HomeMy WebLinkAboutpitkin.eh.264321401007 (2001)Pitkir -ounty Environmental Health Departm ^*
Pern or an Individual Sewage Disposal % ri
130 S. Galena St., Aspen, Colorado 81611
Phone 970-920-5070 / FAX 970-920-5074
Permit # 01044 Parcel ID # 2643-214-01-001
Type of permit New( x) Repair( ) Addition to House( )
Name of Owner Karl Larson
Street Address Upper Ranch Road t I
Property legal description Lot 4 Block 1 Filing 2 Brush Creek Village
Size of lot 2.142 acres Total square footage of the house 5750 sq ft
Water source Brush Creek Metro District
# of bedrooms in house 5 # of offices, lofts & similar sized rooms in house
Caretaker unit N/a Total square footage of the caretaker unit
# of bedrooms in caretaker unit # of offices, lofts & similar sized rooms in caretaker unit u�
Designed for what # rooms (list) 5 bedrooms
Permit information
Designed by Church and Associates — Tim Petz
Mailing Address 4501 Wadsworth Blvd, Wheat Ridge, CO 80033
Perc rate 32 Profile hole depth 6 ft Depth to groundwater or bedrock 6ft Q' �3
Minimum Septic tank capacity 2188 gallons Minimum Absorption area 138 -6 -sq ft w/30% reduction
r`nmmnn4c
Septic permit approved per compliance with the engineer design and specifications dated June 14, 2001. Any
changes must be approved by this department and the design engineer prior to them being made.
Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin
County ISDS regulations. The engineer has made a statement to reduce the setback from 85 feet to 25 from the
drainfield to the dry gulch. "Based on subsurface conditions, pressure dosing of the drain field, proposed imported
sand filter material and depth of imported sand filter material, we believe the setback distance to the dry gulch can
be reduced to 25 feet."
The system design calls for one 1500 gallon single compartment tank followed by one 1000 gallon two
compartment tank with dual effluent pumps in the second compartment. The field will consist of 4 gravelless
chamber beds, each bed with 2 rows of 8 chambers for a total of 96 units. Beds will be angled using 15 degree
Infiltrator Contour wedges to allow for the couture of the land. With bedrock at 6 feet, 4 feet of sand must be
imported for the field. The sand must conform to Section 12-5 of the Pitkin County ISDS regulations and an
invoice to document the sand material must be submitted.
This department does not endorse any brand of products. The engineer must do a final inspection of the
installation and submit an as -built letter to this department. This department must also be called for an inspection
with a minimum of 48 hours advanced notice.
Permit approved by: C �IC� �'C t'� W C !-� Date: '
Plans and specifications of the proposed individual sewage disposal system have been reviewed and are considered
satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin
County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was
issued unless system construction has commenced or an extension has been approved in writing by the Department.
As -built drawing must be in luded ith this permit before the final app oval will be issued.
Installer:
Finale inspection approval: Date: l�
utid1>�rit� �sl�t��z C% L4 C� �-a� Vl
Jun 25 01 11:50a Pitkin Co Env. Health (970)920-5077
Aft.
PITKIN COUNTY ENVIRONMENTAL HEALTH DEPAR i oRENT
APPLICATIONFOR INDIVIDUAL
10, DISPOSAL
0STEM
0405 Castle it AspenCoorado 81611
Phone 970-920-50701Fax 970-920-5077
Name of OWNER
Owner's Mailing Address
Business Phone. Home Phone qG3 poll
Primary Contact Person (all communication regarding this permit will go through this person)
Name
Comp *A -
Contact Mailing Address lop b }o
Business Phone : `7 V Cell 'hone: '7—'
Fax: 92 %- 91x76
parcel to # (available from assessor's office
at 920-5160 or at wvvw.aspon.com/assessor(}
Street address of property Ui P to
z 6 1— 3 z r 4_ o o o I
"AY2
_
Legal Description: Lot ,Block Filing 2 ,Subdivision r5"Ily
Size of lot: 1 ♦2 acres. Type of proposed structure: Size of bldg, envelope
Total square feet of house
s7 S D # of bedrooms in house S
# of offices, lofts &similar sized rooms in house �
Caretaker Unit: Attached ( ) Detached ( )
Of
akar unit #C
�itaL r� irk b
1.70
Total area(sq. ft.) of caretaker unit
r___ i_a.. —A cbnBOr Gi7e moms of caretaker unit
Permit is for: New Home (X) Repair due to failure ( )
RemodellAddition ( ) Emergency use ( )
Water: Private well ( ) Spring ( ) Stream { ) Community/Public Water System (y�
if community sy/S/LLlsti M&Tty 0r5j-y2-1 Gi
p.4
I
The fee for a ISDS application 5 $330�r lebeich�ged. The maximum fee t that takes 6 hours or less is $1000. The basr the department ic fee of $330 s due vat takes
he time
longer than 6 hours, a rate
of application. The remainder, if any, will be due in two stages: first, at the time of issuance of the ISDS permit; Second, before
final approval of the ISDS permit.
Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above informationlntaucis ue and
accurate and that I have provided true and accurate information on locations of all existing and proposedinns,
intervals, buildings, property lines, ditches, slopes, waterlines, springs,lches, and exion or sting g sept c systems. ation lines, eI herebye certify in
tiles, irrigation ditches, lakes, water courses, streams, floodplains, dry g
that any such features not
for construction pursuant to Pitkin ap Countyprese notecodes. No constructnt- issuance of the ion may b su dtertakenimply huntilall vat of
any other permit required
approvals and permits have been obtained.
The Aspen/Pitkin Environmental Health Department, Pitkin County and employees of these agencion es will be held harmless
should the individual sewage disposal system fail or malfunction) The permit
ii case o constro failures
system submitted by
the applicant or his/her representatives. The t►wrte a
Date Z'
Signature of applic
Receipt # � Date
Received by
d
Pitkin County Environmental Health Department
Contact Log Sheet
nancy Bailey, pre- CO
To: nancy Bailey <nancyb@ci.aspen.co.us>
From: Nancy MacKenzie <nancym@ci.aspen.co.us>
Subject: pre- CO
Cc:
Bcc:
Attached:
Not okay for Karl Lat=, 0111 Upper Ranch Rd
Don Ice called. He didn t leave a phone number. I tried the number in the phone book for him and got a
fax machine!
So if he calls you, please tell him that he is not okay with EH. We need the �g-built' letter from the engineer
before we can final his permit and before we can sign -off on his CO.
(Thanks, Nancy!)
2-A / 9 A�4� o --
Printed for Nancy MacKenzie <nancym@ci.aspen.co.us>
1
4 1 w
4
CHURCH & Associates, Inc.
ENGINEERS & GEOLOGISTS
December 3, 2002
Palomino Barth Architects, Attn: Bruce Barth
P.O. Box 301
Basalt, Colorado 81621
Subject: Installation Observation, Proposed Larson Residence
Lot 4, Block 1, Filing 2, Brush Creek Village
Pitkin County, Colorado
Job No. 13491W
Mr. Barth,
As requested, we observed the installation of the onsite wastewater system (OWS) for the subject site on
August 7, 2002 and August 14, 2002. The system was designed under our Job No. 13491W, dated June
14, 2001.
The system includes the installation of a 1500 -gallon, single -compartment, precast concrete septic tank
followed by a 1000 -gallon two-compartment precast concrete septic tank with a duplex effluent pump in
a Biotub6m pump vault in the second compartment. Four pressure -distributed chamber -beds with four -
feet of imported `Pitkin County ISDS Sand' was installed. Each bed had two rows of eight chambers for
a total area of 1488 square feet. An as -built drawing is included as Figure 1.
The pumps and alarms were installed at the time of our site visit. The construction foreman, Don Ice with
All Season Builders, may activate pumping system at his discretion. The components of the OWS were
installed in conformance with our plans and specifications.
If there are questions or if we may be of further service, please call.
Sincerely,
CHURCH &Associates, Inc.
Timothy R. Petz, Project Manager
a cb�r��
Reviewed by
13172
/2
Edward O. Church, P.E.
TRP/erb RECEIVE®
2 copies sent
Copy sent and faxed to PCEHD, Attn: Carla Block DEC 0 5 20 02
Copy faxed to All Season Builders, Attn: Don Ice, 970-963-2478
RiTKfN COUNTY
ENVIRONIMENTAL HEALTH
DENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 80033 ,,� �► i 0111
303.463.9317 Fax: 303.463.9321
.. .
LOT 4 'BLOCK 1, FILING 2
BRUSH CREEK VILLAGE
PITKIN ,COUNTY, COLORADO /
�FILTRATIVE AREA IN 4 GRAVELLESS
)S WAS INSTALLED WITH 4 FEET OF
ONE 1500-G4Y ISDS SAND. EACH BED HAS 2 ROWS
SINGLE-COMPRS FOR A TOTAL OF 96 CHAMBERS.
CONCRETE SEE PRESSURE DISTRIBUTED.
FOLLOWED B"
TWO-COMPAR
CONCRETE SE
DUAL EFFLUE
SECOND COME
5B
RE�
SCALE
1"=40'
JOB NO. 13491W 12/03/02
- FIGURE 1
ASPEN/PITKIN ENVIRONMENTAL HEALTH DEPARTMENT
ISDS DESIGN CALCULATIONS
Owner's Name
Parcel ID #
House Size (sq. ft.) MEN (75 gpd, 100 gpd, or 130 gpd) 100
Number of Bedrooms in Main House
Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House
Number of Bedrooms in Detached Caretaker unit
Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit
(If the caretaker unit is ATTACHED, treat as if part of main house.)
Average Daily Waste Flow 1000
State Review Required? no
Perc Rate (T)
Design Flow (Q) = # potential bedrooms X 2 people/bedroom X gpd X 1.75
Q= 1750
Absorption Area (=Q/5 X SQRT perc rate)
A = 1979.899 sq. ft. of absorption area required
128 gravelless chamber units without reduction
# of Perc Holes Required: 3
1 in every soil type? Spaced uniformly over proposed area?
A maximum 30% reduction is allowed for use of deep gravel or gravelless chambered system,
only if the lot size and soil conditions are optimal.
If a reduction is being proposed, describe why lot size and soil conditions are optimal:
A = 1385.9293 sq.ft. w/30% bed reduction 989.949494 sq.ft. w/ 50% trench reduction
89 gravelless chamber units 64 gravelless chamber units
Type of system: []Absorption trenches []Absorption bed [] Graveness chambers
[]Dry well []Seepage Pit []Other (type)
Minimum tank capacity 2187.5 gallons
SETBACK FROM WELL
# of feet = 160
SETBACK FROM POND, STREAM OR IRRIGATION DITCH
# of feet = 110
SETBACK FROM DRY GULCH
# of feet = 85
Printed on Recycled Paper
ASPEN/PITKIN ENVIRONMENTAL HEALTH DEPARTMENT
ISDS DESIGN CALCULATIONS
Owner's Name I .fir: Parcel ID #���
,. .
House Size ftp_ (75 gpd, loo gpd, or 130 gpd) X100
Number of Bedrooms in Main House
Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House ti
Number of Bedrooms in Detached Caretaker unit
Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit
(If the caretaker unit is ATTACHED, treat as if part of main house.)
Average Daily Waste Flow 1000
State Review Required? no
Pen Rate vows �' z �': (r)
Design Flow (Q) = # potential bedrooms X 2 people/bedroom X gpd X 1.75
Q= 1750
Absorptior Area (A= Q/5 X SQRT)
A = 1980 sq. ft. of absorption area required
128 infiltrator units without reduction
A maximum 50% reduction is allowed for use of deep gravel or graveness chambered system,
only if the lot size and soil conditions are optimal.
If a reduction is being proposed, describe why lot size and soil conditions are optimal:
USING SAND FILTER MATERIAL AND DOSING TRENCHES
A = 1386 sq.f L with reduction
89 infiltrator units with reduction
Type of system: []Absorption trenches GAbsorption bed (X] Gravelless chambers
QDry well oSeepage Pit 00ther
Minimum tank capacity 2188 gallons
SETBACK FROM WELL
# of feet =
SETBACK FROM POND, STREAM OR IRRIGATION DITCH
# of feet =
SETBACK FROM DRY GULCH
# of feet = 25 FEET WITH JUSTIFIED REDUCTION
FINAL INSPECTION I Y: DATE:
Engineer's Submittal for Septic Permit in Pitkin County
4
Owner's Last Name: LARSON Location• LOT 1 FILING 2 BRUSH CREEK
Summary of information regarding new septic system:
Type of system being proposed: GRAVELLESS CHAMBERS
Other treatment processes being used: EFFLUENT FILTER
Does the system use any mechanical parts? (Prohibited unless there is no alternative)YES
If yes, explain why there are no alternatives OWS NEEDS TO BE DOSED
Does the system require any maintenance other than routine pumping? YES
If yes, who will do the maintenance? CLEAN FILTER WHEN SEPTIC TANK IS PUMPED
Are any reductions being proposed? YES
If yes, what makes the lot and soil conditions optimal?
PROPOSING SAND FILTER MATERIAL AND DOSING BEDS
Which of the following are on the site or within setbacks?
Closest distance of septic system to each feature
0 100 year floodplain
NLA
0 well(s)
N/A
0 irrigation ditches
N/A
0 streams
N/A
0 ponds -- J
N/A
O DRY GULCi
25 FEET
What was the profile hole depth? 6 FEET
What is the depth to groundwater? N/A
What is the depth to bedrock? NLA
What assumptions, if any, were made in system sizing and design? (Include any local, site-
specific data, such as months without snow cover, ratio of evaporation to absorption, etc. that are
relevant.)
If there are any variations from normal design, please explain how they can be demonstrated to
improve treatment and protect water quality. NONE
Sub, Dce Investigation and OWS Design
Job No. 13491W
Page 3
If there are questions or if we can be of further service, please call. The project engineer is Tim Petz.
Sincerely,
CHURCH & Associates Inc.
L.
Edward O. C]
EOC/trp/erb
3 copies sent, via Fed Ex, Bruce Barth
174 Mdland Avenue, Apt 205
Basalt, CO 81621
CHURCH & Associates, Inc.
ENGINEERS & GEOLOGISTS
June 14, 2001
Palomino Barth Architects
Attn: Bruce Barth
P.O. Box 301
Basalt, Colorado 11621
Subject: Subsurface Investigation and OWS Design, Proposed Larson Residence
Lot 4, Block 1, Filing 2
Pitkin County, Colorado
Job No. 13491W
Mr. Barth,
As requested we have investigated subsurface conditions and designed an onsite wastewater system (OWS)
for the proposed residence at the subject site. Our office conducted the subsurface investigation on May 19,
2001.
SITE CONDITIONS
The lot is located in a rural residential area in Pitkin County, Colorado. The proposed drain field area is
located on a steep slope of 25%-35%. There is a thin cover of scrub oak and grasses in the proposed field
area. This is the most suitable location for the drain field. Water will be provided by the local water district.
PROPOSED CONSTRUCTION
A five -bedroom residence with 4500 square feet (SF) of living area is proposed at the location presented on
Figure 1. The OWS was based on 5 bedrooms and 1000 gallons per day (GPD) using Aspen/Pitkin Envir-
onmental Health Department (APEHD) loading of 100 gallons per day per person. The sewage loading
with a peaking factor of 1.75 is 1750 GPD. This loading includes washing machines and garbage grinders.
SUBSURFACE CONDITIONS
A subsurface investigation was conducted by digging one profile pit and three percolation holes, 12 to 15
inches deep, as indicated on Figure 1. Subsurface conditions consisted of 6 inches of sandy topsoil,
underlain by highly fractured Mancos shale bedrock to the maximum explored depth of 6 feet. Percolation
tests indicate percolation rates of 27 to 40 minutes per inch (MPI), with an average percolation rate of 32
MPI. Percolation data is presented in Figure 1.
DENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 80033 CASTLE ROCK 303.660.4358
303.463.9317 Fax: 303.463.9321 EVERGREEN 303.816.1455
LOVELAND 970.663.2124
Sul ace Investigation and OWS Design
Job No. 13491W
Page 2
RECOMMENDATIONS
The installation must include two septic tanks with dual effluent pumps and four chamber -bed drain fields
with imported sand -filter material, at the locations presented on Figure 1. The OWS design is based on an
average sewage load of 1750 GPD and a percolation rate of 32 MPI. The installation must include one
1500 -gallon, single -compartment, precast concrete septic tank followed by one 1000 -gallon, two-
compartment, pre -cast concrete septic tank with dual effluent pumps in a Biotube® pump vault and four
chamber -beds with four feet of imported sand filter material. Sand specifications must be followed as
indicated on Figure 2. Each bed must have 2 rows of 8 chambers for a total of 96 chambers. Pumps with a
total flow rate of 29.5 Gallons Per Minute (GPM) and a Total Dynamic Head (TDM of 19.9 feet are
required to pressurize the distribution system at the field. The beds are to be angled to match the contour of
the slope using 15 degree InfiltratorTM Contour® Wedges. Several contour wedges may be used if angles
greater than 15 degrees is required.
Based on a. subsurface conditions, b. pressure dosing of drain field, c. proposed imported sand filter
material, and d. depth of imported sand filter material, we believe the setback distance to the dry gulch can
be reduced to 25 feet. The resultant flow from the drain fields will not be directed towards dry gulch.
Vehicle movement over the drain field area during construction should be kept at a minimum to
minimize compaction of the receiving soils. The bottom of the bed should be scarified with a pick,
shovel, or backhoe bucket teeth prior to the addition of dispersal gravel.
The surface of the drain fields should be re-established to approximate the natural slope and then be
reseeded. We recommend using a native seed mix. These mixes do not require irrigation and develop a
growth 10 to 15 inches high. No automatic sprinkler system should be installed over the fields.
OPERATION AND MAINTENANCE
The owner must realize an OWS is different from public sewer service. The owner must be aware of
and assume responsibility for continued maintenance of the system. In the absence of a monitoring
program, we recommend the septic tank be pumped every two years. Effluent filter and screened
vaults, as applicable, are to be cleaned during the regular tank pumping. There are daily considerations
such as not putting plastic or other nonbiodegradable materials into the septic system. Garbage
disposal use should be minimized.
The backwash of a water softener may be harmful to the OWS. A separate drywell should be constructed
for the backwash waste, if a softener is installed. Chemically treated water from a swimming pool or spas
should not be introduced to the OWS.
LIMITATIONS
A contractor who is experienced in OWS installation should install the OWS design. Our investigation,
layout, design and recommendations are based on data submitted. If subsurface conditions considerably
different from those described in this report are encountered, we should be notified to evaluate the effect on
the proposed OWS. If the health department makes modifications to this design, we should be contacted to
evaluate the impact on the performance of the OWS. The county and our firm must be contacted upon
completion of the OWS.
LOT 4, BLOCK 1, FILING 2
BRUSH CREEK VILLAGE .�
PITKIN COUNTY, COLORADO
ONE 4500 -GALLON,
SINGLE -COMPARTMENT, PRECAST
CONCRETE SEPTIC TANK
FOLLOWED BY ONE 1000 -GALLON,
TWO-COMPARTMENT, PRECAST-----�-
CONCRETE SEPTIC TANK WITH
DUAL EFFLUENT PUMPS IN THE l
i SECOND COMPARTMENT.
f 1
1
P`
PROPOSED 5 PRO
BEDROOM
RESIDENCE T
2 1lit
♦� QIID�
1.25° PUMP LINES
CLEANOUT
JOB NO. 13491 W
SITE PLAN, AND LOCATION OF
PERCOLOATION HOLES, AND
LOCATION OF PROPOSED OWS
SCALE
1"=40'
1488 SF OF INFILTRATIVE AREA IN 4 GRAVELLESS
CHAMBER -BEDS. EACH BED MUST HAVE 2 ROWS OF
8 CHAMBERS FOR A TOTAL OF 96 CHAMBERS. BEDS
ARE ANGLED USING 150 INFILTRATOR® CONTOUR -
WEDGES.
6/14/01
FIGURE 1
10
TYPICAL PLAN VIEW -- N.T.S.
LINE TO 3RD AND
4TH TRENCHES
MAINFOLDS LEVEL WITH
CONTOUR OF SLOPE
TYPICAL CROSS-SECTION - N.T.S.
4" SDR 35 PVC
OBSERVATION/VENT PIPE--'-----
WITH CAP
4' MAX
VT OF
VATIOM"-al-
R
SAND FILTER MATERIAL'
t0
BACKFILL
-6' MI
TOTAL FOUR BEDS
1.25" SDR 35 PVC PIPE
WITH 1/8- HOLES FACING
UP ON 3 FOOT CENTERS
(EVERY FIFTH HOLE FACING
DOWNWARD)
4 1
SANDY
TOPSOIL
1.25" SDR 35 PVC PIPE WITH
1/8- HOLES FACING UP
ON 3 FOOT CENTERS
(EVERY FIFTH HOLE FACING DOWNWARD)
4" SDR 35 PVC
OBSERVATION/VENT PIPE
kRE ANGLED USING 15'
ATOR®CONTOUR- WEDGES.
*SAND FILTER MATERIAL:
THE FILTERING MATERIAL MUST BE CLEAN, COARSE
SAND. ALL PASSING A SCREEN HAVING FOUR MESHES
TO THE INCH. THE SAND MUST HAVE AN EFFECTIVE
SIZE OF GRANULAR MEDIA SUCH THAT NOT MORE
THAN 10% BY WEIGHT OF THE MEDIA IS FINER THAN
0.6mm
CALCULATIONS AND SPECIFICATIONS GRAVELLESS CHAMBER
DESIGN CRITERIA X BY 6.25'
STRUCTURE - 5 BEDROOMS, 4500 SF
LOADING - 100 GAL/DAY/PERSON
TOTAL LOADING - 1000 GPD TRENCH SPECIFICATIONS TREATMENT UNIT SPECIFICATIONS
PERCOLATION TEST - 32 MPI NUMBER OF BEDS - 4
AREA - (1.75 X q X4 -f)/5 LENGTH OF EACH BED - 50 FEET, 8 CHAMBERS MINIMUM CAPACITY - 1.75 X q X {30 HOURS/24 HOURS) = 2188 GALLONS
AREA - 1980 SF WIDTH OF EACH BED - 6 FEET, 2 CHAMBERS RECOMMENDATION - ONE 1500 -GALLON, SINGLE -COMPARTMENT, PRE -CAST
REDUCTION FOR USE OF CHAMBERS - 30% TOTAL NUMBER OF CHAMBERS - 96 CHAMBERS CONCRETE SEPTIC TANK TO BE FOLLOWED BY ONE 1000 -GALLON,
TOTAL AREA - 1386 SF TOTAL AREA - 1488 SF TWO-COMPARTMENT, PRE -CAST CONCRETE SEPTIC TANK WITH DUAL EFFLUENT
PUMPS IN A BIOTUBETM VAULT.
DRAIN FIELD DETAILS 6/14/01
JOB NO. 13491W FIGURE 2
HURC`H R Acenr-_intAc
Duplex Effluent Pumping System
1500 -Gallon, Single -Compartment, Precast Concrete Septic Tank and
1000 -Gallon, Two -Compartment, Precast Concrete Septic Tank With
Duplex Effluent Pump In Second Compartment
Tank Adapter
(cast or bolted)
Inlet Tee
Inspection Access
Riser and Lid
Slope Ground
Away From Riser
ar_........ ".
Liquid Level
V
Fiberglass Gasketed Lid with
Stainless Steel Bolts
/PVC Riser with Grommet(s)
(bond to tank adapter with
recommended adhesive)
Vent Orifice
Disclosure: The owners of Church & Associates, Inc. also own S.C.G.
Enterprises, Inc. which distributes Orenco Systems Inc. products
-PVC Riser with Grommets—
(bond to tank adapter with
recommended adhesive)
Fiberglass Gasketed Lid witt
Stainless Steel Bolts
PVC Splice Box
with Cord Grips—
Wiring to -
Control Panel
Tank Adapter (cast or
Orenco Systems®
Incarpw*W
814 AIRWAY AVENUE
SUTHERLIN, OREGON
97479-9012
TELEPHONE:
•
(541) 459-4449
FACSIMILE:
(541) 459-2884
-- Discharge Assembly
— Flexible Hoses (2)
i
Effluent Discharge
— Level Control
Float Assembly
Check Valve
Vault Inlet Parts
Flow Inducer (2)
OSI Effluent Pump
Drain Part
Filter Cartridge
Biotube® Pump Vault
Patents # 4,439,323 & 5,492,635
Foreign Patents Pending 6/14/01
JOB NO, 13491W FIGURE 3
Pump Selection for a Pressurized System
Minimum Flow Rate per Orifice
0.43 gpm
Orifice Size
118 inches
Residual Head at Last Orifice
5.0 feet
Orifice Spacing
3.00 feet
Number of Laterals per Cell
4
Lateral Length
50.0 feet
Lateral Line Size
1.26 inches
Lateral Pipe Class/Schedule
40
Distributing Valve Model
None
Manifold Length
8.0 feet
Manifold Line Size
1.25 inches
Manifold Pipe Class/Schedule
40
Lift to Manifold
1.0 feet
Transport Length
84.0 feet
Transport Line Size
1.25 inches
Transport Pipe Class/Schedule
40
Discharge Assembly Size
1.25 inches
Flow Meter
None inches
'Add-on' Friction Losses
0.0 feet
Minimum Flow Rate per Orifice
0.43 gpm
Number of Orifices per Zone
68
Total Actual Flow Rate
29.5 gpm
Number of Lines per Zone
4
% Flow Differential 1 st and Last Orifice
1.4 %
Lift to Manifold
1.0 feet
Residual Head at Last Orifice
5.0 feet
Head Loss in Laterals
0.2 feet
Head Loss Through Distributing Valve
0.0 feet
Head Loss in Manifold
0.2 feet
Head Loss in Transport Pipe
9.1 feet
Head Loss Through Discharge
4.4 feet
Head Loss Through Flow Meter
0.0 feet
'Add-on' Friction Losses
0.0 feet
Total Flow Rate
29.5 gpm
TDH
19.9 feet
Job No. 13491W
Figure 4
Net Discharge, gpm
0 111111111111111t
Orenco System
Incorporated
814 AIRWAY AVENUE
SUTHERLIN, OREGON
97479-9012
TELEPHONE:
(541) 459-4449
FACSIMILE:
(5411459-2884
11
Profile:
TABLE 1 - PERCOLATION TEST RESULTS
Lot 4, Block 1, Filing 2, DATE OF TEST: 5/19/01
Brush Creek Village
fppt cipccrintinn
0-6" Sandy, gravelly, topsoil
6"-6' Highly weathered, fractured Mancos shale, hard, moist, grey
NO GROUND WATER WAS ENCOUNTERED WITHIN THE EXCAVATION
AVG.
HOLE DEPTH TIME DEPTH DEPTH CHANGE INTERVAL HOLE
NUMBER
OF HOLE, INTERVAL START, END, (INCHES) PERC PERC.
(INCHES) (MINUTES) (INCHES) (INCHES) RATE (MPI) RATE,
fMP11
1 13 20
2.50
4.50
2.00
10
20
4.50
5.25
0.75
27
20
1.25
3.00
1.75
11
20
3.00
3.75
0.75
27
20
3.75
4.75
1.00
20
20
4.75
5.50
0.75
27 27
3 15 20
1.25
3.00
1.75
11
20
3.00
4.00
1.00
20
20
2.75
4.00
1.25
16
20
4.00
5.25
1.25
16
20
1.34
2.50
1.16
17
20
2.50
3.25
0.75
27 27
Job No. 13491W
0
0
3
FARE
GRADATION REPORT
Lo
GO#: PIT*
85884
P ECT:
L&AUZ
SAMP
PRODUCED
PRODUCT
r
S L
BY p0 Yr
CODE:
r
Qj
SAMPLE
AGGREGATE
I ION:
LOCAT.CN: x
CLASSIFICATION:
27
j
BULK SPECIFIC GRAVITY
9 T)2'
SSD SPECIFIC GRAVITY
1'
APPARENT SP. GRAVITY
314-
ABSORPTION
3)
x
ln"
MOISTURE
z
o
3f8'
DRY RODDED UNIT WGT
k 40
V
L A ABRASI ON
GRADING
m
98 �%'
•
FINENESS MODULUS
m
A
910
SAND EGU I VALENT
00
A
#16 17 f
FRACTURED FACE
#30 •2,
S• . Z
FLATIELONGATED
#40
q50
D
100
#200
m
n
TOTAL V EIGHT: b
N
m
CD
PREPARED BY-
DATE: 7m
COMMENTS:
m
W
3
r
PLANT NO:
FOREMAN: /t71 '-.v
_ ��r
B G ' I E ' LOWER LEVEL FLOOR PLAN
(D`'3
palominobanh: ;
P.O. BOX 301
'��'°"`°"°
BASALT. COLORADO 81621BR
PHONE(970)9r-9976
FAX(970)927-9676
buoer7o Wmlmob®dL.
CARSON RESIDENCE
LOT 4, FILING 2
BRUSH CREEK VILLAGE
PITKIN COUNTY, CO
daa '�"�
jab.. M-151
Wci by .6
d e pn s e 11
&le pmveA MINI
l 1
2K-151 A2.tC7-1T-01)
1- .01 P—
-01 Pm„e s>bnal
LOWER LEVEL
FLOOR PLAN
corrwcxrenLonvloeNcnaPc
5HON4q IN THE T7RA1IN65.
MAIN LEVEL FLOOR PLAN
O 1/4'= 1'-0'
- - .,-
_
`
Palominobartharcoucct, P
P.O. BOX 301
180 Fiat Lane
BASALT, COLORADO 81621
PHONE(970)9r-9976
FAX(910)927-9676
hvoe@l.laol obWhaaa
LARSON RESIDENCE
LOT 4, FILING 2
BRUSH CREEK VILLAGE
PPTKIN COUNTY, CO
job so: 2R
BR
dmm by B12-4-00
I—Ud by BNB
d�eP®1ed 6,IIN1
A2.2
2K-751 A210-17-01;
12-4-00 PticiryS Sel
6. 41 Perth Stbnut
.W.
MAIN LEVEL
FLOOR PLAN
COPYRIGHT PALOWNO BARTH PC