Loading...
HomeMy WebLinkAboutpitkin.eh.264322301006 (2014)CouNx� 0 , iN prK Pitkin County Environmental F'- alth Department Jnsite Wastewater Treatment Syst,_.tt (OWTS) USE PERMIT Permit for Continued Use of an Existing OWTS 76 Service Center Road, Aspen, CO 81611 Phone: 970-920-5070 Fax: 970-920-5077 www.aspenpitkin.com/EHNR Parcel ID #: 2643-223-01-006 OWTS Use Permit #: I 0058.2014.POWU Date Issued: 10/31/14 Issued By: Bryan Daugherty Expiration Date: 10/31/15 Owner(s): I Michael Rosenbaum Property Address: 740 ft2 46 McLain Flats Rd� Legal Description: Lot 18, W/J Ranch Homes Licensed Inspector: Tom Zancanella Inspection Date(s): 10/7/14 SYSTEM INFORMATION Components Type Capacity/Size Primary Treatment Unit Two compartment concrete tank 1250 gallons Secondary Treatment Unit Absorption Area Dry Well 740 ft2 Other System Components OWTS Use Status: ® In use at the time of the inspection. ❑Not in use at the time of the inspection.* *If the OWTS was not in use at the time of the inspection, it is recommended that the system be re-evaluated when it is in use for a more accurate evaluation of the system. System Records: Permit #: 81065 Date of Issuance: 10/26/81 Date of Final Approval: 11/9/81 # of Bedrooms or fixtures served by OWTS: This system was designed to serve 4 bedrooms, 2 bedrooms in each duplex. Operational Status: At the time of inspection the system was working properly. The 1250 gallon tank was in good condition with tees and baffle in place. The dry well did not show any signs of failure. Inspector Recommendations: N/A Department Recommendations: We recommend adding an effluent filter to the outlet tee of the tank to prevent solids from reaching the dry well. Issuance of this OWTS Use Permit is based solely on the conditions observed and reported by the inspector to the Department on the date of the inspection(s) and on Department records at the time of permitting. The issuance of this permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail or that the system will not be subject to future enforcement action to correct non-compliant conditions. Estimated capacity of the system has been listed on the permit and we recommend that you monitor and/or meter water use to prevent overuse and possible failure. a 'AlfIrKIN Onsite Wastewater Treatment Systems (OWTS) Use Permit Inspection Form ouNTI; Pitkin County Environmental Health Department 76 Service Center Rd, Aspen, CO 81611 CID -!?*CI -141 - Phone: 970-920-5070 Fax: 970-920-5374 Website: www.aspenpitkin.com/ehnr Inspection form for continued use of an existing OWTS Owner's Name: Michael Rosenbaum Address: 5250 E. Cornell Avenue Denver, CO 80222-6824 Parcel Number: 264322301006, 46 Mclain Flats Road Inspection Date: October 7, 2014 Inspector's Name: Thomas Zancanella Business Name: Zancanella & Associates Phone Number 970-945-5700 Email: tzancanella(a)za-engineering.com Pitkin County Systems Inspector License Number: A copy of this inspection report will be remitted to Pitkin County Environmental Health Department by the Licensed Systems Inspector within 60 days of the inspection regardless of whether the system passes or fails. QUESTIONS FOR PROPERTY OWNER PRIOR TO INSPECTION: Is the home currently occupied? YES NO If NO, how long has the home been vacant? How many bedrooms are in the home? 2 If secondary treatment is used, who is the maintenance provider? RECORDS: Were system records available from Pitkin County? YES NO If YES: Permit number: 81065 Date of Final Approval: 10-26-81 # of bedrooms permitted: 4 Was an as -built drawing available? 'E$7 NO Is the as -built drawing accurate? (aD NO If NO: Complete a drawing of the system on last page of this form as accurately as possible. Any question marked FAIL will require correction before an OWTS Use permit is issued. SITE CONDITIONS: Proper grading, no evidence of erosion? PASS FAIL Improper vegetative cover? NO YES Evidence of compaction such as heavy machinery or livestock? NO YES Improper discharges such as straight pipes? PASS FAIL Evidence of high ground water? NO YES Snow cover present? N YES Page 1 TANK: Tank 1 NO Tank 2 PASS FAIL Tank 3 Tank capacity 1250 gallons PASS gallons SECONDARY TREATMENT: gallons Tank material Concrete NO UNKNOWN If YES, does the unit appear to be in good working condition? YES NO YES # of compartments 2 UNKNOWN Maintenance Provider: Phone: YES NO UNKNOWN If YES, is it accessible from grade? Date of last pumping _Mjay 2014 Is it level and in good condition? PASS FAIL Lids/risers in good condition PASS FAIL PASS FAIL PASS FAIL Risers to grade YES NO YES NO YES NO Riser height 24" Riser condition/watertightness Good Inlet sanitaryT/baffle PASS FAIL PASS FAIL PASS FAIL Outlet sanitary T/baffle PASS FAIL PASS FAIL PASS FAIL Effluent filter (if part of design) PASS FAIL N/A PASS FAIL N/A PASS FAIL N/A Condition of tank material PASS FAIL PASS FAIL PASS FAIL Tank was pumped for inspection YES NO YES NO YES NO If YES, list the pumping company If NO, when was the last pumping May 2014, B&R Septic Scum level (1st compartment) 0 inches inches inches Sludge level (1st compartment) 6 inches inches inches Scum level (2nd compartment) 0 inches inches inches Sludge level (2nd compartment) 2 inches inches inches Backflow (if pumped) PASS FAIL PASS FAIL PASS FAIL Midtank baffle PASS FAIL N/A PASS FAIL N/A PASS FAIL N/A Watertightness I ASS FAIL I PASS FAIL PASS FAIL PUMPS/DOSING SIPHONS: Is a pump or dosing siphon present? YES NO If YES, is the pump/dosing siphon functioning properly? PASS FAIL Does the pump/wiring/dosing siphon appear to be in good condition? PASS FAIL Is the high water alarm working, both visible and audible? PASS FAIL SECONDARY TREATMENT: NO YES Is a secondary treatment unit present? YES NO UNKNOWN If YES, does the unit appear to be in good working condition? YES NO YES Does the owner have a current maintenance contract for the unit? YES NO UNKNOWN Maintenance Provider: Phone: YES NO UNKNOWN If there is no maintenance contract, a contract must be in place prior to occupancy of the home. A copy of the contract must be submitted to Pitkin County Environmental Health Department. ABSORBTION AREA: Effluent surfacing? PASS FAIL Evidence of past surfacing? NO YES Surface dampness? NO YES Excessive odors? NO YES Field location verified by observation ports or probing: Ports Probing Liquid in observation port? NO YES If YES, record depth: inches Distribution Box or ADV part of original design? YES NO UNKNOWN If YES, is it accessible from grade? YES NO Is it level and in good condition? PASS FAIL Page 2 Any problems with the system that were not addressed in the inspection checklist? Please list any recommendations for the continued use of the system: Were any repairs done as a result of this inspection? NO YES If YES, please describe the repairs. To the b st of my knowledge and training, the information collected in this inspection is accurate as of G / v C/ , 20j*. Licensed Systems Inspector Signature: A1).1Aj& M,�* Additional Notes: This system has a 1250 gallon septic tank based on pumping records from B&R septic. The tank flows into a dry well that is 20 feet away. The dry well has a lid that is at ground level. The dry well is in good condition and appears to be operating properly. Clearly label any pictures and attach them to this form. Page 3 If no as -built drawings exist for this system or the as -built was inaccurate, please diagram the system as accurately as possible. Be sure to document all system components and the location of any well on the property. Using markers such as corners of the house, exact measurements can be used to triangulate Page 4 Pitkin County Environmental Health Department "11� Onsite Wastewater Treatment System (OWTS) USE PERMIT APPLICATION �Ut 76 Service Center Rd *CN4) Aspen, CO 81611 Website: www.aspenpitkin.com/ehnr/ Annlication for Continued Use of an Existina OWTS Parcel ID# (available from the Pitkin County Assessor's Office 970-920-5160 or at www.pitkinassessor.org): Purpose of Use Permit: x❑ PROPERTY TRANSACTION ❑REMODEL/AD DITION Property Address: 46 Mclain Flats Road Lot: Block: Filing: Subdivision: 18 W/J Ranch Homes Residences: Other # of Bedrooms: 2 fixtures/uses: Property Owner(s)': Email Address: Michael Rosenbaum thurman@sopris.net Owner's Mailing Address: City, State, Zip: 5250 E. Cornell Ave Denver, CO 80222 6824 Home Phone: 'C;nntact information must be Drovided for the owner sianina this application. Business Phone: Primary Contact Person/Applicant (if not owner): Company: Tom Zancanella Zancanella & Associates Contact/Applicant Mailing Address: City, State, Zip: 1011 Grand Ave Glenwood Springs, CO 81601 Cell Phone: Business Phone: 970-945-5700 Fax Number: Email Address: 970-945-1253 Indicate Preferred Method of Permit Receipt: ® Email El Fax ❑ US Mail icensed Systems Inspector: Phone Number: Email Address: Fax Number: Tom Zancenlla 70-945-5700 zancanella@za-engineering.com 970-945-1253 failing Address: City, State, Zip: 1011 Grand Ave, Glenwood Springs, CO 81601 PLEASE READ BEFORE SIGNING: I certify that the above information is complete and accurate and that I have provided complete and accurate information in all of the documents included in my application package. I acknowledge that this department may revoke any permit I am issued if my application is found to contain any inaccurate, false, or misleading information. )wner Signature (Required): Date: ,pplicant Signature: Date: Please allow 3-5 business days for processing of Use Permits. OR OFFICE USE:0N,_- .eceived by EH Staff: Fee & Receipt #: Date: 8/2/2017 Parcel Detail Pitkin County Assessor Parcel Detail Information Assessor Property Search I Assessor Subset Query I Assessor Sales Search Clerk & Recorder Reception Search I Treasurer Tax Search Search GIS Map I GIS Help Basic Building Characteristics I Value Summary Parcel Detail I Value Detail I Sales Detail I Residential/Commercial Improvement Detail Owner Detail I Land Detail I Photographs Tax Account Parcel Property Type 2016 Mill Area Number Number Levy F095 R015141 264322301006 HOUSING 75.674 AUTH Primary Owner Name and Address IDEEP DAVID J JR PO BOX 12184 ASPEN, CO 81612 Additional Owner Detail Legal Description Subdivision: W/J RANCH HOMES Lot: 18 DEED RESTRICTED Location Physical Address: 146 STEVENS ST ASPEN Subdivision: W/J RANCH HOMES Land Acres: 0.234 Land Sq Ft: 0 2017 Property Value Summary Actual Value Assessed Value Land: 100,000 7,200 Improvements: 204,800 14,750 http://pitkinassessor.org/assessor/Parcel.asp?AccountNumber=RO15141 1/3