750 Minimum tank capacity 2187.5 gallons Absorption Area (=Q/5 X SQRT perc rate) A = 1917.029 sq. ft. of absorption area required 124 gravelless chamber units without reduction # of Perc Holes Required: 3 1 in every soil type? Spaced uniformly over proposed area? QUICK 4 9_8 A = 958.51448 sq.ft. with 50% reductionTRENCHES 98 gravelless chamber units with reduction STANDARD A= 958.51448 sq.ft. with 50% reductionTRENCHES 62 graveUess chamber units with reduction L 36 60 EQ36 units in TRENCHES SETBACK FROM WELL # of feet = 160 SETBACK FROM POND, STREAM OR IRRIGATION DITCH # of feet = 110 SETBACK FROM DRY GULCH # of feet = 85 QUICK 4 9.2 1341.9203 sq ft 30% reduction BED 146 chamber units with reduc. 1341.9203 sq ft 30% reduction BED 87 chamber units with reduc. 107 EQ36 units in a BED -M a • �►1 /'rte. I Aspen / Pitkin Environmental Health Department Contact log Sheet Name: o ba,!4,#,s Jo Parcel ID#: Gz/3 -�O�f - 03 00 Address: u r4/z 1�r Creek Ui ll Date Person Spoken To Comments / Action to be Taken Initials s"l0- S � 5 f ro s en sv! ` pro*ed t3K a] ?Brush Greek Village, Piling 2 as in Plat ;Jerk and Recorder, Pitkin county, 1% 1 X17 s"0 a client request for an existing / 2505206" W the line between found subject parcel with the southerly / 9 159018, the northerly monument being a the top of a survey monument stamped / the subject parcel / � t search by this surveyor to determine )ther encumbrances of record. The Under Ground Utiliti 15ements are based on the plats t�' '---, �\— cable, Phone the time of this survey A vey include: Replat of Lots 21 and 22, as recorded in Plat Book 6 at Page 30 'ded as Doc. No. 104586 FIRETRUGK TURNAROUND LOGATI( MOON, ASPEN PROTECTION DISTRICT, AY TO BE REMOVED PROP5ED GRAVEL \ / DRIVEWAY ABANDONED \ ' 0\ \ \� Under,Groueid utilities g,urvey Monument ElecCric, Cable, Phone and Gap 'ed NEW 2 -GAR UNHEATED/UNINSULA } TED GARAGE (768 5F OF FAR TO BE ADDE7, �GHP�GES- Q TOS MIT TO ` \ \ \ PER R�cJti>EµGE �, i Edge of Pond THE t'If'` pool C' \ EDGE OF EXI5TIN6 DRIVEWAY TO BE ABANDONED �� �Gonorete Pads � + / EXI5TIN6 GARAGE TO BE REMOVED (517 5F OF FAR TO BE REMOVED) RECEIVED DEC 2 2005 e / 0 PITKIN COUNTY \ Planter sox, \ ENVIRONMENTAL HEALTH \ N � 1— -``fid. Si�,P've}-Manument \ Rebr and Gap stamped-Le--�g4l nra3o�3'�o"w 1Oa.Sa 77.70' ® T.B.M.= 100.4 C�-� J�Pp niter. 2 /NF/L 7RrOR 6*r67E 6 IN5T,4LL L/AE FROM - E40N rO 14A VE 5 TANK TO EA04 FIELD RCl 6 CF 8 aACK 4 Al-ON6 ROAMA r UN/75. 48 ' LONC ouT5/DE OF ELEcr LINE, EVEN 016TRlauT/ON O IN5 rAU ZX5 TR/Bcl r/ON EACN RM 90 rO ,4L BOX WM14 a499L E ,4N0 /NF/L r? e4 rO 1; ( Al /ND/Y/L7UAL FIFIN6 TO EACA4 6*r6M1`'I). INV' T VA �ELS ,CCN RGY,�J TO EYENL �'' ANO LOC,4 WN/ OF ,p/51�'/,Su1� FLG�IJ E.4C,�1 ROIU To �� FILED CEM RMINED. , W 5 rS= E4CILI RCW 0CWN TO MA rCN CONTOURS � ,4ND OFFSET .45 N z"� rO AV010 - VE6EU TrON. /- Mr D/571RUaANCE CF 7REE6, IN67ALL SCN 40 PVC SETi',UEEN Di57RBurroN BOX ANO /NFIL 7RR.4 rCR 11\16rAL - D/57RIOU7"1ON RCU6 AND BEMESIV �eG� BOX W171*4 aAFFLE TO IRCYI/S OF /NF/L 7RATORS EVEWr L"%&T RIEU7E .37' J �t FI -CW TO E4CI4 5Y57EM, t USE TEES TO EVENL r Jae 016 7R/BCl7E FL -CW To N E404 SYSTEM CF ,� /NF/L 7? P, rORS k CV l T /5 / T/ON NS AL1- D 7if OI .� 8 BOX WITN aAFFL.E AA10 A101111OUAL F/FINC rO EACq RCS!/ rO EVENL 0 D/5 TRIM7F FI -CW o INS rAL.L TU O AEW 8 o, DBL C�IAMI'10EJ�D 8 0' SEFr/C rANK5 - 1- 20' 1,500 ANO l- 1000 — 6AL.LON /N 6ERIE5 0 Wlrq rqE 1,500 F/RS7; 0 IE ro BE FEL.O VERIFIED, 1N5rAL.L 4 " IS' 05/ B/07UlSE /N OUL.ET CF 1, 000 0 GALLON UNK O 'go INST,4LL SDR 26 Fnd. Survey Monument Under Ground Utilities f'lf'INC FROM TIE Io1v1� rO r�l� r,�NK Rebar and Cap Electric, Cable,hone AND aE7UEEN UNK5 Stamped LS 2376 INS r,4L-L CZ FAN r A r oUTS/L� of SME- Woo tees W/ Planters Spot Elevation on the Deck = 99.66' \ at the NW corner of t1ouse 0 PERCOL4 i/01 q NOLE bs, F20F1!_,E HOLE WA 72 SUPPL *r l5 A Pual-/C 5 r57EM -I- Electric Electric Meter 30 0 30 60 lan ter 1 inch = 30 feet 92 40.7 2 Story v, Wood Frame Dwelling E Wooden Deck Nq 0 8.0' i?der Ground Utilities ale, . Phone 2 /NF/L 7RrOR 5*'6 1* - E4CI-1 To 14A VE RMS CF 8 QJ/CK UN/T5, 48' LONG W1771 EVEN 057ROC1T/ON T EAC14 RCW 60 roraL- /NF/L 7R4 rORs, (40 /N EACLI 5*'57E/1, 92 EX16MCI SBPr/c r, ANO F/ELD 10.45 ABANDONED /N RL IN6r,4L.L AN IN )9CRT A r rl-IE RECONF/CUURE ROA n: �) MAKE SHIRE A'67EI'9 /S CY,1r5/LE o_ o� c� n D o� K03 CD < , ZACr LOCA L A IrOUr of T EXIS rINO $19 1-' Sub Floor Plywood AN47 FIELD /S Un Elevation (9 Entry orth Side of House = 00' Spot Elevations / Taken in Planter = 96.06' for NE corner of house and SE corner of house= 96.36' Concrete Plan ter Box F Pond =9 1.30 U1ATR L .,Q6, REVJ TANK AuOusT /7 EXISTING AND FUTURE GROUND BACKFILL - 3'MINUS MAX. 6' - TOP SOIL BEDDING ZONE - FINE NATIVE MATERIAL NO LARGER THAN V IN DIAMETER WITHIN 6 ' OF INFILTRATOR vvv vv vvvvv vvvv 40 =fit PVC PPM TO rINFILTRATOR En W Di1LTN M TfMCMDWALL am TEE AT 104CH Tf+IE = / /CJ/VI ' SPLASH PLATE OF 2 SYSTEMS OF INFILTRATORS EACH TO HAVE 4 - 32 - FOOT QUICK 4 INFILTRATOR TRENCHES - 8 UNITS IN EACH TRENCHES. IE TO BE FIELD DETERMEINED MINIMUM DEPTH IS 3 -FOOT TO BOTTOM OF TRENCH, 8' APART MINIMUM IE TO BE FIELD DETERMINED BY ENGINEER TRENCH DETAIL — NTS Number Revision Description By Date 49 TURTLE COVE Laughlin Ri ncon DETiAIL: PROJECT NUMBER Drawing Number: HASSENFLU SEPTIC ASBUI LTSCHECK: 05-50-01 OWS-1 BRUSH CREEK VILLAGE "IP c1`.~ ` a„ ",1, PH. 970-925-1920EFax 970-92511974 DATE: JULY, 2005