Loading...
HomeMy WebLinkAboutpitkin.eh.264335108001 (2016)iTKIN COUNT NSITE WASTEWATER TREAT, --.:NT SYSTEM (OWTS) CONSTRUCTION PERMIT 76 Service Center Rd- Aspen, CO - 81611 Phone: 970.920.5070 Fax: 970.920.5374 Permit #: 0007.2016.pow2 Parcel ID #: 2643-351-08-001 Permit Issued: ®NEW CDU [-]REPAIR ❑REMODEL/ADDITION ❑TANK ONLY ❑FIELD ONLY ❑AMENDMENT Owner(s): 155 Danielson, LLC Property Address: 155 Danielson Dr Legal Description: R-72 Size of Lot: 2.11 Size of Building: 8613 ft2 Acres Detached Accessory Unit: ❑YES ®NO Sq. Ft. Size of Accessory This system is designed for 5 bedrooms in the main home and a 1 bedroom future CDU. TANK PERMIT WILL BE REQUIRED FOR FUTURE CDU ADDITION Designed By: All Service Septic Project #: _ Phone #: Mailing Address: Fax #: Email Address: LTAR: 0.6 Profile Hole Depth: 8 feet Minimum Tank Capacity: 2000 gallons Sq. Ft. C1030 Dated: October 21, 2014 Depth to Groundwater or Minimum Absorption 1208 ftz Permit Conditions: ➢ 8 feet This OWTS Construction Permit is approved on the condition of compliance with the engineer design as submitted with the application and the specifications cited above. Changes must be approved by this Department and the engineer prior to construction. This system is designed to serve both a 5 bedroom main home and future 1 bedroom CDU. The field area is designed with future CDU flows, a tank will be required for the CDU. Sewage will flow via gravity to a 1500 -gallon two-compartment concrete septic tank with and effluent filter installed in the second compartment. Effluent will then flow to a 1000 -gallon two- compartment concrete septic tank with a screened dosing siphon in the second compartment. Effluent will be dosed to a baffled distribution box and then to a seven trench soil treatment area with 15 Quick -4 chambers in each trench (90 chambers total). Each trench will have observation ports at both ends. The soil treatment area shall be a minimum of 100 feet to any well, 20 feet to the drinking water line and 10 feet to the property line. All tank risers and distribution box must be accessible from grade. This Permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an "as -built" letter to this Department within 30 days of the final inspection, unless a longer period of time has been agreed upon, in writing. This Department must also be called for the final inspection with a minimum of 48 hours notice. Minimum horizontal distances between components of the system and physical features shall conform to the requirements of the Pitkin County OWTS Regulation. This Permit is conditioned upon the property owner(s) providing for regular inspection, cleaning, and maintenance of the system by qualified personnel, in accordance with the manufacturer's recommendations and the requirements of the Pitkin County OWTS Regulation. Issuance of this OWTS Construction Permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail. Issuance of this permit does not imply compliance with Pitkin County building and/or land use regulations, nor guarantee issuance of building and/or land use permits. THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN COUNTY OWTS REGULATION, INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE. Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Pitkin County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built" drawing must be submitted and approved by EH before final approval of the system will be issued. Issued By: Kurt Dahl, REHS Date: 2/27/2015 Expires: 02/27/2016 Installgr. License #: Reactivation Authorized by: 'r4 .l.>&a/� .��Ci 4XJ K L µ� �l .i I� ❑FcePard l P] 000--1-2016. POw1 Z REQUEST FOR AN AMENDMENT TO AN MEHf OWTS CONSTRUCTION PERMIT 76 Service Center Rd • Aspen, CO •81611 Phone: 970.920.5070 Fax: 970.920.5374 This form should be used for requesting an amendment to on OWTS Construction Permit if there have been significant changes to an OWTS design that differ from what was approved as part of the OWTS Construction Permit. An hourly fee of $262/hour will be invoiced upon review of the new design and reissuance of the amended permit. The system requirements must conform to the current OWTS Regulation, which can be found at http•//www aspenpitkin com/P4 sIdepts112fowtsreq.pdf. Permit Number for Which Amendment is Requested tt 2Q 4_QV\') T Parcel 1D# (available from the Piddn County Assessor's Office 'ff 970-920-5160 or at www_pitkjnassessor.org): Z �j �i 091 Example: Property Address: 19D q L v-0 n Lot: —� 2 Block: Filing: l Subdivi "on:__ ' ( r � ^ t 1 Building Permit #: C7 k)--20tc-PVQVC. 'roperty Owner(s); Email Address: 155 bumf % � � Ti LLL )wner's Mailing Address: . e W 'C n City, State, Zip/1�Qri W It tome Phone: Business Phone: D J Primary Contact Person/Applicant (V not owner):. Company: e Yl Contact/Applicant Mailing Address: City, State, Zip: Cell Phone: 21 Business Phone: rFaxNumber: Email Address: r ss iii r. 'LEASE READ BEFORE SIGNING: certify that the above information is complete and accurate. 1 acknowledge that EH/NR may revoke any permit 1 am ssued if my application is found to contain any inaccurate, false, or misleading information, i understand that no :onstruction may be undertaken on the OWTS until the OWTS Construction Permit is amended or a new permit is issues j ry j Owner/Applicant Signature OFFICE USE ONLY: 911911 Date Recived by: Date: Invoice #: Invoice amount: Date received: e ALL33 Four Wheel Drive Rd CQrbondole, CO 81623 970-309-5259 June 17, 2017 Jeff and Rona Citrin 7 Dewart Road Greenwich, CT 06830 Onsite Wastewater Treatment System (OWTS) Installation Observations 155 Danielson Drive Pitkin County, Colorado OWTS Construction Permit Number 007.2016.POW2 Jeff and Rona, Project No. C1030 ALL SERVICE septic, LLC observed the installation of the onsite wastewater treatment system (OWTS) on June 6, 2015 and September 13, 2016 for the subject property. Excavation Services installed the system. The existing septic tank was removed and the existing soil treatment area (STA) was abandoned in place. The installation of the new OWTS included a 1500 -gallon, two-compartment concrete septic tank with an effluent filter, followed by a 1000 -gallon, two-compartment concrete septic tank with a screened dosing siphon in the second compartment. The dosing siphon was set to discharge approximately 100 gallons/dose. The siphon was tested at the time of our September 13, 2016 visit. Effluent is dosed to a baffled distribution box, accessible from grade, and then to seven gravelless chamber trenches, each with 15 'Quick 4' Infiltrator® chambers. There was a minimum of 6 -feet of undisturbed soil between each trench. Inspection ports were installed at the beginning and end of each trench. The OWTS was generally installed according to specifications. This observation is not a guarantee of workmanship and/or parts and materials. ALL SERVICE septic, LLC should be notified if changes are made to the OWTS in the future. Any additional OWTS construction must be according to the county regulations. LIMITS: Observations are limited to components that are visible at the time of the inspection. The installer must have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. The quality of the installation is dependent of the expertise of the installer, soil type, and weather conditions. Please call with questions. Sincerely, ALL SERVICE septic, LLC Carla Ostberg, MPH, REHS Reviewed Richard H 1500 -gallon tank followed by a 1000 -gallon tank with dosing siphon. Inlet pipe and clean out Sewer pipe exiting dosing tank Inlet tee Distribution box x: Effluent filter ..ter w Trenchpreparation r Chamber trenches with inspection ports Well -bedded pipes from d -box to trenches N ()'10' 20' Scale: V= 20'-0" 858k �;- . MEMORIES- --�/ ��rr1j' ��.rIBMr� -00 sop `9Cy v �•� °sa-33 �. Four Wheel Drive Road Citrin Residence.. • �. ALL6 Carbondale , . 81623 111,309,5251 Danielson155 record Pitkin County, Colorado Project Number: 1 0. Sheet 1 of 1 � i'J'KIN COL? N ONSITE WASTEWATER TREATMENT SYSTEM (OWTS) CONSTRUCTION PERMIT 76 Service Center Rd • Aspen, CO • 81611 Phone: 970.920.5070 Fax: 970.920.5374 Permit #: 0007.2016.pow2 Parcel ID #: 2643-351-08-001 Permit Issued: ®NEW CDU ❑REPAIR ❑REMODEL/ADDITION ❑TANK ONLY ❑FIELD ONLY ❑AMENDMENT Owner(s): 155 Danielson, LLC Property Address: Legal Description: Size of Lot: 2.11 155 Danielson Dr R-72 Acres Detached Accessory Unit: [-]YES ®NO Size of Building: 8613 ft2 Sq. Ft. Size of Accessory This system is designed for 5 bedrooms in the main home and a 1 bedroom future CDU. TANK PERMIT WILL BE REQUIRED FOR FUTURE CDU ADDITION Designed By: All Service Phone #: Fax #: LTAR: 0.6 Minimum Tank Capacity: Project #: C1030 Mailing Address: Email Address: Profile Hole Depth: 8 feet 2000 gallons Sq. Ft. Dated: October 21, 2014 Depth to Groundwater or Minimum Absorption 1208 ft2 Permit Conditions: ➢ 8 feet This OWTS Construction Permit is approved on the condition of compliance with the engineer design as submitted with the application and the specifications cited above. Changes must be approved by this Department and the engineer prior to construction. This system is designed to serve both a 5 bedroom main home and future 1 bedroom CDU. The field area is designed with future CDU flows, a tank will be required for the CDU. Sewage will flow via gravity to a 1500 -gallon two-compartment concrete septic tank with and effluent filter installed in the second compartment. Effluent will then flow to a 1000 -gallon two- compartment concrete septic tank with a screened dosing siphon in the second compartment. Effluent will be dosed to a baffled distribution box and then to a seven trench soil treatment area with 15 Quick -4 chambers in each trench (105 chambers total). Each trench will have observation ports at both ends. The soil treatment area shall be a minimum of 100 feet to any well, 20 feet to the drinking water line and 10 feet to the property line. All tank risers and distribution box must be accessible from grade. This Permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an "as -built" letter to this Department within 30 days of the final inspection, unless a longer period of time has been agreed upon, in writing. This Department must also be called for the final inspection with a minimum of 48 hours notice. Minimum horizontal distances between components of the system and physical features shall conform to the requirements of the Pitkin County OWTS Regulation. This Permit is conditioned upon the property owner(s) providing for regular inspection, cleaning, and maintenance of the system by qualified personnel, in accordance with the manufacturer's recommendations and the requirements of the Pitkin County OWTS Regulation. Issuance of this OWTS Construction Permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail. Issuance of this permit does not imply compliance with Pitkin County building and/or land use regulations, nor guarantee issuance of building and/or land use permits. THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN COUNTY OWTS REGULATION, INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE. Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Pitkin County OWTS Regulation. This Permit: will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built" drawing must be submitted and approved by EH before final approval of the system will be issued. Issued By: Bryan Daugherty, REHS Date: 10/13/16 Expires: 10/13/17 Installer: License #: Reactivation Authorized by: Final Approval Issued By: Date: New Expiration Date: Fem!! PaW ALL33 Four Wheel Drive Rd Carbondale, CO 81623 970.309-5259 September 14, 2016 Jeff and Rona Citrin 7 Dewart Road Greenwich, CT 06830 Subsurface Investigation and Onsite Wastewater Treatment System Design 5 -Bedroom Residence + Future 1 -Bedroom ADU 155 Danielson Drive Pitkin County, Colorado Jeff and Rona, Project No. C1030 ALL SERVICE septic, LLC performed a subsurface investigation and completed an onsite wastewater treatment system (OWTS) design for the subject residence. The property is located outside of Aspen, in an area where OWTSs are necessary. The residence is currently served by and will continue to be served by Starwood Metro District. The legal description of the property is Lot R-72, Block 11, Starwood Eleven, Starwood Subdivision. SITE CONDITIONS A single-family residence presently exists and a remodel is proposed. A 5 -bedroom residence with greater than 6000 square feet of living area will result from the remodel. A future 1 -bedroom additional dwelling unit (ADU) is also proposed. The existing OWTS will be abandoned and replaced with a new OWTS. An attempt was made to locate the existing tank by running a camera through the sewer line. The camera rari into standing water in the pipe at a point between the house and the tank. The existing tank must be located, pumped, and properly abandoned or removed. The existing absorption area can be abandoned in-place. The proposed soil treatment area (STA) slopes to the south. The proposed area is covered with native grasses and vegetation. SUBSURFACE The subsurface investigation was performed on August 14, 2103, prior to the adoption of the current Pitkin County OWTS Regulation, which now requires two soil profile test pit excavations. The subsurface was investigated by digging one 8 -foot soil profile hole and taking a soil sample from approximately 3 -feet below grade. A gradation analysis and hydrometer analysis was run by HP Geotech and results are detailed in a report dated August 22, 2013, Job No 113 064S. The materials encountered in the soil profile hole consisted of 6 -inches of topsoil, underlain by brown to reddish brown, dense, moist, sandy loam to maximum depth explored of 8.0 -feet. No bedrock or groundwater was encountered. A pipe was placed in the pit to monitor for groundwater. The gradation performed by HP Geotech shows the soil consists of 2% gravel, 62% sand, 31 % silt and 5% clay. The USDA soil type is classified as Sandy Loam. A long term acceptance rate (LTAR) of 0.60 gal/sq. ft will be used to design the OWTS, in accordance with Pitkin County OWTS Regulation, Table 6.28-7. 0 Page 2 August 14, 2013 / 8 -foot soil profile hole DESIGN SPECIFICATIONS The OWTS design is based on 5 -bedrooms having greater than 6000 square feet of living area and 1 - bedroom in the future, detached ADU. A design flow of 1150 GPD will be used. Design Calculations: (5 bedrooms x 100 GPD x 2 people/bedroom) + (1 bedroom x 75 GPD x 2 people/bedroom) = 1150 GPD Septic Tank Capacity Main House = 1000 gallons/day x 48 hour retention time = 2000 gallons minimum Septic Tank Capacity Future ADU = Min. 1000 -gallons STA Calculations = 1150 gallons/day / 0.60 SF/gallon (Sandy Loam Soil Type 2) = 1917 SF Dosed Chamber Trenches 1917 SF x 0.9 x 0.7 = 1208 SF 1208 SF / 12 SF/chamber = minimum 101 `Quick 4' Infiltrator® chambers The installation must include a 1500 -gallon, two-compartment concrete septic tank with an effluent filter, followed by a 1000 -gallon, two-compartment concrete septic tank with a screened dosing siphon in the second compartment. The dosing siphon should be set to discharge approximately 100 gallons/dose. Effluent will be dosed to a baffled distribution box, accessible from grade, and then to seven gravelless chamber trenches, each with 15 `Quick 4' Infiltrator® chambers. There must be at least 6 -feet of undisturbed soil between each trench. A minimum 1000 -gallon, two-compartment septic tank with an effluent filter will be installed upon construction of the ADU. A separate OWTS Construction Permit (tank only) must be obtained prior to installation of this septic tank. Prior to excavation, ALL SERVICE septic and the landscape architect should be consulted to verify locations of both the trenches and distribution lines to minimize disturbance. Page 3 The component manufacturers are typical of applications used by contractors and engineers in this area. Alternatives may be considered or recommended by contacting our office. Construction must be according to Pitkin County Onsite Wastewater Treatment System Regulations, the OWTS Construction Permit provided by Pitkin County Environmental Health Department, and this design. REVEGETATION REQUIREMENTS An adequate layer of good quality topsoil capable of supporting revegetation shall be placed over the entire disturbed area of the OWTS installation. A mixture of native grass seed that has good soil stabilizing characteristics (but without taproots), provides a maximum transpiration rate, and competes well with successional species. No trees or shrubs, or any vegetation requiring regular irritation shall be placed over the area. Until vegetation is reestablished, erosion and sediment control measures shall be implemented and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation cover. OPERATION INFORMATION AND MAINTENANCE The property owner shall be responsible for the operation and maintenance of each OWTS servicing the property. The property owner is responsible for maintaining service contracts for manufactured units, alternating STAB, and any other components needing maintenance. Geo -fabrics or plastics should not be used over the STA. No heavy equipment, machinery, or materials should be placed on backfilled STA. Livestock should not graze on the STA. Plumbing fixtures should be checked to ensure that no additional water is being discharged to OWTS. For example, a running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a STA. The homeowner should pump the septic tank every two years, or as needed gauged by measurement of solids in the tank. Garbage disposal use should be minimized, and non -biodegradable materials should not be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS. Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste only. ADDITIONAL CONSTRUCTION NOTES If design includes a pump, air release valves and weep holes must be installed to allow pump lines to drain to minimize risk of freezing. The pump shall be connected to a control breaker separate from the high water alarm breaker and from any other control system circuits. Excavation equipment must not drive in excavation of the STA due to the potential to compact soil. Extensions should be placed on all septic tank components to allow access to them from existing grade. Backfill over the STA must be uniform and granular with no material greater than minus 3 -inch. INSTALLATION OBSERVATIONS ALL SERVICE septic, LLC must view the OWTS during construction. The OWTS observation should be performed before backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing siphons, and other plumbing, as applicable, must also be observed. ALL SERVICE septic, LLC should be notified 48 hours in advance to observe the installation. Page 4 LIMITS: The design is based on information submitted. If soil conditions encountered are different from conditions described in report, ALL SERVICE septic, LLC should be notified. All OWTS construction must be according to the county regulations. Requirements not specified in this report must follow applicable county regulations. The installer should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. Please call with questions. Sincerely, ALL SERVICE septic, LLC Carla Ostberg, MPH, REHS Reviewed r Richard H Go ch HEPWORTH-PAWLAK August 22, 2013 C Hepworth-Pawlak Geotechnical, Inc. 5020 County Road 154 Glenwood Springs, Colorado 81601 Phone: 970-945-7988 Fax: 970-945-8454 Finail: hpgeo uhpgeotech.com CBO Inc. Attn: Carla Ostberg 33 Four Wheel Drive Road Carbondale, Colorado 81623 carla.ostberu�gmail com Job No. 113 0645 Subject: Laboratory Test Results, 155 Danielson Drive, Pitkin County, Colorado Dear Mrs. Ostberg: As requested, Hepworth-Pawlak Geotechnical, Inc. performed gradation analysis on a sample delivered to our laboratory by you. The services were performed in accordance with our agreement for professional engineering services to you, dated March 20, 2013. Results of the gradation analysis performed on the sample are presented on Figure 1. The USDA Soil Texture Classification is Sandy Loam. If you have any questions or need further assistance, please call our office. Sincerely, HEPWORTH — PAWLAK GEOTECHNICAL, INC. Louis E. Eller LEE/ksw attachment Figure 1 — USDA Soil Texture Gradation Test Results Parker 303-841-7119 - Colorado Springs 719-633-5562 • Silverthorne 970-468-1989 N 0' 20' 40' Scale: 1" = 40'-0" D U9 D 8595 I \ 859p 2 8585 W2.0 8585 8580 DROO � RE J ano n 0 I / / g56o N 04 I / g555 _� Ir / I / r � DRAWINGS MUST BE USED IN CONJUNCTION WITH DESIGN n SITE PLAN LETTER DATED 09/14/16 33 Four Wheel Drive Road Citrin Residence Revised: 09/14/16 Carbondale, CO 81623 Date: 09/13/13 970.309.5259 155 Danielson Drive Designed By: CBO V V I , /� / �1 .O SERVICE, carla@allserviceseptic.com Pitkin County, Colorado Reviewed By: RHP Project Number: C1030 Drawn By: ANG Sheet 1 of 4 N 0' 10' 20' Scale: 1" = 20'-0" 8570 i r IA DR -3 SEWER PIP WITH LEA UT (SLO E 2 huh DI TRIBUTION BOX GRAE / 00 a56 E, 150 GALL N, / TW -COM ART ENT / I CON RET SEP C TA K EXISTING 14'x 7f 000- ALL N, DRAIN FIELD T6 BE O- OMP RTM NT / ABANDONED/ .� ONC ETE EPT TA K WIT SqEE ED OSIN SIP ON / / s60 j g555 / D SD -35 E R E / / (SL E 1 o MI TO -BO ) / FL EN PIP S C NB / C B E IN 00 E T ENC / 85 ss % s / / / **A L T E CH N / IS IB TI N L NE O AT N / RIF D RI R / 5 XC VA 10 BY AL SE VI E / / iP epti A DL N SC PE / PVC RC IT CT 8 / O IL / H LE UIC -4' T D R H MB R T E H S.15C 9 E SP R INSPE GINNI P R S N 0Fa T N H 10 C SSM ER = / 26 S / ^ / EAC E n PROPOSED OWTS Four Wheel Drive Road Citrin Residence Revised: 09/14/16 AL�33 Carbondale, CO 81623 970.309.5259 155 Danielson Drive Date: 09/13/13 W2.0rla@allservicesepitacom 4 Pitkin County, Colorado Designed By: CBO h j Ca SERVICE Reviewed By: RHP Project Number: C1030 Drawn By: ANG Sheet 2 of 4 T�HC�L` 5 -BEDROOM RESIDENCE GREATER THAN 6000 SF LIVING AREA + FUTURE DETACHED 1 -BEDROOM ADU (100 GPD x 2 PERSONS/BEDROOM x 5 BEDROOMS) + (75 GPD X 2 PERSONS/BEDROOM X 1 BEDROOM) DESIGN FLOW = 1150 GALLONS/DAY TANK: 1000 x 48 HOUR RETENTION TIME = 2000 GALLONS USE 1500 -GALLON, TWO-COMPARTMENT TANK FOLLOWED BY A 1000 -GALLON, TWO-COMPARTMENT TANK WITH DOSING SIPHON (TANK TO SERVE FUTURE ADU MIN. 1000 -GALLONS) ABSORPTION AREA: LONG TERM ACCEPTANCE RATE (LTAR) = 0.6 GAL/ SQ FT CALCULATED ABSORPTION AREA = Q/LTAR = 1150 GPD /0.6 GAL/SF DOSED CHAMBER TRENCHES 1917 X 0.9 X 0.7 = 1208 SF 1208 SF / 12 SF/CHAMBER = MIN. 101 7 TRENCHES, 15'QUICK 4' CHAMBERS EACH TnTAI Ing T)l Ilral d' C.W ARARPP_Q PLAN VIEW -TYP. DISTRIBUTION 4"EFFLUENT PIPE BOX ACCESSIBLE FROM SEPTIC TANK FROM GRADE 4" SDR 35 SEWER CHAMBER TRENCH CROSS SECTION -TYP. INFILTRATOR(R) QUICK4 TM CUT SHEET 4" PVC PIPES PLACED IN TOP PORT OF OBERVATION CHAMBEREND INSPECTION PORTS AT PLATES 52" 52 PIPE BEGINNING AND END OF 4" PVC \\ (E F CT VEL NG ) OBERVATION PIPE 72„ 34,,, � 3 5' max UNDISTURBED SOIL I( 2'm in I6° CHAMBER (4'x 3') INFILTRATOR END PLATE 6' min LIMIT OF ---��{ll LINES TO ENTER EXCAVATION AND EXIT IN TOP SCARIFY SURFACE GRAVELLESS'QUICK-4' CHAMBER (4' x 3') PORT OF CHAMBER END PLATE PLAN VIEW -TYP. DISTRIBUTION 4"EFFLUENT PIPE BOX ACCESSIBLE FROM SEPTIC TANK FROM GRADE n TRENCH DETAILS J ALL 33 Four Wheel Drive Road Citrin Residence Revised: 09/14/16 Carbondale, CO 81623 155 Danielson Drive Date: 09;13113 SfBYICf h I 970.309.5259 Pitkin County, Colorado Designed By: CBO W3.0 eada@allserviceseptic.com Checked By: RHP Project Number: C1030 Drawn By: ANG Shect 3 0`4 4" SDR 35 SEWER PIPES FROM D -BOX TO TRENCHES (MIN 1%) PIPES PLACED IN TOP PORT OF CHAMBEREND INSPECTION PORTS AT PLATES BEGINNING AND END OF FFLUENT PIPES MAY BE EACH TRENCH GROUPED INTO ONE TRENCH 15 CHAMBERS PER TRENCH GRAVELLESS'QUICK-4' 6' min CHAMBER (4'x 3') INFILTRATOR END PLATE n TRENCH DETAILS J ALL 33 Four Wheel Drive Road Citrin Residence Revised: 09/14/16 Carbondale, CO 81623 155 Danielson Drive Date: 09;13113 SfBYICf h I 970.309.5259 Pitkin County, Colorado Designed By: CBO W3.0 eada@allserviceseptic.com Checked By: RHP Project Number: C1030 Drawn By: ANG Shect 3 0`4 n CLEANOUT DETAIL NOT TO sC­ BOX AND COVER BROUGHT TO GRADE CONCRETE LID FINISHED GRADE 0000 INLET OUTLETS DISTRIBUTION BOX BAFFLE n D—BOX DETAIL Septic Tank with the Addition of an Effluent Filter -1500 Gallon, 2 -Cam SLIP-ON PVC CAP DO NOT GLUE FINISHED Filter Cartridge Handle GRADE (field cut to desired height) Top of tee to come to 1' from top of tank lid EFFLUENT LINE - 4" Inlet Tee SCHEDULE 40 OR 4" SDR SEWER LINE - 35 P.V.C. 4" SCHEDULE Liquid Level � 40 P.V.C. INSULATED COPPER TRACER WIRE MAY BE INSTALLED TO LOCATE LINE IN FUTURE n CLEANOUT DETAIL NOT TO sC­ BOX AND COVER BROUGHT TO GRADE CONCRETE LID FINISHED GRADE 0000 INLET OUTLETS DISTRIBUTION BOX BAFFLE n D—BOX DETAIL Septic Tank with the Addition of an Effluent Filter -1500 Gallon, 2 -Cam ORENCO BRAND NAME NOT ENFORCED n TANK DETAIL FAw Cartridge Effluent Fater 31,and 4" Dia. Dosing Siphon System -1000 gallon, two-compartment Cocre n TANK DETAIL xor ro scuc i Grommet(s) adapter with adhesive) (cast or tatted) hylene screen urge dia. transport line required) ALL 33 Four Wheel Drive Road Citrin Residence Revised: 09/14/16 Carbondale, O 81623 Date: 09/13/13 970.309.5259 155 Danielson Drive W4.0 /\ / ^ . O Carla@allserviceseptic.com SfNYl6f Pitkin County, Colorado Designed By: CBO �/ �/ �} Checked By: RHP Project Number: C1030 Drawn By: ANG Sheet 4 of 4 lope Ground \ / Away From Risers A Filter Cartridge Handle (field cut to desired height) Top of tee to come to 1' from top of tank lid Tank Adapter (cast or bolted) Inlet Tee Vent Orifice Effluent Discharge Liquid Level � 2' Modulating Discharge Orifices Vault Inlet Ports ORENCO BRAND NAME NOT ENFORCED n TANK DETAIL FAw Cartridge Effluent Fater 31,and 4" Dia. Dosing Siphon System -1000 gallon, two-compartment Cocre n TANK DETAIL xor ro scuc i Grommet(s) adapter with adhesive) (cast or tatted) hylene screen urge dia. transport line required) ALL 33 Four Wheel Drive Road Citrin Residence Revised: 09/14/16 Carbondale, O 81623 Date: 09/13/13 970.309.5259 155 Danielson Drive W4.0 /\ / ^ . O Carla@allserviceseptic.com SfNYl6f Pitkin County, Colorado Designed By: CBO �/ �/ �} Checked By: RHP Project Number: C1030 Drawn By: ANG Sheet 4 of 4 Pitkin County Environmental Health Department Contact Log Sheet Name: Parcel ID#: Address: Dat, Person S 9ken; To - Com vments / Aetion to be Taker}., __-._:. _._-_..__ _ . _ . initials Time ZD- s . _ \ a ave ' Q 1 1. to vire k