HomeMy WebLinkAboutpitkin.eh.264335108001 (2016)iTKIN
COUNT
NSITE WASTEWATER TREAT, --.:NT SYSTEM (OWTS)
CONSTRUCTION PERMIT
76 Service Center Rd- Aspen, CO - 81611
Phone: 970.920.5070 Fax: 970.920.5374
Permit #: 0007.2016.pow2 Parcel ID #:
2643-351-08-001
Permit Issued: ®NEW CDU [-]REPAIR ❑REMODEL/ADDITION ❑TANK ONLY ❑FIELD ONLY ❑AMENDMENT
Owner(s): 155 Danielson, LLC
Property Address: 155 Danielson Dr
Legal Description: R-72
Size of Lot: 2.11
Size of Building:
8613 ft2
Acres Detached Accessory Unit: ❑YES ®NO
Sq. Ft. Size of Accessory
This system is designed for 5 bedrooms in the main home and a 1 bedroom future CDU.
TANK PERMIT WILL BE REQUIRED FOR FUTURE CDU ADDITION
Designed By: All Service Septic Project #: _
Phone #: Mailing Address:
Fax #: Email Address:
LTAR: 0.6 Profile Hole Depth: 8 feet
Minimum Tank Capacity: 2000 gallons
Sq. Ft.
C1030 Dated: October 21, 2014
Depth to Groundwater or
Minimum Absorption 1208 ftz
Permit Conditions:
➢ 8 feet
This OWTS Construction Permit is approved on the condition of compliance with the engineer design as submitted with the application and the
specifications cited above. Changes must be approved by this Department and the engineer prior to construction.
This system is designed to serve both a 5 bedroom main home and future 1 bedroom CDU. The field area is designed with
future CDU flows, a tank will be required for the CDU. Sewage will flow via gravity to a 1500 -gallon two-compartment
concrete septic tank with and effluent filter installed in the second compartment. Effluent will then flow to a 1000 -gallon two-
compartment concrete septic tank with a screened dosing siphon in the second compartment. Effluent will be dosed to a
baffled distribution box and then to a seven trench soil treatment area with 15 Quick -4 chambers in each trench (90
chambers total). Each trench will have observation ports at both ends. The soil treatment area shall be a minimum of 100
feet to any well, 20 feet to the drinking water line and 10 feet to the property line. All tank risers and distribution box must
be accessible from grade.
This Permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an "as -built" letter to this
Department within 30 days of the final inspection, unless a longer period of time has been agreed upon, in writing. This Department must also be called
for the final inspection with a minimum of 48 hours notice.
Minimum horizontal distances between components of the system and physical features shall conform to the requirements of the Pitkin County OWTS
Regulation.
This Permit is conditioned upon the property owner(s) providing for regular inspection, cleaning, and maintenance of the system by qualified personnel, in
accordance with the manufacturer's recommendations and the requirements of the Pitkin County OWTS Regulation. Issuance of this OWTS Construction
Permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail. Issuance of
this permit does not imply compliance with Pitkin County building and/or land use regulations, nor guarantee issuance of building and/or land use permits.
THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN
COUNTY OWTS REGULATION, INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE.
Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is
hereby given to the property owner(s) to perform the work indicated in accordance with the Pitkin County OWTS
Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced.
An "as -built" drawing must be submitted and approved by EH before final approval of the system will be issued.
Issued By: Kurt Dahl, REHS Date: 2/27/2015 Expires: 02/27/2016
Installgr. License #: Reactivation Authorized by:
'r4 .l.>&a/� .��Ci 4XJ K L µ� �l .i I� ❑FcePard
l
P]
000--1-2016. POw1 Z
REQUEST FOR AN AMENDMENT TO AN
MEHf OWTS CONSTRUCTION PERMIT
76 Service Center Rd • Aspen, CO •81611
Phone: 970.920.5070 Fax: 970.920.5374
This form should be used for requesting an amendment to on OWTS Construction Permit if there have been significant
changes to an OWTS design that differ from what was approved as part of the OWTS Construction Permit. An hourly fee of
$262/hour will be invoiced upon review of the new design and reissuance of the amended permit. The system requirements
must conform to the current OWTS Regulation, which can be found at
http•//www aspenpitkin com/P4 sIdepts112fowtsreq.pdf.
Permit Number for Which Amendment is Requested tt 2Q
4_QV\') T
Parcel 1D# (available from the Piddn County Assessor's Office 'ff
970-920-5160 or at www_pitkjnassessor.org): Z �j �i 091
Example:
Property Address: 19D
q L v-0 n
Lot: —� 2 Block: Filing: l Subdivi "on:__
' ( r � ^ t 1
Building Permit #:
C7 k)--20tc-PVQVC.
'roperty Owner(s); Email Address:
155 bumf % � � Ti LLL
)wner's Mailing Address: . e W 'C n City, State, Zip/1�Qri W It
tome Phone: Business Phone: D J
Primary Contact Person/Applicant (V not owner):. Company:
e Yl
Contact/Applicant Mailing Address: City, State, Zip:
Cell Phone: 21 Business Phone:
rFaxNumber: Email Address:
r ss iii r.
'LEASE READ BEFORE SIGNING:
certify that the above information is complete and accurate. 1 acknowledge that EH/NR may revoke any permit 1 am
ssued if my application is found to contain any inaccurate, false, or misleading information, i understand that no
:onstruction may be undertaken on the OWTS until the OWTS Construction Permit is amended or a new permit is issues
j ry j
Owner/Applicant Signature
OFFICE USE ONLY:
911911
Date
Recived by: Date:
Invoice #: Invoice amount: Date received:
e
ALL33 Four Wheel Drive Rd
CQrbondole, CO 81623
970-309-5259
June 17, 2017
Jeff and Rona Citrin
7 Dewart Road
Greenwich, CT 06830
Onsite Wastewater Treatment System (OWTS) Installation Observations
155 Danielson Drive
Pitkin County, Colorado
OWTS Construction Permit Number 007.2016.POW2
Jeff and Rona,
Project No. C1030
ALL SERVICE septic, LLC observed the installation of the onsite wastewater treatment system (OWTS)
on June 6, 2015 and September 13, 2016 for the subject property. Excavation Services installed the
system.
The existing septic tank was removed and the existing soil treatment area (STA) was abandoned in
place.
The installation of the new OWTS included a 1500 -gallon, two-compartment concrete septic tank with an
effluent filter, followed by a 1000 -gallon, two-compartment concrete septic tank with a screened dosing
siphon in the second compartment. The dosing siphon was set to discharge approximately 100
gallons/dose. The siphon was tested at the time of our September 13, 2016 visit. Effluent is dosed to a
baffled distribution box, accessible from grade, and then to seven gravelless chamber trenches, each
with 15 'Quick 4' Infiltrator® chambers. There was a minimum of 6 -feet of undisturbed soil between each
trench. Inspection ports were installed at the beginning and end of each trench.
The OWTS was generally installed according to specifications. This observation is not a guarantee of
workmanship and/or parts and materials. ALL SERVICE septic, LLC should be notified if changes are
made to the OWTS in the future. Any additional OWTS construction must be according to the county
regulations.
LIMITS:
Observations are limited to components that are visible at the time of the inspection. The installer must
have documented and demonstrated knowledge of the requirements and regulations of the county in
which they are working. The quality of the installation is dependent of the expertise of the installer, soil
type, and weather conditions.
Please call with questions.
Sincerely,
ALL SERVICE septic, LLC
Carla Ostberg, MPH, REHS
Reviewed
Richard H
1500 -gallon tank followed by a 1000 -gallon tank with dosing siphon.
Inlet pipe and clean out
Sewer pipe exiting dosing tank
Inlet tee
Distribution box
x:
Effluent filter
..ter
w
Trenchpreparation
r
Chamber trenches with inspection ports Well -bedded pipes from d -box to trenches
N
()'10'
20'
Scale: V= 20'-0"
858k
�;-
.
MEMORIES-
--�/
��rr1j'
��.rIBMr�
-00
sop
`9Cy
v
�•�
°sa-33
�.
Four Wheel Drive Road
Citrin Residence..
• �.
ALL6
Carbondale , . 81623
111,309,5251
Danielson155
record
Pitkin County, Colorado
Project Number: 1
0.
Sheet 1 of 1
� i'J'KIN
COL? N
ONSITE WASTEWATER TREATMENT SYSTEM (OWTS)
CONSTRUCTION PERMIT
76 Service Center Rd • Aspen, CO • 81611
Phone: 970.920.5070 Fax: 970.920.5374
Permit #: 0007.2016.pow2 Parcel ID #:
2643-351-08-001
Permit Issued: ®NEW CDU ❑REPAIR ❑REMODEL/ADDITION ❑TANK ONLY ❑FIELD ONLY ❑AMENDMENT
Owner(s):
155 Danielson, LLC
Property Address:
Legal Description:
Size of Lot: 2.11
155 Danielson Dr
R-72
Acres Detached Accessory Unit: [-]YES ®NO
Size of Building: 8613 ft2 Sq. Ft. Size of Accessory
This system is designed for 5 bedrooms in the main home and a 1 bedroom future CDU.
TANK PERMIT WILL BE REQUIRED FOR FUTURE CDU ADDITION
Designed By: All Service
Phone #:
Fax #:
LTAR: 0.6
Minimum Tank Capacity:
Project #: C1030
Mailing Address:
Email Address:
Profile Hole Depth: 8 feet
2000 gallons
Sq. Ft.
Dated: October 21, 2014
Depth to Groundwater or
Minimum Absorption 1208 ft2
Permit Conditions:
➢ 8 feet
This OWTS Construction Permit is approved on the condition of compliance with the engineer design as submitted with the application and the
specifications cited above. Changes must be approved by this Department and the engineer prior to construction.
This system is designed to serve both a 5 bedroom main home and future 1 bedroom CDU. The field area is designed with
future CDU flows, a tank will be required for the CDU. Sewage will flow via gravity to a 1500 -gallon two-compartment
concrete septic tank with and effluent filter installed in the second compartment. Effluent will then flow to a 1000 -gallon two-
compartment concrete septic tank with a screened dosing siphon in the second compartment. Effluent will be dosed to a
baffled distribution box and then to a seven trench soil treatment area with 15 Quick -4 chambers in each trench (105
chambers total). Each trench will have observation ports at both ends. The soil treatment area shall be a minimum of 100
feet to any well, 20 feet to the drinking water line and 10 feet to the property line. All tank risers and distribution box must
be accessible from grade.
This Permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an "as -built" letter to this
Department within 30 days of the final inspection, unless a longer period of time has been agreed upon, in writing. This Department must also be called
for the final inspection with a minimum of 48 hours notice.
Minimum horizontal distances between components of the system and physical features shall conform to the requirements of the Pitkin County OWTS
Regulation.
This Permit is conditioned upon the property owner(s) providing for regular inspection, cleaning, and maintenance of the system by qualified personnel, in
accordance with the manufacturer's recommendations and the requirements of the Pitkin County OWTS Regulation. Issuance of this OWTS Construction
Permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail. Issuance of
this permit does not imply compliance with Pitkin County building and/or land use regulations, nor guarantee issuance of building and/or land use permits.
THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN
COUNTY OWTS REGULATION, INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE.
Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is
hereby given to the property owner(s) to perform the work indicated in accordance with the Pitkin County OWTS
Regulation. This Permit: will expire 1 year from the date of issuance unless construction on the system has commenced.
An "as -built" drawing must be submitted and approved by EH before final approval of the system will be issued.
Issued By: Bryan Daugherty, REHS Date: 10/13/16 Expires:
10/13/17
Installer: License #:
Reactivation Authorized by:
Final Approval Issued By: Date:
New Expiration Date: Fem!! PaW
ALL33 Four Wheel Drive Rd
Carbondale, CO 81623
970.309-5259
September 14, 2016
Jeff and Rona Citrin
7 Dewart Road
Greenwich, CT 06830
Subsurface Investigation and Onsite Wastewater Treatment System Design
5 -Bedroom Residence + Future 1 -Bedroom ADU
155 Danielson Drive
Pitkin County, Colorado
Jeff and Rona,
Project No. C1030
ALL SERVICE septic, LLC performed a subsurface investigation and completed an onsite wastewater
treatment system (OWTS) design for the subject residence. The property is located outside of Aspen, in
an area where OWTSs are necessary. The residence is currently served by and will continue to be
served by Starwood Metro District.
The legal description of the property is Lot R-72, Block 11, Starwood Eleven, Starwood Subdivision.
SITE CONDITIONS
A single-family residence presently exists and a remodel is proposed. A 5 -bedroom residence with
greater than 6000 square feet of living area will result from the remodel. A future 1 -bedroom additional
dwelling unit (ADU) is also proposed. The existing OWTS will be abandoned and replaced with a new
OWTS. An attempt was made to locate the existing tank by running a camera through the sewer line.
The camera rari into standing water in the pipe at a point between the house and the tank. The existing
tank must be located, pumped, and properly abandoned or removed. The existing absorption area can
be abandoned in-place.
The proposed soil treatment area (STA) slopes to the south. The proposed area is covered with native
grasses and vegetation.
SUBSURFACE
The subsurface investigation was performed on August 14, 2103, prior to the adoption of the current Pitkin
County OWTS Regulation, which now requires two soil profile test pit excavations.
The subsurface was investigated by digging one 8 -foot soil profile hole and taking a soil sample from
approximately 3 -feet below grade. A gradation analysis and hydrometer analysis was run by HP Geotech
and results are detailed in a report dated August 22, 2013, Job No 113 064S.
The materials encountered in the soil profile hole consisted of 6 -inches of topsoil, underlain by brown to
reddish brown, dense, moist, sandy loam to maximum depth explored of 8.0 -feet. No bedrock or
groundwater was encountered. A pipe was placed in the pit to monitor for groundwater. The gradation
performed by HP Geotech shows the soil consists of 2% gravel, 62% sand, 31 % silt and 5% clay. The
USDA soil type is classified as Sandy Loam. A long term acceptance rate (LTAR) of 0.60 gal/sq. ft
will be used to design the OWTS, in accordance with Pitkin County OWTS Regulation, Table 6.28-7.
0
Page 2
August 14, 2013 / 8 -foot soil profile hole
DESIGN SPECIFICATIONS
The OWTS design is based on 5 -bedrooms having greater than 6000 square feet of living area and 1 -
bedroom in the future, detached ADU. A design flow of 1150 GPD will be used.
Design Calculations:
(5 bedrooms x 100 GPD x 2 people/bedroom) + (1 bedroom x 75 GPD x 2 people/bedroom) = 1150 GPD
Septic Tank Capacity Main House = 1000 gallons/day x 48 hour retention time = 2000 gallons minimum
Septic Tank Capacity Future ADU = Min. 1000 -gallons
STA Calculations = 1150 gallons/day / 0.60 SF/gallon (Sandy Loam Soil Type 2) = 1917 SF
Dosed Chamber Trenches 1917 SF x 0.9 x 0.7 = 1208 SF
1208 SF / 12 SF/chamber = minimum 101 `Quick 4' Infiltrator® chambers
The installation must include a 1500 -gallon, two-compartment concrete septic tank with an effluent filter,
followed by a 1000 -gallon, two-compartment concrete septic tank with a screened dosing siphon in the
second compartment. The dosing siphon should be set to discharge approximately 100 gallons/dose.
Effluent will be dosed to a baffled distribution box, accessible from grade, and then to seven gravelless
chamber trenches, each with 15 `Quick 4' Infiltrator® chambers. There must be at least 6 -feet of
undisturbed soil between each trench.
A minimum 1000 -gallon, two-compartment septic tank with an effluent filter will be installed upon
construction of the ADU. A separate OWTS Construction Permit (tank only) must be obtained prior to
installation of this septic tank.
Prior to excavation, ALL SERVICE septic and the landscape architect should be consulted to
verify locations of both the trenches and distribution lines to minimize disturbance.
Page 3
The component manufacturers are typical of applications used by contractors and engineers in this area.
Alternatives may be considered or recommended by contacting our office. Construction must be
according to Pitkin County Onsite Wastewater Treatment System Regulations, the OWTS Construction
Permit provided by Pitkin County Environmental Health Department, and this design.
REVEGETATION REQUIREMENTS
An adequate layer of good quality topsoil capable of supporting revegetation shall be placed over the entire
disturbed area of the OWTS installation. A mixture of native grass seed that has good soil stabilizing
characteristics (but without taproots), provides a maximum transpiration rate, and competes well with
successional species. No trees or shrubs, or any vegetation requiring regular irritation shall be placed over
the area. Until vegetation is reestablished, erosion and sediment control measures shall be implemented
and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation
cover.
OPERATION INFORMATION AND MAINTENANCE
The property owner shall be responsible for the operation and maintenance of each OWTS servicing the
property. The property owner is responsible for maintaining service contracts for manufactured units,
alternating STAB, and any other components needing maintenance.
Geo -fabrics or plastics should not be used over the STA. No heavy equipment, machinery, or materials
should be placed on backfilled STA. Livestock should not graze on the STA. Plumbing fixtures should be
checked to ensure that no additional water is being discharged to OWTS. For example, a running toilet or
leaky faucet can discharge hundreds of gallons of water a day and harm a STA.
The homeowner should pump the septic tank every two years, or as needed gauged by measurement of
solids in the tank. Garbage disposal use should be minimized, and non -biodegradable materials should not
be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener
should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS.
Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste
only.
ADDITIONAL CONSTRUCTION NOTES
If design includes a pump, air release valves and weep holes must be installed to allow pump lines to
drain to minimize risk of freezing. The pump shall be connected to a control breaker separate from the
high water alarm breaker and from any other control system circuits. Excavation equipment must not
drive in excavation of the STA due to the potential to compact soil. Extensions should be placed on all
septic tank components to allow access to them from existing grade. Backfill over the STA must be
uniform and granular with no material greater than minus 3 -inch.
INSTALLATION OBSERVATIONS
ALL SERVICE septic, LLC must view the OWTS during construction. The OWTS observation should be
performed before backfill, after placement of OWTS components. Septic tanks, distribution devices,
pumps, dosing siphons, and other plumbing, as applicable, must also be observed. ALL SERVICE septic,
LLC should be notified 48 hours in advance to observe the installation.
Page 4
LIMITS:
The design is based on information submitted. If soil conditions encountered are different from conditions
described in report, ALL SERVICE septic, LLC should be notified. All OWTS construction must be
according to the county regulations. Requirements not specified in this report must follow applicable
county regulations. The installer should have documented and demonstrated knowledge of the
requirements and regulations of the county in which they are working.
Please call with questions.
Sincerely,
ALL SERVICE septic, LLC
Carla Ostberg, MPH, REHS
Reviewed
r
Richard H
Go ch
HEPWORTH-PAWLAK
August 22, 2013
C
Hepworth-Pawlak Geotechnical, Inc.
5020 County Road 154
Glenwood Springs, Colorado 81601
Phone: 970-945-7988
Fax: 970-945-8454
Finail: hpgeo uhpgeotech.com
CBO Inc.
Attn: Carla Ostberg
33 Four Wheel Drive Road
Carbondale, Colorado 81623
carla.ostberu�gmail com
Job No. 113 0645
Subject: Laboratory Test Results, 155 Danielson Drive, Pitkin County, Colorado
Dear Mrs. Ostberg:
As requested, Hepworth-Pawlak Geotechnical, Inc. performed gradation analysis on a
sample delivered to our laboratory by you. The services were performed in accordance with
our agreement for professional engineering services to you, dated March 20, 2013.
Results of the gradation analysis performed on the sample are presented on Figure 1. The
USDA Soil Texture Classification is Sandy Loam.
If you have any questions or need further assistance, please call our office.
Sincerely,
HEPWORTH — PAWLAK GEOTECHNICAL, INC.
Louis E. Eller
LEE/ksw
attachment Figure 1 — USDA Soil Texture Gradation Test Results
Parker 303-841-7119 - Colorado Springs 719-633-5562 • Silverthorne 970-468-1989
N
0' 20' 40'
Scale: 1" = 40'-0"
D U9
D
8595
I
\ 859p
2 8585
W2.0
8585
8580
DROO �
RE
J
ano n
0
I / /
g56o N
04
I / g555
_� Ir
/ I /
r �
DRAWINGS MUST BE USED IN
CONJUNCTION WITH DESIGN
n SITE PLAN LETTER DATED 09/14/16
33 Four Wheel Drive Road Citrin Residence Revised: 09/14/16
Carbondale, CO 81623 Date: 09/13/13
970.309.5259 155 Danielson Drive Designed By: CBO V V I , /� / �1 .O
SERVICE, carla@allserviceseptic.com Pitkin County, Colorado
Reviewed By: RHP
Project Number: C1030 Drawn By: ANG Sheet 1 of 4
N
0' 10' 20'
Scale: 1" = 20'-0"
8570 i
r
IA DR -3 SEWER PIP
WITH LEA UT
(SLO E 2
huh
DI TRIBUTION BOX
GRAE
/
00
a56
E,
150 GALL N,
/
TW -COM ART ENT
/ I
CON RET SEP C TA K
EXISTING 14'x 7f
000- ALL N,
DRAIN FIELD T6 BE
O- OMP RTM NT
/ ABANDONED/
.�
ONC ETE EPT TA K WIT
SqEE ED OSIN SIP ON
/
/
s60
j
g555
/
D SD -35 E R E /
/
(SL E 1 o MI TO -BO )
/
FL EN PIP S C NB
/
C B E IN 00 E T ENC /
85
ss
%
s /
/
/
**A L T E CH N
/
IS IB TI N L NE O AT N /
RIF D RI R
/ 5
XC VA 10 BY AL SE VI E /
/
iP
epti A DL N SC PE /
PVC
RC IT CT
8
/
O IL
/
H LE
UIC -4' T D R H MB R
T E H S.15C 9 E SP R
INSPE
GINNI
P R S
N 0Fa
T N H 10 C SSM ER = /
26 S /
^
/ EAC E
n PROPOSED OWTS
Four Wheel Drive Road
Citrin Residence
Revised: 09/14/16
AL�33
Carbondale, CO 81623
970.309.5259
155 Danielson Drive
Date: 09/13/13
W2.0rla@allservicesepitacom
4
Pitkin County, Colorado
Designed By: CBO
h j Ca
SERVICE
Reviewed By: RHP
Project Number: C1030
Drawn By: ANG
Sheet 2 of 4
T�HC�L`
5 -BEDROOM RESIDENCE GREATER THAN 6000 SF LIVING AREA +
FUTURE DETACHED 1 -BEDROOM ADU
(100 GPD x 2 PERSONS/BEDROOM x 5 BEDROOMS) + (75 GPD X 2
PERSONS/BEDROOM X 1 BEDROOM)
DESIGN FLOW = 1150 GALLONS/DAY
TANK:
1000 x 48 HOUR RETENTION TIME = 2000 GALLONS
USE 1500 -GALLON, TWO-COMPARTMENT TANK FOLLOWED BY A
1000 -GALLON, TWO-COMPARTMENT TANK WITH DOSING SIPHON
(TANK TO SERVE FUTURE ADU MIN. 1000 -GALLONS)
ABSORPTION AREA:
LONG TERM ACCEPTANCE RATE (LTAR) = 0.6 GAL/ SQ FT
CALCULATED ABSORPTION AREA = Q/LTAR = 1150 GPD /0.6 GAL/SF
DOSED CHAMBER TRENCHES 1917 X 0.9 X 0.7 = 1208 SF
1208 SF / 12 SF/CHAMBER = MIN. 101
7 TRENCHES, 15'QUICK 4' CHAMBERS EACH
TnTAI Ing T)l Ilral d' C.W ARARPP_Q
PLAN VIEW -TYP.
DISTRIBUTION 4"EFFLUENT PIPE
BOX ACCESSIBLE FROM SEPTIC TANK
FROM GRADE
4" SDR 35 SEWER
CHAMBER TRENCH CROSS SECTION -TYP.
INFILTRATOR(R) QUICK4
TM CUT SHEET 4" PVC
PIPES PLACED IN
TOP PORT OF
OBERVATION
CHAMBEREND
INSPECTION PORTS AT PLATES
52"
52 PIPE
BEGINNING AND END OF
4" PVC
\\
(E F CT VEL NG )
OBERVATION
PIPE
72„ 34,,,
�
3 5' max UNDISTURBED
SOIL
I(
2'm in
I6°
CHAMBER (4'x 3')
INFILTRATOR
END PLATE
6' min
LIMIT OF
---��{ll
LINES TO ENTER
EXCAVATION
AND EXIT IN TOP
SCARIFY SURFACE
GRAVELLESS'QUICK-4'
CHAMBER (4' x 3')
PORT OF CHAMBER
END PLATE
PLAN VIEW -TYP.
DISTRIBUTION 4"EFFLUENT PIPE
BOX ACCESSIBLE FROM SEPTIC TANK
FROM GRADE
n TRENCH DETAILS
J
ALL 33 Four Wheel Drive Road Citrin Residence Revised: 09/14/16
Carbondale, CO 81623 155 Danielson Drive Date: 09;13113
SfBYICf h I 970.309.5259 Pitkin County, Colorado Designed By: CBO W3.0
eada@allserviceseptic.com Checked By: RHP
Project Number: C1030 Drawn By: ANG Shect 3 0`4
4" SDR 35 SEWER
PIPES FROM D -BOX TO
TRENCHES (MIN 1%)
PIPES PLACED IN
TOP PORT OF
CHAMBEREND
INSPECTION PORTS AT PLATES
BEGINNING AND END OF
FFLUENT PIPES MAY BE
EACH TRENCH
GROUPED INTO ONE
TRENCH
15 CHAMBERS PER TRENCH
GRAVELLESS'QUICK-4'
6' min
CHAMBER (4'x 3')
INFILTRATOR
END PLATE
n TRENCH DETAILS
J
ALL 33 Four Wheel Drive Road Citrin Residence Revised: 09/14/16
Carbondale, CO 81623 155 Danielson Drive Date: 09;13113
SfBYICf h I 970.309.5259 Pitkin County, Colorado Designed By: CBO W3.0
eada@allserviceseptic.com Checked By: RHP
Project Number: C1030 Drawn By: ANG Shect 3 0`4
n CLEANOUT DETAIL
NOT TO sC
BOX AND COVER BROUGHT TO GRADE
CONCRETE LID
FINISHED GRADE
0000 INLET
OUTLETS
DISTRIBUTION BOX BAFFLE
n D—BOX DETAIL
Septic Tank with the Addition of an Effluent Filter -1500 Gallon, 2 -Cam
SLIP-ON PVC CAP
DO NOT GLUE
FINISHED
Filter Cartridge Handle
GRADE
(field cut to desired height)
Top of tee to come to
1' from top of tank lid
EFFLUENT LINE - 4"
Inlet Tee
SCHEDULE 40 OR 4" SDR
SEWER LINE -
35 P.V.C.
4" SCHEDULE
Liquid Level
�
40 P.V.C.
INSULATED COPPER TRACER
WIRE MAY BE INSTALLED TO
LOCATE LINE IN FUTURE
n CLEANOUT DETAIL
NOT TO sC
BOX AND COVER BROUGHT TO GRADE
CONCRETE LID
FINISHED GRADE
0000 INLET
OUTLETS
DISTRIBUTION BOX BAFFLE
n D—BOX DETAIL
Septic Tank with the Addition of an Effluent Filter -1500 Gallon, 2 -Cam
ORENCO BRAND NAME
NOT ENFORCED
n TANK DETAIL
FAw Cartridge
Effluent Fater
31,and 4" Dia. Dosing Siphon System -1000 gallon, two-compartment
Cocre
n TANK DETAIL
xor ro scuc
i Grommet(s)
adapter with
adhesive)
(cast or tatted)
hylene screen
urge
dia. transport line required)
ALL 33 Four Wheel Drive Road Citrin Residence Revised: 09/14/16
Carbondale, O 81623 Date: 09/13/13
970.309.5259 155 Danielson Drive W4.0 /\ / ^ . O
Carla@allserviceseptic.com
SfNYl6f Pitkin County, Colorado Designed By: CBO �/ �/ �}
Checked By: RHP
Project Number: C1030 Drawn By: ANG Sheet 4 of 4
lope Ground
\
/ Away From Risers
A
Filter Cartridge Handle
(field cut to desired height)
Top of tee to come to
1' from top of tank lid
Tank Adapter (cast or bolted)
Inlet Tee
Vent Orifice
Effluent Discharge
Liquid Level
�
2' Modulating Discharge Orifices
Vault Inlet Ports
ORENCO BRAND NAME
NOT ENFORCED
n TANK DETAIL
FAw Cartridge
Effluent Fater
31,and 4" Dia. Dosing Siphon System -1000 gallon, two-compartment
Cocre
n TANK DETAIL
xor ro scuc
i Grommet(s)
adapter with
adhesive)
(cast or tatted)
hylene screen
urge
dia. transport line required)
ALL 33 Four Wheel Drive Road Citrin Residence Revised: 09/14/16
Carbondale, O 81623 Date: 09/13/13
970.309.5259 155 Danielson Drive W4.0 /\ / ^ . O
Carla@allserviceseptic.com
SfNYl6f Pitkin County, Colorado Designed By: CBO �/ �/ �}
Checked By: RHP
Project Number: C1030 Drawn By: ANG Sheet 4 of 4
Pitkin County Environmental Health Department
Contact Log Sheet
Name:
Parcel ID#: Address:
Dat, Person S 9ken; To - Com
vments / Aetion to be Taker}., __-._:. _._-_..__ _ . _ . initials Time
ZD- s . _ \ a ave ' Q 1 1. to vire k