Loading...
HomeMy WebLinkAboutpitkin.eh.264322301035 (2009)p43 -Z23 -of -p3 ✓` PO Boz 2844 111 Glenwood Springs, CO 91602 EI Ph 970-618-5033 I lv C Fax 303-216.27% February 21, 2009 ob­t� Project No. 1574 Liz Treadwell 750 Stevens Street Aspen, CO 81611 Onsite Wastewater7rrado stem Evaluation, Existing Treadwell Residence 750 Stevens StreetCOYOTE ROAD Pitkin County, Col Liz, As requested, ALL SERVICE septic, LLC performed an onsite wastewater treatment system (OWTS) evaluation on February 18th 2009 for the subject property. The homeowner is proposing to add a bedroom to the residence to bring the total number of bedrooms to three. The subject property is located in W/J Ranch Subdivision, Pitkin County, Colorado, outside of the town of Woody Creek. The subject OWTS consists of a concrete septic tank and a `drywell drain field. Pitkin County has no record of OWTS construction. OBSERVATIONS and EVALUATION B and R Septic Services used a camera and locator to help evaluate the construction, the size, and the layout of the OWTS. The subject OWTS consists of a 1250 -gallon, two-compartment concrete septic tank with PVC inlet and outlet tees. The tank was last pumped in the fall of 2008. The drain field consists of approximate 6 -ft diameter concrete perforated rings that are 12 -ft in depth. Gravel was placed around the concrete rings prior to backfill. We collected a soil sample in the vicinity of the `drywell' to evaluate the type of soil at the subject site. The gradation analysis is attached. The soil is a clean sandy loam, which has indicates an application rate of 1.3 gals/SF/day. The `drywell' has an approximate effective infiltrative area of 600 SF and a daily storage capacity of approximately 1000 gallons. RECOMMEDATIONS AND/OR CONCLUSIONS 1. The current septic tank is in good condition and has adequate capacity to serve three bedrooms. 2. The `Drywell' was observed and was completely empty and has adequate infiltrative area and storage capacity to serve 3 -bedrooms. OWS Evaluation Project No. 1574 February 21, 2009 Page 2 This evaluation is not a guarantee of any future drain field performance, in any way. ALL SERVICE septic, LLC evaluated the OWS on Feh 154 and has no further knowledge of use and/or performance, and/or any changes. Please call with questions. Sincerely, ALL SERVICE septic, LLC Timothy R. Petz, NAWT Certification No. 1060041 C 2 copies sent r APPROXIMATE LAYOUT OF OWTS pond 1250 -GALLON, TWO-COMPARTMENT CONCRETE SEPTIC TANK WITH RISERS TO GRADE o O rj 6' approx DRYWELL WITH PERFORATED CONCRETE RINGS. APPROXIMATE STORAGE AREA OF 1000 GALS, AND INFILTRATIVE AREA OF 600 SF. I �r not to scale THE LOCATION OF EXISTING AND PROPOSED IMPROVEMENTS SHOWN ARE NOT THE RESULT OF A PROPERTY SURVEY. THE LOCATIONS ARE APPROXIMATE. IT IS THE HOMEOWNERS DUTY TO ENSURE ALL CONSTRUCTION AND IMPROVEMENTS LOCATIONS ARE ACCURATE. ALL SETBACK DISTANCES SHOULD BE CONFIRMED PRIOR TO EXCAVATION. 750 STEVENS STREET ALL SERVICE SEPTIC, LLC PRO. NO. 1574 PITKIN COUNTY, COLORADO Po Box 2844, GLENW000 SPRNGs, Co 81602 TREADWELL RESIDENCE 970-618-5055 FIGURE 0 Location of Drywell. Locator from B and R Septic. Septic Tank and Drywell. Pro No 1574 OWS Evaluation Project No. 1574 February 21, 2009 Page 3 • , F ZM 0 8 r O 01 co t0 LD 0IT m N O O BU/SSed C 0 m Y L Y O 5 N C N 70 N >, o U � Z — W caw I N c. W Z) J = � d U) IL C/) 0 0 0 0 0 0 r- M N _ y r N /N mC V co LL ISDS DESIGN CALCULATIONS - for Pitkin USING LTAR Owner's Name 1 "R Parcel ID # House Size (sq. ft.) w> rc (75 gpd or 100 gpd) 75 Number of Bedrooms in Main House . Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House Number of Bedrooms in Detached Caretaker unit " fl Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit (If the caretaker unit is ATTACHED, treat as if part of main house.) Average Daily Waste Flow 450 State Review Required? no LTAR M40 (,) Design Flow (Q) _ # potential bedrooms X 2 people/bedroom X gpd X 1.5 Q= 675 Minimum tank capacity 843.75 gallons Absorption Area (-B 1.0/B17) A = Q x 1.0 loading/LTAR A = 519 sq. ft. of absorption area required nb,.eEptio Area (-Q/5 X SART ,,ere rate) 449 :144 SECOND n A= 519 sq. ft. of absorption area required Abs. Area w/ loading factor (B25) Trench Bed Quick4 Trench Quick4 Bed Pipe and Gravel 467.3076923 519.2307692 47.3 52.6 Dosing 415.3846154 415.3846154 42.1 42.1 Chambers 363.4615385 467.3076923 36.8 47.3 Max Allowable 259.6153846 363.4615385 26.3 36.8 Secondary Treatment Abs Area w/ out loading factor (B28) Trench Bed Pipe and Gravel 467.3076923 519.2307692 47.3 52.6 Dosing 415.3846154 415.3846154 42.1 42.1 Chambers 363.4615385 467.3076923 36.8 47.3 Max Allowable 259.6153846 363.4615385 26.3 36.8 100 SETBACK FROM WELL # of feet = 50 SETBACK FROM POND, STREAM OR IRRIGATION DITCH # of feet = 25 SETBACK FROM DRY GULCH # of feet =