Pitkin County Environmental Health Department
Onsite Wastewater Treatment System (OWTS) USE PERMIT
Permit for Continued Use of an Existing OWTS
76 Service Center Road, Aspen, CO 81611
Phone: 970-920-5070 Fax: 970-920-5077
www.aspenpitkin.com/EHNR
Parcel ID #: 1 2645-034-01-007
OWTS Use Permit #:
I 0029.2017.POWU
Date Issued: 4/25/2017
Issued By: Bryap Daugherty
Expiration Date: 4/25 18
Owner(s): I Steve Brammell Trust
Property Address:
1000 Lazy O Road
Legal Description:
Lot 7, Lazy O Ranch
Licensed Inspector:
C rla Ostberg
Inspection Date(s):
31(20/17
SYSTEM INFORMATION
Components
Type
Capacity/Size
Primary Treatment Unit
Concrete single compartment tank
Concrete single compartment tank
2500 gallons
1000 gallons
Secondary Treatment Unit
Advantex AX -20
Absorption Area
Geoflow Driplines
6 zones (11,375 ft2 total)
Other System Components
Pump
®In use at the time of the inspection. ❑Not in use at the time of the inspection.*
*If the OWTS was not in use t the time of the inspection, it is recommended that the system be re-evaluated when it is in use for a more accurate
evaluation of the system.
System Records:
Permit #: 04072 (Date of Issuance: 10/15/04 Date of Final Approval: 7/27/06
# of Bedrooms or fixtures served by OWTS: System is designed to serve 5 bedrooms
Operational Status: According to the observations of the inspector the system was functioning as designed. The
advanced treatment system did not have a maintenance agreement at the time of inspection but is now in place. The
field area did not show any signs of failure. Repairs were made to the Advantex Pod lid, and the effluent filter.
Inspector Recommendations: N/A
Department Recommendations: Annual maintenance
Issuance of this OWTS Use Permit is based solely on the conditions observed and reported by the inspector to the Department on the date of the inspection(s) and
on Department records at the tilne of permitting. The issuance of this permit does not constitute a guarantee, warranty, or representation by the Department
that the system will operate properly or will not fail or that the system will not be subject to future enforcement action to correct non-compliant conditions.
Estimated capacity of the system has been listed on the permit and we recommend that you monitor and/or meter water use to prevent overuse and possible
failure.
Pitkin County Environmental Health Department
Permit for an Individual Sewage Disposal System
0405 Castle Creek Road, Suite 10, Aspen, Colorado 81611
Phone 970-920-5070 / FAX 970-920-5077
Permit # 6`i6� Parcel ID # 2645-034-01-007
Type of permit New(X ) Repair( ) Addition/Remodel to House( }
Name of Owner Steven & Alison Brammell
Street Address 1000 Lazy O Road, Snowmass, CO 81621
Property legal description Lazy O Subdivision
Size of lot 7.83 acres Total square footage of the house 8,400
Water source Community/Public Water Svstem
# of bedrooms in house 3 # of offices, lofts & similar sized rooms in house
Caretaker unit Total square footage of the caretaker unit
# of bedrooms in caretaker unit 2 # of offices, lofts & similar sized rooms in caretaker unit
Designed for what # roo.. s (list) 5 total .= 3 house+2 future caretaker (2'people/BR, no room used as a bunkroom)
Permit information
Designed by Gamba & Associates
Mailing Address 113 9"' St, Suite 214, Glenwood Springs, CO 81602-1458
Perc rate (80). Profile hole depth 9 ft Depth to groundwater or bedrock > 9 ft
Minimum Septic tank capacity 2,844 gallons Minimum Absorption area * see engineer design
Comments
Septic permit approved' per compliance with the engineer design and specifications stamped and revised
09196104. Any changes must be approved by this department and the design engineerrp for to them being made.
Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin
County ISDS regulations.
'Because of the slow percolating soils, the design is for a drip dispersal system based on an LTAR rate of 0.2.
There is one 2,500 gallon tank followed by a 1,000 gallon tank with two Advantex AX -20 filter modules. Both tanks
are single compartment, concrete tanks. The field is six zones of Geoflow driplines for a total of 5,700 lineal ft, for
an effective area of 11,875 sq ft. There is a two foot separation between each dripline. Driplines are kept shallow,
but must be a minimums of 12 inches below the surface of the ground.
This department does riot endorse any brand of products. This permit must be kept on-site during installation.
The engineer must do a final inspection of the installation and submit an as -built letter to this department. This
department must also be called for an inspection with a minimum of 48 hours advanced notice.
'Revegetation over the area of the field is very important for the functioning of the system. Pitkin County has guidelines that must be
followed to assure the plants that are introduced are appropriate for the conditions of the area. The use of native plants is strongly
encouraged.
Permit approved by: Date:
Plans and specifications of the oposed individual sewage disposal system have been reviewed and are considered
satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin
County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was
issued unless system construction has commenced or an extension has been approved in writing by the Department.
As -built drawings �m.y}�+st be included with t s permit before the final approval will be issued.
Installer:i.��ticcc�a;` > a'h
a :a T.
+
. . ..........::
Pitkin County Environmental Health Department
TIK 1111 Onsite Wastewater Treatment System (OWTS)
CO U ill TV
USE PERMIT APPLICATION
76 Service Center Rd
4 - Aspen, CO 81611
http://pitkincounty.com/248/\Nastewater-Treatment
Application for Continued Use of an Existing OWTS
0
Parcel I D# (available from the Pitkin County Assessor's Office
2645 034 01 007
970-920-5160 or at http:ilpitkinassessor.org/assessor/search.asp
Aspen Snowmass Sotheby's
Purpose of Use Permit:
PROPERTY TRANSACTION
®REMODEL/
Property Address:
sbrammell@yahoo.com
Owner's Mailing Address:
1000 hazy O Road
Cell Phone:
Lot:
Block:
Filing:
Snowmass
Subdivision:
81654
Home Phone:
7
Business Phone:
[Lazy O Ranch PUD
Residences:
Other
# of Bedrooms:
5 fixtures/uses:
Property Owners)*:
Terry Rogers
Email Address:
Aspen Snowmass Sotheby's
Contact/Applicant Mailing Address:
Stev Brammell Trust
sbrammell@yahoo.com
Owner's Mailing Address:
City, State, Zip:
Cell Phone:
(970) 379-2443
Business Phone:
000 Lazy O Road
Snowmass
CO
81654
Home Phone:
Indicate Preferred Method of Payment
Business Phone:
contact information must pe provided for the owner signing this application.
Primary Contact Person/Applicant (if not owner):
Terry Rogers
Company:
Aspen Snowmass Sotheby's
Contact/Applicant Mailing Address:
City, State, Zip:
Cell Phone:
(970) 379-2443
Business Phone:
Fax Number:
Email Address:
carla.ostberg@gmail.com
Indicate Preferred Method of Payment
Check • Credit/Debit U Cash
Licensed Systems Inspector: Phone Number: Email Address: Fax Number:
Carla Ostberg (970) 903-5259 carla.ostberg@gmail.com
Mailing Address: CitV, State Zip:
33 Four Wheel Drive Road Icarbondale 100 181623
PLEASE READ BEFO. _1GNING:
certify that the above information is complete and accurate and that I have provided complete and accurate information in all of the documents
ncluded in my application package. I acknowledge that this department may revoke any permit I am issued if my application is found to contain any
naccurate, false, or misleading information.
Owner Signature (Required): Date:
Stephen Brammell 3/25/17
Applicant Signature:�arla OStberg 3�4'�� Y 4`:r� ty C::� � G c••a Date:
17at`.t 17si3.2•. 14 24.36
Please allow 3-5 business days for processing of Use Permits. Save Form Clear Form Print Form
FOR OFFICE USE ONLY
Received by EH Staff: Fee & Receipt #: Date:
Effective ants IAW2017
March 24, 2017
Steve Brammell
sbrammell(awa000.com
Onsite Wastewater Treatment System (OWTS) Use Permit Inspection
1000 Lazy O Read
Pitkin County, Colorado
Steve,
As requested, �BO Inc. performed an Onsite Wastewater Treatment System (OWTS) Use Permit
inspection at 1000 Lazy O Road, Snowmass, Colorado on March 20, 2017. The legal description of the
7.83 -acre property is Lot 7, Lazy O Ranch Subdivision.
The permit andidrawing of the proposed system' was provided by Pitkin County Environmental Health
Department (Parcel ID #2645-034-01-007). The subject OWTS consists of one 2500-gallon2 concrete
septic tank followed by 1000 -gallon concrete septic tank that serves as a re -circulating tank with the
recirculating splitter valve (RSV) and recirculating pump. Effluent gravity flows to pump vault located
downhill and west of the residence, east of Lazy O Road. The Geoflow@ headworks is located near the
pump vault. Effluent is pumped to an automatic distributing valve (ADV) located just south of the
driveway. The Geoflow® drip line or soil treatment area (STA) is located in the open field south of the
driveway and east of Lazy O Road. The STA consists of six zones, each with 5 drip lines, 190 -feet long
for a total of 950 feet of drip line in each section. Individual Sewage Disposal System Permit 04072
documents thisi system. The system was sized to accommodate 5 bedrooms. The permit received
final approval on July 27, 2006.
This system has advanced treatment technology and requires routine maintenance. We understand
there is no pass or current maintenance contract on this system. A maintenance contract must be
secured for cgntinued operation and maintenance of this system. We recommend Valley Precast
out of Buena Vista for this work.
A clean out is located to the north of the residence. A manhole access, which has 10 -feet of risers,
provides access to where the sewer line from the main house and sewer line from the caretaker dwelling
unit (CDU) come together. This manhole access appears to have an accumulation of some debris, but
flow through the access appeared normal. The septic tanks and two AdvanTex® AX 20 pods are located
west of the residence, just below the driveway. We believe the first septic tank in the series is 3000 -
gallons. This septic tank has both inlet and outlet tees. The septic tank was pumped by Altitude Septic
at the time of toe inspection. There was a significant amount of debris flowing over the inlet tee prior to
pumping.
Half of the volume of the septic tank housing the RSV and recirculating pump was pumped at the time of
the inspection. The pump truck was full and can return for completion of pumping, if necessary. We did
leave some effluent in the septic tank in order to run the pumping system safely during maintenance.
The effluent filter was extremely clogged and was cleaned at the time of pumping. The RSV was also
' Note that we did not receive a "record drawing" for reference. All notes on the drawing indicate "proposed"
components.
2 Pumping indicates this septic tank is more likely 3000 -gallons.
CBO Inc.
33 Four Wheel Drive Road
Carbondale, CO 81623
970-704-0484
cell) 970-309-5259 office)
carla.ostberg(a gmail.com
March 24, 2017
Steve Brammell
sbrammell(awa000.com
Onsite Wastewater Treatment System (OWTS) Use Permit Inspection
1000 Lazy O Read
Pitkin County, Colorado
Steve,
As requested, �BO Inc. performed an Onsite Wastewater Treatment System (OWTS) Use Permit
inspection at 1000 Lazy O Road, Snowmass, Colorado on March 20, 2017. The legal description of the
7.83 -acre property is Lot 7, Lazy O Ranch Subdivision.
The permit andidrawing of the proposed system' was provided by Pitkin County Environmental Health
Department (Parcel ID #2645-034-01-007). The subject OWTS consists of one 2500-gallon2 concrete
septic tank followed by 1000 -gallon concrete septic tank that serves as a re -circulating tank with the
recirculating splitter valve (RSV) and recirculating pump. Effluent gravity flows to pump vault located
downhill and west of the residence, east of Lazy O Road. The Geoflow@ headworks is located near the
pump vault. Effluent is pumped to an automatic distributing valve (ADV) located just south of the
driveway. The Geoflow® drip line or soil treatment area (STA) is located in the open field south of the
driveway and east of Lazy O Road. The STA consists of six zones, each with 5 drip lines, 190 -feet long
for a total of 950 feet of drip line in each section. Individual Sewage Disposal System Permit 04072
documents thisi system. The system was sized to accommodate 5 bedrooms. The permit received
final approval on July 27, 2006.
This system has advanced treatment technology and requires routine maintenance. We understand
there is no pass or current maintenance contract on this system. A maintenance contract must be
secured for cgntinued operation and maintenance of this system. We recommend Valley Precast
out of Buena Vista for this work.
A clean out is located to the north of the residence. A manhole access, which has 10 -feet of risers,
provides access to where the sewer line from the main house and sewer line from the caretaker dwelling
unit (CDU) come together. This manhole access appears to have an accumulation of some debris, but
flow through the access appeared normal. The septic tanks and two AdvanTex® AX 20 pods are located
west of the residence, just below the driveway. We believe the first septic tank in the series is 3000 -
gallons. This septic tank has both inlet and outlet tees. The septic tank was pumped by Altitude Septic
at the time of toe inspection. There was a significant amount of debris flowing over the inlet tee prior to
pumping.
Half of the volume of the septic tank housing the RSV and recirculating pump was pumped at the time of
the inspection. The pump truck was full and can return for completion of pumping, if necessary. We did
leave some effluent in the septic tank in order to run the pumping system safely during maintenance.
The effluent filter was extremely clogged and was cleaned at the time of pumping. The RSV was also
' Note that we did not receive a "record drawing" for reference. All notes on the drawing indicate "proposed"
components.
2 Pumping indicates this septic tank is more likely 3000 -gallons.
dirty and was cleaned at the time of the inspection. We opened the valves on the laterals in the AX pods
to flush them and black sludge came out of the laterals. The last lateral in both pods did not have flow
and we believe these laterals are blocked. Additional flushing will be necessary to properly clean the
laterals and pods.
We observed the discharge pump, which is located down the hill below the Geoflow(@ system. The filter
appears to be clogged and in need of cleaning. We did not have water available at that location to clean
the filter. The headworks for the Geoflow® system is located near the discharge pump tank. There
appears to be bjroken piping in the headworks that will require repair work.
The control panI is located on the north side of the residence.
We observed the ADV which is located south of the driveway, uphill of the STA. It is accessible in a riser.
The STA was observed and it appears there are air release valves at the end of each Geoflow® drip line
section which are accessible from grade. We walked the STA and did not observe any evidence of
surface saturation or failure at the time of our inspection.
Repairs and continued routine maintenance is necessary prior to obtaining the required OWTS Use
Permit for thisWTS.
Required Repa rs:
• Hinges and supports on the second AX 20 pod must be repaired.
• Handle extensions must be installed on the effluent filter and float tree in the recirculating tank.
• The lid on the manway covering the headworks is very deteriorated (too deteriorated to put back
on) and must be replaced.
• The discharge pump tank should be pumped (with access from Lazy O Road) and the discharge
filter must be cleaned.
• Handle extensions must be installed on the effluent filter and float tree in the discharge tank.
• The AdvanTex® system and Geoflow® system must be flushed by a qualified maintenance
provider.
• A contract must be secured by a qualified maintenance provider to assure proper long-term
maintenance.
This report, documentation of repairs and routine maintenance by a qualified maintenance
provider, and a completed OWTS Use Permit Application must be submitted to the Pitkin County
Environmental Health Department. Applications may be submitted to Pitkin County Environmental Health
Department electronically. The following are links to the required OWTS Use Permit Application and
Checklist.
Application: http://www.pitkincounty.com/DocumentCenter/Home/View/621
Application Checklist: http://www.pitkincountV.com/DocumentCenter/HomeNiew/620
All questions rearding permit submission can be directed to Pitkin County Environmental Health
Department, 97p-920-5070.
Disclaimer: -this inspection is intended only as an evaluation of the present condition of the OWTS
based upon what was observed and the Licensed Inspector's expertise in onsite wastewater technology.
The Inspector has not been retained to warrant or guarantee the proper functioning of the system for any
period of time in the future. Because of numerous factors which may affect the operation of an OWTS,
as well as the inability of the Inspector to supervise or monitor the use or maintenance of this OWTS, this
report shall not be construed as a warranty by the Inspector that the system will function properly for any
particular prospective buyer, and the Inspector disclaims any warranty, either expressed or implied,
arising from the inspection of the OWTS or this report. The evaluation does not ascertain the impact the
system is having on groundwater.
Please call with questions.
Sincerely,
Carla Ostberg, MPH, REHS
NAWT Certified Inspector
Certification # 110441TC Exp. April 2018
Clean out and -foot manhole access where the sewer lines from the main house and CDU come
together.
Inlet tee (clogged)
Outlet tee of first septic tank Pump truck
Control panel
Inside door
Pump controls
zl--
Pods
Glue detached stryofoam
Recirc tank
Clogged filter
Float tree and filter
RSV (needed cleaning)
Flushing into
•'_tie:,_
very dirty from pods
Inlet tee of recirrc tank
Recirc filter cleaned at time of inspection
we
pipe
Discharge tank
dworks
filter needs to be cleaned and handle extensions added
Air relief valves
STA
%,i, IN Onsite Wastewater Treatment Systems (OWTS) Use
Permit Inspection Form
-,FkC01 JNT Pitkin County Environmental Health Department
76 Service Center Rd, Aspen, CO 81611
Phone: 970-920-5070 Fax: 970-920-5374
Website: I http://pitkincounty.com/248[Wastewater-Treatment
Inspection form for continued use of an existing OWTS
Owner's Name:
Address:
Parcel Number:
Inspection) Date:
Inspector's Name:
Business Name:
Phone Number
Email:
Steve Brammell
1000 Lazy O Road
Snowmass CO
2645 034 01 007
3/20/17
Carla Ostber
CBO Inc.
970 309-5259
carla.ostberg@gmail.com
Pitkin County Systems Inspector License Number: 1017
A copy of this i section report will be remitted to Pitkin CountV Environmental Health Department b
the Licensed ystems Inspector within 60 days of the inspection regardless of whether the system
passes or fails.
QUESTIONS FOR PROPERTY OWNER PRIOR TO INSPECTION:
Is the home currently occupied? ❑' YES [:]NO
If NO, how long lhas the home been vacant?
How many bedrooms are in the home? 5 3 bedrooms main
If secondary treatment is used, who is the use + 2 bedrooms
maintenance provider? no maintenance provider CDU
RECORDS:
Were system records available from Pitkin County? ®' YES ®NO
If YES: Permit number: I ISDS Permit 04072
Date of Final Approval: IJuIv 27, 2006
# of bedrooms permitted: 0
lanas-builtdrawingavailable? FIYES NO drawing with proposed
Is the as -built drawing accurate? YES NO component locations
If NO: Complete a drawing of the system on last page of this form as accurately as
possible.
Any question marked FAIL will require correction before an OMITS Use permit is issued.
SITE CONDITIONS:
Proper grading,'Ino evidence of erosion? PASS FAIL
Improper vegetative cover? ' NO YES
Evidence of compaction such as heavy machinery or livestock? ' NO YES
Improper discharges such as straight pipes? PASS ❑FAIL
Evidence of high ground water? Q NO M YES
Snow cover present? M NO M YES
Page 1 Effective Date 1/12/2017
TANK:
IFIPASSFAIL
primary tank
Tank 1
recirc t
Tank 2
Idischarge tank
Tank 3
Tank capacity
Evidence of past surfacing?
3,000 gallons 1,000 gallons
gallons
Tank material
0 YES
concrete
concrete
concrete
Field location verified by observation ports or probing:
# of compartments
Probing
2
2
YES
If YES, record depth:
Date of last purnping
inches
2014
2014
unknown
If YES, is it accessible from grade?
Lids/risers in good
condition
Pass
Pass
Pass
Risers to grade
Yes
Yes
No
Riser height
3'
3'
3'
Riser condition/watertightness
yes
yes
yes
Inlet sanitary T/baffle
Pass
jPass
Select One
Outlet sanitary h /baffle
Pass
Select One
Select One
Effluent filter (it part of design)
N/A
Pass
Pass
Condition of tank material
Pass
Pass
Pass
Tank was pumped for inspection
Yes
Yes
No
If YES, list the pumping company
Altitude Septic
If NO, when was the last pumping
Scum level (1st compartment)
inches
inches
inches
Sludge level (1st: compartment)
inches
inches
inches
Scum level (2nd compartment)
inches
inches
inches
Sludge level (2nd compartment)
inches
inches
inches
Backflow (if pumped)
Pass
Pass
Select One
Midtank baffle
Select One
Select One IlSelect
One
Watertiehtness
1Pass
Pass
Pass
PUMPS/DOSING SIPHONS:
Is a pump or dosing siphon present? YES NO
If YES, is the pump/dosing siphon functioning properly? RASS FAIL
Does the pump/wiring/dosing siphon appear to be in good condition? r7 -PASS ❑FAIL
Is the high water alarm working, both visible and audible? ❑PASS ❑FAIL
SECONDARY TREATMENT:
Is a secondary treatment unit present? [EYES M NO ❑UNKNOWN
If YES, does the unit appear to be in good working condition? YES NO
Does the owner! have a current maintenance contract for the unit? RYES eNO —]UNKNOWN
Maintenance Priovider: no maintenance provider Phone:
If there is noaintenance contract, a contract must be in place prior to occupancy of the home. A
col oft a contract must be submitted to Pitkin County Environmental Health Department.
ABSORBTION AREA:
IFIPASSFAIL
Effluent surfacing?
HYES
Evidence of past surfacing?
IF] NO
Surface dampness?
NO
0 YES
Excessive odorsl
NO
YES
Field location verified by observation ports or probing:
■ Ports
Probing
Liquid in observation port?
■ NO
YES
If YES, record depth:
inches
Distribution Box or ADV part of original design?
NO
If YES, is it accessible from grade?
"PASS
NO
Is it level and in good condition?
FAIL
lair releif valves
UNKNOWN
only 1 lid
accessible
on
discharge
tank
Page 2 Effective Date 1/12/2017
3lease list any recommendations for the continued use of the system:
secure maintenance contract with qualified maintenance provider
Were any repairs done as a result of this inspection? ONO M YES
Documentation of all repair and maintenance work must be submitted from a qualified
maintenance provider prior to obtaining the required OWTS Use Permit.
To the best of my knowledge and training, the information collected in this inspection is accurate as of
March 24 1, 20 17
Digitally nAgLicensed Systems Inspector Signature: arlaOstber9 Dale; 2017.03.2413.59.31460
Clearly label any pictures and attach them to this form.
Save Forme Clear Form' Print Form
Page 3 Effective Date 1/1212017
3/24/2017
V�
Re: 1000 Lazy O Road OWTS Inspection
1 message
Gmail - Re: 1000 Lazy O Road OWTS Inspection
Carla Ostberg <carla.ostberg@gmail.com>
Terry Rogers<terry. rogers @s othebys realty. com > n, mar Z4,
To: Carla Ostberg <carla.ostberg@gmail.com>
Cc: Steve Brammell <sbrammell@yahoo.com>, Ted Borchelt <Ted.Borchelt@sothebys realty. com>, Jana Dillard <Jana.Dillard@sothebysrealty. com>
There are actually five bedrooms: three in main house and two in the guest house.
Terry Rogers
Aspen Snowmass Sotheby's International Realty
50 Snowmass Village Mall, PO Box 5000
Snowmass Village, CO 81615
Cell: 970-379-2443
Office: 800-898-4535
Fax: 970-923-2550
Terry.Rogers@SIR.com
Trogers@clre.com
A sp en Sn o wm ass SIR, com
AspenSnowmassDreamHomes.com
From: Carla Ostberg <carla.ostberg@gmail.com>
Date: Friday, March 24, 2017 at 5:36 PM
To: Terry Rogers <terry.rogers@sothebysrealty.com>
Cc: Steve Brammell <sbrammell@yahoo.com>, Ted Borchelt <Ted. Borchelt@sothebysrealty. corn>, Jana Dillard
<Jana.DiIla rd@sothebysrealty.corn>
Subject: Re: 1000 Lazy O Road OWTS Inspection
Hi Terry,
Yes, there is an additional visit for repairs and the rest of the routine maintenance that should performed. I have contacted Valley Precast and they will get me a
quote which I will forward to you before we schedule anything. They are the most qualified company to perform the repairs and routine maintenance, and they will
hftps://m ai l.google.com/mai I/u/0/?ui=2&i k=fee4fb5Oa9&view=pt&search= inbox&th=15b02b8e44a9ce4e&si m 1= 15b02b8e44a9ce4e 1/4
P.O.V
VALLEY
PRECAST, nc. (719) Box
ox 9 9252s
Buena Vista, CO 81211
ADVANTEX OPERATION AND MAINTENANCE RENEWAL CONTRACT
Street Address 1000 Lazy O
VPI Inc. will performoperation and maintenance services for the Onsite Wastewater System serving the subject site as outlined
below: r
Control Panel, Pumpand Alarms: During each visit, all electrical components shall be tested for proper function. Correct
control settings will be verified. Operations data from panel will be recorded.
Processing Tank: D ing each visit, the scum and sludge layers in the processing tank (septic tank) will be measured. A
recommendation for pumping will be made when the scum thickness exceeds four inches, or the sludge thickness exceeds 24
inches.
Pumping Sys
manually. Th
Recirculatin€
be cleaned as
be flushed.
Drain Field:
effluent pondi
each visit all pumps shall be observed to verify proper performance. The pumps will be operated
een will be removed and cleaned if needed.
filter will be observed for signs of excess organic build-up or improper performance. The media will
he system will be observed to verify proper distribution across the media and distribution laterals will
irea around the drain field will be observed for signs of failure such as lush vegetation growth or
:eels within the field will be observed if pump discharge water is obstructed.
Items that are not inclu ed in this contract include:
1. Corrective and/or repair maintenance if necessary, other than covered under warranty.
2. Effluent samp ing and analysis if applicable.
3. The cost of tank pumping.
Alarms: Alarms will Oe responded to via VeriComm remotely at no charge. If an onsite visit is needed VPI will respond twice at
no charge before servio call pricing begins. *Any materials not under warranty will be billed to owner.
Service Calls: Servicc calls will be billed at a rate of $80.00 per hour and $50.00 per hour for travel time. A visit to the site other
than the routine visits I rovided by this agreement or a system warranty issue will be deemed a service call. Examples would
include (but are not firr. 'ted to) damage caused by acts of vandalism, failure of tank or failure of another party's work, i.e.
electrician, plumber, excavator, etc. If a safety concern is present owner will be contacted immediately to resolve issue.
The goal of VPI is too serve the operation and perform maintenance for the Onsite Wastewater System to allow for proper long-
term function of the sy tem and compliance with the conditions of the installation permit and recommendations of the
manufacturer.
VPI will perform O& services as outlined for $285 per visit, with two visits per year ($570 per year). Payment in full for the
(1, 2, 3, 4, 5) years is r -,quired prior to initiation of the agreement. This agreement period will be for the (1, 2, 3, 4, 5) year period
subsequent to placing t ie system into operation. If you renew for 5 years, you will receive a 10% discount.
Property Owner (Please Print Name and Mailing Address)
Property Owner
Jerry L. Fleck
VPI Representative
Date
Telephone Number
Date
C:\Users\Carla\Documents\Documents\Use Inspections\1000 Lazy O\Application\ADV O&M
Agreement.doc
Valley Precast, Inc.
P.O. Box 925
Buena Vista, CO 81211
Phone: 719-395-6764
Fax: 719-395-3727
E -Mail: frontdesk@valleyprecast.com
Website: valleyprecast.com
Bill To
CBO Inc.
33 Four Wheel Drive Road
Carbondale, CO 81623
Invoice
Date Invoice #
4/7/2017 34532
Item
Location
Terms
Due Date
1000 Lazy O
Due on receipt
4/7/2017
Item
Description
Quantity
Amount
Total
Miscellaneous
Hinges, pipe fittings, extensions and T's for handles, styrofoam
1
75.00
75.00T
attachment
Flat Lid 34" X 3"
Flat Lid 34" X 3" (replacement for Headworks box
1
36.05
36.05T
Service Tech
Reattach pod lid to hinges, Extended float tree and filter
3
100.00
300.00
handles, flushed Geo flow System through headworks, effluent
filter handles, clean discharge filter.
Service Travel
Travel time for service call
2
51.50
103.00
Thank you!
A 1.5% per month finance charge will be assessed on accounts over 30 days (Minimum of
$5.00 per month). If an account is delinquent for 60 days, Credit Will Be Withdrawn. Any
further orders will be Cash, Only.
By accepting our product(s), you are agreeing to pay the full amount owed as well as any
legal fees and finances charges that may be assessed.
Signature
Sales Tax (2.9%) $3.22
Total $517.27
County
60 days