Loading...
HomeMy WebLinkAboutpitkin.eh.264321306001 (1985)ASPEN*PITKIN -26v3-a13 - a6 --oo I ENVIRONMENTAL HEALTH DEPARTMENT INDIVIDUAL SEWAGE DISPOSAL PERMIT NO. i TYPE OF PERMIT: ()()Initial Construction ( )Emergency Use ( )Repair Work#(Pievious Permit i .) ( )Alteration of an existing system, or installation (Previous Permit 1 ) ( )Use Permit as a result of Sale ( )Othort ISSUED TO: DATE OF ISSUE /o `' 17-3 — Owner AVID tL•S%O,A Home Phone 225-4,07 Business Mailing (� � /� / AddressP�, % A$pcj (� �'��� Agent�/T J Phone Mailing Address Phone Sewage Disposal System Work to be performed by. a)4,)eK!"tijteK This permit valid,,o/n�ly Qfor premises location by the following legal descriptions s Z LOT SIZE —, WATER SUPPLY (✓VjLL AVERAGE PERCOLATION RATE. 30 M1l This Individual Sewage Disposnl Permit is granted with regard to the following use: A1&1 0 AMLG.j1 S/j�t/yCE N%.r.ibcr ofr Dodreoms 13 Lofts ( Garbage Disposals 0 Dishwashers Clothes Washors / ^. CALCULATED AVERAGE DAILY WASTE LOAD o- GALLONS. —T THE Ivr', URI E OF THE SYSTEM INCLUDED UNDER THIS PERMIT: Typa of Tank or TreatmentUnits&Ar� PTIC K Tank. Capacity /zzy _Gallon H1nir¢u:a Mct.hod of Final Dispo3ala EkdGitjeeaD Absorptiop Area ,2!gJ:�E Square Feet Hininnun Description (including brand name, if any) of other equipment orIappurtnancess OF B/4&A Z Agog fr' rr 14 CP4 Ce�.' astnlG slPHopj P01-yETNj'1+�'tj lE" %i9Afi�S. .Other Conditions or Speciftcationst MotlnlD TYPE o F 1�jklC T_4 ,e &CIAJC76zs 0,47Z7_0 �D�i� s� PUE 70 �NHAaouJ &5040C'je_�. STAGES REQUIRING INSPECTION BY THE HEALTH DEPARTMENT: ( )Before Excavation Upon completion of excavation and prior to placement of gravel )before coverin-1 distribution `system of absorption field (�QPrior to backfill of any component{'(jOther, Specifys _WHr,1j ,4NQ' �J11 'A Plans and specifications of the proposed sewage disposal synteln have been reviewed and are considered satisfactory. Pernissi.on is hzreby granted to the owner or his agent to perform the work indicated above in accordance with the Pitkin County Indivi ual Sewa,;o Disposal Rcvulations in effect on the date of issue. In addition to general provisionn set fort: on LLe reverse hereei, this Permit is suhject to the following additional terms and conditions: APPROVED FOR ISSUE BY (title) The r,,x)ve in.iivldual acticago disposal system installed by — h.is boon in::pected for use by a representative of the Aspei 111t in Lnvironc�nta itcalt.. Deparunent. The .,,nor a30iwT.oa ATi rv::ponnibility in case of 311 re or inadequacysewage of th u disposal system. Complete as -built drawing attached. �I�TI�L io�31S3 .� DATE OF 'INAI. IN'PE ION j ✓ BY: TITLE &II-tl C%tiC_ Cc, pww) #Ja f �� `130 SdCsth (3blene'street Aspen, Colorado 81611 303/925-2020 ASPEN*PITKIN ENVIRONMENTAL HEALTH DEPARTMENT APPLICATION FOR AN INDIVIDUAL SEWAGE DISPOSAL•PERMIT Name of OWNER Address of OWNER Y IJ PHONE (0 -1 /° Name of APPLICANT � A�' � t PHONE PERMIT TO BE: ( )Picked Up - h)L)Mailed tot TYPE OF PERMIT: (New Installation ( )Repair (, Owner ( )Applicant )Emergency Use ( )Alteration NOT due to failure tOCATION OF PROPOSED SYSTEM: Legal Description p Lot Block - filing subdivisionAKO� EJL Size of Lot ' acres TYPE OF STRUCTURE: ()()s ngle Family Dwelling ( )Other: re you plan any further additions to the Q�� �� residence? ( )YES v a NO No, of bedrooms �°{'( o. of Lofts No. of Garbage Disposals 1_ No. of Automatic Dishwashers go. of Automatic Clothes washers i WATER SUPPLY: (t?� Private well, Depth 1� or ( )Public, Name of System ` )Spring ( )Strear+ or Creek TYPES OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED: (.)Septic Tank/Absorption Field ( )Aeration Plant/Absorption Field ( )Composting Toilet ( )Incineration Toilet ( )Mound (')Recycling, potable use ( )Recycling, other use ( )Vault Privy ( )Other: The initial site inspection must be arranged with the Aspen/Pitkin Environmental Health Department (925-2020, 8:30-9:30 a.m.) before a permit can be issued. The individual sewage disposal permit must be issued before a building permit can be obtained. FINAL INSPECTION APPROVAL MUST 13E GIVEN BY THE ASPEN/PITKIN ENVIRONMENTAL HEALTH DEPARTMENT PRIOR TO BACKFILLING ANY PORTION OF THE SYSTEM. Application for an indiviOVN sewage isposal permit is hereby submitted. The undersigned acknowledges that the above information is true and that false.i f r Cion 1 1 date the application and any subsequent per it Signature of Applicant A A DATE (This application becomes. invalid 12 months from the above date.) NOTE: PLOT PLAN must be filed with this application. Please locate the following items by measured distances: 1. Property lines and dimensions. 2. Proposed and existing water wells on subject property and adjacent property. 3. Domestic water service lines. <. Proposed and existing buildings, driveways, and other structures. S. Streams, lakes, ponds, irrigation ditches, and other water courses. 6. Proposed and existing individual sewage systems on subject property. , SUBMIT A REVISED PLOT PLAN PRIOR TO CONSTRUCTION IF INSTALLATION IS TO BE CHANGED FROM ORIGINAL PLAN. The undersigned hereby acknowledges receipt of t s individual sewage disposal pem1 a 11 tion and a permit f n the amount of S 1�L! (t , 'Receipt Number r' Date Fee Received ,z r by �C ` Administrative officer 130 SOlith-Galenn StreetAspen, Colorado*81611 303/925-2020 Dp, I vc ` 1 L -D C ATr o N —� op 400) sC V "1 ' Mo)�JD OF -SA►J D LEM « �t 11000 GA t-l,.ofll Brtr o p�L,►E�,r, s wtoo4 ANo e m M s& -g - A VEL 0 ME I Wright Water Engineers, Inc. DENVER OFFICE 2490 West 26th Ave., Suite 55A Denver, Colorado 80211 (303) 480-1700 Dave Elston Box 10391 Aspen, CO 81612 TULSA OFFICE 707 South Houston, Suite 302 Tulsa, Oklahoma 74127 (918) 584-7136 October 11, 1985 Re: Elston Wastewater Treatment System Dear Dave: wo GLENWOOD SPRINGS OFFICE 818 Colorado Avenue P.O. Box 219 Glenwood, Springs, Colorado 81602 (303) 945-7755 Denver Direct Line: 893-1608 Attached herewith is the design criteria for a wastewater treatment system for your proposed residence in Brush Creek Village. The design concept utilizes a septic tank and drainfield. The drainfield is a mound type soil absorption system that is elevated above the natural ground in a suitable fill material. This system is used because of the shallow permiable soil zone above creviced or porous bedrock. The following ar the design parameters t2� 'OF& Single famihy €mT- bedroom home Infiltration rate of natural soils 0.5 Porous or creviced bedrock less than 4 Water table greater than 4 ft. deep Design flow rate = 150 gpd per bedroom Ground slope less than 12% Septic Tank used in the system design: apd/ft2 ft, deep The septic tank shall be a concrete tank with a 1,000 gallon liquid capacity to provide a minimum of 30 hours of detention. Pre -cast tanks such as those manufactured by Copeland Concrete, Inc. in Rifle, Colorado, are acceptable. 0 Dave Elston 10/11/85 Page 2 Soil Absorption Mound NoI The soil absorption system shall be a mound type as shown on the attached Figure 7-10 and figure 7-11. The mound shall be located on natural ground, approximately parallel to the contour of the land on a slope no greater than 12%, as shown on figure 7.12. Topsoil shall be plowed or raked with backhoe teeth prior to placing the mound fill. Fill material shall be a medium textured sand, with characteristics as given in table 7-8, a copy of which is attached. Absorption bed material shall be porous media consisting of rock fill sized between 3/4"-2-1/2". Fill material and absorption bed material are available from local sand and gravel suppliers. All materials and installation practices shall comply with applicable Pitkin County standards. Mound dimensions for your system are as shown below. Refer to figure 7-13, (A) cross section and (B) plan view for location of dimensions listed: A = 10 ft. d = 50 ft . D= 1ft. E = 2 ft.(') F = 9 in. u= 1ft. H = 1-1/2 I=16ft.M* J = 7 ft.0 ) K = 12 ft. L = 74 ft. W = 33 ft.(1 NOTE: (1) Based on 10% slope will vary depending on actual slope in field. Dave Elston 10/11/85 Page 3 We suggest that the septic tank and soil absorption mound be installed by a contractor experienced in the practice of installing these systems. If you have any questions, or need any additional assistance, please call me. Very truly yours, WRIGHT WATER ENGINEERS, INC. By Paul ussone, P.E. PSB:jch Attachments 851-074.000 0 4 FIGURE 7-10 TYPICAL MOUND SYSTEMS Straw, Hay or Fabric Cap Distribution Lateral Fill k'-- -1 Ab t' B d Topsoil ----------- --' - 3 Plowed Layer of Top Soil :SIE ope =: �= Rock Strata or mpermea le Soil Layer;`_= — — (a) Cross Section of a Mound System for Slowly Permeable Soil on a Sloping Site. Cap Straw, Hay or Fabric Distribution Lateral Fill. -- Absorption Bed Topsoil Plowed Layer of Top Soil C� FIGURE 7-11 E DETAILED SCHEMATIC OF A MOUND SYSTEM Layer of Straw or Marsh Hay Sandy Loam Soil j Inlet Pipe Clean Rock Sand 1'/0" Perforated Laterals Diversion for Surface Water 6" Topsoil yer • �'`�,J :l- : -: Slope --- Broken Up' �'"_� Fill Material E TABLE 7-8 COMMONLY USED FILL MATERIALS AND THEIR ESIGN INFILTRATION RATES (24) Characteristicsa Design Infiltration Rate gpd/ft2 Medium Sand >25% 0.25-2.0 mm 1.2 <30-35% 0.05-0.25 mm <5-10% 0.002-0.05 mm � goo Sandy Loam 5-15% Clay Content 0.6 Sand/Sandy Loam 88-93% Sand 1.2 Mixture 7-12% Finer Grained Material Bottom Ash - 1.2 `rem, C .30- 35 5-lp �o 'Lo0 J Gi. FIGURE 7-12 PROPER ORIENTATION OF A MOUND SYSTEM ON A COMPLEX SLOPE Mound Shaped to Conform to the Contour and to Shed Runoff Avoid Concave Slopes to Prevent Convergence of Flow 42 FIGURE 1-13 MOUND DIMENSIONS Straw or Marsh Hay Perforated :Clay Fill or Medium Sand Fill Pipe Topsoil H G Topsoil F' 3 �E D , opsoilr u �.. 1%Slope Subsoil Plowed Surface 3/-21/2 in. Rock (A) Cross Section W (B) Plan View 247 L VvWE Wright Water Engineers, Inc. DENVER OFFICE 2490 West 26th Ave., Suite 55A Denver, Colorado 80211 (303) 480-1700 Mr. Dave Elston Box 10391 Aspen, CO 81612 CHEYENNE OFFICE 3130 Henderson Drive Cheyenne, Wyoming 82001 (307) 638-9261 October 17, 1985 Re: Elston Wastewater Treatment System Dear Dave: GLENvt'OOD SPRINGS OFFICE 818 Colorado Avenue P.O. Box 219 Glenwood, Springs, Colorado 81602 (303) 9.15-7755 Denver Direct Line: 893-1608 At•nnrdh I:. WrI%;h; William L. Lorah Richard D lohn,o, Frank 1. Irelc,uo Leo M. Lowl This is an addendum to our original letter, dated October 11, 1985, for the purpose of addressing the comments and concerns of Mr. Nelson, the Pitkin County Sanitarian. The septic tank shall be equipped with a siphon dosing capability as recommended by Mr. Nelson. Pre -fabricated tanks with built-in siphons are available in 1,000 gallon capacity to meet this requirement. The absorption mound shall have four distribution laterals, 1-1/2" diameter, 28" O.C. served by a 2" diameter manifold. The manifold shall enter the absorption bed at or near the centerline of the long axis. (dimension B) The septic tank shall be within 50 feet of the absorption mound, and the outlet shall be four feet higher in elevation to provide a minimum head at the end of the distribution pipes of 2 ft. A sieve analysis shall be run on the fill material to assure that it meets the standards specified in table 7-8. We recommend that you have all phases of the tank and mound installation checked and approved by the Pitkin County Sanitarian during construction. Very truly yours, WRIGHT WATER ENGINEERS E y maul S. Bus sone, P. E. PSB:jch 851-074.000 0 i Wright Water Engineers, Inc. DENVER OFFICE 2490 West 26th Ave., Suite 55A Denver, Colorado 80211 (303) 480-1700 Mr. Dave Elston Box 10391 Aspen, CO 81612 TULSA OFFICE 707 South Houston, Suite 302 Tulsa, Oklahoma 74127 (918) 584-7136 October 28, 1985 Re: Elston Wastewater Treatment System GLENWOOD SPRINGS OFFICE 818 Colorado Avenue P.O. Box 219 Glenwood, Springs, Colorado 81602 (303) 945-7755 Denver Direct Line: 893-1608 Dear Dav This is 4n addendum to our previous treatment system design presented in our letters datea October 11 and October 17, 1985. We have re -designed the absorption field distribution piping to utilize the standard 4" diameter perforated draintile available locally. The absorption mound shall have three distribution laterals which shall be 4" diameter PVC perforated draintile, spaced at 36" O.C.. The pipe from the dosing tank to the drainfield shall be 4" diameter PVC. The dosing tank shall be within 50 feet of the absorption mound, and the outlet shall be a minimum of three feet higher than the absorption bed. All other specifications shall remain the same. Very truly yours, WRIGHT WATER ENGINEERS, INC. By I,-�PE une . PSB: jch 851-074.000 WWE Wright Water Engineers, Inc. DENVER OFFICE 2.390 West 26th Ave., Suite 55A Denver, Colorado 80211 (303) 480-1700 TULSA OFFICE 707 South Houston, Suite 302 Tulsa, Oklahoma 74127 (918) 584-7136. January 14, 1986 Pitkin County Building Dept. bob i-4elson, County Sanitation 517 E. Hopkins Ave. Aspen, CO 81612 Re: Dave Elston - Wastewatr absorption mound Dear Gob - P GLEN VOOD SPRINGS OFFICE 818 Colorado Avenue P.O. Box 219 Glenwood, Springs, Colorado 81602 (303)945-7755 Deriver Direct Line: 893-1608 ursuant to Pitkin County Building Code requirements we are submitting this letter to verify the installation of the septic tank, dosing chamber and absorption mound on the Dave Elston property in Brush Creek Village. The absorption mound system was designed by Wright Water Engineers and installed by a private contractor under the supervision of Mr. Elston. Wright Water Engineers aid not observe the installation but did make a field inspection of the site on November 22, 1985 after completion of the installation. The size and location of the absorption field is as specified and the mound was covered with straw. At the time of inspection the mound was not covered with topsoil. The location of the field with respect to the septic tank and dosing chamber is in accordance with the recommendations in our letter Bated October 28, 1985. The septic tank and dosing chamber are separate precast fiberglass tanks. The 4" diameter pipe from the dosing chamber to the absorption mound is as specified. �•lound construction, bedding material and distribution laterals were covered and therefore could not be inspected. If additonal information is required please contact us. Very truly yours 'wRIGHT WATER ENGINEERS, INC. Paul S. Bussone, P.E. ,,ave lston PS3/ Cdr; ,'1'_—U 7`e ,r000