HomeMy WebLinkAboutpitkin.eh.264503401007 (2017)�PTx[N COUNT' Pitkin County Environmental Health Department Onsite Wastewater Treatment System (OWTS) USE PERMIT Permit for Continued Use of an Existing OWTS 76 Service Center Road, Aspen, CO 81611 Phone: 970-920-5070 Fax: 970-920-5077 www.aspenpitkin.com/EHNR Parcel ID #: 1 2645-034-01-007 OWTS Use Permit #: I 0029.2017.POWU Date Issued: 4/25/2017 Issued By: Bryap Daugherty Expiration Date: 4/25 18 Owner(s): I Steve Brammell Trust Property Address: 1000 Lazy O Road Legal Description: Lot 7, Lazy O Ranch Licensed Inspector: C rla Ostberg Inspection Date(s): 31(20/17 SYSTEM INFORMATION Components Type Capacity/Size Primary Treatment Unit Concrete single compartment tank Concrete single compartment tank 2500 gallons 1000 gallons Secondary Treatment Unit Advantex AX -20 Absorption Area Geoflow Driplines 6 zones (11,375 ft2 total) Other System Components Pump ®In use at the time of the inspection. ❑Not in use at the time of the inspection.* *If the OWTS was not in use t the time of the inspection, it is recommended that the system be re-evaluated when it is in use for a more accurate evaluation of the system. System Records: Permit #: 04072 (Date of Issuance: 10/15/04 Date of Final Approval: 7/27/06 # of Bedrooms or fixtures served by OWTS: System is designed to serve 5 bedrooms Operational Status: According to the observations of the inspector the system was functioning as designed. The advanced treatment system did not have a maintenance agreement at the time of inspection but is now in place. The field area did not show any signs of failure. Repairs were made to the Advantex Pod lid, and the effluent filter. Inspector Recommendations: N/A Department Recommendations: Annual maintenance Issuance of this OWTS Use Permit is based solely on the conditions observed and reported by the inspector to the Department on the date of the inspection(s) and on Department records at the tilne of permitting. The issuance of this permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail or that the system will not be subject to future enforcement action to correct non-compliant conditions. Estimated capacity of the system has been listed on the permit and we recommend that you monitor and/or meter water use to prevent overuse and possible failure. Pitkin County Environmental Health Department Permit for an Individual Sewage Disposal System 0405 Castle Creek Road, Suite 10, Aspen, Colorado 81611 Phone 970-920-5070 / FAX 970-920-5077 Permit # 6`i6� Parcel ID # 2645-034-01-007 Type of permit New(X ) Repair( ) Addition/Remodel to House( } Name of Owner Steven & Alison Brammell Street Address 1000 Lazy O Road, Snowmass, CO 81621 Property legal description Lazy O Subdivision Size of lot 7.83 acres Total square footage of the house 8,400 Water source Community/Public Water Svstem # of bedrooms in house 3 # of offices, lofts & similar sized rooms in house Caretaker unit Total square footage of the caretaker unit # of bedrooms in caretaker unit 2 # of offices, lofts & similar sized rooms in caretaker unit Designed for what # roo.. s (list) 5 total .= 3 house+2 future caretaker (2'people/BR, no room used as a bunkroom) Permit information Designed by Gamba & Associates Mailing Address 113 9"' St, Suite 214, Glenwood Springs, CO 81602-1458 Perc rate (80). Profile hole depth 9 ft Depth to groundwater or bedrock > 9 ft Minimum Septic tank capacity 2,844 gallons Minimum Absorption area * see engineer design Comments Septic permit approved' per compliance with the engineer design and specifications stamped and revised 09196104. Any changes must be approved by this department and the design engineerrp for to them being made. Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin County ISDS regulations. 'Because of the slow percolating soils, the design is for a drip dispersal system based on an LTAR rate of 0.2. There is one 2,500 gallon tank followed by a 1,000 gallon tank with two Advantex AX -20 filter modules. Both tanks are single compartment, concrete tanks. The field is six zones of Geoflow driplines for a total of 5,700 lineal ft, for an effective area of 11,875 sq ft. There is a two foot separation between each dripline. Driplines are kept shallow, but must be a minimums of 12 inches below the surface of the ground. This department does riot endorse any brand of products. This permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an as -built letter to this department. This department must also be called for an inspection with a minimum of 48 hours advanced notice. 'Revegetation over the area of the field is very important for the functioning of the system. Pitkin County has guidelines that must be followed to assure the plants that are introduced are appropriate for the conditions of the area. The use of native plants is strongly encouraged. Permit approved by: Date: Plans and specifications of the oposed individual sewage disposal system have been reviewed and are considered satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was issued unless system construction has commenced or an extension has been approved in writing by the Department. As -built drawings �m.y}�+st be included with t s permit before the final approval will be issued. Installer:i.��ticcc�a;` > a'h a :a T. + . . ..........:: Pitkin County Environmental Health Department TIK 1111 Onsite Wastewater Treatment System (OWTS) CO U ill TV USE PERMIT APPLICATION 76 Service Center Rd 4 - Aspen, CO 81611 http://pitkincounty.com/248/\Nastewater-Treatment Application for Continued Use of an Existing OWTS 0 Parcel I D# (available from the Pitkin County Assessor's Office 2645 034 01 007 970-920-5160 or at http:ilpitkinassessor.org/assessor/search.asp Aspen Snowmass Sotheby's Purpose of Use Permit: PROPERTY TRANSACTION ®REMODEL/ Property Address: sbrammell@yahoo.com Owner's Mailing Address: 1000 hazy O Road Cell Phone: Lot: Block: Filing: Snowmass Subdivision: 81654 Home Phone: 7 Business Phone: [Lazy O Ranch PUD Residences: Other # of Bedrooms: 5 fixtures/uses: Property Owners)*: Terry Rogers Email Address: Aspen Snowmass Sotheby's Contact/Applicant Mailing Address: Stev Brammell Trust sbrammell@yahoo.com Owner's Mailing Address: City, State, Zip: Cell Phone: (970) 379-2443 Business Phone: 000 Lazy O Road Snowmass CO 81654 Home Phone: Indicate Preferred Method of Payment Business Phone: contact information must pe provided for the owner signing this application. Primary Contact Person/Applicant (if not owner): Terry Rogers Company: Aspen Snowmass Sotheby's Contact/Applicant Mailing Address: City, State, Zip: Cell Phone: (970) 379-2443 Business Phone: Fax Number: Email Address: carla.ostberg@gmail.com Indicate Preferred Method of Payment Check • Credit/Debit U Cash Licensed Systems Inspector: Phone Number: Email Address: Fax Number: Carla Ostberg (970) 903-5259 carla.ostberg@gmail.com Mailing Address: CitV, State Zip: 33 Four Wheel Drive Road Icarbondale 100 181623 PLEASE READ BEFO. _1GNING: certify that the above information is complete and accurate and that I have provided complete and accurate information in all of the documents ncluded in my application package. I acknowledge that this department may revoke any permit I am issued if my application is found to contain any naccurate, false, or misleading information. Owner Signature (Required): Date: Stephen Brammell 3/25/17 Applicant Signature:�arla OStberg 3�4'�� Y 4`:r� ty C::� � G c••a Date: 17at`.t 17si3.2•. 14 24.36 Please allow 3-5 business days for processing of Use Permits. Save Form Clear Form Print Form FOR OFFICE USE ONLY Received by EH Staff: Fee & Receipt #: Date: Effective ants IAW2017 March 24, 2017 Steve Brammell sbrammell(awa000.com Onsite Wastewater Treatment System (OWTS) Use Permit Inspection 1000 Lazy O Read Pitkin County, Colorado Steve, As requested, �BO Inc. performed an Onsite Wastewater Treatment System (OWTS) Use Permit inspection at 1000 Lazy O Road, Snowmass, Colorado on March 20, 2017. The legal description of the 7.83 -acre property is Lot 7, Lazy O Ranch Subdivision. The permit andidrawing of the proposed system' was provided by Pitkin County Environmental Health Department (Parcel ID #2645-034-01-007). The subject OWTS consists of one 2500-gallon2 concrete septic tank followed by 1000 -gallon concrete septic tank that serves as a re -circulating tank with the recirculating splitter valve (RSV) and recirculating pump. Effluent gravity flows to pump vault located downhill and west of the residence, east of Lazy O Road. The Geoflow@ headworks is located near the pump vault. Effluent is pumped to an automatic distributing valve (ADV) located just south of the driveway. The Geoflow® drip line or soil treatment area (STA) is located in the open field south of the driveway and east of Lazy O Road. The STA consists of six zones, each with 5 drip lines, 190 -feet long for a total of 950 feet of drip line in each section. Individual Sewage Disposal System Permit 04072 documents thisi system. The system was sized to accommodate 5 bedrooms. The permit received final approval on July 27, 2006. This system has advanced treatment technology and requires routine maintenance. We understand there is no pass or current maintenance contract on this system. A maintenance contract must be secured for cgntinued operation and maintenance of this system. We recommend Valley Precast out of Buena Vista for this work. A clean out is located to the north of the residence. A manhole access, which has 10 -feet of risers, provides access to where the sewer line from the main house and sewer line from the caretaker dwelling unit (CDU) come together. This manhole access appears to have an accumulation of some debris, but flow through the access appeared normal. The septic tanks and two AdvanTex® AX 20 pods are located west of the residence, just below the driveway. We believe the first septic tank in the series is 3000 - gallons. This septic tank has both inlet and outlet tees. The septic tank was pumped by Altitude Septic at the time of toe inspection. There was a significant amount of debris flowing over the inlet tee prior to pumping. Half of the volume of the septic tank housing the RSV and recirculating pump was pumped at the time of the inspection. The pump truck was full and can return for completion of pumping, if necessary. We did leave some effluent in the septic tank in order to run the pumping system safely during maintenance. The effluent filter was extremely clogged and was cleaned at the time of pumping. The RSV was also ' Note that we did not receive a "record drawing" for reference. All notes on the drawing indicate "proposed" components. 2 Pumping indicates this septic tank is more likely 3000 -gallons. CBO Inc. 33 Four Wheel Drive Road Carbondale, CO 81623 970-704-0484 cell) 970-309-5259 office) carla.ostberg(a gmail.com March 24, 2017 Steve Brammell sbrammell(awa000.com Onsite Wastewater Treatment System (OWTS) Use Permit Inspection 1000 Lazy O Read Pitkin County, Colorado Steve, As requested, �BO Inc. performed an Onsite Wastewater Treatment System (OWTS) Use Permit inspection at 1000 Lazy O Road, Snowmass, Colorado on March 20, 2017. The legal description of the 7.83 -acre property is Lot 7, Lazy O Ranch Subdivision. The permit andidrawing of the proposed system' was provided by Pitkin County Environmental Health Department (Parcel ID #2645-034-01-007). The subject OWTS consists of one 2500-gallon2 concrete septic tank followed by 1000 -gallon concrete septic tank that serves as a re -circulating tank with the recirculating splitter valve (RSV) and recirculating pump. Effluent gravity flows to pump vault located downhill and west of the residence, east of Lazy O Road. The Geoflow@ headworks is located near the pump vault. Effluent is pumped to an automatic distributing valve (ADV) located just south of the driveway. The Geoflow® drip line or soil treatment area (STA) is located in the open field south of the driveway and east of Lazy O Road. The STA consists of six zones, each with 5 drip lines, 190 -feet long for a total of 950 feet of drip line in each section. Individual Sewage Disposal System Permit 04072 documents thisi system. The system was sized to accommodate 5 bedrooms. The permit received final approval on July 27, 2006. This system has advanced treatment technology and requires routine maintenance. We understand there is no pass or current maintenance contract on this system. A maintenance contract must be secured for cgntinued operation and maintenance of this system. We recommend Valley Precast out of Buena Vista for this work. A clean out is located to the north of the residence. A manhole access, which has 10 -feet of risers, provides access to where the sewer line from the main house and sewer line from the caretaker dwelling unit (CDU) come together. This manhole access appears to have an accumulation of some debris, but flow through the access appeared normal. The septic tanks and two AdvanTex® AX 20 pods are located west of the residence, just below the driveway. We believe the first septic tank in the series is 3000 - gallons. This septic tank has both inlet and outlet tees. The septic tank was pumped by Altitude Septic at the time of toe inspection. There was a significant amount of debris flowing over the inlet tee prior to pumping. Half of the volume of the septic tank housing the RSV and recirculating pump was pumped at the time of the inspection. The pump truck was full and can return for completion of pumping, if necessary. We did leave some effluent in the septic tank in order to run the pumping system safely during maintenance. The effluent filter was extremely clogged and was cleaned at the time of pumping. The RSV was also ' Note that we did not receive a "record drawing" for reference. All notes on the drawing indicate "proposed" components. 2 Pumping indicates this septic tank is more likely 3000 -gallons. dirty and was cleaned at the time of the inspection. We opened the valves on the laterals in the AX pods to flush them and black sludge came out of the laterals. The last lateral in both pods did not have flow and we believe these laterals are blocked. Additional flushing will be necessary to properly clean the laterals and pods. We observed the discharge pump, which is located down the hill below the Geoflow(@ system. The filter appears to be clogged and in need of cleaning. We did not have water available at that location to clean the filter. The headworks for the Geoflow® system is located near the discharge pump tank. There appears to be bjroken piping in the headworks that will require repair work. The control panI is located on the north side of the residence. We observed the ADV which is located south of the driveway, uphill of the STA. It is accessible in a riser. The STA was observed and it appears there are air release valves at the end of each Geoflow® drip line section which are accessible from grade. We walked the STA and did not observe any evidence of surface saturation or failure at the time of our inspection. Repairs and continued routine maintenance is necessary prior to obtaining the required OWTS Use Permit for thisWTS. Required Repa rs: • Hinges and supports on the second AX 20 pod must be repaired. • Handle extensions must be installed on the effluent filter and float tree in the recirculating tank. • The lid on the manway covering the headworks is very deteriorated (too deteriorated to put back on) and must be replaced. • The discharge pump tank should be pumped (with access from Lazy O Road) and the discharge filter must be cleaned. • Handle extensions must be installed on the effluent filter and float tree in the discharge tank. • The AdvanTex® system and Geoflow® system must be flushed by a qualified maintenance provider. • A contract must be secured by a qualified maintenance provider to assure proper long-term maintenance. This report, documentation of repairs and routine maintenance by a qualified maintenance provider, and a completed OWTS Use Permit Application must be submitted to the Pitkin County Environmental Health Department. Applications may be submitted to Pitkin County Environmental Health Department electronically. The following are links to the required OWTS Use Permit Application and Checklist. Application: http://www.pitkincounty.com/DocumentCenter/Home/View/621 Application Checklist: http://www.pitkincountV.com/DocumentCenter/HomeNiew/620 All questions rearding permit submission can be directed to Pitkin County Environmental Health Department, 97p-920-5070. Disclaimer: -this inspection is intended only as an evaluation of the present condition of the OWTS based upon what was observed and the Licensed Inspector's expertise in onsite wastewater technology. The Inspector has not been retained to warrant or guarantee the proper functioning of the system for any period of time in the future. Because of numerous factors which may affect the operation of an OWTS, as well as the inability of the Inspector to supervise or monitor the use or maintenance of this OWTS, this report shall not be construed as a warranty by the Inspector that the system will function properly for any particular prospective buyer, and the Inspector disclaims any warranty, either expressed or implied, arising from the inspection of the OWTS or this report. The evaluation does not ascertain the impact the system is having on groundwater. Please call with questions. Sincerely, Carla Ostberg, MPH, REHS NAWT Certified Inspector Certification # 110441TC Exp. April 2018 Clean out and -foot manhole access where the sewer lines from the main house and CDU come together. Inlet tee (clogged) Outlet tee of first septic tank Pump truck Control panel Inside door Pump controls zl-- Pods Glue detached stryofoam Recirc tank Clogged filter Float tree and filter RSV (needed cleaning) Flushing into •'_tie:,_ very dirty from pods Inlet tee of recirrc tank Recirc filter cleaned at time of inspection we pipe Discharge tank dworks filter needs to be cleaned and handle extensions added Air relief valves STA %,i, IN Onsite Wastewater Treatment Systems (OWTS) Use Permit Inspection Form -,FkC01 JNT Pitkin County Environmental Health Department 76 Service Center Rd, Aspen, CO 81611 Phone: 970-920-5070 Fax: 970-920-5374 Website: I http://pitkincounty.com/248[Wastewater-Treatment Inspection form for continued use of an existing OWTS Owner's Name: Address: Parcel Number: Inspection) Date: Inspector's Name: Business Name: Phone Number Email: Steve Brammell 1000 Lazy O Road Snowmass CO 2645 034 01 007 3/20/17 Carla Ostber CBO Inc. 970 309-5259 carla.ostberg@gmail.com Pitkin County Systems Inspector License Number: 1017 A copy of this i section report will be remitted to Pitkin CountV Environmental Health Department b the Licensed ystems Inspector within 60 days of the inspection regardless of whether the system passes or fails. QUESTIONS FOR PROPERTY OWNER PRIOR TO INSPECTION: Is the home currently occupied? ❑' YES [:]NO If NO, how long lhas the home been vacant? How many bedrooms are in the home? 5 3 bedrooms main If secondary treatment is used, who is the use + 2 bedrooms maintenance provider? no maintenance provider CDU RECORDS: Were system records available from Pitkin County? ®' YES ®NO If YES: Permit number: I ISDS Permit 04072 Date of Final Approval: IJuIv 27, 2006 # of bedrooms permitted: 0 lanas-builtdrawingavailable? FIYES NO drawing with proposed Is the as -built drawing accurate? YES NO component locations If NO: Complete a drawing of the system on last page of this form as accurately as possible. Any question marked FAIL will require correction before an OMITS Use permit is issued. SITE CONDITIONS: Proper grading,'Ino evidence of erosion? PASS FAIL Improper vegetative cover? ' NO YES Evidence of compaction such as heavy machinery or livestock? ' NO YES Improper discharges such as straight pipes? PASS ❑FAIL Evidence of high ground water? Q NO M YES Snow cover present? M NO M YES Page 1 Effective Date 1/12/2017 TANK: IFIPASSFAIL primary tank Tank 1 recirc t Tank 2 Idischarge tank Tank 3 Tank capacity Evidence of past surfacing? 3,000 gallons 1,000 gallons gallons Tank material 0 YES concrete concrete concrete Field location verified by observation ports or probing: # of compartments Probing 2 2 YES If YES, record depth: Date of last purnping inches 2014 2014 unknown If YES, is it accessible from grade? Lids/risers in good condition Pass Pass Pass Risers to grade Yes Yes No Riser height 3' 3' 3' Riser condition/watertightness yes yes yes Inlet sanitary T/baffle Pass jPass Select One Outlet sanitary h /baffle Pass Select One Select One Effluent filter (it part of design) N/A Pass Pass Condition of tank material Pass Pass Pass Tank was pumped for inspection Yes Yes No If YES, list the pumping company Altitude Septic If NO, when was the last pumping Scum level (1st compartment) inches inches inches Sludge level (1st: compartment) inches inches inches Scum level (2nd compartment) inches inches inches Sludge level (2nd compartment) inches inches inches Backflow (if pumped) Pass Pass Select One Midtank baffle Select One Select One IlSelect One Watertiehtness 1Pass Pass Pass PUMPS/DOSING SIPHONS: Is a pump or dosing siphon present? YES NO If YES, is the pump/dosing siphon functioning properly? RASS FAIL Does the pump/wiring/dosing siphon appear to be in good condition? r7 -PASS ❑FAIL Is the high water alarm working, both visible and audible? ❑PASS ❑FAIL SECONDARY TREATMENT: Is a secondary treatment unit present? [EYES M NO ❑UNKNOWN If YES, does the unit appear to be in good working condition? YES NO Does the owner! have a current maintenance contract for the unit? RYES eNO —]UNKNOWN Maintenance Priovider: no maintenance provider Phone: If there is noaintenance contract, a contract must be in place prior to occupancy of the home. A col oft a contract must be submitted to Pitkin County Environmental Health Department. ABSORBTION AREA: IFIPASSFAIL Effluent surfacing? HYES Evidence of past surfacing? IF] NO Surface dampness? NO 0 YES Excessive odorsl NO YES Field location verified by observation ports or probing: ■ Ports Probing Liquid in observation port? ■ NO YES If YES, record depth: inches Distribution Box or ADV part of original design? NO If YES, is it accessible from grade? "PASS NO Is it level and in good condition? FAIL lair releif valves UNKNOWN only 1 lid accessible on discharge tank Page 2 Effective Date 1/12/2017 3lease list any recommendations for the continued use of the system: secure maintenance contract with qualified maintenance provider Were any repairs done as a result of this inspection? ONO M YES Documentation of all repair and maintenance work must be submitted from a qualified maintenance provider prior to obtaining the required OWTS Use Permit. To the best of my knowledge and training, the information collected in this inspection is accurate as of March 24 1, 20 17 Digitally nAgLicensed Systems Inspector Signature: arlaOstber9 Dale; 2017.03.2413.59.31460 Clearly label any pictures and attach them to this form. Save Forme Clear Form' Print Form Page 3 Effective Date 1/1212017 3/24/2017 V� Re: 1000 Lazy O Road OWTS Inspection 1 message Gmail - Re: 1000 Lazy O Road OWTS Inspection Carla Ostberg <carla.ostberg@gmail.com> Terry Rogers<terry. rogers @s othebys realty. com > n, mar Z4, To: Carla Ostberg <carla.ostberg@gmail.com> Cc: Steve Brammell <sbrammell@yahoo.com>, Ted Borchelt <Ted.Borchelt@sothebys realty. com>, Jana Dillard <Jana.Dillard@sothebysrealty. com> There are actually five bedrooms: three in main house and two in the guest house. Terry Rogers Aspen Snowmass Sotheby's International Realty 50 Snowmass Village Mall, PO Box 5000 Snowmass Village, CO 81615 Cell: 970-379-2443 Office: 800-898-4535 Fax: 970-923-2550 Terry.Rogers@SIR.com Trogers@clre.com A sp en Sn o wm ass SIR, com AspenSnowmassDreamHomes.com From: Carla Ostberg <carla.ostberg@gmail.com> Date: Friday, March 24, 2017 at 5:36 PM To: Terry Rogers <terry.rogers@sothebysrealty.com> Cc: Steve Brammell <sbrammell@yahoo.com>, Ted Borchelt <Ted. Borchelt@sothebysrealty. corn>, Jana Dillard <Jana.DiIla rd@sothebysrealty.corn> Subject: Re: 1000 Lazy O Road OWTS Inspection Hi Terry, Yes, there is an additional visit for repairs and the rest of the routine maintenance that should performed. I have contacted Valley Precast and they will get me a quote which I will forward to you before we schedule anything. They are the most qualified company to perform the repairs and routine maintenance, and they will hftps://m ai l.google.com/mai I/u/0/?ui=2&i k=fee4fb5Oa9&view=pt&search= inbox&th=15b02b8e44a9ce4e&si m 1= 15b02b8e44a9ce4e 1/4 P.O.V VALLEY PRECAST, nc. (719) Box ox 9 9252s Buena Vista, CO 81211 ADVANTEX OPERATION AND MAINTENANCE RENEWAL CONTRACT Street Address 1000 Lazy O VPI Inc. will performoperation and maintenance services for the Onsite Wastewater System serving the subject site as outlined below: r Control Panel, Pumpand Alarms: During each visit, all electrical components shall be tested for proper function. Correct control settings will be verified. Operations data from panel will be recorded. Processing Tank: D ing each visit, the scum and sludge layers in the processing tank (septic tank) will be measured. A recommendation for pumping will be made when the scum thickness exceeds four inches, or the sludge thickness exceeds 24 inches. Pumping Sys manually. Th Recirculatin€ be cleaned as be flushed. Drain Field: effluent pondi each visit all pumps shall be observed to verify proper performance. The pumps will be operated een will be removed and cleaned if needed. filter will be observed for signs of excess organic build-up or improper performance. The media will he system will be observed to verify proper distribution across the media and distribution laterals will irea around the drain field will be observed for signs of failure such as lush vegetation growth or :eels within the field will be observed if pump discharge water is obstructed. Items that are not inclu ed in this contract include: 1. Corrective and/or repair maintenance if necessary, other than covered under warranty. 2. Effluent samp ing and analysis if applicable. 3. The cost of tank pumping. Alarms: Alarms will Oe responded to via VeriComm remotely at no charge. If an onsite visit is needed VPI will respond twice at no charge before servio call pricing begins. *Any materials not under warranty will be billed to owner. Service Calls: Servicc calls will be billed at a rate of $80.00 per hour and $50.00 per hour for travel time. A visit to the site other than the routine visits I rovided by this agreement or a system warranty issue will be deemed a service call. Examples would include (but are not firr. 'ted to) damage caused by acts of vandalism, failure of tank or failure of another party's work, i.e. electrician, plumber, excavator, etc. If a safety concern is present owner will be contacted immediately to resolve issue. The goal of VPI is too serve the operation and perform maintenance for the Onsite Wastewater System to allow for proper long- term function of the sy tem and compliance with the conditions of the installation permit and recommendations of the manufacturer. VPI will perform O& services as outlined for $285 per visit, with two visits per year ($570 per year). Payment in full for the (1, 2, 3, 4, 5) years is r -,quired prior to initiation of the agreement. This agreement period will be for the (1, 2, 3, 4, 5) year period subsequent to placing t ie system into operation. If you renew for 5 years, you will receive a 10% discount. Property Owner (Please Print Name and Mailing Address) Property Owner Jerry L. Fleck VPI Representative Date Telephone Number Date C:\Users\Carla\Documents\Documents\Use Inspections\1000 Lazy O\Application\ADV O&M Agreement.doc Valley Precast, Inc. P.O. Box 925 Buena Vista, CO 81211 Phone: 719-395-6764 Fax: 719-395-3727 E -Mail: frontdesk@valleyprecast.com Website: valleyprecast.com Bill To CBO Inc. 33 Four Wheel Drive Road Carbondale, CO 81623 Invoice Date Invoice # 4/7/2017 34532 Item Location Terms Due Date 1000 Lazy O Due on receipt 4/7/2017 Item Description Quantity Amount Total Miscellaneous Hinges, pipe fittings, extensions and T's for handles, styrofoam 1 75.00 75.00T attachment Flat Lid 34" X 3" Flat Lid 34" X 3" (replacement for Headworks box 1 36.05 36.05T Service Tech Reattach pod lid to hinges, Extended float tree and filter 3 100.00 300.00 handles, flushed Geo flow System through headworks, effluent filter handles, clean discharge filter. Service Travel Travel time for service call 2 51.50 103.00 Thank you! A 1.5% per month finance charge will be assessed on accounts over 30 days (Minimum of $5.00 per month). If an account is delinquent for 60 days, Credit Will Be Withdrawn. Any further orders will be Cash, Only. By accepting our product(s), you are agreeing to pay the full amount owed as well as any legal fees and finances charges that may be assessed. Signature Sales Tax (2.9%) $3.22 Total $517.27 County 60 days