HomeMy WebLinkAboutpitkin.eh.264321301005 (2006)PITKIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM 0405 Castle Creek Road, Suite 10, Aspen Colorado 81611 Phone (970) 920-5070 Fax (970) 920-5077 De_ Name of OWNER �Q ti- ' e Owner's Mailing Address , f A0,8. 300 State, Business Phone: JV 5 -9 Home Phone: 7219 % 74r.6& E-mail Address: 4?SQe4A-e4 & Io S. Al Coxes Primary Contact Person (all communication regarding this permit will go through this person) �- Name ' . V Company Contact Mailing Address a' C\X -7 Oq - 1 q t City, State, Zip Business Phone Cell Phone : Fax E-mail Address: Parcel ID # (available from assessor's office at 920-5160 or at www.pitkinassessor.orq) - L - - Z2 Building Permit # (if available) /Y !j Street address of property Legal Description: Lot ,Block Filing _ ,Subdivision Xrk s /4 clee j�-- Size of lot: .'. 2 3 acres. Type of proposed structure: W,0$g`AA at0-S/yt c, lig A,? 'A f� Total square feet of house -7 `O a # of bedrooms (potential) in house Caretaker Unit: Attached ( ) Detached ( *---) y Total area(sq. ft.) of caretaker unit 1,P 49 0 # of bedrooms (potential) in caretaker unit / Permit is for: New Home ( Repair due to failure ( ) Remodel/Addition ( ) Emergency use ( ) Water: Private well ( ) Spring ( ) Stream ( ) Community/Public Water System (t.)' If community system: Name of system Sr 14 s A C p r c A The fee for a ISDS application is $600 for a permit that takes 6 hours or less for the department to approve. If approval takes longer than 6 hours, a rate of $100 per hour will be charged. The maximum fee is $1000. The basic fee of $600 is due at the time of application. The remainder, if any, will be due in two stages: first, at the time of issuance of the ISDS permit; second, before final approval of the ISDS permit. Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information is true and accurate and that I have provided true and accurate information on locations of all existing and proposed wells, contour intervals, buildings, property lines, ditches, slopes, waterlines, springs, suction or irrigation lines, drinking water cisterns, drain tiles, irrigation ditches, lakes, water courses, streams, floodplains, dry gulches, and existing septic systems. I hereby certify that any such features not shown on attached site map are not present. Issuance of the permit does not imply the approval of any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all approvals and permits have been obtained. The Pitkin County Environmental Health Department, Pitkin County and employees of these agencies will be held harmless should the individual sewage disposal system fail or malfunction. The permit to construct is issued on information submitted by the applicant or his/her representatives. owner assumes full responsibility in case of failure of the system. Signature of applicAnt% Date - —eow /.41.6 Received by l� ` ^ Receipt # J s Date G:\isds\isds applic\isdsapp rev072904.doc 6 (Z t ' _- a o• Pitkin County Environmental Health Department Contact Log Sheetc f Name: �- Parcel ID#: Address: D to Person Spoken To Comments /_Action to be Taken _ Initials Time 4 RE M 111 EMS figMWRIOTMORRIMMM MIMMINDMIN ME ®� f- �� Brush Creek Metropolitan District 500 Juniper Hill Road, Aspen, CO 81611 • (970) 923-9209 9/18/06 Mr. Raines, The BCMD was formed for the purpose of providing water to Brush Creek Village. The Raines Lot (Filing 2, Block 1, Lot 6) on Upper Ranch Road has the right "hook-up" to the system. The usage will be subject to the same fees and usage guidelines as every other district member. Kevin McClure, manager VW+'' Carla Ostber From: tpetzl@comcast.net Sent: Wednesday, September 13, 2006 7:47 AM To: Carla Ostberg Cc: e3rddegree@comcast.net Subject: Doug Raines test pit ready Test pit ready for viewing. Lot 6, Upper Ranch Road (no address yet) Directions: Brush Creek Road to Medicine Bow. Take first right on Upper Ranch Road. Drive to top and look for two stakes with pink flags (Just past the new Larson Residence on the end of the ridge). The stakes iare the entrance to the drive, go down drive to pit with PVC. Contact: Doug Raines 970-920-7856 Notes: In our original OWS design we used HP soils data. I decided to do a test pit to confirm. I will do an engineered letter describing soil conditions to accompany design. Timothy R. Petz, P.G. Onsite Wastewater Systems 970-618-5033 Glenwood Springs 303-908-7823 Golden 1 61I(No� E V� 0 PO Box 2844 L S P t i C Glenwood Springs, CO 81602 SERY�C M Ph 970-618-5033 l fax 303-216-2796 March 3 I st 2008 Doug Raines PMB 256 300 Puppy Smith Street Aspen CO 81611 Installation Observations Lot 6, Brush Creek Village Upper Ranch Road, Permit #06079 Pitkin County, Colorado Doug, Project No. 1245 ALL SERVICE septic, LLC performed an installation observation on August 15th, August 29th and October I Oth 2007 for the subject property. The installation included a 1500 -gallon, single -compartment co tic tank, followed by a 1000 -gallon, two-compartment septic tank with the additionof efflue on the outlet, followed by 5 gravelless trenches. Each trench consisted of 24 chambers per c for a total of 120 chambers, equaling 1185 SF of infiltrative area. Effluent will be distributed with a concrete distribution box with a baffle. The OWS was installed according to specifications. This observation is not a guarantee of workmanship and/or parts and materials. ALL SERVICE septic, LLC should be notified if changes are made to the OWS. LIMITS: The observation was based on information submitted and our site visit. If conditions are different from conditions described in this letter, ALL SERVICE septic, LLC should be notified. All additional OWS construction must be according to the county regulations. The installer should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. Sincerely, ALL SE -1'7— E eptic, LLC Timothy . Petz 2 copies sent Copy sent to Pitkin County Health Dept. gpp0 LICFN ie ' 38662 N; Richard H. r P.E. MO Septic tanks Gravelless chambers and observation pipes Pro No 1245 �� z 9 0 OWS AS -BUILT O O 4" SEW LINE WITH CLE OUT O \ C D OBSERVATION/VENT PIPES (TYP.) AT BOTH ENDS OF TRENCH CE 165 SF OF INFILTRATIVE AREA IN 5 GRAVELLESS CHAMBER -TRENCHES. EACH TRENCH HAS ONE ROW OF 24 INFILTRATOR(R) QUICK4(TM) CHAMBERS FOR A TOTAL OF 120 CHAMBERS. MAIN ICK4(TM) END CAPS " PVC HEADERS 1000 -GALLON, TWO-COMPARTMENT, CONCRETE SEPTIC TANK WITH AN EFFLUENT FILTER IN THE SECOND COMPARTMENT 1500 -GALLON, SINGLE -COMPARTMENT, CONCRETE SEPTIC TANK 4" SFWER LINE WITH LEANOUTS SCALE V,=30' NORTH LOT 6, BLK I, FIL 2, BRUSH CREEK VILLAGE ALL PRO. N0. 1245 PITKIN COUNTY, COLORADO SERVICE SEPTIC, LLC RAINES RESIDENCE 970-618-5033 FIGURE ISDS DESIGN CALCULATIONS - for Pitkin Owner's Name Parcel ID # House Size (sq. ft.) x (75 gpd, 100 gpd, or 130 gpd) 100 Number of Bedrooms in Main House &OM Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House Number of Bedrooms in Detached Caretaker unit Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit (If the caretaker unit is ATTACHED, treat as if part of main house.) Average Daily Waste Flow 1000 State Review Required? no Perc Rate _ (T) Design Flow (Q) = # potential bedrooms X 2 people/bedroom X gpd X 1.75 Q= 1750 Minimum tank capacity 2187.5 gallons Absorption Area (=Q/5 X SQRT perc rate) A = 2,322 sq. ft. of absorption area required 150 gravelless chamber units without reduction # of Perc Holes Required: 3 QUICK 4 9_8 A = 1160.8187 sq.ft. with 50% reductionTRENCHES 118 gravelless chamber units with reduction STANDARD A = 1160.8187 sq.ft. with 50% reductionTRENCHES 75 gravelless chamber units with reduction EQ 36 73 EQ36 units in TRENCHES QUICK4-EQ36 1161 150 SETBACK FROM WELL # of feet = 160 SETBACK FROM POND, STREAM OR IRRIGATION DITCH # of feet = 110 SETBACK FROM DRY GULCH # of feet = 85 DICK 4 9.2 1625.1461 sq ft 30% reduction BED 177 chamber units with reduc. 1625.1461 sq ft 30% reduction BED 105 chamber units with reduc. 130 EQ36 units in a BED 1625 254 PO Box 2844 Glenwood Springs, CO 81602 Ph 970-618-5033 fax 303-216-2796 September 7, 2006 Doug Raines PMB 256 300 Puppy Smith Street Aspen, Colorado 81611 C S lvE� FP P1rk1,y , 2 6 2006' 86gir8&,VA Y rvv�k N URk RFSOuR FS Onsite Wastewater System Design, Proposed Residence and ADU Lot 6, Brush Creek Pitkin County, Colorado Mr. Raines, Project No. 1245 ALL SERVICE septic, LLC has performed a subsurface investigation and prepared an onsite wastewater system (OWS) design for the subject residence. A subsurface investigation was performed by H.P. Geotech on August 18, 2000 and presented in a report under Job No. 100 623.This report has been included as Appendix A. The percolation test was performed on September 5, 2006. The property is located in near Aspen, Colorado, in an area where OWS are necessary. This letter is to be used in conjunction with plans provided. SITE CONDITIONS A four-bedroom residence and a one -bedroom ADU with a total living area less than 6000 ft2 are proposed at the site as indicated on plans provided. The slope at the proposed drain field area is approximately 25% to 30% to the northeast. Vegetation consists of a full cover of native grasses with moderate scrub oak and serviceberry. Water is provided to the site by the local water district. SUBSURFACE The subsurface was investigated by drilling an exploratory boring near the proposed drain field location as shown on the attached plans. Subsurface conditions reported consisted of sandy, clay fill to 1 foot, underlain by sandy clay to 21 feet, underlain by weathered claystone bedrock to 25 feet, underlain by claystone bedrock to the maximum depth explored of 31 feet. Groundwater was not encountered. Subsurface conditions can be verified by nearby road cuts. Pitkin County Environmental Health Department may require a test pit prior to installation. Five percolation holes were dug. Percolation rates ranged from 32 to 53 minutes per inch (MPI) with an average rate of 44 MPI. DESIGN SPECIFICATIONS The OWS design is based on 5 bedrooms, an average sewage load of 1000 GPD, and a percolation rate of 44 MPI. The installation must include a 1500 -gallon, single -compartment, concrete septic tank with an effluent filter on the outlet followed by a 1000 -gallon, two-compartment, concrete septic tank OWS Design Project No. 1245, 9/7/06 Page 2 J with an effluent pump in the second compartment. Tank alternatives may be considered. A pump with a total flow rate of 20 GPM and a total dynamic head of 17.7 feet is required. Pump specification have been included. Five gravelless chamber -trenches must be"stalled as indicated on plans provided. Five rows of 24 `Quick 4' chambers, for a total of 120 chambers and 1176 ft2 of infiltrative area are required. The drain field may be reconfigured to preserve vegetation and to conform to topography. ALL SERVICE septic, LLC should be contacted to make any necessary adjustments to the drain field. A concrete distribution box with a baffle should be used to distribute effluent. Construction must be according to the county ISDS regulations, the septic permit provided by Pitkin County Environmental Health Department, and this design. OPERATION INFORMATION AND MAINTENANCE The surface of the drain field should be seeded upon completion. Vegetation is an important factor in drain field performance. Geo -fabrics or plastics should not be used over the drain field. Livestock should not graze on the drain field. Plumbing fixtures should be checked to ensure that no additional water is being discharged to OWS. For Example, a running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a drain field. The homeowner should pump the septic tank every two years and clean the effluent filter as needed. Garbage disposal use should be minimized, and non -biodegradable materials should not be placed into the OWS. Grease should not be placed in household drains. Loading from a water softener should not be discharged into the OWS. No hazardous wastes should be directed into the OWS. Mechanical room drains should not discharge into the OWS. The OWS is engineered for domestic waste only. If easements have been encroached upon, it is the homeowner's responsibility to understand potential issues. We can be contacted for information regarding easements. ADDITIONAL CONSTRUCTION NOTES If design includes a pump, air release valves and weep holes should be installed to allow pump lines to drain to minimize risk of freezing. Excavation equipment must not drive in excavation of drain field due to the potential to compact soil. Extensions should be placed on all septic tank components to allow access to them from existing grade. Precast concrete tanks and distribution boxes should be used, unless plastic or fiberglass is required. Septic tank risers should extend to grade. Access to all tank compartments and distribution devices is optimal. INSTALLATION OBSERVATIONS ALL SERVICE septic, LLC, and the county must view the OWS during construction. The OWS observation should be performed before backfill, after placement of chambers and distribution pipes. Septic tanks, distribution devices, pumps, dosing siphons, and other plumbing, as applicable, must also be observed. ALL SERVICE septic, LLC should be notified 48 hours in advance to observe the installation. LIMITS: The design is based on information submitted. If soil conditions encountered are different from conditions described in report, ALL SERVICE septic, LLC should be notified. All OWS construction must be according to the county regulations. Requirements not specified in this report must follow OWS Design Project No. 1245, 9/7/06 Page 3 county regulations. The installer should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. Please call with questions. Sincerely, ALL SERVICE septic, LLC Timothy R. Petz 3 copies Reviewed By; Richard PITKIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT Percolation Test and Soils Data Form - TABLE 1 - PROJECT 1245 PROFILE BORING Date of I est: uyiub/ue 0 - 1' Fill, clay, sandy, stiff, moist, dark brown 1'- 21' Clay, sandy, very stiff to hard, slightly moist, brown 21'- 25' Weatehered claystone bedrock, medium hard to hard, slightly moist, brownish gray 25'- 31' Claystone bedrock, hard to very hard, slightly moist, dark gray No Groundwater was Encountered Hole No. Hole Depth (in.) Interval (min.) Measurement at Start of Interval (in.) Measurement at End of Interval (in.) Change (in.) Percolation Rate (min./in.) MPI 1 26 20 2.50 5.00 2.50 20 2.13 3.63 1.50 20 3.63 4.50 0.88 20 2.50 3.63 1.13 20 3.63 4.38 0.75 20 4.38 4.88 0.50 40 2 22 20 1.63 4.38 2.75 20 4.38 5.38 1.00 20 2.00 3.38 1.38 20 3.38 4.13 0.75 20 4.13 4.63 0.50 20 4.63 5.00 0.38 53 3 20 20 1.88 5.00 3.13 20 5.00 6.50 1.50 20 2.25 4.13 1.88 20 4.13 5.13 1.00 20 5.13 5.63 0.50 20 5.63 6.13 0.50 40 AVG = 44 MPI PITKIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT Percolation Test and Soils Data Form - TABLE 1 CONT.- PROJECT 1072 PROFILE BORING Date of Test: 09/05/06 0 - 1' Fill, clay, sandy, stiff, moist, dark brown 1'- 21' Clay, sandy, very stiff to hard, slightly moist, brown 21'- 25' Weatehered claystone bedrock, medium hard to hard, slightly moist, brownish gray 25'- 31' Claystone bedrock, hard to very hard, slightly moist, dark gray No Groundwater was Encountered Hole No. Hole Depth (in.) Interval (min.) Measurement at Start of Interval (in.) Measurement at End of Interval (in.) Change (in.) Percolation Rate (min./in.) MPI 4 25 20 2.38 6.63 4.25 20 2.50 5.25 2.75 20 5.25 6.75 1.50 20 1.75 3.50 1.75 20 3.50 4.50 1.00 20 4.50 5.13 0.63 32 5 25 20 2.50 4.88 2.38 20 4.88 5.88 1.00 20 2.13 3.25 1.13 20 3.25 3.88 0.63 20 3.88 4.25 0.38 53 20 4.25 4.75 0.50 AVG = 44 MPI W E C. m CR 0 O O N O O O ti U > Er N J Er 00 Q z i 4" �_ ccW 41 0 Q = m O E m V) m d.+ V 4) N N N L. a 1 O Z m L _O AV W 7@ co Q E a O F V V co W) N O M M N N N •'- �- 3ai `(Hal) PeeH o!weuAa iewi U) N N E L L L N m C C C N Z r Z m a' O c6 C v) -O W N tNA L N m O T O C LL Z j5 O J E O O co a n y N LL C i YO N O N N U cm c n rn o a L �6 N 0 N Q m N Q m C E @ to CL CL c C. m CR 0 O O N O O O ti U lij O > J O U N W CC S Qi -C O o LL�"i O F V V co W) N O M M N N N •'- �- 3ai `(Hal) PeeH o!weuAa iewi U) N N E L L L N m C C C N Z r Z m a' O c6 C v) -O W N tNA L N m O T O C LL Z j5 O J E O O co a n y N LL C i YO N O N N U cm c n rn o a L �6 N 0 N Q m N Q m C E @ to CL CL c C. m CR O P O O O O O N O O O ti C; I.: N T > y > 4. 0 _ O!OA 3 J +O. -C O o Q N N _ a) O c o L LL O O r 3I N Q O 7 N r `m l0 H m N to41 = CD O 0 = _ R v a -- R= U U) o t 0 7 M L d N W --j Of 0a lic's Cl) a O F V V co W) N O M M N N N •'- �- 3ai `(Hal) PeeH o!weuAa iewi U) N N E L L L N m C C C N Z r Z m a' O c6 C v) -O W N tNA L N m O T O C LL Z j5 O J E O O co a n y N LL C i YO N O N N U cm c n rn o a L �6 N 0 N Q m N Q m C E @ to CL CL c 0 C) O C. m CR O P O O O O O N O O O ti C; I.: N T > y > 4. 0 _ O!OA 3 J +O. -C O o _ a) O c o L LL O O r 3I N Q O J l0 H m N to41 = CD O 0 = _ R v v m R= U 0 C) O Appendix A Hepworth-Pawlak Geotechnical, Inc. Subsurface Study for Foundation Design Proposed Residence Lot 6, Filing 1, Brush Creek Village Upper Ranch Road Pitkin County, Colorado Job No. 100 623 October 31, 2000 Aug -31 OD 09:47a Doug Raines./Karen Gable 97052078566 p.2 r Hepworth pa�efal� Ge•3tedI*ai, Inc. �iL'tt County Road Colorado 81641 Gienwgod 8p�� phogw 97&&45-7988 F= M945-8454 $p9c6@Fpgeotec'6c0nz SLW RFACE 9rUIDY FOR. FouNDATION DFMG-N PROPOSED RESIDENCE LOT 6, BLOCK 1, FILING 2, BRUSH CREEK 'VU'LAGE UPPER RANCH ROA�D� PITEIN COUN FM COLORADO JOB NO. 100 623 OCTOBER 31, 2004 • Mla -% � • ROGER PEACOCK P.O. BOX 2.513 ASPEN, COLORADO 91612 Aug 31 OG 09:49a Doug Raines/Karen Gable 9709207956 p_7 SUBSUJRFACE CONDITIONS Graphic logs of the subsurface conditions encownered at the site are shown on Fig. 2_ Below about 1 foot of fill mater: als for constmtdion of the driveway, the subsoils consist of vera- stiff to hard s2ndy clay. At a depth of about 22 to 25 feet, ciaystone bedrock was enmuntered. The upper 3;6 to 4 feet of the bedrock was weathered. Drilling refusal was encountered in the claystone at depths of 31 and 33 feet due to the hardness and possible cemented conditim o, the bedrock. The soils eaco-antered in the borings are similar to the soils encountered at other nearby lots. The stiff to hard clays can possess an expansion. potential when wetted. Laboratory testing performed on samples obtained during the field explo. ation included natural moistuze content and density, Atxerberg limits and finer than sand size gradation analyses. Swell -consolidation testing was performed on relatively undisturbed drive samples of the clay subsoils. The swell -consolidation test rmilts, presented -on Figs. 4 through 6, indicate low compressibility under relatively light surcharge loading and a high expansion potential when wetted under a constant light surcharge. Swelling pressures between 15,000 psf and 30,000 psf were indicated. The very bard c12ystone bedrock is not expected to be expansive. The laboratory tag is summarized in Table 1. No free water was encountered in the borings at the time of drilling or when checked on October 31, 2 W- The subsoils were slightly moist to moist. FOUNDATION BEARILNG CONDITIONS The clay subsoils encountered at the site are highly expansive. Shallow foundations p1,a;ced on the expwnsive soils similar to those encountered at this site can expenence movement causing structural distress if the clay soil is subjected to changes in moisture Content_ A drilled pier foundation can be used to penetrate the eiTansive materials to plaev tate bottom of the piers in a zone of relatively stable moisture conditions and make it palm-ble to load the pies sufficiently to resist uplift movements. H -P GEOTECH Aug 3f 0S 09.59a Doug Raines/Karan Gable 9709207956 p.17 Aug 31 06 49;59a Doug Raines. -'Karen Gable 9709207856 p. 19 155 155 Not= Wmc#m csf --YM is is shown ca Fq. 3. PA1M-AK LOU'S OF EXPLMATORY BORINGS F9 2 14+D 623 GEOTECHMCAL INC. 80MG 1 BORMG 2 ELEV.188' ELEV_ = 1a$ 190 190 IM 185 4162 33%2 1sc3 180 1tY-0 4 10 50/9 LL1' 1 FI -l4 W=I" �/5 t75 i dho 175 102 X13' sots i ! o i a ssJ� 170 17D o sola 165 1G5 �ipf6 wcxts.3 !]O�tT9 5o/s 160 16[1 155 155 Not= Wmc#m csf --YM is is shown ca Fq. 3. PA1M-AK LOU'S OF EXPLMATORY BORINGS F9 2 14+D 623 GEOTECHMCAL INC. gsur_ 31 GG 09e 5sa LEGEND: wswmnm w� Doug RaineslKaren Gable 9709207956 P.19 VN MAN—PLACED FlU-; sandy dark t+ lay, staff. moist, da�sown. CLAY (CL). sw.dy. very sUffi to hard, 15'19htly moist, brown, medium plasticity. iVEA11iERED CLAYSTONE BEDROM medium hard to hard, slightly moist, brownishgro34 CLAYSTONE BEDROCK: hard to very hard. slightly moist, dark grqy. Mancos Shale_ Relatively undisturbed drive sample, 2—inch LD. California finer sample. 3i3 12 Drive samPle blown count: indicates that 38 blows o` a 140 -pouted hammer iO3Nng 30 inches were required to drive the C.diforrda sampilu 12 inches. TPractical rig refusal. NOTES. 1. Exploratory borings were drilled on ALgust 18. 2000 with a 4—hch diameter ccrtinuous flight power anger. 2. Locations of expknAor'y borings were measured apprc*Cxnately by taping from features shown on the site plan provided - 3. Elevations of exploratory borings were obtained by interpdation between contours on the site plan provided. 4. The exploratory boring locations and elevations should be considered accurate orgy to the degree irnpliecd by the method used 5. The rives between materials shown an the =plorotory baling logs represent the oppreximote boundaries betWeen materiel types and transitions may be graduaL 6. No free water was encountered in the borings at the time orf drilling or when checked on October 31. 2000. Fluctuation in rater level may occur with time. 7. Loboratary Testing Rescfts: we — wa=Ler Content ( x ) DD = Dry Density ( pcf ) —200 — Percent passing No. 200 sieve- " = Liquid Limit ( X ) pi = Plasticity Index ( X ) 100 623 1 HEPWORT i — PAWLAK LEGEND AND NOTESI Fig. 3 GEO-MCHNICAL, INC_ 0 cmi� C N C O Z ZO O o�rn ;o I 0 0 .;�, �. � 'p .v. ��, .... ',�1 ' •M�.'1 f ,_,` '.. �..+P S '` u { t ' "?? �a; �� �+'' x; � . Jr• - . - , ,,. � .„v 14 U-7 #1 i TANK SPECIFICATIONS Septic Tank Configuration 0 0 OrencoSystems® CAPACITY REQUIRED= q X 1.75 X (30 HOURS/24 HOURS) _ 1500 -GALLON, SINGLE -COMPARTMENT, CONCRETE SEPTIC TANK WITH AN EFFLUENT FILTER FOLLOWED BY 1000 -GALLON, Incorporated 2188 GALLONS TWO-COMPARTMENT, CONCRETE SEPTIC TANK WITH AN EFFLUENT PUMP 814 AIRWAY AVENUE SUTHERLIN, OREGON 97479-9012 TELEPHONE: REQUIRED TANKS = 1500 -GALLON, SINGLE - (541) 459-4449 e FACSIMILE: COMPARTMENT, CONCRETE SEPTIC TANK WITH AN Splice Box w/Cord Grips (541) 459-2884 EFFLUENT FILTER ON THE OUTLET FOLLOWED BY e PC Splice Box 1000 -GALLON, TWO-COMPARTMENT, CONCRETE SEPTIC Fiberglass GasLeel Bolt Dd with wdh Gard Grips TANK WITH AN EFFLUENT PUMP IN THE SECOND Stainless Steel Bogs Fiberglass Gasketed Lid with Slope Ground PVC Riser with Grommets Stainless Steel Bolts / p O COMPARTMENT. Awa, Fr¢m Ri -r / (bond to tank adapter with Slope Ground -- !/ recommended adhesive) Away from Riser PVC Riser with Grommet(s) _,. (bond to tank adopter with Tank Ado ter Conduit to �z /—Filter Cartridge Handle ,_ recommended adhesive) Alarm Panel I �(Rald cut to desired height) �—Discharge Assembly ALTERNATIVE TANK OPTIONS WILL BE CONSIDERED cast or belted Conduit to i' Flexible Hose Conduit Seal ///''' / ( )�. / Tank Adapter (cast or bolted) Control Pane �-ENluent Discharge APPROX. Conduit SoGI L. -at Tca - ..". I Vent Orifice ( Tank Adapter (cast or bolted) __quid Level ' s, k� Level Control SCALE o Llautd Level , g Float Assembly Modulating Discharge Orifices �j II 201 B 1/8" Weep Hole Vault Inlet Ports Clear Zone Opening In the Baffle is an T acceptable alematroe to PVC t NORTH H Effluent Pump High Leval _ Alarm Float `—' Concrete Block Filter Cartridge Fr0400 Sodas Biotube Effluent Filter Foreign 4,439, en & 5,492,635 Foreign stents Periling 0 1997, Orenco Systems, Inc. TYPICAL PLAN VIEW - N.T.S. r 2" PUMP CONCRETE DISTRIBUTION BOX WITH BAFFLE OBSERVATION/VENT PIPES (TYP.) LINE OBSERVATION/VENT PIPES (TYP-) 0 0 0 1176 SF OF INFILTRATIVE AREA IN 5 GRAVELLESS CHAMBER -TRENCHES. INFILTRATOR(R) QUICK4(TM) 6' MIN. QUICK4(TM) END CAPS ° `ti EACH TRENCH MUST HAVE ONE ROW OF 24 INFILTRATOR(R) QUICK4(TM) CHAMBERS, 3' x 4' `� CHAMBERS FOR A TOTAL OF 120 CHAMBERS. TRENCHES MAY BE MODIFIED TO CONFOR11 TO TOPOGRAPHY AND TO PRESERVE VEGETATION. 0 I' 4" I' 4" —' s- T0 0 QUICK4(TM) END CAPS 96, 0 3 4" PVC HEADERS 0"1- 4" PVC HEADERS TO ADDITIONAL TRENCHES O l -' 2 PUMP LINE TYPICAL CROSS-SECTION - N.T.S. TOTAL - FIVE TRENCHES 52" 12II 4 " 1000 -GALLON, TWO-COMPARTMENT, CONCRETE SEPTIC TANK 4" SDR 35 OBSERVATION/ (EFFECTIVE LENGTH) CONCRETE � WITH AN EFFLUENT PUMP IN THE SECOND COMPARTMENT VENT PIPE WITH CAP 34 1500 -GALLON, SINGLE -COMPARTMENT, CONCRETE SEPTICS e DISTRIBUTION SECTION VIEW �°� TANK WITH AN EFFLUENT FILTER ON THE OUTLET BOX WITH BACKFILL BAFFLE `� O R SIDE VIEW O 3' AX. 16" PROPOSED SLOP -BEDROOM ADU �` 6' MIN. DL_ FOR `\ 4" SEXIER LINES 2 MIN. PROPOSED GARAGE \ WITH CLEANOUTS INFILTRATOR(R) 12" SCARIFY SURFACE QUICK4(TM) CHAMBERS, 3' x 4' INFILTRATOR(R) PROPOSED 4 -BEDROOM EXTENT OF EXCAVATION 34 QUICK4(TM) CUT SHEET RESIDENCE ` CALCULATIONS: NOTES: bio ` FIVE -BEDROOM SINGLE-FAMILY RESIDENCE + ADU <6000SF CHAMBER -TRENCHES MAY BE ANGLED AND/OR RE -ARRANGED TO FIT N GALLONS PER BEDROOM = 200 TOPOGRAPHY AND REDUCE DISTURBANCE OF NATIVE VEGETATION. AVERAGE SEWAGE LOADING = Q = 1000 GPD PEAK SEWAGE LOADING = Q = 1750 GALLONS THE SLOPE AT THE PROPOSED DRAIN FIELD IS APPROXIMATELY 25% TO 30% PERCOLATION RATE = T = 44 MPI TO THE NORTHEAST. VEGETATION CONSISTS OF A FULL COVER OF NATIVE \ \` GRASSES WITH MODERATE SCRUB OAK AND SERVICEBERRY. y : 1 AREA= Q x SART T / 5 = 23.22 SF 50% REDUCTION FOR CHAMBER -TRENCHES 1161 SF LIMITATIONS -THESE PLANS MUST BE USED IN CONJUNCTION WITH LETTER O AND SOILS DATA FORM PROVIDED. THE DESIGN IS BASED UPON INFORMATION SUBMITTED. IF SOIL CONDITIONS ENCOUNTERED ARE DIFFERENT FROM ncEIVEDTRENCH SPECIFICATIONS: CONDITIONS DESCRIBED IN REPORT, ALL SERVICE SEPTIC L.L.C. SHOULD BE 40 NOTIFIED. ALL OWS CONSTRUCTION MUST BE ACCORDING TO COUNTY SEP 2 6 2006 _ PROPOSED RIVEWAY WIDTH OF TRENCHES = 3 FEET, I CHAMBER REGULATIONS. THE INSTALLER SHOULD HAVE DEMONSTRATED KNOWLEDGE PITHEAL &NA YENV'ior"IMENTAL LENGTH OF TRENCHES 96 FEET, 24 CHAMBERS OF THE REQUIREMENTS AND REGULATIONS OF THE COUNTY IN WHICH THEY HEALTH NATURALRESOURCES EXISTING DRIVEWAY NUMBER OF TRENCHES = 5 ARE WORKING. THE COUNTY AND ALL SERVICE SEPTIC L.L.C. MUST VIEW RETAINING WALLS TOTAL NUMBER OF CHAMBERS - 120 INSTALLATION TOTAL AREA PROPOSED = 1176 SF ALL SERVICE septic, LLC LOT 6, BRUSH CREEK PROJECT No. 1245 PO BOX 2844 p P I TK I N COUNTY COLORADO ONSITE WAS EWA ER SYSTEM DESIGNe-11 GLENWOOD SPRINGS, CO 81602 -00 970-618-5033 RAINES RESIDENCE F] I 7 LOT 5-0,9 3 ".-Vow _T10 REBAR ILA 17 X. I I 11� V. _T5A.CK t :rA it Z t-42.1 kk A W C) X. C-) it k ej lk L CIL Uri] f L 6 I 2.23 ac+ l I La I J I LDI.' ilk 3 ELI ANGLE TO PROPERTY LINE OPE CONTINUES AT SAM V��M. t �7 J 9 R. r E lJ I i , � I , i f A t M. IF. f r. wI Jj 4k i ,i C _ .0i 0 Ir fii WO* J -j 21 1-0 5 'AR. POLIND- N - 0 5 RES AR P (2w ILLEG-7118LE D 00' S S U fv4 E D E, EIVATION= t2uO A T T0, U, Fff'RE HYDRA,'NT lI \N - E, COF, SEC ?R -1x —v T91S, R8 -5W NOT- H; ! According tG C{ law yow m-ust. commence any legai action based: upon his. survey any d0ect In twit def Iwad-ith ';n three yews- -d-ter you scover such O. be nced ore I'm no- ever-tt rna 6 Wig pok-Any n this stiveycommem -ect . o than tery years `rirany t om - the date a tht tettv cobw sfiown. hemw. R V E CD RAINES 1041 HAZARD REVIEW SITE PLAN.. LOT N�, �HR-,,-ADDLYS IANGENT CH0FD I KAKI NG EST RE C1 31.091 2 00, 0 fj 15,58 31, 0 6 S38-12"4 .5 8�5-4`24-q 1 08t: --4`53z`30`Wj 88 * 0 3 N11 RAINES 1041 HAZARD REVIEW SITE PLAN.. LOT 6, FILING 2 COZY PONT RAN( -'H Lil{U.l.`ti U1051M RECF-1 jjf 1��Jjj 490030 page : I Of I �11,111114.. 1 10/21/2003 10:32A '1A DAVIS PITKIN COUNTY CO R 11-09 It 0 0,00 T tz I Rows - BASIS OF ELEVATIO?4- AN ASSUMED ELEVATION' Of 200.00 AT THE TOP Of FIRE HYDRANT AND SHOWN HEREON. - THE CONTOUR LEVEL IS TWO (2) FEET. BA$W OF SEAAD46� A CM"L� Of S,000 42'33'T BtTW0eK A FOW NO 5. RWAR AOO Yk L S'431,944 AT THE S-- W.- PROPtOY COMf* AND A NO. 5 MAP, AND -404� CAP ULLEGME) AT THt SOU TH1 PROP. CORNER LEGAL DESCRIPTION' LOT 6, FILMG 27 RRUSN' C- REEK SUBDIVISM AS SET FORTH IN THE PLAt Atk�Eb 3UNE 2 1, 1966 IN PLAT BOOK 3 AT PAGE S. SECTION 21, TOWNSHIP 9 SOUTH, RANGE 85 WEST OF THE 6TH:. P.M. IN n4E COUNTY OF PIMN, StAn Of COLORADO-. SLOPE COVEikED WITH BRUSH. Legend I P41BI ATE S FOUNIJ KEINUMEMIT AS D-E'SCRIBE& v FEN�-E LINE GVERKE"D UTILITY LIML POW EiR PCH E TELEPHONE RISER zrR.-- HYDRANT APEA T - SIHADED INDICATED SLOPE BETWEEN 9-3107- ALL OTHER AREAS GREATER THA SLOPE, 1041 HAZARDREVIEW SEP 2 6 200 PITK//v COU 6 HEALTHS 1"Ll"HUNiWE NATURAL RESOURCES URCES APPU E -1, AW - I '' CQ.tJ.WTY ..�;.-Af4.TA-1�-KN-O.W�-M-CESTHA.-TI4./Sfi:EH,AS:BEE.'N.-14FO.�.M_.P,BYPff-K-.N kko fhkz�:AiktM: �"W MOK AOW Of THE ME: - 4' 714E PROP80Y, AW MPROVW...'' T THE PROVISIONS WAY ASSO' RE ' #R-tt OR IMPLY THAT AR%-S:0u.- Tv. -S -I Of C-4&ONA -HA4 AREA$ WILL Sf 0 - Fp,0pj HAZARDS, Ok TWT A000b146 1Mft1GATIbK NiEASURES- WILL GOA�THE SAFM Of ANY PROPERTY. THIS 1044 MZA": REVIEW STM KW HAS B A EVIE' WED AND APPROVED SY THE SOARD Of POM COWY COMMIS`510- SUS*fit TO Tfit MM AND, C AS' ACC FOR RECQRMG THIS 10.41 HAZARD REVIEW SITE PLAN HAS. BEEN A"PTM FOR FILING IN Th - - -00-; t -- - Y OF E. U.0 Of PIT TH�0MCEOFT44ECLMARPRMORM STATE -0-F COLOR00.). AT"wAup-cu - K., M. TM. S.. - AS INPLATSWK ATPAGE em DATE SURVEYM. 12/26/9.9, 05/06/03 DATE DRAFTED: 05/07/03 REVISED: <xf� I&A, . Z-3 - DATA FILE NAME!. 0305127 DRAWN BY, R.L.. 4