HomeMy WebLinkAboutpitkin.eh.264321303004 (1988)_CHG OF SEPTIC O'SHIPr
PARCEL ID.,74Y3 a2/3 -03 - 001
CHANGE OF OWNERSHIP/SEPTIC RECORDS
NEW OWNER:
ADDRESS:
LEGAL DESCRIPTION:
PREVIOUS OWNER:
ASPEN/PITKIN AVIRONMENTAL HEALTH DEPARTMENT
ISDS DESIGN REQUIREMENTS
DEPARTMENT USE ONLY
Permit #
Name E: L -'b M ri k/ Parcel ID #
House SIZE 3,000 (75 gpd, 100 gpd, or 130 gpd) 100
Number of Tedrooms, Lofts, Offices, Similar Rooms, Main House 5
Number of Bedrooms, Lofts, Offices, Similar Rooms, Caretaker unit
Average Daily Waste Flow 750 # bedrooms X 2 people/br X 75
State Review Required? no
Perc Rate 9 (T)
Design Flo w (Q) _ # bedrooms X 2 people/bedroom X gpd X 1.75
Q= 1750
Absorption Area (A Q/5 X SQRT)
A = 1050 sq. ft. of absorption area required
E38 infiltrator units without reduction
or 350 lineal feet of 3' wide trenches
A maximum 30% reduction is allowed for use of deep gravel or gravelless chambered system.
735 sq.ft. with reduction
47 infiltrator units with reduction
245 lineal feet of infiltration units in 3' wide trenches
Type of system: []Absorption trenches []Absorption bed [] Gravelless chambers
[]Dry well []Seepage Pit []Pumping Chamber
Is an Engineer -Designed System required? no
yes reason:
Minimum tank capacity 2187.5 gallons
SETBACK FROM WELL
# of feet = 160
Remember: 8 feet of additional distance for each 100 gallons/day of design flow over 1,000 gallons/day
should be added unless an RPE can verify that it is not necessary to prevent contamination.
APPROVED FOR ISSUE BY:
SYSTEM INSTALLED BY:
DATE OF FINAL INSPECTION REQUEST:
FINAL INSPECTION BY:
Printed on Recycled Paper
DATE:
DATE: