Loading...
HomeMy WebLinkAboutpitkin.eh.264321304003 (1994)ASPEN/PITKIN ENVIRONMENTAL HEALTH DEPARTMCNT APPLICA(TIONN�FOR AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM (ISDS) PERMIT f\1ame of OWNER H� l/Lv0 /l.� I / )fir C Bus. Phone # 22 3 Mailing Address or 101/17 4ZC-,1 `'� o/�1 Z Home Phone # Name of AGENT S7 /-TD Bus. Phone # Mailing Address CJS 6961 S�,J�UJM�SS' ('D 7w Home Phone # , Copy of Permit to be Sent to: jl� IV Al E PERMIT IS FOR: X NEW INSTALLATION, O REPAIR, O ALTERATION NOT DUE TO FAILURE, or O EMERGENCY USE. for permit # CTPPFT Anr)RFSS of Prooertv: 7Z sn N1 LEGAL DESCRIPTION of Property: lot '3, block l� , filing L, and subdiv. (-��EEKx/u46i Size of Lot ; acres Type of Structure Proposed )iAIGL f'f9�I/CY El ESI DE�C'.� # BEDROOMS # LOFTS C, # GARBAGE DISPOSALS /, # DISHWASHERS #, CLOTHES WASHERS 1. /% Water SuPPIY� Private Well, Spring, Stream, or X System (Public or Private Name: 5_'U>H (rl`EK VIA .�lUQGdM/}SS� IS PROOF OF ADEQUATE WATER ATTACHED? () YES or () NO HAS THIS PROJECT BEEN APPROVED BY PITKIN COUNTY? YES or () NO Application for an individual selvage disposal system permit is hereby submitted. The undersigned acknowledges that the above information is true and that false Information will invalidate the application and a,y subsequa.nt permit Issuance of the permit does not explicitly or implicitly imply the approval of any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken ,.¢;til all approvals and permits have been obtained. The owner assumes all responsibilities in case of failure or inadequacy of this system. SIGNATURE OF APPLICANT GG'L'fe/ 4 `�'•� ✓e-' ( gG l Date 1719'1 The application becomes invalid 120 d s from the date signed. This Permit is valid only for the design as specified below. trR,rrr,r*+�x•••*••*••*••*•••BELOW FOR OFFICE USE ONLY:••••*:�;••�•'j��:••"•••*••••:�. INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT # 00(/ $150 fee paid ( Yes. Date received —� 1 Receipt # (-X) l 5� Received By 6` \ DESIGN CRITERIA OF SYSTEM TO BE INSTALLED: Any changes must be submitted and approved in writing.' r of Bedrooms: _L[_, Percolation Rate: 4Z mpi, Average Daily Waste Flow: .,`,o" gallons. Is an Engineer Designed system needed? O Yes or (<No (All plans and specifications of the engineer shall be followed. Any changes must be approved in writing and the engineer shall certify the final installation to the Environmental Health Department in writing.) f,ainimum Septic Tank Capacity t S L tion Area Z.CI fou square feet minimum Z gallons Absorption {) Absorption Bed, ,Absorption Field in Trenches, Gravel -less system, ( ) Pumping/Dosing Chamber, () Absorption Pit r, ,tel --1 e S57 CA a.+ hie j S Y 1 �f ti f� f Z leech °'cages requiring inspection: O Before excavation, O Upon completion and prior to placement of gravel, O Before covering distribution system of absorption geld, () Prior to backfill of any component and any situation deemed necessary by Environmental Health Department Staff. Plans and specifications of the proposed individual sewage disposal system have been reviewed and are considered satisfactory. Permission is hereby granted to the owner of his agent to perform the work indicated above in accordance with the Pitkin County Individual Sewage Disposal Regulations in effect on the date of issue. In addition to general provisions set forth in any attachments, this Permit is subject to the following additional terms and conditions if any: i (}cam-� APPROVED FOR ISSUE BY: l DATE OF ISSUE: 10r The above individual sewage disposal system has been ins ected for use by the Aspen/Pitkin Environmental Health Department. The owner assumes all responsibilities in case of failure or inadequacy of this system. Complete as -built drawing and all specifications of as -built are included with this permit. r BY. DATE OF FINAL INSPECTION: r-INAL IN0P1Z- 111 AZ 0!19 1 :0_OTH:UDD:JTCPC:WP:PER1vIIT.G.1 130 SOUTH GALENA STREET ' ASPEN, TOLLORADRED ON C81611 1 YCLED PPHORNE 303.920.5070 ' FAX 303.920.5197 PRINA/PEHD 1/94 Nelson Environmental & Wastewater Solutions, UcL E June 3, 1994 W Mr. John Olson S John Olson Buil er, Inc. P. O. Box 10147 Aspen, CO 81612 Subject: Soils Evaluation and Percolation Test for Individual Sewage System Design for the Residence on Lot 3, Block 6, Filing I, Brush Creek Village Subdivision numbered as 72 Selma Circle Dear John, As requested, Nelson Environmental and Wastewater Solutions, Ltd., performed a soils study and percolation tests to design a septic system for the proposed residence. We conducted this study in accordance with Section 4-5 of Pitkin County Regulations on Individual Sewage Disposal stems. We have based our recommendations on the subsurface conditions encountered. We will furnish this letter to the Aspen/Pitkin Environmental Health Department in order to obtain a permit to construct this individual sewage system. Proposed Construction: The residence is to be a four bedroom, three bathroom multi-level house. There are two additional powder rooms provided in the main living area and off the media room. Site Conditions: The property is approximately 2.1 acres in size. The drinking water is to be provided from the subdivision water system through Snowmass Water and Sanitation District. The building site is on a lot located in the Brush Creek Village Subdivision. About 50% of the lot is covered with oak brush, sagebrush and grasses. The Northeastern part of the lot is sparsely vegetated with areas of decomposed shale on the surface. The ground surface, which appears natural throughout the proposed area of building and within the site of the septic system field, slopes to the Southeast at grades from 25% to 50% Subsurface Copditions: A soil profile pit, within 80 feet of the proposed absorption area, was excavated to a depth of approximately eight feet. No groundwater was encountered. Fractured bedrock was encountered at a depth of five to six feet from the surface of the ground. There was some fractured shale intermixed with the soil matrix from four feet. This bedrock became harder and more P.O. Box 6961 Snowmass Village, CO. 81615 Office (303) 923.3289 Home (303) 923.2766 Soils Evaluation and Percolation Test for Individual Sewage System Design Lot 3, Block 6, Filing I, Brush Creek Village 06/03/94 Page 2 consolidated with depth, but could still be excavated with equipment. The soils can be characterized as approximately 8 inches of silty topsoil, 42 inches of sandy clay, and 46 inches of blocky, hard, fractured shale. The vegetation pattern suggests that the soils are deeper and more prevalent along the Southwest property line, although another profile hole is necessary to establish the depth to shale bedrock within the area proposed for the septic system. The subsurface soil conditions were evaluated with the standard percolation test procedure at the approximate location shown on Figure 1. The test holes were excavated by hand . Other percolation test holes to the Northeast of the proposed absorption field location encountered fractured shale and were not able to be properly presoaked. The subsoil in which the percolation testing was run, consisted of sandy clay. These clays were well consolidated, and showed only a slight tendency to swell. The rates measured averaged 42 minutes per inch. This soil is considered acceptable for a conventional infiltration design for the on-site sewage system. However, if shallow bedrock is encountered in the proposed absorption area the soil is considered unsuitable. Should this prove to be the case, we refer you to Schmeuser, Gordon, Meyer Engineering to develop a site-specific design to address these soil conditions. Limitations: This report has been prepared in accordance with generally accepted practices in this area for use for sewage disposal design purposes. The conclusions and recommendations submitted in this report are based upon data obtained from our site visits at the location indicated. There is some possibility that the nature and extent of variations in the subsurface soils across the site may not have been evident at the time of this investigation, and may need additional evaluation if further excavation reveals conditions different from those described. This office should be advised of any unusual situations as soon as possible so we may reevaluate our recommendations. If you have questions or if we may be of further assistance, please call the office. Sincerely, Reviewed By: W Robert F. Nelson J Hammond, P.E. President Schmueser, Gordon, Me) 1 c. 10 rty WELL to ROAD ESW. COVENANTS `G. SPIKE P.O. L. USED cv- LOT 3 0 Nelson Environmental & Wastewater Solutions, L" E w TABLE I S PERCOLATION TEST RESULT FORM Hole Length Depth at Depth at Drop in Average Hole Depth of Interval Start of Interval End of Interval Water Level Percolation No. (in.) (Minutes) (Inches) (Inches) (Inches) Rate(Min./Inch) 1 35 10 107/8 10 1/8 1/2 10 101/8 913/16 5/16 10 913/16 91/2 5/16 10 91/2 91/4 1/4 10 91/4 91/16 3/16 53 2 36 10 127/8 121/2 3/8 10 121/2 121/4 1/4 10 121/4 12 1/4 10 12 113/4 1/4 10 113/4 11 1/2 1/4 40 3 35 10 55/16 5 5/16 10 5 411/16 5/16 10 411/16 4 7/16 1/4 10 47/16 4 1/8 5/16 10 41/8 313/16 5/16 John Olson, Builder, Inc. Property Lot 3, Block 6, Filing 1, Brush Creek Village Subdivision Date of Percolation Test: 04/14/94 J3 3 f Z' -IPsS k -1-C/ u z t �u 0 U L 20 2 32 P.O. Box 696. Snowmass Village, CO. 81615 Office (303) 923.3289 Home (303) 923.2766 Nelson Envirolimental & Wastewater Solutions, Ltd. E Property Address: '72 Selma Circle W Legal Description: Lot 3 Block 6 Filing I, Brush Creek Village S Subdivision Property Owner: Name John Olson, Builder, Inc. AddressP. O. Box 10147, Aspen, CO 81612 Phone 923-4233 Contractor: Excavating Contractor: Name John Olson, Builder Name Owner Address P. O. Box 10147 Address Aspen, CO 81612 Phone 923-4233 Phone Saturation and Swelling o Smeared surfaces removed X Yes o Gravel Added X Yes To a 3 or 4" Depth o Date and Time presoak water added 4/14/93 -) 9:15 a.m. o Amount of presoak water added 25 gallons/hole o Water remaining in holes after presoak? Hole 1: X Yes —No Hole 2: X Yes —No Hole 3 X Yes _ No Percolation Rate Measurement Hole 1: 53 minutes/inch Hole 2 40 minutes/inch Hole 3 32 minutes/inch AVERAGE 42 minutes/inch Groundwater: o Not Encountered at 8 ft. o Estimated depth to high seasonal water if not encountered- 180 feet o Is area believed to be subject to seasonal fluctuations which could result in a seasonal water table? Yes X No Slope in absorption area 25% to the SE Bedrock o Encountered at 6 ft. o Type of bedrock: Sandstone X Claystone X Siltstone Other: X Fractured and Weathered o Is bedrock believed to be permeable? X Yes No I certify that the above information is correct and complete to the best of my knowledge and that all tests were performed in accordance with the provisions of Pitkin County Individual Sewage Disposal Regulations, Section 4-5.1 through 4-5.7. Robert F. Nelson President Reviewed by: rnd, P.E. , Gordon, Meyer Engi P.O. Box 6961 Snowmass Village, CO. 81615 Office (303) 923.3289 Hom"( 03) X ri ASP EN/PITA.'ENVIRONM ENTAL HEALTH DEPARTMEi,. ISDS DESIGN REQUIREMENTS -DEPARTMENT USE ONLY Name SAMPLE DRAFT House Size (75 gpd, 100 gpd, or 130 gpd) #of Bedrooms, Similar Rooms accessible to baths in Main Residence # of Bedrooms, similar rooms w/ access to bath in ATTACHED caretaker # of Bedrooms & Similar Rooms w/ access to baths in DETTACHED caretaker Average Daily Waste Flow 600 # bedrooms X 2 people/br X 75 State Review Required? no 3 equals # of Perc Holes Required Perc Rate (T) Design Flo w (Q) = # bedrooms X 2 people/bedroom X gpd X 1.75 Q= 1400 Minimum tank capacity 1750 gallons Absorption Area (A= Q/5 X SQRT) A = 0 sq. ft. of absorption area required 0 infiltrator units without reduction A maximum 30% reduction is allowed for use of deep gravel or gravelless chambered system. 0 sq.ft. with reduction 0 infiltrator units with reduction AREA NEEDED FOR STANDARD ABSORPTION TRENCHES 0 0 Total sq ft /3 =lineal ft of trench needed 100 4 0 0 lineal ft/assumed trench length of 60ft = # of 60ft trenches needed -1 # trenches minus 1 = rows of 6ft wide undisturbed soil between trenches 0 0 times 3 = total width of of 60" long field needed for just the trenches 0 0 times 6' = total width of 60' long field needed just for undisturbed soil 0 width of trench +width of undisturbed soil = total width needed 0 by 60 ft is the area needed for a standard absorption field in a trench configuration with no reductions taken and ASSUMING AN AVERAGE PERCOLATION RATE OF 0 SLOWER PERCOLATING SOILS WOULD REQUIRE MORE AREA. SETBACK FROM WELL SETBACK FROM POND, STREAM OR IRRIGATION DITCH # of feet = 132 # of feet = 82 SETBACK FROM DRY GULCH # of feet = 57 Remember: 8 feet of additional distance for each 100 gallons/day of design flow over 1,000 gallons/day should be added unless an RPE can verify that it is not necessary to prevent contamination. 1/20/99 Printed on Recycled Paper